Loading...
SEE REV1 REVIEWED BLD2022-0865+Structural_Analysis_or_Calculations+7.1.2022_11.28.30_AM+2966897BLD2022-0865 1 /8 info@b2engineers.com 425-318-7047 (0) 425-318-0031(C) REVIEWED BY CITY OF EDMONDS!: BUILDING DEPARTMENT FULLER REMODEL EDMONDS 10631 229TH PL SW, EDMONDS, WA 98020 STRUCTURAL CALCULATIONS PROJECT NO: 20202 DATE:06-01-21 PREPARED BY: BASRI BASRI PE, SE )esign Criteria International Building Code (IBC) 2015 American Society of Civil Engineers (ASCE) 7-10 RECEIVED Jul 05 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 3roject Description REMOVAL OF EXISTING INTERIOR LOAD -BEARING WALLS. INSTALLATION OF NEW BEAMS, POSTS AND FOOTINGS. PLEASE SEE ATTACHED CALCULATIONS. �'P Bq P OF WAS,,,S'A • Z A.'PL 43788 p o� crURAL ENONG\ SS/ONAL Q- E 2 /8 RECEIVED nrl Onoo 10 3 /8 FULLER REMODEL CALCULRECEWED Jul 05 2022 CITY OF EDMONDS DEVELOPMENT S RVICES DEPARTME, O IMPORTANT NOTE: �- Z. CONTRACTOR SHALL PROVIDE w TEMPORARY SHORING AS p REQUIRED PRIOR ANY WORK O z /0 X W Z 0 II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II I_ B1 NEW 3.5X9.25 II II �P II II II II II II II II II I�� II II II II II II PSL BEAM SB1-1)II II II EXST. II II II II II II II II II II II II II II II II II � II II II II II II II 1 II II I II II II II II II II II II I II II II II II � I II II II II II — I�I II II II II II II II II I II II PORTION OF EXISTING WALL TO BE REMOVED - P II— —_u— II II II II II II II II II II � II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II 1 (2>2xa EXST II II II II II � II II II II II II II� II II II II II I II II II II II II II �, II II II I II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II � II II II II II II II h II II II II II II II II II II II I II II II II II II II II II II II II II II II II II II II II II II II II II II II EXISTING FLOORI II FRAMING TO REMAIN II II II II II II II II II II II II II II II II II II II- II I II II II II II II II II II II II II II II I II �.II II �I II 11 II IP, II FIRST FLOOR B1-1 AND B1-2 ARE DENOTES BEAMS �I Lp EXST EXISTING FLOOR BEAMS TO REMAIN NEW 4X8 BEAM (61-2) II B�1-2 II p P p g-2 EXST �I oll II I II II II II W 0 WI a II II B1-2 a0 w SH2 ANEW 4X8 co zz ABEAM (31-2) 0 II II II ILI 3I ,4, II II P lJ II 1 1111 z 10 w EXST N OOII II II II I, W III II II II z Uj mll II II II O °II II II II I _OqI Il Il ,II II II II II II II II II II FLOOR EXISTING BEAMS TO REMAIN P EXST FULLER REMODEL CALCULATIONS 4 /8 REC ______ — Juio CITY OF EDMON DS - _ _ _ _ - - - - - _ _ = DEVELOPMENT SE ICES DEP THEN PROVIDE 4X8 HEADER _ (BELOW) (RB-1) RB-1 I II II I I I II II I I II I II II II I I II II I I I II II I I II II II I I II II II I II II II I I II II I I I II II I I II II II I II II I I II II I I I II II I I II II I II II II I I II II I I I II II I I II II Q g II II II I II II I I I II II I I II II II II II I II II I I I II II H 1I-1 I II II II I I II II II I I II II I I I II 11 NEW 4x81 II II II I I II II II I I II II I I I II BEAM (H1 -1) I II II 2 = = S2 -EXISTING ROOF - II II II II II II II II II II II FRAMING TO REMAIN II II II II I II II I I I II II II CONTRACTOR TO FIELD p p II II II II I II II I I I II VERIFY EXISTING I II _ _ _ _ _ _ II II II II II II II HEADERS; 4X8 (MIN)(RB-1) II II II II II II I II II I I I II II I RIYR-1 II II II I I II II II I I II II I I I II II I I II II EXISTING ROOF II II II II II II II 11 II II II II FRAMING TO REMAIN II II I I II II II I I II II II I I II II I I I II II I I II II = _ - _ _ _ _ _ _ - _ _ _ III I II II III I II III I I II III I II II II II II II II II II II II II = _ _ _ _ _ _ _ _ _ _ _ II II II III II III I I II III I II II II II II II II II II II II II - - - - - - - - - - - - - - - ROOF PLAN RB-1 AND H1-1 ARE DENOTES ROOF BEAMS 5 /8 BeamChek v2020 licensed to: B2 Engineers Reg # 5508-68754 FULLER REMODEL EDMONDS B1-1 Date: 12/08/20 Selection 3-1/2x 9-1/4 2.0E TJ Parallam W.S. PSL Lu = 0.0 Ft Conditions NDS 2015 Data Attributes Actual Critical Status Ratio Values Adiustments Min Bearing Area R1= 2.6 inz R2= 2.1 in (1.5) DL Defl= 0.22 in ]ECEIVED Elul 05 2022 (CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Beam Span 14.6 ft Reaction 1 LL 1040 # Reaction 2 LL 782 # Beam Wt per ft 10.12 # Reaction 1 TL 1633 # Reaction 2 TL 1342 # Bm Wt Included 148 # Maximum V 1633 # Max Moment 4219 '# Max V (Reduced) 1625 # TL Max DefI L / 240 TL Actual Defl L / 390 LL Max Defl L / 360 LL Actual Defl L / 767 Section (in3) Shear (in 2) TL Defl (in) LL Defl 49.91 32.38 0.45 0.23 14.75 7.31 0.73 0.49 OK OK OK OK 30% 23% 62% 47% Fb (psi) Fv (psi) E (psi x mil) Fc! (psi) Reference Values 2900 290 2.0 625 Adjusted Values 3433 334 2.0 625 CIF Size Factor 1.029 Cd Duration 1.15 1.15 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Loads Point LL Point TL Distance Par Unif LL Par Unif TL Start End 437 B = 639 10.0 100 H = 178 10.0 14.6 925 C = 1369 1.5 H Pt loads: 0 0 R1 = 1633 R2 = 1342 SPAN = 14.6 FT Uniform and partial uniform loads are Ibs per lineal ft. FOOTING CALCULATIONS: TOTAL LOAD (TL) = 1,633 LBS SOIL BEARING CAPACITY (SBC) = 1,500 PSF TL/SBC = 1.088 SF (REQUIRED) 1.5'X1.5' = 2.25 SF (PROVIDED) /OK 6 /8 BeamChek v2020 licensed to: B2 Engineers Reg # 5508-68754 FULLER REMODEL EDMONDS B1-2 Date: 12/08/20 Selection 4x 8 DF-L #2 Lu = 0.0 Ft Conditions NDS 2015 Min Bearing Area R1= 5.2 in R2= 0.8 in (1.5) DL Defl= 0.01 in Data Attributes Actual Critical Status Ratio Values Adiustments Beam Span 4.0 ft Reaction 1 LL 2188 # Reaction 2 LL Beam Wt per ft 6.17 # Reaction 1 TL 3250 # Reaction 2 TL Bm Wt Included 25 # Maximum V 3250 # Max Moment 1631 '# Max V (Reduced) 2608 # TL Max Defl L / 240 TL Actual Defl L / >1000 LL Max Defl L / 360 LL Actual Defl L / >1000 ]ECEIVED Elul 05 2022 (CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 313 # 475 # Section (W) Shear (in 2) TL Defl (in) LL Defl 30.66 25.38 0.02 0.01 14.55 18.90 0.20 0.13 OK OK OK OK 47% 74% 12% 11% Fb (psi) Fv (psi) E (psi x mil) Fc! (psi) Reference Values 900 180 1.6 625 Adjusted Values 1346 207 1.6 625 CIF Size Factor 1.300 Cd Duration 1.15 1.15 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Loads Point LL Point TL Distance 2500 B = 3700 0.5 Pt loads: 0 0 R1 = 3250 R2 = 475 SPAN = 4 FT Uniform and partial uniform loads are Ibs per lineal ft. 7 /8 BeamChek v2020 licensed to: B2 Engineers Reg # 5508-68754 FULLER REMODEL EDMONDS 1-11-1 Date: 6/01 /21 Selection 4x 8 HF #2 Lu = 0.0 Ft Conditions NDS 2015 Min Bearing Area R1= 1.9 in R2= 1.9 in (1.5) DL Defl= 0.05 in Data Attributes Actual Critical Status Ratio Values Adiustments Loads Beam S an 6 5 ft Reaction 1 LL 382 # Reac p Beam Wt per ft 6.17 # Reaction 1 TL Bm Wt Included 40 # Maximum V Max Moment 1274'# Max V (Reduced) TL Max Defl L / 240 TL Actual Defl LL Max Defl L / 360 LL Actual Defl 784 # Reaction 2 TL 784 # 638 # L/928 L / >1000 ]ECEIVED Elul 05 2022 (CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 382 # 784 # Section (W) Shear (inz) TL Defl (in) LL Defl 30.66 25.38 0.08 0.03 13.83 6.38 0.33 0.22 OK OK OK OK 45% 25% 26% 15% ro (psi) ry (psi) t (psi x mn) rc! Reference Values 850 150 1.3 405 Adjusted Values 1105 150 1.3 405 CIF Size Factor 1.300 Cd Duration 1.00 1.00 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Uniform LL: 118 Uniform TL: 235 = A Uniform Load A 0 R1 = 784 R2 = 784 SPAN =6.5FT Uniform and partial uniform loads are Ibs per lineal ft. 8 /8 BeamChek v2020 licensed to: B2 Engineers Reg # 5508-68754 FULLER REMODEL EDMONDS RB-1 Date: 12/08/20 Selection 4x 8 HF #2 Lu = 0.0 Ft Conditions NDS 2015 Min Bearing Area R1= 2.3 in R2= 2.3 in (1.5) DL Defl= 0.19 in Data Attributes Actual Critical Status Ratio Values Adiustments Beam Span 9.9 ft Reaction 1 LL 495 # Reaction 2 LL Beam Wt per ft 6.17 # Reaction 1 TL 912 # Reaction 2 TL Bm Wt Included 61 # Maximum V 912 # Max Moment 2256'# Max V (Reduced) 800 # TL Max Defl L / 240 TL Actual Defl L / 348 LL Max Defl L / 360 LL Actual Defl L / 795 ]ECEIVED Elul 05 2022 (CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 495 # 912 # Section (W) Shear (in 2) TL Defl (in) LL Defl 30.66 25.38 0.34 0.15 21.31 6.96 0.50 0.33 OK OK OK OK 69% 27% 69% 45% Fb (psi) Fv (psi) E (psi x mil) Fc! (psi) Reference Values 850 150 1.3 405 Adjusted Values 1271 173 1.3 405 CIF Size Factor 1.300 Cd Duration 1.15 1.15 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 Cl Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Loads Uniform LL: 100 Uniform TL: 148 = A Par Unif TL Start End H = 30 0 9.9 H Uniform Load A 0 R1 =912 R2=912 SPAN =9.9FT Uniform and partial uniform loads are Ibs per lineal ft.