REVIEWED RESUB 1-BLD2023-1110+Interior_Lighting_Summary+10.8.2023_12.59.47_PM+382773110/8/23, 12:42 PM waenergycodes.com/print_ project_summary_form.php?k=Y29tcGxpYW5jZV9tZXRob2Q9c3BhY2VfYnlfc3BhY2UmY29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3ilN... IGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: ©2023 NEEA, All rights reserved Project Title Machiavelli - 2018 WSEC For Buildin2 De artment Use: I Date' Oct 08, 2023 Project Address 316Main St Edmonds, WA 98020 Project & Applicant REVIEWED RESUB Applicant Name Amoreena Miller Information BY Oct 092023 gLD2023-1110 Applicant Phone 206-779-5316 CITY OF E D M O N DS DEVELOPMENT SERDV CES DEPARTMENT Applicant Email miller@strataarchitects.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Dining, Restaurant/Bar Building Cond. Floor Area 2,433 General Project Types Alteration New Building or Addition Lighting Scope g g P Alteration Lighting Scope Interior Lighting Project Cond. Floor Area 2,433 Floors Above Grade 1 Compliance Method Compliance Method 1 -General Lighting Project Description Replace existing light fixtures, add some new lighting. Mix of track lighting with pendants and individual ceiling mount fixtures. LED tape used for accent lighting. Lighting Compliance Sco a g g P P Project a I TyP Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope P P Compliance Method P LPA Calculation Adjustment Compliance Verification P and Method Alteration I Interior Lighting 1 50% or more replaced I Space by space No Calculation Adjustments allowed I COMPLIES Projec Machiavelli - 2018 WSEC Oct 08, 2 __ Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced, 017Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Ceiling Height (Ft) Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Dining area Bar/lounge/leisure dining 1,532 0.86 1,318 Food preparation 641 1.09 699 Office Enclosed less than 250 sf 134 0.74 99 Restroom General 110 0.63 69 Storage room 50-100 sf 127 0.38 48 Proposed Total LPD 1917 Totals 1 2,233 1,917 COMPLIES oposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Direct / indirect pendant PI 20 40 800 Direct / indirect pendant P2 7 40 280 Horizontal surface -mount EXISTING 4 40 160 Troffer EXISTING 11 44 484 Wall -mounted EMERGENCY LIGHTS 10 2 20 Linear Fixtures Low voltage track LED TAPE 35 4 1 140 Other fixture type EXISTING TRACK 3 11 33 Proposed Total LPD 1917 https://waenergycodes.com/print_project _summary_form. php?k=Y29tcGxpYW5jZV9tZXRob2Q9c3BhY2VfYnlfc3BhY2UmY29tYm9fd GZ2X3BO PWxOZ 19zY29wZV9uZXdfaW50ZXJpb3liNONwZF9hbH R... 1 /2 10/8/23, 12:42 PM waenergycodes.com/print_ project_summary_form.php?k=Y29tcGxpYW5jZV9tZXRob2Q9c3BhY2VfYnlfc3BhY2UmY29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llN... Project Title Machiavelli - 2018 WSEC Date Oct 08, 2023 Proposed Fixtures Details ALTERATION - INTERIOR LIGHTING (50% or more replaced) Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Direct / indirect pendant Pi A3.20 LED New Fixture Description: PENDANT Are these fixtures located within a daylight zone?: Yes, applying exception for controls Daylight sensing controls exception applied: Street -level lighting in Group A-2 or M occupancy Do these fixtures require specific application lighting controls?: None required Direct / indirect pendant P2 ROOM 106 LED I New Fixture Description: PENDANT Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Horizontal surface -mount EXISTING 110 AND III Incandescent Existing Fixture Description: Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Supplemental task lighting, occupancy controls Troffer EXISTING 107, 108, 109, 112, 117 AND 118 T-5 Fluorescent Existing Fixture Description: EXISTING Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall -mounted EMERGENCY LIGHTS 1 101, 105, 108, 110, 111, 117, 118 LED New Fixture Description: EMERGENCY BUG LIGHTS Are these fixtures located within a daylight zone?: Yes, applying exception for controls Daylight sensing controls exception applied: Lighting requiring specific application controls g p pp g g q g P pp Do these fixtures require specific application lighting controls?: Exit access & egress lighting per IBC Section 1006.1 Linear Fixtures Low voltage track LED TAPE 102 AND 104 1 LED New How is linear fixture quantity defined?: Quantity of fixtures with current limiting device Length of track (LT): Fixture Description: Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: Display/accent lighting, occupancy controls Other fixture type EXISTING TRACK 103 Halogen Existing How is linear fixture quantity defined?: Quantity of specified luminaires on track section Length of track (LT): 12 Fixture Description: Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required https://waenergycodes.com/print_project _summary_form. php?k=Y29tcGxpYW5jZV9tZXRob2Q9c3BhY2VfYnlfc3BhY2UmY29tYm9fd GZ2X3BO PWxOZ 19zY29wZV9uZXdfaW50ZXJpb3liNONwZF9hbH R... 2/2