Loading...
SEE REV1 BLD2022-1670-APPROVED-Architectural_Plan+2.8.2023_5.47.58_PM+3359897LOT COVERAGE SUMMARY OWNER: Jenni and David Morts PROJECT ADDRESS: 1034 B Avenue S Edmonds, Washington 98020 SNOHOMISH PARCEL NUMBER: 00619400400301 LOT AREA: .17 Acres LEGAL: THE SOUTH 1/2 OF LOT 39 BLOCK 004 YOSTS 1 sT ADDITION QUARTER SECTION T&R NW 25 T27N R 3E Latitude 47.81, Longitude-122.38 PROPERTY USE 111 Single Family Residence GENERAL NOTES & SPECIFICATIONS BUILDING AREA SUMMARY Main Floor Finished Area = 1702 sq ft Lower Floor Finished Area = 754 sq ft Garage = 806 sq ft New Main Finished Area = 107 sq ft Total Main Floor Finished area = 1702 +107 = 1809 sq ft New Exterior Deck = 524 sq ft 1. ALL WORK SHALL COMPLY WITH APPLICABLE CODES, ORDINANCES, AND LAWS. 2. NOTED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AT ALL TIMES. 3. EXTERIOR WALL DIMENSIONS ARE TO FACE OF CONCRETE AND/O!R FACE OF STUD UNLESS OTHERWISE NOTED. 4. ALL CONDUIT AND PIPING SHALL BE CONCEALED, ANY EXPOSED WORK SHALL BE VERIFIED WITH THE ARCHITECT. 5. IN CASE OF ANY CONFLICT WHEREIN THE METHODS OR STANDARDS OF INSTALLATION OR THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ALL CONFLICTS. 6. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION WITH OTHER CONTRACTORS TO SECURE COMIPILIANCE OF DRAWINGS AND SPECIFICATIONS, THE ACCURATE LOCATION OF STRUCTURAL MEMBERS AND OPENINGS FOR MECHANICAL, ELECTRICAL, STAIRS, AND MISCELLANEOUS EQUIPMENT. 7. ALL EXTERRIOR OPENINGS, FLASHINGS, CO'UNTERF'LASHING, EXPANSION JOINTS AND THE LIKE SHALL BE CONSTRUCTED IN SUCH A MANNER AS TO MAKE THEM WEATHERPROOF. 8. VIERIFY ALL VARIATIONS OR DISCREPANCIES WITH THE ARCHITECT PRIOR TO PROCEEDIING WITH THE WORK IN QUESTION, 9. SIERVICE WATER PIPES IN UNHEATED SPACES SHALL BE INSULATED PER WASHINGTONI STATE ENERGY CODE. 10. METAL DUCTS JOINTS SHALL BE TAPED AND INSULATED. 11. OPENINGS TO BE CAULKED, SEALED, OR 'WEATHER-STRIPPED. 12. IBATT INSULATION TEARS AND/OR JOINTS SHALL BE SEALED WITH TAPE.. 13. SHOWERS: FLOW CONTROL LIMITED PER WASHINGTON STATE ENERGY CODE. 14. MOISTURE CONTROL TO BE PROVIDED PER WASHINGTON STATE ENERGY CODE. 15. GROUND COVER WITHIN CRAWL SPACE. COVER WITH MINIMUM 6 MIIL (0.006") BLACK POLYETHYLENE OR EQUIVALENT, LAPPED 12" AT EACH JOINT ANID EXTENDED TO FO'UINDATION WALLS, PER WASHINGTON STATE ENERGY CODE. BUILDING HEIGHT SUMMARY From Survey on Next Page - 4-corners of rectangle = 206.95+213.4+215.7+208.1 = 844.151/4 = 211.04' Maximum Allowable Height = 25' above average grade = 211.04'+25'= 236.04' Actual Height = 232.2' per Survey (shown on elevations) Lot Area =7405 sq ft Allowable lot coverage = 35% =.35*7513 = 2630 sq ft Existing House = 1890 sq ft Existing Exterior Deck/Stairs = 96.5' sq ft New Exterior Deck = 525 sq ft Total proposed Lot Coverage = 2512 sq ft < Allow 2630 sq ft Therefore O.K. 213.4' - - - -lkk--_ - (PER TERR E1 SUR Y 'j 8'-4" 4'-4" e-' �tr 5.5' enclose fover Site Plan 1 If = 10'-0" D-rawing-Index TS- . ITE PLAN/TITLE SHEET SUR-1.0 SURVEY A-1.0 EXISTING MAIN AND LOWER FLOOR PLANS A-2.0 EXISTING BUIDING ELEVATIONS A-3.0 PROPOSED FLOOR PLAN REVSIONS A-4.0 ENERGY SHEET S-1.0 STRUCTURAL NOTES S-2.0 MAIN FLOOR FRAMING/LOWER FLOOR FOUNDATION/LOWER FLOOR SHEAR WALL PLANS S-3.0 MAIN FLOOR SHEAR WALL/ ROOF FRAMING REVISIONS S-4.0 STRUCTURAL DETAILS 0 v WAL,k .� U) w • rCH MARK = W 221.87' TERRAINE SU E 0 5 10 20 GRAPHIC SCALE J M f r r PHRE T eOF"'%T-T'�PP TSNINT�ON revisions 12/1 /22 12/8/22 1 /19/23 1 /23/23 2/8/23 O E M N 0 O °° 17, •� c ■ ♦■■0 C LU W > L V Co c O 0 �w CL CL M Lu f 0 LL M Ln C 01 O p -C U a� o -C�w C) � C) CLL M N 4) A-0 C0 This work was prepared by me or under my supervision. Sheet Contents: Scale: as noted Date: 11 /19/22 Job no.: T22J6 Drawn by: STT Sh o.: TS-1 .0 of 10 LEGAL DESCRIPTION GRAPHIC & BOUNDARY SURVEY PER STATUTORY WARRANTY DEED RECORDING #202108160286 LOT 3 ON BLOCK 4 OF THE PLAT OF YOST'S FIRST ADDITION TO EDMONDS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 8 OF PLATS, PAGE 6, RECORDS OF SNOHOMISH COUNTY, i WASHINGTON; FOUND MON IN CASE i IRON PIPE, DOWN 1.2' EXCEPT THE NORTH 60 FEET THEREOF. (5.56'W & 6.66'S OF CALC'D INTX) SITUATED IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. FOUND MON IN CASE BRASS DISK, DOWN 0.4' BASI OF BEARINGS ►.� (& 2.46'W OFF CCAALC'D INTX) <9 SSMH N 88'45'07" W 329.77' CALC'D (329.93' R1 & R2) FOUND MON IN CASE NAD 83(2011) WASHINGTON NORTH STATE PLANE COORDINATES PER GPS OBSERVATIONS dQ9 RIM=195.94' It It� � -, BRASS DISK, DOWN 0.2' � ►�� `5aq, ,9. �O•. , `��ti IE(W) 8"GONG=189.07' IE(S) 8"CONC=191.34' PINE ST REFERENCES 0 �° �o .. �- SS SS IE(E) 8"CONC=189,56' SS SS SS CB (TYPE 1) SS SS s� ss ss ss - SS - SS SS SS -p - SS SS S R1. RECORD OF SURVEY, AUDITOR'S FILE N0. 9006065002, RIM-200.97' g� ssMH RECORDS OF SNOHOMISH COUNTY, WASHINGTON. IE(W) 8"CPP=199.32' RIM=214.63' R2. SHORT SUBDIVISION, AUDITOR'S FILE NO. 202103305005, N� (IS IE(S) 8"PVC=199.37 IE(W) 8"CONC=208.85' IE(S) 8"CONC=209.32' RECORDS OF SNOHOMISH COUNTY, WASHINGTON. IE(E) 8"CONC=209.67' W VERTICAL DA UM U NAVD 88 PER GPS OBSERVATIONS N SITE TEMP. BENCHMARK o DESCRIPTION: SET PK NAIL W/ RED WASHER LOCATION: SET IN CONC. WALK E OF E PROP LINE n ELEVATION: 221.87' I> w o I CB (TYPE 1) RIM=221.03' SURVEYOR'S NOTE IE(W/E) 12"GONGcn w / 1. THE TOPOGRAPHIC SURVEY SHOWN HEREON WAS PERFORMED IN o ( CB (TYPE 1) � AUGUST OF 2022. THE FIELD DATA WAS COLLECTED AND N o° Sp RIM=222.62' RECORDED ON MAGNETIC MEDIA THROUGH AN ELECTRONIC IE(N) 4"CONC=219.77' (n THEODOLITE. THE DATA FILE IS ARCHIVED ON DISC OR CD. N o FENCE COR STEPS 1.4'N STEPS 1.3'N SOS IE(W) 8"CONC=219.72' w WRITTEN FIELD NOTES MAY NOT EXIST. CONTOURS ARE SHOWN °" o.3'N of OF PROP LINE OF PROP LINE c IE(SE) 4"CONC=220.02' U FOR CONVENIENCE ONLY. DESIGN SHOULD RELY ON SPOT PROP LINE ASPH. I2 _ IE(E) 4"PVC=221.47' 8 0 •- O N ELEVATIONS. o� oti o1 ° ti o (n e FENCE COR 20 3.3'S OF N 8 `44'48" W M _EA ° _ _ 14.7' Y z �� o� �titi e m a. SD Q o 0 Z W (� O 0) 2. ALL MONUMENTS SHOWN HEREON WERE LOCATED DURING THE oti `� ° so PROP LINE ti°6a 24 87 co o ti RAILROAD TIE �o 6 ti �o� tip° `� I' Z o COURSE OF THIS SURVEY UNLESS OTHERWISE NOTED. °� N ° 9 p9 ch m o ml CONC 0.7'S •� ". ° • • W .D STAIRS a • ,�9_ ° ly FENCE COR 0.3'N k. � °. tia° c�� n 0 3. THE TYPES AND LOCATIONS OF ANY UTILITIES SHOWN ON THIS °6°` ° �o AT CQ�1C; ,' ,h CONC 0.7'S n �^ SAVE v`° RAILROAD TIE o BLOC WALL ",�j Q 0 w DRAWING ARE BASED ON INFORMATION PROVIDED TO US, BY cn N FOUND EBAR/CAP ° ° ' e ., °• ° ° o - - ' RO STEPS ti10 � 0 W. co 0 o m m p OTHERS OR GENERAL INFORMATION READILY AVAILABLE IN THE LS# 4 151 ob FOUN EBAR/CAP k �4 co (�, ; d PUBLIC DOMAIN INCLUDING, AS APPLICABLE, IDENTIFYING o 0.10'S FROM PROP COR ., EA LS# 45151 ti° N J W 0 O MARKINGS PLACED BY UTILITY LOCATE SERVICES AND OBSERVED N 42.5' °• • o o5's OF LINE & 'E ', w (� w BY TERRANE IN THE FIELD. AS SUCH, THE UTILITY INFORMATION " '• •' w 6",(2)4"CE > 0, FROM PROP COR , 30' ,', �, p SHOWN ON THESE DRAWINGS ARE FOR INFORMATIONAL N N �• •° %, .•, w 7"cED ROW � � � Q LLl PURPOSES ONLY AND SHOULD NOT BE RELIED ON FOR DESIGN °k . BLDG ° °0 I 4"MAP °: No I "P Q OR CONSTRUCTION PURPOSES; TERRANE IS NOT RESPONSIBLE OR °�41 C, OVERHANG ;° "•' �h O LIABLE FOR THE ACCURACY OR COMPLETENESS OF THIS UTILITY o�.° CONt-�0 I ��Wtiti° io 0 INFORMATION. FOR THE ACCURATE LOCATION AND TYPE OF ° °� .I ;PATIO �� Q P�oOfk k °� .�4 • 0 UTILITIES NECESSARY FOR DESIGN AND CONSTRUCTION, PLEASE •,° �0� F� tit°� 7",6 CED •' ..: .4 CONTACT THE SITE OWNER AND THE LOCAL UTILITY LOCATE Of p • $ O�° 0 o SERVICE (800-424-5555). n c° 6»DEC I o°®� GJ�� G'� Z;ho • ° . „• ° •• °• Z 0 • •• �• 4. SUBJECT PROPERTY TAX PARCEL NO. 00619400400301 J z W a o 11 .r, A CONC••' �`° o - Q 5. SUBJECT PROPERTY AREA PER THIS SURVEY IS 7,512 S.F. r, _ a0 ° ° ^� ° ° Ai�E a O ° • I .• PATIO °, �1 ,\ •EPVE •. & LUM :. °, . ° •° • F- (0.17 ACRES) C w w > M ° • , ' °, .. z e ° G E• '1 �• *r--a,o:- T FFF , eh •� ° J w Q W 3 6. THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE cV ^ I.V �0- `t n •°• °• • ` ° p • "° • '° .• °•.I • �• �� ° &< .e RI�M�2Y7.62°• ^° •, •° '° "� °'" LLJ •" SITE M cwn> m Q Q m N REPORT. EASEMENTS AND OTHER ENCUMBRANCES MAY EXIST o �° ' I O .' •a • °.• • •° ^• °j e •° HOUSE NO. 1034 .� FOOTPRINT-1,600 SF .,° �' 4 '• e� ti' ',° ELEV=:t21.87' m Np N THAT ARE NOT SHOWN HEREON. z .° a , �. • • ° e I• �o,. �� .��9 • ��. • �A. L 7. EXISTING STRUCTURES) LOCATION AND DIMENSIONS ARE 2 ❑ v , •' •• ° .�. '. •• e' .,° colvc,' �° ••°, a I ., ^; CONC •�I °� o titi� ,a�• °� w a MEASURED FROM THE FACE OF THE SIDING UNLESS OTHERWISE � TEL SENTRY a • ' DRgVEWAY• ,°• ••" • ��. STEP z NOTED. "° °" . ° •' •' •• .. ° '• ° ;° "• " '•� L '' I �� • ° , 1� `� ti o �� c, gw tiz 8. FIELD DATA FOR THIS SURVEY WAS OBTAINED BY DIRECT FIELD °.' .9 °•" . ; -A. °`�� w Iw M •, `l' MEASUREMENTS WITH A CALIBRATED ELECTRONIC 5-SECOND cO cn "• ,•° '. •° •• '° '' °; : I,• • W •p p�� TOTAL STATION AND/OR SURVEY GRADE GPS OBSERVATIONS. w cn a• • • • • ��o A. • • • °� "FIR W W W ALL ANGULAR AND LINEAR RELATIONSHIPS ARE ACCURATE AND ••°4, ° • °�"°� ti°k I °° . MEET THE STANDARDS SET BY WAC 332-130-090. ° APPROX. LOCATION a SET ° - - �. 1§ • EAVE ti PER RECORDS (TYP) •.6 LE REBAR/CAP you ° g"FI - o EGEND Z - � ti°b �h 42.9' �x : U, 200 cD 0 6"DEC °, L+J AREA DRAIN (-)SEWER MANHOLE ° - ti I I 0 ASPHALT SURFACE SD STORM DRAIN LINE BENCHMARK TEL SENTRY ❑ TELEPHONE SENTRY ° �� ti h N 8'44'38' 24.87' (125.00' PLAT) l ti N 88'44' 8" W 30.00' FOUND IRON PIPE ® BRICK SURFACE SIZE TYPE O TREE (AS NOTED) BUILDING W WATER LINE m N FENCE COR 1.2'S OF w 0 cn FENCE COR AP X. ON PER i° 0.20'S OF LINE & � 3 (5) J_ CENTERLINE ROW r, WM C WATER METER PROP LINE o PROP LINE MAP NO. 0.39'W FROM PROP COR " coo 2Qn �� ti M CLEANOUT WV WATER VALVE ALL Y o CONCRETE SURFACE BLDG BUILDING ® DECK C.C. CENTER CHANNEL -EJ m o U) o°� THE CLOSEST BUILDING CORNER TO r- �-- X X FENCE LINE (CHAIN LINK) CALC'D CALCULATED THE RIGHT-OF-WAY �- FENCE LINE (WOOD) CB CATCH BASIN a N rn FOR THIS ISPROPERTY G GAS LINE COS CITY OF SEATTLE 20 CONC CONCRETE GUY ANCHOR SD c aJ INLET (TYPE 1) COR CORNER DEC DECIDUOUS o CB (TYPE 1) LUM LUMINAIRE ELEV ELEVATION ® MAILBOX (RESIDENTIAL) m N to RIM=204.83' IE(N) 8"PVC=203.18' (V v o - EVG EVERGREEN 4- ►fit MONUMENT (IN CASE, FOUND) FF FINISH FLOOR IE(E) 4"PVC=203.63' P ❑ POWER METER G GAS IE(S) 8"GONG=203.18' P POWER (OVERHEAD) LS# LAND SURVEYOR NUMBER w rn PP O POWER POLE MEAS MEASURED N v O - PROPERTY LINE (SUBJECT) MON MONUMENT v rn 00 REBAR & CAP (SET) OHP OVERHEAD POWER O REBAR AS NOTED (FOUND) PROP PROPERTY ^ SSMH 00 ROS RECORD OF SURVEY RETAINING WALL Q�'` RIM=206.40' --- Ln v 1- SD SERVICE DRAIN RIGHT-OF-WAY LINES SSMH SANITARY SEWER MANHOLE -EJ ( IE(N/S) =200.13'(C.C.) 8"GONG ROCKERY SF SQUARE FEET ,gyp N CD a)N SS SEWER LINE HX HEAT EXCHANGER cpp'` �,9, � s9,9. � m Q VICINITY MAPJ °SS t�1 N.T.S. FOUND MON IN CASE FIR S T JOB NUMBER: 221319 DATE: 08/18/22 Pine St TACK/LEAD, DOWN 0.9' N 88'44'19" W 329.73' MEAS. (329.79 R1 & R2) DRAFTED BY., TDB > = D Pine Street < > < FOUND MON IN CASE CHECKED BY: KOP/CSP Playfield W Q BRASS DISK, DOWN 0.4' SCALE: ill = 10' Hk En REVISION HISTORY > "e npo' ncare and Waxing STEEP SLOPE/BUFFER DISCLAIMER: THE LOCATION AND EXTENT of STEEP SLOPES SHOWN ON THIS DRAWING ARE FOR INDEXING INFORMATION INFORMATIONAL PURPOSES ONLY AND CANNOT BE RELIED ON FOR DESIGN AND/OR SE 1/4 NW 1/4 CONSTRUCTION. THE PITCH, LOCATION, AND EXTENT ARE BASED SOLELY ON OUR 4 4 GENERAL OBSERVATIONS ON SITE AND OUR CURSORY REVIEW OF READILY AVAILABLE SITE NW NE SECTION: 25 10 0 5 10 PUBLIC DOCUMENTS; AS SUCH, TERRANE CANNOT BE LIABLE OR RESPONSIBLE FOR D Fir St > Fir St THE ACCURACY OR COMPLETENESS OF ANY STEEP SLOPE INFORMATION. ULTIMATELY, TOWNSHIP: 27N THE LIMITS AND EXTENT OF ANY STEEP SLOPES ASSOCIATED WITH ANY SETBACKS OR SHEET NUMBER °' D SW 4 SE 4 RANGE: 03E, W.M. ( IN FEET) OTHER DESIGN OR CONSTRUCTION PARAMETERS MUST BE DISCUSSED AND APPROVED BY THE REVIEWING AGENCY BEFORE ANY CONSTRUCTION CAN OCCUR. 1 OF 1 D COUNTY: SNOHOMISH 1 INCH = 10 FT. Existing Lower Floor Plan 1/4" = 1'-0" ,-----------------------�, I� /I Ll/--------------------- - LIVING AREA 1554 5a FT Existing Main Floor Plan with Roof Outline 1 /4" = 1'-0" 5� �STERE� r I C;HITE I. RHE ± T. TAPP 1E OF ASMCTnN revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 O E .M o 00 ■ 4■■+ C lLl M Qz Z M W L � 5 z �a CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT M W -) C M _O Cf) C S \ O O S; U M C, 6 cn L M N This work was prepared by me or under my supervision. Sheet Contents: Scale: as noted Date: 11 /9/22 Job no.: T22J6 Drawn by: STT Sheet no.: A-1.0 of 10 M um Roof Height (see TP-1) Existing South Elevation - with additions 1 /4" = 1'-0" basement beyond Existing East Elevation - with additions 1 /4" = 1'-0" 236.04' Roof Heig 232.2' Ex. Main FI'r 218.4' Grade .9' Existing Roof Height(per ------------ Ex.Main FI'r Average Grade 211.9' urvey) let, 17L0l9.11l6 0]1�Y1 Existing West Elevation - with additions 1 /4" = 1'-0" Existing North Elevation - with additions 1 /4" = 1'-0" � r 595 R kTERE�j QH(TE T TE OFPHEAswTON revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 O E o O00 00 ■ — 4a o o� W az� Z� LU >� 0 t�mq O o O rw RESUB Feb 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT M W N C LS) C F U M 6 CD N N L LT a) V a O in L M N This work was prepared by me or under my supervision. Sheet Contents: Scale: as noted Date: 11 /9/22 Job no.: T22J6 Drawn by: STT Sheet no.: A-2.0 of 10 2018 Washington State Energy Code - Residential 2018 Washington State Energy Code - Residential Prescriptive Energy Cade Compliance for AJI Climate Zones in Washineton Single Fa milv - New & Additions (effective February 1. 20211 These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings (townhouses). Project information Contact lnjormatiaa Morts Remodel David Morts ! Stephen Tapp ArchitecbV.E. 1034 B Ave S, Edmonds, WA 206-669-2255 1 206-459-5151 Instructions: This single-family project wiII use the requirements of the Prescriptive Path below and incorporate the minirnum values listed. Based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant, Provide all information from the following tables as buiIdiing permit drawings: Table R402.1- Insulation and Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. ALPthorized Representative 20Date 1 112123 AI I Clim ate Zan es (Ta ble R402 A A) R-Value U-Factor Fenestration U-Factor ° n/a 0.30 Skylight U-Factore n/a 0.50 Glazed Fenestration SHGC hr° n/a n/a Ceiling a 49 0.026 Woad Frame wall &h 21 int 0.056 Floor 30 0.029 Below Grade Wall .h 10/15/21 int + TB 0.042 Slab'"R-Value & Depth 10, 2 ft n/a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less a than the label or design thickness of the insulation, the compressed R-value Df the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table_ b The fenestration U-factor column excludes skylights. "10/15/21 +5T0" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement waIL "10/15/21 +5TB" shah be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exteriDr of the wall. "5TB" means R-5 thermal break between floor slab and basement wall_ d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1_ e For single rafter- or joist -vaulted ceilings the insulation may be reduced to R-38 if thefull insulation depth extends over the top plate Df the exterior wall_ R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protectingfoam plastics. For lag structures developed in rompliance with Standard ICC 400r log walls shall meet the requirements for 8 dimate zone 5 of ICC 400. Int_ (intermediate framing) denotes framing and insulation as described in Section AlD3.2.2 including standard h framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10 in sulation. Prescriptive Palh- Single Fatuity 2018 Washinglon State Energy Code-R 1 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Table 406.3 - Energy Credits (Single Family) Option Description 2. AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION OPTIONS Only one option from Items 2.1 through 2.4 may be selected in this category. Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall 2.1 be met with a high efficiency fan(s) (maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present). Ventilation systems using a furnace including an ECM motor are allowed, provided that they are controlled to operate at low speed in ventilation only mode. Credits: SF To qualify to claim this credit, the building permit drawings shall specify the option being selected and the maximum tested building air leakage, and shall show the qualifying ventilation system and its control sequence of operation. Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested 2.2 air leakage to 0.25 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.65. 1 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested 2.3 air leakage to 0.25 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.75. 1 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.6 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested 2.4 air leakage to 0.15 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.80. Duct installation shall comply with Section R403.3.7. 1 1 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilation system. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 0.5 1.0 1.5 2.0 5 Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: 6 credits All dwelling units that are not included in #1 or #3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R406.2 and 406.3 Heating Options Fuel Normalization Descriptions Credits - select ONE heating option User Notes 1 Combustion heating minimum NAECAb 0.0 ❑ 2 Heat pump` 1.0 3 Electric resistance heat only - furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 ❑ 5 All other heating systems -1.0 ❑ Energy Credits - select ONE Options p Energy Credit Option Descriptions energy option from each category 1.1 Efficient Building Envelope 0.5 ❑ 1.2 Efficient Building Envelope 1.0 ❑ 1.3 Efficient Building Envelope 0.5 ❑ 1.4 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑ 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Air Leakage Control and Efficient Ventilation 2.0 ❑ 3.11 High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC 1.0 ❑ 3.3' High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 x❑ 3.5 High Efficiency HVAC 1.5 ❑ 3.6a High Efficiency HVAC ❑ 2.0 ❑ 4.1 High Efficiency HVAC Distribution System 0.5 ❑ L 4.2 High Efficiency HVAC Distribution System ❑ 1.0 ❑ Prescriptive Path - Single Family 2018 Washington State Energy Code-R 2 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Table 406.3 - Energy Credits (Single Family) Option Description Credits: SF 5. EFFICIENT WATER HEATING OPTIONS Only one option from Items 5.2 through 5.6 may be selected in this category. Item 5.1 may be combined with any option. A drain water heat recovery unit(s) shall be installed, which captures waste water heat from all and only the showers, and has a minimum efficiency of 40% if installed for equal flow or a minimum efficiency of 54% if installed for unequal flow. Such units shall be rated in accordance with CSA B55.1 or IAPMO IGC 346-2017 and be so labeled. 5.1 0.5 To qualify to claim this credit, the building permit drawings shall include a plumbing diagram that specifies the drain water heat recovery units and the plumbing layout needed to install it. Labels or other documentation shall be provided that demonstrates that the unit complies with the standard. Water heating system shall include one of the following: 5.2 0.5 Energy Star rated gas or propane water heater with a minimum UEF of 0.80. s Water heating system shall include one of the following: Energy Star rated gas or propane water heater with a minimum UEF of 0.91 or Solar water heating supplementing a minimum standard water heater. Solar water heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification Corporation (SRCC) Annual Performance of OG-300 Certified Solar Water Heating 5.3 Systems or 1.0 Water heater heated by ground source heat pump meeting requirements of Option 3.3. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency and, for solar water heating systems, the calculation of minimum energy savings. Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier I of NEEA's advanced water heating specification or 5.4 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier I of 1.5 NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. s Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier III of NEEA's advanced water heating specification or 5.5 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of 2.0 NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. s Water heating system shall include one of the following: Electric heat pump water heater with a minimum UEF of 2.9 and utilizing a split system configuration with the air -to -refrigerant heat exchanger located outdoors. Equipment shall meet Section 4, requirements for all units, of the NEEA standard Advanced Water Heating Specification with the UEF noted above or 5.6 2.5 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of NEEA's advanced water heating specification and utilizing a split system configuration with the air -to -refrigerant heat exchanger located outdoors, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. s s To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 7 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Summary of Table R406.2 (cont.) Energy Credits - select ONE Energy Credit Option Descriptions (cont.) Options energy option from User Notes d each category 5.1d Efficient Water Heating 0.5 ❑ 5.2 Efficient Water Heating 0.5 ❑ 5.3 Efficient Water Heating 1.0 l� 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating 2.0 ❑ 5.6 Efficient Water Heating 2.5 ❑ 6. le Renewable Electric Energy (3 credits max) 1.0 0 7.1 Appliance Package 0.5 ElTotal Credits 2.5 Calculate Total Clear orm a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category S. Option 5.1 may be combined with options 5.2 through 5.6. See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Please print only pages 1 through 3 of this worksheet for submission to your building official. For Building Officials Only Prescriptive Path - Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Table 406.3 - Energy Credits (Single Family) Option Description Credits: SF 3. HIGH EFFICIENCY HVAC EQUIPMENT OPTIONS Only one option from Items 3.1 through 3.6 may be selected in this category. z Energy Star rated (U.S. North) Gas or propane furnace with minimum AFUE of 95% or 3.1 Energy Star rated (U.S. North) Gas or propane boiler with minimum AFUE of 90%. z 1.0 3.2 Z Air -source centrally ducted heat pump with minimum HSPF of 9.5. 3 1.0 Closed -loop ground source heat pump; with a minimum COP of 3.3 or 3.32 Open loop water source heat pump with a maximum pumping hydraulic head of 150 feet 1.5 and minimum COP of 3.6. 3 Ductless mini -split heat pump system, zonal control: In homes where the primary space 3.4 heating system is zonal electric heating, a ductless mini -split heat pump system with a 1.5 minimum HSPF of 10.0 shall be installed and provide heating to the largest zone of the housing unit. 4 3.5 2 Air -source, centrally ducted heat pump with minimum HSPF of 11.0. 4 1.5 Ductless split system heat pumps with no electric resistance heating in the primary living areas. A ductless heat pump system with a minimum HSPF of 10 shall be sized and installed to provide heat to entire dwelling unit at the design outdoor air temperature. 3.6 z 2.0 To qualify to claim this credit, the building permit drawings shall specify the option being selected, the heated floor area calculation, the heating equipment type(s), the minimum equipment efficiency, and total installed heat capacity (by equipment type). z An alternative heating source sized at a maximum of 0.5 W/sf(eq uiva lent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. 3 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 4 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 4. HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM OPTIONS All supply and return ducts located in an unconditioned attic shall be deeply buried in ceiling insulation in accordance with Section R403.3.7. For mechanical equipment located outside the conditioned space, a maximum of 10 linear feet of return duct and 5 linear feet of supply duct connections to the equipment may be outside the deeply buried insulation. All metallic ducts located outside the conditioned 4.1 space must have both transverse and longitudinal joints sealed with mastic. If flex ducts 0.5 are used, they cannot contain splices. Duct leakage shall be limited to 3 cfm per 100 square feet of conditioned floor area. Air handler(s) shall be located within the conditioned space. HVAC equipment and associated duct system(s) installation shall comply with the requirements of Section R403.3.7. Locating system components in conditioned crawl spaces is not permitted under this option. 4.2 Electric resistance heat and ductless heat pumps are not permitted under this option. 1.0 Direct combustion heating equipment with AFUE less than 80% is not permitted under this option. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and shall show the location of the heating and cooling equipment and all the ductwork. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 3 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Table 406.3 - Energy Credits (Single Family) Option Description Credits: SF 1. EFFICIENT BUILDING ENVELOPE OPTIONS Only one option from Items 1.1 through 1.7 may be selected in this category. Compliance with the conductive UA targets is demonstrated using Section R402.1.4, Total UA alternative, where [1- (Proposed UA/Target UA)] > the required %UA reduction. Prescriptive compliance is based on Table R402.1.1 with the following modifications: 1.1 Vertical fenestration U = 0.24 0.5 Prescriptive compliance is based on Table R402.1.1 with the following modifications: 1.2 1.0 Vertical fenestration U = 0.20 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.28 Floor R-38 1.3 Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and 0.5 under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.25 Wall R-21 plus R-4 ci Floor R-38 1.4 Basement wall R-21 int plus R-5 ci 1.0 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 15% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.22 Ceiling and single -rafter orjoist-vaulted R-49 advanced Wood frame wall R-21 int plus R-12 ci Floor R-38 1.5 Basement wall R-21 int plus R-12 ci 2.0 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 30% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.18 Ceiling and single -rafter orjoist-vaulted R-60 advanced Wood frame wall R-21 int plus R-16 ci 1.6 Floor R-48 3.0 Basement wall R-21 int plus R-16 ci Slab on grade R-20 perimeter and under entire slab Below grade slab R-20 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 40%. Advanced framing and raised heel trusses or rafters Vertical Glazing U-0.28 1.7 R-49 Advanced (U-0.020) as listed in Section A102.2.1, Ceilings below a vented attic and 0.5 R-49 vaulted ceilings with full height of uncompressed insulation extending over the wall top plate at the eaves. Prescriptive Path - Single Family 2018 Washington State Energy Code-R 4 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Table 406.3 - Energy Credits (Single Family) Option Description 6. RENEWABLE ELECTRIC ENERGY OPTION For each 1200 kWh of electrical generation per housing unit provided annually by on -site wind or solar equipment a 1.0 credit shall be allowed, up to 3 credits. Generation shall be calculated as follows: For solar electric systems, the design shall be demonstrated to meet this requirement using the National Renewable Energy Laboratory calculator PVWATTs or approved alternate by the code official. 6.1 Documentation noting solar access shall be included on the plans. For wind generation projects designs shall document annual power generation based on the following factors: the wind turbine power curve; average annual wind speed at the site; frequency distribution of the wind speed at the site and height of the tower. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall show the photovoltaic or wind turbine equipment type, provide documentation of solar and wind access, and include a calculation of the minimum annual energy power production. 7. APPLIANCE PACKAGE OPTION All of the following appliances shall be new and installed in the dwelling unit and shall meet the following standards: Dishwasher - Energy Star rated Refrigerator (if provided) - Energy Star rated Washing machine - Energy Star rated 7.1 Dryer- Energy Star rated, ventless dryer with minimum CEF rating of 5.2 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall show the appliance type and provide documentation of Energy Star compliance. At the time of inspection, all appliances shall be installed and connected to utilities. Dryer ducts and exterior dryer vent caps are not permitted to be installed in the dwelling unit. Credits: SF 1.0 0.5 �T�RED ME V :PHEM T. TAPP OF _ ASMNaTnN lr-- ___" t17 r f if-+ I-Ir revisions 2/8/23 01 M ■� }� O N O CD O 00 0 ■� �_ O U ■ 15 N S W aZz� lotS= LU > O 0 W RESUB Feb 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT M UJ C co O Ln o o .S C' U) L U co C' Q) s � � CD N N s `U m C:, U o_ o cn L M N Cn This work was prepared by me or under my supervision. Sheet Contents: Scale: as noted Date: 1.23.23 T22J6 Job no.: Drawn by: STT Sheet no.: A-4.0 of 10 MY1.3 CEILINGS: (VAULTED -SINGLE RAFTER) R-38 WALLS ABOVE GRADE: R-21 int. WALLS BELOW GRADE: (INTERIOR) R-10/15/21 int. + TB FLOORS: R-30 SLAB ON GRADE: ( MINIMUM 24" WIDE) R-10 REC ROOMI ' � II A-3 I I I ----------------------- I I I I I I I I I ,III I , r _ _ _ h ---- Iri► _ f _ _� J 11 _ 1 a w - • _ _ � I _ _ r' arm • - n Prawn16.%.FVV%ff1 1 c e� 1/4��-__ -,0��-_-_„----- 79 ---- ---------"----------� y existing 9070 o.h.dr. BATH W15 W14 existing 907( r I ENERGY CODE SUMMARY IN CONST CTION) AN ffl1f ED N 2018 W SHINGTON STATE ENERGY CODIAL ROVIS NS, CHAPTERS 1 THRU 5 FOR RESIDENTIAL OCC C : TABLE R301.1, CLIMATE ZONE 4C, AND TABLE R402.1.1 - HEATING BY OTHER FUELS). PERCENTAGE OF GLAZING TO I TOTAL FLOOR AREA: UNLIMITED MAXIMUM GLAZING U-VALUE: (VERTICAL) •28 MAXIMUM GLAZING U-VALUE: (OVERHEAD) .50 BONUS MAXIMUM DI BLE R303.1.3(1) .20 ROOM MINIMUM REVUIRED INSULATION VALUES CEILINGS: f R-49 CEILINGS: (VAULTED -SINGLE RAFTER) R-38 I WALLS ABOVE GRADE: R-21 int. WALLSS BELOW GRADE: (INTERIOR) R-10/15/21 i int. + TB FLOORS: R-30 SLAB ON GRADE: ( MINIMUM 24" WIDE) R-10 WINDOW 56HEDULE NUMBER LABEL COMMENTS OTY FLOOR SIZE R/O EGRESS DESCRIPTION HEADER MANU GTURER U-FACTOR 1N01 1065FX ENTRY WAY 1 1 1065FX 13 3/8"X80 1/2" FIXED 6LA55 2X6X16 3/5" (2) UNKN INN----- W02 51034L5 GUEST BEDROOM - FRONT 1 1 51034L5 11"X41" LEFT SLIDING 2XSX14" (2) MILGARD 0.28 W03 21034L5 GUEST BEDROOM - BAGK 1 1 21034L5 35"X41" LEFT SLIDING 2X6X38" (2) MILGARD 0.28 1N04 24211 L5 GUEST BATH 1 1 24211 L5 2q"X35 1/2" LEFT SLIDING 2X6X32" (2) MILGARD 0.5 W05 W05-20061 LIVING ROOM SLIDER 1 11 20061 L/R EX 242"X81 15/16" YES EXT. QUAD SLIDER -GLASS PANEL 2X12X245" (2) FLEETWOOD 0.4 W06 156q SUNROOM SLIDER 1 11 156q L EX q1 "X84" YES EXT. SLIDER -GLASS PANEL 2X10Xg4" (2) MILGARD 0.4 1N07 WO1-14105gFX SUNROOM 1N. FACING 1 1 14105gFX 11q"X101, FIXED 6LA55 2X12X182" (2) FLEETWOOD 0.55 WOS 155gFX SUNROOM N. FACING 1 1 155gFX q0"X10" FIXED GLASS 2X10Xg3" (2) FLEETWOOD 0.33 1N0q 5434L5 KITCHEN 1 1 5434L5 65"X41" LEFT SLIDING 2XSX68" (2) MILGARD 0.28 1N10 5032L5 PRIMARY BATH 1 1 5032L5 61"X3q" LEFT SLIDING 2XSX64" (2) MILGARD 0.28 1N11 210515H PRIMARY BEDROOM - BACK 1 1 210515H 35"X62" SINGLE HUNG 2X6X3Y (2) 0.28 W12 51135L5 PRIMARY BEDROOM - FRONT 1 1 151135LS 11 1/2"X41 1/2" LEFT SLIDING 2XSX14 1/2" (2) MILGARD 0.28 1N13 6054LS GARAGE 1 0 6054LS 1311X4111 LEFT SLIDING 2X1OX16" (2) MILGARD 0.28 1N14 6068 BASEMENT LIVING RM SLIDER 1 0 6068 L EX 14"X83" YES EXT. SLIDER-GLA55 PANEL 2X1OX11" (2) MILGARD 0.28 W15 51031 OL5 BASEMENT LIVING RM 1 0 51031 OL5 11 "X47 LEFT SLIDING 2XSX14" (2) MILGARD 0.28 1N16 21034LS BASEMENT GUEST BATH 3 1 0 21034LS 35"X41" LEFT SLIDING 2X6X38" (2) MILGARD 0.5 1N17 21034L5 BASEMENT GUEST BED 3 1 0 21034L5 34 1/8"X41" LEFT SLIDING 2X6X31 1/8" (2) MILGARD 0.28 W18 21034L5 BASEMENT GUEST BED 4 1 0 21034L5 34 1/8"X41" LEFT SLIDING 2X6X31 1/8" (2) MILGARD 0.28 WINDOW 56HEDULE NUMBER LABEL COMMENTS aTY FLOOR SIZE R/O EGRESS DESCRIPTION HEADER MANUFACTURER U-FACTOR W01 1065FX ENTRY WAY 1 1 1065FX 13 3/8"X80 1/2" FIXED GLASS 2X6X16 3/8" (2) UNKNOWN 0.3 W02 51034L5 GUEST BEDROOM - FRONT 1 1 51034L5 11"X41" LEFT 5LIDING 2X5X14" (2) MILGARD 0.25 W03 21034L5 GUEST BEDROOM - BACK 1 1 21034L5 35"X41" LEFT SLIDING 2X6X38" (2) MILGARD 0.28 W04 24211 L5 GUEST BATH 1 1 24211 L5 2q"X35 1/2" LEFT SLIDING 2X6X32" (2) MILGARD 0.3 W05 W05-20061 LIVING ROOM SLIDER 1 11 20061 L/R EX 242"X81 15/16" YES EXT. QUAD SLIDER -GLASS PANEL 2X12X245" (2) FLEETWOOD 0.4 W06 156q SUNROOM SLIDER 1 1 156q L EX q1"X84" YES EXT. SLIDER -GLASS PANEL 2X10Xg4" (2) MILGARD 0.4 WO1 WO1-14105gFX SUNROOM W. FACING 1 1 14105gFX 11q,,X10,, FIXED GLASS 2X12X182" (2) FLEETWOOD 0.33 WOS 155gFX 5UNROOM N. FACING 1 1 155gFX q0"X10" FIXED GLA55 2X10Xg3" (2) FLEETWOOD 0.33 WOq 5434L5 KITCHEN 1 1 5434L5 65"X41" LEFT SLIDING 2XSX68" (2) MILGARD 0.28 W10 5032LS PRIMARY BATH 1 11 5032LS 61,,X3q, LEFT SLIDING 2X8X64" (2) MILGARD 0.25 W11 210515H PRIMARY BEDROOM - BACK 1 1 210515H 35"X62" SINGLE HUNG 2X6X38" (2) 0.25 W12 51135L5 PRIMARY BEDROOM - FRONT 1 1 51135L5 11 1/2"X41 1/2" LEFT SLIDING 2XSX14 1/2" (2) MILGARD 0.28 W13 6034L5 GARAGE 1 0 6034L5 13"X4111 LEFT SLIDING 2X10X16" (2) MILGARD 0.28 W14 6068 BASEMENT LIVING RM SLIDER 1 0 6066 L EX 14"X83" YES EXT. 5LIDER-GLA55 PANEL 2X10X17 (2) MILGARD 0.25 W15 51031OL5 BASEMENT LIVING RM 1 0 51031OL5 11"X47 LEFT SLIDING 2XSX14" (2) MILGARD 0.25 W16 121034LS IBASEMENT GUEST BATH 3 1 10 121034LS 35"X41" ILEFT SLIDING 2X6X38" (2) IMILGARD 0.3 W11 121034L5 JBA5EMENT GUEST BED 3 1 10 121054L5 134 1/8"X41" ILEFT 5LIDING 2X6X31 1/8" (2) MILGARD 0.25 W18 121034LS IBASEMENT GUEST BED 4 1 10 121034LS 134 1/8"X41" ILEFT SLIDING 2X6X31 11Y (2) MILGARD 0.25 W. new 42" high guard rail NEW DECK 5/4 wood decking BATH/LAUNDRY W4 --F--T- W3 lowed to be connected wirelessly, floor plans. TING zoom 2868 ALL =0 11,= - - - - - - - - - - - m 0 a CL ON LOSET I GL05ET I� T-0" X T-F F YER ^ I 3068 W 1 - - - - - - - - - PORGH 14'-1 11 X 4'-311 Proposed Main Floor Plan 1/4" = 1'-0" Wall Schedule steel frame columns RE -BUILT SITTING --T---- - ----T- _ 14968� - L # O 100 cfm ex fan N m N S.D.;CO2 i 5.13.?G02 KITCHEN 100 cfm ex fan EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED NEW WALL eS[%i] EXISTING BEDROOM 1 A 595R +TER€a PHITE I PHEN T. TAPP T TE OF �VASI�UNGXON revisions 1- 1 /22 'V' AV22 2, 3, 23 Thi: me Shee . W18 ScalE Job D� of 10 RESUB Feb 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 94133 Mid Rail 95,50f,13 in [2426 mm] 3.88 in 94012 Top Rail 94252 Baluster [98 mml� c an. 17 in rnd]6 ml A ii_R1 f_n6 in fRSQ mml� 42.t [101 MA) F A - —94252 Baluster 5.56t.06 in [141 mm] D I C �L 0 in 7 mm] 32.25 in [819 mm] LL- E -94013 Bottom Rail2.00 inJ!3: [51 mm] m] 95.50+.13 in [2426 mm] �� 3.88 in 3.69 in [98 mm] [94 mm] Centered between support posts 96.00 in MAX 4.00— in [101.&- mm] i[4sa mm] Figure 2 Westbury' Riviera Series Style C30 Aluminum Railing System 4.00-w in [101.6iU5 mm] .125— in 13.210.4 mm] Figure 22 - 4x4 Aluminum Post Assembly AF- Post must be set to have screw line perpendicular with rail line. 2.00 in O (3) C 10 150.8 mm] 2.00 in —$— -- Railing E [50.8 mm] -- i OU (4) UC VIEW A -A SCALE .75 1/4" X 1/4" +/- 1/16" 10898 Leveling Bolt 1/4"x'/4" ±1116" Welded all 4 sides full length to plate with 3/64" ER 5356 wire 37" [940 mm] 74021 Post (36" [914 mm] Guardrail) 43" [1092 mm] 74023 Post (42" [1067 mm] Guardrail) Tolerance = t 1/16" 3.88 in 55236 Leveling [98.4 mm] Shim Plate 55258 #14 SS Screws (2 req.) Figure 23 — 2" Aluminum Support Post Assembly RAILING DETAIL NTS ne/End Post 1016 1018 rossover Post: I 1020 1021 Simpson top flange hanger HB5.5/16 Simpson top flange hanger HB5.5/18 -- line of deck a DB-100 — — — — — — — — — — — — — — �— — — — — — — — — — — — — — — — rL�1 1 � � I I \ D/,i100 I DJ-101 I' A\ 10 `'r' Q 0 p S-4.0 co m i o CD DS-100 \ m II Q I I .�';\ - -- - - ---- - - - - -- II I I II crostcl 6 \ /' 1I114" tension straps on \ I underside of deck joists , `\ I II \ I o„ 256 1 /4" n � I O � Simpson top flange hanger HB5.5/16 DC-100 with Simpson 'MPB66Z' embedded post base with CCQ5-6SDS2.5 column cap - typical 3 places RFC-100 i1.3 16 , P5 cosyI \`\ DB-106 ` 10B" 12 108.. 2" ' \� -- DL_ —--- ---4' I� I; I' DC-100 wl �S column cap y 45 1/2" I. ' T 33 3l4" 4" HDU5 holdown w/dbl studs s6rrABtMZ po-sttase with-Ge 5-6-SDS2:5 II 3 places CONTINUOUS FOOTING 30" wide x 16" thick continuous footing with 444 longitudinal and #3 ties (@ 12" o.c RFC-100 CnW X W � P1411111 epo y grout 2-#4 horizontal bars into existing foundation VHDU5holdo wn w/dbl studs 1n SLAB TO BE INSULATED AROUND NTI PERIMETER WITH R-10 RIGID INSULATION AS ELL AS BELOW ENTIRE NEW SLAB �I 5 I� .I epoxy grout 244 horizontal bars into existing foundation �I al I .I I I� L — — — — — — — — — — — — — — — — — J — — — — — — — — — — — — — — — — — — — - 111211111111111111 UP epoxy grout 244 horizontal bars into existing foundation 61 Beam Schedule DB-100 P.T. 2 1/2 x 18 24FV4 GLB DB-101 P.T.5 1/8 X 18 24FV4 GLB/OR/ W8X48 STEEL BEAM DB-102 not used DB-103 P.T.5 1/8 X 16 1/2 24FV4 GLB DB-104 HSS 8X4X5/8 STEEL TUBE DB-105 DBL EXISTING JOISTS DB-106 P.T. 4X10 DF#1 DC-100 P.T.6X6 DF#1 POST DJ-100 P.T. 6X6 DF#1 @ 12" O.C. DJ-101 P.T. 2x10 DF#1 @ 16" O.C. DL-100 P.T. 2x10 DF#1 LEDGER W/ 2 ROWS 5/8"d. LAG BOLTS @18" O.C. DS-100 P.T. 6X6 DF#1 FRB-100 HSS 8X4X5/8 STEEL TUBE RFC-100 HSS6X5X1/2 STEEL TUBE All new beams and headers to be 4x10 DF#1 unless noted otherwise in the framing plans\ P.T. means pressure treated SHEAR WALL NOTES - FOUNDATION INDICATES'SIMPSON' HOLDOWN LOCATION (SEE C MANUFACTURER'S INSTALLATION REQUIREMENTS). HOLDOWN ANCHORS ARE TO BE INSTALLED AT THE END OF PLYWOOD SHEAR WALL PANELS. SEE SHEAR WALL SCHEDULE FOR SHEAR WALL NOTES, SCHEDULES, ANCHOR BOLT PLACEMENT, AND PRESSURE TREATED SILL SIZES. ALL SHEAR WALL PANELS OTHER THAN P1-6" ARE TO BE INSTALLED WITH PRESSURE TREATED 3X SILLS. ANCHOR BOLTS TO BE MINIMUM 5/8"0 X 10" @ 48" O.C. (UNLESS NOTED OTHERWISE IN ANCHOR BOLT SCHEDULE, SHEET S-3). CONCRETE STRENGTH F'C = 3000 PSI FOR CONCRETE EXPOSED TO THE ELEMENTS. CONCRETE STRENGTH F"C = 2500 PSI FOR CONCRETE NOT EXPOSED TO ELEMENTS. NOTIFY ENGINEER OF ANY REVISIONS TO SHEAR WALL OR HOLDOWN PLAN OR FIELD MODIFICATIONS DUE TO UNFORESEEN CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION. INCREASE DEPTH OF FOUNDATION AT HOLDOWN ANCHOR BOLTS TO INSURE PROPER CONCRETE COVERAGE. SIMPSON STRONG TIE CONNECTORS ARE SPECIFICALLY REQUIRED TO MEET THE STRUCTURAL CALCULATIONS OF THIS PLAN. BEFORE SUBSTITUTING ANOTHER BRAND, CONFIRM LOAD CAPACITY BASED ON RELIABLE PUBLISHED TESTING DATA OF CALCULATIONS. THE ENGINEER OF RECORD SHOULD EVALUATE AND GIVE APPROVAL FOR SUBSTITUTION PRIOR TO INSTALLATION. Slab on grade 4"thk concrete slab with 6"x6"xW2.9xW2.9 W on 6 mil vapor barrier I epoxy grout 244 horizontal 6" compacted fill 12 I I bars into existing foundation -4.0 , --------------- I E (C A)n 11 -941/2" 1 21T Deck Framing Plan/Partial Lower Floor SW Plan 1/4" = 1'-0" SHEAR WALL NOTES - WALLS PX-X INDICATES SHEAR WALL. SEE LEGEND. SEE SHEAR WALL SCHEDULE FOR SHEAR WALL NOTES, ANCHOR BOLT PLACEMENT, PRESSURE TREATED SILL SIZES, AND INSTALLATION DETAILS. NOTIFY ENGINEER OF ANY REVISIONS TO SHEAR WALL OR FIELD MODIFICATIONS DUE TO UNFORESEEN CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION. DIAPHRAGM SHEATHING NAILS SHALL BE DRIVEN SO THAT THEIR HEAD OR CROWN IS FLUSH WITH THE SURFACE OF THE SHEATHING. THE FASTENERS USED IN THE SHEAR WALL DESIGN ARE 10d COMMONS OR 10d GALVANIZED BOX NAILS. ANY FASTENER SUBSTITUTION WILL HAVE TO BE REVIEWED BY ENGINEER PRIOR TO CONSTRUCTION. SOLID BLOCK BELOW SHEAR WALLS ABOVE. INDICATES SHEAR WALL TIE DOWN STRAP BETWEEN THE SHEAR WALL ABOVE AND THE FRAMING ABOVE OR THE WALLS BELOW. revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 O E +� o o CD O00 �+ LU aZz� w tea= i O � t0 o W RESUB Feb 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT M W C co (� _O U C O O -S; U M ^, 6 s C-`U U a o Cn L co N Cn This work was prepared by me or under my supervision. Sheet Contents: Scale: as noted Date: 11 /9/22 Job no.: T22J6 Drawn by: STT Sheet no.: S-2.0 _r w n O � NEW ROOF STRUCTURE Roof Framing Plan/Main Floor SW Plan 1/4" = 1'-0" r 6 O E49 0 Beam Schedule FRB-100 HSS8X4X5/8 STEEL TUBE DR-100 3 1/2 x 14 2.0E PSL 100 5 1/8 X 12 24FV4 GLB 101 4X8 DF#1 102 3 1/2 X 9 24FV4 GLB 103 3 1/2 X 10 1/2 24FV4 GLB C-100 HSS6X5X1/2 STEEL TUBE -100 2 X 12 DF#1 -100 2X8 DF#1 @ 24" O.C. �I[IIIy�'(I[17�]�e�ll ,II new beams and headers to be 410 DF#1 nless noted otherwise in the framing plans Wall Schedule EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED NEW WALL SHEAR WALL NOTES - WALLS PX-X INDICATES SHEAR WALL. SEE LEGEND. SEE SHEAR WALL SCHEDULE FOR SHEAR WALL NOTES, ANCHOR BOLT PLACEMENT, PRESSURE TREATED SILL SIZES, AND INSTALLATION DETAILS. NOTIFY ENGINEER OF ANY REVISIONS TO SHEAR WALL OR FIELD MODIFICATIONS DUE TO UNFORESEEN CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION. DIAPHRAGM SHEATHING NAILS SHALL BE DRIVEN SO THAT THEIR HEAD OR CROWN IS FLUSH WITH THE SURFACE OF THE SHEATHING. THE FASTENERS USED IN THE SHEAR WALL DESIGN ARE 10d COMMONS OR 10d GALVANIZED BOX NAILS. ANY FASTENER SUBSTITUTION WILL HAVE TO BE REVIEWED BY ENGINEER PRIOR TO CONSTRUCTION. SOLID BLOCK BELOW SHEAR WALLS ABOVE. INDICATES SHEAR WALL TIE DOWN STRAP BETWEEN THE SHEAR WALL ABOVE AND THE FRAMING ABOVE OR THE WALLS BELOW. revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 O E o 00 • — A•+ o C/) a z wLU c� Q AMA M�e >� c O 0 rw RESUB Feb 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W � 1_L M 0 U M � w CU i U C) L M N This work was prepared by me or under my supervision. Sheet Contents: Scale: as noted 11 /9/22 Date: Job no.: T22J6 Drawn by: STT Sheet no.: S-3-0 \1 of 10 4" CONC SLAB #3 (::JIES @ 12" OC 444 BARS 1 1/2" 1 1/2" LONGITUDINAL TOP CLR - Z-611 CLR &BTM SCALE: 1 "=1'-0" HEATHING PER PLAN MIC CLIP AT EVERY EACH END OC SHEATHING ;,KING $ ROOF TRUSS 48" #4 X 12" 4" thick concrete slab w/ 6"x6" W2.9xW2.9 WWF (2)#4 BARS CONT on 6mil vapor barrier on 6" compacted fill FINISH GRADE 811 1'-0" (2)#4 BARS CONT DETAIL SCALE: 1 "=1'-0" 07 3/4" THICK BASE PLATE WITH 2-3/4" diameter X 15" LONG - EMBED INTO CONCRETE 12" 141 h�, r i LOLL- - ' I I I •.� � P � f d I 3)STEEL COLUMN BASE DETAIL -� NTS r'AACTr'1CZ r'NACT17 r'RACT1A r'C1F STRAPPING AT WALL SCALE: 1"=V-0" (W-14) 10 DECK FRAMING CROSS-SECTION 3/8" = 1'-0" rII IS JOOD I PLATE >T TOP r col. to base plate 3x nailer with 1 /2"d. threaded studs welded on @ 15" o.c. 2x nailer w1114" teks 12" o.c.(2 rows) (CJIP) BEAM TO COL. 3/1$" 14 hss ool_ I st 2-314-d. Base Plate 20 threaded rod l u , Section)01 HSS TUBE BEAM (SEE ELEVATION) 2 COLUMN TO BEAM CONNECTION nts MIN DBL STUDS SIDS %X3 SCREWS SEE HOLDOWN CALL -OUTS DN PLAN 'R TR BARRIER MAY BE REQUIRED EPDXY GROUT W/ SIMPSON SET-XP EPDXY (MIN EMBED = 10") DR TR 2X OR 3X SILL (SEE SHEAR WALL SCHEDULE ''/"0 (OR) %"0 ANCHOR 3OLT FOUNDATION TYPICAL HDU INSTALLATION AS A HOLDOWN (SHOWN "FLUSH", TOUCHING SILL PLATE) NOTE: SEE MANUFACTURER'S CATALOG FOR ADDITIONAL INFORMATION HOLDOWN INSTALLATION 6 SCALE: NTS HSS 6x5x1/2 steel tube ANGLE TO BEAM AND COLUMN :5x5/8 be ANGLE TO BEAM AND COLUMN ORigid Frame Elevation nts FLOOR SHEATHING NAILINGAT 61 N. NMIAAUM ON CENTER TO JOIST W TH HOLD-DOVM FLOOR JOIST HOLD -DC" OR SIMILAR 704SION DEVICE DECK JOIST 5 DECK TO FLOOR CONNECTION nts IN 9 BEAM TO POST CONNECTION DETAIL — nts R-10 RIGID a INSULATION 6 MIL VAPOR a BARRIER 2X STUDS 16" O.C. %" EXTERIOR PLYWOOD SHEAR WALL 4" CONC SLAB W/ 6"X6" W2.9XW2.9 WWF PR TR SILL PLATE W/ %" 0 AB PER SHEAR WALL SCHEDULE (2) #4 CONT TOP a #4 @ 10" OC (HORIZ) J — #4 E� 3" (VERT) @ 16" OC 4"0 PERF PVC IN 6" DRAIN ROCK ao J p 6" GRAVEL M A —III—II� II. 4" 8" 4" (2)#4 BTM LONGITUDINAL 1'-4" 2 TYPICAL FOUNDATION SCALE. 1 -1 -0 revisions 12/1 /22 12/8/22 1 /23/23 2/8/23 o _ � o 00 O •— r_ •— �_ ° N a w� Qz z UU >� L. O V m mil° W LL, f 0 LL M 13) � In o -� U co 6 2i w i� � U � c� L M N This work was prepared by me or under my supervision. Sheet Contents: Scale: as noted Date: 11 /9/22 Job no.: T22J6 Drawn by: STT Sheet no.: S-4.0 of i n