REV1 REVIEWED BLD2022-1670+Structural_Analysis_or_Calculations+8.8.2023_4.54.29_PM+3714547N REVIEWED BY CITY OF EDMONDS REVISION Aug 09 2023 Stephen Tapp Architect/P.E. RESUB 2330 East Madison Street Aug 09 2023 ° Seattle, Washington 98112 (206) 320-0534 (206) 459-5151 BLD2022-0989 Structural Calculations (additional beam calculations and lateral analysis of main floor) DATE: 8/8/23 for Morts Residential Remodel/ New Deck 1034 B Street South Edmonds, Washington 98020 fk Date: August 2023 Project: T22J6 Building Code Reference: 2018 IRC 8/8/2023 4:12 PM - 1 - P STEPHEN TAPP ARCHITECT/P.E. 2330 East Madison Street SEATTLE, WA 98112 (206) 320-0534 JOB SHEET NO. _ CALCULATED CHECKED BY. SCALE _ STT Of — DATE _ DATE P3 P2 -- --- -' _ -- --- P1 P4 _♦ llI I P5 I �I wind load elevation West -East LOAD TRIB SYMBOL PRSM HEIGHT AREA Vey P, 14 psf 4.5 ft 51 ft 3213# P2 32 psf 4.4 ft 51 ft 7109# P3 -19 psf 4A It 51 ft -4236# P4 12 psf 5.5 ft 51 ft 3366# P5 12 psf 5.5 It 42 ft 2772# TOTAL = 12224# D PRODUCT 207 n Page of Shear Wall Analysis Job : Morts Remodel Architect: Stephen Tapp Job #: T23D1 Date: Au -23 Level: Main Roof Diaphragm Direction: North - South Vseismic @ Level= Vseismic total= Vseismic with redundancy= Total Load to be resolved # = 10260 Grid B C D E Span(FT.) 8.67 25.83 13 Wind load(#/LF) 216 216 216 216 Seismic load(#/LF) 0 0 0 0 0 0 0 0 Load#1 (LB) Load#2(LB) Load#3(LB) P(wind+L1,L2,L3)= 936.36 3726 4193.64 1404 0 0 0 0 P(seismic+L1,L2,L3)= 0 0 0 0 0 0 0 0 Wall Length(FT.) Steel 6 15 23 Unit Shear(#/LF) Frame 621 279.576 61.04348 #DIV/0! #DIV/0! #DIV/0! #DIV/0! Wall Type P1-2" P1-6" P1-6" Area Ab(sq.ft.) shear ratio r= #VALUE! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! Redundancy factor #VALUE! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! Section Length(FT) 4 9.75 6.5 Panel Height(FT) 11 9 9 (M)from upper level 0 0 0 OTM(#') #VALUE! 27324 24532.79 3571.043 #DIV/0! #DIV/0! #DIV/0! #DIV/0! Panel Length(LF) 4 9 17.83 Panel Wt.(#/LF) 200 150 100 Wt. on Panel(#/LF) 150 150 135 Reduction(%) 40 40 40 40 40 40 40 40 RM(#') -1680 -7290 -22412.6 0 0 0 0 Resultant(#') #VALUE! 25644 17591.79 -18841.5 #DIV/0! #DIV/0! #DIV/0! #DIV/0! Uplift @ Panel #VALUE! 6411 1954.644 -1056.73 #DIV/0! #DIV/0! #DIV/0! #DIV/0! Edae(#` -Simpson' crost14 crostc16 n/a Restraint strap strap 1. See building elevations for wind load distribution. 8/7/2023, 12:38 PM Page of Shear Wall Analysis Job : Morts Remodel Architect: Stephen Tapp Job #: T23D1 Date: Au -23 Level: Main Roof Diaphragm Direction: West - East Vseismic @ Level= Vseismic total= Vseismic with redundancy= Total Load to be resolved # = 9435 Grid Span(FT.) Wind load(#/LF) Seismic load(#/LF) Load#l(LB) Load#2(LB) Load#3(LB) P(wind+L1,L2,L3)= P(seismic+L 1, L2, L3)= Wall Length(FT.) Unit Shear(#/LF) Wall Type 1 3 51 185 185 0 0 0 0 0 0 0 0 4717.5 4717.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 21 19.8 224.6429 238.2576 #DIV/O! #DIV/O! #DIV/O! #DIV/01 #DIV/O! #DIV/O! P1-6" P1-6" Area Ab(sq.ft.) shear ratio r= #DIV/O! #DIV/O! #DiV/01 #DIV/O! #DIV/01 #DIV/O! #DIV/O! #DIV/O! Redundancy factor #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! Section Length(FT) 21 12.4 Panel Height(FT) 9 9 (M)from upper level 0 0 OTM(#') 42457.5 26589.55 #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! Panel Length(LF) 21 12.4 Panel Wt.(#/LF) 135 135 Wt. on Panel(#/LF) 135 135 Reduction(%) 40 40 40 40 40 40 40 40 RM(#') -12454.6 0 0 0 0 0 0 Resultant(#') 42457.5 14134.99 #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! Uplift @ Panel 2021.786 1139.918 #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! Edge(#) Simpson' crostc16 crostc16 Restraint strap strap Notes: 1. See building elevations for wind load distribution 8/7/2023, 1:07 PM STEPHEN TAPP ARCHITECT/P.E. 2330 East Madison Street SEATTLE, WA 98112 (206) 320-0534 Morts Remodel SHEET NO. OF CALCULATED BY S l CHECKED BY SCALE DATE DATE 6.26.23 Morts Remodel 1034 B Avenue Edmonds, Washington Wood Beam tapp DESCRIPTION: HDR-100A CODE REFERENCES Project Title: Morts Remodel/Deck Engineer: STT Project ID: Project Descr: remodel kitchen, living and hall areas, build new deck to the west Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-05 Material Properties Analysis Method: Allowable Stress Design Fb + 2,900.0 psi E : Modulus of Elasticity Load Combination: ASCE 7-05 Fb - 2,900.0 psi Ebend- xx 2,200.Oksi Fc - PHI 2,900.0 psi Eminbend - xx 1,118.19ksi Wood Species iLevel Truss Joist Wood Grade Parallam PSL 2.2E Fc - Perp 750.0 psi Fv 290.0 psi Ft 2,025.0psi Density 45.070pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0.2) 8(0.4) I 1)(0.41) S(0.68) I 7x18 i Span = 20.0 ft LL Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.410, S = 0.680, Tributary Width = 1.0 ft Uniform Load : D = 0.20, S = 0.40 , Tributary Width = 1.0 ft DESIGN SUMMARY • Maximum Bending Stress Ratio = 0.841: 1 Maximum Shear Stress Ratio = 0.515 :1 Section used for this span 7x18 Section used for this span 7x18 fb: Actual = 2,682.54 psi fv: Actual = 171.82 psi Pb = 3,188.23psi F'v = 333.50 psi I Load Combination +D+S Load Combination +D+S Location of maximum on span = 10.000ft Location of maximum on span = 0.000 ft 1 Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.523 in Ratio = 459 > 360 Span: 1 : S Only Max Upward Transient Deflection 0 in Ratio = 0 <360 n/a Max Downward Total Deflection 0.818 in Ratio = 293 >=180 Span: 1 : +D+S Max Upward Total Deflection 0 in Ratio = 0 <180 n/a Maximum Forces & Stresses for Load Combinations Load Combination max stress Kauos moment values snear values Segment Length Span # M V CD CM Ct CLx CF Cfu C i Cr M fb Fb V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 20.0 ft 1 0.388 0.238 0.90 1.00 1.00 1.00 0.956 1.00 1.00 1.00 30.50 968.3 2,495.1 5.21 62.0 261.0 +D+S 1.00 1.00 1.00 0.956 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 20.0 ft 1 0.841 0.515 1.15 1.00 1.00 1.00 0.956 1.00 1.00 1.00 84.50 2,682.5 3,188.2 14.43 171.8 333.5 +D+0.750S 1.00 1.00 1.00 0.956 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 20.0 ft 1 0.707 0.433 1.15 1.00 1.00 1.00 0.956 1.00 1.00 1.00 71.00 2,254.0 3,188.2 12.13 144.4 333.5 +0.60D 1.00 1.00 1.00 0.956 1.00 1.00 1.00 0.0 0.00 0.0 0.0 Length = 20.0 ft 1 0.131 0.080 1.60 1.00 1.00 1.00 0.956 1.00 1.00 1.00 18.30 581.0 4,435.8 3.13 37.2 464.0 Morts Remodel 1034 B Avenue Edmonds, Washington Wood Beam DESCRIPTION: HDR-100A Overall Maximum Deflections Project Title: Morts Remodel/Deck Engineer: STT Project ID: Project Descr remodel kitchen, living and hall areas, build new deck to the west Load Combination Span Max."-" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+S 1 0.8176 10.073 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 16.900 16.900 Max Upward from Load Combinations 16.900 16.900 Max Upward from Load Cases 10.800 10.800 D Only 6.100 6.100 +D+S 16.900 16.900 +D+0.750S 14.200 14.200 +0.60D 3.660 3.660 S Only 10.800 10.800 Morts Remodel 1034 B Avenue Edmonds, Washington Wood Beam DESCRIPTION: HDR-100B CODE REFERENCES Project Title: Morts Remodel/Deck Engineer: STT Project ID: Project Descr: remodel kitchen, living and hall areas, build new deck to the west Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-05 Material Properties Analysis Method : Allowable Stress Design Fb + 2,900.0 psi E : Modulus of Elasticity Load Combination: ASCE 7-05 Fb - 2,900.0 psi Ebend- xx 2,200.0ksi Fc - Prll 2,900.0 psi Eminbend - xx 1,118.19ksi Wood Species iLevel Truss Joist Fc - Perp 750.0 psi Wood Grade Parallam PSL 2.2E Fv 290.0 psi Ft 2,025.0 psi Density 45.070pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling MOM lied Loads Beam self weight NOT internally calculated and added Uniform Load : D = 0.10 , Tributary Width = 1.0 ft DESIGN SUMMARY %Maximum Bending Stress Ratio = 0.2241 Section used for this span 7x9.25 ifb: Actual = 601.06psi F'b = 2,686.51 psi Load Combination D Only Location of maximum on span = 10.000ft Span # where maximum occurs = Span # 1 7x9.25 Span = 20.0 ft Service loads entered. Load Factors will be applied for calculations. Maximum Shear Stress Ratio Section used for this span fv: Actual F'v Load Combination Location of maximum on span Span # where maximum occurs Desinn C = 0.082 :1 7x9.25 21.48 psi 261.00 psi D Only 0.000 ft Span # 1 Maximum Deflection Max Downward Transient Deflection 0 in Ratio = 0 <360 n/a Max Upward Transient Deflection 0 in Ratio = 0 <360 rile Max Downward Total Deflection 0.357 in Ratio = 673 -180 Span: 1 : D Only Max Upward Total Deflection 0 in Ratio = 0 <180 n/a Maximum Forces S Stresses for Load Combinations Load Combination max Stress Ratios Moment Values Shear Values Segment Length Span # M V CD CM Ct CLx CF Cfu C i C r M fb F'b V fv F'v D Only 0.0 0.00 0.0 0.0 Length = 20.0 ft 1 0.224 0.082 0.90 1.00 1.00 1.00 1.029 1.00 1.00 1.00 5.00 601.1 2,686.5 0.93 21.5 261.0 +0.60D 1.00 1.00 1.00 1.029 1.00 1,00 1.00 0.0 0.00 0.0 0.0 Length = 20.0 It 1 0.076 0.028 1.60 1.00 1.00 1.00 1.029 1.00 1.00 1.00 3.00 360.6 4,776.0 0.56 12.9 464.0 Overall Maximum Deflections Load Combination Span Max. "-" Deft Location in Span Load Combination Max. "+" Defl Location in Span D Only 1 0.3565 10.073 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from all Load Conditions 1.000 1.000 n Morts Remodel 1034 B Avenue Edmonds, Washington Wood Beam DESCRIPTION: HDR-100B Project Title: Morts Remodel/Deck Engineer: STT Project ID: Project Descr: remodel kitchen, living and hall areas, build new deck to the west Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Max Upward from Load Combinations 0.600 0.600 Max Upward from Load Cases 1.000 1.000 D Only 1.000 1.000 +0.60D 0.600 0.600