APPROVED BLD RESUB1 BLD2022-1385+Architectural_Plan+10.27.2022_10.28.58_AM+3188631GENERAL NOTES BUILDING CODE INFORMATION 1. THE FOLLOWING NOTES REFER TO NEW CONSTRUCTION WORK TO BE PROJECT DESCRIPTION PERFORMED UNDER PERMIT FROM THE LOCAL JURISDICTION AS DESCRIBED DEMO EXISTING DECK AND BUILD NEW ON THE ATTACHED "CONSTRUCTION SET" DRAWINGS AND SPECIFICATIONS. PARCEL NO. 00724700000100 2. CONTRACTOR SHALL FIELD VERIFY ALL CRITICAL DIMENSIONS AND SITE CONDITIONS INCLUDING LOCATION AND DISPOSITION OF EXISTING UTILITIES JURISDICTION CITY OF EDMONDS BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR SAME. NOTIFY DESIGNER OF ANY DISCREPANCIES AND DO NOT PROCEED WITH ANY APPLICABLE CODES RELATED WORK UNTIL DISCREPANCY HAS BEEN REMOVED. 2018 INTERNATIONAL RESIDENTIAL CODE W/ STATEWIDE AMENDMENTS 3. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE CODES. CITY OF EDMONDS MUNICIPAL CODE WHERE CONFLICTS OCCUR BETWEEN METHODS OR STANDARDS OF INSTALLATION AND CODES, OR IF MATERIALS DO NOT EQUAL OR EXCEED THE CONSTRUCTION TYPE V-B REQUIREMENTS OF LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY DESIGNER OF ANY CONFLICTS. OCCUPANCY R-3 4. DO NOT SCALE THE DRAWINGS. THE CONTRACTOR(S) SHALL USE ACTUAL FIELD DIMENSIONS OR DIMENSIONS SHOWN ON THE DRAWINGS. NOTIFY THE FLOOR AREA DESIGNER OF ANY DISCREPANCIES AND DO NOT PROCEED WITH ANY RELATED WORK UNTIL DISCREPANCY HAS BEEN RESOLVED. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS AND SEQUENCE OF CONSTRUCTION REQUIRED TO PERFORM THE WORK. 6. SUB -CONTRACTORS SHALL VERIFY ROUGH -IN DIMENSIONS, REQUIREMENTS FOR BACKING AND LOCATIONS OF ITEMS IN PARTITIONS AS REQUIRED FOR INSTALLATION OF THEIR WORK. EACH INSTALLER SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION WITH OTHER INSTALLERS TO SECURE COMPLIANCE WITH THE CONTRACT DRAWINGS AND RELATED SPECIFICATIONS. GENERAL CONTRACTOR SHALL COORDINATE INSTALLATION OF EQUIPMENT, PLUMBING FIXTURES AND APPLIANCES INCLUDED IN THIS CONTRACT OR FURNISHED BY OTHERS FOR INSTALLATION BY CONTRACTOR. 7. PRIOR TO SHOP FABRICATION OF MATERIALS OR EQUIPMENT OR ORDERING OF MANUFACTURED ITEMS, RESPECTIVE SUB -CONTRACTOR OR SUPPLIER SHALL PROVIDE SHOP DRAWINGS OR MANUFACTURER'S DATA FOR REVIEW BY OWNER AND DESIGNER. 8. ANY ALTERATIONS TO STRUCTURAL ELEMENTS OR BUILDING SHELL DESIGN SHALL NOT BE DONE WITHOUT PRIOR AUTHORIZATION FROM DESIGNER. ALL CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED TO DESIGNER IN NAME EXISTING DEMO NEW TOTAL BASEMENT 2324 S.F. 2324 S.F. FIRST FLOOR 2324 S.F. 2324 S.F. TOTAL CONDITIONED 4648 S.F. 4648 S.F. GARAGE 256 S.F. 256 S.F. DECK 448 S.F. 560 S.F. 560 S.F. WRITING FOR APPROVAL. City Of Edmonds 9. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR LICENSED TESTING AND, Building Department IF REQUIRED, ABATEMENT OF ANY HAZARDOUS MATERIALS DISTURBED DURING SITE CLEARING AND PREPARATION. Work DECK ----------------------- -------------- ------------- --------- 10. SOIL CONDITIONS DISCOVERED DURING EXCAVATION WHICH APPEAR Address 1125 OLYMPIC AVE INCONSISTENT WITH THE ALLOWABLE SOIL BEARING PRESSURE ASSUMED=============================================================== SHALL BE REPORTED TO THE DESIGNER. THE ACTUAL ELEVATIONS OF THE Owner COOPER FOOTINGS WILL BE ESTABLISHED BY THE CONTRACTOR AND MUST BEAR ON --------- ---------------- SOLID UNDISTURBED EARTH OR CONTROLLED AND COMPACTED STRUCTURAL Approved Date 11/03/2022 FILL. SEE STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. Building Official w. 1i o1L ------------- 11. CONTRACTOR SHALL PROVIDE ALL TEMPORARY SUPPORTS AND BRACING Permit Number BLD2022-1385 AS REQUIRED. INSTALL TEMPORARY BARRIERS AS NECESSARY TO PROTECT ADJACENT STREET RIGHT-OF-WAY AND NEIGHBORING PROPERTIES. CONTRACTOR SHALL BE RESPONSIBLE FOR STRENGTH AND SUITABILITY OF APPROVED TEMPORARY BARRIERS AND SUPPORTS PER CITY AND COUNTY STANDARDS. PLANS MUST BE ALL TEMPORARY WORK SHALL BE REMOVED AT THE END OF EACH SEQUENCE ON JOB SITE OR AT COMPLETION OF THE CONTRACT WORK. 12. MECHANICAL AND ELECTRICAL TO BE BIDDER -DESIGN UNDER SEPARATE PERMIT. CONTRACTOR SHALL SUBMIT PLANS TO DESIGNER FOR REVIEW PRIOR TO CONSTRUCTION. CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL WORK AND OBTAIN SHOP DRAWINGS FOR REVIEW BY DESIGNER BEFORE PROCEEDING WITH THE WORK. 14. REPETITIOUS DETAILS MAY BE CALLED OUT RARELY ON THE DRAWINGS BUT SHALL BE PROVIDED AT ALL LOCATIONS WHERE THEY OCCUR. 15. ALL WORKMANSHIP SHALL BE OF THE HIGHEST QUALITY AND IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS FOR USE. WORKMANSHIP QUALITY SHALL BE JUDGED ACCORDING TO THE BEST ACCEPTED STANDARDS OF THE BUILDING INDUSTRY. CONTRACTOR SHALL CORRECT ALL DEFECTIVE WORK TO SATISFACTION OF OWNER AT CONTRACTOR'S EXPENSE AND IN A TIMELY MANNER. A PUNCH LIST WILL BE ISSUED AT COMPLETION OF PROJECT. NOTIFY DESIGNER AT SUBSTANTIAL COMPLETION. 16. ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE OF COMPLETED PROJECT BY OWNER. ROOFING, WATERPROOFING, FLASHINGS AND ALL OTHER WORK WHICH IS A COMPONENT PART OF THE ROOFING IS TO BE WEATHERTIGHT UNDER ORDINARY WEAR AND USAGE FOR A PERIOD OF TWO YEARS FROM DATE OF ACCEPTANCE, TO BE SUPPLEMENTED BY THE TERMS AND CONDITIONS OF EXTENDED MANUFACTURER'S WARRANTIES. AT TIME OF ACCEPTANCE OF COMPLETED PROJECT, CONTRACTOR SHALL FURNISH OWNER WITH ALL NECESSARY MANUALS OF OPERATION AND MAINTENANCE, WARRANTIES AND GUARANTEES FOR ALL EQUIPMENT INCLUDED IN THIS CONTRACT. 17. ANY METAL IN CONTACT WITH TREATED WOOD MUST BE VERIFIED FOR THAT USE OR ISOLATED FROM DIRECT CONTACT. DEMO EXT'G. DECK COMPLETE PROVIDE SILT FENCE AROUND PROJECT AREA DURING CONSTRUCTION FOR EROSION CONTROL 144 EXT'G. SIDE SEWARD ZONING INFORMATION ZONING LEGAL DESCRIPTION RS-12 EDMONDS VIEW ESTATES BILK 000 LOT 1 0.18 ACRES (APPROX. 7840 S.F.) 25 FT FRONT 25 FT SIDE 10 FT LOT COVERAGE ALLOWED LOT COVERAGE GROSS LOT AREA (.30 ACRES EXT'G. HOUSE & GARAGE NEW DECK EXT'G. SHED TOTAL LOT COVERAGE % OF LOT COVERAGE 146 148 35 % DRAWING INDEX A1.1 PROJECT INFORMATION / SITE PLAN A2.1 NEW DECK FOUNDATION / UPPER DECK PLAN / ELEVATIONS S1.0 GENERAL STRUCTURAL NOTES S2.0 FOUNDATION PLAN S2.1 DECK FRAMING PLAN S3.0 STRUCTURAL DETAILS CONTACT INFORMATION OWNER / PROPERTY ADDRESS KAREN & NICHOLAS COOPER 1125 OLYMPIC AVE EDMONDS, WA 98020 EMAIL: KACCOOP@COMCAST. NET 13068 SF DESIGNER AARON DUPONT 28809 40TH AVE S 2580 SF AUBURN, WA 98001 560 SF 206-348-4483 EMAIL: AKD.ARCHDESIGN@GMAIL.COM 72 SF 3212 SF 3212 / 13068 = 24.6 % ■r.... . & I . .... 125.00 0 5 10 20 iews. STRUCTURAL ENGINEER HARRIOTT VALENTINE ENGINEERS INC 1932 FIRST AVE, STE 720 SEATTLE, WA 98101 154 206-413-6671 EMAIL: TFISHER@HARRIOTTVA ENTINE.COM 25.0 FRONT W a U_ IL 5 J O Residential Designer 206.348.4483 akd.archdesign@gmail.com COOPER RESIDENCE NEW DECK 1 125 OLYMPIC AVE EDMONDS, WA 98020 Revision 1 REVISION 10/26/2022 RESUB Oct 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT INFORMATION / SITE PLAN ❑ Preliminary Design ❑ Progress Set ❑ Pricing Set ■ Permit Set ❑ Construction Set Date: 9/26/2022 Design: AD Scale: AS NOTED Sheet No. Al 1 ■ NEW UPPER FLOOR DECK PLAN )TES =DGER FLASHING & COUNTER FLASHING TO BE GAUGE CORROSION -RESISTANT METAL & SHALL BE _ED IN COMPLIANCE W/ IRC R703.8. OD BEARING ON UNPROTECTED CONCRETE OR RY, EXPOSED TO WEATHER, OR WITHIN 6" OF !D GRADE SHALL BE PRESSURE TREATED. RAIL SHALL BE IN ACCORDANCE WITH IRC R312.1; E 36" HIGH MIN. GUARDRAIL WITH INTERMEDIATE J/ 3 7/8" MAX SPACING. GEND DEMOLITION EXISTING CONSTRUCTION ELEVATION NOTES 1. THESE NOTES APPLY TO ALL EXTERIOR ELEVATIONS. 2. DECK LEDGER FLASHING AND COUNTER FLASHING TO BE MIN. 26 GAUGE CORROSION -RESISTANT METAL, AND SHALL BE INSTALLED IN COMPLIANCE WITH IRC R703.8. 3. GUARDRAIL SHALL BE IN ACCORDANCE WITH IRC R312.1; PROVIDE 36" HIGH MIN. GUARDRAIL WITH INTERMEDIATE RAILS W/ 3 7/8" MAX SPACING. GUARDRAIL PER NOTE 0 i0 TOP OF DECK 2x12 FASCIA BEAM PER STRL. N P.T. 4x4 KNEE BRACE PER STRL. 6' POST PER STRL. FINISH GRADE I I I I I I I I I I L___J L___J L___J L___J L___J WEST ELEVATION 1/4" = 1'-01, M N ci 0 LINE OF DECK ABOVE DEMO EXT'G. DECK POSTS (TYP. OF 5) EXT'G. GRAVEL N AREA NEW POST PER STRL. (TYP. OF 6) I M NO M NO cM N NEW BEAM PERK STRL. NEW FTG. PER STRL. (TYP. OF 6) FASCIA MC GUARDRAI PER NOTE 0 c� TOP OF DE 2x12 FASCI BEAM PER STRL. N U_ POST PER a, j STRL. FINISH GRA NEW DECK FOUNDATION PLAN SOUTH ELEVATION 1/4" = V-0" Residential Designer 206.348.4483 akd.archdesign@gmail.com COOPER RESIDENCE NEW DECK 1 125 OLYMPIC AVE EDMONDS, WA 98020 Revision 1 REVISION 10/26/2022 RESUB Oct 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT NEW DECK FOUNDATION / UPPER DECK PLAN / ELEVATIONS ❑ Preliminary Design ❑ Progress Set ❑ Pricing Set ■ Permit Set ❑ Construction Set Date: 9/26/2022 Design: AD Scale: AS NOTED Sheet No. A201 �M HVE GENERAL STRUCTURAL NOTES (THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS) 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS & THE INTERNATIONAL BUILDING CODE (2018 EDITION). 2. DESIGN LOADING CRITERIA: FLOOR LIVE LOAD (RESIDENTIAL DECK) . . . . . . . . . . . . . . . 60 PSF EARTHQUAKE: LAT. / LONG. . . . . . . . . . 47.819 /-122.362 SEISMIC IMPORTANCE FACTOR (Ie) . . . . . . . . . . . . . . . . . . . 1.0 SEISMIC USE GROUP. . . . I MAPPED SPECTRAL RESPONSE (Ss/Si). . . . . . . . . . . . . . 1.29g/O.46g SPECTRAL RESPONSE COEF. (SDS/SD1) . . . . . . . . . . . . . 0.869/0.46g SEISMIC FORCE RESISTING SYSTEM: . . . . . . . . . . PLYWOOD SHEAR WALLS DESIGN BASE SHEAR . . . . . . . . . . . . . . . . . . . . . . . . 4.95k SEISMIC RESPONSE COEFICIENT (Cs) . . . . . . . . . . . . . . . . . 0.574 SEISMIC DESIGN CATEGORY . . . . . . . . . . . . . . . . . . . . . . . . D RESPONSE MODIFICATION FACTOR (R) . . . . . . . . 1.5 ANALYSIS PROCEDURE . . . . . . . . . . . . . . .EQUIVALENT LATERAL FORCE REFERENCE: USGS NATIONAL SEISMIC HAZARD MAPPING PROJECT, 2008 DATA 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CON- DITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CON- STRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST VERIFIED. CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL ADJACENT UNDERGROUND UTILITIES PRIOR TO COMMENCING EXCAVATION. THE CONTRACTOR SHALL BRING ALL CONFLICTS AND DISCREPANICES TO THE ATTENTION OF THE ARCHITECT AND STRUCTURAL ENGINEER. 5. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. EXISTING REINFORCING SHALL BE RETAINED UNDAMAGED WHERE NOTED ON THE PLANS. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. ALL NEW OPENINGS THROUGH EXISTING CONCRETE OR MASONRY WALLS, SLABS AND BEAMS SHALL BE ACCOMPLISHED BY SAW CUTTING WHEREVER POSSIBLE. 6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CON- TRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CON - CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 8. SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OF THESE ITEMS. A. STRUCTURAL STEEL GEOTECHNICAL 9. FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED GRADE. UNLESS NOTED OTHERWISE, FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. ALLOWABLE SOIL PRESSURE . . . . . . . . . . 2,000 PSF LATERAL EARTH PRESSURE . . . . . . . . . . . 35 PCF CONCRETE 10. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORD- ANCE WITH ACI 301. CONCRETE SHALL ATTAIN A 28 DAY STRENGTH OF F'C = 2,500 PSI AND MIX SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC YARD AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. THE MINIMUM AMOUNTS OF CEMENT AND MAXIMUM AMOUNTS OF WATER MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE STRUCTURAL ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CON- CRETE. THE CONCRETE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER AND ADMIXTURES AS WELL AS THE WATER CE- MENT RATIO, SLUMP, CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH ACI 301. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF RECORD INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS GENERALLY WITH CONTRACT DOCUMENTS. CONTRACTOR OR SUPPLIER MAINTAINS FULL RESPONSIBILITY FOR SPECIFIED PERFORMANCE. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR ENTRAINED WITH AN AIR ENTRAINING AGENT CONFORMING TO ASTM C260, C494, AND C618. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WITH TABLE 19.3.2.1 OF THE ACI 318. 11. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, FY = 60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185. ALL REBAR SHALL BE 90% MINIMUM RECYCLED CONTENT. SUBMIT MANUFACURERS CERTIFICATE OF RECYCLED CONTENT TO ARCHITECT AND STRUCTURAL ENGINEER. 12. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORD- ANCE WITH ACI 318. LAP ALL CONTINUOUS REINFORCEMENT 40 BAR DIAMETERS OR 2' 0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTER- SECTIONS. LAP CORNER BARS 40 BAR DIAMETERS OR 2' 0" MINIMUM. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. 13. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: A. FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE . . .3" B. ALL OTHER SURFACES . . . . . . . . . . . . . . . . 1 1/2" ANCHORAGE 14. TITEN HD ANCHORS SPECIFIED ON THE DRAWINGS SHALL CONSIST OF "TITEN HD" HEAVY DUTY SCREW ANCHORS AS MANUFACTURED BY THE SIMPSON COMPANY AND INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 2713. STEEL 15. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL BE BASED ON THE LATEST EDITIONS OF THE AISC SPECIFICATIONS AND CODES: A. SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (RISC 360) B. CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES (RISC 303) C. SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. BOLTS IN SHEAR OR BEARING TYPE CONNECTIONS NEED ONLY BE TIGHTENED TO THE SNUG TIGHT CONDITION PER SECTION 8(C). 16. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING MINIMUM STANDARDS. PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36, FY = 36 KSI. WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, FY = 50 KSI. STEEL PIPE SHALL CONFORM TO ASTM A53, TYPE E OR S, GRADE B, FY = 35 KSI. SQUARE OR RECTANGULAR STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B, FY = 46 KSI. ANCHOR BOLTS AND CONNECTION BOLTS SHALL CONFORM TO ASTM A307. THREADED ROD AND STUDS SHALL CONFORM TO ASTM A36. WOOD 17. FRAMING LUMBER SHALL BE KILN DRIED OR MC-15, AND GRADED AND MARKED IN CON- FORMANCE WITH WCLIB STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17, LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (2X MEMBERS) (3X & 4X MEMBERS) STRUCTURAL LIGHT FRAMING ( I NCL. 3X AND 0 POSTS) HEM -FIR NO. 2 MINIMUM BASE VALUE, FB = 850 PSI DOUGLAS FIR NO. 1 MINIMUM BASE VALUE, FB = 1000 PSI DOUGLAS FIR NO. 2 MINIMUM BASE VALUE, FB = 900 PSI BEAMS AND STRINGERS: DOUGLAS FIR NO. 1 (INCL. 6X AND LARGER) MINIMUM BASE VALUE, FB = 1350 PSI POSTS AND TIMBERS: DOUGLAS FIR NO. 1 (6X6 AND LARGER) MINIMUM BASE VALUE, FC = 1000 PSI STUDS, PLATES & MISC. FRAMING: DOUGLAS FIR OR HEM -FIR STANDARD GRADE 2X6 STUDS AND PLATES: HEM -FIR NO.3/ STUD GRADE 2X AND 3X T & G DECKING HEM -FIR COMMERICAL DEX, MINIMUM BASE VALUE, FB = 1350 PSI 18. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH APA STANDARDS. ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND SPAN RATING MAY BE USED IN LIEU OF PLYWOOD. A. ROOF SHEATHING SHALL BE 1/2" (NOM.) WITH SPAN RATING 24/0. B. FLOOR SHEATHING SHALL BE 3/4" (NOM.) WITH SPAN RATING 40/20. C. WALL SHEATHING SHALL BE 1/2" (NOM.) WITH SPAN RATING 24/0. REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING. ALL SHEATHING SHALL BE FSC CERTIFIED AND SHALL BEAR THE FSC STAMP. 19. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE - TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY. ALL WOOD EXPOSED TO WEATHER WITHOUT THE ADEQUATE PROTECTION OF A ROOF OR EAVE SHALL BE AN APPROVED WOOD OF NATURAL RESISTANCE TO DECAY OR PRESSURE TREATED. SUCH MEMBERS INCLUDE HORIZONTAL MEMBERS SUCH AS GIRDERS, JOISTS, AND DECKING; OR VERTICAL MEMBERS SUCH AS POSTS, POLES, AND COLUMNS. 20. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR MOST RECENT CATALOG. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. UN- LESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEA- SONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. HANGERS IN DIRECT CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE EITHER STAINLESS STEEL (SST300), POST HOT -DIPPED GALVANIZED(HDG) OR GALVANIZED WITH A MINI- MUM OF 1.850Z ZINC PER SQUARE INCH (ZMAX). UNLESS NOTED OTHERWISE, ALL LUMBER JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST HANGERS, AND ALL TJI JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "ITT" OR "IUT" SERIES JOIST HANGERS. 21. NAILS - NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER 6D 2" 0. 113" 8D 2-1/2" 0. 131" 10D 3" 0.148" 12D 3-1/4" 0.148" 16D 3-1/2" 0.162" IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW AND APPROVAL. NAILS SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. 22. STAPLES - THE FOLLOWING STAPLES MAY BE SUBSTITUTED FOR NAILING OF PLYWOOD (APA RATED SHEATHING): NAIL SIZE EQUIV. STAPLE MINIMUM LENGTH 6D 16 GA. 1-3/4" 8D 15 GA. 1-3/4" 10D 13 GA. 1-3/4" IF CONTRACTOR PROPOSES THE USE OF ALTERNATE STAPLES, THEY SHALL SUBMIT STAPLE SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW AND APPROVAL. STAPLES SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. 23. WOOD FRAMING NOTES THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN: A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.10.1 OF THE INTERNATIONAL BUILDING CODE. UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. B. WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2X4 STUDS @ 16" 0. C. AT INTERIOR WALLS AND 2X6 @ 16" 0. C. AT EXTERIOR WALLS. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS. TWO 2X8 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COL- UMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH TWO 16D NAILS, AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16D NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16D AT 12" O.C. AND LAP MINIMUM 4'-0'$ AT JOINTS AND PROVIDE SIX 16D NAILS AT 4" O.C. EACH SIDE OF JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16D NAILS AT 12" O.C. STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS (WITH 7" MINIMUM EMBEDMENT)@ 4' 0" O.C. UNLESS INDICATED OTHERWISE. INDIVI- DUAL MEMBERS OF BUILT UP POSTS SHALL BE NAILED TO EACH OTHER WITH 16D @ 12" O.C. STAGGERED. REFER TO THE PLANS AND SHEAR WALL SCHEDULE FOR REQUIRED SHEATHING AND NAILING. WHEN NOT OTHERWISE NOTED, PROVIDE GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO ALL STUDS, TOP AND BOTTOM PLATES AND BLOCKING WITH NAILS AT 7" O.C. USE 5D COOLER NAILS FOR 1/2" GWB AND 6D COOLER NAILS FOR 5/8" GWB. WHEN NOT OTHERWISE NOTED, PROVIDE 1/2" (NOM.) APA RATED SHEATHING (SPAN RATING 24/0) ON EXTERIOR SURFACES NAILED AT ALL PANEL EDGES (BLOCK UNSUPPORTED EDGES), TOP AND BOTTOM PLATES WITH 8D @ 6" O.C. AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH 8D @ 12" O.C. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS. C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS AROUND ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE SOLID BLOCKING AT ALL BEARING POINTS. TOENAIL JOISTS TO SUPPORTS WITH TWO 16D NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH METAL JOIST HANGERS IN ACCORDANCE WITH TIMBER CONNECTOR NOTE. NAIL ALL MULTI JOIST BEAMS TO- GETHER WITH 16D @ 12" O.C. STAGGERED. UNLESS OTHERWISE NOTED ON THE PLANS, ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS AND NAILED WITH 8D NAILS @ 6" O.C. TO FRAMED PANEL EDGES AND OVER STUD WALLS AS SHOWN ON PLANS AND @ 12" O.C. TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED TONGUE AND GROOVE JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF ALL ROOF AND FLOOR SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH 16D @ 12" O.C. UNLESS OTHERWISE NOTED. AT BLOCKED FLOOR AND ROOF DIAPHRAGMS PROVIDE FLAT 2X BLOCKING AT ALL UNFRAMED PLYWOOD PANEL EDGES AND NAIL WITH EDGE NAILING SPECIFIED. Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com Project Contact Todd Fisher tel 206 413 6671 tfisher@harriottvalentine.com Designer Aaron Dupont akd.archdesign@gmail.com 206 348 4483 Project Cooper Deck 1125 Olympic Ave. Edmonds, WA 98020 Issue Date Issue Description 9/23/22 Permit Building Department Approval Drawing Title GENERAL STRUCTURAL NOTES Drawing Number S100 REST Oct 27 2 CITY OF EDM( DEVELOPMENT S DEPARTME U w 0 N N w IZ 0 U HVE 10"0 PLINTH, REINF. WITH COLUMN PER PLAN (4) #4 VERT. AND TIES (PRESSURE —TREATED) #3x0 @YOC �-- CB SERIES POST BASE (4) #4 EACH WAY II II L J inm���Ic�IR.�l�:a]�� DTT1Z OTHER CONFIGURATIONS AVAILABLE. CONSULT WITH ENGINEER OF RECORD FOR INSTALLATION TO DIFFERENT CONDITIONS PT LEDGER OR BEAM PER PLAN EX. MASONRY Lr) 3/4" = V-0" SEE 4/S2.1 FOR CALLOUTS IN COMMON SDWH TIMBER —HEX HDG 3" THREAD PENETRATION 2 EXISTING 6" CONCRETE STEM WALL W/ 12" WIDE CONCRETE FOOTING. CONTRACTOR TO VERIFY AND REPORT TO STRUCTURAL ENGINEER OF RECORD PRIOR TO CONSTRUCTION e 0 LEGEND SPAN EXTENT X SECTION DETAIL X. (FB) FLUSH BEAM (PT) PRESSURE -TREATED (KP) KING POST (UNO) UNLESS NOTED OTHERWISE COLUMN ABOVE ❑ COLUMN BELOW NEW STRUCTURAL WALL EXISTING STRUCTURAL WALL NEW CONCRETE FOOTING EXISTING CONCRETE WALL (SYM.) SYMMETRICAL NOTE!! EXISTING FRAMING MEMBERS AS INDICATED ON THIS PLAN ARE ASSUMED FOR DESIGN PURPOSES ONLY. HARRIOTT VALENTINE ENGINEERS SHALL NOT BE HELD LIABLE FOR LOCATION/ SIZE OF EXISTING MEMBERS AS CALLED ON THIS PLAN. EXISTING MEMBERS SHALL BE VERIFIED AND REPORTED TO STRUCTURAL ENGINEER OF RECORD PRIOR TO CONSTRUCTION. FOUNDATION PLAN NOTES 1. WHERE NEW CONCRETE WALLS OR FOOTING ABUT EX. CONCRETE, PROVIDE DOWELS #4 x 2'-0" TO MATCH HORIZ. REINFORCING, EMBED 5" IN EPDXY GROUT. Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com 9126122 Project Contact Todd Fisher tel 206 413 6671 tfisher@harriottvalentine.com Designer Aaron Dupont akd.archdesign@gmail.com 206 348 4483 Project 1-1/2" = 11— 0„ 0 I I .. Cooper Deck 1125 Olympic Ave. . Edmonds, WA 98020 3/4" = 1'-0" 4 1 FOUNDATION PLAN 52.0 scale: 1/4" = 1'-0" Issue Date Issue Description 9/23/22 Permit Building Department Approval Drawing Title FOUNDATION PLAN Drawing Number SIO REST Oct 27 2 CITY OF EDM( DEVELOPMENT S DEPARTME V 0 w 0 N w 0- O U HVE LEGEND Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 SPAN Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com �e EXTENT X X. SECTION DETAIL (FB) FLUSH BEAM 2x BLOCKING JOISTS PER PLAN +6 3 (PT) PRESSURE —TREATED S2. ,\ J ash, (KP) KING POST 2x6 (PT) PLATE - 6 o < (UNO) UNLESS NOTED OTHERWISE ° S2.1 a 1' COLUMN ABOVE (2) H2.5AZ X5/8"0 x 6" a JOISTS PER PLAN WITH AT HOLDOWN 2 0 ❑ COLUMN BELOW BEAM PER PLAN TITEN = CONC. WALL HANGERS PER SCHEDULE TITEN HD (STAINLESS STEEL) NEW STRUCTURAL WALL @ 24" oc a X `0 W w EXISTING STRUCTURAL WALL ° J EX. CONC. WALL 3 X cV NEW CONCRETE FOOTING PER PLAN ° a S2.1 AT HOLDOWN 3 2.0 EXISTING CONCRETE WALL LJ 7 (SYM.) SYMMETRICAL 3/4" = 1'-0$$ 2 3/4" = 1'-0" \ 2 S2. NO WORK AT INTERIOR OF EX. HOUSE fV � 51„ GD AT HOLDOWN 3 2.0 X 4x4 (P.T.) STANCHIONS DTT2Z TOP AND BOTTOM BEAM PER PLAN 21" 4) 5/8"0 BOLTS EX NOTE!! EXISTING FRAMING MEMBERS AS INDICATED ON THIS PLAN ARE ASSUMED FOR DESIGN PURPOSES ONLY. HARRIOTT VALENTINE ENGINEERS SEE ARCH'L. FOR LAYOUT EACH WITH 1/2"� THRU- 1° @ 16"oc W SHALL NOT BE HELD LIABLE FOR LOCATION/ SIZE OF EXISTING MEMBERS BOLT TO STANCHIONS AND BOLTS - 7 s21 AS CALLED ON THIS PLAN. EXISTING MEMBERS SHALL BE VERIFIED AND � (8) 1/4"x11/2" SDS SCREWS � BEAM '"�' REPORTED TO STRUCTURAL ENGINEER OF RECORD PRIOR TO CONSTRUCTION. SEE ARCH'L. FOR INFILL, TO BLOCKING � 2x12 PT (� 20„ oc TOP AND BOTTOM RAILS ° ° PL 1/4" EACH SIDE OF AT HOLDOWN 3 HANGER SCHEDULE , x ° UNLESS NOTED OTHERWISE, E° o ®® �� EPC6Z Q �� r MEMBER AT TOP AND �, 2.o MEMBER HANGER FACE NAILING CAPACITYQ ws r PROVIDE THE FOLLOWING 0 ° ®°, �� BOTTOM OF KNEE BRACE (FLAT ONLY) (Cd = 1.0) 4 AT A MINIMUM: (5) 16d ° \s� BETWEEN HOEDOWNS 4 S2. 2x10 or 2x12 LUS210 10d COMMON 1335 lb �' � 2x6 RAIL CAP, AND 2x4 Ezo ® ° ® °®° \ o TOP AND BOTTOM RAILS, 0 6x6 (PT) KNEE 7 AT HOLDOWN 2'-0ncxn� WITH A MAXIMUM SPAN 0BRACE 52.1 MAX. 9126122 OF 6'-0"oc, ATTACH EACH WITH (2) N0. 8 WOOD BLOCK ONE BAY FULL DEPTH WITH (2) 2x \ '� POST PER PLAN ¢ 3 Project Contact Todd Fisher SCREWS EACH END (MIN.) (AT JOISTS PARALLEL p��, 6x12 (PT) (FB) ,�,� � tel her@ha206 413 6671 tfisher@harriottvalentine.com CONDITION, SHOWN) ����P 11 3 AT HOLDOWN 3 AT nvLuvrrly * 2x2 PICKETS @ 4"oc, ATTACH OR PROVIDE 2x BACKER 30 3 0 2.0 2.0 EACH WITH (1) NO. 8 WOOD 16" LONG (AT JOISTS 2'-0' 10 Designer SCREW TOP AND BOTTOM PERPENDICULAR CONDITION, X MAX. 3.o Aaron Dupont akd.archdesign@gmail.com SIMILAR) k S2 206 348 4483 END —OF —BEAM KNEE BRACE 6 `V X 2x12 PT @16oc Project 1-1/2" = 1 ' — 0" 3 3 /43' = 1 ' — 0" S2.1 Cooper Deck EX. 8" CONC. WALL 1125 Olympic Ave. CONTRACTOR TO FIELD —VERIFY Edmonds, WA 98020 3 AND REPORT TO STRUCTURAL S2. ENGINEER OF RECORD PRIOR TO CONSTRUCTION Issue Date Issue Description 9/23/22 Permit EX. MASONRY SEE 6/S2.1 FOR CALLOUTS IN COMMON AC6Z BLVZ (BRICK VENEER LEDGER CONNECTOR) CONTINUOUS FLASHING @ 12" oc 12" MAXIMUM El WITH DRIP EDGE (COORD. ° ° DISTANCE FROM ENDS OF WITH ARCHITECTURAL) . LEDGER 771 Building Department Approval 0 0 0 0 1 DECK FRAMING PLAN EX. JOISTS (MUST BE 0 0 s2.1 scale: 1/4" _ 1'-0" PERPENDICULAR TO RIM) \S� DECK JOISTS PER PLAN WITH HANGERS Drawing Title PER SCHEDULE DECK FRAMING PLAN SYM. LEDGER PER PLAN Drawing Number BLVZ — INTERIOR JOISTS PERPENDICULAR MIDDLE —OF —DECK KNEE BRACE S2ml ), , 1-1 /2 = 1 —0 4 3/4 = 1 —0 REST Oct 27 2 CITY OF EDM( DEVELOPMENT S DEPARTME Y 0 w N0 N w 12 0 0 HVE Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com 3/4" = 1'-0" 1 3/4" = 1'-0" 2 3/4" = 1'-0" 3 3/4" = 1'-0" 4 29049 c� �cxn� 9126122 Project Contact Todd Fisher tel 206 413 6671 tfisher@harriottvalentine.com Designer Aaron Dupont akd.archdesign@gmail.com 206 348 4483 3/4" = 1'-0" 5 3/4" = 1'-0" 6 3/4" = 1'-0" 7 3/4" = 1'-0" QProject Cooper Deck 1125 Olympic Ave. Edmonds, WA 98020 Issue Date Issue Description 9/23/22 Permit SECTION ELEVATION BEAM PER PLAN L-T\„ 54„f 2 Ili" (2) 1/2"0 BOLTS NOTCH BOTTOM OF BEAM AT INTERSECTION 7 Tr COUNTERSINK TOP OF BEAM (2) LOCATIONS (2) 2 /2" PLATE WASHERS JOISTS PER PLAN—\ (BEYOND) BEAM PER PLAN Building Department Approval L4x4x'/4 0 o II II II II 5„ (2) BENT PL 1/4" DAP END OF 6x12 BEAM FOR BEARING /4"± AS DAP END OF 6x12 BEAM FOR a (4)/$"0 BOLTS U' ° EQUIRED BEARING 1/4"± AS REQUIRED d �� i2" 32" 32„ MIN. �BOLT (2) A35 — (1) EACH A35 5/8"0 x 6" TITEN HD (STAINLESS STEEL) a d � TITEN � = � CONC. WALL BEAM PER PLAN (HANGS FROM BEAM TO END OF DROP sz„ BEAM SIDE OF BEAM \ \�� —DROPPED BEAM PER PLAN Drawing Title STRUCTURAL DETAILS ad EX. CONC. WALL RUNNING AGAINST EX. MASONRY EXT. WALL AT HOUSE) Drawing Number 3/4„ = 1 —0 9 3/4 = " 1 —0 1 \ ), 3/4 = 1 —0 11 3/4 = 1 —0" 12 SIO REST Oct 27 2 CITY OF EDM( DEVELOPMENT S DEPARTME Y w w IZ 0 U