Loading...
REVIEWED BLD2021-0520+Interior_Lighting_Summary+4.12.2021_9.32.48_AM+2139725Firefox https://waenergycodes.com/print_project summary_f6nn.php?k=aWQ... BLD2021-0520 RECEIVED LIGHTING COMPLIANCE SUMMARY DESE E1PMEN3ER�VCES 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: 02021 NEEA, All rights reserved Project & Applicant Information Project Title Edmonds WWTP - 2018 WSEC For Building Department Use: Date' Apr 02, 2021 Project Address 200 2nd AVE S Edmonds, WA 98020 Applicant Name Marcus Eidal Applicant Phone 206-200-5211 Applicant Email Meidal@ameresco.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Utility/Equip, Building Cond. 4,126 Use Type Other Floor Area New Building Project Cond. Floor 4,126 or Alteration Interior Lighting Area Floors Above Grade 1 General Project Types Alteration Addition Lighting Exterior Lighting Compliance Method Compliance Method 1 Lighting Scope Scope - General This project includes replacements of existing fixtures with LED fixtures. All revised interior fixtures are sealed for (NEC 500) Lighting Project Description Class II, Division 2 hazardous environment. Existing fixtures are 2 x 32W T8 to be replaced with 37W/fixture. Exterior fixtures provide task lighting for modified process areas for new equipment. Project Interior / Exterior Luminaire Replacement Compliance LPA Calculation Compliance Lighting Compliance YP Type (Interior includes both interior & parking)P Scope Method Adjustment J Verification Scope and Method Alteration Interior Lighting 50% or more replaced Building area No Calculation Adjustments allowed J COMPLIES Alteration Exterior Lighting less than 50% replaced Not applicable to exterior COMPLIES Additional Efficiency Options Included Project Title Edmonds WWTP - 2018 WSEC Date Apr 02, 2021 Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more Compliance COMPLIES replaced) Verification Compliance Method Building area LPA Calculation Adjustment none Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed Total Proposed Watts Compliance Status by (SF x LPA x 1) By Building Area Building Area Manufacturing facility 1 4,126 1 0.82 1 3,383 1,275 COMPLIES Proposed Lighting Power Density Watts per Total Watts Fixture Fixture New or Quantity of Fixtures, CLDs Fixture, CLD or Total Watts per Proposed Type/Application ID Building Area Existing -to- or I Linear Linear (#F x WpF) Remain Luminaires (#F) (WpF�Ce Feet (LF) Foot (WpLF) or (LF x WpLF) Individual Fixtures Troffer XP2 Manufacturing New 51 25 1,275 facility Project Title Edmonds WWTP - 2018 WSEC Date Apr 02, 2021 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (50% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing -to -Remain Individual Fixtures Troffer XP2 E-9, E-11,E-12 LED Manufacturing facility New Fixture Description: Sealed, Classified Area Linear FIxture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Project Title Edmonds WWTP - 2018 WSEC Date Apr 02, 2021 Lighting Power Calculation ALTERATION - EXTERIOR LIGHTING (less than 50% Compliance COMPLIES replaced) Verification Exterior Lighting Power Allowance Category Tradable and Non -Tradable Categories Existing Lighting -Wattage Prior to Alteration Total Watts Allowed Total Proposed Watts Compliance Status Existing Lighting Building entrances and exits 350 350 Existing Lighting Building grounds 5,150 5,150 1 of 2 4/2/2021, 6:09 AM Firefox Ri=r-FniFn https://waenergycodes.com/print_project summary_f6nn.php?k=aWQ... Proposed Exterior Lighting Pow Spaces with less than 50% fixtures replaced CItt OFE-01IDS OEVELOPMENTSE Quantity of VICES Watts per Total Watts Fixture Type Fixture ID Tradable and New or DE- ­Fixtures Fixture, CLD or Total Linear Watts per Linear Proposed Non -Tradable Categories Existing -to -Remain CLDs or Luminaire (WpF) Feet (LF) Foot (WpLF) (#F x WpF) or Luminaires (#F) (LF x WpLF) Individual Fixtures Wall -mounted GG New 3 59 177 Wall -mounted HH New 4 43 1 1 1 172 Proposed Total LPD 1 349 Project Title Edmonds WWTP - 2018 WSEC Date Apr 02, 2021 Proposed Fixtures Details ALTERATION - EXTERIOR LIGHTING (less than 50% replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type Tradable and Non -Tradable Categories New or Existing -to -Remain Individual Fixtures Wall -mounted GG E-4, E-8 LED New Fixture Description: Hazardous Area, Wall Pack Photoeye Wall -mounted HH I E-4, E-8 LED New Fixture Description: Normal Area, Exterior Wall pack with photoeye control 2 of 2 4/2/2021, 6:09 AM