APPROVED BLD2021-0520+Letter_fron_Arch+1.6.2022_3.03.22_PM+2607748REVISION Jan 06 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT January 5, 2022 Kyle Jones Senior Project Manager Ameresco Inc 222 Williams Ave South, Suite 100 Renton, WA 98057 Dear Kyle: BLD2021-0520 AMMR - FOR STEEP STAIRS ■ See AMMR Request Form for approval by 1 L. Bjorback 1 /28/2022 1 ' City of Edmonds ■ Building Division 1 K PUX Interdisciplinary Design 3131 Elliott Avenue Suite 400 Scattic, .AJA 98121 P 1206.286.1640 www.kpg.com ■ Revised plan sheets ; include A-4, A-5, A-7, 1 A-8, A-9. ' Plans for renovations at the Edmonds WWTP include a new stair system between the utilidor landing and the new upper floor level. There is a 138" (11'-6") vertical distance between those levels. Current approved plans for that area show an alternating tread stair. The stair is shown on pages A-4, A-5, and A-7 in the approved construction drawings. The horizontal space available for a stair run is very limited at this location. Large equipment sizes, specific connection requirements, and existing and new structural elements constricts the useable space. Plan views of the levels in questions are shown below. j ENE F's�A' NNIN� �; r � I �oe�x ai wEuv� I kI I D 71A-8 NEWSTAIR ?#4 M1 I NEW FLOO OPENING F, NE 5 AIR K2 2 NEW ALTERNATING Art � —8 TREAD STAIR #24 OPENIN BOVE Ill_PP? 4'.2• �J I y r I EX 6ASEME i FLOOR — 9' SOLIDS HANDLING RO � Lr FF +18.31' + New Upper Floor at Alt Tread stair Utilidor Platform at base of Alt Tread stair An initial version of this design showed a steep stair between these floors (8-5/8" risers and 10-3/8" treads). This stair was flagged as non -compliant during plan review. In the final for - construction drawings, an alternating tread stair was shown. An alternating tread stair is a code - compliant means of allowing a steeper ascent angle per IBC 1011.14. The alternating tread stair had individual risers of 7-1/4" and treads offset 5", for an effective riser height of 14-1/2" and an effective tread depth of 10". Section views of these two different stairs are shown below. Proposed Steep stair g. STMR µ ' I I I � 1 I I I L I 1 � I iBTR L-� Current approved Alternating tread stair The stair in question provides a convenient means for staff to traverse between the utilidor and solids handling floor levels, occasionally carrying tools or parts for equipment. Staff and management at the WWTP are concerned about the practicality of the alternating tread design. They can be challenging to learn how to use them. Hand -carrying items interferes with proper use of the handrails. Staff and management would both prefer a steep stair at this location. This AMMR is for a code exemption for a steeper than the IBC 7" maximum riser height in lieu of an alternating tread stair or ladder. The reasoning to limit riser heights comes from several factors. Steeper stairs are more difficult to traverse, slowing travel speeds in an emergency. Overly tall stair risers are physically challenging for some occupants, further reducing travel speed and increasing the odds of a fall. As the number of occupants goes down, and the mobility of those occupants remains high, it can be considered safe to allow steeper stair runs. One example of steeper stairs allowed is in the OSHA regulations covering stairs used to access equipment and work platforms. OSHA chapter 19.25 regulates the construction of stairways used for these purposes. See OSHA Regs here Those regulations allow for a steeper, narrower stairs with less hand and guardrails because of the low occupant counts and their better -than -minimal mobility. Given the low load and reasonable mobility of the occupants in this space, it is reasonable to compare this exiting situation to the equipment access stairs under OSHA regulations. This proposed steep stair at this location will meet all OSHA rules for stairs, providing an acceptable level of safety. There are several factors that make this modification NOT reduce occupant safety: 1- This is a second exit from the space in question. IBC 1006.2.2.1 requires two exits from incinerator rooms. One of those exits is allowed to be a fixed ladder or alternating tread stair. The proposed steep stair will be only one of the two required exits. There will remain a fully IBC -compliant stair in the NE corner of the basement that will accommodate typical day-to-day travel. 2- There is a very low occupant load in this area. Occupant loading per IBC Table 1004.5 is 7 for each floor. Such a low occupant load reduces the chance of overloading and crowding this part of the exit system. 3- There are no members of the unaccompanied public here. Only trained staff will be traversing this area. Having occupants familiar with this facility reduces the chance of dis-orientation during an emergency. Attached are revised drawing sheets from the April permitting set showing the proposed steep stairs. A-4 shows the lower landing, A-5 shows the upper level and stair plan, and A-7 shows the stair in section. The stair is shown clouded in blue on all sheets. Upon approval of this AMMR, these changes would be incorporated into the construction documents and used as a basis for final detailing and approval of the stairs in question. Based on the above, it is this architect's professional opinion that allowing the installation of a steeper stair at this location complies with the intent of the building code. A steep stair meeting OSHA standards will not adversely impact occupants' ability to exit the building nor unacceptably reduce the safety of the exiting system. Please contact me if you have any questions or feedback. I look forward to your favorable reply. Yours, X),� 4,� �, Bryan Schutt, Architect KPG WA license number 12404 Enclosure: 3 drawing sheets