Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED FIR PLN RESUB 1-BLD2023-1110+Architectural_Plan+10.8.2023_12.59.47_PM+3827734
SCOPE OF WORK DRAWING LIST rt► _ � • The Vida ogency ` \ Truss Graphite Ar s Center �y� f � ' / Rick Sues E rope Main St Nails Spa � qiirer • Charcoal P C�as Pantry SanKai ' rde � •'Or Us (s ve90 1 v Corry's Fine Drycleaning 44, ��Salt and ron , rs . Ban of America (wi h • � r �. ' , _ '•; glow In a ro Urive~thru AT ) 7� 1�� 1.ya7� , r ust Pe is n Cafe � o horse Coworking � � .. y�b ea • as =drmo ds The e Naguib o ssef � �. • 'r Ten Ginn Design s y Kimbe I,y J. MacLeod, PC T Tha' Co age �� Studio rominence K•rij�'',.. � :�{ h` i, ,, MOTO Ed o ds •'t � ; Coastal Community Bank P'z a • ' " . }7' Coasta t •�[•• Mail ! Camp Vinfage - s f' ?�►� Antique -store Sunrise Christian � ! cn . . Fellowship • � - � M/ Beauty and The Barbers sea • 1. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. 2. THESE PLANS ARE FOR GENERAL CONSTRUCTION PURPOSES ONLY. THEY ARE NOT EXHAUSTIVELY DETAILED NOR FULLY SPECIFIED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO SELECT, VERIFY, RESOLVE, AND INSTALL ALL MATERIALS AND EQUIPMENT. 3. THE ARCHITECT WILL BE OBSERVING THE CONSTRUCTION FOR COMPLIANCE WITH DESIGN INTENT. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS, AND COMPLIANCE WITH CONSTRUCTION STANDARDS. 4. ALL ACCESSIBILITY DESIGN SHALL BE IN COMPLIANCE WITH IBC CHAPTER 11 AND ICC ANSI A117.1-2009. 5. OCCUPANCY LOAD POSTED VISIBLY NEAR MAIN ENTRANCE/EXIT. 6. SAFETY GLAZING TO BE USED IN DOORS & WINDOWS AT HAZARDOUS LOCATIONS PER IBC 2406.4. 8. PROJECT TO COMPLY WITH THE 2018 INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS AS I E . 9. ANY EXISTING EXTERIOR WALLS OPENED UP DURING CONSTRUCTION TO BE INSULATED WITH A MIN. R-3/ INCH RATING IN ACCORDANCE WITH C101.4.3 EXCEPTION #3. 10. IF REQUIRED, EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA72. 11. COORDINATE ALL MECHANICAL DESIGN WITH ARCHITECT. 12. LIGHT LOCATIONS TO BE PER ARCHITECTURAL LIGHTING PLAN. 13. PRIOR TO MEP CONSTRUCTION, COORDINATE ROOM LAYOUT, REQUIREMENTS AND MOUNTING LOCATIONS; AND PROVIDE A WALK THROUGH WITH OWNER AND ARCHITECT PRIOR TO ELECTRICAL, PLUMBING AND MECHANICAL ROUGH IN. 14. COORDINATE WORK WITH THAT OF OTHER TRADES (MECHANICAL, ELECTRICAL, STRUCTURAL, CIVILAND LANDSCAPE). CONTACT ARCHITECT OF ANY DISCREPANCIES. 15. ALL CONDUIT, PIPES, DUCT WORK, ETC. SHALL BE INSTALLED IN WALLS WHERE POSSIBLE. 16. CONFIRM SPRINKLER HEAD LOCATIONS AND ADJUST AS NECESSARY TO FOR COMPLIANCE WITH PROPOSED PLAN. 17. ADD AND MODIFY FIRE ALARM SYSTEM AS REQUIRED PER THE PROPOSED TENANT IMPROVEMENT PLAN. 18. CONTRACTOR TO COORDINATE W/OWNER ON OWNER PROVIDED ITEMS TO SALVAGEAND STORE FOR REUSE. 19. ENERGY CODE - NO CHANGE TO EXTERIOR 20. SHOP DRAWINGS REQUIRED FOR THE FOLLOWING: - CABINETS, SHELVING - DOORS: FRAMES, HARDWARE - GLAZING - ACOUSTICAL CEILING - FLOORING - PAINT - FINISH MATERIALS: TILE, UPHOLSTERY, WOOD - COUNTERTOPS - FIRE ALARMS - SPRINKLERS - PLUMBING FIXTURES: FLOOR DRAINS, FLOOR SINKS, HOODS - HVAC: DUCTING, FANS, SUPPLY/AIR GRILLS - ELECTRICAL: SWITCHES, LIGHTING, OUTLETS - INSULATION DEFERRED SUBMITTALS MEP DRAWINGS AND SUPPORTING DOCUMENTATION SHALL BE FORMALLY SUBMITTED FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION 2. EXISTING HOOD AND SUPPRESSION SYSTEM SHALL BE CURRENT REGARDING SEMI-ANNUAL CONFIDENCE TESTING AND HOOD/ DUCT CLEANING. THE SEMI-ANNUAL CONFIDENCE TEST AND CLEANING REPORTS SHALL BE SUBMITTED TO "THE COMPLIANCE ENGINE" BY A CERTIFIED CONTRACTOR CONFIRMING THAT THE HOOD AND SUPPRESSION SYSTEM IS UL300 COMPLIANT, CONFIDENCE TESTED, INSPECTED, CLEANED AND CONTAIN NO DEFICIENCIES. ALL WORK MUST BE PERFORMED BY A CERTIFIED KITCHEN HOOD SERVICE CONTRACTOR. CURRENTLY THE EXISTING HOOD AND SUPPRESSION SYSTEMS ARE 464 DAYS OVERDUE. ANY CHANGES TO THE EXISTING APPLIANCE LINE MAY REQUIRE MODIFICATIONS TO THE SYSTEM BY A CERTIFIED CONTRACTOR. ANY REPLACEMENT OR NEW SUPPRESSION SYSTEMS AND/OR HOODS REQUIRE SEPARATE SUPPRESSION AND MECHANICAL PERMITS TENANT IMPROVEMENT TO EXISTING RESTAURANT. UPDATE FRONT OF HOUSE WITH NEW FLOORING, PAINT AND MODIFY EXISTING COUNTERS. IN BACK OF HOUSE REMOVE EXISTING BURNER, FRYER AND GRILL. REPLACE WITH NEW RANGES PER PLAN. PARCEL NUMBER 00434401600503 LEGAL DESCRIPTION EDMONDS PLAT OF BLK 016 D-03 BEG NW COR LT 6 TH ELY ALG GEORGE ST40FT 5 1/2 IN TH SLYAT R ANG 120FT TH WLY ON S LN LT 5 40 FT 5 1/2 IN TO ALLEY TH NLY 120FT TPB BLK C PROJECT ADDRESS ZONING OCCUPANCY BUILDING TYPE BUILDING CODE ENERGY CODE FIRE CODE ENERGY COMPLIANCE GROSS FLOOR AREA MAIN LEVEL OCCUPANTLOAD BUSINESS OWNER SEE CHART AO. 11 SUZETTE JARDING APPROVED 1215 PINE ST SEATTLE, WA 98101 ARCHITECT PLANS MUST STRATAARCHITECTS PLLC 7055 AVE ON JOB SITE SEATTLETLE,, WA, 9818115 CONTACT: AMOREENA MILLER PH: 206-457-5657 MILLER@ STRATAARCH ITECTS.COM APPROVED BY PLANNING Oct 23 2023 Approved DFM ohris P Rrt South County Fire Date: 10/25/2023 10-25-2023 APPROVED WITH CONDITION 1. ADDRESS SIGN MAY NEED TO BE INSTALLED OR IMPROVED FOR VISIBILITY. 2. PREVIOUS HOOD AND SUPPRESSION SYSTEM CONDITIONS APPLY AS NOTED ON PLANS. DFM BURT REFUSE STORAGE WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE 316 MAIN ST 581 EATING PLACES A-2 DINING ESTABLISHMENT VA IBC 2018 W/ WAAMENDS WA 2018 IFC 2018 PERSCRIPTIVE EXISTING PROPOSED 2802 SF EXISTING 76 NO CHANGE PROPOSED 92 A0.00 COVERSHEET AND PROJECT INFO A0.11 LIFE SAFETY PLAN A0.20 EXISTING PLANS + ELEVATIONS A0.30 DEMO PLAN + ELEVATIONS A0.40 EXISTING RCP A2.00 LEGEND, NOTES A2.20 MAIN LEVEL FLOOR PLAN A2.21 EQUIPMENT PLAN A3.20 RCP MAIN FLOOR A3.30 LIGHTING CALCULATIONS A8.00 SCHEDULES A8.10 INTERIOR ELEVATIONS A9.10 INTERIOR BUILDING DETAILS Separate permits for plumbing, mechanical, fire alarm and suppression shall be applied for via MyBuilingPermit.com City Of Edmonds Building Department ---------------------- Work NEW TI-REMODEL Address 316 MAIN ST ----------------------------------------------- Owner MACHIAVELLI Approved Date 10/17/2023 Building Official Eric Permit Number BLD2023-1110 ----------------- " of Edmonds Map Title ff #10) ' 1 • Legend 4 ArcSDE.GIS.STREET-CENTERLINE: . ~ its �• ,�L�,s - <all other values> �. t ` + 5; 4 y, Y 9;71;7;8 Sections Boundary ' f Edmonds Boundary ` ArcSDE.GIS.PROPERTY_BUILDIN( •► ArcSDE.GIS.STREET_CENTERLINE; - <all other values> r Interstate i Principal Arterial Minor Arterial; Collector ' Local Street State Highways r <all other values> #' ,r 0 r 1W 1 2 f • County Boundary f' Parks ArcSDE.GIS.PROPERTY WASHIN( ArcSDE.GIS.PROPERTY-CITIES ArcSDE.GIS.PROPERTY -CITIES 1: 3790- Citv of Edmonds Notes 0 31.57 63.1 Feet 564 47.0 This map is a user generated static output from an Internet mapping site and is for reference only. Data layers that appear on this map may or may not be accurate, WGS_1984_Web _Mercator _Auxiliary _Sphere current, or otherwise reliable. © City of Edmonds THIS MAP IS NOT TO BE USED FOR DESIGN OR CONSTRUCTION 316 MAIN ST OVERHEAD SITE PLAN -_ STRATA ARCHITECTS CREATE / COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET CONSTRUCTION TYPE: __ VA OCCUPANCY GROUP ;_A2 _________- ------------- OCCUPANTLOAD :--------------- 92 MACH IAVELLI 316 MAIN ST EDMONDS WA 98020 D RAW N BY: XXX CHECKED BY: XXX REV: PERMIT RESPONSE DATE: 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 881 ERED CT A MILLER S TE F WASHINGTON SHEET TITLE: COVERSHEET AND PROJECT INFO PROJECT NO. 23013 AO.00 PROJECT DATE: 09/21 /2023 NOTES: 1. Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80%. 2. EXISTING LIGHTING TO REMAIN AND NO CHANGE TO BACK OF HOUSE LIGHTING. 3.Where new wiring is installed to serve new interior luminaires and /or luminaires are relocated to a new circuit; indicate manual and automatic lighting controls are provided (as applicable) - manual (C405.2.3); occupancy sensor (C405.2.1); light reduction (C405.2.3); daylight responsive (C405.2.4); specific application (C405.2.5); ►1 DOOR HARDWA E: HALL EXISTING PANIC EXIT A: 119 sq ft HARDWARE ITIL 119 A: 17 s RUT U- MEN 111 A: 59 sq ft 29'-2 3/4" OWEN 110 A: 46 sq ft WALK IN 112 A: 127 sq ft Ll� WH —a �— I I I - I I n I DISH[___] 107 A: 125 sq ft 0 0 0 EXIST NI� AF MP II ICE IF I PREP I 109 II —A: I I OFFICE 117 A: 143 sq ft 65-10 13/16" '-8 1 /16" OCCUPANTLOAC ROOM NUMBER USE OCCUPANCY SQ LOAD FACTOR OCCUPAN LOAD DINING A-2 1144 84 101 DINING UNCONCENTRATED 939 15 63 102 +21 BAR AREA CHAIRS ONLY 104 7 15 106 SEATING UNCONCENTRATED 101 15 7 KITCHEN KITCHEN 830 5 103 BAR SERVICE 130 200 1 104 SERVER STATION 136 200 1 108 DISH 125 200 1 108 KITCHEN 216 200 1 109 PREP 223 200 1 1 RESTROOMS ACCESSORY 105 110 WOMEN'S RESTROOM 46 111 MEN'S RESTROOM 59 CIRCULATION ACCESSORY 136 105 HALL 119 UTIL 17 OFFICE B 143 1 117 OFFICE 143 100 1 STORAGE _ 99 1 106 STORAGE 99 200 0 TOTALS 2457 92 Plumbing Calculation OCCUPANTS DINING 92 Divide by 2 46 Divide by 7E 0.6 TOTAL 0.6 1 Per Required 1 Per Provided ADA Seating Calculation DINING ZONE ISEATS 5% OF SEATS I REQUIRED 1PROVIDEC Dining 101 84 4 1 4 4 -A L -A L -A L A 00' 11 _ 6 ACCESS TWO E� ITS -0 0 c� <75' TRAVEL co M DINING 0 ACCESS TWO E� 101 75 TRAVEL A 939 sq ft cY) — — — II SERVICIf :1 F- ® II ® \ ' EXIT I co I � � +21 BAR AREA II A�- -104 sq fl� — — — — — — i - -------- - - - ----- - - - - -- -- 1'- 1 16" 104 A: 150 c 11 Eqft] I I � KITCHEN j j SEATING 108 _ 106 BAR SERVICE A: 216 sq ft A: 10 sq ft 103 A 1 s ft U- RAVE DIST N O EXI '- 73'-10 7/8" 26'- 14'-11 1 /2" 11 1 1 /4" DOC HAR EXIT PAN HAR WARE: ING M WARE i STRATA ARCHITECTS CREATE // COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA 98020 D RAW N BY: XXX CHECKED BY: XXX REV: PERMIT RESPONSE DATE: 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE: LIFE SAFETY PLAN PROJECT NO. 23013 AO.1 1 EXITING PLAN AND OCCUPANCY DATE: 09/21 /2023 1 /4" = 1'-0" 0 0" 4'-0" NOTES: 1. Verify that no 20 ; single switch or autc beyond 80%. 2. EXISTING LIGHT CHANGE TO BACK 3.Where new wiring interior luminaires a relocated to a new c automatic lighting cc applicable) - manua sensor (C405.2.1); I daylight responsive application (C405.2 I_ STRATA ARCHITECTS CREATE // COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA 98020 D RAW N BY: XXX CHECKED BY: XXX REV: PERMIT RESPONSE DATE: 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT XFWASHMIINLGTON ERED CT LER SHEET TITLE: EXISTING PLANS + ELEVATIONS PROJECT NO. 23013 AO.20 EXISTING MAIN PLAN 1 /4" = 1'-0" 00��� 0 DATE: 09/21 /2023 0" 4'-0" DEMO NOTES 1. 2. NOTES: 1. Verify that no 20 ; single switch or autc beyond 80%. 2. EXISTING LIGHT CHANGE TO BACK 3.Where new wiring interior luminaires a relocated to a new c automatic lighting cc applicable) - manua sensor (C405.2.1); I daylight responsive application (C405.2 REMOVE EXTERIOR WALK -OFF MAT TO BE REPLACED ilmilm= STRATA ARCHITECTS CREATE // COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA 98020 D RAW N BY: XXX CHECKED BY: XXX REV: PERMIT RESPONSE DATE: 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT • � • c •6 1' 1 . SHEET TITLE: DEMO PLAN + ELEVATIONS PROJECT NO. 23013 AO-30 MAIN DEMOLITION PLAN 1 /4" = 1'-0" DATE: 09/21 /2023 0" 4'-01 rcuit controlled by a control is loaded •O REMAIN AND NO OUSE LIGHTING. :ailed to serve new luminaires are indicate manual and are provided (as 5.2.3); occupancy duction (C405.2.3); .2.4); specific // I_ STRATA ARCHITECTS CREATE // COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA 98020 D RAW N BY: XXX CHECKED BY: XXX REV: PERMIT RESPONSE DATE: 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT • • ' • IMP •6 1 • 1 . SHEET TITLE: EXISTING RCP PROJECT NO. 23013 AO.40 RCP EXISTING 1 /4" = 1'-0"!� 0 DATE: 09/21 /2023 0" 4'-0" LEGEND EXISTING WALL NEW WALL DEMO WALL OVERHEAD STRUCT. 1 HR RATED WALL 110DOOR/WINDOW SYMBOL FULLYACCESSIBLE PATH OF TRAVEL EMERGENCY LIGHT EMERGENCY LIGHT W/ EXIT SIGN PLAN NOTES F1 R1 WALL, FLOOR, ROOF TYPE A D 2 B ELEVATION BUG A5.3 C 1 A5.0 3 SLOPE X:12 BUILDING SECTION PLAN DETAIL ROOF SLOPE 1. ALL DIMENSIONS OF NEW WALLS TO FACE OF STUD UNLESS NOTED OTHERWISE (UNO). CONTRACTOR TO VERIFY DIMENSIONS AND REPORT DISCREPANCIES TO ARCHITECT. 2. ALL PARTITIONS TO UNDERSIDE OF STRUCTURE. U.N.O. 3. WALL TYPES ARE DESIGNATED BY A SYMBOL INDICATING WALL CONFIGURATION, INTERIOR PARTITIONS ARE W1, U.N.O. EXTERIOR WALLS ARE W10, U.N.O. SEE SHEET A2.01 FOR WALL, FLOOR, AND ROOF ASSEMBLIES. 4. SEE SHEETA0.00 FOR ENERGY CODE REQUIREMENTS. 5. SEE SHEET A7.10 FOR DOORS AND A7.20 FOR WINDOWS. 6. INSTALL HARDWIRED SMOKE ALARMS WITH BATTERY BACK UP PER PLAN WHEN CEILING OPENED FOR NEW WIRING. 7. INSTALL CARBON MONOXIDE DETECTORS OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM DWELLING UNITS WITHIN WHICH FUEL FIRED APPLIANCES ARE INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES. 8. NOT USED. 9. BLOCKING/BACKING IS REQUIRED ATTHE FOLLOWING LOCATIONS: WALL MOUNTED CABINETS / WALL MOUNTED ACCESSORIES OR EQUIPMENT. / WALL MOUNTED DOOR STOPS / WALL MOUNTED HOLD OPEN DEVICES / CEILING MOUNTED EQUIPMENT / CLOSET ACCESSORIES / WINDOW TREATMENT / PARTITIONSAND ACCESSORIES. 10-12: NOT USED 13. A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH -EFFICACY LAMPS. 14. FACTORY BUILT FIRE PLACE IS TO BE TESTED IN ACCORDANCE WITH WHH UL 127, LISTED AND LABELED, AND INSTALLED TO THE MANUFACTURER'S DIRECTIONS. 15. NOT USED 16. HANDRAIL SHALL COMPLY WITH IRC 311.7.8 AND SHALL BE ATA HEIGHT BETWEEN 34"-381, ABOVE FINISH FLOOR. PROVIDE EXTENSION AT TOP AND BOTTOM OF EACH RISER. HANDRAIL GRASPING DIMENSION 1-1/4" MINIMUM-2" MAXIMUM 17. GUARDRAILS SHALL COMPLY WITH IRC 312 WITH OPEN LIMITATION OF 4" DIAMETER. 18. PER IRC 302.7 ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER -STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. 19. PER WSEC TABLE 402.1.1 ALL WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH A MINIMUM OF R-10 INSULATION. 20. PER IRC SECTIONS N1101.3 DESIGN PROFESSIONAL OR BUILDER SHALL COMPLETE AND POST AN "INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION" WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. 21. STAIRS TO COMPLY WITH IRC 311.7 -MIN. 36" WIDTH -MAX. 7-3/4" RISER HEIGHT AND MIN. 10" TREAD -MIN. 6-8" HEADROOM -MIN. 3'-0" LANDING LENGTH -MAX. 12'-0" VERTICAL RISE -RISERS 30" ABOVE GRADE SHALL NOT ALLOW THE PASSAGE OF A 4" DIAMETER SPHERE. STRATA ARCHITECTS CREATE / COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA •:1 1 D RAW N BY: XXX CHECKED BY: XXX V 0LVA PERMIT RESPONSE Iby-Al 12I 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT XFWASHMIINLGTON ERED CT LER SHEET TITLE: LEGEND, NOTES PROJECT NO. 23013 A2.00 DATE: 09/21 /2023 LEGEND EXISTING WALL NEW WALL DEMO WALL OVERHEAD STRUCT. /////777 1 HR RATED WALL OOR/WINDOW SYMBO - FULLYACCESSIBLE PATH OF TRAVEL EMERGENCY LIGHT EMERGENCY LIGHT W/ EXIT SIGN RCP LEGEND OP1 r-1 D`) �� SECOND MEANS OF EGRESS NOT REQUIR BE ACCESSIBLE IN EXISTING BUILDING NOTES: 1. Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80%. 2. EXISTING LIGHTING TO REMAIN AND NO CHANGE TO BACK OF HOUSE LIGHTING. 3.Where new wiring is installed to serve new interior luminaires and /or luminaires are relocated to a new circuit; indicate manual and automatic lighting controls are provided (as applicable) - manual (C405.2.3); occupancy sensor (C405.2.1); light reduction (C405.2.3); daylight responsive (C405.2.4); specific application (C405.2.5); TIL 119 A: 17 sq_ft WH i TO P EP 2 T[18 \: 99 sq ft LL HALL 105 A: 119 sq ft MEN 111 A: 59 sq ft 29'-2 3/4" OWEN 110 A: 46 sq ft A 3 SE-E A8.10 FOR ADA UPGRADE WALK IN 112 A: 127 sq ft I -ao- SPLASH GUARD, TYP.---/ I FE --——— — — — — —— e DISHL-j 107 A: 125 sq ft 0 0 0 MOMMON� OWWAS OWWAS� kA:2P sqJt 1 KITCHEN 108 _ A: 216 sq ft ICE II II I I II II II II II II I I LL OFFICE 117 A: 143 sq ft SEATING 106 A: 101 sq ft 73'-10 7/8" SEE A8.00 FOR UPDATED INTERIOR FINISHES. SCOPE OR WORK TO INCLUDE REFINISHING EXISTING HARDWOOD FLOORS, NEW COUNTER TOPS AND PAINT ON INTERIOR WALLS AND CEILING OF THE DINING AREA 65'-10 7/8" I =L 00 J I- FULLYACCESSIBLE `1 PATH OF TRAVEL M — -....- — , STAGE ALBRASS SS O JIAGE GD LO RAIL ' L — — J DINING 00 EXTEND WALL -4" TO FIT BRASS RAIL, V.I.F. co c� '1� - V1 SERVICII 104 A: 150 q ft +21 BAR AREA 102 --A�--104sgft -- - - - -- - - - - - - - - SEE A8.10 FOR BACK BAR REVISIONS 26-9 3/4" rl- - - I II II II II II I� II ao IUD MAIN ENTRANCE FULLY CCESSIBL PATH OF TRAVEL II II -- /--42" H FIXED COUNTER, TB-1 16-9 1 /4" 11MILM STRATA ARCHITECTS CREATE // COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA 98020 D RAW N BY: XXX CHECKED BY: XXX REV: PERMIT RESPONSE DATE: 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE: MAIN LEVEL FLOOR PLAN PROJECT NO. 23013 A2020 MAIN FLOOR PLAN 1 /4" = 1'-0" 0" 4'-0DATE: 09/21 /2023 " // NOTES: 1. Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80%. 2. EXISTING LIGHTING TO REMAIN AND NO CHANGE TO BACK OF HOUSE LIGHTING. 3.Where new wiring is installed to serve new interior luminaires and /or luminaires are relocated to a new circuit; indicate manual and automatic lighting controls are provided (as applicable) - manual (C405.2.3), occupancy sensor (C405.2.1); light reduction (C405.2.3); daylight responsive (C405.2.4); specific application (C405.2.5); ITIL 119 A: 17 SHELVES P EP 2 TF118 V 99 sq ft LL 0 �K10� !K_Ojl EQUIPMENT SCHEDULE ITEM NO QTY MANUFACTURER JW W m O� z Wo �0 d W OQ w v) a x CO) F O W fn x a H U W c _j a Q w z w a � _jz w- w a� 9Z �" ON cn w a �� �: Qz 0 �. V OILLL ON a x cn Q QZ �- Oa O� x C9 x a og ��. U w �N o m a o �Z U- �LU LL c z_ 9-.. pZ � _- �N z m z_ 9 GZ W- �� z ? W N x cn D a m c7 M z L U. Q a O REMARKS B01 1 ESPRESSO 2 GROUP ESPRESSO MACHINE 50 6.1 240 1 X L6-50P 24 3/8 5/8 B02 1 BEVERAGE AIR BB48Y BACK BAR FRIDGE W/ TAPS 5 0.25 115 1 X 6 EXISTING B04 1 KEGWORKS BKHS-W-SS-P WALL MOUNT HAND SINK 0.5 31 0.5 31 1.5 20 EXISTING B05 1 BEVERAGE AIR UC60RA UNDERCOUNTER FRIDGE 5 0.25 115 1 X 6 EXISTING B06 EXISTING B07 1 PERLICK PKD24A GLASS WASHER 12 0.75 110 1 X 8.5 0.5 26.4 1.5 1.5 24 EXISTING B08 1 KROWNE METAL KR-18-36 COCKTAIL BIN 0.5 31.5 0.5 31.5 1.5 20 EXISTING B09 2 DUMP SINK tAlb I GNU K01 1 FLATTOP EXISTING K02 2 VULCAN GAS RANGE NEW K03 2 GAS CONVECTION OVEN EXISTING K04 2 WALL MOUNT HAND SINK 0.5 31 0.5 31 1.5 20 EXISTING K05 1 STAND UP FREEZER 1 0.5 31 0.5 31 1.5 20 1EXISTING K06 3 70" WORK TOP REFRIGERATOR 0.5 31 0.5 31 EXISTING K07 1 45" WORK TOP REFRIGERATOR EXISTING K08 1 TURBO -AIR TSA-1-14-R2 PREP SINK EXISTING K09 1 TURBO -AIR TSA-1-14-L PREP SINK EXISTING K10 MEAT SLICER EXISTING K11 1 DISHWASHER 12 0.75 110 1 X 8.5 0.5 26.4 1.5 1.5 24 EXISTING K12 1 BLENDER EXISTING K13 1 SPRAYER AND SINK EXISTING K14 1 45" UC REFRIGERATOR EXISTING K15 1 MICROWAVE EXISTING K16 1 COLD TABLE EXISTING K17 1 3 COMPARTMENT SINK EXISTING K18 1 24"X24" MOP SINK EXISTING K19 1 SCOTSMAN CU2026MA-1A ICE MACHINE 9.7 115 1 X 6 0.5 30 0.5 8 EXISTING K20 1 TX 14' WALK IN COOLER EXISTING K21 1 HOT WATER TANK EXISTING K22 1 EXISTING 12' HOOD EXISTING K23 1 GREASE INTERCEPTOR EXISTING HALL 105 A: 119 sq ft MEN 111 A: 59 sq ft MMEN 110 A: 46 sq ft WALK IN 112 A: 127 sq ft MWH aa= K04 K18 K09 K08 PREP 109 I I : I TABLE, TYP. I I FE - - - - - - PICK UP SHELF DW TABLE, TYP. K11 e K13 DISH 107 A: 125 s ft q I K02 K17 O O O K16 K06 KITCHEN K22 108 A: 216 so ft II Y I I II � I I Y ILL OFFICE 117 A: 143 sq ft SEATING 106 A: 101 sq ft 73'-10 7/8" CO' N co 00 co d- c� K09 SERVIC 104 A: 150 q ft +21 BAR AREA 102 lam! 1• :1: 1 -1� • 14'-11 1 /2" N LexeyrdFA 1'-0 1 A16" DINING 16-9 1 /4" ® It 11=LM STRATA ARCHITECTS CREATE / COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA 98020 D RAW N BY: XXX CHECKED BY: XXX REV: PERMIT RESPONSE DATE: 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 881 ERED CT A MILLER S TE F WASHINGTON SHEET TITLE: EQUIPMENT PLAN PROJECT NO. 23013 A2.21 EQUIPMENT PLAN 1 /4" = 1'-0" DATE: 09/21 /2023 0" 4'-0" LEGEND EXISTING WALL NEW WALL DEMO WALL OVERHEAD STRUCT. 1 HR RATED WALL DOOR/WINDOW SYMBOL FULLYACCESSIBLE PATH OF TRAVEL EMERGENCY LIGHT EMERGENCY LIGHT W/ EXIT SIGN RCP LEGEND OP1 O P2 — — — UC1 o (E) TRACK HEAD CEILING FAN LIGHTING SCHEDULE SYMBOL DESCRIPTION MANUF. STYLE COLOR MODEL # DIMMING PROVIDED BY OWNER HEIGHT A.F.F. NOTES P1 PENDANT REJUVENATION EASTMORELAND 8" FITTER PENDANT 16" SHADE OPAL SHADE / OLD BRASS 4122130 YES NO SEE A8 CONTRACTOR PROVIDED AND INSTALLED, VERIFY HEIGHT IN FIELD P2 PENDANT GUILD MANOR AMERICAN VINTAGE STRIPE GLASS PENDANT TRANSPARENT TORILL YES NO SEE A8 CONTRACTOR PROVIDED AND INSTALLED INSTALLED, VERIFY HEIGHT IN FIELD UC1 LED TAPE LIGHT WAC LIGHTING INVISILED PRO 2 2700K LED-TX24 YES NO VARIES LEVITON DECORA DIGITAL TIMER SWITCH VPT24-1P EXIT EMERG. LIGHT/EXIT SIGN LITHONIA LIGHTING RED/GREEN LED EXIT/UNIT COMBO, ROUND LAMP RED/GREEN ECRG RD M6 NO NO VARIES EM LT IEMERGENCY LIGHT ILITHONIA LIGHTING IAIMABLE OPTICS IWHITE IELM2L INO I NO I VARIES FAN ICEILING FAN IPRESTO COLLECTION 1HUNTER PRESTO 52" CEILING FAN IBLACK 150810 N/A I NO VIF NOTES: 1. ELECTRICAL PERMIT BY CONTRACTOR. INSTALL TO MEET ALL LOCAL AND STATE BUILDING CODES. 2. SEE PLAN FOR DIMMABLE LIGHT FIXTURES. CONFIRM DIMMER WORKS WITH SPECIFIED LIGHT FIXTURE. 3. ALTERNATES TO BE APPROVED BY OWNER. 4. ALL SWITCHES TO BE LUTRON DIVA GENERAL PUPOSE SWITCH FOR NON DIMMABLE CIRCUITS. DIMMABLE TO BE LUTRON DIVA DIMMABLE. WHITE MATTE 5. SCHEDULE FINAL WALK THROUGH WITH OWNER AND ARCHITECT PRIOR TO ROUGH IN 6. OUTLETS TO BE LUTRON DECORA WHITE OR SIM. 7. PROVIDE OUTLETS AS REQUIRED PER CURRENT CODES. OUTLETS SHOWN ARE ADDITIONAL PER OWNER. PROVIDE USB OUTLETS PER THE LIGHTING PLAN. 8. CENTER LIGHTS IN SPACE EQUALLY ALL DIRECTIONS UNLESS NOTED OTHERWISE. 9. ALL NEW INTERIOR LIGHTING, WIRING, MANUAL, OCCUPANCY SENSOR, AND TIMER CONTROLS PER C405.2.1 NOTES: 1. Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80%. 2. EXISTING LIGHTING TO REMAIN AND NO CHANGE TO BACK OF HOUSE LIGHTING. 3.Where new wiring is installed to serve new interior luminaires and /or luminaires are relocated to a new circuit; indicate manual and automatic lighting controls are provided (as applicable) - manual (C405.2.3); occupancy sensor (C405.2.1); light reduction (C405.2.3); daylight responsive (C405.2.4); specific application (C405.2.5); U IL PREP 2 q •: • ' EXISTING LIGHTING TO REMAIN EXISTING DW LIGHTING TO REMAIN DISH 107 A: 125.28 sq ft REFLECTED CEILING PLAN 1 /4" = 1'-0" (E) LIGHTING TO REMAIN, ADD AUTOMATIC OCCUPANNCY SENSOR AND EMERGENCY FIXTURE O A: 118. 3 sq ft MEN W N 111 110 A A: 59.05 sq ft A: 46.09 sq fftt 3 8.1d C WALK IN 112 A: 127.32 sq ft EXISTING LIGHTING TO REMAIN PREP 109 A: 223 sq ft EXISTING LIGHTING TO REMAIN KITCHEN _ 108 _ _ A: 216.39 sq ft II II II I I II II 1 I ION 50% R�OUC- II OP1 TYP. TIMER SWITCH OFFICE 117 A: 143.02 sq dit EXISTING LIGHTING TO REMAIN TIMER SWITCH (E) SWITCH LOCATION, (E) MANUAL CONTROLS REMAIN, ALL RIMERS FOR N CONTROL 2 3E TI 1 6 A 10 .1 sq ft UC1 2' S RVICE 04 I a UC1 A: 149.56 sq ft I I II I TIMER SWITCH O P2 O TYP. UC1 '0 0 BAR SERVICE 103 A: 130.23 sal 50% MANUAL REDUCTION PROVIDED BY DIMMERS 16'-0" 12'-6" REPLACE (3) CEILING FANS PER LIGHTING SCHED. AIC\AI -rMAnv Cl11-1 /O\ Mol sq (E) TRACK TO REMAIN ■ AREA AP-1 0 C 2X4TYP. NEW ACOUSTIC PANELS THROUGHOUT @° AAF/ 3.10 C UC1�------------- TIMER SWITCH (E) TRACK & HEADS TO REMAIN P1 TYP. It STRATA ARCH I T E C T S CREATE // COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA 98020 D RAW N BY: XXX CHECKED BY: XXX REV: DATE: PERMIT RESPONSE 10/4/2023 PERMIT NO. RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 881 ERED CT A MILLER TE F WASHINGTON SHEET TITLE: RCP MAIN FLOOR PROJECT NO. 23013 A 3 2 0 ■ MDATE: 09/21 /2023 0" 4'-0m6iiiiiii" 10/8/23, 12:42 PM waenergycodes.com/print_ project_summary_form.php?k=Y29tcGxpYW5jZV9tZXRob2Q9c3BhY2VfYnlfc3BhY2UmY29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llN... LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserved Project & Applicant Information Project Title Machiavelli - 2018 WSEC For Building Department Use: I Date' Oct 08, 2023 Project Address 316 Main St Edmonds, WA 98020 Applicant Name Amoreena Miller Applicant Phone 206-779-5316 Applicant Email miller@strataarchitects.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type I I Dining, Restaurant/Bar I Building Cond. Floor Area 2,433 General Project Types Alteration New Building or Addition Lighting S g gco a P Alteration Lighting Scope Interior Lighting ro Pject Cond. Floor Area 2,433 Floors Above Grade 1 Compliance Method Compliance Method 1 -General Lighting Project Description Replace existing light fixtures, add some new lighting. Mix of track lighting with pendants and individual ceiling mount fixtures. LED tape used for accent lighting. Lighting Compliance Scope Project Type Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification and Method Alteration Interior Lighting 50% or more replaced Space by space No Calculation Adjustments allowed COMPLIES Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Ceiling Height (Ft) Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Dining area Bar/lounge/leisure dining 1,532 0.86 1,318 Food preparation 641 1.09 699 Office Enclosed less than 250 sf 134 0.74 99 Restroom General 110 0.63 69 Storage room 50-100 sf 127 0.38 48 Proposed Total LPD 1917 Totals 2,233 1,917 1 COMPLIES Proposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Direct / indirect pendant Pi 20 40 800 Direct / indirect pendant P2 7 40 280 Horizontal surface -mount EXISTING 4 40 160 Troffer EXISTING 11 44 484 Wall -mounted EMERGENCY LIGHTS 10 2 20 Linear Fixtures Low voltage track LED TAPE 35 4 140 Other fixture type EXISTING TRACK 3 11 33 Proposed Total LPD 1917 https://waenergycodes.com/print_ project_summary_form.php?k=Y29tcGxpYW5jZV9tZXRob2Q9c3BhY2VfYnlfc3BhY2UmY29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llNONwZF9hbHR... 112 10/8/23, 12:42 PM waenergycodes.com/print_ project _summary _form. php?k=Y29tcGxpYW5jZV9tZXRob2Q9c3BhY2VfYnlfc3BhY2UmY29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llN... Project Title Machiavelli - 2018 WSEC Date Oct 08, 2023 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (50% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Direct / indirect pendant PI A3.20 LED New Fixture Description: PENDANT Are these fixtures located within a daylight zone?: Yes, applying exception for controls Daylight sensing controls exception applied: Street -level lighting in Group A-2 or M occupancy Do these fixtures require specific application lighting controls?: None required Direct / indirect pendant P2 ROOM 106 TLED I New Fixture Description: PENDANT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Horizontal surface -mount EXISTING 110 AND III Incandescent Existing Fixture Description: Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Supplemental task lighting, occupancy controls Troffer EXISTING 107, 108, 109, 112, 117 AND 118 T-5 Fluorescent Existing Fixture Description: EXISTING Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall -mounted EMERGENCY LIGHTS 1 101, 105, 108, 110, 111, 117, 118 LED New Fixture Description: EMERGENCY BUG LIGHTS Are these fixtures located within a daylight zone?: Yes, applying exception for controls Daylight sensin controls exception applied: Lighting requiring specific application controls g P pP g g q g P pP Do these fixtures require specific application lighting controls?: Exit access & egress lighting per IBC Section 1006.1 Linear Fixtures Low voltage track LED TAPE 102 AND 104 1 LED I New How is linear fixture quantity defined?: Quantity of fixtures with current limiting device Length of track (LT): Fixture Description: Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Display/accent lighting, occupancy controls Other fixture type EXISTING TRACK 103 Halogen Existing How is linear fixture quantity defined?: Quantity of specified luminaires on track section Length of track (LT): 12 Fixture Description: Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required hftps://waenergycodes.com/print_project _summary_form.php?k=Y29tcGxpYW5jZV9tZXRob2Q9c3BhY2VfYn Ifc3 B hY2 U mY29tYm9fdGZ2X3BOP WxOZ 19zY29wZV9uZXdfaW 50ZXJ pb3l l N 0 NwZF9h bH R... 2/2 ! MILM STRATA ARCHITECTS CREATE /COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA •:1 1 D RAW N BY: XXX CHECKED BY: XXX V 0LVA PERMIT RESPONSE Iby—Al 121 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT XFWASHMIINLGTON ERED CT LER SHEET TITLE: LIGHTING CALCULATIONS PROJECT NO. 23013 A330 DATE: 09/21 /2023 FINISH SCHEDULE # ROOM FLOOR BASE WALLS CEILING NOTES Material/Finish Material North East South West Material/Finish 101 DINING FL-5 EXISTING/PT-1 PT-1/PT-2 PT-1/PT-2 PT-1/PT-4 PT-1/PT-2 GWB PT-3/AP-1 102 BAR SEATING FL-5 EXISTING/PT-1 PT-1/PT-2 PT-1/PT-2 PT-1/PT-2 PT-1/PT-2 GWB PT-3/AP-1 EXISTING BAR TOP TO REMAIN 103 BAR SERVICE EXISTING TILE EXISTING/PT-1 PT-1/PT-2 TL-1/MIRROR N/A N/A GWB PT-3/AP-1 EXISTING BACK BAR COUNTERS TO REMAIN 104 SERVICE STATION FL-5 EXISTING/PT-1 PT-1 N/A PT-1/PT-4 N/A GWB PT-3/AP-1 CNT-1 NEW SERVICE STATION COUNTER 105 HALL FL-5 EXISTING/PT-1 PT-1/PT-2 PT-1/PT-2 PT-1/PT-2 PT-1/PT-2 GWB PT-3/AP-1 107 DISH EXISTING TILE EXISTING RB - EXISTING SS EXISTING SS N/A EXISTING PAINT 108 KITCHEN EXISTING TILE EXISTING RB EXISTING PAINT EXISTING PAINT N/A EXISTING PAINT EXISTING PAINT 109 PREP EXISTING TILE EXISTING EXISTING PAINT EXISTING PAINT EXISTING PAINT EXISTING PAINT EXISTING PAINT 110 WOMEN'S RESTROOM FL-1/FL-2 B-2 TL-2/PT-2 TL-2/PT-2 TL-2/PT-2 TL-2/PT-2 GWB PT-3 111 MEN'S RESTROOM FL-1/FL-2 B-2 TL-2/PT-2 TL-2/PT-2 TL-2/PT-2 TL-2/PT-2 GWB PT-3 112 WALK-IN EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING PAINT 117 OFFICE 1EXISTING TILE 1EXISTING PT-2 I PT-2 I PT-2 I PT-2 jGWB PT-3 118 ISTORAGE 1EXISTING TILE 1EXISTING RB 1EXISTING PAINT 1EXISTING PAINT 1EXISTING PAINT 1EXISTING PAINT 1EXISTING PAINT SPECIFICATION SCHEDULE ABBREVIATIONS/FINISHES ITEM BRAND STYLE COLOR FINISH NOTES ACT Acoustic Ceiling Tile AP Acoustic Panel BR Bracket CNT Counter CBHDW Cabinet Hardware EW Engineered Wood FL Flooring FRP Fiberglass Reinforced Panel GT Grout GWB Gypsum Wall Board HW Hardware PLWD Plywood CNT Counter PL Plastic PT Paint RB Rubber Base SS Stainless Steel ST Stain SV Sheet Vinyl TL Tile UP Upholstery z PT-1 SHERWIN WILLIAMS SW 6990 CAVIAR SEMI -GLOSS EXISTING BEADBOARD WAINSCOT AND CASEWORK PT-2 SHERWIN WILLIAMS SW 6379 JERSEY CREAM EGGSHELL GWB WALLS, TYP. PT-3 SHERWIN WILLIAMS SW 6379 JERSEY CREAM FLAT GWB CEILINGS, TYP. PT-4 SHERWIN WILLIAMS SW 6335 FIRED BRICK EGGSHELL ACCENT WALL ST-1 DALYS MATTE NEW WINE RACK/BAR SHELVES TL-1 MUTUAL MATERIALS CRAFTSMAN SLIMBRICK ASHLAND USED N/A RUNNING BOND, BACK BAR WALL TL-2 DALTILE 6X6 SUBWAY TILE ARCTIC WHITE 0190 GLOSSY RUNNING BOND, 48" HIGH FL-1 ROPPE 12X12 RUBBER TILE M188 BRICK INSTALL AT 45 DEGREE ANGLE, ALTERNATING DIAMOND PATTERN W/FL- FL-2 ROPPE 12X12 RUBBER TILE M170 WHITE INSTALL AT 45 DEGREE ANGLE, ALTERNATING DIAMOND PATTERN W/FL-1 FL-3 MATCH EXISTING CERAMIC TILE MATCH EXISTING MATCH EXISTING PATCH AND REPAIR EXISTING TILE FLOOR AS NEEDED FL-4 DMI FLOORS POONA MATTING 92 NATURAL REPLACE EXTERIOR ENTRY WALK -OFF MAT FL-5 EXISTING MAPLE FLOORING REFINISH EXISTING MAPLE FLOORING AND FILL IN AS NEEDED z U CNT-1 WILSONART LAMINATE 1595-38 BLACK FINE VELVET INCL. EDGE BANDING & 4" BACKSPLASH, TYP. b 2 AP-1 ACOUSTICAL SURFACES INC POLY MAX CEILING PANELS 24X48 BEIGE PRE-FAB ATTACH DIRECTLY TO CEILING, CONFIRM SIZE, 24X48 ALSO AVAIL. B-1 N/A WOOD BASE TO MATCH EXISTING PROFILE PT-1 PAINTED INFILL TO MATCH EXISTING BASE AS NEEDED B-2 DALTILE 6X6 SUBWAY TILE COVE BASE A3601 ARCTIC WHITE 0190 GLOSSY COORD. COVE BASE W/TL-2 GT-1 CUSTOM BUILDING PROD GROUT LIGHT, TBD USE WITH SLIMBRICK TL-1 GT-2 CUSTOM BUILDING PROD GROUT DARK, TBD USE WITH SUBWAY TILE TL-2 HW-1 HRL BRASS BISTRO SHELVING SYSTEM BRASS UNLACQUERED CUSTOM 6' LENGTH, SOLD IN SETS OF 2 HW-2 HRL BRASS TIPPING RAIL SYSTEM BRASS UNLACQUERED 24" LENGTHS, VIF HW-3 LITFAD MODERN HANGING WINE GLASS RACK BRASS 1 PIECE 26.2" X 7.1" X 2.4" HW-4 EKENA MILLWORK EMBREY STEEL BRACKET 2" X 8" X 4.25" BLACK POWDER COATED ATTACH SHELVES END TO END ON BRACKETS HW-5 HRL BRASS SHELF BRACKETS #7 BRASS POLISHED UNLAQ. BOTTOM SHELF AT BACK BAR, SEE ELEV. HW-6 HRL BRASS UNLAQUERED BRASS HOOK BRASS POLISHED UNLAQ. ATTACH TO BACK OF RESTROOM DOORS, SEE ELEV. TB-1 BUTCHER BLOCK CO. 1.5" THICK WALNUT BLENDED GRAIN CNT VARNIQUE SEMI -GLOSS REPLACE ALL EXISTING TABLE TOPS, REUSE BASES UP-1 ARCHITEX RYDER BARRISTER BENCH SEATING, 2" FOAM FILL W/ZIP-OFF UPHOLSTERY INTERIOR FINISH NOTES 1. ALL WOOD SURFACES TO BE SEALED, INCLUDING BUT NOT LIMITED TO DOORS, TRIM, SHELVES, CABINETS AND FLOOR. 2. NO EXPOSED PLUMBING OR WIRING. 3. INTERIOR FINISHES TO BE PER THE FINISH SCHEDULE. 4. TRANSITIONS BETWEEN FLOOR MATERIALS TO OCCUR AT CENTER OF DOOR U.N.O. 5. PROVIDE A SMOOTH TRANSITION ATALL FLOOR MATERIALS - CONTRACTOR TO INSTALL ALL FLOOR FINISHES AT THE SAME LEVEL, DESPITE DIFFERENT THICKNESS. PROVIDE FLOOR TRANSITIONS WHERE OCCURS, AND WHERE POSSIBLE. 6. CONTRACTOR TO PROVIDE NECESSARY BLOCKING BEHIND ALL MILLWORK. 7. NO PAINTING OR INTERIOR FINISHING SHALL BE DONE UNDER CONDITIONS WHICH WILL JEOPARDIZE THE QUALITY OR APPEARANCE OF SUCH WORK. 8. ALL SURFACES SHALL BE PREPARED TO RECEIVE THE SPECIFIED FINISH. ALL GYP BOARD PARTITIONS SHALL BE TAPED, SPACKLED AND SANDED SMOOTH. 9. NOT USED 10. UPON COMPLETION, REMOVE ALL PAINT FROM WHERE IT HAS SPILLED, SPLASHED OR SPLATTERED ON EXPOSED SURFACES. 11. PROVIDE OWNER WITH MINIMUM OF 2 FINISH SAMPLES FOR APPROVAL AT LEAST 2 WEEKS PRIOR TO SITE APPLICATION. ON SITE APPLICATION/MOCK-UP WILL BE REQUIRED ONE WEEK PRIOR TO FINAL APPROVAL. 12. ALL EXPOSED PIPING, DUCTWORK, GRILLES, DOOR FRAMES, TO BE PAINTED TO MATCH ADJACENT SURFACE U.N.O. 13. DRYWALL TO BE FINISH LEVEL 4, TYP. ! =,Lam STRATA ARCHITECTS CREATE /COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA •:1 1 D RAW N BY: XXX CHECKED BY: XXX :1031 PERMIT RESPONSE Iby-Al 121 10/4/2023 I PERMIT NO. I RESUB CONTRASTING COLOR, Oct 09 2023 ONDS BLACK 9"X6" CITY M E T SERVICES DEVELOPMENT SERVICES MOUNT CENTERED DEPARTMENT ON DOOR 60" MAX. COPY HEIGHT JTEF ERED CONTRASTING SYMBOLS CT A MILLER VSASHINGTON ULINE UNISEX ACCESSIBLE RESTROOM SIGN S-15599BL 48" MIN. COPY HEIGHT BRAILLE TO MEET ADA REQUIREMENTS SHEET TITLE: SCHEDULES PROJECT NO. 23013 A8.00 ADA SIGN DATE: 09/21 /2023 AID Cap IBCV'IZ'ILC)K TM Developed and Disabilities Act INTERNATIONAL BUILDING CODE Patented in the USA PRODUCT DESCRIPTION Privacy indicator lever lock, interior, non -reversible, for either Right or Left opening doors All -in -one lever, lock and indicator Occupancy indicator IN -USE and VACANT Solid zink alloy handle Push-button locking inside lever Opened by pushing the lever down Full length lever handle with 3/8" return • Commercial use -Ships with mounting hardware • Key -Less emergency unlocking mechanism on the outside/indica handle ADA Compliant LL TECHNICAL DATA • Material: Zink Alloy Handles, Stainless Steel Escutcheon • Door Thickness: Standard Doors 1-3/8" to 2" Adjustable Backset: Standard 2-3/8" and 2-3/4" Dichromate finish for rust resistance ADA DOOR HDWR C5F 1' = V-0" E SERVICE STATION SAFETY Can withstand 2 strikes of 75 pounds of force (90 foot-pounds) Tested to withstand 200,000 opening and closing cycles Stainless Steel Escutcheon Outside Emergency unlock -Fully operable with a closed fist or elbow 10'-3" E EQ. HOOK PER FINISH SCHED., CENTER ON DOOR PAINT PER FINISH SCHE PROVIDE NEW DOC HARDWARE, SEE DETAIL A8. TILE PER FINISH SCHE COVE BASE PE FINISH SCHE 4X4 POSTS, PAINTED PER FINISH SCHEDULE 1X10 WOOD SHELVES, STAINED PER FINISH SCHED. BRACKETS PER FINISH SCHED. J. IR 8/ 10 \ \ D. \ \ R \\ D. \ \ Z.o / A ELEVATION RESTROOM, TYP. 1 /2" = V-0" TIPPING RAIL PER FINISH SCHED. GLASS RACK PER FINISH SCHED. BOTTOM LEVEL ONLY JISH SCHED. REMOVE (E) EQUIP. AND CASEWORK BELOW THIS AREA ONLY I PAINTED PEF C ELEVATION 1'-5" I '�I_nfl ADJUST TOILET LOCATION TO MEET CURRENT ADA CODE Z_ >< �a, c D ELEVATION RRASS ';HFI \/INr, SYRTFkA ELEVATION C "\ VV%I%IL.1` "' '"' PER FINISH SCHEDULE PER FINISH SCHEDULE BACK BAR 011 2'-011 z 00 I_ STRATA ARCHITECTS CREATE // COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA 98020 D RAW N BY: XXX CHECKED BY: XXX REV: PERMIT RESPONSE DATE: 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE: INTERIOR ELEVATIONS PROJECT NO. 23013 A801 0 1 /2" = V-0" 1 /2" = V-0" DATE: 09/21 /2023 (E) WALL GLASS SHELVING PER FINISH SCHEDULE BRASS SHELVING SYSTEM PER FINISH SCHEDULE, ATTACH TO VERTICAL TRIM AND SHELF BELOW 2X4 TRIM, PAINTED PER FINISH SCHEDULE MIRROR 2X WOOD SHELF, STAIN PER FINISH SCHEDULE BRASS BRACKET PER FINISH SCHEDULE (E) COUNTER ri STRATA ARCHITECTS CREATE / COLLABORATE 7055 16TH AVE NE SEATTLE, WA 98115 206.457.5657 COPYRIGHT STRATA ARCHITECTS 2022 CONSTRUCTION SET MACHIAVELLI 316 MAIN ST EDMONDS WA 98020 D RAW N BY: XXX CHECKED BY: XXX REV: PERMIT RESPONSE DATE: 10/4/2023 I PERMIT NO. I RESUB Oct 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEET TITLE: INTERIOR BUILDING DETAILS PROJECT NO. 23013 A9.1 0 1)BA BAR DETAIL 1 1/2"= 1'-0" 0 Im DATE: 09/21 /2023