REV1 REVIEWED BLD2022-0865+Structural_Analysis_or_Calculations+4.10.2023_11.24.05_AM+3473191info@b2engineers.com
425-318-7047 (0)
425-318-0031 (C)
REVIEWED
BY
■
■
CITY OF EDMONDS
BUILDING DEPARTMENT
FULLER REMODEL EDMONDS
10631 229TH PL SW, EDMONDS, WA 98020
STRUCTURAL CALCULATIONS
PROJECT NO: 20202 DATE:03/29/23
PREPARED BY: BASR1 BASR1 PE, SE
Design Criteria
International Building Code (IBC) 2015
American Society of Civil Engineers (ASCE) 7-10
REVISION
Apr 10 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2022-0865
Page 1 of 6
VVA S y ,
43789
RA L
NIA 1
Project Description
REMOVAL OF EXISTING INTERIOR LOAD -BEARING WALLS. INSTALLATION OF NEW BEAMS, POSTS
AND FOOTINGS. PLEASE SEE ATTACHED CALCULATIONS.
Project: FULLER REMODEL EDMONDS
Location: RB-1
Roof Beam
Roof Beam [2021 International Building Code(2018 NDS)]
5.51Nx9.01Nx15.5FT
24F-V4 -Visually Graded Western Species -Dry Use
Section Adequate By: 20.5%
Controlling Factor: Moment
The Vitruvius Project, Inc. P`
StruCalc Version 11.1.2.0
CAUTIONS
The design dead load deflection exceeds the default maximum of 1/4" on spans (2).
DEFLECTIONS Center
Live Load 0.54 IN L/346
Dead Load 0.28 in
Total Load 0.82 IN L/227
Live Load Deflection Criteria: L/240
REACTIONS A B
Live Load 1208 lb 1208 lb
Dead Load 663 lb 663 lb
Total Load 1871 lb 1871 lb
Bearing Length 0.52 in 0.52 in
BEAM DATA
Span Length 15.5 ft
Unbraced Length -Top 0 ft
Unbraced Length -Bottom 0 ft
Roof Pitch 6 :12
Roof Duration Factor 1.15
Camber Adj. Factor 1.5
Camber Required 0.42
Notch Depth 0.00
Total Load Deflection Criteria: L/180
MATERIAL PROPERTIES
24F-V4 - Visually Graded Western Species
Base
Values
Adjusted
Bending Stress:
Fb
=
2400
psi
Controlled by:
Fb_cmpr
= 1850
psi
Fb'
= 2760
psi
Cd=1.15
Shear Stress:
Fv
=
265
psi
Fv'
= 305
psi
Cd=1.15
Modulus of Elasticity:
E =
1800
ksi
E' =
1800
ksi
Comp. �L to Grain:
Fc
- =
650
psi
Fc -
650
psi
Controlling Moment: 14175 ft-lb
7.75 ft from left support
Created by combining all dead and live loads.
Controlling Shear: -1871 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Read
Section Modulus: 61.63 in3
Area (Shear): 9.21 in2
Moment of Inertia (deflection): 265.13 in4
Moment: 14175 ft-lb
Shear: -1871 lb
Provided
74.25
in3
49.5
in2
334.13
in4
17078
ft-lb
10057
lb
LOADING D I AG RAM
ROOF LOADING
Side One:
Roof Live Load:
Roof Dead Load:
Tributary Width:
Side Two:
Roof Live Load:
Roof Dead Load:
Tributary Width:
Wall Load:
3/29/2023 12 : 54: 30 PM
1
15.5 ft
LL =
0
psf
D L =
0
psf
TW =
0
ft
LL =
0
psf
D L =
0
psf
TW =
0
ft
WALL = 0 plf
SLOPE/PITCH ADJUSTED LENGTHS AND LOADS
Adjusted Beam Length: Ladj = 15.5 ft
Beam Self Weight: BSW = 11 plf
Beam Uniform Live Load: wL = 0 plf
Beam Uniform Dead Load: wD_ad j = 11 plf
Total Uniform Load: wT = 11 plf
POINT LOADS - CENTER SPAN
Load Number One
Live Load 2415 lb
Dead Load 1160 lb
Location 7.75 ft
1
12zf 6
of
Project: FULLER REMODEL EDMONDS
Location: RB-2
Roof Beam
Roof Beam [2021 International Building Code(2018 NDS)]
5.51Nx9.01Nx15.5FT
24F-V4 -Visually Graded Western Species -Dry Use
Section Adequate By: 29.5%
Controlling Factor: Moment
The Vitruvius Project, Inc. P`
StruCalc Version 11.1.2.0
CAUTIONS
The design dead load deflection exceeds the default maximum of 1/4" on spans (2).
DEFLECTIONS Center
Live Load 0.50 IN L/371
Dead Load 0.26 in
Total Load 0.76 1 N L/244
Live Load Deflection Criteria: L/240
REACTIONS
A
B
Live Load
1125 lb
1125
lb
Dead Load
618 lb
618
lb
Total Load
1743 lb
1743
lb
Bearing Length
0.49 in
0.49
in
BEAM DATA
Span Length
15.5
ft
Unbraced Length
-Top
0
ft
Unbraced Length
-Bottom
0
ft
Roof Pitch
6 :12
Roof Duration Factor 1.15
Camber Adj. Factor 1.5
Camber Required 0.39
Notch Depth 0.00
Total Load Deflection Criteria: L/180
MATERIAL PROPERTIES
24F-V4 - Visually Graded Western Species
Base
Values
Adjusted
Bending Stress:
Fb
=
2400
psi
Controlled by:
Fb_cmpr
= 1850
psi
Fb'
= 2760
psi
Cd=1.15
Shear Stress:
Fv
=
265
psi
Fv'
= 305
psi
Cd=1.15
Modulus of Elasticity:
E =
1800
ksi
E' =
1800
ksi
Comp. �L to Grain:
Fc
- =
650
psi
Fc -
650
psi
Controlling Moment: 13187 ft-lb
7.75 ft from left support
Created by combining all dead and live loads.
Controlling Shear: -1743 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Read
Section Modulus: 57.34 in3
Area (Shear): 8.58 in2
Moment of Inertia (deflection): 246.76 in4
Moment: 13187 ft-lb
Shear: -1743 lb
Provided
74.25
in3
49.5
in2
334.13
in4
17078
ft-lb
10057
lb
LOADING D I AG RAM
ROOF LOADING
Side One:
Roof Live Load:
Roof Dead Load:
Tributary Width:
Side Two:
Roof Live Load:
Roof Dead Load:
Tributary Width:
Wall Load:
3/29/2023 12 : 54: 30 PM
1
15.5 ft
LL =
0
psf
D L =
0
psf
TW =
0
ft
LL =
0
psf
D L =
0
psf
TW =
0
ft
WALL = 0 plf
SLOPE/PITCH ADJUSTED LENGTHS AND LOADS
Adjusted Beam Length: Ladj = 15.5 ft
Beam Self Weight: BSW = 11 plf
Beam Uniform Live Load: wL = 0 plf
Beam Uniform Dead Load: wD_ad j = 11 plf
Total Uniform Load: wT = 11 plf
POINT LOADS - CENTER SPAN
Load Number One
Live Load 2250 lb
Dead Load 1070 lb
Location 7.75 ft
72r-F:' •1 •
of
Project: FULLER REMODEL EDMONDS
Location: RB-3
Multi -Loaded Multi -Span Beam
Multi -Loaded Multi -Span Beam [2021 International Building Code(2018 NDS)]
5.51Nx9.01Nx14.75FT
24F-V4 -Visually Graded Western Species -Dry Use
Section Adequate By: 11.7%
Controlling Factor: Deflection
The Vitruvius Project, Inc. P`
StruCalc Version 11.1.2.0
CAUTIONS
The design dead load deflection exceeds the default maximum of 1/4" on spans (2).
DEFLECTIONS Center
Live Load 0.57 IN L/310
Dead Load 0.31 in
Total Load 0.88 IN L/201
Live Load Deflection Criteria: L/240
REACTIONS A B
Live Load 2252 lb 2854 lb
Dead Load 1218 lb 1549 lb
Total Load 3470 lb 4403 lb
Bearing Length 0.97 in 1.23 in
BEAM DATA
Total Load Deflection Criteria: L/180
('.AntAr
Span Length 14.75 ft
Unbraced Length -Top 0 ft
Unbraced Length -Bottom 14.75 ft
Live Load Duration Factor 1.15
Camber Adj. Factor 1.5
Camber Required 0.46
Notch Depth 0.00
MATERIAL PROPERTIES
24F-V4 - Visually Graded Western Species
Base Values
Bending Stress:
Shear Stress:
Modulus of Elasticity:
Comp. -Lto Grain:
Fb =
F b_c m p r =
Cd=1.15
Fv =
Cd=1.15
E=
Fc-�=
2400 psi
1850 psi
Adjusted
Controlled by:
Fb' = 2760 psi
265
psi
Fv' =
305
psi
1800
ksi
E' =
1800
ksi
650
psi
Fc - -L' =
650
psi
Controlling Moment: 13441 ft-lb
6.05 Ft from left support of span 2 (Center Span)
Created by combining all dead loads and live loads on span(s) 2
Controlling Shear: -4403 lb
15.0 Ft from left support of span 2 (Center Span)
Created by combining all dead loads and live loads on span(s) 2
Comparisons with required sections:
Section Modulus:
Area (Shear):
Moment of Inertia (deflection):
Moment:
Shear:
Req'd
58.44
in3
21.67
in2
299.23
i n4
13441
ft-lb
-4403
lb
Provided
74.25
in3
49.5
in2
334.13
in4
17078
ft-lb
10057
lb
LOADING D I AG RAM
UNIFORM LOADS
Uniform Live Load
Uniform Dead Load
Beam Self Weight
Total Uniform Load
E
Center
188 plf
90 plf
11 plf
289 plf
3/29/2023 12 : 54: 31 PM
14.75 ft
POINT LOADS - CENTER SPAN
Load Number One * Two
Live Load 1125 lb 1208 lb
Dead Load 618 lb 663 lb
Location 4.75 ft 13.5 ft
* Load obtained from Load Tracker. See Summary Report for details.
/ of
2
Project: FULLER REMODEL EDMONDS
Location: P-1
Column
Column [2021 International Building Code(2018 NDS)]
3.51Nx5.51Nx9.0FT
Stud -Hem-Fir -Dry Use
Section Adequate By: 32.2%
VERTICAL REACTIONS
Live Load:
Dead Load:
Total Load:
Vert-LL-Rxn
=
2854
lb
Vert-DL-Rxn
=
1581
lb
Vert-TL-Rxn
=
4435
lb
COLUMN DATA
Total Column Length: 9 ft
Unbraced Length (X-Axis) Lx: 9 ft
Unbraced Length (Y-Axis) Ly: 9 ft
Column End Condition-K (e): 1
Axial Load Duration Factor 1.15
COLUMN PROPERTIES
Stud - Hem -Fir
Compressive Stress:
Bending Stress (X-X Axis):
Bending Stress (Y-Y Axis):
Modulus of Elasticity:
Base Values Adjusted
Fc = 800 psi Fc' = 340
Cd=1.15
Cp=0.37
Fbx
= 675
psi
Fbx' _
Cd =1.15
CF=1.00
Cf=1.18
Fby
= 675
psi
Fby' _
Cd =1.15
CF=1.00
Cf=1.18
psi
916 psi
916 psi
E = 1200 ksi E' = 1200 ksi
Column
Section (X-X Axis):
dx =
5.5
in
Column
Section (Y-Y Axis):
dy =
3.5
in
Area:
A =
19.25
in2
Section
Modulus (X-X Axis):
Sx =
17.65
in3
Section
Modulus (Y-Y Axis):
Sy =
11.23
in3
Slenderness Ratio:
Lex/dx =
19.64
Ley/dy =
30.86
Column Calculations (Controlling Case Only):
Controlling Load Case: Axial Total Load Only (L + D)
Actual Compressive Stress:
Fc =
230
psi
Allowable Compressive Stress:
Fc' =
340
psi
Eccentricity Moment (X-X Axis):
Mx -ex =
0
ft-Ib
Eccentricity Moment (Y-Y Axis):
My-ey =
0
ft-lb
Moment Due to Lateral Loads (X-X Axis):
Mx =
0
ft-lb
Moment Due to Lateral Loads (Y-Y Axis):
My =
0
ft-lb
Bending Stress Lateral Loads Only (X-X Axis):
Fbx =
0
psi
Allowable Bending Stress (X-X Axis):
Fbx' =
916
psi
Bending Stress Lateral Loads Only (Y-Y Axis):
Fby =
0
psi
Allowable Bending Stress (Y-Y Axis):
Fby' =
916
psi
Combined Stress Factor:
CSF =
0.68
The Vitruvius Project, Inc. P`
StruCalc Version 11.1.2.0
LOADING DIAGRAM
B
9ft
A
3/29/2023 12 : 54: 31 PM
1
AXIAL LOADING
Live Load:
PL =
2854
lb
Dead Load:
P D =
1549
lb
Column Self Weight:
CSW =
32
lb
Total Axial Load:
PT =
4435
lb
*
Load
obtained
from
Load
Tracker.
See Summary
Report
for details.
/ of
Project: FULLER REMODEL EDMONDS
Location: F-1
Footing
Footing [2021 International Building Code(2018 NDS)]
Footing Size: 2.0 FT x 2.0 FT x 10.00 IN
Reinforcement: #4 Bars @ 8.00 IN. O.C. E/W / (3) min.
Section Footing Design Adequate
FOOTING PROPERTIES
Allowable Soil Bearing Pressure:
Qs =
1500
psf
Concrete Compressive Strength:
F'c =
2500
psi
Reinforcing Steel Yield Strength:
Fy =
40000
psi
Concrete
Reinforcement
Cover:
c =
3
in
FOOTING SIZE
Width: W = 2 ft
Length: L = 2 ft
Depth: Depth = 10 in
Effective Depth to Top Layer of Steel: d = 6.25 in
COLUMN AND BASEPLATE SIZE
Column Type: Wood
Column Width: m = 4 in
Column Depth: n = 6 in
FOOTING CALCULATIONS
Bearing Calculations:
Ultimate Bearing Pressure:
Qu =
1109
Effective Allowable Soil Bearing Pressure:
Qe =
1375
Required Footing Area:
Areq =
3.23
Area Provided:
A =
4.00
Baseplate Bearing:
Bearing Required:
Bear =
6464
Allowable Bearing:
Bear -A =
66300
Beam Shear Calculations (One Way Shear):
Beam Shear:
Vu1 =
1549
Allowable Beam Shear:
Vc1 =
11250
Punching Shear Calculations (Two Way Shear):
Critical Perimeter:
Bo =
45
Punching Shear:
Vu2 =
5055
Allowable Punching Shear (ACI 11-35):
vc2-a =
49219
Allowable Punching Shear (ACI 11-36):
vc2-b =
79688
Allowable Punching Shear (ACI 11-37):
vc2-c =
42188
Controlling Allowable Punching Shear:
vc2 =
42188
Bending Calculations:
Factored Moment:
Mu =
19391
Nominal Moment Strength:
Mn =
127575
Reinforcement Calculations:
Concrete Compressive Block Depth:
a =
0.46
Steel Required Based on Moment:
As(1) =
0.09
Min. Code Req'd Reinf. Flex. Members (ACI-150.1):
As(2) =
0.48
Controlling Reinforcing Steel:
As-regd =
0.48
Selected Reinforcement: #4's @ 8.0
in. o.c. e/w
(3) Min.
Reinforcement Area Provided:
As =
0.59
Development Length Calculations:
Development Length Required:
Ld =
15
Development Length Supplied:
Ld-sup =
9
Note: Plain concrete adequate for bending,
therefore
adequate
development
length
not
required.
psf
psf
sf
sf
in
lb
lb
lb
lb
lb
in -lb
in -lb
in
in2
in2
in2
in2
in
in
The Vitruvius Project, Inc. P`
StruCalc Version 11.1.2.0
3/29/2023 12 : 54: 32 PM
72r- /`. fl •
/ of
LOADING DIAGRAM 6 in
10 in
3 in
2 ft
�4 in
10 in
n n
3 in
2 ft
FOOTING LOADING
Live Load:
P L =
2854
lb
Dead Load:
P D =
1581
lb
Total Load:
PT =
4435
lb
Ultimate Factored Load:
Pu =
6464
lb
Footing plus soil above footing
weight: Wt =
322
lb
* Load obtained from Load Tracker.
See Summary
Report for details.