REV1 APPROVED BLD2022-1670+Architectural_Plan+8.8.2023_4.54.29_PM+3714549LOT COVERAGE SUMMARY OWNER: Jenni and David Morts PROJECT ADDRESS: 1034 B Avenue S Edmonds, Washington 98020 SNOHOMISH PARCEL NUMBER: 00619400400301 LOT AREA: .17 Acres LEGAL: THE SOUTH 1/2 OF LOT 39 BLOCK 004 YOSTS 1ST ADDITION QUARTER SECTION T&R NW 25 T27N R 3E Latitude 47.81, Longitude-122.38 PROPERTY USE 111 Single Family Residence GENERAL NOTES & SPECIFICATIONS BUILDING AREA SUMMARY BUILDING HEIGHT SUMMARY Main Floor Finished Area = 1702 sq ft Lower Floor Finished Area = 754 sq ft From Survey on Next Page - Garage = 806 sq ft 4-corners of rectangle = New Main Finished Area = 107 sq ft 206.95+213.4+215.7+208.1 = 844.151/4 = 211.04' Total Main Floor Finished area = 1702 +107 = 1809 sq ft Maximum Allowable Height = 25' above average grade = 211.04'+25'= 236.04' New Exterior Deck = 524 sq ft Actual III 'eight � 232.2' per Sunmy- (shown on elevations) Nothing in the permit approval process shall be Proposed Height interpreted as allowing or permitting the maintenance = 233.9' of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless APPROVED BY PLANNING of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate n enforcement action. Aug 10 2023 1. ALL WORK SHALL COMPLY WITH APPLICABLE CODES, ORDINANCES, AND LAWS. 2. NOTED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AT ALL TIMES. 3. EXTERIOR WALL DIMENSIONS ARE TO FACE OF CONCRETE AND/OR FACE OF STUD UNLESS OTHERWISE NOTED. 4. ALL CONDUIT AND PIPING SHALL BE CONCEALED. ANY EXPOSED WORK SHALL BE VERIFIED WITH THE ARCHITECT. 5. IN CASE OF ANY CONFLICT WHEREIN THE METHODS OR STANDARDS OF INSTALLATION OR THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ALL CONFLICTS. 6. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION WITH OTHER CONTRACTORS TO SECURE COMPLIANCE OF DRAWINGS AND SPECIFICATIONS, THE ACCURATE LOCATION OF STRUCTURAL MEMBERS AND OPENINGS FOR MECHANICAL, ELECTRICAL, STAIRS, AND MISCELLANEOUS EQUIPMENT. 7. ALL EXTERIOR OPENINGS, FLASHINGS, COUNTERFLASHING, EXPANSION JOINTS AND THE LIKE SHALL BE CONSTRUCTED IN SUCH A MANNER AS TO MAKE THEM WEATHERPROOF. 8. VERIFY ALL VARIATIONS OR DISCREPANCIES WITH THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK IN QUESTION. 9. SERVICE WATER PIPES IN UNHEATED SPACES SHALL BE INSULATED PER WASHINGTON STATE ENERGY CODE. 10. METAL DUCTS JOINTS SHALL BE TAPED AND INSULATED. 11. OPENINGS TO BE CAULKED, SEALED, OR WEATHER-STRIPPED. 12. BATT INSULATION TEARS AND/OR JOINTS SHALL BE SEALED WITH TAPE.. 13. SHOWERS: FLOW CONTROL LIMITED PER WASHINGTON STATE ENERGY CODE. 14. MOISTURE CONTROL TO BE PROVIDED PER WASHINGTON STATE ENERGY CODE. 15. GROUND COVER WITHIN CRAWL SPACE: COVER WITH MINIMUM 6 MIL (0.006") BLACK POLYETHYLENE OR EQUIVALENT, LAPPED 12" AT EACH JOINT AND EXTENDED TO FOUNDATION WALLS, PER WASHINGTON STATE ENERGY CODE. or 10M YWD- Lot Area =7405 sq ft Allowable lot coverage = 35% Drawing Index TS-1.0 SITE PLAN/TITLE SHEET =.35*7513 = 2630 sq ft Existing House = 1890 sq ft Existing Exterior Deck/Stairs = 96.5' sq ft New Exterior Deck = 525 sq ft Total proposed Lot Coverage = 2512 sq ft < Allow 2630 sq ft Therefore Zone RS-6 O.K. Corner Flag Setbacks: Required Actual North 5' 51611 East 20' 42' 9" South 5' 41611 15' 34' West 25' 22' 11" Height 02M Site Plan. 1 If = 1 01-OIV SUR-1.0 SURVEY A-1.0 EXISTING MAIN AND LOWER FLOOR PLANS A-2.0 PROPOSED FLOOR PLANS A-3.0 PROPOSED BUIDING ELEVATIONS A-4.0 PROPOSED SECTIONS/WINDOW/DOOR SCHEDULE A-5.0 ENERGY SHEET S-1.0 STRUCTURAL NOTES S-2.0 MAIN FLOOR FRAMING/LOWER FLOOR FOUNDATION/LOWER FLOOR SHEAR WALL PLANS S-3.0 MAIN FLOOR SHEAR WALL/ ROOF FRAMING REVISIONS fil'UCTURAL DETAILS S-5.0 STRUCTURAL D AI 0 5 10 20 GRAPHIC SCALE M M w z w 072 /V PHEN T. TAPP OF WASOGTON RESUB Aug 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT revisions 12/1 /22 12/8/22 1 /19/23 1 /23/23 2/8/23 7/7/23 7/31 /23 8/8/23 O Q Q O °° ■� �■d p ■ � Im = fn W N W V m C O ""0 CDw CL CL M w C co _O U-5 C o o .� U co M C' 6 s ON N N �� ��w� U o_ o cn L co (V Cn This work was prepared by me or under my supervision. Sheet Contents: REVISION Aug 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Scale: as noted Date: 11 /19/22 Job no.: T22J6 Drawn by: STT Sheet no.: TS-1.0 of 12 LEGAL DESCRIPTION GRAPHIC & BOUNDARY SURVEY PER STATUTORY WARRANTY DEED RECORDING #202108160286 LOT 3 ON BLOCK 4 OF THE PLAT OF YOST'S FIRST ADDITION TO EDMONDS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 8 OF PLATS, PAGE 6, RECORDS OF SNOHOMISH COUNTY, i WASHINGTON; FOUND MON IN CASE i IRON PIPE, DOWN 1.2' EXCEPT THE NORTH 60 FEET THEREOF. (5.56'W & 6.66'S OF CALC'D INTX) SITUATED IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. FOUND MON IN CASE BRASS DISK, DOWN 0.4' BASI OF BEARINGS (& 2.46'W ►.� OFF CCAALC'D INTX) <9 SSMH N 88'45'07" W 329.77' CALC'D (329.93' R1 & R2) FOUND MON IN CASE NAD 83(2011) WASHINGTON NORTH STATE PLANE COORDINATES PER GPS OBSERVATIONS dQ9 RIM=195.94' It It� � -, BRASS DISK, DOWN 0.2' � ►�� `5aq, ,9. �O•. , `��ti IE(W) 8"GONG=189.07' IE(S) 8"CONC=191.34' PINE ST REFERENCES 0 �° �o .. �- SS SS IE(E) 8"CONC=189,56' SS SS SS CB (TYPE 1) SS SS s� ss ss ss - SS - SS SS SS -p - SS SS S R1. RECORD OF SURVEY, AUDITOR'S FILE N0. 9006065002, RIM-200.97' g� ssMH RECORDS OF SNOHOMISH COUNTY, WASHINGTON. IE(W) 8"CPP=199.32' RIM=214.63' R2. SHORT SUBDIVISION, AUDITOR'S FILE NO. 202103305005, N� (IS IE(S) 8"PVC=199.37 IE(W) 8"CONC=208.85' IE(S) 8"CONC=209.32' RECORDS OF SNOHOMISH COUNTY, WASHINGTON. IE(E) 8"CONC=209.67' W VERTICAL DA UM U NAVD 88 PER GPS OBSERVATIONS N SITE TEMP. BENCHMARK o DESCRIPTION: SET PK NAIL W/ RED WASHER LOCATION: SET IN CONC. WALK E OF E PROP LINE n ELEVATION: 221.87' I> w o I CB (TYPE 1) RIM=221.03' SURVEYOR'S NOTE IE(W/E) 12"GONGcn w / 1. THE TOPOGRAPHIC SURVEY SHOWN HEREON WAS PERFORMED IN o ( CB (TYPE 1) � AUGUST OF 2022. THE FIELD DATA WAS COLLECTED AND N o° Sp RIM=222.62' RECORDED ON MAGNETIC MEDIA THROUGH AN ELECTRONIC IE(N) 4"CONC=219.77' (n THEODOLITE. THE DATA FILE IS ARCHIVED ON DISC OR CD. N o FENCE COR STEPS 1.4'N STEPS 1.3'N SOS IE(W) 8"CONC=219.72' w WRITTEN FIELD NOTES MAY NOT EXIST. CONTOURS ARE SHOWN °" o.3'N of OF PROP LINE OF PROP LINE c IE(SE) 4"CONC=220.02' U FOR CONVENIENCE ONLY. DESIGN SHOULD RELY ON SPOT PROP LINE I2 _ IE(E) 4"PVC=221.47' •- O N ELEVATIONS. o� oti o1 ° ti o (n e FENCE COR 20 3.3'S OF N 8 `44'48" W M _EA ° _ _ ASPH. 14.7' Y z 8 0 �� o� �titi e m a. SD Q o 0 Z W (� O 0) 2. ALL MONUMENTS SHOWN HEREON WERE LOCATED DURING THE oti `� ° so PROP LINE ti°6a 24 87 co o ti RAILROAD TIE �o 6 ti �o� tip° `� I' Z o COURSE OF THIS SURVEY UNLESS OTHERWISE NOTED. °� N ° 9 p9 ch m o ml DC CONC 0.7'S •� ". ° • • W .D STAIRS a • ,�9_ ° ly FENCE COR 0.3'N k. � °. tia° c�� n 0 3. THE TYPES AND LOCATIONS OF ANY UTILITIES SHOWN ON THIS °6°` ° �o AT CQ�1C; ,' ,h CONC 0.7'S n �^ SAVE v`° RAILROAD TIE o BLOC WALL ",�j Q 0 w DRAWING ARE BASED ON INFORMATION PROVIDED TO US, BY cn N FOUND EBAR/CAP ° ° ' e ., °• ° ° o - - ' RO STEPS ti10 o m m p OTHERS OR GENERAL INFORMATION READILY AVAILABLE IN THE LS# 4 151 ob FOUN EBAR/CAP k(, , PUBLIC DOMAIN INCLUDING, AS APPLICABLE, IDENTIFYING o 0.10'S FROM PROP COR ., EA LS# 45151 ti° N J W 0 O MARKINGS PLACED BY UTILITY LOCATE SERVICES AND OBSERVED N 42.5' °• • o o5'S OF LINE & 'E ', w (� w BY TERRANE IN THE FIELD. AS SUCH, THE UTILITY INFORMATION " '• •' w 6",(2)4"CE > 0, FROM PROP COR , 30' ,', �, p SHOWN ON THESE DRAWINGS ARE FOR INFORMATIONAL N N �• •° %, .•, w 7"cED ROW � � � Q LLl PURPOSES ONLY AND SHOULD NOT BE RELIED ON FOR DESIGN °k . BLDG ° °0 I 4"MAP °: No I "P Q OR CONSTRUCTION PURPOSES; TERRANE IS NOT RESPONSIBLE OR °�41 C, OVERHANG ;° "•' �h O LIABLE FOR THE ACCURACY OR COMPLETENESS OF THIS UTILITY o�.° CONt-�0 I ��Wtiti° io 0 INFORMATION. FOR THE ACCURATE LOCATION AND TYPE OF ° °� .I ;PATIO �� Q P�oOfk k °� ,�4 • 0 UTILITIES NECESSARY FOR DESIGN AND CONSTRUCTION, PLEASE •,° �0� F� tit°� 7",6 CED •' ..: � CONTACT THE SITE OWNER AND THE LOCAL UTILITY LOCATE Of p • $ O�° 0 o SERVICE (800-424-5555). n c° 6»DEC I o°®� GJ�� G'� Z;ho • ° . „• ° •• °• Z 0 • •• •• 4. SUBJECT PROPERTY TAX PARCEL NO. 00619400400301 J z LL! a o 11 ,r, A CONC••' �`° o - Q 5. SUBJECT PROPERTY AREA PER THIS SURVEY IS 7,512 S.F. r, _ 00 ° ° ^� ° ° Ai�E a O ° • I .• PATIO °, �1 ,\ •EPVE •. & LUM :. °, . ° •° • F- (0.17 ACRES) C a_ w > M ° • , ' °, .. z e ° G E• '1 �• *r--a,o:- T FFF , eh •� ° J w Q W 3 6. THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE cV ^ I.V �0- `t n •°• °• • ` ° p • "° • '° .• °•.I • �• �� ° &< ,e RI�M�2Y7.62°• ^° •, •° '° "� °'" LLJ •" SITE M cwn> m Q Q N REPORT. EASEMENTS AND OTHER ENCUMBRANCES MAY EXIST o �° ' I O .' •a • °.• • •° ^• °j e •° HOUSE NO. 1034 .� FOOTPRINT-1,600 SF .,° �' 4 '• e� ti' ',° ELEV=:t21.87' m m Np N THAT ARE NOT SHOWN HEREON. z .° a , �. • • ° e I• �o. �� .��9• ��. • �A• L 7. EXISTING STRUCTURES) LOCATION AND DIMENSIONS ARE 2 ❑ v , •' •• ° .�. '. •• e' .•° colvc,' �° ••°• a I ., ^; CONC •�I °� o titi� ,a�• °� w a MEASURED FROM THE FACE OF THE SIDING UNLESS OTHERWISE t� TEL SENTRY a • ' DRgVEWAY• ,°• ••" • ��. STEP z NOTED. "° °" . ° •' •' •• .. ° '• ° ;° "• " '•� L '' I �� • ° , 1� `� ti o �� c, gw tiz 8. FIELD DATA FOR THIS SURVEY WAS OBTAINED BY DIRECT FIELD °.' .9 °•" . ; -A. °`�� w Iw M •, `l' MEASUREMENTS WITH A CALIBRATED ELECTRONIC 5-SECOND cO cn "• ,•° '. •° •• '° '' °; : I,• • W •p p�� TOTAL STATION AND/OR SURVEY GRADE GPS OBSERVATIONS. w cn a• • • • • ��o A. • • • °� "FIR W W W ALL ANGULAR AND LINEAR RELATIONSHIPS ARE ACCURATE AND ••°4, ° • °�"°� ti°k I °° . MEET THE STANDARDS SET BY WAC 332-130-090. ° APPROX. LOCATION a SET ° - - �. 1§ • EAVE ti PER RECORDS (TYP) •.6 LE REBAR/CAP you ° g"FI - o EGEND Z - Lo ti°b �h 42.9' �x : U, 200 cD 0 6"DEC °, L+J AREA DRAIN (-)SEWER MANHOLE ° - ti I I 0 ASPHALT SURFACE SD STORM DRAIN LINE BENCHMARK TEL SENTRY ❑ TELEPHONE SENTRY ° �� ti h N 8'44'38' 24.87' (125.00' PLAT) l ti N 88'44' 8" W 30.00' FOUND IRON PIPE ® BRICK SURFACE SIZE TYPE O TREE (AS NOTED) BUILDING W WATER LINE m N FENCE COR 1.2'S OF w 0 cn FENCE COR AP X. ON PER i° 0.20'S OF LINE & 3 (5) J_ CENTERLINE ROW r, WM C WATER METER PROP LINE o PROP LINE MAP NO. 0.39'W FROM PROP COR " coo 2Qn �� ti M CLEANOUT WV WATER VALVE m ALL Y o CONCRETE SURFACE BLDG BUILDING ® DECK C.C. CENTER CHANNEL -EJ o U) o°� THE CLOSEST BUILDING CORNER TO r- �-- X X FENCE LINE (CHAIN LINK) CALC'D CALCULATED THE RIGHT-OF-WAY �- FENCE LINE (WOOD) CB CATCH BASIN a N rn FOR THIS ISPROPERTY G GAS LINE COS CITY OF SEATTLE 20 CONC CONCRETE GUY ANCHOR SD c aJ INLET (TYPE 1) COR CORNER DEC DECIDUOUS o CB (TYPE 1) LUM LUMINAIRE ELEV ELEVATION ® MAILBOX (RESIDENTIAL) o N to RIM=204.83' IE(N) 8"PVC=203.18' (V v o - EVG EVERGREEN 4- ►fit MONUMENT (IN CASE, FOUND) FF FINISH FLOOR IE(E) 4"PVC=203.63' P ❑ POWER METER G GAS IE(S) 8"GONG=203.18' P POWER (OVERHEAD) LS# LAND SURVEYOR NUMBER o rn PP O POWER POLE MEAS MEASURED N v O - PROPERTY LINE (SUBJECT) M MONUMENT OHP OVERHEAD POWER SSG° REVISION v o0 00 00 V) � REBAR &CAP (SET) Q 0 REBAR AS NOTED (FOUND) PROP PROPERTY ROS RECORD OF SURVEY ^ SSMH RIM=206.40' Aug 09 2023 00 Ln RETAINING WALL SD SERVICE DRAIN � ( IE(N/S) 8"GONG CITY OFEDMONDS c > > 1- � RIGHT-OF-WAY LINES SSMH SANITARY SEWER MANHOLE ���' =200.13'(C.C.) DEVELOPMENT SERVICES DEPARTMENT ROCKERY SF SQUARE FEET N O � Q SS SEWER LINE HX HEAT EXCHANGER �(3 ��p'` �959�9. CD m VICINITY MAP °SS�1 N.T.S. FOUND MON IN CASE FIR ST �'� �� S RESUB JOB NUMBER: 221319 DATE: 08/18/22 Pine St Aug 2023 V TACK/LEAD, DOWN 0.9' N 88'44'19" W 329.773' MEAS. (329.79 R1 & R2) F E CITY OF EDMONDS DRAFTED BY. TDB D S D < n < FOUND MON IN CASE DEVELOPMENT SERVICES DEPARTMENT CHECKED BY: KOP/CSP Pine Street Playfield rn W Q BRASS DISK, DOWN 0.4' SCALE: ill = 10' Hk En REVISION HISTORY > "e-ipo' ncare and Waxing P" STEEP SLOPE/BUFFER DISCLAIMER: THE LOCATION AND EXTENT of STEEP SLOPES SHOWN ON THIS DRAWING ARE FOR INDEXING INFORMATION INFORMATIONAL PURPOSES ONLY AND CANNOT BE RELIED ON FOR DESIGN AND/OR SE 1/4 NW 1/4 CONSTRUCTION. THE PITCH, LOCATION, AND EXTENT ARE BASED SOLELY ON OUR 4 4 GENERAL OBSERVATIONS ON SITE AND OUR CURSORY REVIEW OF READILY AVAILABLE SITE NW NE SECTION: 25 10 0 5 10 PUBLIC DOCUMENTS; AS SUCH, TERRANE CANNOT BE LIABLE OR RESPONSIBLE FOR D Fir St > Fir St THE ACCURACY OR COMPLETENESS OF ANY STEEP SLOPE INFORMATION. ULTIMATELY, TOWNSHIP: 27N THE LIMITS AND EXTENT OF ANY STEEP SLOPES ASSOCIATED WITH ANY SETBACKS OR SHEET NUMBER °' D SW 4 SE 4 RANGE: 03E, W.M. ( IN FEET) OTHER DESIGN OR CONSTRUCTION PARAMETERS MUST BE DISCUSSED AND APPROVED BY THE REVIEWING AGENCY BEFORE ANY CONSTRUCTION CAN OCCUR. 1 OF 1 D COUNTY: SNOHOMISH 1 INCH = 10 FT. Existing Lower Floor Plan 1/4" = 1'-0" ,-----------------------�, I� /I LIVING AREA 1554 50 FT Existing Main Floor Plan with Roof Outline 1 /4" = 1'-0" ISION )9 2023 EDMONDS ENT SERVICES RTMENT r 5� I �STERE� i I C;HITE I, RHE:AS' ± TTAPP 1E OFWNCTnKj revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 7/31 /23 8/8/23 O E OC .M � o o O °° ._ ♦a 0 OC W zM Q�° W� i�> t� m O ° 0 0 rW M w M _O Lfi C � U co M C, 6 U a O cn L co (V Cn This work was prepared by me or under my supervision. Sheet Contents: RESUB Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Scale: as noted Date: 11 /9/22 Job no.: T22J6 Drawn by: STT Sheet no.: A-1.0 of 12 N Ln T_ 219" 166" 604" Existing Lower Floor Plan --(NO CHANGE) 1/4" = 1'-0" Wall Sc:hp.d0P EXISTING WALL TO REMAIN _I EXISTING WALL TO BE REMOVED NEW WALL r 42-0 1 /2" Proposed Main Floor Plan 1 /4" = V-0" ENERGY CODE SUMMARY (NEW C nNSTRUCTION) ANALYSIS IS BASED ON :2018 WASHINGTON STATE ENERGY CODE, RESIDENTIAL PROVISIONS, CHAPTERS 1 THRU 5 FOR RESIDENTIAL OCCUPANCY: (TABLE R301.1, CLIMATE ZONE 4C, AND TABLE R402.1.1 - HEATING BY OTHER FUELS). PERCENTAGE OF GLAZING TO TOTAL FLOOR AREA: UNLIMITED MAXIMUM GLAZING U-VALUE: (VERTICAL) MAXIMUM GLAZING U-VALUE: (OVERHEAD) MAXIMUM DOOR U-VALUE: TABLE R303.1.3(1) MINIMUM REQUIRED INSULATION VALUES CEILINGS: CEILINGS: (VAULTED -SINGLE RAFTER) WALLS ABOVE GRADE: REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Erie Coe�' BUILDING OFFICIAL Aug 10 2023 APPROVED DATE m m —UP— REVISION revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 7/31 /23 8/8/23 01 a r o 0 00 a) ■ �■■r C Lu Q w� N V ca 0 0 �oC)W M W C M O o o 6 N L U M M C' 6 a) U a o cn L M N Cn This work was prepared by me or under my supervision. Sheet Contents: RESUB Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Scale: as noted Date: 11 /9/22 Job no.: T22J6 Drawn by: STT Sheet no.: A-2.0 of 12 �u v ALL NEW CONSTRUCTION ■ N ■ ■ ■ SEE RAILING DETA� ■ 1/S-2.0 � I ■ ■ ■ ■ _______________ W _______________________________ steel •� 6x6 post post beyond f Maximum Roof Height (see calcs TP-1) - — - — - -236.04' ---1-- ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■.....Proposed Roof Height 233.9' ■ ■ ■ ■ U) N ■ ■ ■ ■ ■ ■ ■ Ex. Main FI'r 218.4' -T fo tngs Proposed South Elevation 1 /4" = 1'-0" ALL NEW CONSTRUCTIONI Average Grade 211.9' Maximum Roof Height (see calcs TP-1) 236.04' ---------------- TALL NEW CONSTRUCTION ■ l6w � ■ II I � . ■ ■ ■ ■ ■ ■ ■ ■ ■ . k N ■ ■ ■ ■ ■ ■ 42" ■ i ■ ■ ■ ■ ■ ■ IS ■ ■ ■ ■ ■ ■ ■ ■ IS ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ IS ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 7 I�I�i I �I� 1 � ii�ii�■ 1-42In Proposed West Elevation 1 /4" = 1'-0" ALL NEW CONSTRUCTIONJ\ ■ Proposed Roof Height ■ ■ ■ ....... - - 233.9' ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Ex.Main FIT ■ ---------------------------------------------------- - basement beyond Average Grade 211.9' Proposed East Elevation 1 /4" = 1'-0" Proposed North Elevation 1 /4" = 1'-0" REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 7/31 /23 8/8/23 0 AE W �+ o N 0 ■— �+ o W� cn Qz Z � W � V m C r W Uj C M _O Lfi C S \ O O .S; U M Cz Cz s Cz� U a O cn L M N Cn This work was prepared by me or under my supervision. Sheet Contents: RESUB Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Scale: as noted Date: 11 /9/22 Job no.: T22J6 Drawn by: STT Sheet no.: A-3.0 of 12 ALL NEW CONSTRUCTION revisions 7/31 /23 Basement N i n d ows - replacement windows (not part of remodel) WINDOW SCHEDULE NUMBER I COMMENTS QTY FLOOR RIO MANUFACTURER WIDTH HEIGHT DESCRIPTION HERDER U-FACTOR HEADER HEIGHT EGRE55 W04 BASEMENT GUEST BATH 3 1 0 35"X41" MILGARD 34" 40" LEFT SLIDING 2"X6"X38" (2) 0.3 85 112" W05 BASEMENT GUEST BED 4 1 0 34 718"X41" MILGARD 33 718" 40" SINGLE CASEMENT-HL 2"Xb"X37 we (2) 0.28 85 112" YES W06 BASEMENT GUEST BED 3 1 0 34 718"X41" MILGARD 133 718" 40" 1 SINGLE CASEMENT-HR 2"X6"X37 718" 2 0.28 185 112" YES W16 BASEMENT LIVING RM 1 0 11"X47" MILGARD 70" 46" ILEFT 5LIDIN6 2"XS"X74" 2 0.28 1.55 112" YES W18 GARAGE 1 0 73"X41" MILGARD 7211 40's ILEFT SLIDING 2"X101lX76" 2 0.28 87 112" YES 1st Floor Nindows 000o i� WINDOW SCHEDULE - 15T FLOOR Doors NUMBER COMMENTS (LOCATION) QTY FLOOR RIO MANUFACTURER WIDTH HEIGHT DESCRIPTION HEADER HERDER HEIGHT BOTTOM U-FACTOR EGRE55 NO SUNRDOM TRANSOMS W. PAGING 3 1 57 13116"X22 112" MILGARD 56 13/16" 21 112" FIXED GLASS 2"XS"X60 13116" (2) 114 112" 92 112" 0.28 W02 SUNRDOM TRANSOMS 5. PAGING 2 1 42 314"X22 112" MILGARD 41 314" 21 112" FIXED GLASS 2"X6"X45 314" (2) 114 112" q2 112" 0.28 W03 SUNRDOM TRANSOMS N. PAGING 2 1 42 114"X22 112" MILGARD 41 114" 21 112" FIXED GLASS 2"X6"X45 114" 2 114 112" q2 112" 0.2$ W04 SUNRDOM SLIDING ODOR 5. PAGING 1 1 86"X80" MILGARD 85 112" 79 112 EXT. SLIDER -GLASS PANEL 2��X10��XS9boll" 2 80 0 0.28 YES W05 SUNRDOM 3-PANEL W. PAGING 1 1 17b X71" MRRVIN 174 112" 70 114 FIXED GLASS 2 X12 X17q ,(2 80 3181 q 314 1 0.28 WOb SUNROOM 1-PANEL N. PAGING 1 1 86"X71" MARVIN 84 112" 70 114" FIXED GLASS 2"X10"X89" (2) 80 318" 9 314" 0.27 W07 PRIMARY BEDROOM CLOSET -STAINED GLASS 1 1 62 71S"X26 71S" NA 5q 318" 23 318" FIXED GLASS, STAINED GLA55 2"XS"X65 718" 2 97 314" 72 518" 0 W08 PRIMARY BEDROOM -FRONT 2 1 100 112"X57 112" MILGARD 100" 57" TRIPLE CASEMENT-LHLIGHLIRHL 2"X12"X103 112" 2 96 114" 3q" 0.28 YES W09 PRIMARY BEDROOM - BACK 1 1 35 13I1611Xq9" FRANKLIN DOORS 33 13116" 96" EXT. HINGED -GLASS PANEL 2"X6"X38 13116" 2 99" 0" 0 YES W10 PRIMARY BATH -VANITY 1 1 72"X42" MILGARD 71 112" 41 112" LEFT SLIDING 2"X8"X75" 2 84 114" 42 1I2" 0.28 W11 PRIMARY BATH 1 1 60"X41 112" MILGARD 59 112" 41" LEFT SLIDING 2"XS"X63" (2) 84 114" 43" 0.2$ W12 LIVING ROOM TRANSOMS 4 1 59 112"X22 112" MILGARD 58 112" 21 112" FIXED GLASS 2"X8"X62 112" 2 114 112" 92 112" 0.28 W13 LIVING ROOM SLIDER 1 1 241"X80 3I4" FLEETWOOD 240" 80" EXT. QUAD SLIDER -GLASS PANEL 2"X12"X244" 2 80 314" 0" 0.35 YES W14 KITCHEN TRANSOM 1 1 72"X22" MILGARD 71 112" 21 112" FIXED GLASS 2"XS"X75" 2 114 114" q2 112" 0.2$ W15 KITCHEN 1 1 72"X42" MILGARD 71 112" 41 112" LEFT SLIDING 2"XS"X75" (2) 80 114" 38 112" 0.28 YES W16 GUEST BEDROOM -BACK 1 1 36"X57 112" MILGARD 35 112" 57" SINGLE CASEMENT-HL 2"X6"X39" (2) 96 114" 3q" 0.28 W17 GUEST BATH 1 1 35 112"X41 112" MILGARD 35" 41" SINGLE CASEMENT-HR 2"X6"X38 112" (2) 84 314" 43 1I2" 0.3 W18 ENTRY WRY -DOOR LITE 2 1 13"X97" FRANK LUMBER 12" 9611 FIXED GLASS, (MAYBE INCLUDED IN FRONT DOOR 2"X6"X16" (2) 97" 0" 0.3 'LOIN', DOOR SCHEDULE NUMBER COMMENTS (LOCATION) R10 DESCRIPTION DOOR PANEL WIDTH DOOR PANEL HEIGHT HEADER HERDER HEIGHT CASING SIZE, INTERIOR HINGE SIDE D01 GUEST BATHROOM DOOR 34"X98 112" HINGED -PANEL 32" q5 11161, 2"Xb"X37" 2 98 112" 518"X3 1I2" L D02 PRIMARY BEDROOM CLOSET 65 114"Xq8 112" POCKET -PANEL LOCKABLE ODOR 32" q5 1116" 2"Xb"X68 114" (2) 98 112" 518"X3 112" R D03 PRIMARY BEDROOM DOOR - MIRROR ON ONE SIDE (INSIDE ROOM 34"X98 112" HINGED -PANEL, MIRROR ON ONE SIDE (INSIDE BDR) 32" q5 ill (Oil 2"Xb"X37" (2) q8 112" 518X3 1I2" R D04 GUEST BEDROOM DOOR 34"X98 112" HINGED -PANEL MIRROR ON ONE SIDE INSIDE BDR 32" q5 1116" 2"X6"X37" 2 q8 112" 518"X3 112" L D05 LAUNDRY RM ODOR 34"Xq8 112" HINGED -PANEL 32" q5 1116" 2"X6"X37" 2 q8 112" 518"X3 112" R DO6 PANTRY DOOR 32"Xq8 112" HINGED -PANEL 30" 1515 ill (Oil 2"Xb"X35" (2) q8 112" 518X3 1I2" L D07 LINEN OR GOAT CLOSET 38"Xq8 112" HINGED -PANEL 36" q5 1116" 2"X6"X41" 2 q8 112" 518"X3 112" R DOS ENTRY DOOR 3811Xqq" EXT. HINGED -DOOR F04 36" q5 1116" 2"Xb"X41" 2 qq" 518"X3 112" L DO9 PRIMARY BATHROOM DOOR 42"Xq8 1I2" BARN-BOMBAY ODOR 42" qb 11161, 2"Xb"X45" 2 q8 112" 518X3 1I2" L D10 GUEST BEDROOM CLOSET 73"Xq8 112" SLIDER -PANEL 36 112" q5 11161, 2"X8"X76" (2) q8 112" 518X3 1I2" R D13 PRIMARY BEDROOM - BACK 35 13116"X99" EXT. HINGED -GLASS PANEL 33 13116" q5 1I16" 2"Xb"X38 1311 b" (2) qq" 518X3 1I2" L D14 PRIMARY BATH WATER CLOSET 34"Xq8 112" HINGED -PANEL 32" 1515 11161, 2"Xb"X37" 2 q8 112" L Building Section ALL NEW CONSTRUCTION Building Section 8/8/23 Cn O W }+ O N O O O O •— c � w� � � Q z� w 0 V � m� c � o rw LLI C/) _O _ co Lfi C 0) o o . Scc ; work was prepared by e or under my supervision. loot ('nntontc• ON RESUB J23 Aug 09 2023 NDS CITY OF EDMONDS RVICES DEVELOPMENT SERVICES IT DEPARTMENT1/411 = 1 1-019 (q) Scale: Date: 7/26/23 Job no.: T22J6 Drawn by: STT Sheet no.: as noted A-4.0 2018 Washington State Energy Code - Residential 2018 Washington State Energy Code - Residential ptive Energy Cade Compliance for AJI Climate Zones in Washineton . Single Fa milv - New & Additions (effective February 1. 20211 These requirements apply t C building types, including detached one- and two-family dwellings and multi le -family dwellings (townhouses). Project Information Contact lnjormatiaa Morts Remodel David ! Stephen Tapp ArchitecVP.E. 1034 B Ave S, Edmonds, WA 206-669-225-459-5151 Instructions: This single-family project wiII use the requirements of the Prescript) below and incorporate the minimum values listed. Based on the size of the structure, the approprla mbar of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as buiIdiing permit drawings: Table R402.1- Insulation and Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. ALPthorized Representative 20Date 1 112123 AI I Clim ate Zan es (Ta ble R402 A A) R-Value U-Factor Fenestration U-Factor ° n/a 0.30 Skylight U-Factore n/a 0.50 Glazed Fenestration SHGC hr° n/a n/a Ceiling a 49 0.026 Woad Frame wall &h 21 int 0.056 Floor 30 0.029 Below Grade Wall .h 10/15/21 int + TB 0.042 Slab'"R-Value & Depth 10, 2 ft n/a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less a than the label or design thickness of the insulation, the compressed R-value Df the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table_ b The fenestration U-factor column excludes skylights. "10/15/21 +5T0" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement waIL "10/15/21 +5TB" shah be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exteriDr of the wall. "5TB" means R-5 thermal break between floor slab and basement wall_ d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1_ e For single rafter- or joist -vaulted ceilings the insulation may be reduced to R-38 if thefull i Ian depth extends over the top plate Df the exterior wall_ R-7.5 continuous insulation installed over an existing slab is deemed to bee ent to the required perimeter f slab insulation when applied to existing slabs complying with Section .1. If foam plastic is used, it shall meet the requirements for thermal barriers protectingfoam S. For lag structures developed in rompliance with Stand 400r log walls shall meet the requirements for 8 dimate zone 5 of ICC 400. Int_ (intermediate framing) denotes fra nd insulation as described in Section AlD3.2.2 including standard h framing 16 inches on center, 78 a wall cavity insulated and headers insulated with a minimum of R-10 in sulation. Prescriptive Palh- Single Fatuity 2018 Washinglon State Energy Code-R 1 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Table 406.3 - Energy Credits (Single Family) Option Description 2. AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION OPTIONS Only one option from Items 2.1 through 2.4 may be selected in this category. Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall 2.1 be met with a high efficiency fan(s) (maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present). Ventilation systems using a furnace including an ECM motor are allowed, provided that they are controlled to operate at low speed in ventilation only mode. Credits: SF To qualify to claim this credit, the building permit drawings shall specify the option being selected and the maximum tested building air leakage, and shall show the qualifying ventilation system and its control sequence of operation. Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested 2.2 air leakage to 0.25 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.65. 1 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested 2.3 air leakage to 0.25 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.75. 1 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.6 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested 2.4 air leakage to 0.15 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.80. Duct installation shall comply with Section R403.3.7. 1 1 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilation system. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 0.5 1.0 1.5 2.0 5 Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: 6 credits All dwelling units that are not included in #1 or #3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R406.2 and 406.3 Heat3>< Credits - select ONE Optionsescriptions heating option otes p 1 NAECAb 0.02 1.0 3 Electric resistancel-SEE NEW CALCS PREPARED 4 DHP with zonal elec 5 All other heating sy BY DAV E AND J E N N I M O RTS :1. rgy cxearc ect Ulvt Options Energy Credit Option D ions energy option d ach category 1 Efficient Building E e o.5 ❑.2 Efficient B Envelope 1.0 ❑.3 Ef ' ' Building Envelope 0.5fficient Building Envelope 1.0 ❑.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑ 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Air Leakage Control and Efficient Ventilation 2.0 ❑ 3.11 High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC 1.0 ❑ 3.3' High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 x❑ 3.5 High Efficiency HVAC 1.5 ❑ 3.6a High Efficiency HVAC ❑ 2.0 ❑ 4.1 High Efficiency HVAC Distribution System 0.5 ❑ 4.2 High Efficiency HVAC Distribution System ❑ 1.0 ❑ See Reviewed sheets for updated credit information. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Table 406.3 - Energy Credits (Single Family) Option Description Credits: SF 5. EFFICIENT WATER HEATING OPTIONS Only one option from Items 5.2 through 5.6 may be selected in this category. Item 5.1 may be combined with any option. A drain water heat recovery unit(s) shall be installed, which captures waste water heat from all and only the showers, and has a minimum efficiency of 40% if installed for equal flow or a minimum efficiency of 54% if installed for unequal flow. Such units shall be rated in accordance with CSA B55.1 or IAPMO IGC 346-2017 and be so labeled. 5.1 0.5 To qualify to claim this credit, the building permit drawings shall include a plumbing diagram that specifies the drain water heat recovery units and the plumbing layout needed to install it. Labels or other documentation shall be provided that demonstrates that the unit complies with the standard. Water heating system shall include one of the following: 5.2 0.5 Energy Star rated gas or propane water heater with a minimum UEF of 0.80. s Water heating system shall include one of the following: Energy Star rated gas or propane water heater with a minimum UEF of 0.91 or Solar water heating supplementing a minimum standard water heater. Solar water heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification Corporation (SRCC) Annual Performance of OG-300 Certified Solar Water Heating 5.3 Systems or 1.0 Water heater heated by ground source heat pump meeting requirements of Option 3.3. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency and, for solar water heating systems, the calculation of minimum energy savings. Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier I of NEEA's advanced water heating specification or 5.4 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier I of 1.5 NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. s Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier III of NEEA's advanced water heating specification or 5.5 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of 2.0 NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. s Water heating system shall include one of the following: Electric heat pump water heater with a minimum LIEF of 2.9 and utilizing a split system configuration with the air -to -refrigerant heat exchanger located outdoors. Equipment shall meet Section 4, requirements for all units, of the NEEA standard Advanced Water Heating Specification with the UEF noted above or 5.6 2.5 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of NEEA's advanced water heating specification and utilizing a split system configuration with the air -to -refrigerant heat exchanger located outdoors, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. s s To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 7 K 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washi Single Family - New & Additions (effective February 1, 2021L Summary of Table R406.2 (cont.) Energy Credits :,WOM ONE Energy Credit Option Descriptions (cont.) Options a ption from User Notes d each category 5.1d Efficient Water Heating 0.5 ❑ 5.2 Efficient Water Heating 0.5 ❑ 5.3 Efficient Water Heating 1.0 n 5.4 Efficient Water H 1.5 ❑ 5.5 Efficient Heating 2.0 ❑ 5.6 t Water Heating 2.5 ❑ Renewable Electric Energy (3 credits max) 1.0 0 7.1 Appliance Package 0.5 ElTotal Credits 2.5 Calculate Total Clear orm a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category S. Option 5.1 may be combined with options 5.2 through 5.6. See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Please print only pages 1 through 3 of this worksheet for submission to your building official. For Building Officials Only Prescriptive Path - Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Table 406.3 - Energy Credits (Single Family) Option Description Credits: SF 3. HIGH EFFICIENCY HVAC EQUIPMENT OPTIONS Only one option from Items 3.1 through 3.6 may be selected in this category. z Energy Star rated (U.S. North) Gas or propane furnace with minimum AFUE of 95% or 3.1 Energy Star rated (U.S. North) Gas or propane boiler with minimum AFUE of 90%. z 1.0 3.2 Z Air -source centrally ducted heat pump with minimum HSPF of 9.5. 3 1.0 Closed -loop ground source heat pump; with a minimum COP of 3.3 or 3.32 Open loop water source heat pump with a maximum pumping hydraulic head of 150 feet 1.5 and minimum COP of 3.6. 3 Ductless mini -split heat pump system, zonal control: In homes where the primary space 3.4 heating system is zonal electric heating, a ductless mini -split heat pump system with a 1.5 minimum HSPF of 10.0 shall be installed and provide heating to the largest zone of the housing unit. 4 3.5 2 Air -source, centrally ducted heat pump with minimum HSPF of 11.0. 4 1.5 Ductless split system heat pumps with no electric resistance heating in the primary living areas. A ductless heat pump system with a minimum HSPF of 10 shall be sized and installed to provide heat to entire dwelling unit at the design outdoor air temperature. 3.6 z 2.0 To qualify to claim this credit, the building permit drawings shall specify the option being selected, the heated floor area calculation, the heating equipment type(s), the minimum equipment efficiency, and total installed heat capacity (by equipment type). z An alternative heating source sized at a maximum of 0.5 W/sf(eq uiva lent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. 3 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 4 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 4. HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM OPTIONS All supply and return ducts located in an unconditioned attic shall be deeply buried in ceiling insulation in accordance with Section R403.3.7. For mechanical equipment located outside the conditioned space, a maximum of 10 linear feet of return duct and 5 linear feet of supply duct connections to the equipment may be outside the deeply buried insulation. All metallic ducts located outside the conditioned 4.1 space must have both transverse and longitudinal joints sealed with mastic. If flex ducts 0.5 are used, they cannot contain splices. Duct leakage shall be limited to 3 cfm per 100 square feet of conditioned floor area. Air handler(s) shall be located within the conditioned space. HVAC equipment and associated duct system(s) installation shall comply with the requirements of Section R403.3.7. Locating system components in conditioned crawl spaces is not permitted under this option. 4.2 Electric resistance heat and ductless heat pumps are not permitted under this option. 1.0 Direct combustion heating equipment with AFUE less than 80% is not permitted under this option. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and shall show the location of the heating and cooling equipment and all the ductwork. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 3 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Table 406.3 - Energy Credits (Single Family) Option Description Credits: SF 1. EFFICIENT BUILDING ENVELOPE OPTIONS Only one option from Items 1.1 through 1.7 may be selected in this category. Compliance with the conductive UA targets is demonstrated using Section R402.1.4, Total UA alternative, where [1- (Proposed UA/Target UA)] > the required %UA reduction. Prescriptive compliance is based on Table R402.1.1 with the following modifications: 1.1 Vertical fenestration U = 0.24 0.5 Prescriptive compliance is based on Table R402.1.1 with the following modifications: 1.2 1.0 Vertical fenestration U = 0.20 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.28 Floor R-38 1.3 Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and 0.5 under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.25 Wall R-21 plus R-4 ci Floor R-38 1.4 Basement wall R-21 int plus R-5 ci 1.0 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 15% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.22 Ceiling and single -rafter orjoist-vaulted R-49 advanced Wood frame wall R-21 int plus R-12 ci Floor R-38 1.5 Basement wall R-21 int plus R-12 ci 2.0 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 30% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.18 Ceiling and single -rafter orjoist-vaulted R-60 advanced Wood frame wall R-21 int plus R-16 ci 1.6 Floor R-48 3.0 Basement wall R-21 int plus R-16 ci Slab on grade R-20 perimeter and under entire slab Below grade slab R-20 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 40%. Advanced framing and raised heel trusses or rafters Vertical Glazing U-0.28 1.7 R-49 Advanced (U-0.020) as listed in Section A102.2.1, Ceilings below a vented attic and 0.5 R-49 vaulted ceilings with full height of uncompressed insulation extending over the wall top plate at the eaves. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 4 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Table 406.3 - Energy Credits (Single Family) Option Description 6. RENEWABLE ELECTRIC ENERGY OPTION For each 1200 kWh of electrical generation per housing unit provided annually by on -site wind or solar equipment a 1.0 credit shall be allowed, up to 3 credits. Generation shall be calculated as follows: For solar electric systems, the design shall be demonstrated to meet this requirement using the National Renewable Energy Laboratory calculator PVWATTs or approved alternate by the code official. 6.1 Documentation noting solar access shall be included on the plans. For wind generation projects designs shall document annual power generation based on the following factors: the wind turbine power curve; average annual wind speed at the site; frequency distribution of the wind speed at the site and height of the tower. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall show the photovoltaic or wind turbine equipment type, provide documentation of solar and wind access, and include a calculation of the minimum annual energy power production. 7. APPLIANCE PACKAGE OPTION All of the following appliances shall be new and installed in the dwelling unit and shall meet the following standards: Dishwasher - Energy Star rated Refrigerator (if provided) - Energy Star rated Washing machine - Energy Star rated 7.1 Dryer- Energy Star rated, ventless dryer with minimum CEF rating of 5.2 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall show the appliance type and provide documentation of Energy Star compliance. At the time of inspection, all appliances shall be installed and connected to utilities. Dryer ducts and exterior dryer vent caps are not permitted to be installed in the dwelling unit. REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Eri& Carter BUILDING OFFICIAL Aug 10 2023 APPROVED DATE Credits: SF 1.0 0.5 REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT I� *' :PHEM T. TAPP OF _ AShINaTnra 1r__ ___" t17 r f if-+ I-Ir revisions 2/8/23 7/31 /23 8/8/23 O E M ■� }� O N O CD O 00 0 ■� �_ O U ■ 15 N S W aZz� LU lot > O 0 W M W n C co O o o N L U co s s m CD U a o cn L co N Cn This work was prepared by me or under my supervision. Sheet Contents: RESUB Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Scale: as noted Date: 1.23.23 T22J6 Job no.: Drawn by: STT Sheet no.: A-5.0 of 12 General Conditions STRUCTURAL STEELIELDING Code Requirements ASCE 7-16 Codes 2018 IBC AISIASD Sixteenth Edition ACI 318-16 NDS 2015 SEAW Rapid Solutions Methodology for Wtnld Design DESIGN LOADS l' RITI 52 LTi ANALYSIS PROCEDURE SEAW RAPID SOLUTIONS METHODOLOGY for WIND DESIGN BUILDING CATEGORY = 1 WIND SPEED = 85 MPH EXPOSURE = "B" TOPOGRAPHIC FACTOR Kzt = '1.3 Seismic Design ANALYSIS PROCEDURE:SEBCEQUIVALENT LATERAL FORCE PROCEDURE" Assumed Geotechnical Parameters SOILS REPORT NOT AVAILABLE ASSUMED ALLOWABLE SOIL BEARING PRESSURE = 2500 pcf ASSUMED ACTIVE SOIL BEARING PRESSURE FOR YIELDING WALLS = 35 pcf ASSUMED ACTIVE SOIL BEARING PRESSURE FOR NON -YIELDING WALLS = 50 pcf ASSUMED PASSIVE SOIL BEARING PRESSURE = 350 pcf SAFETY FACTOR = 1.5 ASSUMED COEFFICIENT OF FRICTION = .45 SOIL WEIGHT = 130 pcf Seismic Considerations SITE CLASS D OCCUPANCY CATAGORY = 1 IMPORTANCE FACTOR = 1 Ss = 1.28 g S, = .453 Fa =1.2 Fv = 1.5 Sms = Fa -SS = 1.2*1.28 = 1.54 Sm1 = Fv*Sj = 1.5*.453 = .68 SDs = Sms*.67 = 1.54*.67 = 1.03 SD, = SM,*.67 = .68*.67 = .46 SEISMIC RESISTING SYSTEM, NORTH -SOUTH: WOOD PANEL SHEAR WALLS, R-6.5 SEISMIC RESISTING SYSTEM, EAST -WEST: WOOD PANEL SHEAR WALLS, R=6.5 SHEAR WALL iVOTES - WALLS PX-X INDICATES SHEAR WALL. SEE LEGEND, SEE SHEAR WALL SCHEDULE FOR SHEAR WALL NOTES, ANCHOR BOLT PLACEMENT,. PRESSURE TREATED SILL SIZES, AND INSTALLATION DETAILS_ NOTIFY ENGINEER OF ANY REVISIONS TO SHEAR WALL OR FIELD MODIFICATIONS DUE TO UNFORESEEN CONDITIONS BEFORE PROCEEDING W17H CONSTRUCTION, DIAPHRAGM SHEATHING FAILS SHALL BE DRIVEN SO THAT THEiR HEAD OR CROWN IS FLUSH WITH THE SURFACE OF THE SHEATHING, THE FASTENERS USED IN THE SHEAR WALL DESIGN ARE 10d COMMONS OR 10d GALVANIZED BOX NAILS, ANY FASTENER SUBSTITUTION WILL HAVE TO BE RiEViEWED BY ENGINEER PRIOR TO CONSTRUCTION. SOLID BLOCK( BELOW SHEAF WALLS ABOVE. INDICATES SHEAF WALL TIE DOWN STRAP BETWEEN THE SHEAR WALL ABOVE AND THE FRAMING ABOVE OR THE WALLS BELOW. Shear Wall Dotes - Foundation (A) indicates `Simpson' holdown location( see manufacturer's installation requirements). Holdown anchors are to be iustalkrd at the end of plywood shear panels. Building Design Loads SNOW LOAD = 25 SPF ROOF (DL) = 15 PSF, (LL) 25 PSF FLOOR (DL) = 12 PSF, (LL) = 40 PSF EXTERIOR WALL (DL) = 15 PSF INTERIOR WALL = 7.5 PSF EXTERIOR DECK (DL) = 15 PSF, (LL) = 65 PSF CORRIDORS, STAIRS, EXITS (DL) = 12 FSF, (LL) = 100 PSF See Shear Nall Schedule for shear wall notes, schedules, anchor bolt placement, and pressure treated sill sines. All shear wall panelat other than PI- ' are to he installed with pressure treated 3X sills. All holdown 4X or 6X posts to be Doug fir 02 or better. Anchor bolts to be minimum Wd. X 10" * 48" o.c. (unless noted otherwise in Anchor Soft Sheaar Nall Schedule, Sheet #€S-1). Concrete strength f'c = 3OW psi for concrete exposed to the elements. Concrete strength f 'c 2500 psi for concrete not exposed to elements. Notify engineer of any revkiona to shear wall or holdown plan or old modifications due to uufonv n conditions before proceeding with construction. Increase depth of foundation at holdown anchor bolts to insure proper concrete coverage. Simpson Strong Tie connectors arc specifically required to meet the structural calculations of this plan. Before substituting aDethcr brand, confirm load capacity based on reliable published testing data of calculations. The En&eer of Record should evaluate and give approval for substitution prior to installation. MATERIAL SPECIFICATIONS Prefabricated Floor Trusseslf'loor Joists (if rpg uired) > Submit to engineer of record complete slop drawings and calculations stamped by a Washington State registered professional engineer for approval prior to fabrication. > Pnwide for all temporary and permanent truss and joist bracing and bridging (per manufacturer's recommendations). > Store and erect trusses in accordance with the manufacturer's details and installation recommendations. > Substitution in prefabricated assemblies to be approved by engineer of record prior to installation. > Plywood to be glue nailed to top flange of prefab floor joist or truss. > Provide additional web reinforcing at T,II joists at or over supports. Floor Loads (See loading table above) Wood Dotes > New exterior walls to be framed with 2 x 4 or 2 XIS studs 16" O . (unless noted otherwise). > New interior walls to be framed with 2 x 4 studs @ 1 " u.c. (unless noted otherwise). > All frame nailing shall be in accordance with 'fable No.2304.9.1, 2018 IBC > When a girder is spliced over a support, au adequate tie shall be provided. > Provide solid blocking over all supports. > Provide fire blocking within framing cavity at ff-O"vertically and horizontally). Fire Aep openings around vents, pipes, ducts, chimneys,ete. with non-combustible materials. > Framing anchors shall be provided to support joists which frame into the side of a wood girder or framing nand. > Wood members shall have sufficient bearing area based on allowable values for compression perpendicular to- grain per 2001 DS. > Provide double joists under all interior bearing walls. > Where boring through studs is required for plumbing or rlmirical wiring in bearing walls use 2 X 6 or double 2 X 4 studs. > All joists, studs, blocking, bracing, and rafters shall be Hem Fir #2 or better; Fb - 850 psi (1000 psi repetitive), Fv = 75 psi E =1, 300,000 > All sawn beams, headers, posts, lintels, and girders which are 4" nominal width shall he Doug -Fir Larch #2 or better; lib = 850 psi, Fv = 9rs psi, E = 1, 600,000. > All wn reams, headers, posts, lintels, and girders which are 6" nominal width shall be Doug -Fir Larch #1 or better: lib = 850 psi, Fv = 85 psi, E = 1, 600,000. All glue -laminated timbers to be kiln dried Doug -Fir top and bottom (24 F-V4) for simple span beams; (24 F-VS) for multiple span or cantilever beams. Fb = 2400 psi, Fv =1 5 psi, E -1,8 ,000. > All framing lumber shall be k.ilir dried to a maximum 19 % moisture content prior to installation. > Steel framing accessories and structural fasteners shall be as manufactured by Simpson Company (or approved. equal). Connectors shall be installed in accordance with manufacturer's recommendations. Provide all plan designated manufacturer's connectors. > Simpson Strong Tie connectors are specifically required to meet the structural calculations of this plan. Before substituting another brand, confirm load caparity lased on reliable published testing data of calculations. The Engineer of Record should evaluate and give approval for stuiustitution prior to installation. Holdowns > Holdowns to be by Simpson Company (or equal. Any substitutions in hardware manufacturer must be approved by the Engineer of Record prior to installation. .Plywood Notes > All plywood shall tm irtstarlled per American Plywppd Association standards. > All plywood shall be A.P.A rated C-D Struct 1(mina. > All panel edges to occur with long edges over wood supports, short edges to he hlocked. > All roof V"ood to be `14" thick with span rating 24/0. > 'Vail panels with 10d common naih at 12"' ox. in the field, let' o.c. at all panel edges. Nail at 4" u.c. to all exterior walls and other shear walls,. > All fhunr plywood to be minthick with span rating 32/16. > Nail panels vvith 10d.. gals, nails at 6" o.e. at panel edges, 12" u.c. in the field. Sec Shear wall schedule for nailing patterns shear walls. > At floor sub -floor glue floor plywood to favor joists with an approved elastomeric adhesive suitable for use in wet weather. > See shear wall schedule and notes for wall plywa d and naibng schedule. > All ply-%ood at waterproof decks to be pmsure irmted. > Plywood floor aad roof sheathing shaGlI be laid up with face grain perpendicular to supports. > All floor plywood shall be glue nailed to suppording joist in necordaGnce with the American Plywood Association. flue snail meet the requirements of Adhesive Specification ANC -01. Concrete/Foundation Notes > Foundation design is in accordance with chapter 19 of the 2018 IBC All work shall he performed in accordance with all current building and safety codes. > Concrete strengths shall be verified by standard 28-day cylinder tests, unless approved otherwise. > Anchor bolts to be 518"diameter with 10" embedment @, 4811 o.c. (see shear wall schedule for anchor bolt size and spacing at other than P14" shcarwalls). All anchor bolts to be ASTM A-307. > ALLOWABLE 80IL'SEARING PRESSURE =15000 PSF > Backfill behind unbraced retaining walls prior to attaching floor diaphragm. > Exterior footings to be entrerrehed a minimum of 18" below existing grade and bear on firm undisturbed sail. > All reinforcing bars to he Grade 60 deformed bars. The tic wire is to be 16 fiat. double annealed wire. Lap all reinforcing 36 diameters. At corners of wails extend horizontal bars 2" from outside farce of wall and lap with elbow bars of30 diameters at the same sine and spacing. Provide 245 bars around all wall openings. Provide footing dowels to match vertical reinforcing. Concrete cover 31r' concretc poured against earth 2" formed concrete with earth backfill 1 1/2" outside face of walls exposed to weather, slabs can a moisture barrier 1" walls, outside face > Provide 4"diameter perforated PVC drain in granular fill at the base of all new exterior footings (existing and new). Concrete mix Mix design shall be in conformance with ACI-318-99. Submit mix designs to eu ineer of record 2 weeks pijer_to.plaftwent indicating where each concrete mix ig used and the maximum aggregate sme. type PC max.water/cem.ratio min. non-a►ir ent, air ent. skslcmyd. ftgs .65 .42 6 found.watls 2+500 slab on grade 3000 .65 .50 5 Y2 > Water reducing mixtures may be incorporated into the mix designs in accordance with ASTM C 494 and manufacturer's recommendations. >Water/Cement ratio shall be measured by weight and shall be based on the total cementiotes mattrsal. Water/Cement ration shall be determined by the supplier based on the strength requirements and shall no exceed the maximum water/cement ratio shown above. > Contractor will call far inspectio3n prior to placing any footing and foundation wall concrete, > Provide rigid insulation around the perimeter of ail slabs within heated spaces, > Permanent cut and fill slop" should not exceed 2:1 (H.*V). > All reinforcing shall he detailed in accordance with ACI detailers manual. > All excavations shall Ike adequately barricaded and marked. All work area and surfaces shall be cleaned upon completion of the project. All debris and waste materials shall be removed off the site to in Rpproved disposid am by the contractor. -Use air -entrained (3%-696) in all Flat work exposed to weather. - Master flow 928 or equal. > Provide minim uw of 1/2" air space between non -pressure treated woad and concrete, or provide waterproofing membrane between concrete and non -pressure treated wood. > Top of concrete to be field verified by contractor. > Contractor to field verify existing grade cut and soil conditions with before promeding with concrete retaining wall forming aPid reinforcing steel placemeaL' > Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the walk, >In the case of discrepancies between the drawings and the anticipated field conditions the contractor shall notify the architect before proceeding with construction. >DO NOT SCALE the architects or engineer's drawings - mated dimensions take precedence over scaled dimensions. Fasteners Fasteners for pressure treated wood must be ZMAX hot dipped galvanised (G18) or stainless steel. Prefabricated Roof Trusses fif required) > Submit complete shop drawings and calculations stamped by a Washingtun State registered prokssional engineer for approval prior to fabrication. > Ileaign for the spans and conditions shown on plans. > Deflections under total loads not to exceed L1360. > Provide far all temporary and permanent truss bracing and bridging. > Store and erect trusses in accordance with the manufacturer's recommendations. Roof Dead Load = (15 psf) Livc Lead = (25 pat) Bottom chard head Load = 7 psf Top Chord uplift = 7 psf STEEL DESIGN, FABRICATION AND ERECTION SHALL CONFORM TO THE REQUIREMENTS OF CHAPTER 22 OF THE 2018 IBC SUBSTITUTION OF MEMBER SIZES OR STEEL GRADE WILL NOT BE ALLOWED WITHOUT PRI OR APP ROVAL OF THE ENGINEER OF RECORD - THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ERECTION AIDS AND JOINT PREPARATIONS THAT INCLUDE BUT ARE NOT LIMITED TO ELECTION ANGLES, LIFT HOLES AND OTHER AIDS, WELDING PROCEDURES REQUIRED ROOT OPENINGS, ROOF FADE DIMENSIONS, GROOVEANGLES, BACKING BARS, SCOPES, SURFACE ROUGHNESS VALUES AND UNEQUAL PARTS, EXPANSION BOLTS SHALL BE ICB0 APPROVED AND INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS, UNLESS OTHERWISE SPECIFIED ON DRAWINGS OR DETAILS, SIZE AND EMBEDMENT DEPTHS SHALL BE APPROVED THE THE ENGINEER OF RECORD. MATERIALS STRUCTURAL STEEL ATM A 992GRADE50 CONNECTION MATERIAL, ASTIVI A 36 EMBEDDED ITEMS, CHANNELS, ANGLES, BASE PLATES STRUCTURAL TUBES ASTM A 500, GRADE B STRUCTURAL BOLTS ASTM A 32f>-N WOOD CONNECTION BOLTS ASTM A 307 ANCHOR BOLTS ASTM A 307 THREADED RODS ASTM A 36 WELDING ELECTRODES TOW, LOW HYDROGEN BEAM CAMBER NOTED ON DRAWINGS IS THE UPWARD CAMBER REQUIRED IN THE BEAM AS DELIVERED TO THE JOB SITE, THE CONTRACTOR SHALL CONSIDER CAMBER LOSS DUE TO SHIPPING AND HANG}LINO. STRUCTURAL STEEL AND CONNECTIONS EXPOSED TO WEATHER SHALL BE HOT 01PPED GALVANIZED AFTER FABRICATION IN COMPLIANCE WITH ASTM A 123. ALL FIELD WELDS ON GALVANiZED MATERIAL SHALL BE COATED WITH BRUSH APPLIED ZING -RICH PAINT COMPLYING, WITH ASTM A 780 (GALVAOON OR EQUIVALENT). SHEAR WALL SCHEDULE 2018 IBC 1?Ir'all Sheathin to be 1/2" C-D Structural L 24/0 Roof Sheathing to be 1/2" -D) Structrual 1311.6 use 10d common nails WALL NAIL PANEL MAIL SPAC BL "G REO111(RED ANCHORS ALLOWABLE TYPE Size Panel Field TING eplBtw P.T.Sill Bottom 11NIT STj AR Edges Studs Pkafts Plate 01f) PI-6" 104 fill 121" 6" 2 X 6 (4) a/8"d. 48" 16d (a' (" 282(11F), =kI[ I P14'" 14d 4"" 12"" 4" 3 X 6 (4) 5/$"'d. . 3211 (2)16d. @ 8"' 41), 510(DF) P1 " 10d 31" 12" 3`1 3 X 6 (4) 5/8"d. 241' (2)16d. @ 6" 561 HF), 665(DF) P1-2" 10d 2" 12" 2" 3 X 6 (4) 3/4"d. 24" (2)16d. 5" 710(IiF), 870(DF) Shear Wall Notes. 1. P1 indicates plywood on one side of shear wall only. 2. P2 Indlestes plywood on two sides of shear wall. Framing members ,4hill be .3X. Offset panel joints to fail vn different studs. 3. Plywood may be installed either horizontally or ve.rticaIly on Hem -Fir #2 studs. 4. For nailing at 4",,3" or 2" on center, use 3 X framing Fnembcrs at all panel edges. stagger fasteners nt all pace] joints. 5. For nailing at 4", 3", or 2" on renter use pressure treated 3X sill at foundation. 6. Solid black all panel edges with full depth blocking. 7. Use 10d common nails for shear wall fasteners. S. Nails must be flush driven with diaphragm sarfaee. 9. Anchor holts to have minimum 3" X 3" X 1/4" plate washtm 10. Finger jointed studs are not to be used at holdown locations. 11. Nails for panel edges shall be I Od common JO.131"d. X 3" long). Nails for plates shall ter 16d. common (0.148d. X 3 V4" long). 12. Where bottom plate nailing regaires (4) nails at a specific spacing, block fluor space below the sole plate consisting of a minimum (Pf two framing memhe". Nailing pattern shall consist of two rows in each member offset 112" and staggered. 13. Do not ins#all floor diaphragm nailing over bottom sill nailing, 14. ALL STUDS TO BE 2% 11EM FIR #2 OR RFTTER2 REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 7/31 /23 8/8/23 0 E o o 0 a) m • - A-+ o N W s z c� Q LU >� 4.0 c 0 0 r W W o N U (6 N h La cn M CV Cn This work was prepared by me or under my supervision. Sheet Contents: RESUB Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Scale: as noted Date: 11 /9/22 Job no.: T22J6 Drawn by: STT Sheet no.: S-1.0 of 12 94133 Mid Rail 95,50f,13 in [2426 mm] 3.88 in 94012 Top Rail 94252 Baluster [98 mml� c an. ,7 in rnd]6 ml A ii_R1 f_n6 in fRSq mml� 42.t [101 MA) F A - —94252 Baluster 5.561.06 in [141 mm] D I C L 0 in 7 mm] 32.25 in [819 mm] E 940t3 Bottom Rail B2.00 in1!379'in [51 mm] m] 95.50+.13 in [2426 mm] �� 3,88 in 3,69 in [98 mm] [94 mm] Centered between support posts 96.00 in MAX 4.00— in [101.6—s mm] L[4sa mm] Figure 2 Westbury' Riviera Series Style C30 Aluminum Railing System 4.00-w in [101.6=0•5 mm] 125— in [3.2-4 mm] Figure 22 - 4x4 Aluminum Post Assembly A%_aA Post must be set to have screw line perpendicular with rail line. 2.00 in O (3) C 10 150.8 mm] 2.00 in —$— -- Railing E [50.8 mm] -- OU (4) UO v1Ew A -A SCALE .75 1/4" x 1/4" +/- 1/16" 10898 Leveling Bolt 1/4"x1/4" ±1116" Welded all 4 sides full length to plate with 3/64" ER 5356 Wire 37" [940 mm] 74021 Post (36" [914 mm] Guardrail) 43" [1092 mm] 74023 Post (42" [1067 mm] Guardrail) Tolerance = t 1/16" o ` CD 3.88 in 55236 Leveling [98.4 mm] Shim Plate 55258 #14 SS Screws (2 req.) Figure 23 — 2" Aluminum Support Post Assembly RAILING DETAIL NTS ne/End Post 1016 1018 rossover Post: I 1020 1021 Simpson top flange hanger HB5.5/16 Simpson top flange hanger HB5.5/18 line of deck a DB-100 —-�-—--—-—-—-—-�-— —-—————— — — — — —— ,+L,1 \ / TI 1 � / I I \ D,,i100 I DJ-101 I' 10 `'r' Q 0 ,I C) 11 / DS-100 \ \ m II Q I S-,) I f;\ - -- - - ------ - - - ;}I II I II crostc16 \ /' 11114" tension straps on \ I underside of deck joists , \ I II I \ / I o„ 1 256 1 /4" n � I Simpson top flange hanger HB5.5/16 DC-100 with Simpson 'MPB66Z' embedded post base with CCQ5-6SDS2.5 column cap - typical 3 places RFC-100 _ P5 / Aso \ DB-106 DC-100 with Simpson ABU66Z 12 , B" 2" _ nr post base with CCQ5-6SDS2.5 `, I I o column cap - typical 3 places , DL-100 — — — — — — — — — — — — — — — --HDR-001--------------- HDU5 holdown w/dbl studs G I 33 3l4" 4" I I I I I I I _ I I N UC--10-9 w[thS[mpson-ABl6-6Z- post base with CCQ5-6SDS2.5 column cap - typical 3 places U 6 CD -(n :o _o X N 1) c X 0) CONTINUOUS FOOTING 30" wide x 16" thick continuous footing with 444 longitudinal and #3 ties (@ 12" o.c z--a1 CnCIO X LU P 143" epoxy grout 244 horizontal bars into existing foundation HDU5 holdown w/dbl studs SLAB TO BE INSULATED AROUND NTI PERIMETER WITH R-10 RIGID INSULATION AS WELL AS FLOW ENTIRE NEW SLAB " I •a• r--�J /- I 5 shear wall above / HDU5 holdown w/dbl studs epoxy grout 244 horizontal bars into existing foundation J. L---------------- HDU5 holdown w/dbl studs HDU5 holdown w/dbl studs UP 1 shear wall above I' Slab on grade 4"thk concrete slab ' with 6"x6"xW2.9xW2.9 WWF on 6 mil vapor barrier on 12 6" compacted fill , / -4.0 11 RFC-100 G�6 G G�6 G III Inspection reports for all welding to be provided to the city for review. epoxy grout 244 horizontal bars into existing foundation epoxy grout 244 horizontal I I \ bars into existing foundation I I HDU5 holdown w/dbl studs �I I I a --------------- .:•:I q4 1/2" 1 21T HDU5 holdown 604 w/dbl studs Deck Framing Plan/Partial Lower Floor SW Plan 1/4" = 1'-011 O Beam Schedule DB-100 P.T. 2 1/2 x 18 24FV4 GLB DB-101 P.T.5 1/8 X 18 24FV4 GLB/OR/ W8X48 STEEL BEAM DB-102 not used DB-103 P.T.5 1/8 X 16 1/2 24FV4 GLB DB-104 HSS 8X4X5/8 STEEL TUBE DB-105 DBL EXISTING JOISTS DB-106 P.T. 4X10 DF#1 DC-100 P.T.6X6 DF#1 POST DJ-100 P.T. 6X6 DF#1 @ 12" O.C. DJ-101 P.T. 2x10 DF#1 @ 16" O.C. DL-100 P.T. 2x10 DF#1 LEDGER W/ 2 ROWS 5/8"d. LAG BOLTS @18" O.C. DS-100 P.T. 6X6 DF#1 FRB-100 HSS 8X4X5/8 STEEL TUBE H DR-001 RFC-100 HSS6X5X1/2 STEEL TUBE All new beams and headers to be 4x10 DF#1 unless noted otherwise in the framing plans\ P.T. means pressure treated SHEAR WALL NOTES - FOUNDATION INDICATES'SIMPSON' HOLDOWN LOCATION (SEE -00 MANUFACTURER'S INSTALLATION REQUIREMENTS). HOLDOWN ANCHORS ARE TO BE INSTALLED AT THE END OF PLYWOOD SHEAR WALL PANELS. SEE SHEAR WALL SCHEDULE FOR SHEAR WALL NOTES, SCHEDULES, ANCHOR BOLT PLACEMENT, AND PRESSURE TREATED SILL SIZES. ALL SHEAR WALL PANELS OTHER THAN P1-6" ARE TO BE INSTALLED WITH PRESSURE TREATED 3X SILLS. ANCHOR BOLTS TO BE MINIMUM 5/8"0 X 10" @ 48" O.C. (UNLESS NOTED OTHERWISE IN ANCHOR BOLT SCHEDULE, SHEET S-3). CONCRETE STRENGTH F'C = 3000 PSI FOR CONCRETE EXPOSED TO THE ELEMENTS. CONCRETE STRENGTH F"C = 2500 PSI FOR CONCRETE NOT EXPOSED TO ELEMENTS. NOTIFY ENGINEER OF ANY REVISIONS TO SHEAR WALL OR HOLDOWN PLAN OR FIELD MODIFICATIONS DUE TO UNFORESEEN CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION. INCREASE DEPTH OF FOUNDATION AT HOLDOWN ANCHOR BOLTS TO INSURE PROPER CONCRETE COVERAGE. SIMPSON STRONG TIE CONNECTORS ARE SPECIFICALLY REQUIRED TO MEET THE STRUCTURAL CALCULATIONS OF THIS PLAN. BEFORE SUBSTITUTING ANOTHER BRAND, CONFIRM LOAD CAPACITY BASED ON RELIABLE PUBLISHED TESTING DATA OF CALCULATIONS. THE ENGINEER OF RECORD SHOULD EVALUATE AND GIVE APPROVAL FOR SUBSTITUTION PRIOR TO INSTALLATION. SHEAR WALL NOTES - WALLS PX-X INDICATES SHEAR WALL. SEE LEGEND. SEE SHEAR WALL SCHEDULE FOR SHEAR WALL NOTES, ANCHOR BOLT PLACEMENT, PRESSURE TREATED SILL SIZES, AND INSTALLATION DETAILS. NOTIFY ENGINEER OF ANY REVISIONS TO SHEAR WALL OR FIELD MODIFICATIONS DUE TO UNFORESEEN CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION. DIAPHRAGM SHEATHING NAILS SHALL BE DRIVEN SO THAT THEIR HEAD OR CROWN IS FLUSH WITH THE SURFACE OF THE SHEATHING. THE FASTENERS USED IN THE SHEAR WALL DESIGN ARE 10d COMMONS OR 10d GALVANIZEDREVISION E BOX NAILS. ANY FASTENER SUBSTITUTION WILL Aug 09 2023 HAVE TO BEREVIEWED BY ENGINEER PRIOR TO CITY OF EDMONDS CONSTRUCTION. DEVELOPMENT SERVICES DEPARTMENT SOLID BLOCK BELOW SHEAR WALLS ABOVE. INDICATES SHEAR WALL TIE DOWN STRAP BETWEEN THE SHEAR WALL ABOVE AND THE FRAMING ABOVE OR THE WALLS BELOW. revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 7/31 /23 8/8/23 O E +� o O 00 • — +_� o Vi • }. LU t aZz� w i �a0 E 2 L! LL, C 0 co O o o U M ^, C CD s N �wa) � `U U a o COO 4— M N 4) Cn This work was prepared by me or under my supervision. Sheet Contents: RESUB Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Scale: as noted Date: 11 /9/22 Job no.: T22J6 Drawn by: STT Sheet no.: S-2.0 25'9"8 op 10 163 T 2' Koot naming Dian/Main door 5w Flan 1/4" = 1'-0" REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Eri e C-,&� BUILDING OFFICIAL Aug 10 2023 APPROVED DATE Beam Schedule FRB-100 HSS8X4X5/8 STEEL TUBE :DR-1 NOT USED 100A 7X18 2. L 00B 7x9 2.0E P 01 3.5 x 11.875 2.0E PSL DR-102 3.5 x 11.875 2.0E PSL DR-103 3.5 X 11.875 2.0E PSL 100 NOT USED 101 4X10 DF#1 102 NOT USED 103 NOT USED C-100 HSS6X5X1/2 STEEL TUBE -100 NOT USED -100 1.75 X 9.25 2.0E PSL ,II new beams and headers to be 4x10 DF#1 Ness noted otherwise in the framina Dlans SHEAR WALL NOTES - WALLS PX-X INDICATES SHEAR WALL. SEE LEGEND. SEE SHEAR WALL SCHEDULE FOR SHEAR WALL REVISION NOTES, ANCHOR BOLT PLACEMENT, PRESSURE Aug9 2023 TREATED SILL SIZES, AND INSTALLATION DETAILS. g CITY OF EDMONDS NOTIFY ENGINEER OF ANY REVISIONS TO SHEAR DEVELOPMENT SERVICES DEPARTMENT WALL OR FIELD MODIFICATIONS DUE TO UNFORESEEN CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION. DIAPHRAGM SHEATHING NAILS SHALL BE DRIVEN SO THAT THEIR HEAD OR CROWN IS FLUSH WITH THE SURFACE OF THE SHEATHING. THE FASTENERS USED IN THE SHEAR WALL DESIGN ARE 10d COMMONS OR 10d GALVANIZED BOX NAILS. ANY FASTENER SUBSTITUTION WILL HAVE TO BE REVIEWED BY ENGINEER PRIOR TO CONSTRUCTION. SOLID BLOCK BELOW SHEAR WALLS ABOVE. INDICATES SHEAR WALL TIE DOWN STRAP BETWEEN THE SHEAR WALL ABOVE AND THE FRAMING ABOVE OR THE WALLS BELOW. revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 7/31 /23 8/8/23 O E � o o 00 p 00 •— A-+ o • C/) a z wLU c� Q AMA '�e >� c O 0 rw W f 0 1_L M Ln C 01 \ O O U M w i� � U � c� CLL co 4) This work was prepared by me or under my supervision. Sheet Contents: RESUB Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Scale: as noted 11 /9/22 Date: Job no.: T22J6 Drawn by: STT Sheet no.: S-3-0 F n ff #3 C:JIES @ 12" OC SCALE: 1 "=V-0" 4" CONIC SLAB 444 BARS 1 1/2" LONGITUDINAL TOP CLR &BTM R-44 INSULATION TTS PRE -FABRICATED TRUSSES @ 24" O.C. ROOF SHEATHING PER PLAN � H1 SEISMIC CLIP AT EVERY TRUSS EACH END 2X STUDS @ 16" O.C. with/R-21 INSUL. BATTS ROOF TRUSS 4" thick concrete slab w/ 6"x6" W2.9xW2.9 WWF on 6mil vapor barrier on 6" compacted fill a .. > X -X ..d .. X- d M DETAIL SCALE: 1 "=V-0" 3/4" THICK BASE PLATE WITH 2-3/4" diameter X 15" LONG - EMBED INTO CONCRETE 12" Il�hhi L� fad low. h�, r �1 1141 .'I 'A !�I _ yli I 190too ►4Uj (r-P LEvtLf i . `I I I II 3 STEEL COLUMN BASE DETAIL NTS 8d @ 4" OC SHEATHING TO BLOCKING 2X VENTED BLOCKING 48" #4 X 12" (2)#4 BARS CONT r— FINISH GRADE (2)#4 BARS CONT col. to base plate 3x nailer with 1/2"d. threaded studs welded on @ 15" o.c. 2x nailer w1114" teks ( 12" o.c.(2 rows) (CJP) BEAM TO COL. Clarify with FOR the type of anchor to be embedded into the concrete. Provide document to inspector at the time of inspection. rnneTr1a f RACTIO rnneTIA r'C1R STRAPPING AT WALL SCALE: V=V-0" (W-14) 10 DECK FRAMING CROSS—SECTION 3/8" = 1'-0" IS /OOD I PLATE iT TOP 3/1$" 14 hss ool- 2-314-d. Base Plate 20 threaded rod l u Section)01 HSS TUBE BEAM (SEE ELEVATION) 2 COLUMN TO BEAM CONNECTION nts MIN DBL STUDS 3DS %X3 SCREWS 3EE HOLDOWN CALL -OUTS )N PLAN )R TR BARRIER MAY BE ZEQUIRED EPDXY GROUT W/ SIMPSON SET-XP EPDXY (MIN EMBED = 10") 'R TR 2X OR 3X SILL (SEE SHEAR WALL SCHEDULE "0 (OR) %"0 ANCHOR 3OLT _U FOUNDATION TYPICAL HDU INSTALLATION AS A HOLDOWN (SHOWN "FLUSH", TOUCHING SILL PLATE) NOTE: SEE MANUFACTURER'S CATALOG FOR ADDITIONAL INFORMATION HOLDOWN INSTALLATION 6 SCALE: NTS I I I I I I I I I I I I HSS 6x5x1/2 steel tube I I I I I I I I I I I I I I i ANGLE TO BEAM AND COLUMN L4X4XO'-5" 3/16 steel angle --------------------- HSS 8x5x5/8 steel tube ANGLE TO BEAM AND 3/16 COLUMN ORigid Frame Elevation nts FLOOR SHEATHING NAILINGAT 61 N. NMIMUM ON CENTER TO JOIST W TH HOLD-DOVM FLOOR JOIST HOLD-LXYM OR SIMILAR 704SION DEVICE DECK JOIST 5 DECK TO FLOOR CONNECTION nts a 9 BEAM TO POST CONNECTION DETAIL nts R-10 RIGID INSULATION 6 MIL VAPOR BARRIER '. ova �. 2X STUDS 16" O.C. %" EXTERIOR PLYWOOD SHEAR WALL 4" CONIC SLAB W/ 6"X6" W2.9XW2.9 WWF PR TR SILL PLATE W/ %" 0 AB PER SHEAR WALL SCHEDULE (2) #4 CONT TOP #4 @ 10" OC (HORIZ) — #4 E� 3" (VERT) @ 16" OC 4"0 PERF PVC IN 6" DRAIN ROCK 6" GRAVEL a 1—lI�—III II� 411 8" V (2)#4 BTM LONGITUDI 1'-4" TYPICAL FOUNDATION i SCALE: 1 "=V-0" J REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT VISED PLAN APPROVED IT OF EDMONDS BUILDING DIVISION E r Cv� BUILDING OFFICIAL Aug 10 2023 APPROVED DATE revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 7/31 /23 8/8/23 O E o . o OCIO •— I= •— �_ o Cn .c z QUj >� C� on O �14.� W 0. 0. M w i 0 M O o o .� C,' N L U M M C, CD 62� U o_ ocn L M N This work was prepared by me or under my supervision. Sheet Contents: RESUB Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Scale: as noted Date: 11 /9/22 Job no.: T22J6 Drawn by: STT Sheet no.: S-4.0 of 17 -II _/ 1 11 1,- 2X6 OUTLOOK PREFABRICATED TRUSSES RAFTERS @ 24" O.C. @ 2X 24" O.C. \ - STUD (2) 2X BLOCKING LA OULU F`LY11 L SHEAR WALL AT WINDOW OPENING SCALE: 1/2"=l'-0" H1 SEISMIC CLIP AT EVERY TRUSS END PLYWOOD ROOF SHEATHING 2x FASCIA 2X VENTED BLOCKING EXTERIOR PLYWOOD SHEATHING 2X STUDS @ 16" O.C. with/R-21 BATT INSULATION OROOF TRUSS at RAKE OUTLOOK 1 -1 0 PREFABRICATED TRUSSES @ 24" O.C. R-44 BATT INSULATION PLYWOOD ROOF 12 2.5 SHEATHING �/ / 12 1.5 / DECK OVERHANG H1 SEISMIC CLIP AT RAFTERS -SEE FRAMING EVERY TRUSS END PLANS FOR SIZE - BACK SPAN 8'-0" 2X VENTED BLOCKING 2X STUDS @16" O.C. with/R-21 BATT INSULATION EXTERIOR PLYWOOD SHEATHING O ROOF TRUSS at EAVE 12 2.5 PLYWOOD ROOF SHEATHING, ,PREFABRICATED TRUSSES @ 24" O.C. R-44 INSULATION BATTS 2X BLOCKING BETWEEN DEEP HEEL TRUSSES EXTERIOR PLYWOOD SHEATHING H1 SEISMIC CLIP AT 2X STUDS @ 16" O.C. EVERY TRUSS END A with/r-21 INSUL BATTS SEE SHEARWALL SCHEDULE FOR ROOF AND WALL SHEATHING NAILING SCHEDULES � ROOF TRUSS SCALE: 1 =1-0 In\ AnJ /TX/lid nV 41)A C%I InnTn /l SHEAR WALL THRU ROOF TRUSSES SCALE: 1"=l'-0" (R-09) REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Erito, C4*-fer BUILDING OFFICIAL Aug 10 2023 APPROVED DATE revisions 8/8/23 O E O 00 CY) ■ �_� O V/ z QD is Z LLI Q O 0 r W W f O LL M Ln C 01 \ O O U M w i� � U C' c� CLL co 4) C0 This work was prepared by me or under my supervision. Sheet Contents: RESUB Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Scale: as noted Date: 8/7/23 Job no.: T22J6 Drawn by: STT Sheet no.: S-5.0 of 12