REV1 APPROVED 1 BLD2023-0066+Structural Plan+4.5.2023_9.05.48_AM+3463896F
I
7,
--�I
I
I
-------�—
1
I
-----�
I
1
I
I
this entire area is to
be overframed now.
u k=. r
ENGINEERING
LLO,
4303 Stone Way N
Seattle, WA 98103
206.258.6333
REVISION
Apr 05 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
. . . . . . .I
w
I �• I
Roof Framing Plan
N
SCALE: 11=� 1-011 N 6 I CD
4 I I 00
/S5 / ^ > d1
PLAN NOTES LEGEND ! nV ,I Q Q
00
1. REFER TO GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS ( 51.1)
�✓
I j
o STRUCTURAL WOOD WALL or JOIST or BEAM Q �/
2. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS UNLESS SPECIFICALLY NOTED El POST BELOW THIS LEVEL w o X I LL
ON STRUCTURAL PLANS. — — — (E) JOIST OR BEAM I
(E) STRUCTURAL WOOD WALL OR (E)ROOF FRAMING o
()OO
ALL NEW EXTERI R WALL FRAMING HALL BECONSTRUCTED T MEET THE ® POST BELOW THIS LEVEL HD _ HOLDOWN — — — — — — — — — — — — — — (TYP.U.N.O_) — — — — — I ¢„ , Om O
3. 0 GS 0 �:�— — — �� —�
REQUIREMENTS OF A W6 SHEARWALL AS SPECIFIED IN DETAILS 3/54.1 AND 7/54.1. (E) SPAN DIRECTION - — — - STRAP PER PLAN I N E
' I ,
4. ALL NEW HEADERS AT ROOF NOT NOTED OTHERWISE ON PLAN SHALL BE (2) 2x8. (REFER 8 SPAN DIRECTION I I I � N L.U
TO DETAIL 6/54.1)
I W
<eEXTENT OF SPAN J
5. REFER T011/54.1 AT SHEARWALL INTERSECTIONS. I I
(E) ROOFLINE w
I
O
NOTE- Contractor to
verify (E) rafters 16"
o.c. max
O'Leary Residence
SK-1 - Roof to be overFramed
Per Client - 4-4-23
REVISED PLAN APPROVED
CITY OF EDMONDS BUILDING DIVISION
EEritl Cv.�er
HEADER PER PLAN NOTE 4
TYPICAL AT ALL NEW
EXTERIOR WINDOW
LOCATIONS
No. Date Issue
01 /01 /23 Permit
Sheet Contents
ROOF FRAMING PLAN
Sheet No.
BUILDING OFFICIAL BLD2023-0066 S202
Apr 10 2023
APPROVED DATE
8d @ 6" oc
2x6 CONT. W/
(2)16d @ EA. RAFTER
TOP CHORD
(E)RAFTER
REVISION
bula oApr A, 'T
ENGINEERING
c
DATE 04/04/2023 PROJECT O'Leary Residence S K-2
SCALE 3/4" =1'-0" TITLE Over raming Connection
8d @ 6" O.C. INTO
2x BLOCKING
(2)16d TOENAILS
8d @ 6" O.C. INTO
THRU EACH JOIST
2x BLOCKING
(2)16d TOENAILS
THRU EACH JOIST
A35 @ 24" O.C.
SHIM AS REQ'D
RAFTER &SHEATHING
PER PLAN
%" 0 x 8" SDS SCREW
@ 24" O.C. TYP.
(E)ROOF FRAMING
(E)WALL
SHIM AS REQ'D
H1 @ EACH RAFTER
2x6 @ 48" O.C.
'/a" 0 x 3" SDS SCREW
@ 24" O.C. TYP.
(E)ROOF FRAMING
bulc—r
2x BLOCKING
ENGINEERING
«.
DATE
04/04/23
PROJECT
O'Leary
S K-3
SCALE
3/4" =1'-0"
TITLE
(N)Roof and (E)Roof Connection