Loading...
APPROVED ENG BLD-RESUB1 BLD2023-0153 ARCH PLANS (REC'D VIA EMAIL 4.3.23)r nay APPROVAL STAMP PAGE PLEASE KEEP WITH THE PLANS RESUB PERMITTING & DEVELOPMENT Apr 03 2023 BUILDING DIVISION REVISIONS CITY OF EDMONDS DEVELOPMENT SERVICES 121 5th Avenue N REV1 DEPARTMENT P: 425.771.0220 REV REVS www.edmondswa.gov REW REVS City Of Edmonds Building Department Work r DECK Address. 717 PINE ST Owner LANE ------------------ 23 Approved Date ---- -- Building Official: B 00/K %EG� Permit Number, BLD2023-0153 ------------------------------ APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE ENGINEERING DIVISION APPROVED AS NOTED jd] j#44t4+ttu 04/13/2023 VV NOTE- This Stamp page must remain with the city approved plans at all times. Failure to have this Stamp page with the City approved plans could result in delay of the inspections including the FINAL inspection. If lost please contact the city as soon as possible to find a solution. Thank You. RESUB V - Apr 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 6LD202.. ,. y CIA X r + 4m is I Where the height of the I I deck posts exceed 4' I knee bracing is I I required. Install knee "`� i bracing in '-I'�- ' accordance with ' mybuildingp ermit.com sheet 7 of the deck tip I sheet #5. - C t4 r I hold down I ten' ion devices I for ` #eral loads I are required in I ac 'ordance with I 20t IRC figure I R5.9.2(2) The loca ion is ' 'do- ndent on ' therpe of ten ion device Luser. a Lam„ RESUB Apr 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DECK GUARDRAIL PER *ft{t" 'r--- BEAM PER PLAN (2)1/2" 0 HDG BOLTS - EA. GUARDRAIL POST �f� X ABC, Cps e. DECK JOISTS PER PLAN DTT2 EA. GUARDRAIL POST (2) BAYS FULL -DEPTH 2x BLKG. W/ A35 EA. END OF EA. BLOCK Typical Deck w/ Guardrail Detail 0 SS K-5 RESUB Apr 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DECK GUARDRAIL X INVERTED LUS HANGER ,QER AR@1 . (48"oc max.) E DTT2Z EA, GUARDRAIL CL POST DECKING PER ARCH. P.T. DECK JOISTS (2) 1/2" 0 HDG BOLTS PER PLAN EA, GUARDRAIL POSTME cV CV� A35 ® 48"oe CONT. P.T. 4x RIM (2) 16d EA. JOIST *P.T. 2x BLOCKING *PROVIDE H3 CUPS TO BM. AT EA. JOIST IN LIEU OF BLKG. & BM. PER PLAN A35 CLIPS WHERE REQ'D FOR TREX RAIN ESCAPE POST PER PLAN Typical Cantilevered Deck w/ Guardrail Detail S S K-4 RESUB Apr 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT I Where the height of the deck posts exceed I 4' knee bracing is required. Install knee I bracing in accordance with I mybuildingpermit.com sheet 7 of the deck I tip sheet #5.------------------- I � POST, PLINTH, & FTG. )ST PER PLAN 3SQ SERIES DST BASE Deck or Canopy Post Footing - Square Plinth SS K-2 RESUB Apr 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT fr4"11 �-) Qv WATERPROOFING P.T. 2x LEDGER TO MATCH — DECK FRAMING (U.N.O.) W/ (2) ROWS SDS1/4x3�/2 SCREWS 0 3"oc, STAGGERED LUS SERIES HANGER Vol )( 0 r 6AjP* e(ee 40 7 —I P.T. DECK JOISTS PER PLAN ALL FASTENERS INTO PRESSURE TREATED WOOD SHALL BE GALV. OR STAINLESS STEEL PER GENERAL NOTES ----------------------� I hold down tension devices for lateral loads are required in accordance with 2018 IRC figure I R57.9.2(2) The location is dependent on the type of tension device used. - L--------------------- E)FLOOR FRAMING 5" max. SDS Screw Spacing Elevation NOTE; LEDGER FASTENER SPACING MAY BE OFFSET UP TO 3" TO AVOID INTERFERENCE W/ JOIST HANGER Typical Deck Ledger Detail E E SSK-3 RESUB Apr 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HUCQ W/ SDS 114x4-112" F SCREWS TO LEDGER SSK-3 )0 ........ .............. P.T. LEDGER iD1 i w SSK-5 _ N V F- 0. 2'-0" TYP. 2'-0"sq.x8"dp. FTG. W/ (2)#4 BOT. EA. WAY U O r� v N X N V I.-: h a a P.T. 6x12 41 SSK-4 Deck Framing Plan Notes: 1.Do not scale drawings. 25'-6" HUCQ W1 SIDS 114x4-112" HUCQ WI SOS 114x4-112" SCREWS TO LEDGER SCREWS TO LEDGER ...................................... P.T. 2x12 LEDGER HUC P.T.4x12 P HUC SSK-5 Y U O U N O NC11h N d a a SSK-2 2'-6"sq.x8"dp. FTG. WI (3)#4 BOT. EA. WAY DECK FRAMING PLAN 2.Deck framing shall be P.T. 2x12 HemFir No. 2 at 12" o.c. P.T. 6x12 PQ G /CIt'ZIPP 2'-0"sq.x8"dp. FTG. W/ (2)#4 BOT. EA. WAY 3.The bottom of all exterior footings shall be 18" minimum below grade. 4.Refer to General Structural Notes for additional requirements. .4` �-P,J�-0 V Lt:71� SSK-1 RESUB Apr 03 2023 CITY OF EDMONDS DEVELOPMENTSERVIAEj�L WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 40 BAR DEPARTMENT DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN ACCORDANCE WITH ACT 318-14, CLASS B. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. 17. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER) . . . . 2" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS OR SMALLER). . 1-1/2" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS . . . . . . . . . . . . . 1-1/2" SLABS AND WALLS (INT. FACE). . GREATER OF BAR DIAMETER PLUS 1/8" OR 3/4" ANCHORAGE 18. EXPANSION BOLTS INTO CONCRETE SHALL BE "STRONG -BOLT 2" WEDGE ANCHORS AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY AND INSTALLED IN STRICT CONFORMANCE TO ICC-ES REPORT NUMBER ESR-3037, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. BOLTS INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. PERIODIC SPECIAL INSPECTION IS REQUIRED TO VERIFY ANCHOR TYPE, ANCHOR DIMENSIONS, ANCHOR LOCATION, TIGHTENING TORQUE, HOLE DIMENSIONS, ANCHOR EMBEDMENT, AND ADHERENCE TO THE INSTALLATION INSTRUCTIONS. 19. CONCRETE SCREW ANCHORS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE "TITEN HD" HEAVY DUTY SCREW ANCHOR AS MANUFACTURED BY THE SIMPSON STRONG - TIE COMPANY, INSTALLED IN STRICT ACCORDANCE WITH ICC-ES REPORT NO. ESR- 2713 (CONCRETE), NO. ESR-1056 (CMU), INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. SCREW ANCHORS INTO CONCRETE MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SPECIAL0,DRI S REQUIRED. 20. FRAMING LUMBER SHALL BE S-MC-19, AND GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD No. 17, GRADING RULES FOR WEST COAST LUMBER, 2038, OR WWPA STANDARD, WESTERN LUMBER GRADING RULES 2017. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS (2X & 3X MEMBERS) HEM -FIR NO. 2 AND BEAMS MINIMUM BASE VALUE, Fb = 850 PST (4X MEMBERS) DOUGLAS FIR -LARCH NO. I MINIMUM BASE VALUE, Fb = 1000 PSI BEAMS (INCL. 6X AND LARGER) DOUGLAS FIR -LARCH NO. 1 MINIMUM BASE VALUE, Fb = 1350 PSI POSTS (4X MEMBERS) DOUGLAS FIR -LARCH NO. 2 MINIMUM BASE VALUE, Fc = 1350 PSI (6X AND LARGER) DOUGLAS FIR -LARCH NO. 1 MINIMUM BASE VALUE, Fc = 1000 PSI STUDS, PLATES & MISC. FRAMING: DOUGLAS FIR -LARCH NO. 2 OR HEM -FIR NO. 2 21. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR S RUCTURAL IT, EXTERIOR GLUE IN CONFORMANCE WITH DOC PS 1 OR PS 2. ORIENTE STRAND BOARD RESUB Apr 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT