REVIEWED-BLD2023-0153+STRUCTURAL PLANS & CALCS+2.3.2023_3.17.55_PM+3350944..............REVIEWED........... ........., BY CITY OF EDMONDS BUILDING DEPARTMENT!! Structural Drawings & Calculations For: Lane Deck 717 Pine Street Edmonds, WA 98020 •21 Prepared for: Dave Lane Job #: 11068-2021-01 Date: 5/28/2021 SEATTLE 2124 Third Ave, Suite 100, Seattle, WA 98121 0 206-443-6212 ssfengineers-com Ic»WHme MG TACOMA 934 Broadway, Suite 100, Tacoma, WA 98402 0 253,284,9470 CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (2018 EDITION). 2. DESIGN LOADING CRITERIA: HANDRAILS AND GUARDS GUARDRAILS/BALCONY RAILS CONCENTRATED LOAD . . . . . . . . . . 200 LBS RESIDENTIAL - ONE AND TWO-FAMILY DWELLINGS FLOOR LIVE LOAD . . . . . . . . . . . . . . . . . . . . . . . . 40 PSF MISCELLANEOUS LOADS DECKS . . . . . . . . . . . . . . . . . . . . . . . . 1.5 x AREA SERVED DEFLECTION CRITERIA LIVE LOAD DEFLECTION . . . . . . . . . . . . . . . . . . . . . L/360 TOTAL LOAD DEFLECTION . . . . . . . . . . . . . . . . . . . . . L/240 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. ARCHITECTURAL DRAWINGS ARE THE PRIME CONTRACT DRAWINGS. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE SPECIFICATION, THESE GENERAL NOTES AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. 4. PRIMARY STRUCTURAL ELEMENTS NOT DIMENSIONED ON THE STRUCTURAL PLANS AND DETAILS SHALL BE LOCATED BY THE ARCHITECTURAL PLANS AND DETAILS. VERTICAL DIMENSION CONTROL IS DEFINED BY THE ARCHITECTURAL WALL SECTIONS, BUILDING SECTION, AND PLANS. DETAILING AND SHOP DRAWING PRODUCTION FOR STRUCTURAL ELEMENTS WILL REQUIRE DIMENSIONAL INFORMATION CONTAINED IN BOTH ARCHITECTURAL AND STRUCTURAL DRAWINGS. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. CONFORM TO ASCE 37-14 "DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION". 7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. ALL TYPICAL NOTES AND DETAILS SHOWN ON DRAWINGS SHALL APPLY, UNLESS NOTED OTHERWISE. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED ON THE PLANS BUT SHALL STILL APPLY AS SHOWN OR DESCRIBED IN THE DETAILS. WHERE TYPICAL DETAILS ARE NOTED ON THE PLANS, THE SPECIFIED TYPICAL DETAIL SHALL BE USED. WHERE NO TYPICAL DETAIL IS NOTED, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CHOOSE THE APPROPRIATE TYPICAL DETAIL FROM THOSE PROVIDED OR REQUEST ADDITIONAL INFORMATION. THE CONTRACTOR SHALL SUBMIT ALL PROPOSED ALTERNATE TYPICAL DETAILS TO THOSE PROVIDED WITH RELATED CALCULATIONS TO THE ENGINEER FOR APPROVAL PRIOR TO SHOP DRAWING PRODUCTION AND FIELD USE. GEOTECHNICAL 9. FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER OR APPROVED BY THE BUILDING OFFICIAL. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED GRADE. UNLESS OTHERWISE NOTED, FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. ALLOWABLE SOIL PRESSURE . . . . . . . . . . . . . . . . . . . . . . 1500 PSF RENOVATION 10. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. 11. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER IF EXISTING CONDITIONS DETERMINED DURING WORK VARY FROM THE EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS. 12. CONTRACTOR SHALL CHECK FOR DRY ROT AT ALL AREAS OF NEW WORK. ALL ROT SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY THE STRUCTURAL ENGINEER OR ARCHITECT. CONCRETE 13. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH ACI 301, INCLUDING TESTING PROCEDURES. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH OF f'c = 3,000 PSI AND MIX SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC YARD AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. REQUIRED CONCRETE STRENGTH IS BASED ON THE DURABILITY REQUIREMENTS OF SECTION 1904 OF THE IBC. DESIGN STRENGTH IS f'c = 2,500 PSI. 14. ALL CONCRETE WITH SURFACES EXPOSED TO WEATHER OR STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494, AND C618. TOTAL AIR CONTENT FOR FROST -RESISTANT CONCRETE SHALL BE IN ACCORDANCE WITH ACI 318-14, TABLE 19.3.2.1 MODERATE EXPOSURE, Fl. 15. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, FY = 60,000 PSI. 16. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN ACCORDANCE WITH ACI 315R-18 AND 318-14. LAP ALL CONTINUOUS REINFORCEMENT #5 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN ACCORDANCE WITH ACI 318-14, CLASS B. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. 17. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1v FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER) . . . . 2" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS OR SMALLER). . 1-1/2" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS . . . . . . . . . . . . . 1-1/2" SLABS AND WALLS (INT. FACE). GREATER OF BAR DIAMETER PLUS 1/8" OR 3/4" ANCHORAGE 18. EXPANSION BOLTS INTO CONCRETE SHALL BE "STRONG -BOLT 2" WEDGE ANCHORS AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY AND INSTALLED IN STRICT CONFORMANCE TO ICC-ES REPORT NUMBER ESR-3037, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. BOLTS INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. PERIODIC SPECIAL INSPECTION IS REQUIRED TO VERIFY ANCHOR TYPE, ANCHOR DIMENSIONS, ANCHOR LOCATION, TIGHTENING TORQUE, HOLE DIMENSIONS, ANCHOR EMBEDMENT, AND ADHERENCE TO THE INSTALLATION INSTRUCTIONS. 19. CONCRETE SCREW ANCHORS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE "TITEN HD" HEAVY DUTY SCREW ANCHOR AS MANUFACTURED BY THE SIMPSON STRONG - TIE COMPANY, INSTALLED IN STRICT ACCORDANCE WITH ICC-ES REPORT NO. ESR- 2713 (CONCRETE), NO. ESR-1056 (CMU), INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. SCREW ANCHORS INTO CONCRETE MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SPECIAL INSPECTION IS REQUIRED. WOOD 20. FRAMING LUMBER SHALL BE S-DRY, KD, OR MC-19, AND GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD No. 17, GRADING RULES FOR WEST COAST LUMBER, 2018, OR WWPA STANDARD, WESTERN LUMBER GRADING RULES 2017. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS (2X & 3X MEMBERS) AND BEAMS (4X MEMBERS) BEAMS (INCL. 6X AND LARGER) POSTS (4X MEMBERS) (6X AND LARGER) STUDS, PLATES & MISC. FRAMING HEM -FIR NO. 2 MINIMUM BASE VALUE, Fb = 850 PSI DOUGLAS FIR -LARCH NO. 1 MINIMUM BASE VALUE, Fb = 1000 PSI DOUGLAS FIR -LARCH NO. 1 MINIMUM BASE VALUE, Fb = 1350 PSI DOUGLAS FIR -LARCH NO. 2 MINIMUM BASE VALUE, Fc = 1350 PSI DOUGLAS FIR -LARCH NO. 1 MINIMUM BASE VALUE, Fc = 1000 PSI DOUGLAS FIR -LARCH NO. 2 OR HEM -FIR NO. 2 21. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH DOC PS 1 OR PS 2. ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. ROOF SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 32/16. FLOOR SHEATHING SHALL BE 3/4" (NOMINAL) WITH SPAN RATING 48/24. WALL SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 24/0. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SHEATHING. REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING REQUIREMENTS. 22. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE - TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY. 23. PRESERVATIVE TREATED WOOD SHALL BE TREATED PER AWPA STANDARD Ul TO THE USE CATEGORY EQUAL TO OR HIGHER THAN THE INTENDED APPLICATION. TREATED WOOD FOR ABOVE GROUND USE SHALL BE TREATED TO AWPA UC3B. WOOD IN CONTINUOUS CONTACT WITH FRESH WATER OR SOIL SHALL BE TREATED TO AWPA UC4A. WOOD FOR USE IN PERMANENT FOUNDATIONS SHALL BE TREATED TO AWPA UC4B. 24. WOOD TREATED FOR FIRE RESISTANCE SHALL MEET THE REQUIREMENTS OF ASTM E84 OR UL 723 AND HAVE A LISTED FLAME SPREAD INDEX OF 25 OR LESS. FIRE RETARDANT TREATED LUMBER AND WOOD STRUCTURAL PANELS SHALL BE LABELED IN ACCORDANCE WITH IBC 2303.2.4. WOOD TREATED FOR FIRE PROTECTION FOR USE IN INTERIOR ABOVE GROUND CONSTRUCTION AND CONTINUOUSLY PROTECTED FROM WEATHER AND OTHER SOURCES OF MOISTURE SHALL BE TREATED TO AWPA UCFA. WOOD TREATED FOR FIRE PROTECTION FOR USE IN EXTERIOR ABOVE GROUND CONSTRUCTION AND SUBJECT TO WETTING OR OTHER SOURCES OF MOISTURE SHALL BE TREATED TO AWPA UCFB. 25. FASTENERS AND TIMBER CONNECTORS USED WITH TREATED WOOD SHALL HAVE CORROSION RESISTANCE AS INDICATED IN THE FOLLOWING TABLE, UNLESS OTHERWISE NOTED. WOOD TREATMENT CONDITION PROTECTION HAS NO AMMONIA CARRIER INTERIOR DRY G90 GALVANIZED CONTAINS AMMONIA CARRIER INTERIOR DRY G185 OR A185 HOT DIPPED OR CONTINUOUS HOT -GALVANIZED PER ASTM A653 CONTAINS AMMONIA CARRIER INTERIOR WET TYPE 304 OR 316 STAINLESS CONTAINS AMMONIA CARRIER EXTERIOR TYPE 304 OR 316 STAINLESS AZCA ANY TYPE 304 OR 316 STAINLESS INTERIOR DRY CONDITIONS SHALL HAVE WOOD MOISTURE CONTENT LESS THAN 190. WOOD MOISTURE CONTENT IN OTHER CONDITIONS (INTERIOR WET, EXTERIOR WET, AND EXTERIOR DRY) IS EXPECTED TO EXCEED 190. CONNECTORS AND THEIR FASTENERS SHALL BE THE SAME MATERIAL. COMPLY WITH THE TREATMENT MANUFACTURERS RECOMMENDATIONS FOR PROTECTION OF METAL. 26. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER C-C-2019. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER FOR MAXIMUM LOAD CARRYING CAPACITY. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ALL 2X JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST HANGERS. ALL TJI JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "ITS" SERIES JOIST HANGERS. ALL DOUBLE -JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "MIT" SERIES JOIST HANGERS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM)AS MEMBERS CONNECTED. 27. WOOD FASTENERS A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER 6d 2" 0.113" 8d 2-1/2" 0.131" 10d 3" 0.148" 12d 3-1/4" 0.148" 16d BOX 3-1/2" 0.135" IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW AND APPROVAL. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END. B. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD. INSTALLATION OF LAG BOLTS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60 TO 70 PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" AND SMALLER LAG SCREWS. 28. NOTCHES AND HOLES IN WOOD FRAMING: A. NOTCHES ON THE ENDS OF SOLID SAWN JOISTS AND RAFTERS SHALL NOT EXCEED ONE-FOURTH THE JOIST DEPTH. NOTCHES IN THE TOP OR BOTTOM OF SOLID SAWN JOISTS SHALL NOT EXCEED ONE -SIXTH THE DEPTH AND SHALL NOT BE LOCATED IN THE MIDDLE THIRD OF THE SPAN. HOLES BORED IN SOLID SAWN JOISTS AND RAFTERS SHALL NOT BE WITHIN 2 INCHES OF THE TOP OR BOTTOM OF THE JOIST, AND THE DIAMETER OF ANY SUCH HOLE SHALL NOT EXCEED ONE-THIRD THE DEPTH OF THE JOIST. B. IN EXTERIOR WALLS AND BEARING PARTITIONS, ANY WOOD STUD IS PERMITTED TO BE CUT OR NOTCHED TO A DEPTH NOT EXCEEDING 25 PERCENT OF ITS WIDTH. A HOLE NOT GREATER IN DIAMETER THAN 40 PERCENT OF THE STUD WIDTH IS PERMITTED TO BE BORED IN ANY WOOD STUD. IN NO CASE SHALL THE EDGE OF THE BORED HOLE BE NEARER THAN 5/8 INCH TO THE EDGE OF THE STUD. BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A CUT OR NOTCH. C. NOTCHES AND HOLES IN MANUFACTURED LUMBER AND PREFABRICATED PLYWOOD WEB JOISTS SHALL BE PER THE MANUFACTURERS RECOMMENDATIONS UNLESS OTHERWISE NOTED. 29. WOOD FRAMING NOTES --THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE AITC "TIMBER CONSTRUCTION MANUAL" AND THE AWC "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO IBC TABLE 2304.10.1. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. B. WALL FRAMING: REFER ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS. ALL STUDS SHALL BE SPACED AT 16" O.C. UNO. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AND AT BEAM OR HEADER BEARING LOCATIONS. TWO 2x8 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE CONTINUOUS SOLID BLOCKING AT MID -HEIGHT OF ALL STUD WALLS OVER 10'-0" IN HEIGHT. ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH TWO 16d NAILS, AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16d NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16d @ 12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE EIGHT 16d NAILS @ 4" O.C. EACH SIDE JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH TWO ROWS OF 16d NAILS @ 12" ON -CENTER, OR ATTACHED TO CONCRETE BELOW WITH 5/8" DIAMETER ANCHOR BOLTS @ 4'-0" ON -CENTER EMBEDDED 7" MINIMUM, UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH TWO ROWS OF 16d @12" ON -CENTER. UNLESS OTHERWISE NOTED, GYPSUM WALLBOARD SHALL BE FASTENED TO THE INTERIOR SURFACE OF ALL STUDS AND PLATES WITH NO. 6 X 1-1/4" TYPE S OR W SCREWS @ 8" ON -CENTER. UNLESS INDICATED OTHERWISE, 1/2" (NOMINAL)APA RATED SHEATHING (SPAN RATING 24/0) SHALL BE NAILED TO ALL EXTERIOR SURFACES WITH 8d NAILS @ 6" ON -CENTER AT PANEL EDGES AND TOP AND BOTTOM PLATES (BLOCK UN -SUPPORTED EDGES)AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH 8d NAILS @ 12" ON -CENTER ALLOW 1/8" SPACING AT ALL PANEL EDGES AND PANEL ENDS. C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE JOIST LENGTH AND AROUND ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE SOLID BLOCKING AT ALL BEARING POINTS. TOE -NAIL JOISTS TO SUPPORTS WITH TWO 16d NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH SIMPSON METAL JOIST HANGERS IN ACCORDANCE WITH NOTES ABOVE. NAIL ALL MULTI JOIST BEAMS TOGETHER WITH TWO ROWS 16d @ 12" ON -CENTER. UNLESS OTHERWISE NOTED ON THE PLANS, PLYWOOD ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH GRAIN PERPENDICULAR TO SUPPORTS AND NAILED AT 6" ON -CENTER WITH 8d NAILS TO FRAMED PANEL EDGES, STRUTS AND OVER STUD WALLS AS SHOWN ON PLANS AND @ 12" ON -CENTER TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH 16d @ 12" ON -CENTER UNLESS OTHERWISE NOTED. 25'-6" HUCQ W/ SDS 1/4x4-1/2" HUCQ W/ SDS 1/4x4-1/2" HUCQ W/ SDS 1/4x4-1/2" SCREWS TO LEDGER SCREWS TO LEDGER SCREWS TO LEDGER SSK-3 ....................... ...................................................... P.T. 2x12 LEDGER P.T. 2x12 LEDGER C 7 HUC P.T.4x12 P HUC SSK-5 O U N O X N U O U O N ��`` @ N d N V 1X V T< N (V ~ N d d a 2'-0" TYP. q------- - P.T. 6x12 P.T. 6x12 ® G SSK-4 SSK-2 2'-0"sq.x8"dp. FTG. W/ 2'-6"sq.x8"dp. FTG. W/ �6 g4� 2'-0"sq.x8"dp. FTG. W/ Q (2)#4 BOT. EA. WAY (3)#4 BOT. EA. WAY 0 (2)#4 BOT. EA. WAY DECK FRAMING PLAN Deck Framing Plan Notes: 1.Do not scale drawings. 2.Deck framing shall be P.T. 2x12 HemFir No. 2 at 12" o.c. 3.The bottom of all exterior footings shall be 18" minimum below grade. 4.Refer to General Structural Notes for additional requirements. SSK-5 v SSK-1 � POST, PLINTH, & FTG. )ST PER PLAN BSQ SERIES DST BASE E Deck or Canopy Post Footing - Square Plinth SSK-2 WATERPROOFING PER ARCH. P.T. 2x LEDGER TO MATCH DECK FRAMING (U.N.O.) W/ (2) ROWS SDS1/4x31/2 SCREWS @ Toc, STAGGERED LUS SERIES HANGER DECKING PER ARCH. P.T. DECK JOISTS PER PLAN ALL FASTENERS INTO PRESSURE TREATED WOOD SHALL BE GALV. OR STAINLESS STEEL PER GENERAL NOTES (E)FLOOR FRAMING -ICV ;✓ F Cam_ T T -1N E 4" min. 3"oc 5" max. SDS Screw Spacing Elevation NOTE: LEDGER FASTENER SPACING MAY BE OFFSET UP TO 3" TO AVOID INTERFERENCE W/ JOIST HANGER Typical Deck Ledger Detail SSK-3 DECK GUARDRAIL PER ARCH. (48"oc max.) (2) 1/2" 0 HDG BOLTS EA. GUARDRAIL POST N� L CONT. P.T. 4x RIM *P.T. 2x BLOCKING BM. PER PLAN POST PER PLAN X INVERTED LUS HANGER E DTT2Z EA. GUARDRAIL CL POST DECKING PER ARCH. P.T. DECK JOISTS PER PLAN A35 @ 48"oc* (2) 16d EA. JOIST *PROVIDE H3 CLIPS TO BM. AT EA. JOIST IN LIEU OF BLKG. & A35 CLIPS WHERE REQ'D FOR TREX RAIN ESCAPE Typical Cantilevered Deck w/ Guardrail Detail SS K-4 DECK GUARDRAIL PER ARCH BEAM PER PLAN (2)1/2" 0 HDG BOL EA. GUARDRAIL F [NG PER ARCH. JOISTS PER EA. GUARDRAIL �/-j SAYS FULL- DEPTH 2x BLKG. W/ A35 EA. END OF EA. BLOCK Typical Deck w/ Guardrail Detail SSK-5 Beam JOIST HF 2 x 12 w1= 70 plf R1= 488lbs w2= 70 plf R2= 563 Ibs L1= 14 ft M+= 1,698 lb-ft L2= 1 ft M-= 35 lb-ft X= 7.00 ft Fb= 644 psi P= - Ibs Fv= 38 psi b= 1.50 in Aspan= 0.258 in d= 11.25 in I span/ 650 E= 1,300 ksi Acant= (0.06) in Cv= 1 1.001 1 1 1 cantl 1 (410) R1t w1 L1 w2 t R2 L2 P Beam BEAM PSL 5 1/2 x 11 1/2 w1= 563 plf R1= 3008lbs w2= 80 plf R2= 3,199 Ibs L1= 11 ft M+= 8,045 lb-ft L2= 2 ft M-= 161 lb-ft X= 5.38 ft Fb= 796 psi P= - Ibs Fv= 59 psi b= 5.50 in Aspan= 0.150 in d= 11.50 in I span/ 861 E= 1,600 ksi Acant= (0.09) in Cv= 1.00 1 cant/ (544) R1t w1 L1 w2 t R2 L2 P Beam T. BM. HF 3 x 12 w= 420 plf R= 1,365 Ibs L= 6.5 ft M= 2,218 ft-Ibs b= 3.00 in Fb= 421 psi d= 11.25 in Fv= 43 psi E= 1300 ksi A= 0.04 in Cv= 1 1.00 151.0 1 1 1/1 2140 C? w C� Project: RUCTURAL ENGINEERING Beam T. JOIST DF-L 3 1/2 x 11 1/4 w1= 70 plf R1 = 734 Ibs w2= 70 plf R2 = 1,611 Ibs L1= 12 ft M = 3,809 lb-ft L2= 3 ft Fb = 619 psi X= 11.5 ft Fv = 59 psi P= 1,365 Ibs A= 0.11 in b= 3.50 in I / 1,502 d= 11.25 in Cv= 1.00 E=l 1,700 1 ksi w1 R1 t L1 P w2 L2 R2 Lane Deck Date: 05/28/21 Project #: 2124 Third Avenue. Suite 100. Seattle. WA 98121 www.swensonsayfaqet.com Office: 206.443.6212 Fax: 206.443.4870 Design: ECR Sheet: Spread Footing Soil Bearing Design Service Loads Loading Service Load Factors Dead Load = 1.3 kips Live Load = 4.2 kips Wind/EQ Load = 0.0 kips Win EQ Moment M,= 0 ft-kips Gravity Load Eccentricity (±X)= 0.00 ft. Footing Weight = 0.4 kips Total Load = 5.9 kips Total Moment = 0 ft-kips Column Dimensions and Location Column Xc Dimension (Dx) = 5.50 in. Column Yc Dimension (Dy) = 5.50 in. Column Face from right (Cr) = 0.77 ft. Column Face from left (Cl) = 0.77 ft. Footing Dimensions L Dimension (X) = 2.00 ft. B Dimension (Y) = 2.00 ft. Footing Thickness (t) = 8.00 in. Ftg Overburden (Ot) = 0.00 ft. 0 % STRUCTURAL ENGINEERING DL 1 LL 1 EQ/Wind 1 Soil Properties Allowable Soil Brg. (Qa) = 1.50 ksf Overburdan Density (ys) = 120 psf Net Ftg Wt? (yam y5) No Soil Bearing Check (Allowable) Eccentricity = 0.00 ft. Leng. Soil Brg. Under Ftg.= 2.00 ft. qmax = 1.48 ksf gmin = 1.48 ksf e > L/6 gmax = 4Q 3L(L-2e) gmin = 0 Soil Pressure Equations: e < L/6 Q / 6e\ gmax = LB 1 + L Q ( 6e\ gmin = LB1 L /1 3 -2 Lane Deck PROJECT 2'X2' Footing 3 X 512812021 DATE PROD. # ECR DESIGN fl I� SHEET Spread Footing Concrete Design - ACI 318-14 Footing Properties Concrete Strength (f'c) = 3000 psi Rebar Yield Strength (fy) = 60000 psi Reinforcing Clear Cover (cvr) = 3.00 in. Reinforcing Depth (d) = 4.75 in. Factored Loads Factored Total Load = 8.8 kips Factored Total moment = 0 ft-kips Factored Bearing Eccentricity = 0.00 ft. Length of Soil Brg. Under Ftg. = 2.00 ft. qmax = 2.19 ksf qcolr = 2.19 ksf qcoll = 2.19 ksf qmin = 2.19 ksf Flexural Design - X Direction Bar Size = Bars = #4 2 1 ft-kips Mu = OMn = 8 ft-kips Pmin = 0.0018 Preq = 0.0005 A, Required = 0.21 sq. in. A, Provided = 0.40 sq. in. Controls OK One -Way Shear Design - X Direction Vu = 3 kips OVn = 9 kips OK R = 1.000 Y5= 2/(R+1) = 1.00 Provide A,,regYs= 0.21 sq. in. Provide evenly distributed bars in each direction. Concrete CapacityEquations: Mn=ASFy [d — AsFy i (0. 5f c b)] Vn = 2 y f'c bl,,,d C Aq STRUCTURAL ENGINEERING Strength Load Factors DL 1.2 LL 1.6 EQ/Wind 1 Factored Moments and Shears Mu Vu k-ft kips X Right Side 1 3 X Left Side 1 3 Y Both Sides 1 3 Flexural Design - Y Direction Bar Size = #4 Bars = 2 Mu = 1 ft-kips OMn = 8 ft-kips Pmin = 0.0018 Preq = 0.0005 AS Required = 0.21 sq. in. A, Provided = 0.40 sq. in. Controls OK One -Way Shear Design - Y Direction Vu = 3 kips OVn = 9 kips Two -Way (Punching) Shear Design ba = 41 in vu = 7 kips Ovn = 30 kips 4 f'c 4 vn = min 2 + Q f'c bad \2 + bo) f'C bo = 2(Dx + d) + 2(Dy + d) f3 = max(Dx, Dy)/min(Dx, Dy) OK Lane Deck 512812021 PROJECT 2'X2' Footing DATE PROD. # ECR DESIGN a d Pr uz 0 U) Z SHEET Spread Footing Soil Bearing Design Service Loads Loading Service Load Factors Dead Load = 2.0 kips Live Load = 6.5 kips Wind/EQ Load = 0.0 kips Win EQ Moment M,= 0 ft-kips Gravity Load Eccentricity (±X)= 0.00 ft. Footing Weight = 0.6 kips Total Load = 9.1 kips Total Moment = 0 ft-kips Column Dimensions and Location Column Xc Dimension (Dx) = 5.50 in. Column Yc Dimension (Dy) = 5.50 in. Column Face from right (Cr) = 1.02 ft. Column Face from left (Cl) = 1.02 ft. Footing Dimensions L Dimension (X) = 2.50 ft. B Dimension (Y) = 2.50 ft. Footing Thickness (t) = 8.00 in. Ftg Overburden (Ot) = 0.00 ft. COSTRUCTURAL ENGINEERING DL 1 LL 1 EQ/Wind 1 Soil Properties Allowable Soil Brg. (Qa) = 1.50 ksf Overburdan Density (ys) = 120 psf Net Ftg Wt? (yam y5) No Soil Bearing Check (Allowable) Eccentricity = 0.00 ft. Leng. Soil Brg. Under Ftg.= 2.50 ft. qmax = 1.46 ksf gmin = 1.46 ksf e > L/6 gmax = 4Q 3L(L-2e) gmin = 0 Soil Pressure Equations: e < L/6 Q / 6e\ gmax = LB 1 + L Q ( 6e\ gmin = LB1 L /1 el -2 Lane Deck PROJECT 2.5'x2.5' Footing 3 X 512812021 DATE PROD. # ECR DESIGN fl I� SHEET Spread Footing Concrete Design - ACI 318-14 Footing Properties Concrete Strength (f'c) = 3000 psi Rebar Yield Strength (fy) = 60000 psi Reinforcing Clear Cover (cvr) = 3.00 in. Reinforcing Depth (d) = 4.75 in. Factored Loads Factored Total Load = 13.6 kips Factored Total moment = 0 ft-kips Factored Bearing Eccentricity = 0.00 ft. Length of Soil Brg. Under Ftg. = 2.50 ft. qmax = 2.17 ksf qcolr = 2.17 ksf qcoll = 2.17 ksf qmin = 2.17 ksf Flexural Design - X Direction Bar Size = Bars = #4 3 3 ft-kips Mu = OMn = 12 ft-kips Pmin = 0.0018 Preq = 0.0009 A, Required = 0.26 sq. in. A, Provided = 0.60 sq. in. Controls OK One -Way Shear Design - X Direction Vu = 4 kips OVn = 12 kips OK R = 1.000 Y5= 2/(R+1) = 1.00 Provide A,,regYs= 0.26 sq. in. Provide evenly distributed bars in each direction. Concrete CapacityEquations: Mn=ASFy [d — AsFy i (0. 5f c b)] Vn = 2 y f'c bl,,,d C Aq STRUCTURAL ENGINEERING Strength Load Factors DL 1.2 LL 1.6 EQ/Wind 1 Factored Moments and Shears Mu Vu k-ft kips X Right Side 3 4 X Left Side 3 4 Y Both Sides 3 4 Flexural Design - Y Direction Bar Size = #4 Bars = 3 Mu = 3 ft-kips OMn = 12 ft-kips Pmin = 0.0018 Preq = 0.0009 AS Required = 0.26 sq. in. A, Provl e = 0.60 sq. in. Controls OK One -Way Shear Design - Y Direction Vu = 4 kips OVn = 12 kips OK Two -Way (Punching) Shear Design ba = 41 in vu = 12 kips Ovn = 30 kips 4 f'c 4 vn = min 2 + Q f'c bad \2 + bo) f'C bo = 2(Dx + d) + 2(Dy + d) f3 = max(Dx, Dy)/min(Dx, Dy) OK Lane Deck 512812021 PROJECT 2.5'x2.5' Footing DATE PROD. # ECR DESIGN a d Pr uz 0 U) Z SHEET