APPROVED BLD ENG PLN BLD2021-1734+Architectural_Plan+4.28.2022_4.06.34_PM+2835137wireless.. DISH Wireless L.L.C. SITE ID: SESEA00426D SCOPE OF WORK THIS IS NOT AN ALL INCLUSIVE UST. CONTRACTOR SHALL UTILIZE SPECIFIED EQUIPMENT PART OR ENGINEER APPROVED EQUIVALENT. CONTRACTOR SHALL VERIFY ALL NEEDED EQUIPMENT TO PROVIDE A FUNCTIONAL SITE. THE PROJECT GENERALLY CONSISTS OF THE FOLLOWING: SECTOR SCOPE OF WORK: • INSTALL (12) PROPOSED PANEL ANTENNAS (2 513 ANTENNAS AND 2 MICRO ANTENNAS PER SECTOR) • INSTALL (1) PROPOSED ANTENNA FRP SCREEN (ALPHA SECTOR) • INSTALL PROPOSED JUMPERS • INSTALL (12) PROPOSED RRUs (4 PER SECTOR) • INSTALL (3) PROPOSED OVER VOLTAGE PROTECTION DEVICE (OVP) (1 PER SECTOR) • INSTALL (2) PROPOSED POWER CABLES AND (2) PROPOSED FIBER CABLES INSIDE (2) 4"0 PVC CONDUITS (PER SECTOR) ROOFTOP SCOPE OF WORK: • INSTALL (1) PROPOSED WALL MOUNTED EQUIPMENT FRAME • INSTALL (1) PROPOSED BBU IN CABINET DISH Wireless L.L.C. SITE ADDRESS: INSTALL (1) PROPOSED EQUIPMENT CABINET • INSTALL (1) PROPOSED POWER CONDUIT 410 4TH AVE N • INSTALL INSTALL (1) (1) PROPOSED PROPOSED TELCO CONDUIT NEMA 3 TELCO—FIBER BOX • INSTALL (1) PROPOSED GPS UNIT • INSTALL (1) PROPOSED PPC CABINET AND SAFETY SWITCH (IF NECESSARY) EDMONDS, WA 98020 WASHINGTON CODE OF COMPLIANCE ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES CODE TYPE CODE BUILDING 2018 IBC W/ W.A.C. AMENDMENTS MECHANICAL 2018 IMC W/ W.A.C. AMENDMENTS ELECTRICAL 2020 NEC W/ W.A.C. AMENDMENTS SHEET INDEX SHEET NO. SHEET TITLE T-1 TITLE SHEET A-1 OVERALL SITE PLAN A-2 ENLARGED BUILDING PLAN A-3 EQUIPMENT LAYOUT A-4 NORTH AND SOUTH ELEVATIONS A-5 EAST AND WEST ELEVATIONS A-6 EQUIPMENT LAYOUT AND ELEVATION A-7 EQUIPMENT DETAILS A-8 EQUIPMENT DETAILS S-1 EQUIPMENT SUPPORT FRAME DETIALS I S-2 EQUIPMENT SUPPORT FRAME DETIALS II S-3 STRUCTURAL DETAILS S-4 FRP SCREEN MODIFICATION DETAILS S-5 SCREEN SECTION AND ELEVATION E-1 ELECTRICAL/FIBER ROUTE PLAN AND NOTES E-2 ELECTRICAL DETAILS E-3 ELECTRICAL ONE —LINE, FAULT CALCS & PANEL SCHEDULE G-1 GROUNDING PLANS AND NOTES G-2 GROUNDING DETAILS G-3 GROUNDING DETAILS RF-1 RF CABLE COLOR CODE GN-1 LEGEND AND ABBREVIATIONS GN-2 GENERAL NOTES GN-3 GENERAL NOTES GN-4 GENERAL NOTES SITE PHOTO �nnr .� ,..rra ariir r•d aka �r�� �xg UNDERGROUND SERVICE ALERT - WASHINGTON 811 UTILITY NOTIFICATION CENTER OF WASHINGTON (800) 424-5555 WWW.WASHINGTON81 l .COM CALL 2 WORKING DAYS UTILITY NOTIFICATION PRIOR TO CONSTRUCTION GENERAL NOTES THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICIAN WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE. NO SANITARY SEWER SERVICE, POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED. 11 11x17" PLOT WILL BE HALF SCALE UNLESS OTHERWISE NOTED CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS, AND CONDITIONS ON THE JOB SITE, AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. SITE INFORMATION PROJECT DIRECTORY PROPERTY OWNER: EDMONDS PUBLIC APPLICANT: DISH Wireless L.L.C. FACILITIES DISTRICT 5701 SOUTH SANTA FE DRIVE ADDRESS: 410 4TH AVE N LITTLETON, CO 80120 EDMONDS, WA 98020 SITE DESIGNER: CORE ONE CONSULTING USA COUNTY: SNOHOMISH 506 SECOND AVENUE, SUITE 1533 SEATTLE, WA 98104 LATITUDE (NAD 83): 47 48' 51 " N (206) 582-5060 47.81417 N LONGITUDE (NAD 83): 122- 22' 31 " W 122.3753 W SITE ACQUISITION: MIKE SLOTEMAKER ZONING JURISDICTION: CITY OF EDMONDS (206) 214-8954 ZONING DISTRICT: PUBLIC USE CONSTRUCTION MANAGER: MIKE MURPHY (206) 779-6346 PARCEL NUMBER: 27032400207100 RF ENGINEER: MEHMET CAN BALCI OCCUPANCY GROUP: ASSEMBLY GROUP A-3 (562) 552-2122 CONSTRUCTION TYPE: TYPE II POWER COMPANY: SNOPUD TELEPHONE COMPANY: T.B.D. DIRECTIONS DIRECTIONS FROM SEATTLE—TACOMA INTERNATIONAL AIRPORT: HEAD SOUTHEAST ON AIRPORT EXPRESSWAY TOWARD DEPARTURES DR, USE THE LEFT LANE TO KEEP LEFT, SLIGHT LEFT ONTO AIRPORT EXPRESSWAY, KEEP LEFT AT THE FORK, FOLLOW SIGNS FOR WA-518 W/WA-509/BURIEN AND MERGE ONTO WA-518 W. MERGE ONTO WA-518 W. TAKE THE EXIT ONTO WA-509 N TOWARD SEATTLE, WA-509 N TURNS SLIGHTLY LEFT AND BECOMES HWY 99 N/E MARGINAL WAY S. KEEP LEFT TO STAY ON HWY 99 N. TAKE REPUBLICAN ST. EXIT, TURN LEFT ONTO 8TH AVE N. TURN RIGHT ONTO MERCER ST, KEEP LEFT AT THE FORK, MERGE ONTO 1-5 N, TAKE EXIT 177 TO MERGE ONTO WA-104 W/NE 205TH ST/LAKE BALLINGER WAY, CONTINUE ONTO 5TH AVE S, TURN LEFT ONTO PINE ST, TURN RIGHT AT THE 2ND CROSS STREET ONTO 3RD AVE S, TURN RIGHT ONTO 4TH AVE N, DESTINATION WILL BE ON LEFT. VICINITY MAP 7 el a� M� Edmends Center p For th a .Arts a�. SITE LOCATION C524 Daley St Daley St Do ley St Daley St z date's BacldlowTesting N [—NO SCALE • wirel . 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 �01 %oF WASy0 0 10 56058 �<v� O� �FGISTER�� FSSIONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REMSED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS—WA-98020 SHEET TITLE TITLE SHEET SHEET NUMBER T-1 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 I / I � - I I I EXISTING BUILDING EXISTING / I I BUILDING ADJACENT PARCEL: ADJACENT PARCEL: I I I I APN #: 27032400206400 APN #: 27032400224600 I I I / I I ZONING: HR (M) ZONING: T.B.D. I I I - EXISTING TREES (TYP) I L- CAROL WAY \ \ EXISTING PARKING LOT 1 - - - - - - - - \ I I I I PARCEL: _ _ ______ \ \ \ APN : 27032400207100 IO O I I I \\ \ \ ZONING: T.B.D I I I I o I \ \ \ I O EXISTING \ \ \ I o I BUILDING \ \ \ I I Z I I EXISTING \ \ \ I 0 - - W BUILDING \ \ \ 1 I 2 l i l \ \ \\ A-5L A Q I I \ \ \ I of 1 2 1 I I I \ \ I to I -------L---------------� 1\ 1 i I I L-----------L--------- 11 11 I I i GLEN ST - I 1 I I - -- - -- ® I oo I ----� I �I I II �- - - - -� I I I I I I I Z I I I I II Lv II SEE BUILDING PLAN_/ j ADJACENT PARCEL: Q i SHEET A-2) EXISTING I APN #: 1979200185 I I I I BUILDING ZONING: HR (M) I 1 2 I 2 I A-4 � I I BUILDING I I I I I I / EXISTING EXISTING / / / BUILDING O BUILDING I I I � // ------------ - , I L-----------L---------- � - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - L--------------------- DALEY ST - - - - - - - - - - - - - - - - - - - - - / - - - - - - - - - - - 7 , T I OVERALL SITE PLAN NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 2. CONTRACTOR SHALL MAINTAIN A 10'-0" MINIMUM SEPARATION BETWEEN THE PROPOSED GPS UNIT, TRANSMITTING ANTENNAS AND EXISTING GPS UNITS. 32' 24' 16' 8' 0 32' 64' 1 1/32" = i '-0" WhieI/ 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 r% CORE ONE CONSULTING USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 i i Ah- i IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW B 12/20/2021 REVISED PER COMMEMS C 04/04/2022 REVISED PER COMMEMS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE OVERALL SITE PLAN SHEET NUMBER A-1 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 I I I REFER TO ANTENNA LAYOUT ON A-3 lo'leFOR DETAILS G�4�`L.yd ENLARGED ROOF PLAN REFER TO EQUIPMENT LAYOUT ON A-6 FOR DETAILS I I I 0 I 1 I I I I I I I I I10 I I I I EXISTING ROOFTOP EQUIPMENT (TYP) 6 n 1pk�-9 '3a REFER TO ANTENNA LAYOUT ON A-3 FOR DETAILS PROPOSED DISH Wireless L.L.C. 4"0 PVC CONDUIT c/w POWER AND FIBER CABLES ON SLEEPERS (TYP 2 PER SECTOR, TOTAL 6) EXISTING BUILDING ROOFTOP NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 2. CONTRACTOR SHALL MAINTAIN A 10'-0" MINIMUM SEPARATION BETWEEN THE PROPOSED GPS UNIT, TRANSMITTING ANTENNAS AND EXISTING GPS UNITS. 3. CONTRACTOR TO VERIFY WITH DISH Wireless L.L.C. C.M. THE LOCATION OF THE POWER AND FIBER SOURCE PRIOR TO CONSTRICTION. 4. UTILITY RUBBER MAT TO BE IN STALLED UNDER ALL DISH Wireless L.L.C. EQUIPMENT THAT IS RESTING ON OR AFFIXED TO ROOF MEMBRANE 5. ALL PANEL ANTENNAS, RRH'S AND MOUNTING HARDWARE TO BE PAINTED TO MATCH EXISTING BUILDING. 6' 4' 2' 0 5' 10' wNMI 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 `� CORE ONE 1 CONSULTING USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B.� i %oF AS 'o p � ®� �FOWER�� FSSIONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE ENLARGED ROOF PLAN SHEET NUMBER A-2 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 3/16"=1'-0' NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. oI � 00 o N PROPOSED DISH WIRELES: L.L.C. OVP DEVICE (TYP 1 PER SECTOR, TOTAL 3). REFER TO A-8 FOR DETA PROPOSED DISH Wireless L.L.C. RRU's MOUNTED TO WALL. REFER TO A-8 FOR DETAILS PROPOSED DISH Wireless L.L.C. ANTENNA WALL MOUNT, TYP. REFER TO A-8 FOR DETAILS 0 Cl 0 O PROPOSED DISH Wireless L.L.C. ANTENNAS (TYP 2 513 ANTENNAS AND 2 MICRO ANTENNAS PER SECTOR, TOTAL 12). REFER TO S-5 DETAIL 4 FOR ANTENNA MOUNT DETAILS 0 O t10$-10" Iva C2 f 10$-lose A5 4K PROPOSED DISH Wireless L.L.C. ANTENNAS (TYP 2 5G ANTENNAS AND 2 MICRO ANTENNAS PER SECTOR, TOTAL 12). O o o REFER TO S-5 DETAIL 4 FOR ANTENNA Al O MOUNT DETAILS MODIFY EXISTING ANTENNA SCREEN TO ALLOW FOR PROPOSED DISH Wireless 0 L.L.C. ANTENNA FRP SCREEN. REFER 0 TO S-4 FOR DETAILS 0 PROPOSED DISH Wireless L.L.C. ANTENNA WALL MOUNT, TYP. REFER TO A-8 FOR DETAILS PROPOSED DISH Wireless L.L.C. 4*0 PVC CONDUIT c/w POWER AND FIBER CABLES ON SLEEPERS (TYP 2 PER SECTOR, TOTAL 6). REFER A-8 FOR DETAILS PROPOSED DISH WIRELESS L.L.C. OVP DEVICE (TYP 1 PER SECTOR, TOTAL 3). REFER TO A-8 FOR DETAILS O 00 O 0 C3 C4 I N O 0 00 ANTENNA PLAN (ALPHA & GAMMA SECTOR) MODIFY EXISTING ANTENNA SCREEN TO ALLOW FOR PROPOSED DISH Wireless L.L.C. ANTENNA FRP SCREEN. REFER TO S-4 FOR DETAILS 12" 6" 0 1 ' 2' 3' 4' 5' 6' 7' 3/8"=1 '-0" SECTOR POSITION RRH NOTES 1. CONTRACTOR TO REFER TO FINAL CONSTRUCTION REDS FOR ALL RF DETAILS. 2. ANTENNA AND RRH MODELS MAY CHANGE DUE TO EQUIPMENT AVAILABILITY. ALL EQUIPMENT CHANGES MUST BE APPROVED AND REMAIN IN COMPLIANCE WITH THE PROPOSED DESIGN AND STRUCTURAL ANALYSES. MANUFACTURER - MODEL NUMBER TECHNOLOGY ALPHA Al TA08025-B604 n70/n66 Al TA08025-B605 n70/n66 A2 TA08025-B604 n70/n66 A2 TA08025-B605 n70/n66 BETA B1 TA08025-B604 n70/n66 B1 TA08025-B605 n70/n66 B2 TA08025-B604 n70/n66 B2 TA08025-13605 n70/n66 GAMMA G1 TA08025-B604 n70/n66 G1 TA08025-B605 n70/n66 G2 TA08025-B604 n70/n66 G2 TA08025-B605 n70/n66 RRU SCHEDULE 3 PROPOSED DISH Wireless L.L.C. 4"0 PVC CONDUIT c/w POWER AND FIBER CABLES ON SLEEPERS (TYP 2 PER SECTOR, TOTAL 6). REFER A-8 FOR DETAILS PROPOSED DISH WIRELESS L.L.C. OVP DEVICE (TYP 1 PER SECTOR, TOTAL 3). REFER TO A-8 FOR DETAILS ANTENNA PLAN (BETA SECTOR) B4 B3 B2 PROPOSED DISH Wireless L.L.C. ANTENNAS (TYP 2 5G ANTENNAS AND 2 MICRO ANTENNAS PER SECTOR, TOTAL 12). REFER TO A-8 FOR DETAILS PROPOSED DISH Wireless L.L.C. RRU's MOUNTED TO WALL. REFER TO A-8 FOR DETAILS UTILIZE EXISTING ANTENNA WALL MOUNTS FOR PROPSOED DISH Wireless L.L.C. ANTENNAS. REFER TO S-3 FOR DETAILS Oro 6 n FCjO.9 a B1 PROPOSED DISH Wireless L.L.C. RRU's MOUNTED TO WALL. REFER TO A-8 FOR DETAILS 4' 2' 0 4' 8' 1 /4"=1 '-0" SECTOR POSITION ANTENNA TRANSMISSION CABLE EXISTING OR PROPOSED MANUFACTURER - MODEL NUMBER TECHNOLOGY SIZE (HxW) AZIMUTH RAD CENTER FEED LINE TYPE AND LENGTH ALPHA Al PROPOSED MX08FR0665-21 VOF 5G 72.0" x 20.0" 30' 48'-8" (2) POWER CABLES (2) FIBER CABLES (30' LONG t) A2 PROPOSED MX08FR0665-21 VOF 5G 72.0" x 20.0" 30' 48'-8" A3 PROPOSED CCI-HPA45F-TE2AA MICRO 25.9" x 15.9se 30' 48'-8" A4 PROPOSED CCI-HPA45F-TE2AA MICRO 25.9" x 15.9" 30' 48'-8" BETA B1 PROPOSED MX08FR0665-21 VOF 5G 72.0" x 20.0" 130' 48'-8" (2) POWER CABLES (2) FIBER CABLES (50' LONG f) B2 PROPOSED MX08FR0665-21 VOF 5G 72.0" x 20.0" 130' 48'-8" B3 PROPOSED CCI-HPA45F-TE2AA MICRO 25.9" x 15.9se 130' 48'-8" B4 PROPOSED CCI-HPA45F-TE2AA MICRO 25.9" x 15.9se 130' 48'-8" GAMMA Cl PROPOSED MX08FR0665-21 VOF 5G 72.0" x 20.0" 230' 48'-8" (2) POWER CABLES (2) FIBER CABLES (105' LONG t) C2 PROPOSED MX08FR0665-21 VOF 5G 72.0" x 20.0" 230' 48'-8" C3 PROPOSED CCI-HPA45F-TE2AA MICRO 25.9" x 15.9m 230' 48'-8" C4 PROPOSED CCI-HPA45F-TE2AA I MICRO 25.9" x 15.9se 230' 1 48'-8" ANTENNA SCHEDULE I,r m*0_12><:11 2 E wirel 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B. 4 1 j'pE WAS '0 0 56058 `vim O� �F0 ST E FSSIONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE ANTENNA PLAN, ELEVATION AND SCHEDULE SHEET NUMBER A-3 DISH Wireless L.L.C. TEMPLATE VERSION 40 - 08/13/2021 MODIFY EXISTING ANTENNA SCREEN TO ALLOW FOR PROPOSED DISH Wireless L.L.C. ANTENNA FRP SCREEN PROPOSED DISH WIRELESS, LLC. ANTENNA (TYP 2 5G ANTENNAS AND 2 MICRO ANTENNAS PER SECTOR, TOTAL 12). REFER TO A-8 FOR DETAILS PROPOSED DISH Wireless L.L.C. RRU's MOUNTED TO WALL. REFER TO A-8 FOR DETAILS PROPOSED DISH Wireless L.L.C. EQUIPMENT CABINET MOUNTED TO PENTHOUSE WALL. REFER TO S-1 AND S-2 FOR DETAILS EXISTING PENTHOUSE ROOF TOP ELEV. @ ±51'-10" AGL PROPOSED DISH WIRELESS ANTENNA RAD CENTER O f48'-8" AGL PENTHOUSE ROOF TOP ELEV. O t51'-1 RAD CENTER O NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 2. CONTRACTOR SHALL MAINTAIN A 10'-0* MINIMUM SEPARATION BETWEEN THE PROPOSED GPS UNIT, TRANSMITTING ANTENNAS AND EXISTING GPS UNITS. 3. ALL PROPOSED DISH Wireless L.L.C. EQUIPMENT, PANEL ANTENNAS AND FRP SCREENING WILL BE PAINTED TO MATCH EXISTING BUILDING. EXISTING BUILDING PARAPET 37'-4" AGL EXISTING BUILDING ROOF 36'-4" AGL GRADE 0' - 0' 12' 8' 4' 0 10' 20' BUILDING NORTH ELEVATION NOTES EXISTING EQUIPMENT PROPOSED DISH WIRELESS, LLC. ANTENNA (TYP 2 5G ANTENNAS AND 2 MICRO ANTENNAS PER SECTOR, TOTAL 12). REFER TO A-8 FOR DETAILS BUILDING SOUTH ELEVATION 0 PROPOSED DISH Wireless L.L.C. EQUIPMENT CABINET MOUNTED TO PENTHOUSE WALL. REFER TO S-1 AND S-2 FOR DETAILS I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I F1 11IF1JAI II I I IF1 1111IIJ F] 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 2. CONTRACTOR SHALL MAINTAIN A 10'-0" MINIMUM SEPARATION BETWEEN THE PROPOSED GPS UNIT, TRANSMITTING ANTENNAS AND EXISTING GPS UNITS. 3. ALL PROPOSED DISH Wireless L.L.C. EQUIPMENT, PANEL ANTENNAS AND FRP SCREENING WILL BE PAINTED TO MATCH EXISTING BUILDING. EXISTING BUILDING PARAPET 37'-4" AGL EXISTING BUILDING ROOF 36'-4" AGL GRADE 0' - 0' 12' 8' 4' 0 10' 20'ii I 2 wirel . 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B. 4 1 j'pE WAS 'o 0 56058 `vim O� �FGISTE FSS/O NAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE NORTH AND SOUTH ELEVATIONS SHEET NUMBER A-4 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 3/32"=1 '-0' PROPOSED DISH WIRELESS, LLC. ANTENNA (TYP 2 513 ANTENNAS AND 2 MICRO ANTENNAS PER SECTOR, TOTAL 12). REFER TO A-8 FOR DETAILS EXISTING PENTHOUSE ROOF TOP ELEV. @ f51'-10" AGL PROPOSED DISH WIRELESS ANTENNA RAD CENTER O t48'-8' AGL PROPOSED DISH Wireless L.L.C. RRU's MOUNTED TO WALL. REFER TO A-8 FOR DETAILS EXISTING EQUIPMENT EXISTING WALL MOUNTED EQUIPMENT I j I I J I IIF I I I L- L L I-- L I - BUILDING EAST ELEVATION BUILDING WEST ELEVATION PROPOSED DISH WIRELESS, LLC. ANTENNA (TYP 2 5G ANTENNAS AND 2 MICRO PROPOSED DISH Wireless L.L.C. UTILITY H—FRAME PROPOSED DISH Wireless L.L.C. VERTICAL CABLE TRAY FOR POWER AND FIBER CABLE ROUTING UP TO PENTHOUSE PROPOSED DISH Wireless L.L.C. EQUIPMENT CABINET MOUNTED TO PENTHOUSE WALL. REFER TO S-1 AND S-2 FOR DETAILS NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 2. CONTRACTOR SHALL MAINTAIN A 10'-0* MINIMUM SEPARATION BETWEEN THE PROPOSED GPS UNIT, TRANSMITTING ANTENNAS AND EXISTING GPS UNITS. 3. ALL PROPOSED DISH Wireless L.L.C. EQUIPMENT, PANEL ANTENNAS AND FRP SCREENING WILL BE PAINTED TO MATCH EXISTING BUILDING. EXISTING BUILDING PARAPET 37'-4" AGL EXISTING BUILDING ROOF 36'-4" AGL GRADE 0'-0' 12' 8' 4' 0 10' 3 /32"=1 '-0" NOTES 20' 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 2. CONTRACTOR SHALL MAINTAIN A 10'-0" MINIMUM SEPARATION BETWEEN THE PROPOSED GPS UNIT, TRANSMITTING ANTENNAS AND EXISTING GPS UNITS. iUPUSLU UISH Wireless LLU. EQUIPMENT, ANTENNAS AND FRP SCREENING WILL BE D TO MATCH EXISTING BUILDING. 'ING BUILDING PARAPET 37'-4" AGL LISTING BUILDING ROOFAdk 36'-4" AGL 12' 8' 4' 0 GRADE 0' — 0' 10' 20'ii I 2 wirel . 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B. 4 1 j'pE WAS 'o 0 56058 `vim O� �FGISTE FSSIONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE EAST AND WEST ELEVATIONS SHEET NUMBER A-5 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 3/32"=1 '-0" PE EXISTING MAIN ROOF 2 EXISTING PENTHOUSE toROOF ACCESS LADDER I � I PROPOSED DISH Wireless L.L.C. POWER AND FIBER CABLES ROUTED TO THIS SIDE OF CABINET I • PROPOSED DISH WIRELESS, LLC. EQUIPMENT CABINET MOUNTED TO PENTHOUSE WALL. REFER TO A-7 FOR EQUIPMENT DETAILS AND S-1 AND S-2 FOR FRAME DETAILS N vs I s N wl -n I1 II II II II EXISTINGNTHOUSU ROOF ROOF I II II II I I PROPOSED DISH WIRELESS, LLC. FIBER NID, IF REQUIRED. REFER TO A-7 FOR DETAILS PROPOSED DISH Wireless L.L.C. POWER PROTECTIVE CABINET PROPOSED DISH Wireless L.L.C. 4"0 PVC CONDUIT c/w POWER AND FIBER CABLES ON SLEEPERS (TYP 2 PER SECTOR, TOTAL 6). REFER TO A-8 FOR DETAILS EQUIPMENT LAYOUT NO SCALE I 1 PROPOSED DISH Wireless L.L.C. VERTICAL CABLE TRAY FOR POWER AND FIBER CABLE ROUTING UP TO PENTHOUSE PROPOSED DISH Wireless L.L.C. POWER PROTECTIVE CABINET. REFER TO A-7 FOR DETAILS PROPOSED DISH Wireless L.L.C. 200AMP CHECK METER. REFER TO A-7 FOR DETAILS Cs711 100000001 000000000 0000000 PROPOSED DISH WIRELESS, LLC. FIBER NID, IF REQUIRED. REFER TO A-7 FOR DETAILS PROPOSED DISH Wireless L.L.C. TELCO FIBER ENCLOSURE. REFER TO A-8 FOR DETAILS D R �7 n • EQUIPMENT ELEVATION NOTE 1. EQUIPMENT CABINET OMITTED FOR CLARITY PROPOSED DISH WIRELESS, LLC. WOOD PLATFORM. TYP. OF 2. REFER TO S-2 FOR DETAILS PROPOSED DISH WIRELESS, LLC. EQUIPMENT CABINET MOUNTED TO PENTHOUSE WALL. REFER TO A-7 FOR EQUIPMENT DETAILS AND S-1 AND S-2 FOR FRAME DETAILS L_ NO SCALE I 2 (i S ` irel 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 r CORE ONE CONSULTING USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 t01 B. 4 i %oF WAS 'o � p Z 56058 �<v� O� tGISTER�� FSS�ONALE�� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE EQUIPMENT LAYOUT AND ELEVATION SHEET NUMBER A-6 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 CHARLES INDUSTRY HEX CHARLES INDUSTRY 00 ° °40 E—MON D—MON SMART METER CUBE—PM639155N4 LT-97-002422 PLINTH KIT CLASS 3200 • DIMENSIONS (HxWxD): 74"x32"02" DIMENSIONS (HxWxD) 6"02"02" DIMENSIONS (HxWxD) 6"x6"x4.5" POWER PLANT: —48VDC ABB/60OW \ NOTE: GASKET AND MOUNTING HARDWARE INCLUDED WEIGHT N/A TOTAL WEIGHT (EMPTY) 408 LBS Elm v"l�. ME O 0 0 0 5701 SOUTH SANTA FE DRIVE I op ° ° LITTLETON, CO 80120 O a a O PLAN ° ° p 00 00 00 00 00 00 0 0 • CORE ONE 0 0 O O CONSULTING USA Q Q FRONT/� �1QEAl Q = _ = Q 13555 SE 36TH ST, SUITE 100 FRONT BELLEVUE, WA 98006 FRONT CABINET DETAIL No SCALE PLINTH KIT DETAIL No SCALE 2 METER BANK DETAIL No SCALE 3 ZAYO 5RU (LEFT SWING DOOR) CHARLES CFIT—PF202ODSH 1 RAYCAP PPC FIBER NID ENCLOSURE @ OO FIBER TELCO ENCLOSURE RDIAC-2465—P-240—MTS DIMENSIONS (HxWxD) 36.1 "x29"x12.9" QO 0 ENCLOSURE DIMS (HxWxD) 20"x20"x9" ENCLOSURE DIMENSIONS (HxWxD): 39"x22.855"02.593 #' \_ B. 441 F WEIGHT 85 Ibs 0 0 0 WEIGHT: 80 Ibs ^ As� �4 of WA ENCLOSURE WEIGHT 20 Ibs e BOTTOM MOUNTING WALL OPERATING AC VOLTAGE 240/120 1 PHASE 3W+G e ® ® ® ®®® ®®®®®® COMPLIANCE TYPE 4 56058 FS�FCISTER� S�ONA1� o FRONT El °°° 0 0 O O 0 0 ° ° ° ® 0 O IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. ® ® ® DRAWN BY: CHECKED BY: APPROVED BY: AF LC ML 0 0 ®®® ® O O RFDS REV #: --- QQ 0 0 0 0 O O 0 0 O 0 0 1 0 0 0 10° 0 CONSTRUCTION EWA am mow f&K mow BACK FRONT DOCUMENTS FIBER NID ENCLOSURE DETAIL No SCALE 4 FIBER TELCO ENCLOSURE DETAIL No SCALE 5 POWER PROTECTION CABINET (PPQ DETAIL No SCALE 6 SUBMITTALS REV DATE DESCRIPTION P C T E L A t 2/t 0/2021 ISSUED FOR REVIEW G P S G L— T M G— S P I— 40 N C B 1.75"0 1 '60"� 8 12/20/2021 REVISED PER PER COwIMEM'S MINIMUM OF 75X OR C 04/04/2022 REVISED PER COMMEM 0 04/20/2022 ISSUED FOR CONSTRUCTION 270' IN ANY DIRECTION 110, DIMENSIONS (DIAxH) MM/INCH 81 x184mm 0 3.2"x7.25" GPS WEIGHT W/ACCESSORIES 075 Ibs CONNECTOR N—FEMALE A&E PROJECT NUMBER FREQUENCY RANGE 1590 f 30MHz 6�N,y�N Bg+� �ivs �'Qgp�G SESEA00426D s CUI2PSM6P4XXX CUI2PSM9P6XXX DISH Wireless L.L.C. PROJECT INFORMATION (4 AWG CONDUCTORS) (6 AWG CONDUCTORS) GPS UNIT BESTRu WON MUST SESEA00426D 1.4100 410 4TH AVE N EDMONDS_WA_98020 o o � 0 0 SHEET TITLE O O U eFNo2;M� EQUIPMENT DETAILS s CUI2PSM9P8XXX SHEET NUMBER K �1QE (8 AWG CONDUCTORS) A-7 GPS MINIMUM SKY VIEW REQUIREMENTS No SCALE 7 GPS DETAIL No SCALE 8 CABLES UNLIMITED HYBRID CABLE No SCALE 9 MINIMUM BEND RADIUSES DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 FUJITSU DUAL BAND FUJITSU TRIPLE BAND COMMSCOPE MOUINT WILL FIT LEGS UP T0: TA08025-13604 TA08025-13605 RR-FA2 EXT - 5.6" ROUND • - 6.0" 60' ANGLE JMA CCI RAYCAP RDIDC-9181-PF-48 MX08FRO665-21 HPA45F-TE2AA DC SURGE PROTECTION DIMENSIONS (HxWxD) 72"x20.0"x8.0" RF PORTS, CONNECTOR TYPE 8 x 4.3-10 FEMALE PLC DIMENSIONS (HxWxD) 25.9"x15.9"x8.1" RF PORTS, CONNECTOR TYPE 6 x 4.3-10 FEMALE DIMENSIONS (HxWxD) WEIGHT 18.98"x14.39"x8.15" 21.82 LBS B. �FF� of `ASy����F� e e WEIGHT WEIGHT WITH BRACKETS 64.5 The 82.5 Ibs WEIGHT WEIGHT WITH BRACKETS 18.3 Ibs 28.1 Ibs PLAN PLC 56058 O� �FGISTE \� FSSIONAL 0 0 110 Q IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: co AF LC M L 10 � o RFDS REV #: --- �lQE FRONT IL ' CONSTRUCTION mow am mow DOCUMENTS ANTENNA DETAIL NO SCALE 4 ANTENNA DETAIL NO SCALE 5 SURGE SUPPRESSION DETAIL NO SCALE 6 SUBMITTALS REV DATE DESCRIPTION DURA-BLOK DB20 ROOFTOP CABLE SUPPORT 5" DIMENSIONS (HxWxL) 5"x6"x20.2" MOUNTING MOUNTING CLAMPING BOLT MOUNTED IN PLATE OF RRH (TYP) NUT WITH REGULAR A 12/10/2021 MUM FM REMEW 8 12/20/2021 REVISED PM PER coMMEMs C 04/04/2022 REVISED PER COMMEMS o 04/20/2022 IssuED FOR coNsrRucnoN WEIGHT/ VOLUME 10.63 LBS SPRING OR APPROVED EQUAL (TYP) ULTIMATE LOAD CAPACITY 1000 LBS A&E PROJECT NUMBER NOTE: NON —PENETRATING EXISTING WALL SESEA00426D EPDXY CAPSULE DISH Wireless L.L.C. PIPE CLAMP OR APPROVED LLEQUAL IN CABLE OO N = STEEL CHANNEL—,.._---------- ---------- --------------------- ---------------------- -- - - ------ - ---------- BOLT 3 EXPANSION ANCHOR OR APPROVED EQUAL PROJECT INFORMATION SESEA00426D 410 4TH AVE N RUBBER EDMONDS_WA_98020 SUPPORT UNISTRUT ON - - - - co EXISTING WALL MOUNTING PLATE SHEET TITLE EQUIPMENT DETAILS RRU/OVP SHEET NUMBER PLC FRONTS EQUIPMENT A-8 ROOFTOP CABLE SUPPORT DETAIL NO SCALE 7 RRH f OVP UNISTRUT WALL MOUNT DETAIL NO SCALE 8 NOT USED NO SCALE 9 DISH Wireless L.L.C. TEMPLATE VERSION 40 - 08/13/2021 EXISTING CONCRETE WALL PROPOSED DISH WIRLESS, PL 6mm LLC. EQUIPMENT CABINET. END CAP REFER TO A-7 FOR DETAILS S-2 ❑ ❑ 1'-2" MAX WEIGHT =14001bs _ 0 0 1* =x N N 0 0o S-2 o a a 1 /4" END CAP--,, 10 Fh I I 4'-0" WOOD PLATFORM NOT SHOWN FOR CLARITY. REFER TO S-2 FOR DETAILS EQUIPMENT FRAME SECTION 8" REFER TO NOTE 1 6 I m CAULK AROUND TOP AND SIDES, TYP. 3/4" DIA. THREADED ROD (ASTM Gr B7 RODS). FASTEN WITH HILTI HIT—HY 200 ADHESIVE SYSTEM, EMBED 4", TYP. 12" 9" 6" 3" 0 1 21 1 NOTES 1. CONTRACTOR TO SITE VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 2. PROVIDE VENT HOLES AS REQUIRED FOR GALVANIZING. 3. ALL WELDS TO BE SEALED. 4. ANCHOR EQUIPMENT CABINET AS PER MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR TO VERIFY EXACT EQUIPMENT MODEL USED AND VERIFY ANCHOR HOLE LOCATIONS PRIOR TO FABRICATION 2'-3" co go G _.� C .� .Q d a d yyJJII . a d �� a _�.�'vQ� _ 0 _ 0 i ------------ i� EQUIPMENT FRAME PLAN L 4"x4"x 1 /4" EXISTING CONCRETE WALL OUTLINE OF PROPOSED DISH WIRLESS, LLC. EQUIPMENT CABINET. REFER TO A-7 FOR DETAILS REFER TO DETAIL 7 ON S-2 FOR CABINET MOUNTING DETAILS ANCHOR HOLE TO SUIT, TYP. 12" 9" 6" 3" 0 1' 2 wirel . 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B.� 1 j'oE WAS 'o 0 56058 `vim O� �FGISTE FSS�ONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE EQUIPMENT FRAME DETAILS I SHEET NUMBER S.1 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 »=1'- • a 1 1/2" 9" PL 1/4" END CAP 3/4" DIA. THREADED ROD (ASTM Gr B7 RODS). FASTEN WITH HILTI HIT—HY 200 ADHESIVE SYSTEM, EMBED 50 9 TYP. PL 5/8"x8x1'-0" 6V v... HSS 4"x102x6mm PLATE CONNECTION DETAIL • N 1 /2" DIA. A325 B01 TYP. PL 1 /4"x ... . CONNECTION DETAIL 4" HSS 4"x4"0/8" 1 /2" DIA. A325 BOLTS, TYP. k4"x1 /4" 4" CONNECTION PLATE NO SCALE CONNECTION DETAIL HSS 4"x4"x3/8" L 4"x4"x 1 /4" 1 /4" V TYP. HSS 4"x4"x3/8" 9" 11 1 /2" + 1 L A 3/4" DIA. THREADED ROD (ASTM Gr B7 RODS). FASTEN WITH HILTI HIT—HY 200 ADHESIVE SYSTEM, co EMBED 50, TYP. PL 5/8"x8x1'-0" N 1 /4" HSS 4"x4"x3/8" 1 /4" PF DISH WIRELESS, LLC. UIPMENT CABINET UIPMENT CABINET TO BE CHORED WITH A THRU—BOLT DRILL AND TAP S 4"x4"0/8" 1/4"x3"x3" WASHER CABINET MOUNTING DETAIL NO SCALE 1 4 NO SCALE 1 7 11 m I M CONNECTION DETAIL 3'-3" „ RUBBER MAT BELOW 3'-0" WOOD PLATFORM LAYOUT NO SCALE 1 2 NO SCALE 1 5 1 "#14R RAISED GALVANIZED METAL EXPANDED MESH. FASTEN TO PLATFORM WITH 38mm GALVANIZED U—NAILS AT 203mm 0/C EACH WAY 2x6, TYP. 200 PERIMETER, TYP. #9 DECKING SCREW x64mm LG. , TYP. NO SCALE 1 8 L 3"x3"x1/4" 1 /2" DIA. A3,' BOLTS, TYP. L 4"x4"x 1 /4" HSS 4"x4"x3/8" TYP.>--K--�' HSS 4"x4"x3/8" CONNECTION DETAIL S-2 3/8" 3/8" PL 3/8"4"4 1 /2" —,'-' #9 DECKING SCREW x64mm LG. , TYP. T.O. EXISTING ROOF HSS 4"x4"x3/8" PL 1/4- CONNECTION PLATE 1 /4" END PLATE NO SCALE I 3 a, ° PL 5/8"x8"x1'-0" a a . a 3/4" DIA. THREADED ROD (ASTM Gr B7 RODS). FASTEN WITH HILTI HIT—HY 200 ADHESIVE a SYSTEM, EMBED 5", TYP. d d C C J• a a N as a J• ° a CONNECTION DETAIL WOOD PLATFORM SECTION NO SCALE 1 6 24, TYP. 200 PERIMETER, TYP. 1" RUBBER MAT NO SCALE 1 9 • VwmaI' s 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 �0LB.� of W A Sy�FA 0 56058 `vim O� �FGISTER�� FSS10NAL��� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE EQUIPMENT FRAME DETAILS II SHEET NUMBER S-2 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 2-7/8"0 STD. PIPE x 6'-0" LG. r I F,,I I III Ir 1 1 = PROPOSED ANTENNA 0 ulll I 1 INSTALLED BY I CONTRACTOR, TYP. ; A _� .� o II 10 11 I I I I I I I I I I I I I I I INSTALL 1 /2"0 U—BOLT I I I I I I I I I I TO SUIT EXISTING I I HOLES, TYP. OF 2 I I I I I I I I I II I—L —A I I I I I I I I EXISTING WALL MOUNT MODIFICATION DETAILS 0 iq EXISTING CONCRETE PENTHOUSE WALL 12" 9" 6" 3" 0 v a. dd' ° 6" ° 4 . d ° a p. d"° a. a ° o dd d°. d o v" a a a d 4 a d d :d° _ .d Q d d_ ._d 0 4 4 ;a .d° .° ad v ' ° v d 1 /2" DIA. THREADED a d° a 4. ROD c/w HILTI HIT—HY ° a. 200 ADHESIVE SYSTEM, a . ° EMBED 3", TYP. v d d a a. ° o a d d d d C ° .d ° O ° d d .4 . a v, a 4 dd d ° d d. c a ° a 4—d ° ° v. 4 a ° 4. a d a d a. d '. a PROPOSED DISH Wireless a °° d a a ° L.L.C. DC SURGE a a ° ' °. a . a PROTECTION BOX (OVP) °. ° .a . ° a °. ° . ° °. a. d d a d d v° d d d a. .d ° ..v ._ . CONTRACTOR TO USE °° ° d PROPOSED DISH ° a ° a �I 4 w a ' CABLE WALL MOUNT a Wireless L.L.C. RRU's 49d N SUPPORTS AS NECESSARY a d (TYP. OF 2). REFER ° a' a ° a d °. a TO A-8 FOR DETAILS ° ° a .. . d a a d v d 'a .. ° d a a d d° d_ G a d. d. A Q' .a a °. _ _ d a. a d ° d d d .v a a .d d d_ v. d ° d a _ _ a d. Q ° ° v: 4-4 a. da a a d d dd ° . d ad v .4 a Q' _ ° ° d a ° a v ° .4 d d" a Q ° a d .Q d ..�d.. a� ° _.a' ° EXISTING ° a CONCRETE ° a WALL °� °d ° ' a a a 4. d ° v a d G ° d' :a Q.. '. da° a a v ' d c a d d. °. d 4. . ° d.°' ° v. d Q a d n 4, °'' a d a 44 a .° d a d' d Q d 41 . d .. RRH MOUNTING ELEVATION a. d. a. a d a 1290 99' 699 39' 0 1' 2 • whiel 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 r CORE ONE CONSULTING USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 41 � � M IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW B 12/20/2021 REVISED PER COMMEMS C 04/04/2022 REVISED PER COMMEMS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE STRUCTURAL DETAILS SHEET NUMBER S-3 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 1 1 /2"=1 '-0» vs I N L 4"x4"x3/8" (AT BACK OF SCREEN CONNECTED TO WALL), TYP. PROPOSED T—MOBILE LEASE SPACE, TYP (SCREEN DESIGNED BY OTHERS). 2" 3'-6" 1'-2" 1'-2" TYP. 4 S-5 10$-10" 3'-6" 1'-2" 1'-2" 1'-9" FRP L 4"x4"x3/8" VERTICALS. FASTEN WITH FRP L 4"x4"0/8" CUP ANGLES TOP AND BOTTOM 1'-9" 3'-6" 1'-2" 3/8" FRP CORNER PLATE, TYP. AT ALL 4 CORNERS TOP AND BOTTOM 1'-90 J 00 1'-9" TIE EXISTING SCREEN TO ANGLE, TYP. WITH 3/8" FRP BOLT AT 12" O.C. `5/8" DIA. FRP BOLTS, TYP. MP L 4"x4"x3/8", TYP. 2 S-5 O 0 CONCRETE FILLED BLOCKS: USE 5/8" DIA. THREADED ROD C/W HILTI HIT—HY 200 ADHESIVE SYSTEM EMBED 5" HOLLOW BLOCKS: USE 5" DIA. THREADED ROC C/W HILTI HIT—HY 70 EMBED 5" PROPOSED T—MOBILE LEASE SPACE, TYP (SCREEN DESIGNED BY OTHERS). 12" 9» 6" 3» 0 it 2, ALPHA SECTOR FRP SCREEN PLAN 1 "=1'-0" GAMMA SECTOR FRP SCREEN PLAN TTniiiiiiiiiiii 1200 9" 6" 3" 0 it 2' 1 "=1'-0" 2 • awireI' s 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B.� 1 j' of WA Sy�FA 0 56058 `vim O� �FGISTE FSS�ONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE FRP SCREEN MODIFICATION DETAILS SHEET NUMBER S-4 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 no n" FRP CORNER PLATE, AT ALL 4 CORNERS AND BOTTOM L 4"x4"x3/809 TYP. L 3"x3"1 /4" )NAL BRACE, TYP. ;RETE FILLED BLOCKS: 5/8" DIA. THREADED C/W HILTI HIT—HY 200 :SIVE SYSTEM EMBED OW BLOCKS: 5" DIA. THREADED ROC HILTI HIT—HY 70 :D 5" c4"x3/8" (AT BACK ;CREEN CONNECTED 11ALL), TYP. M 12" 9" 6" 3" 0 1 ' SECTION FRP L 4"x4"x3/8" TO CONNECT EXISTING SCREEN 10" SECTION 4" 6" 3" 2" 12" �_ . ." ." _ ._" -FRP L 4"x4"x3/8", TYP. 3/8" FRP CORNER PLATE, TYP. AT ALL 4 CORNERS TOP AND BOTTOM 5/8" DIA. FRP BOLTS, TYP. 91 ELEVATION 3 12" 99p 6" 39p 0 SABRE WALL MOUNT C 10201001 DIMENSIONS (HxWxD) (PER BRACKET) 10"x13.5"x8" WEIGHT (2 BRACKETS W/O PIPE) 54 Ibs NOTE: OR DISH Wireless L.L.C. APPROVED EQUIVALENT ANTENNA WALL MOUNT DETAIL 1 1 /2"=1 ' —0" ISOMETRI VIEW 2 m • awireI' s 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 �0 L B. 4 of W A Sy�FA 0 56058 `vim O� �FGISTE F'sSIONAL��� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE SCREEN SECTION AND ELEVATION SHEET NUMBER S-5 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 Nm PARTIAL BALCONY LEVEL FLOOR PLAN CONTRACTOR TO COORDINATE WITH LANDLORD FOR EXACT FIBER i TERMINATION LOCATION i ❑ TELECOMM ROOM EXISTING HVAC r-- UNIT, TYP. i m u- w m u- FBR ELECTRICAL Rnnnn EXISTING ANSFORMER, TYP. FBR FBR ELECTRICAL ROOM LAYOUT (BALCONY LEVEL NOTE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. RACEWAYS ROUTED DOWN TO ELECTRICAL ROOM ON BALCONY LEVEL. REFER TO DETAIL 2 FOR CONTINUATION OSED FIBER CONDUIT (LENGTH: 90'-00:0 3—#3/0 THHN PLUS #6 GROUND IN 2" EMT CONDUIT CONTRACTOR TO SITE VERIFY AND COORDINATE WITH LANDLORD FOR EXACT ROUTING OF RACEWAYS PROPOSED DISH WIRELESS, LLC. FIBER NID, IF REQUIRED PROPOSED DISH Wireless L.L.C. 200A, 120/208V, 1 PH, 3W CHECK METER PROPOSED POWER PROTECTIVE CABINET 120/24OV, 1 PH, SERVICE RATED, OVERALL UL LISTED POWER CENTER, N3R, 65K/10K AIC 6' 4' 2' 0 5' 1 0' 1 3/16"=1'—Opt ----------- NOTE - CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. lip EXISTING 2000A, 480/277V, 3PH, 4W SWITCHBOARD I EXISTING ELECTRICAL PANEL, TYP. i lip EXISTING MAIN GROUND i BELOW PANEL i i i PROPOSED MAIN GROUND I� CONDUIT RUN (LENGTH: 85-0"t) PROPOSED FIBER CONDUIT RUN (LENGTH: 90'-0"t) Ii 3—#3/0 THHN PLUS #6 GROUND IN 2 EMT CONDUIT RACEWAYS ROUTED UP TO ROOF LEVEL REFER TO DETAIL 1 FOR CONTINUATION - FBR FBR i VESTIBULE EXISTING PANEL "N2BL1" 1200A, 120/208V, 3PH, 4W. INSTALL 200A, 208V. 2P CIRCUIT BREAKER TO MATCH EXISTING 4' 2' 0 4' 8' 1 4"=1 '-0" vwm al . 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B.� 1 j'pE WASI � 10 0 56058 `vim O� �FGISTE FSSIONAL��� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE ELECTRICAL/FIBER ROUTE PLAN AND NOTES SHEET NUMBER E-1 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 DC POWER WIRING SHALL BE COLOR CODED AT EACH END FOR IDENTIFYING +24V AND —48V CONDUCTORS. MARKINGS SHALL IDENTIFY +24V AND BLUE MARKINGS SHALL IDENTIFY —48V. DISH Wireless L.L.C. PROVIDES 12AWG 0 0 WIRE (6' TAIL) NN DISH Wireless L.L.C. FIBER DISTRIBUTION PANEL. PROPOSED DISH Wireless L.L.C. TELCO FIBER ENCLOSURE PROPOSED FIBER NOTE: FIBER PROVIDER NEED TO PROVIDE AN ADDITIONAL ADDITIONAL 5FT UNISTRUT, 1. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING A BID. ANY QUESTIONS ARISING PROPO PROPOSED DISH Wireless L.L.C. PROPOUT UNISTRIN NID, IF REQUIRED 2 U—BOLTS WITH 4 NUTS, DURING THE BID PERIOD IN REGARDS TO THE CONTRACTOR'S FUNCTIONS, THE SCOPE OF WORK, OR ANY THE EVENT THE OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT BRACKET SPACING DOESN'T MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. PROPOSED DISH Wireless LINE UP WITH CURRENT L.L.C. UNISTR SPACING BELOW PROPOSED FIBER PROVIDER IN IN OUT 2. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL ELECTRICAL CODES AND ALL cc /4" FLEX CONDUITS STATE AND LOCAL CODES, LAWS, AND ORDINANCES. PROVIDE ALL COMPONENTS AND WIRING SIZES AS DISH Wireless L.L.C. FIBER1-1 REQUIRED TO MEET NEC STANDARDS. JUMPER TO CABINET WILL FIBER PROVIDER TO TERMINATE FIBER PROVIDER TO PUNCH TOP OF NEED TO BE TERMINATED BY POWER TO FIBER PROVIDER NID TELCO BOX OF NID ENCLOSURE AND 3. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE PROPOSED DISH FIBER PROVIDER ON OTHER SIDE OF BULKHEAD/LC TO LC PROPOSED DISH Wireless L.L.C. INSTALL 1-1/4* LIQUID TIGHT COORDINATED WITH FIELD CONDITIONS PRIOR TO CONSTRUCTION. Wireless L.L.C. CONNECTOR WHERE CIRCUIT 12 AWG WIRE (6' TAIL) CONNECTORS, UL LISTED, NYLON 10 AMP DISTRIBUTION IS TERMINATED. 7774. MATERIAL, WITH 0—RING GASKET 4. CONDUIT ROUGH —IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS. BREAKER VERIFY WITH THE MECHANICAL EQUIPMENT CONTRACTOR AND COMPLY AS REQUIRED. FIBER PROVIDER TO INSTALL 1-1/4" FLEX CONDUITS BETWEEN IN IN PROPOSED DISH Wireless L.L.C. FDP TELCO BOX & NID 5. CONTRACTOR SHALL PROVIDE ALL BREAKERS, CONDUITS AND CIRCUITS AS REQUIRED FOR A COMPLETE SYSTEM. PROPOSED FIBER PROVIDER 10 AMP DISTRIBUTION BREAKER PROPOSED DISH Wireless L.L.C. 0 0 FIBER LATERAL FROM RIGHT PROPOSED DISH Wireless L.L.C. 6. CONTRACTOR SHALL PROVIDE PULL BOXES AND JUNCTION BOXES AS REQUIRED BY THE NEC ARTICLE 314. 12 AWG WIRE OF WAY TO STREET, PROPOSED DISH Wireless L.L.C. TELCO FIBER ENCLOSURE PROPOSED DISH Wireless L.L.C. TERMINATED TO FDP 12 AWG WIRE PROPOSED DISH Wireless L.L.C. 7. CONTRACTOR SHALL PROVIDE ALL STRAIN RELIEF AND CABLE SUPPORTS FOR ALL CABLE ASSEMBLIES. 1-1 /2" POWER FROM CABINET PROPOSED DISH Wireless L.L.C. 1-1 /2" FIBER TO CABINET INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 1-1/2- FIBER TO CABINET N DISH Wireless L.L.C. INSTALLS 1 1-1 /2" CONDUITS FOR P PROPOSED DISH Wireless L.L.C. PROPOSED DISH Wireless L.L.C. PROPOSED DISH Wireless L.L.C. 8. ALL DISCONNECTS AND CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED PHENOLIC NAMEPLATES BER TO CABINET AND FIBER 2" CONDUIT FROM COMMERCIAL 1-1/2- POWER FROM CABINET 42" CONDUIT FROM COMMERCIAL INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM. FIBER VAULT FIBER VAULT 9. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC 250. THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL BOXES, AND ALL DARK TELCO BOX - INTERIOR WIRING LAYOUT NO SCALE 2 LIT TELCO BOX - INTERIOR WIRING LAYOUT (OPTIONAL) NO SCALE 3 DISCONNECT SWITCHES, AND EQUIPMENT CABINETS. 10. ALL NEW MATERIAL SHALL HAVE A U.L. LABEL. 11. PANEL SCHEDULE LOADING AND CIRCUIT ARRANGEMENTS REFLECT POST —CONSTRUCTION EQUIPMENT. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR AS —BUILT PANEL SCHEDULE AND SITE DRAWINGS. ELECTRICAL NOTES I NO SCALE 1 1 1 NOT USED I NO SCALE 1 4 1 NOT USED I NO SCALE 1 5 NOT USED I NO SCALE 1 6 1 NOT USED I NO SCALE 1 7 1 NOT USED I NO SCALE 1 8 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B.� 1 j' pE WA Sy�FA 0 56 58 `vim O� �FGISTE FSS/O NAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE ELECTRICAL DETAILS SHEET NUMBER E-2 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 INSTALL 200A, 120/208V, 1 PH, 3W CHECK METER EXISTING UTILITY METER EXISTING UTILITY 1..1J PADMOUNT TRANSFORMER EXISTING 2000A, 480/277V, OUTSIDE BUILDING 4W SWITCHBOARD ----------------------------f2PH, ELECTRICAL ROOM (BALCONY LEVEL) --------------- I J 2000A I I 400A, 70A, 150A, ) ) 150A, ) 150A, ) 400A, 450A, 450A, ) ) ) I I 3P 3P 3P 3P 3P 3P 3P 3P I I EXISTING I I I "NP-1" 300kVA I I J J 1 200A I I 200A, 2P I I I �I JI EXISTING PANEL "N2BL1 " zl 1200A, 120/208V, 3PH, 4W oI JI INSTALL 200A, 208V, 2P m CIRCUIT BREAKER TO MATCH EXISTING o 3-#3/0 THHN PLUS #6 GROUND IN 2" EMT CONDUIT J uIn FyIo c~.i 10 _l0 1111� M UTILITY SERVICE ENTRANCE 120/240 VAC 1PH GENERATOR 200A CAMLOCK GEN PLUG N SURGE SUPPRESSION DEVICE 100KA SAD/MOV GFCI 01 15A 03 15A 05 SPACE 07 SPACE 09 SPACE II SPACE 13 SPACE 15 SPACE 17 SPACE 19 SPACE 21 SPACE 23 SPACE PROPOSED POWER PROTECTIVE CABINET 120/24OV, 1 PH, SERVICE RATED, OVERALL UL LISTED POWER CENTER, N3R, 65K/10K AIC MAIN BREAKER WITH 200A INTERLOCKED GENERATOR FEED, 200A 65K AIC 04 30A PROPOSED 2 #10, 1 #10 CU GND. ew PROPOSED 2 #10 \ 0 . 1 100 e� PROPOSED 2 #10, 1 #10 CU GND. - � 30 . 16 PROPOSED 2 #10 SPACE SPACE S CAP E S CAP E PROPOSED 2 #10, 1 #10 CU GND. (2) PROPOSED 0.75" EMT CONDUITS (1) PROPOSED 0.5" EMT CONDUIT NOTES THE (2) CONDUITS WITH (4) CURRENT CARRYING CONDUCTORS EACH, SHALL APPLY CHARLES NETWORK CABINET THE ADJUSTMENT FACTOR 12020 OF 80X PER 2014/17 NEC TABLE 310.15(B)(3)(a) OR NEC TABLE 310.15(C)(1) FOR UL1015 WIRE. #12 FOR 15A-20A/1 P BREAKER: 0.8 x 30A = 24.OA #10 FOR 25A-30A/2P BREAKER: 0.8 x 40A = 32.OA #8 FOR 35A-40A/2P BREAKER: 0.8 x 55A = 44.OA #6 FOR 45A-60A/2P BREAKER: 0.8 x 75A = 60.OA FOR RECTIFIER 1 FOR RECTIFIER 2 FOR RECTIFIER 3 FOR RECTIFIER 4 FOR CONVENIENCE OUTLET NOTE: BRANCH CIRCUIT WIRING SUPPLYING RECTIFIERS ARE TO BE RATED UL1015, 105-C, 60OV, AND PVC INSULATED, IN THE SIZES SHOWN IN THE ONE -LINE DIAGRAM. CONTRACTOR MAY SUBSTITUTE UL1015 WIRE FOR THWN-2 FOR CONVENIENCE OUTLET BRANCH CIRCUIT. BREAKERS REQUIRED: (4) 30A, 2P BREAKER —SQUARED P/N:Q023O (1) 15A, 1 P BREAKER —SQUARED P/N:QO115 PPC ONE -LINE DIAGRAM PROPOSED CHARLES PANEL SCHEDULE LOAD SERVED VOLT AMPS (WATTS) TRIP C# PHASE CKT TRIP VOLT AMPS (WATTS) LOAD SERVED L1 L2 L1 L2 PPC GFCI OUTLET 180 15A 1 A 2 30A 2880 ABB/GE INFINITY 2880 RECTIFIER 1 CHARLES GFCI OUTLET 180 15A 3 B 4 -SPACE- 5 A 6 30A 2880 ABB/GE INFINITY 2880 RECTIFIER 2 -SPACE- 7 B 8 -SPACE- 9 A 10 30A 2880 ABB/GE INFINITY 2880 RECTIFIER 3 -SPACE- 11 B 12 -SPACE- 13 A 14 30A 2880 ABB/GE INFINITY 2880 RECTIFIER 4 -SPACE- 15 B 16 -SPACE- 17 A 18 -SPACE- -SPACE- 19 B 20 -SPACE- -SPACE- 21 A 22 -SPACE- -SPACE- 23 B 0241 1 -SPACE- VOLTAGE AMPS 1 180 1 180 111520 111520 200A MCB, 10, 24 SPACE, 120 240V L1 L2 MB RATING: 65,000 AIC 11700 11700 VOLTAGE AMPS 98 98 AMPS 98 IMAX AMPS 123 1 MAX 125X CONDUIT SIZING: AT 4OX FILL PER NEC CHAPTER 9, TABLE 4, ARTICLE 358. 0.5" CONDUIT - 0.122 SQ. IN AREA 0.75" CONDUIT - 0.213 SQ. IN AREA 2.0" CONDUIT - 1.316 SQ. IN AREA 3.0" CONDUIT - 2.907 SQ. IN AREA CABINET CONVENIENCE OUTLET CONDUCTORS (1 CONDUIT): USING THWN-2, CU. #10 - 0.0211 SQ. IN X 2 = 0.0422 SQ. IN #10 - 0.0211 SQ. IN X 1 = 0.0211 SQ. IN <GROUND TOTAL = 0.0633 SQ. IN 0.5" EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (3) WIRES, INCLUDING GROUND WIRE, AS INDICATED ABOVE. RECTIFIER CONDUCTORS (2 CONDUITS): USING UL1015, CU. #10 - 0.0266 SQ. IN X 4 = 0.1064 SQ. IN #10 - 0.0062 SQ. IN X 1 = 0.0082 SQ. IN <BARE GROUND TOTAL = 0.1146 SQ. IN 0.75" EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (5) WIRES, INCLUDING GROUND WIRE, AS INDICATED ABOVE. PPC FEED CONDUCTORS (1 CONDUIT): USING THWN, CU. 3/0 - 0.2679 SQ. IN X 3 = 0.8037 SQ. IN #6 - 0.0507 SQ. IN X 1 = 0.0507 SQ. IN <GROUND TOTAL = 0.8544 SQ. IN 3.0" SCH 40 PVC CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (4) WIRES, INCLUDING GROUND WIRE, AS INDICATED ABOVE. NO SCALE I 1 PANEL SCHEDULE I NO SCALE 1 2 1 NOT USED I NO SCALE 1 3 S l . 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B.� 1 j' pE WAS 0 0 56058 `vim O� �FCISTE FSS/ONAL��� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE ELECTRICAL ONE -LINE, FAULT CALCS & PANEL SCHEDULE SHEET NUMBER E-3 DISH Wireless L.L.C. TEMPLATE VERSION 40 - 08/13/2021 GROUNDING PLAN 4' 2' 0 4' 8' 1 4"=1'-099 EXOTHERMIC CONNECTION ■ MECHANICAL CONNECTION GROUND BUS BAR OGROUND ROD TEST ROD �T IN ECTIONNSLEEVE WITH — — — — — — #6 AWG STRANDED & INSULATED — — #2 AWG SOLID COPPER TINNED BUSS BAR INSULATOR GROUNDING LEGEND 1. GROUNDING IS SHOWN DIAGRAMMATICALLY ONLY. 2. CONTRACTOR SHALL GROUND ALL EQUIPMENT AS A COMPLETE SYSTEM. GROUNDING SHALL BE IN COMPLIANCE WITH NEC SECTION 250 AND DISH Wireless L.L.C. GROUNDING AND BONDING REQUIREMENTS AND MANUFACTURER'S SPECIFICATIONS. 3. ALL GROUND CONDUCTORS SHALL BE COPPER; NO ALUMINUM CONDUCTORS SHALL BE USED. 4. NO EXOTHERMIC WELDING ON ROOFTOP GROUNDING ROOFTOP KEY NOTES OA EXTERIOR GROUND RING: #2 AWG SOLID COPPER, BURIED AT A DEPTH OF AT LEAST 30 INCHES BELOW GRADE, OR 6 INCHES BELOW THE FROST LINE AND APPROXIMATELY 24 INCHES FROM THE EXTERIOR WALL OR FOOTING. (D ROOFTOP GROUND SYSTEM: THE GROUND SYSTEM USING MINIMUM #2 AWG SOLID COPPER CONDUCTORS. OC INTERIOR GROUND RING! #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR EXTENDED AROUND THE PERIMETER OF THE EQUIPMENT AREA. ALL NON —TELECOMMUNICATIONS RELATED METALLIC OBJECTS FOUND WITHIN A SITE SHALL BE GROUNDED TO THE INTERIOR GROUND RING WITH #6 AWG STRANDED GREEN INSULATED CONDUCTOR. OBOND TO INTERIOR GROUND RING: #2 AWG SOLID TINNED COPPER WIRE PRIMARY BONDS SHALL BE PROVIDED AT LEAST AT FOUR POINTS ON THE INTERIOR GROUND RING, LOCATED AT THE CORNERS OF THE BUILDING OR ROOM. OGROUND ROD: UL LISTED COPPER CLAD STEEL. MINIMUM 1 /2" DIAMETER BY EIGHT FEET LONG. GROUND RODS SHALL BE INSTALLED WITH INSPECTION SLEEVES. GROUND RODS SHALL BE DRIVEN TO THE DEPTH OF GROUND RING CONDUCTOR. OCELL REFERENCE GROUND BAR (CRC POINT OF GROUND REFERENCE FOR ALL COMMUNICATIONS EQUIPMENT FRAMES. ALL BONDS ARE MADE WITH #2 AWG UNLESS NOTED OTHERWISE STRANDED GREEN INSULATED COPPER CONDUCTORS. BOND TO COMMON BUILDING GROUND SYSTEM WITH (2) #2 SOLID TINNED COPPER CONDUCTORS. OHATCH PLATE GROUND BAR: BOND TO THE COMMON BUILDING GROUND SYSTEM WITH TWO #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTORS. WHEN A HATCH —PLATE AND A CELL REFERENCE GROUND BAR ARE BOTH PRESENT, THE CRGB MUST BE CONNECTED TO THE HATCH —PLATE AND TO THE INTERIOR GROUND RING USING (2) TWO #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTORS EACH. OEXTERIOR CABLE ENTRY PORT GROUND BARS: LOCATED AT THE ENTRANCE TO THE CELL SITE ROOM. BOND TO GROUND RING WITH A #2 AWG SOLID TINNED COPPER CONDUCTORS WITH MECHANICAL CONNECTIONS. Oj TELCO GROUND BAR: BOND TO BOTH CELL REFERENCE GROUND BAR OR EXTERIOR GROUND RING. OFRAME BONDING: THE BONDING POINT FOR TELECOM EQUIPMENT FRAMES SHALL BE THE GROUND BUS THAT IS NOT ISOLATED FROM THE EQUIPMENTS METAL FRAMEWORK. OINTERIOR UNIT BONDS: METAL FRAMES, CABINETS AND INDIVIDUAL METALLIC UNITS LOCATED WITH THE AREA OF THE INTERIOR GROUND RING REQUIRE A #6 AWG STRANDED GREEN INSULATED COPPER BOND TO THE INTERIOR GROUND RING. OFENCE AND GATE GROUNDING: METAL FENCES SHALL BE BONDED TO THE COMMON BUILDING GROUND SYSTEM WITH A #2 AWG SOLID TINNED COPPER CONDUCTOR AT AN INTERVAL NOT EXCEEDING 25 FEET. BONDS SHALL BE MADE AT EACH GATE POST AND ACROSS GATE OPENINGS. OEXTERIOR UNIT BONDS: METALLIC OBJECTS, EXTERNAL TO OR MOUNTED TO THE BUILDING, SHALL BE BONDED TO THE COMMON BUILDING GROUND SYSTEM. USING #2 TINNED SOLID COPPER WIRE GICE BRIDGE SUPPORTS: EACH ICE BRIDGE LEG SHALL BE BONDED TO THE GROUND RING WITH #2 AWG BARE TINNED COPPER CONDUCTOR. PROVIDE EXOTHERMIC WELDS AT BOTH THE ICE BRIDGE LEG AND BURIED GROUND RING. OO DURING ALL DC POWER SYSTEM CHANGES INCLUDING DC SYSTEM CHANGE OUTS, RECTIFIER REPLACEMENTS OR ADDITIONS, BREAKER DISTRIBUTION CHANGES, BATTERY ADDITIONS, BATTERY REPLACEMENTS AND INSTALLATIONS OR CHANGES TO DC CONVERTER SYSTEMS IT SHALL BE REQUIRED THAT SERVICE CONTRACTORS VERIFY ALL DC POWER SYSTEMS ARE EQUIPPED WITH A MASTER DC SYSTEM RETURN GROUND CONDUCTOR FROM THE DC POWER SYSTEM COMMON RETURN BUS DIRECTLY CONNECTED TO THE CELL SITE REFERENCE GROUND BAR OP ROOFTOP COLLECTOR BUSS BAR IS TO BE MECHANICALLY BONDED TO COMMON BUILDING GROUND SYSTEM. REFER TO DISH Wireless L.L.C. GROUNDING NOTES. GROUNDING KEY NOTES NO SCALE I 2 wirel 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 �01 L B. 4 1 j'oE WASy�F0 0 56058 `vim O� �FGISTE FSS/ONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA-98020 SHEET TITLE GROUNDING PLANS AND NOTES SHEET NUMBER G-1 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 12" 6" 0 TYPICAL ANTENNA GROUNDING DETAIL MAIN GROUND CONDUIT RUN FROM EXISTING BUILDING GROUND IN ELECTRICAL ROOM ON BALCONY LEVEL (LENGTH: 85-0"f). REFER TO G-1 FOR CONTINUATION EQUIPMENT QUIRED BY ACTURER, TYP. SED H—FRAME 0 /4" TINNED R GROUND BUSSBAR kYOUT IS ONLY 1' 2' 3' 4' 5' 1 2"=1 ' —0" 1 PROPOSED DISH Wireless 1 1 ^ r%^t&iram TINNED COPPER GROUND BUSSBAR MAIN GROUND CONDUIT RUN FROM EXISTING BUILDING GROUND IN ELECTRICAL ROOM ON BALCONY LEVEL (LENGTH: 85-0"f). REFER TO G-1 FOR CONTINUATION H-FRAME GROUNDING DETAIL NOTE EQUIPMENT CABINET OMITTED FOR CLARITY NO SCALE I 2 Sel!, 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 r CORE ONE CONSULTING USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 to' B. 4 i %oF waSyFFo p Z rB 56058 �<v� FSSIONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE GROUNDING DETAILS SHEET NUMBER G-2 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 1. EXOTHERMIC WELD (2) TWO, #2 AWG BARE TINNED SOLID COPPER CONDUCTORS TO GROUND BAR. ROUTE CONDUCTORS TO BURIED GROUND RING AND PROVIDE PARALLEL EXOTHERMIC WELD. 2. ALL EXTERIOR GROUNDING HARDWARE SHALL BE STAINLESS STEEL 3/8" DIAMETER OR LARGER. ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING LOCK WASHERS, COAT ALL SURFACES WITH AN ANTI -OXIDANT COMPOUND BEFORE MATING. 3. FOR GROUND BOND TO STEEL ONLY: COAT ALL SURFACES WITH AN ANTI -OXIDANT COMPOUND BEFORE MATING. 4. DO NOT INSTALL CABLE GROUNDING KIT AT A BEND AND ALWAYS DIRECT GROUND CONDUCTOR DOWN TO GROUNDING BUS. 5. NUT & WASHER SHALL BE PLACED ON THE FRONT SIDE OF THE GROUND BAR AND BOLTED ON THE BACK SIDE. 6. ALL GROUNDING PARTS AND EQUIPMENT TO BE SUPPLIED AND INSTALLED BY CONTRACTOR. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ADDITIONAL GROUND BAR AS REQUIRED. 8. ENSURE THE WIRE INSULATION TERMINATION IS WITHIN 1 /8" OF THE BARREL (NO SHINERS). BASE # 2 GROU TO CABLE TRAY/SUPPORT GROUND BUSS BAR TYPICAL GROUNDING NOTES I NO SCALE 1 1 1 OUTDOOR CABINET GROUNDING I NO SCALE 1 2 NOTE: MINIMUM OF 3 THREADS TO BE VISIBLE (TYP) 2 HOLE LONG BARREL TINNED SOLID COPPER LUG (TYP) TIN COATED SOLID COPPER BUS BAR CHERRY INSULATOR INSTALLED IF REQUIRED S/S BOLT (TYP) S/S SPLIT WASHER (TYP) S/S FLAT WASHER (TYP) S/S FLAT WASHER (TYP) S/S NUT (TYP) CABLE TRAY CHERRY INSULATOR, INSTALLED IF REQUIRED TIN COATED SOLID COPPER BUS BAR SLEEPER EXISTING BUILDING ROOFTOP #2 STRANDED INSULATES COPPER GROUNDING WIRE TO MAIN BUS BAR (TYP) CABLE TRAY EXISTING BUILDING ROOFTOP ---, #2 STRANDED INSULATES COPPER GROUNDING WIRE FROM CABLE (TYP) CHERRY INSULATOR, INSTALLED IF REQUIRED - r•. • GROUNDING JUMPER CABLE TRAY JOINTS (TYP) 2-HOLE LONG BARREL TINNED SOLID COPPER LUG (TYP) TIN COATED SOLID COPPER BUS BAR TYPICAL CABLE TRAY GROUND BUSS BAR NO SCALE I 3 EXTERNAL CLOSED BARREL, FOR ALL BLACK HEAT CONDUCTOR INSULATION TO EXTERNAL INSPECTION WINDOW IN CLEAR HEAT CONDUCTOR INSULATION TO TOOTHED EXTERIOR TWO -HOLE SHRINK UV BUTT UP AGAINST THE TOOTHED BARREL, REQUIRED FOR SHRINK7 BUTT UP AGAINST THE CONNECTORS RATED CONNECTOR BARREL ALL INTERIOR TWO -HOLE CONNECTOR BARREL CONNECTORS 3/8" DIA x1 1/2"--% 3/8" DIA x1 1/2"---j S/S NUT S/S LOCK WASHER - S/S FLAT WASHER - S/S FLAT WASHER- S/S BOLT (1 OF 2)- 1 /16" MINIMUM SPACING S/S NUT S/S LOCK WASHER - S/S FLAT WASHER - S/S FLAT WASHER- S/S BOLT (1 OF 2) 1/16" MINIMUM SPACING 11111� TINNED COPPER ---------- GROUNDING BAR ---- - - - - - - 111111IL LUG DETAIL I NO SCALE 1 4 1 TYPICAL EXTERIOR TWO HOLE LUG I NO SCALE 1 5 1 TYPICAL INTERIOR TWO HOLE LUG I NO SCALE 1 6 NOT USED [ 'IT If] I &*aTQia �A NOT USED I NO SCALE 1 8 1 NOT USED I NO SCALE 1 9 (i S wirel . 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 COREI ONE gj)- NSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 0�LB.� 1 j'pE WAS 'o 0 56058 `vim FSS�ONAL��� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE GROUNDING DETAILS SHEET NUMBER G-3 DISH Wireless L.L.C. TEMPLATE VERSION 40 - 08/13/2021 R F JUMPER COLOR CODING 3/4" TAPE WIDTHS WITH 3/4" SPACING ALPHA RRH BETA RRH GAMMA RRH PORT 1 PORT 2 PORT 3 PORT 4 PORT 1 PORT 2 PORT 3 PORT 4 PORT 1 PORT 2 PORT 3 PORT 4 LOW -BAND RRH - + SLANT - SLANT + SLANT - SLANT + SLANT - SLANT + SLANT - SLANT + SLANT - SLANT + SLANT - SLANT (60OMHz N71 BASEBAND) + (850MHz N26 BAND) + (70OMHz N29 BAND) - OPTIONAL PER MARKET RED RED RED RED BLUE BLUE BLUE BLUE GREEN GREEN GREEN GREEN ORANGE ORANGE RED RED ORANGE ORANGE BLUE BLUE ORANGE ORANGE GREEN GREEN ADD FREQUENCY COLOR TO SECTOR BAND (CBRS WILL USE YELLOW BANDS) WHITE ORANGE ORANGE WHITE ORANGE ORANGE WHITE ORANGE ORANGE WHITE WHITE WHITE RED RED RED RED BLUE BLUE BLUE BLUE GREEN GREEN GREEN GREEN MID -BAND RRH - (AWS BANDS N66+N70) PURPLE PURPLE RED RED PURPLE PURPLE BLUE BLUE PURPLE PURPLE GREEN GREEN WHITE PURPLE PURPLE _WHO PURPLE PURPLE _WHITE PURPLE PURPLE ADD FREQUENCY COLOR TO SECTOR BAND (CBRS WILL USE YELLOW BANDS) WHITE WHITE WHITE HYBRID/DISCREET CABLES EXAMPLE 1 EXAMPLE 2 EXAMPLE 3 RED RED INCLUDE SECTOR BANDS BEING SUPPORTEDBLUE BLUEALONG iiG WITH FREQUENCY BANDS GREEN GREEN OE EXAMPLE 1 — HYBRID, OR DISCREET, SUPPORTS PURPLE ALL SECTORS, BOTH LOW —BANDS AND MID —BANDS ORANGE YELLOW PURPLE EXAMPLE 2 — HYBRID, OR DISCREET, SUPPORTS CBRS ONLY, ALL SECTORS FIBER JUMPERS TO RRHs LOW BAND RRH HIGH BAND RRH LOW BAND RRH HIGH BAND RRH LOW BAND RRH HIGH BAND RRH LOW -BAND RRH FIBER CABLES HAVE SECTOR STRIPE ONLY RED RED BLUE BLUE GREEN GREEN PURPLE PURPLE PURPLE POWER CABLES TO RRHs LOW BAND RRH HIGH BAND RRH LOW BAND RRH HIGH BAND RRH LOW BAND RRH HIGH BAND RRH LOW -BAND RRH POWER CABLES HAVE SECTOR STRIPE ONLY R BLUE BLUE GREEN GREEN PURPLE PURPLE PURPLE RET MOTORS AT ANTENNAS ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 LOW BAND/ HIGH BAND/ LOW BAND/ HIGH BAND/ LOW BAND/ HIGH BAND/ "IN" "IN" "IN" "IN" "IN" "IN" RED RED BLUE BLUE GREEN GREEN PURPLE PURPLE PURPLE MICROWAVE RADIO LINKS FORWARD AZIMUTH OF 0-120 DEGREES FORWARD AZIMUTH OF 120-240 DEGREES FORWARD AZIMUTH OF 240-360 DEGREES LINKS WILL HAVE A 1.5-2 INCH WHITE WRAP WITH PRIMARY SECONDARY PRIMARY SECONDARY PRIMARY SECONDARY THE AZIMUTH COLOR OVERLAPPING IN THE MIDDLE. ADD ADDITIONAL SECTOR COLOR BANDS FOR EACH ADDITIONAL VW RADIO. WHITE WHITE WHITE WHITE WHITE WHITE RED RED BLUE BLUE GREEN GREEN MICROWAVE CABLES WILL REQUIRE P—TOUCH LABELS INSIDE THE CABINET TO IDENTIFY THE WHITE WHITE WHITE WHITE WHITE WHITE LOCAL AND REMOTE SITE ID'S RED BLUE GREEN WHITE WHITE WHITE RF CABLE COLOR CODES 1,r•1*OT >11 LOW BANDS (N71 +N26) OPTIONAL — (N29) ORANGE CBRS TECH (3 GHz) YELLOW ALPHA SECTOR RED BETA SECTOR BLUE AWS (N66+N70+H—BLOCK) PURPLE NEGATIVE SLANT PORT ON ANT/RRH WHITE GAMMA SECTOR GREEN COLOR IDENTIFIER I NO SCALE 1 2 NOT USED I NO SCALE 1 3 1 1 NOT USED I NO SCALE 1 4 vwm e r 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B.� 1 j'oE WAS 'o 0 56058 `vim O� �FGISTE F'sSIO NAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE RF CABLE COLOR CODE SHEET NUMBER RF-1 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021 AB ANCHOR BOLT IN INCH EXOTHERMIC CONNECTION ABV ABOVE INT INTERIOR MECHANICAL CONNECTION ■ AC ALTERNATING CURRENT LB(S) POUND(S) BUSS BAR INSULATOR A ADDL ADDITIONAL LF LINEAR FEET CHEMICAL ELECTROLYTIC GROUNDING SYSTEM e AFF ABOVE FINISHED FLOOR LTE LONG TERM EVOLUTION AFG ABOVE FINISHED GRADE MAS MASONRY TEST CHEMICAL ELECTROLYTIC GROUNDING SYSTEM e T AGL ABOVE GROUND LEVEL MAX MAXIMUM EXOTHERMIC WITH INSPECTION SLEEVE Q AIC AMPERAGE INTERRUPTION CAPACITY MB MACHINE BOLT GROUNDING BAR ALUM ALUMINUM MECH MECHANICAL ALT ALTERNATE MFR MANUFACTURER GROUND ROD 1II--� ANT ANTENNA MGB MASTER GROUND BAR TEST GROUND ROD WITH INSPECTION SLEEVE 11 T APPROX APPROXIMATE MIN MINIMUM ARCH ARCHITECTURAL MISC MISCELLANEOUS SINGLE POLE SWITCH ATS AUTOMATIC TRANSFER SWITCH MTL METAL AWG AMERICAN WIRE GAUGE MTS MANUAL TRANSFER SWITCH DUPLEX RECEPTACLE BATT BATTERY MW MICROWAVE BLDG BUILDING NEC NATIONAL ELECTRIC CODE DUPLEX GFCI RECEPTACLE BLK BLOCK NM NEWTON METERS BLKG BLOCKING NO. NUMBER FLUORESCENT LIGHTING FIXTURE (2) TWO LAMPS 48-T8 r -I F I I BM BEAM # NUMBER BTC BARE TINNED COPPER CONDUCTOR NTS NOT TO SCALE SMOKE DETECTION (DC) SD BOF BOTTOM OF FOOTING OC ON -CENTER CAB CABINET OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION EMERGENCY LIGHTING (DC) CANT CANTILEVERED OPNG OPENING CHG CHARGING P/C PRECAST CONCRETE SECURITY LIGHT W/PHOTOCELL LITHONIA ALXW CLG CEILING PCs PERSONAL COMMUNICATION SERVICES LED-1-25A400/51 K-SR4-120-PE-DDBTXD CLR CLEAR PCU PRIMARY CONTROL UNIT COL COLUMN CHAIN LINK FENCE X X X X PRC PRIMARY RADIO CABINET COMM COMMON PP POLARIZING PRESERVING WOOD/WROUGHT IRON FENCE CONC CONCRETE PSF POUNDS PER SQUARE FOOT WALL STRUCTURE CONSTR CONSTRUCTION PSI POUNDS PER SQUARE INCH DBL DOUBLE LEASE AREA _ _ PT PRESSURE TREATED DC DIRECT CURRENT PWR POWER CABINET PROPERTY LINE (PL) - - - - - - DEPT DEPARTMENT QTY QUANTITY SETBACKS - - - - - - - - - - - - - - - - - - - - - - - - - DF DOUGLAS FIR RAD RADIUS DIA DIAMETER ICE BRIDGE RECT RECTIFIER DIAG DIAGONAL REF REFERENCE CABLE TRAY DIM DIMENSION REINF REINFORCEMENT WATER LINE W W W W W DWG DRAWING REQ'D REQUIRED DWL DOWEL UNDERGROUND POWER UGP UGP UGP UGP UGP EA EACH RET REMOTE ELECTRIC TILT RF RADIO FREQUENCY UNDERGROUND TELCO UGT UGT UGT UGT UGT EC ELECTRICAL CONDUCTOR RMC RIGID METALLIC CONDUIT OVERHEAD POWER OHP OHP OHP OHP EL. ELEVATION RRH REMOTE RADIO HEAD ELEC ELECTRICAL OVERHEAD TELCO OHT OHT OHT OHT EMT ELECTRICAL METALLIC TUBING RRU REMOTE RADIO UNIT RWY RACEWAY UNDERGROUND TELCO/POWER UGT/P UGT/P UGT/P UGT/P ENG ENGINEER SCH SCHEDULE ABOVE GROUND POWER AGP AGP AGP AGP AGP EQ EQUAL SHT SHEET EXP EXPANSION ABOVE GROUND TELCO AGT AGT AGT AGT AGT EXT EXTERIOR SIAD SMART INTEGRATED ACCESS DEVICE SIM SIMILAR ABOVE GROUND TELCO/POWER AGT/P AGT/P AGT/P AGT/P EW EACH WAY SPEC SPECIFICATION FAB FABRICATION WORKPOINT W.P. SQ SQUARE FF FINISH FLOOR SS STAINLESS STEEL rxx_"*� FG FINISH GRADE SECTION REFERENCE X_X STD STANDARD FIF FACILITY INTERFACE FRAME STL STEEL FIN FINISHED) TEMP TEMPORARY FLR FLOOR THK THICKNESS DETAIL REFERENCE X FDN FOUNDATION TMA TOWER MOUNTED AMPLIFIER �_x FOC FACE OF CONCRETE TN TOE NAIL FOM FACE OF MASONRY TOA TOP OF ANTENNA FOS FACE OF STUD TOC TOP OF CURB FOW FACE OF WALL TOF TOP OF FOUNDATION FS FINISH SURFACE TOP TOP OF PLATE (PARAPET) FT FOOT TOS TOP OF STEEL FTG FOOTING TOW TOP OF WALL GA GAUGE TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION GEN GENERATOR TYP TYPICAL GFCI GROUND FAULT CIRCUIT INTERRUPTER UG UNDERGROUND GLB GLUE LAMINATED BEAM UL UNDERWRITERS LABORATORY GLV GALVANIZED UNO UNLESS NOTED OTHERWISE GPS GLOBAL POSITIONING SYSTEM UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM GND GROUND GSM GLOBAL SYSTEM FOR MOBILE UPS UNITERRUPTIBLE POWER SYSTEM (DC POWER PLANT) HDG HOT DIPPED GALVANIZED VIF VERIFIED IN FIELD HDR HEADER W WIDE HGR HANGER W/ WITH HVAC HEAT/VENTILATION/AIR CONDITIONING WD WOOD HT HEIGHT WP WEATHERPROOF IGR INTERIOR GROUND RING wr WEIGHT LEGEND ABBREVIATIONS wirel 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B.� 1 j'pE WAS 'o 0 56058 `vim O� �FGISTE FSS�ONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE LEGEND AND ABBREVIATIONS SHEET NUMBER GN-1 DISH Wireless L.L.C. TEMPLATE VERSION 40 - 08/13/2021 1. NOTICE TO PROCEED - NO WORK SHALL COMMENCE PRIOR TO CONTRACTOR RECEIVING A WRITTEN NOTICE TO PROCEED (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE DISH Wireless L.L.C. AND TOWER OWNER NOC & THE DISH Wireless L.L.C. AND TOWER OWNER CONSTRUCTION MANAGER. 2. "LOOK UP" - DISH Wireless L.L.C. AND TOWER OWNER SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR DISH Wireless L.L.C. AND DISH Wireless L.L.C. AND TOWER OWNER POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND DISH Wireless L.L.C. AND TOWER OWNER STANDARDS, INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). 5. ALL SITE WORK TO COMPLY WITH DISH Wireless L.L.C. AND TOWER OWNER INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON DISH Wireless L.L.C. AND TOWER OWNER TOWER SITE AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY DISH Wireless L.L.C. AND TOWER OWNER PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES INCLUDING PRIVATE LOCATES SERVICES PRIOR TO THE START OF CONSTRUCTION. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND DISH PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF DISH Wireless L.L.C. AND TOWER OWNER, AND/OR LOCAL UTILITIES. 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS AND RADIOS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. GENERAL NOTES: 1.FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR:GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER:DISH Wireless L.L.C. TOWER OWNER:TOWER OWNER 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CARRIER POC AND TOWER OWNER. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND TOWER OWNER PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION, BEFORE SUBMITTING BIDS, TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF DISH Wireless L.L.C. AND TOWER OWNER 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. r wireiees, 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 f�yB.� 0 56058 `vim O� �FGISTE FSSIONAL��� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE GENERAL NOTES SHEET NUMBER GN-2 DISH Wireless L.L.C. TEMPLATE VERSION 40 - 08/13/2021 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 psf. 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90'f AT TIME OF PLACEMENT. 4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER -TO -CEMENT RATIO (W/C) OF 0.45. 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. ALL SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: #4 BARS AND SMALLER 40 ksi #5 BARS AND LARGER 60 ksi 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: • CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" • CONCRETE EXPOSED TO EARTH OR WEATHER: • #6 BARS AND LARGER 2" • #5 BARS AND SMALLER 1-1/2 • CONCRETE NOT EXPOSED TO EARTH OR WEATHER: • SLAB AND WALLS 3/4" • BEAMS AND COLUMNS 1-1/2 n 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1 /2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. TIE WRAPS ARE NOT ALLOWED. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR, TYPE SOOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR, TYPE TC CABLE (#14 OR LARGER), WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75' C (90' C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3 (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR DISH Wireless L.L.C. AND TOWER OWNER BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "DISH Wireless L.L.C.". 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. r wirer. 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 �01 B. � 1 j' pE WA Sy�FA 0 56058 `vim O� �FGISTE FSSIONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE GENERAL NOTES SHEET NUMBER GN-3 DISH Wireless L.L.C. TEMPLATE VERSION 40 - 08/13/2021 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL -OF -POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 900 BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 450 BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). DO NOT ATTACH GROUNDING TO FIRE SPRINKLER SYSTEM PIPES. • r vwm al 5701 SOUTH SANTA FE DRIVE LITTLETON, CO 80120 rN COREI ONE CONSULTNG USA 13555 SE 36TH ST, SUITE 100 BELLEVUE, WA 98006 B.4 1 j' pE WAS y�Fo 0 56 58 `vim O� �fC/ TE FSSIONAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY: APPROVED BY: AF LC M L RFDS REV #: --- CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION A 12/10/2021 ISSUED FOR REVIEW 8 12/20/2021 REVISED PER COMMENTS C 04/04/2022 REVISED PER COMMENTS 0 04/20/2022 ISSUED FOR CONSTRUCTION A&E PROJECT NUMBER SESEA00426D DISH Wireless L.L.C. PROJECT INFORMATION SESEA00426D 410 4TH AVE N EDMONDS_WA_98020 SHEET TITLE GENERAL NOTES SHEET NUMBER GN-4 DISH Wireless L.L.C. TEMPLATE VERSION 40 — 08/13/2021