REVIEWED-RESUB1 BLD2022-0866+Structural_Calculations+9.26.2022_12.10.04_AM+3127663WILSON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
CS2018 Ver 2021.03.22
RESUB
Sep 26 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
............................................
REVIEWED
BY
CITY OF EDMONDS
BUILDING DEPARTMENT
bId2022-0866
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 980
JOB NO.
CALCULATED BY HAJ
CHECKED BY HAJ
W 8j HAJ
Wilson & HAJ Consultant Engineers, LLC
STRUCTURAL CALCULATIONS
FOR
WOLLA RESIDENCE REMODEL
C
SHEET NO.
DATE 1/19/22
DATE
;ON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 9802
JOB NO. SHEET NO.
CALCULATED BY HAJ DATE 1/19/22
CHECKED BY HAJ DATE
www.struware.com
Code Search
Code: International Building Code 2018
Occupancy:
Occupancy Group = R Residential
Risk Category & Importance Factors:
Risk Category = II
Wind factor = 1.00
Snow factor = 1.00
Seismic factor = 1.00
Type of Construction:
Fire Rating:
Roof = 1.0 hr
Floor = 1.0 hr
Building Geometry:
Roof angle (0)
3.00 / 12 14.0 deg
Building length
33.0 ft
Least width
25.0 ft
Mean Roof Ht (h)
13.0 ft
Parapet ht above grd
0.0 ft
Minimum parapet ht
0.0 ft
Live Loads:
Roof 0 to 200 sf: 20 psf
200 to 600 sf: 24 - 0.02Area, but not less than 12 psf
over 600 sf: 12 psf
Floor:
Typical Floor
40 psf
Partitions
15 psf
Lobbies & first floor corridors
100 psf
Corridors above first floor
80 psf
Balconies (1.5 times live load)
60 psf
SON & HAJ CONSULTANT ENGINEERS, LLC
JOB TITLE WOLLA RESIDENCE REMODEL
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
Wind Loads:
Ultimate Wind Speed
Nominal Wind Speed
Risk Category
Exposure Category
Enclosure Classif.
Internal pressure
Directionality (Kd)
Kh case 1
Kh case 2
Type of roof
ASCE 7- 16
110 mph
85.2 mph
11
C
Enclosed Building
+/-0.18
0.85
0.849
0.849
Gable
23508 94TH. AVE. WEST EDMONDS 98
JOB NO.
CALCULATED BY HAJ
CHECKED BY HAJ
SHEET NO.
DATE 1/19/22
DATE
SON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO.
CALCULATED BY HAJ
CHECKED BY HAJ
Wind Loads - MWFRS h:56W (Low-rise Buildings) except for open buildings
Kz = Kh (case 1) = 0.85
Base pressure (qh) = 22.4 psf
GCpi = +/-0.18
Wind Pressure Coefficients
SHEET NO.
DATE 1/19122
DATE
Edge Strip (a) = 3.0 ft
End Zone (2a) = 6.0 ft
Zone 2 length = 12.5 ft
CASE A
CASE B
B=14deg
Surface
GC f
w/-GC i
w/+GC i
GC f
w/-GC i
w/+GC i
1
0.48
0.66
0.30
-0.45
-0.27
-0.63
2
-0.69
-0.51
-0.87
-0.69
-0.51
-0.87
3
-0.44
-0.26
-0.62
-0.37
-0.19
-0.55
4
-0.37
-0.19
-0.55
-0.45
-0.27
-0.63
5
0.40
0.58
0.22
6
-0.29
-0.11
-0.47
1 E
0.72
0.90
0.54
-0.48
-0.30
-0.66
2E
-1.07
-0.89
-1.25
-1.07
-0.89
-1.25
3E
-0.63
-0.45
-0.81
-0.53
-0.35
-0.71
4E
-0.56
-0.38
-0.74
-0.48
-0.30
-0.66
5E
0.61
0.79
0.43
6E
-0.43
-0.25
-0.61
Ultimate Wind Surface Pressures (psf)
1
14.7 6.7
-6.0 -14.1
2
-11.4 -19.4
-11.4 -19.4
3
-5.7 -13.8
-4.2 -12.3
4
-4.3 -12.4
-6.0 -14.1
5
13.0 4.9
6
-2.5 -10.5
1 E
20.2 12.2
-6.7 -14.8
2E
-19.9 -27.9
-19.9 -27.9
3E
-10.0 -18.0
-7.8 -15.9
4E
-8.4 -16.5
-6.7 -14.8
5E
17.7 9.6
6E
-5.6 -13.6
Parapet
Windward parapet = 0.0 psf (GCpn = +1.5)
Leeward parapet = 0.0 psf (GCpn = -1.0)
Horizontal MWFRS SImDle Diaphragm Pressures (Dsf
Transverse direction (normal to L)
Interior Zone: Wall
19.1 psf
Roof
-5.7 psf
End Zone: Wall
28.6 psf
Roof
-9.9 psf "
Longitudinal direction (parallel to L)
Interior Zone: Wall 15.4 psf
End Zone: Wall 23.2 psf
*" NOTE: Total horiz force shall not be less than that determined
by neglecting roof forces (except for MWFRS moment frames).
The code requires the MWFRS be designed for a min ultimate
force of 16 psf multiplied by the wall area plus an 8 psf force
applied to the vertical projection of the roof.
Windward roof
overhangs = 15.6 psf (upward) add to
windward roof pressure
WINDWARD
OVERHANG WINDWARDROOF
LEEWARD ROOF
! l l 1 L! L I I l S
VERTICAL
� z
B!2 or ZONE 2
TRANSVERSE ELEVATION
WINDWARD ROOF
! LEEWARD ROOF
!! 1 1 1 1 1 1
VERTICAL
z LI2 or ZONE 2
� a
z
LONGITUDINAL ELEVATION
SON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO. SHEET NO.
CALCULATED BY HAJ DATE 1/19/22
CHECKED By HAJ DATE
Wind Loads - h:560' Longitudinal Direction MWFRS On Open or Partial
Enclosed Buildings with Transverse Frames and Pitched Roofs
Base pressure (qh) = 22.4 psf
GCpf = +/-0.18 Enclosed bldg, procdure doesn't apply
Roof Angle (6) = 14.0 deg
ASCE 7-16 procedure
B= 25.0 ft
# of frames (n) =
5
Solid are of end wall including fascia (As) =
1,500.0 sf
Roof ridge height =
14.6 ft
Roof eave height =
11.4 ft
Total end wall area if soild (Ae) =
325.0 sf
Longidinal Directional Force (F) = pAe
p= qh [(GCpf)windward-(GCpf)leeward] KB Ks
Solidarity ratio (0) =
4.615
n=
5
KB =
1.55
KS =
20.356
Zones 5 & 6 area =
288 sf
5E & 6E area =
37 sf
(GCpf) windward - (GCpf) leeward] =
0.729
p =
514.4 psf
Total force to be resisted by MWFRS (F) = 167.2 kips applied at the centroid
of the end wall area Ae
Note: The longidudinal force acts in combination with roof loads
calculated elsewhere for an open or partially enclosed building.
SON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
ZONE 2: lessor of
If 2 is negative
CASE A �'iNDDMECTION
RANGE
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO. SHEET NO.
CALCULATED BY HAJ DATE 1/19/22
CHECKED By HAJ DATE
CASE B
RYZND DIRECTTON
RANCH.
NOTE: Torsional loads are 25% of zones 1 - 6. See code for loading diagram.
Exception: One story buildings h<30' and 1 to 2 storybuildings framed with light -frame
construction or with flexible diaphragms need not be designed for the torsional load case.
ASCE 7-98 & ASCE 7-10 (& later) - MWFRS wind pressure zones
4
3 E\
5
ZONE 2: lessor of
{ 0.5Bor2.5L
•' If 2 isnegati,
R4 M EF.CIIOIN
Transverse Direction LL ou�itudinal Direction Direction
NOTE: Torsional loads are 25% of zones 1 - 4. See code for loading diagram.
Exception: One story buildings h<30' and 1 to 2 storybuildings framed with light -frame
construction or with flexible diaphragms need not be designed for the torsional load case.
ASCE 7-02 and ASCE 7-05 - MWFRS wind pressure zones
JOB TITLE WOLLA RESIDENCE REMODEL
JILSON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
Wind Loads - Components & Claddina : h <_ 60'
Kh (case 2) = 0.85
In = 13.0 ft
Base pressure (qh) = 22.4 psf
a = 3.0 ft
Minimum parapet ht = 0.0 ft
GCpi = +/-0.18
Roof Angle (8) = 14.0 deg
qi = qh = 22.4 psf
Type of roof = Gable
Roof
Area
Negative Zone 1 & 2E
Negative Zone 2n, 2r &3e
Negative Zone 31
Positive All Zone=.
Overhang Zone 1 & 2e
Overhang Zone 2n & 21
Overhang Zone 3e
Overhang Zone 31
Parapet
qp = 0.0 psf
C
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO. SHEET NO.
CALCULATED BY HAJ DATE 1/19/22
CHECKED BY HAJ DATE
Ultimate Wind Pressures
Surface Pressure (psf)
2 sf
10 sf
20 sf
50 sf
75 sf
100 sf
200 sf
250 sf
-48.7
-48.7
-48.7
-29.6
-21.2
-16.0
-16.0
-16.0
-71.1
-71.1
-61.4
-48.7
-43.1
-39.1
-29.5
-26.4
-84.5
-84.5
-72.4
-56.4
-49.3
-44.3
-44.3
-44.3
19.7
16
16
16
16.0
16.0
16.0
16.0
-55.9
-55.9
-55.9
-43.2
-37.5
-33.5
-33.5
-33.5
-78.2
-78.2
-71
-61.5
-57.2
-54.2
-47.0
-44.7
-91.6
-91.6
-79.1
-62.6
-55.3
-50.1
-37.6
-33.5
-105
-105
-88.9
-67.6
-58.1
-51.4
-51.4
-51.4
uvernang pressures in me raDie aoove assume an inrernai pressure coerricienr tucpi/ or U.0
Overhang soffit pressure equals adj wall pressure (which includes internal pressure of 4 psf)
Surface Pressure (psf)
10 sf
20 sf
50 sf
100 sf
250 sf
500 sf
Solid Parapet Pressure
ASE A: Zone 2e :
0.0
0.0
0.0
0.0
0.0
0.0
Zone 2n, 2r & 3e :
0.0
0.0
0.0
0.0
0.0
0.0
Zone 3r:
0.0
0.0
0.0
0.0
0.0
0.0
ASE B : Interior zone :
0.0
0.0
0.0
0.0
0.0
0.0
Corner zone :
0.0
0.0
0.0
0.0
0.0
0.0
Userinput
25 sf
50 sf
-44.1
-29.6
-58.4
-48.7
-68.5
-56.4
16.0
16.0
-52.8
-43.2
-68.7
-61.5
-75.1
-62.6
-83.7
-67.6
Userinput
50 sf
0.0
0.0
0.0
0.0
0.0
Walls GCp +/- GCpi Surface Pressure at In Userinput
Area 10 sf 100 sf 200 sf 500 sf 10 sf 100 sf 200 sf 500 sf 10 sf 200 sf
Negative Zone 4 -1.28 -1.10 -1.05 -0.98 28.6 24.7 23.5 21.9 -28.6 -23.5
Negative Zone 5 -1.58 -1.23 -1.12 -0.98 -35.3 -27.4 -25.0 -21.9 -35.3 25.0
Positive Zone 4 & 5 1.18 1.00 0.95 0.88 26.4 22.4 21.2 19.7 26.4 21.2
JOB TITLE WOLLA RESIDENCE REMODEL
1ILSON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
Roofs w/ 0 <_ 10*
and all walls
h>60'
a
�
I
— I
I
I
�I I
I
—I
I
I
I
� I
f
I
�
( I
I
F---(
--
Monoslope roofs
10°<0<_30'
h 5 60' & alt design h<90'
1
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO. SHEET NO.
CALCULATED BY HAJ DATE 1/19/0
CHECKED BY HAJ DATE
Location of C&C Wind Pressure Zones - ASCE 7-10 & earlier
a
I I I 18
I ( IZi 1 r-
I
i
I
I I I
I
L
Walls h <_ 60' Gable, Sawtooth and
& alt design h<90' Multispan Gable 0 <_ 7 degrees &
Monoslope <_ 3 degrees
h 5 60' & alt design h<90'
T— —7
2
1 2 w 2 I
D 2 I 2)( I
2 t I
I I I I J � I
2
2
3} 2 3 3 2
Multispan Gable & Hip 70 < 0 < 270
Gable 7° < 0 <_ 45'
Stepped roofs 0 <_ 3°
h <_ 60' & alt design h<90'
Monoslope roofs
3°<0<10'
h 5 60' & alt design h<90'
A B C D
Sawtooth 10* < 0 < 45°
h <_ 60' & alt design h<90'
JOB TITLE WOLLA RESIDENCE REMODEL
JILSON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
Roofs w/ 0 <_ 10'
and all walls
h>60'
Monoslope roofs
10°<0<_30°
h <_ 60' & alt design h<90'
a
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO. SHEET NO.
CALCULATED BY HAJ DATE 1/19/0
CHECKED BY HAJ DATE
Location of C&C Wind Pressure Zones - ASCE 7-16
Walls h <_ 60'
& alt design h<90'
Multispan Gable &
Gable 7° < 0 <_ 45°
Stepped roofs 0 <_ 3°
h <_ 60' & alt design h<90'
r,
0. h 0.
h
a
I I
I I I
L - -
- -
- - i
Gable, Sawtooth and
Multispan Gable 0 <_ 7 degrees &
Monoslope <_ 3 degrees
h <_ 60' & alt design h<90'
a
Hip 7° < 0 < 27'
a
2a
2a
01
I
I
irfl
D
I
--J
I
I
I
I
Q
Monoslope roofs
3°<0<_10'
h <_ 60' & alt design h<90'
Sawtooth 10' < 0 <_ 45'
h <_ 60' & alt design h<90'
WILSON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
Snow Loads: ASCE 7- 16
Roof slope =
14.0 deg
Horiz. eave to ridge dist (W) =
12.5 ft
Roof length parallel to ridge (L) =
33.0 ft
Type of Roof
Hip and gable w/ trussed systems
Ground Snow Load Pg =
30.1 psf
Risk Category =
II
Importance Factor I =
1.0
Thermal Factor Ct =
1.20
Exposure Factor Ce =
1.2
Pf = 0.7*Ce*Ct*I*Pg =
30.3 psf
Unobstructed Slippery Surface
no
Sloped -roof Factor Cs =
1.00
Balanced Snow Load =
30.3 psf
Rain on Snow Surcharge Angle
0.25 deg
Code Maximum Rain Surcharge
5.0 psf
Rain on Snow Surcharge =
0.0 psf
Ps plus rain surcharge =
30.3 psf
Minimum Snow Load Pm =
20.0 psf
Uniform Roof Design Snow Load = 30.3 psf
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO.
CALCULATED By HAJ
CHECKED By HAJ
SHEET NO.
DATE 1/19/22
DATE
Nominal Snow Forces
Near ground level surface balanced snow load = 30.1 psf
NOTE: Alternate spans of continuous beams
shall be loaded with half the design roof snow
load so as to produce the greatest possible
effect - see code for loading diagrams and
exceptions for gable roofs..
ILSON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
Seismic Loads: IBC 2018
Risk Category : 11
Importance Factor (1) : 1.00
Site Class : D - code default
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO. SHEET NO.
CALCULATED BY HAJ DATE 1/19/22
CHECKED BY HAJ DATE
Strength Level Forces
Ss (0.2 sec) = 127.90 %g
S1 (1.0 sec) = 44.90 %g
A site specific ground motion analysis is required for seismically isolated structures or with damping systems, see ASCE7 11.4.8
Fa = 1.200 Sms = 1.535 SDs = 1.023 Design Category = D
Fv = 1.851 Sm1 = 0.831 Sol = 0.554 Design Category = D
Seismic Design Category = D
Redundancy Coefficient p = 1.00 Code exception must be met for p to equal 1.0
Number of Stories: 1
Structure Type: Light Frame
Horizontal Struct Irregularities: No plan Irregularity
Vertical Structural Irregularities: No vertical Irregularity
Flexible Diaphragms: Yes
Building System: Bearing Wall Systems
Seismic resisting system: Light frame (wood) walls with structural wood shear panels
System Structural Height Limit: 65 ft
Actual Structural Height (hn) = 13.0 ft
See ASCE7 Section 12.2.5 for exceptions and other system limitations
DESIGN COEFFICIENTS AND FACTORS
Response Modification Coefficient (R) = 6.5
Over -Strength Factor (0o) = 2.5
Deflection Amplification Factor (Cd) = 4
SDs = 1.000 (Sds modified for Cs & Ev calculation since
Sol = 0.554 meets ASCE 7 section 12.8.1.3)
Seismic Load Effect (E) = Eh +/-Ev = p QE +/- 0.2SDs D = Qe +/- 0.200D
Special Seismic Load Effect (Em) = Emh +/- Ev = 00 QE +/- 0.2SDs D = 2.5Qe +/- 0.205D
PERMITTED ANALYTICAL PROCEDURES
QE = horizontal seismic force
D = dead load
Simplified Analysis - Use Equivalent Lateral Force Analysis
Equivalent Lateral -Force Analysis Permitted
Building period coef. (CT) = 0.020 Cu = 1.40
Approx fundamental period (Ta) = CThn" = 0.137 sec x= 0.75 Tmax = CuTa = 0.192
User calculated fundamental period (T) = sec Use T = 0.137
Long Period Transition Period (TL) = ASCE7 map = 6
Seismic response coef. (Cs) = Sdsl/R = 0.154 ASCE7 11.4.8 exception 2 equations used
but not less than Cs = 0.044Sdsl = 0.044
USE Cs = 0.154
Design Base Shear V = 0.154W
Model & Seismic Response Analysis - Permitted (see code for procedure)
ALLOWABLE STORY DRIFT
Structure Type: All other structures
Allowable story drift Da = 0.020hsx where hsx is the story height below level x
SON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO.
CALCULATED BY HAJ
CHECKED BY HAJ
Roof Design Loads
SHEET NO.
DATE 1/19/22
DATE
Items
Description Multiple
I psf (max)
psf (min)
Roofing
Asphalt Shingles w/roll roofing
3.0
2.0
Decking
1/2" plywood/OSB
1.8
1.5
Framing
Wood Trusses @ 24"
3.0
2.5
Insulation
R-40 Fiberglass insul. x 1.0
1.3
1.2
Ceiling
Suspended acoustical tile
1.8
1.0
Mech & Elec
Mech. & Elec.
2.0
0.0
Misc.
Misc.
0.5
0.0
0.0
0.0
Actual Dead Load
0 13.4
0 8.2
Use this DL instead
• 15.0
O 15.0
Live Load
20.0
0.0
Snow Load
30.3
0.0
Ultimate Wind zone 2 - 100sf
16.0
-39.1
ASD Loading D + S
45.3
-
D + 0.75(0.6*W + S)
45.0
-
0.6*D + 0.6*W
-
-14.5
LRFD Loading 1.2D + 1.6 S + 0.5W
74.5
-
1.2D + 1.OW + 0.5S
49.2
-
0.9D + 1.0W
SON & HAJ CONSULTANT ENGINEERS, LLC JOB TITLE WOLLA RESIDENCE REMODEL
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO.
CALCULATED BY HAJ
CHECKED BY HAJ
Floor Design Loads
SHEET NO.
DATE
DATE
1 / 19/22
Items
Description Multiple
psf (max)
psf (min)
Flooring
Carpet & pad
1.0
1.0
Decking
1/2" plywood/OSB x 1.0
1.8
1.5
Framing
Wood 2x @24"
2.5
1.5
Insulation
R-30 Fiberglass insul.
0.9
0.9
None
0.0
0.0
Ceiling
Suspended acoustical tile
1.8
1.0
Sprinklers
Sprinklers
2.0
0.0
Mech & Elec
Mech. & Elec.
2.0
0.0
Misc.
Misc.
0.5
0.0
Actual Dead Load
12.5
0 5.9
Use this DL instead
15.0
O 15.0
15.0
0.0
Partitions
Live Load
40.0
.............................................
0.0
Total Live Load
55.0
0.0
70.0
15.0
Total Load
SON & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO.
CALCULATED BY HAJ
CHECKED BY HAJ
Wall Design Load #1
SHEET NO.
DATE 1/19/22
DATE
Items
Description Multiple
psf (max)
psf (min)
Sheathing
7/16" plywood/OSB
1.6
1.4
Sheathing
5/8" gypsum
2.8
2.5
Framing
2x6 wood stud @ 16"
2.0
1.1
0.0
0.0
Wall Covering
1" Wood Paneling x 0.38
0.9
0.9
Insulation
R-11 Fiberglass insul.
0.4
0.4
Mech & Elec
Mech. & Elec.
1.0
0.0
Misc.
Misc.
0.5
0.0
Actual Dead Load
O 9.2
Use this DL instead
I O 15.0
N & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
CODE SUMMARY
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO.
CALCULATED BY HAJ
CHECKED BY HAJ
Code: International Building Code 2018
Live Loads:
Roof 0 to 200 sf:
20 psf
200 to 600 sf:
24 - 0.02Area, but not less than 12 psf
over 600 sf:
12 psf
Typical Floor
40 psf
Partitions
15 psf
Lobbies & first floor corridors
100 psf
Corridors above first floor
80 psf
Balconies (1.5 times live load)
60 psf
Dead Loads:
Floor
15.0 psf
Roof
15.0 psf
Wind Design Data:
Ultimate Design Wind Speed
110 mph
Nominal Design Wind Speed
85.21 mph
Risk Category
II
Mean Roof Ht (h)
13.0 ft
Exposure Category
C
Enclosure Classif.
Enclosed Building
Internal pressure Coef.
+/-0.18
Directionality (Kd)
0.85
Roof Snow Loads.
Design Uniform Roof Snow load
= 30.3 psf
Flat Roof Snow Load
Pf = 30.3 psf
Balanced Snow Load
Ps = 30.3 psf
Ground Snow Load
Pg = 30.1 psf
Importance Factor
I = 1.00
Snow Exposure Factor
Ce = 1.20
Thermal Factor
Ct = 1.20
Sloped -roof Factor
Cs = 1.00
Drift Surcharge load
Pd =
Width of Snow Drift
w =
Earthauake Desian Data:
Risk Category
SHEET NO.
DATE 1 /19/22
DATE
www.struware.com
Importance Factor
I
= 1.00
Mapped spectral response accelerat
Ss
= 127.90
S1
= 44.90
Site Class
= ;ode default
Spectral Response Coef.
Sds
= 1.000
Sd1
= 0.554
Seismic Design Category
= D
Basic Structural System
= Bearing Wall Systems
Seismic Resisting System
= Light frame (wood) walls with structural wood shear panels
Design Base Shear
V
= 0.154W
Seismic Response Coef.
Cs
= 0.154
Response Modification Factor
R
= 6.5
Analysis Procedure
= Equivalent Lateral -Force Analysis
N & HAJ CONSULTANT ENGINEERS, LLC
909 S. 336TH. ST. #104
FEDERAL WAY, WA
206 979 3819
JOB TITLE WOLLA RESIDENCE REMODEL
23508 94TH. AVE. WEST EDMONDS 98020
JOB NO.
CALCULATED BY HAJ
CHECKED BY HAJ
CODE SUMMARY- continued
Component and cladding ultimate wind pressures
Roof
Area
Negative Zone 1 & 2e
Negative Zone 2n, 2r &3e
Negative Zone 3r
Positive All Zones
Overhang Zone 1 & 2e
Overhang Zone 2n & 2r
Overhang Zone 3e
Overhang Zone 3r
SHEET NO.
DATE 1 /1 9/22
DATE
www.struware.com
Surface Pressure (psf)
2 sf
10 sf
20 sf
50 sf
75 sf
100 sf
200 sf
250 sf
-48.7
-48.7
-48.7
-29.6
-21.2
-16.0
-16.0
-16.0
-71.1
-71.1
-61.4
-48.7
-43.1
-39.1
-29.5
-26.4
-84.5
-84.5
-72.4
-56.4
-49.3
-44.3
-44.3
-44.3
19.7
16.0
16.0
16.0
16.0
16.0
16.0
16.0
-55.9
-55.9
-55.9
-43.2
-37.5
-33.5
-33.5
-33.5
-78.2
-78.2
-71.0
-61.5
-57.2
-54.2
-47.0
-44.7
-91.6
-91.6
-79.1
-62.6
-55.3
-50.1
-37.6
-33.5
-105.0
-105.0
-88.9
-67.6
-58.1
-51.4
-51.4
-51.4
Overhang soffit pressure equals adj wall pressure (which includes internal pressure of 4 psf)
Parapet
Area
CASE A: Zone 2e
Zone 2n, 2r & 3e
Zone 3r:
CASE B : Interior zone
Corner zone
Solid Parapet Pressure (psf)
10 sf
20 sf
50 sf
100 sf
250 sf
500 sf
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
Wall
Surface Pressure (psf)
Area
10 sf 1
100 sf 1 200 sf 1
500 sf
Negative Zone 4
-28.6
-24.7 -23.5
-21.9
Negative Zone 5
-35.3
-27.4 -25.0
-21.9
Positive Zone 4 & 5
26.4
22.4 21.2
19.7
Project Title:
Engineer:
Project ID:
Project Descr:
ASCE 7-16 Seismic Base Shear
Project File: DEBI WOLLA ENECALC.ec6
LIC# : KW-06014809, Build:20.22.5.16 Wilson & HAJ Consultant Engineers, LLC (c) ENERCALC INC 1983-2022
DESCRIPTION: Seismic Base Shear Analysis
Specific Description:
Risk Category
Calculations per ASCE 7-16
Risk Category of Building or Other Structure : "II" : All Buildings and other structures except those listed as Category SCE 7-16, Page 4, Table 1.5-1
I, III, and IV
Seismic Importance Factor = 1
ASCE 7-16, Page 5, Table 1.5-2
USER DEFINED Ground Motion
ASCE 7-16 11.4.2
Max. Ground Motions, 5% Damping
Ss = 1.279 g, 0.2 sec response
S 1 = 0.4490 g, 1.0 sec response
For the closest datapoint grid location ...
Latitude = 47.810 deg North
Longitude = 122.370 deg West
Site Class, Site Coeff. and Design Category
Classification: "D" : Shear Wave Velocity 600 to 1,200 ft/sec
= D (By Default per 11.4.3) ASCE 7-16 Table 20.3-1
Site Coefficients Fa & Fv Fa =
1.20 ASCE 7-16 Table 11.4-1 & 11.4-2
(using straight-line interpolation from table val Fv =
1.85
Maximum Considered Earthquake Accelerat SMs = FaSs =
1.535 ASCE 7-16 Eq. 11.4-1
SM1 = Fv * S1 =
0.831 ASCE 7-16 Eq. 11.4-2
Design Spectral Acceleration
SIDS- SMS * 2/3 = 1.023
ASCE 7-16 Eq. 11.4-3
S D1 = SIV II * 2/3 = 0.554
ASCE 7-16 Eq. 11.4-4
Seismic Design Category
= D
ISCE 7-16 Table 11.6-1 & -2
Resisting System
ASCE 7-16 Table 12.2-1
Basic Seismic Force Resisting System ...
Bearing Wall Systems
15.Light-frame (wood) walls sheathed w/wood structural panels rated for shear resistance.
Response Modification Coefficient " I =
6.50 Building height Limits :
System Overstrength Factor " Wo " =
3.00 Category "A & B" Limit:
No Limit
Deflection Amplification Factor " Cd ' =
4.00 Category "C" Limit:
"D"
No Limit
Category Limit:
Limit = 65
NOTE! See ASCE 7-16 for all applicable
footn< Category "E" Limit:
Limit = 65
Category "F" Limit:
Limit = 65
Lateral Force Procedure
ASCE 7-16 Section 12.8.2
Equivalent Lateral Force Procedure
The "Equivalent Lateral Force Procedure" is being used according to the provisions of ASCE 7-16 12.8
Determine Building Period Use ASCE 12.8-7
Structure Type for Building Period CalculEAII Other Structural Systems
" Ct " value = 0.020 " hn " : Height from base to highest leve 13.0 ft
" x " value = 0.75
" Ta " Approximate fundemental period using Eq. 12.8-7 : Ta = Ct * (hn A x) = 0.137 sec
"TL" : Long -period transition period per ASCE 7-16 Maps 22-14 -> 22-17 6.000 sec
Building Period " Ta " Calculated from Approximate Method sel(= 0.137
" Cs " Response Coefficient ASCE 7-16 Section 12.8.1.1
SIDS: Short Period Design Spectral Response = 1.023 From Eq. 12.8-2, Preliminary Cs = 0.157
" R " : Response Modification Factor = 6.50 From Eq. 12.8-3 & 12.8-4 , Cs need not excee = 0.623
" I " : Seismic Importance Factor = 1 From Eq. 12.8-5 & 12.8-6, Cs not be less than = 0.045
Cs : Seismic Response Coefficient = = 0.1574
Project Title:
Engineer:
Project ID:
Project Descr:
ASCE 7-16 Seismic Base Shear Project File: DEBI WOLLA ENECALC.ec6
LIC# : KW-06014809, Build:20.22.5.16 Wilson & HAJ Consultant Engineers, LLC (c) ENERCALC INC 1983-2022
DESCRIPTION: Seismic Base Shear Analysis
Seismic Base Shear ASCE 7-16 Section 12.8.1
Cs = 0.1574 from 12.8.1.1 W ( see Sum Wi below) = 7.00 k
Seismic Base Shear V = Cs' W = 1.10 k
Vertical Distribution of Seismic Forces ASCE 7-16 Section 12.8.3
" k " : hx exponent based on Ta =
Table of building Weights by Floor Level...
Level # Wi: Weight Hi : Height (Wi ` Hi^k) Cvx Fx=Cvx' V Sum Story Shear Sum Story Moment
1 7.00 8.00 56.00 1.0000 1.10 1.10 0.00
Sum Wi = 7.00 k Sum Wi' Hi = 56.00 k-ft Total Base Shear = 1.10 k
Base Moment = 8.8 k-ft
Diaphragm Forces : Seismic Design Category "B" to 7" ASCE 7-16 12.10.1.1
Level # Wi Fi Sum Fi Sum Wi Fpx : Calcd Fpx : Min Fpx : Max Fpx Dsgn. Force
1 7.00 1.10 1.10 7.00 1.10 1.43 2.86 1.43 1.43
Wpx .................... Weight at level of diaphragm and other structure elements attached to it.
Fi ...................... Design Lateral Force applied at the level.
Sum Fi .................. Sum of "Lat. Force" of current level plus all levels above
MIN Req'd Force @ Level ... 0.20 * S DS I * Wpx
MAX Req'd Force @ Level .. 0.40 * S DS * I * Wpx
Fpx : Design Force @ Level . WpxSUM(x->n) Fi / SUM(x->n) wi, x = Current level, n = Top Level
Project Title:
Engineer:
Project ID:
Project Descr:
Wood Bean? Project File: DEBI WOLLA ENECALC.ec6
DESCRIPTION: J28
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Fb +
850.0 psi
E : Modulus of Elasticity
Load Combination ASCE 7-16
Fb -
850.0 psi
Ebend- xx 1,300.Oksi
Fc - Prll
1,300.0 psi
Eminbend - xx 470.Oksi
Wood Species Hem -Fir
Fc - Perp
405.0 psi
Wood Grade No.2
Fv
150.0 psi
Ft
525.0 psi
Density 26.840 pcf
Beam Bracing Beam is Fully Braced against lateral -torsional buckling
Repetitive Member Stress Increase
.019995
Span = 7.50 ft
Applied Loads
Service loads entered. Load Factors will be applied for calculations.
Beam self weight NOT internally calculated and added
Uniform Load : D = 0.0150, L =
0.0550 ksf, Tributary Width
= 1.333 ft
DESIGN SUMMARY
•
Maximum Bending Stress Ratio
= 0.511: 1
Maximum Shear Stress Ratio =
0.270 : 1
Section used for this span
2x8
Section used for this span
2x8
fb: Actual
= 599.14psi
fv: Actual =
40.51 psi
Fb: Allowable
= 1,173.00psi
Fv: Allowable =
150.00 psi
Load Combination
+D+L
Load Combination
+D+L
Location of maximum on span
= 3.750ft
Location of maximum on span =
6.898 ft
Span # where maximum occurs
= Span # 1
Span # where maximum occurs =
Span # 1
Maximum Deflection
Max Downward Transient Deflection
0.085 in Ratio =
1061 > 360 Span: 1 : L Only
Max Upward Transient Deflection
0 in Ratio =
0 <360 n/a
Max Downward Total Deflection
0.108 in Ratio =
834 > 240 Span: 1 : +D+L
Max Upward Total Deflection
0 in Ratio =
0 <240 n/a
Maximum Forces & Stresses for Load Combinations
Load Combination
Max Stress a ios
omen
Values
bnear
Values
Segment Length
Span#
M
V
Cd CF/V
Ci
Cr
Cm
Ct
CL
M
fb
F'b
V
fv
F'v
D Only
0.00
0.00
0.00
0.00
Length = 7.50 ft
1
0.122
0.064
0.90 1.200
1.00
1.15
1.00
1.00
1.00
0.14
128.39
1055.70
0.06
8.68
135.00
+D+L
1.200
1.00
1.15
1.00
1.00
1.00
0.00
0.00
0.00
0.00
Length = 7.50 ft
1
0.511
0.270
1.00 1.200
1.00
1.15
1.00
1.00
1.00
0.66
599.14
1173.00
0.29
40.51
150.00
+D+0.750L
1.200
1.00
1.15
1.00
1.00
1.00
0.00
0.00
0.00
0.00
Length = 7.50 ft
1
0.328
0.174
1.25 1.200
1.00
1.15
1.00
1.00
1.00
0.53
481.45
1466.25
0.24
32.56
187.50
+0.60D
1.200
1.00
1.15
1.00
1.00
1.00
0.00
0.00
0.00
0.00
Length = 7.50 ft
1
0.041
0.022
1.60 1.200
1.00
1.15
1.00
1.00
1.00
0.08
77.03
1876.80
0.04
5.21
240.00
Overall Maximum Deflections
Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+L 1 0.1079 3.777 0.0000 0.000
Project Title:
Engineer:
Project ID:
Project Descr:
Wood Beam
Project File: DEBI WOLLA ENECALC.ec6
LIC# : KW-06014809, Build:20.22.5.16
Wilson & HAJ Consultant Engineers,
LLC
(c) ENERCALC INC 1983-2022
DESCRIPTION: J28
Maximum Deflections for Load Combinations
Load Combination
Span
Max. Downward Defl
Location in Span
Max. Upward Defl
Location in Span
D Only
1
0.0231 in
3.777 ft
0.0000 in
0.000 ft
+D+L
1
0.1079 in
3.777 ft
0.0000 in
0.000 ft
+D+0.750L
1
0.0867 in
3.777 ft
0.0000 in
0.000 ft
+0.60D
1
0.0139 in
3.777 ft
0.0000 in
0.000 ft
L Only
1
0.0848 in
3.777 ft
0.0000 in
0.000 ft
Vertical Reactions
Support notation : Far left is #1
Values in KIPS
Load Combination
Support 1 Support 2
Overall MAXimum
0.350 0.350
Overall MINimum
0.275 0.275
D Only
0.075 0.075
+D+L
0.350 0.350
+D+0.750L
0.281 0.281
+0.60D
0.045 0.045
L Only
0.275 0.275
Project Title:
Engineer:
Project ID:
Project Descr:
Wall Footing
Project File: DEBI WOLLA ENECALC.ec6
LIC# : KW-06014809, Build:20.22.5.16
Wilson & HIM Consultant Engineers, LLC (c) ENERCALC INC 1983-2022
DESCRIPTION: CONCRETE WALL FOOTING; FOR GARAGE TIBUTARY WIDTH=24FT/2
Code References
Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16
Load Combinations Used : ASCE 7-16
General Information
Material Properties
Soil Design Values
f'c : Concrete 28 day strength =
2.50 ksi Allowable Soil Bearing =
1.50 ksf
fy : Rebar Yield =
60.0 ksi Increase Bearing By Footing Weight =
Yes
Ec : Concrete Elastic Modulus =
3,122.0 ksi Soil Passive Resistance (for Sliding) =
250.0 pcf
Concrete Density =
145.0 pcf Soil/Concrete Friction Coeff. =
0.30
(P Values Flexure =
0.90
Shear =
0.750 Increases based on footing Depth
Analysis Settings
Reference Depth below Surface
1.50 ft
Min Steel % Bending Reinf. =
Allow. Pressure Increase per foot of depth -
ksf
Min Allow % Temp Reinf. =
0.00180 when base footing is below =
ft
Min. Overturning Safety Factor =
1.0: 1 Increases based on footing Width
Min. Sliding Safety Factor =
1.0 : 1 Allow. Pressure Increase per foot of width =
ksf
AutoCalc Footing Weight as DL :
Yes when footing is wider than =
ft
Adjusted Allowable Bearing Pressure =
1.597 ksf
Dimensions
Reinforcing
Footing Width = 1.333 ft
Footing Thickness = 8.0 in Bars along X-X Axis
Wall Thickness = 8.0 in
Rebar Centerline to Edge of Concrete... Bar spacing
= 9.00
Wall center offset
at Bottom of footing = 3.0 in Reinforcing Bar Size
= # 4
from center of footing = 0 in
a'
Z
--X
4 bars @ 9 in oc
a^
X-X Section Looking to +Z
Applied Loads
P : Column Load =
OB : Overburden =
V-x =
M-zz =
Vx applied =
D Lr L S W E H
0.5110 0.240
in above top of footing
0.360 0.1920
k
ksf
k
k-ft
Project Title:
Engineer:
Project ID:
Project Descr:
Wall Footing
Project File: DEBI WOLLA ENECALC.ec6
LIC# : KW-06014809, Build:20.22.5.16
Wilson
& HAJ Consultant Engineers,
LLC
(c) ENERCALC
INC 1983-2022
DESCRIPTION: CONCRETE
WALL FOOTING;
FOR GARAGE TIBUTARY WIDTH=24FT/2
DESIGN SUMMARY
- . •
Factor of Safety
Item
Applied
Capacity
Governing Load Combination
PASS n/a
Overturning - Z-Z
0.0 k-ft
0.0 k-ft
No Overturning
PASS n/a
Sliding - X-X
0.0 k
0.0 k
No Sliding
PASS n/a
Uplift
0.0 k
0.0 k
No Uplift
Utilization Ratio
Item
Applied
Capacity
Governing Load Combination
PASS 0.4698
Soil Bearing
0.7501 ksf
1.597 ksf
+D+S
PASS 0.01066
Z Flexure (+X)
0.05995 k-ft
5.624 k-ft
+1.20D+1.60S+0.50W
PASS 0.004264
Z Flexure (-X)
0.02398 k-ft
5.624 k-ft
+0.90D
PASS n/a
1-way Shear (+X)
0.0 psi
75.0 psi
n/a
PASS 0.0
1-way Shear (-X)
0.0 psi
0.0 psi
n/a
Detailed Results
Soil Bearing
Rotation Axis &
Actual Soil Bearing Stress
Actual / Allowable
Load Combination...
Gross Allowable
Xecc
-X
+X
Ratio
D Only
1.597 ksf
0.0 in
0.480 ksf
0.480 ksf
0.301
+D+Lr
1.597 ksf
0.0 in
0.6601 ksf
0.6601 ksf
0.413
+D+S
1.597 ksf
0.0 in
0.7501 ksf
0.7501 ksf
0.470
+D+0.750Lr
1.597 ksf
0.0 in
0.6150 ksf
0.6150 ksf
0.385
+D+0.750S
1.597 ksf
0.0 in
0.6826 ksf
0.6826 ksf
0.428
+D+0.60W
1.597 ksf
0.0 in
0.5664 ksf
0.5664 ksf
0.355
+D+0.750Lr+0.45OW
1.597 ksf
0.0 in
0.6799 ksf
0.6799 ksf
0.426
+D+0.750S+0.450W
1.597 ksf
0.0 in
0.7474 ksf
0.7474 ksf
0.468
, +0.60D+0.60W
1.597 ksf
0.0 in
0.3744 ksf
0.3744 ksf
0.235
, +0.60D
1.597 ksf
0.0 in
0.2880 ksf
0.2880 ksf
0.180
Overturning Stability
Units: k-ft
Rotation Axis &
Load Combination...
Overturning Moment
Resisting Moment
Stability Ratio Status
Footing Has NO Overturning
Sliding Stability
Force Application Axis
Load Combination...
Sliding
Force
Resisting Force
Sliding SafetyRatio Status
Footing Has NO Sliding
Footing Flexure
Flexure Axis & Load Combination Mu Which Tension @ Bot. As Req'd
Gvrn. As
Actual As
Phi"Mn
k-ft
Side ?
or Top ?
inA2
inA2
inA2
k-ft Status
+1.40D
0.0373
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.40D
0.0373
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.20D+0.50Lr
0.03697
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.20D+0.50Lr
0.03697
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.20D+0.50S
0.03946
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
, +1.20D+0.50S
0.03946
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
, +1.20D+1.60Lr
0.04796
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
, +1.20D+1.60Lr
0.04796
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
, +1.20D+1.60Lr+0.50W
0.05195
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
, +1.20D+1.60Lr+0.50W
0.05195
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.20D+1.60S
0.05595
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.20D+1.60S
0.05595
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.20D+1.60S+0.50W
0.05995
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
, +1.20D+1.60S+0.50W
0.05995
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.20D+0.50Lr+W
0.04496
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.20D+0.50Lr+W
0.04496
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
, +1.20D+0.50S+W
0.04746
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
, +1.20D+0.50S+W
0.04746
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
, +0.90D+W
0.03197
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
, +0.90D+W
0.03197
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.20D+0.20S
0.03497
-X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
+1.20D+0.20S
0.03497
+X
Bottom
0.1728
Min Temp %
0.2667
5.624
OK
Project Title:
Engineer:
Project ID:
Project Descr:
Wall Footing
Project File: DEBI WOLLA ENECALC.ec6
LIC# : KW-06014809, Build:20.22.5.16
Wilson & HAJ Consultant Engineers, LLC
(c) ENERCALC INC 1983-2022
DESCRIPTION: CONCRETE
WALL FOOTING; FOR GARAGE TIBUTARY WIDTH=24FT/2
Footing Flexure
Flexure Axis & Load Combination Mu Which Tension @ Bot.
As Req'd Gvrn. As
Actual As
Phi*Mn
k-ft Side ?
or Top ?
in^2 in"2
in"2
k-ft Status
+0.90D
0.02398 -X
Bottom
0.1728 Min Temp
%
0.2667
5.624 OK
+0.90D
0.02398 +X
Bottom
0.1728 Min Temp
%
0.2667
5.624 OK
One Way Shear
Units : k
Load Combination...
Vu @ -X Vu @ +X
Vu:Max Phi Vn
Vu / Phi*Vn
Status
+1.40D
0 psi
0 psi
0 psi
75 psi
0
OK
+1.20D+0.50Lr
0 psi
0 psi
0 psi
75 psi
0
OK
+1.20D+0.50S
0 psi
0 psi
0 psi
75 psi
0
OK
+1.20D+1.60Lr
0 psi
0 psi
0 psi
75 psi
0
OK
+1.20D+1.60Lr+0.50W
0 psi
0 psi
0 psi
75 psi
0
OK
+1.20D+1.60S
0 psi
0 psi
0 psi
75 psi
0
OK
+1.20D+1.60S+0.50W
0 psi
0 psi
0 psi
75 psi
0
OK
+1.20D+0.50Lr+W
0 psi
0 psi
0 psi
75 psi
0
OK
+1.20D+0.50S+W
0 psi
0 psi
0 psi
75 psi
0
OK
+0.90D+W
0 psi
0 psi
0 psi
75 psi
0
OK
+1.20D+0.20S
0 psi
0 psi
0 psi
75 psi
0
OK
+0.90D
0 psi
0 psi
0 psi
75 psi
0
OK