Loading...
Structural steel fabrication report 7-11-23DAILY FIELD REPORT 1' AAR TESTING AND INSPECTION, INC. 7126 180th Ave NE, Suite C101 Redmond, WA 98052 425-881-5812 Inspection Date 07/11/2023 Report Number BAV071123C CLIENT INFORMATION PROJECT INFORMATION Contact Johnny Project No. 23-359 Company Eurocraft Hardwood Floors LLC Project Name Morts Residence Address 8522 216th St SE Address 1034 B Avenue S City Woodinville City Edmonds Contractor Eurocraft Permit No. BLD2022-1670 INSPECTION TYPE(S) i STRUCTURE(S) / LOCATION(S) 0 Structural Steel Fabrication HSS components Weather Cloudy Temperature (OF) 63 Start Time 10:00 AM DRAWINGS / DOCUMENTS REFERENCED JAS Steel Fabricating drawing/E-1. AWS D1.1. End Time 10:50 AM INSPECTION OBSERVATION / REMARKS 1. I arrived at JAS Steel Fabricating to observe HSS components 6x5x1/2 (2), 8x4x.625, and 8x6x.625 are clean and beveled for welding in the field. 2. The HSS6x5x1/2 columns were welded all around to the 3/4"x5"x1'-2" base plates, with 3/16" fillet welds. 3. The welds are visually acceptable according to AWS D1.1 profiles. Items inspected are in conformance with approved plans, specifications, and jurisdictional requirements Inspectors Name Report Date Reviewers Signature Reviewed By Reviewed Date Inspectors Signature Brian Valukonis 07/11/2023 Teajalam (TJ) Gounden 07/15/2023 911-2/- Inspection Date 07/11/2023 Report Number BAV071123C ` DAILY FIELD REPORT AAR TESTING AND INSPECTION, INC. 7126 180th Ave NE, Suite C101 Redmond, WA 98052 425-881-5812 is Prepped areas are clean and beveled. HSS Columns at base plates 3/4"x5"x1-2". Inspectors Name Report Date Reviewers Signature Reviewed By Reviewed Date Inspectors signature Brian Valukonis 07/11/2023 Teajalam (TJ) Gounden 07/15/2023 e/ _