Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED FIR2023-0089+Fire_Alarm_Plan+9.13.2023_9.57.51_AM+3779889
NOVA FAMILY RESOU RCE CENTER FIRE ALARM INSTALLATION II SEQUENCE OF OPERATIONS I EQUIPMENT LEGEND I SHEET INDEX 7 Il :=7r -r':' SYSTEM OUTPUTS Required Fire Safety Control System Actions Central Station FACP Annunciation SYSTEM INPUTS 1 Manual Pull -Station ♦ ♦ ♦ 1 LL 2 Smoke Detectors ♦ ♦ ♦ ♦ 2 3 Heat Detectors 3 4 Fire Alarm AC Power Failure 4 LU m5 Fire Alarm System Low Battery 5 =O 6 Open Circuit 6 W 7 Ground Fault 7 8 Notification Appliance Circuit Short 8 Nome e7A I0000' ©0 VICINITY MAP r Lynpwoaci �fl Lakea_k . 1; I. �I�OfLynn+�o�o . pal Golf CaJT5E7 21010 76thl Ave W EDMOND , 98026 -- S� A-=tE HEIGHT'S QOpen Rind M010rsl7Cr#S E�m�nds-4�r�s+ay Seattle - High Schfxaf �nlat+�r pa#Itfc Ilrilc' ` =r' `;Y Wr' L r ' Jeff'S Auto Repair - WnCu I avd _ J Sr T-N h � INSTALLATION DETAIL FIRE ALARM INSTALLATION DETAIL FIRE ALARM DEVICE INSTALLATION REQUIREMENTS NOT PERMITTED SUPPORT BRACKET DIFFUSER HERE 4" J-BOX ACT GRID 000 FA DEVICE CEILING DETECTOR SMOKE 71 4" MINIMUM 3' AWAY FROM NOT PERMITTED 12„ HVAC DIFFUSERS HERE SMOKE H/S MAX HEIGHT 92" A.F.F MIN HEIGHT 82" A.F.F 'ffi' I ® o �eoo .__ Q FAA w Its FACP 66" A.F.F 60" A.F.F PULL U) z U_ 48" A.F.F FINISHED FLOOR SYMBOL QTY MANUFACTURER PART NO DESCRIPTION FACP 1 GAMEWELL GWF-7075 ADDRESSABLE FIRE ALARM CONTROL PANEL FAA 1 GAMEWELL RA-1000 REMOTE ANNUNCIATOR AEs 1 AES 7707-88-M WIRELESS COMMERCIAL FIRE ALARM COMMUNICATOR ❑F 1 GAMEWELL MS-7ASF ADDRESSABLE PULL STATION 0 20 GAMEWELL ASD-PL3 / B300-6 BASE ADDRESSABLE, PHOTO, DET. 0135' 4 GAMEWELL ATD-L3R / B300-6 BASE ADDRESSABLE 1357 ROR HEAT DETECTOR 7 SYSTEM SENSOR SCWL STROBE, CEILING, WHITE 12 SYSTEM SENSOR PC2WL HORN/STROBE, CEILING, WHITE WP 2 SYSTEM SENSOR P2RK HORN/STROBE,WP,WALL , RED DOc 1 SPACE AGE SS000674 FIRE ALARM DOCUMENT CABINET 2 DURACELL 12V8AH 12VDC 8AH - FACP BATTERY 1 DURACELL 12V12AH 12VDC 12AH - AES RADIO BATTERY SITE PLAN-nts Approved DFM Chris gust South County Fire Date: 09/28/2023 09-28-2023 PLAN REVIEW NOTES: APPROVED WITH CONDITION: KNOX BOX REQUIRED TO ACCESS ANNUNCIATOR D ESCRIPTIO N PR0, CT D EFAI LS R RE ALARM INSTALLATION PLAN PROJECT DETAILS INSTALLATION OF AN AUTOMATIC FULLY ADDRESSABLE FIRE ALARM SYSTEM WITH OCCUPANT NOTIFICATION IN AN EXISTING 4000sf NON -SPRINKLED TWO STORY BUILDING PER PLAN. INSTALLATION INCLUDES: (1) FACP, (1) AES RADIO COMMUNICATOR, (1) REMOTE ANNUNCIATOR, (1) MANUAL PULL -STATION, (20) PHOTO SMOKE DETECTORS, (4) RATE OF RISE HEAT DETECTORS, AND (21) OCCUPANT NOTIFICATION DEVICES. NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE PROJECT CONTACT INFO TENANT FIRE ALARM CONTRACTOR NOVA FAMILY RESOURCE CENTER FIRE PROTECTION INC. 21010 76th Ave W. 17410 ASH WAY, Ste 8 EDMONDS, WA 98026 LYNNWOOD, WA 98037 CONTACT : CAROLE HARPER CONTACT : DAVID MOW PHONE : 425.214.2493 PHONE : 425.290.9600 CAROLEH@NOVAFAM.ORG DAVID@FPISEATTLE.COM PROJECT CODE INFO AUTHORITY HAVING JURISDICTION : CITYOFEDMONDS/ SOUTH SNOHOMISH COUNTY RREAUTHORITY BUILDING CODE: INTERNATIONAL BUILDING CODE, 2018 EDITION RRECODE: INTERNATIONAL RRECODE, 2018 EDITION EDMONDSMUNICIPAL CODE/ SOUTH SNOHOMISH COUNTY RREAUTHORITY STANDARDS BUILDING USEAND OCCUPANCY: GROUP NON -CRINKLED STANDARDS 2017 NFPA 70, 2016 NFPA 72, CITY OFEDMOND$ SOUTH SNOHOMISH COUNTY RREAUTHORITY CLASSRCATION OFSUPERVISNG STATION : REVIOTESUPERVISNG STATION REMOTE SUPERVISNG STATION : SECURITAS, LACEY WA UL LISTED PRIMERREALARM CONTRACTOR: FIRE PROTECTION INC PARCEL TAX ID NUMBER: 00614300001604 INSTALLATION NOTES FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM ROY L CATS Lill lu- �� NFPA �a CFPS � #1473 0 w H LO w w LO cn U LU w Z V CO Cl)Cn a I— O O V O w ��oLLCO> z—j �:_ 2 wLU 0. 0 w- � 0WWof Q 0zofcn_j0. 0 REVISION RECORD DATE / DESCRIPTION 1. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. 2. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. FIR2023-0089 3. CABLE ROUTING SHOWN ON DRAWINGS IS FOR INTENT. EXACT ROUTING TO BE COORDINATED WITH OTHER TRADES IN THE FIELD. SEE SPECIFICATIONS AND DRAWING NOTES FOR ACCEPTABLE INSTALLATION METHODS. SEE WIRING LEGEND FOR CABLE TYPES AND SIZES. 4. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING RECEIVED SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR Sep 13 2023 HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. CITY OFEDMONDS DEVELOPMENT SERVICES 5. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATIONS THROUGH FIRE -RATED CONSTRUCTION. DEPARTMENT 6. POWER -LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN THE CABINET. ALL POWER -LIMITED DATE: 09.01.23 CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NON -POWER LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NON -POWER LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT PROJECT NAME KNOCK OUTS AND/OR SEPARATE CONDUITS. 7. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. CABLES USED IN VERTICAL RUNS SHALL BE TYPE FPLR. CABLE SPLICES OR TERMINATIONS SHALL BE MADE IN LISTED FITTINGS, BOXES, ENCLOSURES, FIRE ALARM DEVICES, OR UTILIZATION EQUIPMENT. WHERE INSTALLED EXPOSED, LV CABLES SHALL BE ADEQUATELY SUPPORTED AND INSTALLED IN SUCH A WAY THAT PROTECTION AGAINST PHYSICAL DAMAGE IS AFFORDED BY BUILDING CONSTRUCTION. WHERE EXPOSED CABLE IS LOCATED WITHIN 7 FT OF THE FLOOR, IT Z SHALL BE RUN IN RACEWAY. LU 8. WALL MOUNTED STROBES SHALL BE PLACED 80" MINIMUM TO 96" MAXIMUM ABOVE FLOOR LEVEL. (NFPA72 18.5.4.1 V N & 2). WALL MOUNTED STROBES SHALL BE SIZED IN ACCORDANCE WITH (NFPA72 TABLE 18.5.4.3.1(A). CEILING W c:li MOUNTED STROBES SHALL BE PLACED AND SIZED IN ACCORDANCE WITH (NFPA-72 TABLE 18.5.4.3.1(B). 0 0 Go 9. WHEN MORE THAN TWO NOTIFICATION APPLIANCES ARE VISIBLE AT THE SAME TIME WHETHER THEY ARE IN THE > Q SAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEW, THE FLASH OF THOSE STROBES SHALL BE O SYNCHRONIZED (NFPA-72, SECTION 18.5.4.3.2(3) & (4). W 10. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE W ti 0 AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). ALL INITIATING DEVICES AND DEVICES CONTAINING EOL'S >. CD Z SHALL HAVE A PHYSICAL LABEL IDENTIFYING THE DEVICE'S ADDRESS / END OF LINE RESISTOR. J_ C O 11. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD DRAWINGS Q N 0 OTHERWISE REFERRED TO AS ("AS -BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE KEPT IN THE FIRE ALARM LL W DOCUMENT CABINET NEXT TO THE FACP (NFPA-72 10.18.2.3). Q 12. PRIOR TO CALLING FOR INSPECTION, THE INSTALLER SHALL PROVIDE DOCUMENTATION TO THE LOCAL AHJ STATING i THAT THE SYSTEM HAS BEEN INSTALLED, TESTED, EVALUATED AND CONFIRMED TO BE IN ACCORDANCE WITH ALL O GOVERNING CODES AND THE APPROVED PLANS. THE FIRE ALARM SYSTEM INSTALLER SHALL COMPLETE AN Z NFPA-72 RECORD OF COMPLETION (NFPA-72 10.18.2.1.1). ABBREVIATIONS USED IN THE DRAWINGS SHEET TITLE AHJ AUTHORITY HAVING JJRISDICTION N 1 NAC #1 FIRE ALARM cd CANDELA N2 NAC #2 PROJECT DETAILS D DETECTOR NAC NOTIFICATION APR-IANCE CIRCUIT EC ELECTRICAL CONTRACTOR NEC NATIONAL ELECTRICAL CODE EOL END OFLINE NFPA NATIONAL FIRE PROTECTION ASSOCIATION FAA FACP FI RE ALARM AN N U N C IATO R A RE ALARM CO N TRO L PAN EL nts ROR NOT TO SCALE RATEOFRISE SHEET NUMBER H/S HORN / STROBE S_C SIGNAL LINE CIRCUIT IBC INTERNATIONAL BUILDING CODE STG STORAGE IFC INTERNATIONAL FIRECODE WP WEATHERPROOF FA OmO L1 S_C LOOP PANEL FACP (GWF-7075) BATTERY CALCULATION (SECONDARY POWER SOURCE REQUIREMENTS) STANDBY CURRENT (AMPS) SECONDARY ALARM CURRENT (AMPS) PANEL COMPONENTS QTY PART NO. DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL 1 GWF-7075 Main Board Intelligent Fire Alarm Control Panel Main Board 0 0 0 0 CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT DRAW (A) TOTAL (A) CURRENT DRAW (A) TOTAL (A) FACP•ANN F^^ 1 RA-1000 Remote annunciator for use with GWF-7075 0.03 0.03 0.065 0.065 OP 20 ASD-PI3 / B300-6 BASE Addressable, Photo, Det. 0.0003 0.006 0.0003 0.006 FACP•L1 0 4 ATD-L3R / B300-6 BASE ADDRESSABLE 1357 ROR HEAT DETECTOR 0.0003 0.0012 0.0003 0.0012 0 1 MS-7ASF Addressable Pull Station 0.0003 0.0003 0.007 0.007 ®4 WID 1 P2RK Horn/Strobe,WP,Wall, 30cd 0 0 0.116 0.116 O" 3 PC2WL Horn/Strobe, Ceiling, 15cd 0 0 0.071 0.213 FACP•N1 1 PC2WL Horn/Strobe, Ceiling, 30cd 0 0 0.09 0.09 1 PC2WL Horn/Strobe, Ceiling,75cd 0 0 0.143 0.143 xi 1 SCWL Strobe, Ceiling, 15cd 0 0 0.041 0.041 ®4 WID 1 P2RK Horn/Strobe,WP,Wall , 110cd 0 0 0.221 0.221 4 PC2WL Horn/Strobe, Ceiling, 15cd 0 0 0.071 0.284 FACP•N2 2 PC2WL Horn/Strobe, Ceiling, 30cd 0 0 0.09 0.18 1 PC2WL Horn/Strobe, Ceiling, 75cd 0 0 0.143 0.143 x< 1 5 1 SCWL Strobe, Ceiling, 15cd 0 1 0 1 0.041 1 0.205 TOTAL STANDBY (A) 1 0.0375 1 TOTAL ALARM (A) 1 1.7152 REQUIRED STANDBY TIME = 24 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD (A) 0.0375 24 1 0.9 SECONDARY ALARM LOAD (A) 1.7152 0.08 1 0.14 STANDBY AND ALARM SUBTOTAL (AMP HOURS) 1.04 DERATING FACTOR 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS) 1.25 PROVIDE (2) 12V 7AH BATTERIES CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 0.28 FACP N1 POINT-TO-POINT REPORT Min. Operational Voltage: 16 End Of Line Voltage: 20.12 Max. Circuit Current (A): 2.5 Voltage Drop Percent: 1.38 % Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 0.603 Circuit Wiring Properties: 'A' 994 14 AWG, 4 Cond. Solid Copper FPLR Analog Unshielded Total Circuit Length (Ft): 129 Spare Current (A): 1.897 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (0): 0.793052 Spare Current (A) Percent: 75.88 % Device Label Part No. Description Device Current Remaining Dist. From Resistance From Voltage Drop From Voltage At Device Total Voltage Drop Voltage Drop Percent (A) Current (A) Previous (Ft) Previous (0) Previous Nl-001 SCWL Strobe, Ceiling, White 15cd 0.041 0.603 7 0.045751 0.03 20.37 0.03 0.14 % Nl-002 PC2WL Horn/Strobe, Ceiling, 0.071 0.562 22 0.132709 0.07 20.3 0.1 0.50 % White 15cd Nl-003 PC2WL Horn/Strobe, Ceiling, 0.143 0.491 18 0.109087 0.05 20.24 0.16 0.76 % White 75cd Nl-004 P2RK Horn/Strobe,WP,Wall , 0.116 0.348 40 0.246455 0.09 20.16 0.24 1.18 % Red 30cd Nl-005 PC2WL Horn/Strobe, Ceiling, 0.071 0.232 11 0.069696 0.02 20.14 0.26 1.26 % White 15cd Nl-006 PC2WL Horn/Strobe, Ceiling, 0.071 0.161 16 0.096179 0.02 20.13 0.27 1.34 % White 15cd N1.007 EOL PC2WL Horn/Strobe, Ceiling, 0.09 0.09 15 0.093175 0.01 20.12 0.28 1.38 % White 30cd Calculation Methods: Resistance From Previous (0) = Wire Resistance (D/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) CIRCUIT SETTINGS TOTALS Starting Calculation Voltage: 20.4 Max. Voltage Drop: 0.72 FACP N2 POINT-TO-POINT REPORT Min. Operational Voltage: 16 End Of Line Voltage: 19.68 Max. Circuit Current (A): 2.5 Voltage Drop Percent: 3.55 % Wire Resistance (0/kFt): 3.07 Total Circuit Current (A): 1.033 Circuit Wiring Properties: 'A' 994 14 AWG, 4 Cond. Solid Copper FPLR Analog Unshielded Total Circuit Length (Ft): 211 Spare Current (A): 1.467 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (f2): 1.292853 Spare Current (A) Percent: 58.68 % Device Label Part No. Description Device Current Remaining Dist. From Resistance From Voltage Drop From Voltage At Device Total Voltage Drop Voltage Drop Percent (A) Current (A) Previous (Ft) Previous (0) Previous N2.001 PC2WL Horn/Strobe, Ceiling, 0.071 1.033 30 0.1842 0.19 20.21 0.19 0.93 % White 15cd N2.002 SCWL Strobe, Ceiling, White 0.041 0.962 12 0.075828 0.07 20.14 0.26 1.29 % 15cd Horn/Strobe, Ceiling, N2.003 PC2WL White 75cd 0.143 0.921 13 0.082137 0.08 20.06 0.34 1.66 % Strobe, Ceiling, White N2.004 SCWL 15cd 0.041 0.778 23 0.141139 0.11 19.95 0.45 2.20 % N2.005 PC2WL Horn/Strobe, Ceiling, 0.071 0.737 9 0.056303 0.04 19.91 0.49 2.40 % White 15cd N2.006 SCWL Strobe, Ceiling, White 0.041 0.666 9 0.05526 0.04 19.87 0.53 2.58 % 15cd N2.007 P2RK Horn/Strobe,WP,Wall , 0.221 0.625 8 0.047984 0.03 19.84 0.56 2.73 % Red 110cd N2.008 PC2WL Horn/Strobe, Ceiling, 0.09 0.404 31 0.188358 0.08 19.77 0.63 3.10 % White 30cd N2.009 PC2WL Horn/Strobe, Ceiling, 0.071 0.314 24 0.145104 0.05 19.72 0.68 3.33 % White 15cd Strobe, Ceiling, White N2.010 SCWL 15cd 0.041 0.243 4 0.023411 0.01 19.72 0.68 3.35 % N2.011 PC2WL Horn/Strobe, Ceiling, 0.071 0.202 11 0.068704 0.01 19.7 0.7 o 3.42 /o White 15cd N2.012 SCWL Strobe, Ceiling, White 0.041 0.131 20 0.125623 0.02 19.69 0.71 3.50 % 15cd N2.013 EOL PC2WL Horn/Strobe, Ceiling, 0.09 0.09 16 0.098802 0.01 19.68 0.72 3.55 % White 30cd Calculation Methods: Resistance From Previous (0) = Wire Resistance (f)/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (0) x Remaining Current (A) BATTERY & VOLTAGE DROP CALCULATIONS N2.007 N2.013 EOL N2.012 N2.011 N2.010 N2.009 N2.008 110cd N2.006 N2.005 N2.004 N2.003 N2.002 N2.001 30cd 15cd , _ ,15cd 15cd , _ ,15cd _ , 30cd WP 15cd , _ ,15cd 15cd , _ , 75cd 15cd , _ ,15cd L1•DO13 L1•DO14 L1•DO15 L1•DO16 L1•DO17 L1•DO18 L1•DO19 L1•D020 L1•D021 L1•D022 L1•D023 L1•D024 SECOND FLOOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - INSTALLATION KEYNOTES O A DEDICATED 120VAC POWER CIRCUITS IS REQUIRED FOR THE FACP AND AES RADIO. COORDINATE CONNECTIONS OF DEDICATED POWER WITH THE E.C. O OUTDOOR HORN/STROBE TO BE INSTALLED IN A LOCATION THAT IS SERVICEABLE AND CLEARLY VISIBLE FOR APPROACHING EMERGENCY VEHICLES. 3a) ADDITIONAL OUTDOOR HORN/STROBE PROVIDED FOR PLAYGROUND AREA OCCUPANT NOTIFICATION. CABLE - WIRE LEGEND LINE TYPE LABEL CABLE TYPE AWG RESIST. (- /Kft) DESCRIPTION A 14/2 FPLR 14 3.07 NAC : NOTIFICATION APPLIANCE CIRCUIT D 18/4 FPLR 18 7.77 SBUS : ANNUNCIATOR U 18/2 FPLR 18 7.77 SLC : SIGNALING LINE CIRCUIT FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM VSOTEC; w NFPA CFPS #14T3 (AA QB QC QD QE a W > _ _ _ _- W I w zv � 00 CO) CO H Cn EMPLOYEE o C LUNCH RM KI CHEN ®® 2 c9 ®® !2a N � >- OFFICEW a L1•DO18 1 J-00,-&� Ho�� w � w 75cd _ _ _ - o W * O cd 2A Z�w JUG �: w 1A L1•D021 ' ' s L1•D017 a W 5Q- O s 1 U N2.002 0 z W wui -j a o N2.010 H' N2.009 s 1•D020 15cd REVISION RECORD 15 15cd U 2A N21O s UI-FICE DATE / DESCRIPTION �`�� •D021 N 001 1A:DN TO THEACP s 1A L1•D01 L1•D016 15cd ATTi� L1•D U s s H ACES H L1•D01 s s L1•DO13 1U:DN TO THE FACP HI mad N2.008 1A N2.013 EOL ' 30cd N2.004 2A FFICE 30cd 1U N2.005 - - - - - - - H 15cd OFFICE OFFI E D015 i 135° I F-N2.006 2A N2.007_ _ 110cd WP I I I SECOND FLOOR PLAN SCALE: 1 /8" = 1' I I I I ' N' •004 WT (1 MAN (1) AN FFICE OFF, ICE 1• I 1 1A •DO 2 �1 s L1•DO09 s N 1.006 H s 15cd L1•DO10 1U OFFICE L1•D011 s j I H Nl-007 EOL ST 30cd ' RECEPTION I N 1.004 ED OAT® Ca�U,T FAA N1.007 EOL Nl-006 Nl-005 30cd Nl-003 Nl-002 Nl-001 30cd 15cd 15cd WP 75cd 15cd 15cd L1•M001 L1•D001 L1•D002 L1•D003 L1•D004 L1•D005 L1•D006 L1•D007 L1•D008 L1•D009 L1•D010 L1•D011 L1•DO12 H H H H FACP ' 5 -� oii u I FIRST -----------------------------------------------------------------------FLOOR nEEICE (1) MA 1U s L1•D001 BREA ROOM OFFICE i O 1A 001 F Doc - I IV L1•DO03 FACP AEs 1A _ - •D007 1D 35° N1.01 i ' 15cd 1 U A 002 H L1•D0041 !N1-002 i d II I - - I 1A: UP TO 2ND FLOOR 12 J-OUTLINEOF Nl-003CLOSET \4E� ABOVE L1•D005 75cd s s L1•D006 I 9 I - - JREA - i i BEAM RECEIVED Sep 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DATE: 1 09.01.23 PROJECT NAME W LU - LU V cc W CN O V 00 Q Q O C I*- 0 O Z r O r Q N Q LL W Q O Z SHEET TITLE FIRE ALARM INSTALLATION SINGLE LINE RISER DIAGRAM FIRST FLOOR PLAN SCALE: 1 /8" = 1' SHEET NUMBER I FA 1m0