Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED ENG PLN BLD FIR RESUB1 BLD2023-0750+Architectural_or_Building_Floor_Plans+8.2.2023_5.10.24_PM+3704275
GENERAL NOTES PROJECT INFORMATION Nova Family Resource 4,!!� 1. THIS SET REPRESENTS "THE PERMIT DRAWINGS" AND IS PROJECT ADDRESS: 21010 76TH AVENUE WEST, 1 INTENDED TO SHOW MINIMUM REQUIREMENTS. IT IS THE EDMONDS, WA 98026 N RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL CONSTRUCTION NECESSARY FOR THE COMPLETE INSTALLATION BUILDING OWNER: KIM CHAN c OF ALL OPERATING SYSTEMS, MATERIALS AND FINISHES IN Kim.chan@docpro.com ACCORDANCE WITH MFR.'S RECOMMENDATION. CONTRACTOR and SHALL THOROUGHLY REVIEW DRAWINGS AND OWNER'S PROPERTY MANAGER: HENRY YUEN REQUIREMENTS. (AGENT REPRESENTATIVE) P.O. BOX 524 2. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING KIRKLAND, WA 98083 DIMENSIONS PRIOR TO BID. DISCREPANCIES IN DIMENSIONS, 0 (206) 618-4631 DRAWINGS, GRAPHIC REPRESENTATION AND ACTUAL FIELD henry@pnwholding.com MEASUREMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CLIENT. Chi ldcare Center TENANT APPLICANT: NOVA FAMILY RESOURCE 3. CONSTRUCTION SHALL BE BASED ON THE LOCAL JURISDICTION and CHILDCARE CENTER APPROVED PLANS AND CLIENT'S COMMENTS. THE APPROVED CAROLE HARPER PLANS ARE TO REMAIN ON SITE AT ALL TIMES FOR USE BY (425) 214-2493 ALL INVOLVED TRADES AND INSPECTORS. caroleh@novafam.org 4. THIS SET OF DRAWINGS SHALL NOT BE COPIED IN WHOLE OR PEYTON FOSTER IN PART WITHOUT PRIOR WRITTEN CONSENT FROM THE CLIENT. (509) 306-2455 THIS DOCUMENT IS CONSIDERED AS ONE UNIT AND SHALL NOT Conditional Use & Remodel Permit peytonf@novafam.org BE CONSIDERED COMPLETE OR WHOLE IF DOCUMENTS ARE SEPARATED IN ANY MANNER. DOCUMENTS SHALL NOT BE AUTHORIZED AGENT: dwudesign SEPARATED FOR THE PURPOSES OF SUBMITTING PROPOSALS (DURING PERMIT) DAVID WU OR FOR SEPARATE PHASES OF CONSTRUCTION. For Change of Use to Childcare 14632 14TH AVENUE SE 5. THESE DOCUMENTS ARE PREPARED FOR USE BY THE MILL CREEK, WA 98012 CONTRACTOR AND IN NO WAY, EITHER IN WHOLE OR IN PART (425) 512-1780 CONSTITUTE ANY DIRECTION OR INSTRUCTION TO ANY A CUP & P g L dwudesign@gmail.com CONTRACTOR WITH REGARD TO CONSTRUCTION METHODS, Separate arkin ot Permit MEANS OR TECHNIQUES. LEGAL DESCRIPTION: WILLOWDALE GARDENS 6. CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION WORK DIV 1 BLK 000 D-04 — INCLUDING, BUT NOT LIMITED TO, SEQUENCE & TEMPORARY 11 b fm t 0 S 50 FT OF N 176 FT OF SHORING OF ALL EXISTING STRUCTURES & VERIFICATION OF LOT 16 EXISTING UTILITIES & SERVICES. W1 e applied after Staff Con irma ion 7. CONTRACTOR SHALL NOTIFY UTILITY COMPANIES PRIOR TO SNOHOMISH COUNTY PARCEL TAX IDS: 00614300001604 COMMENCEMENT OF ALL WORK. THE CONTRACTOR IS ■ RESPONSIBLE FOR REPAIRS, SUBJECT TO LOCAL JURISDICTION AND UTILITY INSPECTOR'S FINAL APPROVAL. of Parking Proposal ABBREVIATION LAND USE AND BUILDING CODE INFORMATION DRAWING INDEX PROJECT DESCRIPTION A.C.T. ACOUSTICAL CLG TILE LAV. LAVATORY JURISDICTION: CITY OF EDMONDS PER 2008 APPROVED PERMIT, THIS BUILDING WAS PF ADJ. ADJUSTABLE L.F. LINEAR FOOT/FEET A-1 PROJECT INFORMATION, PROJECT PERMITTED FOR THE USE AS 'PROFESSIONAL OFFICES'. P1 A.F.F. ABOVE FINISHED FLOOR MTL. METAL DESCRIPTION, CODE INFORMATION, I BLK'G BLOCKING ADOPTED STATE CODE: THE CITY OF EDMONDS ENFORCES THE FOLLOWING DRAWING INDEX GENERAL NOTES C.L. CENTERLINE/CLEARANCE MAT'L MATERIAL MECH. MECHANICAL WASH NGTON STATE BUILDING CODES AND AMENDMENTS; ABBREVIATION & VICINITY MAP NEW TENANT USE AS 'NOVA FAMILY RESOURCE and MFR. MANUFACTURER CLR. CLEAR THE WASH NGTON ADMINISTRATIVE CODE CHILDCARE CENTER'. CLG. CEILING MIN. MINIMUM 08-10-2023 (WAC) TITLE 51 AND AS AMENDED BY THE EDMONDS MUNICIPAL A-2 SITE PLAN DETAILS & PARKING LOWER FLOOR 721 SF TO BE USED FOR CHILDCARE, PLAN REVIEW: ANALYSIS FOSTER CHILDREN IN THE AREA. THE REST REMAINS C.M.D. COAL MONOXIDE DETECTOR M.R. MOISTURE RESISTANT APPROVED WITH CONDITION: CODE TITLE 1 5: THE SAME USE, NO CHANGE. C. M . U . MASONRY UNIT 1. A MONITORED FIRE ALARM SYSTEM REQUIRED N/A NOT APPLICABLE 3FOR .ASEP SEPARATE IT IS RPER EQUIRED 19.25.03FIR 2018 WASH NGTON STATE ENERGY CODE(LIGHTING ALLOWANCE A-3 EXISTING UPPER FLOOR PLAN, NO UPPER FLOOR TO BE USED FOR OFFICES, NO CHANGE. ALACOL. COLUMN N. I. C. NOTIN CONTRACT 3. A SEPARATE PERMIT IS REQUIRED FOR THE FIRE ) CONC/# . CONCRETE NO NUMBER E PRLA ATON: 2018 INTERNATIONAL BUILDING CODE (IBC) WORK, PROJECT AREA PROPOSED CONT. CONTINUOUS ECDC REFERS TO THE IEBC IN REGARD TO LOWER FLOOR PLAN NO EXTERIOR WORK, INTERIOR REMODEL ONLY. N.T.S. NOT TO SCALE CHANGE OF USE OF AN OCCUPANCY. IEBC REFERS 2018 INTERNATIONAL EXISTING BUILDING CODE NO EXISTING STRUCTURAL WALLS WILL BE DISTURBED. CON ST. CONSTRUCTION 0. A. OVERALL TO IFC. REVISIONS LOCATED IN CHAPTER 19.25 OF THE ECDC ARE CONSIDERED REVISED IFC 2018 INTERNATIONAL FIRE CODE A-4 EXITING DIAGRAM, MINIMUM PLUMBING PREPARE PARKING AREA PER LAND USE APPROVAL. F CPT. CARPET 0. C. ON CENTER LANGUAGE WHICH LESSENS THE SQUARE DIET. DETAIL FOOTAGE REQUIRING FIRE PROTECTION SYSTEM 2018INTERNATIONAL MECHANICAL CODE OCCUPANT LOAD CALCULATIONS 0. H . OVERHANG FROM WHAT THE IFC STATES. BECAUSE THIS DIM. DIMENSION P—LAM PLASTIC LAMINATE BUILDING IS OVER 3000 SQ FEET AND THERE IS A 2018 INTERNATIONAL PROPERTY MAINTENANCE CODE DEFERRED SUBMITTAL: MECHANICAL/ELECTRICAL/ C PROPOSED CHANGE OF USE A MONITORED FIRE A-5 REFLECTED CEILING PLAN 2018 PLUMBING UNDER SEPARATE PERMIT BY LICENSED DWG. DRAWING P.L. PROPERTY LINE ALARM SYSTEM IS REQUIRED BUT NOT AFIRE 2018 INTERNATIONAL PLUMBING CODE ELEC. ELECTRICAL P.T. PRESSURE TREATED SPRINKLER SYSTEM. WASHINGTON STATE ENERGY CODE CONTRACTORS. SIGNAGE BY SIGN COMPANY. 0 DFM BURT EQ. EQUAL PTD. PAINTED RM 2.4 Approved LIGHTING ALLOWANCE WORKSHEET A DOHS SYSTEM IS REQUIRED FOR MECHANICAL PERMIT ZONING: F.A.R. FLOOR AREA RATIO R.C.P. REELECTED CLG. PLAN DFM chrisUutt F.E. FIRE EXTINGUISHER REF. REFRIGERATOR South County Fire A-6 ENLARGED RESTROOM FLOOR PLAN �c F.F. FINISHED FLOOR REINF. REINFORCED CONSTRUCTION TYPE: V—B Date:08/10/2023 DETAILS VICINITY MAP F.0.1.C. FURN. BY OWNER REQ'D. REQUIRED INSTALLED BY REV. REVISED/REVISION OCCUPANCY: FORMER & PROPOSED 'B' THAN 50 OCCUPANTS A-7 ARCH DETAILS TIN SUBJECTCONTRACTOR SHED. SCHEDULE (LESS ) � A-8 ARCH DETAILS TO ELD = _ F.0.1.0. FURN. BY OWNER S.D. SMOKE DETECTOR S ON FOR INSTALLED BY OWNER S.F. SQUARE FOOT/FEET OCCUPANT FACTOR: CHILD CARE 35 SF NET PER PERSON, OFFICE 100 SF PER PERSON F.R.P. FIRE RATED PANEL S.G. SAFETY GLASS INPATIENT TREATMENT AREA 240 SF PER PERSON FT. FOOT/FEET SIM. SIMILAR ACCESSORY STORAGE 300 SF GROSS PER PERSON FURN. FURNISHED S.O.G. SLAB ON GRADE F.V. FIELD VERIFY SQ. SQUARE GROSS LOT SIZE: 0.16 ACRE GA. GAUGE SUSP. SUSPENDED G.C. GENERAL CONTRACTOR S.V. SHEET VINYL G.W.B. GYPSUM WALL BOARD TEMP. TEMPERED TOTAL BUILDING AREA: 4,063 SF (1,997 SF -LOWER FLOOR, 2,066 SF -UPPER FLOOR HDWR. HARDWARE T.O. TOP OF H.M. HOLLOW METAL TYP. TYPICAL PROJECT AREA: UPPER FLOOR - NO CHANGE N. INCH U.O.N. UNLESS OTHERWISE NOTED LOWER FLOOR - ONLY ONE ROOM 721 SF TO CHILDCARE, OTHER City Of Edmonds Building Department Work CHANGE OF USE Address 21010 76TH AVE W Owner NOVA CHILDCARE Approved Date 08/17/2023 Building Official ff rI & Permit Number BLD2023-0750 CODPMPLIANCE D D = m m APPROVED z z F m m PLANS MUST BE � m ON JP��SI"i�A � Cl') - OBTAIN ELECTRICAL PERMIT FROM STATE L4PPF 4TREEI S� III 111 UUJ 1 RICJ � 4632 - 14th Ave. SE 1 i I I Creek, WA 98012 425) 512-1780 wudesign@gmail.com PROJECT: Vova Family Resource and Childcare Center Conditional Use & Remodel Permit LOCATION: 21010 76th Ave. W. Edmonds, WA 98026 PERMIT PLAN SET :OJECT INFORMATION ZOJECT DESCRIPTION ODE INFORMATION DRAWING INDEX GENERAL NOTES ABBREVIATION VICINITY MAP [LE: 2023-011 ATE: 06/ 15/2023 REPARED BY: D. Wu ENGINEERING DIVISION APPROVED AS NOTED jdj tV4a ,,mt 10/23/2023 VIV 4PPROVED BY PLANNING Oct 19 2023 ;EVISIONS: 1�CITY COMMENT CON OCC OCC TRUCTION TYPE v PANCY GROUP E PANT LOAD 0 INST. INSTALL V.C.T. VINYL COMPOSITION TILE AREAS REMAIN THE SAME USE INSUL. INSULATION VTO VENT TO OUTSIDE 7 RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NUMBER: Aml ACCESSIBLE PARKING LOGO NOT TO SCALE 9„ 3" 6" PRE -CAST CONCRETE CURB v. a PAVED PARKING 4 d bl a IP d CRUSHED ROCK 6 x 18" @4'-0" o.c. U 2 TYP. EA STOP) CONCRETE WHEEL STOP NOT TO SCALE 2" RADIUS TYP. @ CORNERS 1 /2" DIA. LAG SCREWS 2-1/2" HEIGHT LETTERING ON CONTRASTING BACKGROUND INTERNATIONAL SYMBOL OF ACCESS-- 8,X 8 DIM 1 /2" WIDE STRIPE 1" HEIGHT LETTERING ON CONTRASTING BACKGROUND RESERVED -PARKING STATE DISABLED PARKING PERMIT REQUIRED VAN ACCESSIBLE 5' — 0" TO FIN. GRADE ACCESSIBLE PARKING SIGN NOT TO SCALE vo4 �. 5 - 3 JOINT USE PARKING LOCATION 0 or t - -11 4- - EGRESS PATHWAY LOCATION w � r or 76TH AVENUE WEST'( \, PROJECT LOCATION LANDSCAPING REQUIREMENTS: Di TYPE III LANDSCAPING ON THE NORTH, WEST AND SOUTH SIDES YP IV LAND C PING N TH E E ST I C. Type III andscaping. Type III landscaping is ' nded to provide visual separation of uses from streets, and visual separation of compatible uses so as to soften the appearance of streets, parking areas and building elevations. 1. Evergreen and deciduous trees, with no more than 50 percent being deciduous, a minimum of six ROOM NAME feet in height, and planted at intervals no greater than 30 feet on center; and 2. If planted to buffer a building elevation, shrubs, a minimum of three and one—half feet in height, and livin round cover lanted so that the round will be covered within three ears; or g g P g 3. If planted to buffer a parking area, access, or site development other than y a building, any of the UPPER FLOOR OFFICE following alternatives may be used unless otherwise noted: a. Shrubs, a minimum of three and one—half feet in height, and living ground cover must be UPPER FLOOR GENERAL planted so that the ground will be covered within three years. b. Earth mounding, an average of three and one—half feet in height, planted with shrubs or living ground cover so that the ground will be covered within three years. This alternative may not be used in a downtown or waterfront area. OFFICE OF CONSULTATION P L�O�AL: c. A combination of earth mounding, opaque fences and shrubs to produce a three and one—half feet in height. D. Type IV Landscaping. Type IV landscaping is intended to provide visual relief visual barrier at least where clear sight is SOWER FLOOR CHILDCARE LOWER FLOOR OFFICE desired to see signage or into adjacent space for safety concerns. 1. Trees shall be deciduous and planted 25 feet on center and the trunk shall be free of branches LOWER FLOOR STORAGE below six feet in height. 2. Plant materials which will cover the ground within three years, and which will not exceed three and one—half feet in height. LOWER FLOOR TOTAL: 39'-5" (EXISTING BUILDING FIELD VERIFY) PROPERTY LINE 50'-0" TYPE III LANDSCAPING DWESTSIDE,Z�L EXISTING REAR YARD, NO WORK REFER TO REQUIREMEN 50'-0" (EXISTING BUILDING, FIELD VERIFY) EXISTING 2 STORY BUILDING PROJECT AREA: LOWER FLOOR ONLY NO WORK ON UPPER FLOOR (REMAIN AS OFFICE FOR NOVA) NO WORK ON EXTERIOR OR STRUCTURAL Rear yard not to used for childcare unless an exit and path are provided to the public way. 0 w z L0 0 o' LL_ Q EXISTING PRESTIGE POST ACUTE AND REHAB CENTER Cn BUILDING & PARKING AREA w o' c� w 0 0 W 4' EXISTING CONC. WALKWAY SPECIAL PAVING W CI CLEARANCE AREA 4'-0" Ln W v .W EGRESS O INTERNATIONAL SYMBOL( ' W 18 -0 • W (PATHWAY OF HANDICAPPED PARKING ACCESSIBLE FROM SIGN MOUNTED 5-0" ABOVE ' W 2 VAN . W NORTH FINISHED GRADE ON METAL POST STALL NEIGHBOR W #1 W W . W ' 24'-0" PROVIDED W W rTYPELANDSCAPING ' 18'-0" MIN. REQUIRED FOR ' I TYPE III LANDSCAPING REGULAR - 2-WAY TRAFFIC SOUTH SIDE, ' y o ' y ON NORTH SIDE, REFER TO y 2 STALL i �•y REFER TO REQUIREMENT W #2 rn REQUIREMENT 16'-04'-0" W W " � W REGULAR LANDSCAPE W W W y l - - W 2 STALL CDi 4'-0" W #3 LANDSCAP W REGULAR - CD STALL NOTES: z #4 0-) W EXISTING PAVED 1. PER DRC2023-0023, OUT OF THE 4,036 SF OF EXISTING .W PARKING REGULAR REK' TRIPPED.W LEASING BUILDING SPACE, 3,044 SF USED AS CHILD EXISTING ONE STORY NEIGHBOR 2 STALL �i LANDSCAPING CARE AND ASSOCIATED USE, AND 1,019 SF USED AS COMMERCIAL BUILDING PARKING . -.I #5 � PER PLAN FOR CODE 'W USE - OFFICE & HAIRCUT & I .W COMPLIANCE PARKING .'W I OFFICE SPACE NOT PROVIDING ON —SITE CUSTOMER DRIVEWAY W STALLS SERVICE. THEREFORE, PER ECDC 17.50.020(C)(8), W W REGULAR - .W .W z STALLCD .W 10 STALLS FOR CHILDCARE USE AND 1 PARKING STALL W. #6 W W _ FOR OFFICE USE NOT PROVIDING ON —SITE CUSTOMER � I' W I W W W I o SERVICE, PER ECDC 17.50.020(B)(6). In REGULAR - .W. In In z STALL �i Liy #7 °' .y z 2. 8 STALLS PROVIDED ON SUBJECT PROPERTY: z W J (1) ACCESSIBLE VAN PARKING STALL >_ I WW I REGULAR CD.W I 11 —0 x 18 —0 PLUS 5-0" OF SPECIAL PAVING W z STALL W o CLEARANCE AREA 0 (7) REGULAR STALLS W WWWWWWWWW 09'-0„x16'-0„ W W W W W W W W W. 24'-0" EXISTING Wo W W W6 ° D.IAW W W •. ENTRY DRIVEWAY 3. 3 REGULAR PARKING STALLS PROVIDED PER ATTACHED IVY TR'Er- JOINT PARKING AGREEMENT WITH NEIGHBOR. W W W W W W W W W W W y W N N N N N N N N 4 M W W W W W W W W W W W W 4 W W W W W W W -W ♦ W W W W W W W W W♦-� ♦ - PROPERTY LINE 50'-0', PROPOSED SITE PLAN TYPE IV LANDSCAPING NORTH REFER TO O SCALE: 1" = 10'-0" EQUIREMENT 7 6 TH AVENUE WEST OCCUPANT LOAD CALCULATION OCCUPANT LOAD FACTOR OCCUPANT LOAD OCCUPANT LOAD SQ. FT. PER 2018 IBC CH. 10 BY RATIO PER SF BY TOTAL GROSS ACTUAL OCCUPANT SF 426 goo cRoss 4.260000 4.000000 240 GROSS 525 35 NET 293 goo cRoss 354 300 GROSS 2.037500 15.000000 2.930000 1.180000 19.000000 2.000000 6 6 10.000000 2.000000 7.000000 12 REMARKS STAFF SERVE BOTH FLOORS ACTUAL 10 CHILD STAFF SERVE BOTH FLOORS STAFF SERVE BOTH FLOORS W U 14G32 - 14th Ave. 5E Mill Creek, WA 980 12 (425) 5 1 2- 1 760 dwude516jn@6Jm3i1.com PROJECT: Nova Family Resource and Childcare Center Conditional Use & Remodel Permit LOCATION: 21010 76th Ave. W. Edmonds, WA 98026 PERMIT PLAN SET SITE PLAN DETAILS & PARKING ANALYSIS FILE: 2023-011 DATE: 06/15/2023 PREPARED BY: D. Wu REVISIONS: 1�CITY COMMENT RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NUMBER: 39'-5" (EXISTING BUILDING, FIELD VERIFY) 39'-5" (EXISTING BUILDING, FIELD VERIFY) 50'-0" (EXISTING BUILDING, FIELD VERIFY) EXISTING/UPPER CONSTRUCTION NOTES LEGEND FLOOR PLAN FOR BOTH UPPER AND LOWER FLOORS EXISTING CONDITION TO REMAIN '(FOR REFERENCE 1. REFER TO PLUMBING AND MECHANICAL PLANS PREPARED BY SUB -CONTRACTORS. NEW CONSTRUCTION ALL BATHROOM AND LAUNDRY EXHAUSTS WILL BE 'NUTONE' BRAND 50 CFM, ONLY EXHAUST THRU ROOF TYPICAL. INTERIOR PARTITION TO BE REMOVED NO WORK EXCEPT 2, GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FUNCTIONAL TESTING OF PROVIDE SMOKE AUTOMATIC LIGHTING CONTROLS, PROVIDE OCCUPANCY SENSOR FOR ALL ROOMS. ROOM SYMBOL AND CARBON MONOXIDE ALARM & EXIT SIGN AS SHOWN SCALE: 1/4" = 1' "" 41'-3" (EXISTING BUILDING FIELD VERIFY) 3. SHADED AREA SHOWN ON PLAN IS 44 CLEAR PATHWAY FOR EMERGENCY EGRESS PER 2018 IBC SECTION 1006 & 1008. FIRE EXTINGUISHER M EMERGENCY EGRESS LIGHT SHOWN ON PLAN ALONG EGRESS PATHWAY, EXIT LIGHT DOOR SYMBOL AT EACH END OF EXIT DOORWAY WITH EMERGENCY BACK-UP POWER PROVIDED. LIGHTED EXIT SIGN: PER 2018 IBC SECTION 5. NO EXTERIOR WORK. ALL INTERIOR WALLS ARE 2x4 @ 16" o.c. WITH 1/2" GWB ON 1008.3.51 IN THE EVENT OF POWER FAILURE, BOTH SIDES UNLESS OTHERWISE NOTED. THE SYSTEM SHALL BE AUTOMATICALLY PROVIDED WITH POWER FROM AN 6. PROVIDE WATER-RESISTANT GWB BEHIND ALL PLUMBING FIXTURES, PROVIDE EMERGENCY SYSTEM. PER WSEC LIGHTING WATER-RESISTANT WAINSCOT = 48" PLASTIC LAMINATE AROUND RESTROOM. CHECKLIST C405.3 PER CODE. FIXTURES, FINISHES AND ACCESSORIES SHALL BE AS APPROVED BY TENANT. EGRESS EMERGENCY ILLUMINATION: FIXTURE SHALL BE INSTALLED AND SHALL SMOKE DETECTORS (S.D.) ARE REUIRED FOR ALL ROOMS AND HALLWAY, HAVE AT LEAST AN AVERAGE OF HARDWIRED AND INTERCONNECTED WITH BATTERY BACK-UP. 1 FOOT-CANDLE AND A MIN. AT ANY POINT OF 0.2-FOOT CANDLE MEASURED ALONG THE CARBON MONOXIDE ALARM ARE REQUIRED PER FLOOR AND SHALL COMPLY WITH PATHS OF EGRESS AT UL2034, TYPICAL. THE FLOOR LEVEL. PER WSEC LIGHTING CHECKLIST C405.2.5, AUTOMATIC SHUT OFF 0. PROVIDE 2A-10BC PORTABLE FIRE EXTINGUISHER PER PLAN AS F.E.. PER CODE. NOTES: DOOR SCHEDULE 1. ALL DOORS REQUIRED FOR ADA COMPLIANCE TO BE FITTED W/APPROVED LEVER -TYPE HARDWARE & SHALL NOT REQUIRE TIGHT GRASPING NUMBER WIDTH HEIGHT MAT./FINISH REMARKS TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE. UNLATCHING 9 SHALL NOT REQUIRE MORE THAN ONE OPERATION, 101 3'-0" 6'-8" NEW HOLLOW WOOD DOOR 2. MAX. 1/2" THRESHOLD 3. FOR EXISTING EXTERIOR A.F.F. DOORS, PROVIDE PANIC HARDWARE. 102 39 —O 99 69 -8 99 NEW HOLLOW WOOD DOOR POSTED:'EMPLOYEE USE ONLY' 103 3' —0 " 6' —g" NEW HOLLOW POSTED: 'ACCESS WOOD DOOR, TO RESTROOM NO MANUALLY OPERATED PERMITTED. FLUSH BOLT OR SURFACE BOLTS ARE NOT 104 3'-0" 6'-8" NEW HOLLOW WOOD DOOR, POSTED: 'RESTROOM' 4. ALL EXISTING EXTERIOR EXIT SIGN WITH BACK-UP EXIT DOORS SHOWN REQUIRED EMERGENCY BATTERY, TYPICAL. POSTED: 'THIS DOOR TO BUILDING, FIELD VERIFY) BE REMAINED UNLOCK WHEN OCCUPIED'. 50'-0" (EXISTING 41'-3" (EXISTING 39'-5" BUILDING (EXISTING FIELD BUILDING, VERIFY) FIELD VERIFY) .E. EX E IST\ DO D OR *SMOKE DETECTOR NEW TEACHER STORAGE/ LOUNGE) EXIT PROVIDE SELF —CLOSER FOR EMERGENCY EXIT, PROVIDE LIGHTED EXIT SIGN WITH BATTERY BACK—UP PROVIDE SELF —CLOSER EXISTING EXTERIOREXISTING EXTERIOR AND WINDOWS, WINDOWS, \ WALLS AND WINDOWS O REMAIN NO WORKTO REMAIN NO WORK, TYPICAL TYPICAL EXIST EXT. D 67RR OFFICE .,SMOKE DETECTOR (NO CHANCE) SMOKE T.E BREAKROOM DETECTOR E T. 0 (NO CHANGE) DOOR 102 x ®® LL NEW EMERGENCY KE EXIT SIGN W/BACK—UP `DETE�TOR BATTERY, TYP. 48" MIN. EGRESS EXI S . POSTED: 103 CLEAR PATHWAY DO ACCESS TO @ HALLWAY ';SMOKE DETECTOR R E S TR O O M * SMOKE DETECTOR RECEPTION AREA (NO CHANGE) NEW EMERGENCY EXIT SIGN W/ BACK—UP EXIT BATTERY, TYP. E T. NEW ING'\�,[ EXT. FDORI NTAIN D00 PROVIDE SELF —CLOSER PROVIDE SELF —CLOSER NEW STORAGE EXI T. D00 JTABLE ACCESSI 104 RESTROOM iREFER TO 50 CFM A — 6 FAN F=7 olio 0 wH CHILDCARE r5(1ILDREN, AGE RANGE 5 YEARS OLD) 04 POSTED: ACCESS TO UPPER FLOOR NEW EMERGENCY OFFICE ONLY' EXIT SIGN W/ UP BACK—UP E EXIT EXIT BATTERY, TYP. E ST. EXIST. XI EXT. DOOR T. DOOR D OR Y XISTING LECTRICAL ANEL 0 REMAIN 0 WORK 41'-3" (EXISTING BUILDING FIELD VERIFY) —I 1 OOR PLAN 14632 - 14th Ave. SE Mill Creek, WA 98012 (425) 512-1780 dwudesign@gmail.com PROJECT: Nova Family Resource and Childcare Center Conditional Use & Remodel Permit LOCATION: 21010 76th Ave. W. Edmonds, WA 98026 PERMIT PLAN SET EXISTING UPPER FLOOR PLAN, NO WORK PROJECT AREA LOWER FLOOR PLAN FILE: 2023-011 DATE: 06/15/2023 PREPARED BY: D. Wu REVISIONS: CITY COMMENT RESUB Aug 03 2023 CITY OF EDMONDS s DEPARTMENT SHEET NUMBER: A-3 EXISTING LOWER FLOOR PLAN SCALE: 1/4" = 1'-0" PROJECT AREA (INTERIOR REMODEL ONLY SCALE: 1/4" = 1'-0" PROPOSED LOWER FL SCALE: 1/4" = 1'-0" (E Bl FIEL OCCUPANT FACTOR CH CD CARE: 55 SF NET PER PERSON OFF CEo 100 SF PER PERSON GENERAL OFFICE OF � CONSULTATION: 0 240 SF PER PERSON ACCESSORY STORAGE: 500 SF CROSS PER PERSON roll ^11 le-% P91 Ill P'11A It-% rlrl P'% \ /r P'11 r\/\ FIXTURE TYPE CHILDCARE & CHILD DAY CARE PROPOSED OCC. LOAD PROPOSED FIXTURE ROOM NAVE UPPER FLOOR OFFCE UPPER FLOOR GENERA 1 OFFICE OF � CONSULTATION UP �L0 AL: LOWER FLOOR CHILDCARE LOWER FLOOR OFFICE SOWER FLOOR STORAGE LOWER FLOOR TOTAL: 41'-3" (EXISTING BUILDING FIELD VERIFY) roll ^11 /r\/IP%TIA le-% P91 Ill P'11A It-% rlrl 11 \ /r P91r\/% OCCUPANT & EGRESS EXIT FOR LOWER FLOOR PLAN NORTH )_ SCALE: 1/4" = V-0" FOR LOWER FLOOR CHLDCARE VN. PLUVBhG FA0LMES PER 2018 �BC SEC, 2902 TABLE 2902.1 REWRED - WATER CLOSET REQUIRED - LAVATOR�ES7 SHOWER DRINKING FOUNTA�N OTHER 1 PER 15 1 PER 15 1 1 PER 100 15 15 15 REQUIRED-1, PROVIDED-1 REQUIRED-1, PROVIDED-1 1 1 OCCUPANT GOAD CALCULATION OCCUPANT GOAD FACTOR OCCUPANT LOAD OCCUPANT GOAD SQ. FT. PER 2018 IBC CH. 10 BY RATIO PER SF BY TOTAL GROSS SF 426 100 GROSS 4.260000 489 240 DROSS 2.037500 6 C0 ACTUAL OCCUPANT 4.000000 2� 000000 V 1 SERVICE SINK LEGEND SMOKE DETECTOR CARBON MONOXIDE ALARM FIRE EXTINGUISHER 1 LIGHTED EXIT SIGN: PER 2018 IBC SECTION 1008.3.51 IN THE EVENT OF POWER FAILURE, THE SYSTEM SHALL BE AUTOMATICALLY PROVIDED WITH POWER FROM AN EMERGENCY SYSTEM. PER WSEC LIGHTING REMARKS CHECKLIST C405.3 PER CODE. EGRESS EMERGENCY ILLUMINATION: FIXTURE SHALL BE INSTALLED AND SHALL STATE SERVE BOTH FLOORS HAVE AT LEAST AN AVERAGE OF 1 FOOT-CANDLE AND A MIN. AT ANY POINT OF 0.2-FOOT CANDLE MEASURED ALONG THE PATHS OF EGRESS AT THE FLOOR LEVEL. PER WSEC LIGHTING CHECKLIST C405.2.5, AUTOMATIC SHUT OFF PER CODE. 525 35 NET 1 5� 000000 10, 000000 ACTUAL 10 CH1 D 293 100 DROSS 2.930000 2.000000 STAFF SERVE BOTH FLOORS 354 300 DROSS 1 180000 STAFF SERVE BOTH FLOORS 19� 000000 7� 000000 12 41'-3" (EXISTING BUILDING FIELD VERIFY) O 14632 - 14th Ave. SE Mill Creek, WA 98012 (425) 512-1780 dwudesign@gmail.com PROJECT: Nova Family Resource and Childcare Center Conditional Use & Remodel Permit LOCATION: 21010 76th Ave. W. Edmonds, WA 98026 PERMIT PLAN SET EXITING DIAGRAM MINIMUM PLUMBING & OCCUPANT LOAD CALCULATIONS FILE: 2023-011 DATE: 06/15/2023 PREPARED BY: D. Wu REVISIONS: �1 CITY COMMENT RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NUMBER: Am 4 UPPED -LUUL� (01-1-IDES) 20 FIXTURES EXISTING INSTALL OCCUPANCY SENSOR PER PLAN IN EACH ROOM EXISTING / UPPER FLOOR PLAN (FOR REFERENCE ONLY) REPLACE EXISTING LIGHT TO LED FIXTURE SCALE: 1/4" = V-0" TYPICAL NOTES: 1) EXISTING DRYWALL CEILING TO REMAIN. 2) ALL EXISTING &NEW LIGHTING FIXTURES SHALL USE LED ONLY. 3) PROVIDE OCCUPANT SENSORY LIGHT UNIT FOR EACH ROOM. SYMBOL DESCRIPTION QUANTITY RECESSED DOWN LIGHT UPPER FLOOR (OFFICE) 6" WALL WASH WHITE RIM 20 FIXTURES EXISTING (LED) LOWER FLOOR (CHILD CARE & OFFICES) 30 FIXTURES NEW LOWER FLOOR (CHILD CARE & OFFICES) 30 NEW FIXTURES INSTALL OCCUPANCY SENSOR PER PLAN IN EACH ROOM LOWER FLOOR PLAN PROVIDE ALL NEW TO LED FIXTURE SCALE: 1/4" = V-0" LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserve Project Title Nova Family Resource and Childcare Center - 2018 WSEC For Building Department Use: Date: May 08, 202 Project Address 21010 76th Avenue West Project & Applicant Edmonds, WA 98026 Information Applicant Name David Wu Applicant Phone 425-512-1780 Applicant Email dwudesign@gmail.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Education, Preschool/Daycare Building Cond. Floor Area 1,997 Office, Other New Building or Project Cond. Floor Area 1,997 General Project Types Alteration Addition Alteration Interior Lighting Floors Above Grade 2 Lighting Scope Lighting Scope g g P Compliance Method Comoliance Method 1 -General ect Description Lighting Compliance Scope Project Type Interior / Exterior Luminaire Replacement Scope Compliance Method LPA Calculation Compliance Verification g g P P yP (Interior includes both interior & parking) P P P Adjustment P and Method Alteration Interior Lighting 50% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Additional Efficiency Options Included Project Title Nova Family Resource and Childcare Center - 2018 WSEC Date May 08, 2023 Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type P yP Specific Space Type P P yP Ceiling Height (Ft) Gross Interior Area SF ( ) LPA Watts/SF ( ) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD +Display LPD) Compliance Status P Office Enclosed> 250 sf 2,066 0.66 1,364 Healthcare facility Nursery 1,997 0.92 1,837 Proposed Total LPD 3000 Totals 3,201 3,000 COMPLIES Proposed Lighting Power Density Watts or Total Watts Fixture Type Fixture ID Quantity of Wattage Limit Total Linear Watts per Linear Proposed Fixtures (#F) per Fixture Feet (LF) Foot (WpLF) (#F x WpF) or (WpF) (LF x WpLF) Individual Fixtures Recessed downlight I 1 1 20 1 60 1 1 1,200 Recessed downlight 1 2 1 30 1 60 1 1 1,800 Proposed Total LPD 3000 Project Title Nova Family Resource and Childcare Center - 2018 WSEC May 08, 2023 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (50% or more replaced)iii C Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures 14632 - 14th Ave. SE Mill Creek, WA 98012 (425) 512-1780 dwudesign@gmail.com PROJECT: Nova Family Resource and Childcare Center Conditional Use & Remodel Permit LOCATION: 21010 76th Ave. W. Edmonds, WA 98026 PERMIT PLAN SET REFLECTED CEILING PLAN & 2018 WASHINGTON STATE ENERGY CODE LIGHTING ALLOWANCE WORKSHEET FILE: 2023-011 DATE: 06/ 15/2023 PREPARED BY: D. Wu REVISIONS: RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVI ES DEPARTMENT SHEET NUMBER: I Recessed downlight I 1 I A-6 I Incandescent I I Existing I I I I Fixture Description: Can Light I Are these fixtures located within a daylight zone?: No I Do these fixtures require specific application lighting controls?: None required Recessed downlight 1 2 1 A-6 LED New Fixture Descrintion: Can Light I Are these fixtures located within a davlieht zone?: No A-5 W � U � Q O Q W Ln U JL_I N UI \ ENLARGED ACCESSIBLE RESTROOM ON LOWER FLOOR SCALE: 1" = 1'-0" RESTROOM GENERAL NOTES: 1. TOILET ROOM PLAN & ELEVATIONS ILLUSTRATE FIXTURE CLEARANCE DIMENSIONS, MOUNTING HEIGHTS AND ACCESSORY PLACEMENT. 2. LOWER EDGES OF LAVATORY TO BE 2'-3" MIN. ABOVE FINISH FLOOR FOR KNEE CLEARANCE. 3. MIRROR TO BE MOUNTED (BOTTOM EDGE OF REFLECTIVE SURFACE) S-4" MAX. ABOVE FINISH FLOOR. 4. GRAB BARS TO BE 1-1 /4" - 1-1/2" IN DIAMETER, MOUNTED 1-1/2" FROM WALL. BARS SHALL BE CAPABLE OF SUPPORTING 300LB LIVE LOAD WITHOUT PERMANENT DEFLECTION. 5. LAVATORY RIM TO BE 34" ABOVE FINISH FLOOR. 6. FLOORS SHALL BE SMOOTH, HARD, NON -ABSORBENT SURFACE SUCH AS SHEET VINYL OR OTHER AS ACCEPTABLE BY LOCAL HEALTH AND BUILDING DEPARTMENTS. FLOORING MATERIAL MUST EXTEND ONTO THE WALLS AT LEAST 6". SEE FINISH SCHEDULE FOR MORE INFORMATION. 7. DIMENSIONS, NOTES AND EQUIPMENT TYPICAL FOR ALL TOILET ROOMS, UNLESS NOTED OTHERWISE. 8. 9. TOILET ROOM FAN TO BE INTEGRALLY SWITCHED WITH TOILET LIGHT AND VENTED TO THE OUTSIDE. 10. 11. PROVIDE PAPER TOWEL DISPENSER. UNIT TO BE MOUNTED SO THAT CONTROLS OR OPENING ARE LOCATED 40" MAX. ABOVE FINISH FLOOR. 12. GYPSUM BOARD APPLIED TO PLUMBING WALLS SHOULD BE WATER-RESISTANT. 13. WATER CLOSET FLUSH VALVE TO BE ON OPEN SIDE OF TANK. 14. PROVIDE BLOCKING AS REQUIRED TO SUPPORT SINK, GRAB BARS, AND OTHER HARDWARE. 15. TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 309.4. WHERE THE DISPENSER IS LOCATED ABOVE THE GRAB BAR, THE OUTLET OF THE DISPENSER SHALL BE LOCATED WITHIN AN AREA 24 INCHES (610 MM) MINIMUM AND 36 INCHES (915 MM) MAXIMUM FROM THE REAR WALL. WHERE THE DISPENSER IS LOCATED BELOW THE GRAB BAR, THE OUTLET OF THE DISPENSER SHALL BE LOCATED WITHIN AN AREA 24 INCHES (610 MM) MINIMUM AND 42 INCHES (1065 MM) MAXIMUM FROM THE REAR WALL. THE OUTLET OF THE DISPENSER SHALL BE LOCATED 18 INCHES (455 MM) MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE FLOOR. DISPENSERS SHALL COMPLY WITH SECTION 609.3. DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY, OR DO NOT ALLOW CONTINUOUS PAPER FLOW. 16. OUTLET SHALL BE 15" MIN AND 48" MAX ABOVE FINISH FLOOR. THERE SHALL BE 1-1/2" MIN. CLEARANCE BELOW AND 12" MIN. ABOVE THE GRAB BAR. 17. OTHER DISPENSERS AND DISPOSAL FIXTURES SHALL BE LOCATED 40" MAX. ABOVE FINISH FLOOR, MEASURED TO ANY RACK, OPERATING CONTROL, RECEPTACLE OR DISPENSER. 18. WALLS WITHIN 2 FEET OF WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NON -ABSORBENT SURFACE TO A HEIGHT OF 4'-0" ABOVE FINISH FLOOR. t 0 ACCESSIBLE RESTROOM SIGNS NO SCALE _ _1 Q U z. ALL HANDICAP ROOMS TO HAVE SIGNAGE PER ICC (ICC Al 17.1 SECTION 703.6.3.1) ALL INTERIOR SIGNS DEPICTING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL COMPLY WITH SECTION 703 (ICC A117.1 SECTION 703) ALL ACCESSIBLE SIGNAGE DEPICTING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE WHITE ON A BLUE BACKGROUND PER 1101.2.6 IN THE WA STATE AMENDMENTS TO THE IBC. MOUNT ACCESSIBLE SIGNS 40" MIN A.F.F., MEASURED TO THE BASELINE OF THE CHARACTER PER ICC/ANSI 1 17.1-2009 SECTION 703.4.5 ACCESSIBLE; SYMBOLS KEY SCALE %" = V-0" 42" LO 24" LO 24" 00 L 12"X48" MANEUVERING CLEARANCE @ PUSH SIDE OF DOOR FRONT APPROACH WITH LATCH AND CLOSER 18"X60" MANEUVERING CLEARANCE @ PULL SIDE OF DOOR FRONT APPROACH 36"X60" MANEUVERING CLEARANCE @ PULL SIDE OF DOOR HINGE APPROCH 22"X48" MANEUVERING CLEARANCE @ PUSH SIDE OF DOOR FOR HINGE SIDE APPROACH WITH LATCH AND CLOSER 42"X54" MANEUVERING CLEARANCE @ PULL SIDE OF DOOR HINGE APPROACH ALTERNATE 24"X54" MANEUVERING CLEARANCE @ PULL SIDE OF DOOR LATCH APPROACH WITH CLOSER 24"X48" MANEUVERING CLEARANCE @ PUSH SIDE OF DOOR FOR LATCH SIDE APPROACH WITH CLOSER 60" F 60" L_ F 60" L 60"X56" CLEAR FLOOR SPACE @ FLOOR MOUNT TOILET (INDIVIDUAL RESTROOM) 60"X56" CLEAR FLOOR SPACE @ WALL HUNG TOILET (RESTROOM COMPARTMENTS) 60"X59" CLEAR FLOOR SPACE @ FLOOR MOUNT TOILET (RESTROOM COMPARTMENTS) 30"X48" CLEAR FLOOR SPACE @ SINK — VERTICAL APPROACH 60" TURN AROUND CIRCLE IE2��P0R E X ER �SEMI—FLUS_H__1715�1� 14G32 - 14th Ave. 5E Mill Creek, WA 98012 (425) 5 1 2- 1 760 dwude5ign@gmail.com PROJECT: Nova Family Resource and Childcare Center Conditional Use & Remodel Permit LOCATION: 21010 76th Ave. W. Edmonds, WA 98026 PERMIT PLAN SET ENLARGED RESTROOM FLOOR PLAN DETAILS FILE: 2023-011 DATE: 06/15/2023 PREPARED BY: D. Wu REVISIONS: RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NUMBER: A-6 Table 703.3.1 Braille Dimensions Measurement Range Minimum in Inches Maximum in Inches Dot base diameter 0.059 to 0.063 Distance between two dots in the some cell' 0.090 to 0.100 Distance between corresponding 0.241 dots in adjacent cells' to 0.300 Dot height 0.025 to 0.037 Distance between corresponding dots 0.395 from one cell directly below' to 0.400 1. Measured center to center. distance between corresponding dots in adiacent cells distance between dots some • • 0 in adjacent cells single braille cell _Z 0 1 0 • ; 00 00 �I 00 �I l 1 blank cell distance between corresponding dots from one cell directly — — raised dot below _ • 0 � 00 0 • • i 00 i • base diameter O 000`O, — — no raised dot Figure 703.3.1 Braille Measurement 703.3.2 Position. Braille shall be positioned below the corresponding text. If text is multi —lined, braille shall be placed below the entire text. Braille shall be separated 3/8 inch minimum from any other tactile characters and % inch minimum from raised boarders and decorative elements. 703.4 Installation Height and Location. 703.4.1 Height Above Finish Floor or Ground. Tactile characters on signs shall be located 48 inches minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. EXCEPTION: Tactile characters for elevator car controls shall not be required to comply with 703.4.1. Figure 703.4.1 Height of Tactile Characters Above Finish Floor or Ground 703.4.2 Location. Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. Where a tactile sign is provided at double doors with two active leafs, the sign shall be located to the right of the right hand door. Where there is no wall space at the latch side of a single door or at the right side of double doors, signs shall be located on the nearest adjacent wall. Signs containing tactile characters shall be located so that a clear floor space of 18 inches minimum by 18 inches minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position. EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold -open devices. MINIMUM RESTROOM PLUMBING FIXTURE REQUIREMENT, PROVIDED ONLY IF REPLACEMENT IS NECESSARY. WITHIN THIS SCOPE OF WORK, NO WORK SHOULD BE @ THE (2) ADA RESTROOM 60" MIN 31 MIN. 1 MIN._24" .MIN X Q z x Q lam' o i� 16-18" W. C. FRONT VIER N.T.S. WATER-RESISTANT WAINSCOT LINE OF WALL OR PARTITION 3/4" FIRE-RETARDENT PLYWOOD SHEATHING BEHIND GWB, THIS WALL ONLY GRAB BAR 1-1/2" DIA. 6" COVE BASE, TYP 6" MIN CLR 30" WIDE MIN. CLEAR Figure 703.4.2 Location of Tactile Signs at Doors LIGHT FIXTURE (WHERE OCCURS) MIRROR INSULATE EXPOSED SUPPLY & DRAIN LINES WITH VINYL COVERED INSULATION LAVATORY ELEVATION 39"— 41 " 54" MIN 12" MAX. z �42"M I . 00 703.5 Visual Characters. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to comply with 703.5.2 through 703.5.9. 703.5.1 Finish and Contrast. Characters and their background shall have a non —glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on a light background. Advisory 703.5.1 Finish and Contrast. Signs are more legible for persons with low vision when characters contrast as much as possible with their background. Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text and its background colors and textures. 703.5.2 Case. Characters shall be uppercase or lowercase or a combination of both. 703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms. 703.5.4 Character Proportions. Characters shall be selected form fonts where the width of the uppercase letter "0" is 55 percent minimum and 110 percent maximum of the height of the uppercase letter "I". 703.5.5 Character Height. Minimum character height shall comply with Table 703.5.5. viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign. Character height shall be based on the uppercase letter "I". Table 703.5.5 Visual Character Height Height to Finish Floor or Ground From Horizontal Viewing Distance Minimum Character Height Baseline of Character 40 inches to less than Less than 72 inches 5/8 inch or equal to 70 inches 72 inches and greater 5/8 inch, plus Y8 inch per foot of viewing distance above 72 inches 703.5.6 Height From Finish Floor or Ground. Visual characters shall be 40 inches minimum above the finish floor or ground. 703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character. 703.5.8 Character Spacing. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height. 703.5.9 Line Spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height. PTD SND SD SCD xQ CD TP a Ln z � 00 cfl i 0 I I Ln N Ln 1 2 3 4 5 CS r0 LEGEND: I I 1. PTD: PAPER TOWEL DISPENSER/WASTE RECEPTACLE 2. SND: SANITARY NAPKIN/TAMPON DISPOSAL 3. TP: TOILET PAPER HOLDER DISPENSER SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY, OR THAT DO NOT ALLOW CONTINUOUS PAPER FLOW. OPERABLE 7" MIN./9 MAX PARTS SHALL BOPERABLE REQU RE T GHTGRASP N,PINCHING, ONE OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 LBS. MAX. 4. SCD: SEAT COVER DISPENSER 5. SD: SOAP DISPENSER, WALL MOUNTED W.C. SIDE VIEW- N. T. S. ELEVAT ON S N.T.S. 25" MAX. 703.6 Pictograms. Pictograms shall comply with 703.6. 703.6.1 Pictogram Field. Pictograms shall have a field height of 6 inches minimum. Characters and braille shall not be located in the pictogram field. C E M EN not in pictogram field • Figure 703.6.1 Pictogram Field 703.6.2 Finish and Contrast. Pictograms and their field shall have a non —glare finish. Pictograms shall contrast with their field with either a light pictogram on a dark field or a dark pictogram on a light field. Advisory 703.6.2 Finish and Contrast. Signs are more legible for persons with low vision when characters contrast as much as possible with their background. Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text and background colors and textures. 703.6.3 Text Descriptors. Pictograms shall have text descriptors located directly below the pictogram field. Text descriptors shall comply with 703.2, 703.3 and 703.4. 703.7 Symbols of Accessibility. 703.7.1 Finish and Contrast. Symbols of accessibility and their background shall have a non —glare finish. Symbols of accessibility shall contrast with their background with either a light symbol on a dark background of a dark symbol on a light background. Advisory 703.7.1 Finish and Contrast. Signs are more legible for persons with low vision when characters contrast as much as possible with their background. Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text and background colors and textures. 2x6 BLOCKING @ MIRROR 2x12 BLOCKING @ VANITY LAVATORY RIM x P. LAM. COUNTER OVER 3/4" MDO PLYWOOD N o _ � Ln Q0 0 8 MFTAI I —RRAC KFTS 2"x2" FALL SIDE OF PLYWOOD OUTRIGGERS (TYPICAL) 3/4" PLAOOD OUTRIGGERS LOCATE PEAR PLAN, PAINT TO L'-J MATCH P-LAM VANITY TOP 3/4" PLYWOOD FRAME @ cn CONTINUOgS FRONT. FRONT & W BACK SIDEI AS SHOWN W z INSULATE PIPES: REFER WALL PER PLAN TO NOTE BELOW z_ L1 _I z Q 11 MIN 48" MIN CLEAR FLOOR SPACEcf) 0 17" MIN TOE SPACE NOTE: WATER SUPPLY AND DRAIN PIPES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OF ABRASIVE SURFACES UNDER LAVATORIES AND SINKS. LAVATORY SINK COUNTERS 14G32 - 14th Ave. 5E Mill Creek, WA 98012 (425) 5 1 2- 1 760 dwude5ign@gmail.com PROJECT: Nova Family Resource and Childcare Center Conditional Use & Remodel Permit LOCATION: 21010 76th Ave. W. Edmonds, WA 98026 PERMIT PLAN SET ARCH DETAILS FILE: 2023-011 DATE: 06/15/2023 PREPARED BY: D. Wu REVISIONS: RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NUMBER: A-7 N.T.S. N.T.S. 4x CONT.- TOP PLATE WITH 3/4" DIA. ANCHOR BOLTS EXISTING BUILDING CEILING JOIST, TYP. 6"x3-1/2"x4" LONG x7 GA BENT PLATE ON BOTH SIDE OF TOP PLATE WITH 2-1/4" DIA.x3" LAG SCREWS. 2x6 H F# 2 @ 16" 1/2" G.W.B. ON BOTH SIDES, O.C. TYP. HORIZONTAL BRIDGING @ %2 POINT 6" COVED BASE 2X6 BASE PLATE FASTEN TO FLOOR PROVIDE BLOCKING IN WALLS AS REQUIRED FOR: A. DOOR FRAMES B. WALL MOUNTED DOOR STOPS C. OTHER ITEMS AS NECESSARY LVIIIIIIIIIINEMBUNIIIIIIIIII EAD OF ROOF EMENT OOFING CUT TO T OVER PIPE UNDERLAYMENT STEP 1 VENT PIPE PREFORMED FLANGE PLACE OVER PIPE AND SET IN ASPHALT PLASTIC CEMENT UNDERLAYMENT BEAD OF SEALANT PIPE AND STEP 2 URETHANE BETWEEN FLANGE APPLICATION OF ROOFING AROUND PIPE FLASHING TYPICAL ALL BATHROOMS EXHAUST VENTS THROUGH EXISTING ROOF USE DETAIL AS NEEDED STEP 3 "M�ER AND SIDE )FIND OVERLAP NGE IER PART OF NGE OVERLAPS IER ROOFING 14632 - 14th Ave. 5E Mill Creek, WA 98012 (425) 5 1 2- 1 760 dwudesign@gmail.com PROJECT: Nova Family Resource and Childcare Center Conditional Use & Remodel Permit LOCATION: 21010 76th Ave. W. Edmonds, WA 98026 PERMIT PLAN SET ARCH DETAILS FILE: 2023-011 DATE: 06/15/2023 PREPARED BY: D. Wu REVISIONS: RESUB Aug 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET NUMBER: N.T.S. A-s