APPROVED BLD BLD2023-0985+Plumbing_Plan+8.23.2023_7.05.53_AM+3741626GENERAL PLUMBING NOTES 1. THE FOLLOWING NOTES APPLY TO ALL PLUMBING DRAWINGS. ADDITIONAL PLUMBING NOTES MAY BE INDICATED ON EACH PLUMBING DRAWING. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2. INSTALLATION SHALL COMPLY WITH ALL GOVERNING CODES AND REGULATIONS (LOCAL AND STATE). NOTHING ON THE DRAWINGS OR SPECIFICATIONS SHALL BE CONSTRUED AS ALLOWING DEVIATION FROM THIS REQUIREMENT. IF A CONFLICT SHOULD OCCUR BETWEEN DRAWINGS AND REGULATIONS, THE REGULATIONS SHALL TAKE PRECEDENT AND CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING OF SUCH CONFLICT PRIOR TO PROCEEDING WITH INSTALLATION. 3. INSTALL ALL WASTE LINE CLEANOUTS IN ACCORDANCE WITH CHAPTER SEVEN OF THE UNIFORM PLUMBING CODE: A. 3" WASTE PIPE - 3" CLEANOUT WITH 2.5" PLUG B. 4" WASTE PIPE - 4" CLEANOUT WITH 3.5" PLUG C. 6" WASTE PIPE - 4" CLEANOUT WITH 3.5" PLUG 4. WASTE, VENT AND SUPPLY PIPING SIZES TO INDIVIDUAL PLUMBING FIXTURES SHALL BE AS SHOWN ON PLUMBING FIXTURE SCHEDULES. BELOW GRADE SANITARY WASTE PIPING SIZES SHALL BE AS SHOWN ON PLANS AND FIXTURE SCHEDULES AND SHALL NOT BE LESS THAN 2" DIAMETER. 5. ALL SANITARY SEWER PIPING BELOW SLAB SHALL BE INSTALLED AT A MINIMUM OF 1 /4" PER FT SLOPE UNLESS APPROVAL IS PROVIDED BY THE "ADMINISTRATIVE AUTHORITY" IN WRITING FOR A SHALLOWER SLOPE. IN NO CASES SHALL SEWER PIPING BE INSTALLED AT LESS THAN 1 /8" PER FT SLOPE. IN NO CASES WILL PIPING SMALLER THAN 4" BE INSTALLED AT SLOPES SHALLOWER THAN 1 /4" PER FOOT. PIPING INSTALLED AT 1 /8"/FT SHALL BE RESIZED PER CHAPTER 7 OF THE UNIFORM PLUMBING CODE AND SUPPORTING CALCULATION SUBMITTED TO ENGINEER FOR REVIEW. 6. PROVIDE STOPS PRIOR TO ALL PLUMBING EQUIPMENT. THIS SHALL ALSO INCLUDE PROVIDING INTEGRAL STOPS ON ALL SHOWER AND TUB/SHOWER VALVES (WHETHER SPECIFIED OR NOT). PROVIDE WASTE TRAPS AT ALL DIRECT CONNECTED EQUIPMENT IN ACCORDANCE WITH CODE AND THE SPECIFICATIONS. 7. PROVIDE TRAP PRIMERS AT ALL FLOOR DRAINS UNLESS NOTED OTHERWISE. PROVIDE UNION ON UPSTREAM AND DOWNSTREAM SIDE OF ALL TRAP PRIMERS. TRAP PRIMER BRANCH TAKEOFF SHALL BE FROM TOP OF MAIN DISTRIBUTION PIPE. 8. INSULATE P-TRAPS EXPOSED IN UNHEATED SPACES. 9. SEE ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE ROUGH -IN DIMENSIONS AND OTHER DETAILS. ALSO SEE ARCHITECTURAL DRAWINGS FOR FINISH REQUIREMENTS OF ALL PLUMBING FIXTURES INCLUDING REQUIREMENTS FOR FLUSH LEVER LOCATION AT ADA COMPLIANT TOILETS AND VALVE LOCATIONS OF ADA SHOWERS. REPORT ALL DISCREPANCIES TO ENGINEER PRIOR TO ANY WORK. 10. REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS. LOCATE PLUMBING FIXTURES AT HEIGHTS SHOWN ON ARCHITECTURAL ROOM ELEVATIONS. 11. PLUMBING DRAWINGS SHOW APPROXIMATE LOCATIONS OF PLUMBING FIXTURES. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS. COORDINATE FLOOR DRAINS FOR MECHANICAL SPACES WITH MECHANICAL EQUIPMENT BEING SERVED. 12. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING CONCRETE EQUIPMENT PADS, FLASHING DETAILS, ETC. 13. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL CHARACTERISTICS OF PLUMBING EQUIPMENT (VOLTAGES, ETC.). 14. ELECTRICAL CHARACTERISTICS OF LISTED EQUIPMENT SHALL BE VERIFIED BY CONTRACTOR DURING SUBMITTAL PROCESS. ANY ELECTRICAL CHARACTERISTICS THAT DEVIATE FROM THOSE LISTED SHALL BE IDENTIFIED BY THE CONTRACTOR, SUBMITTED TO THE ENGINEER FOR APPROVAL AND COORDINATED WITH DIVISION 26 ELECTRICAL PRIOR TO INSTALLATION OF EQUIPMENT AS REQUIRED TO PROPERLY SERVE EQUIPMENT. 15. SECURE WATER HEATERS AND STORAGE TANKS AND PLUMBING EQUIPMENT TO STRUCTURE AS REQUIRED BY CODE. REFER TO THE STRUCTURAL DRAWINGS FOR ADDITIONAL SPECIAL REQUIREMENTS RELATED TO THE PLUMBING INSTALLATION. 16. PROVIDE PLUMBING ANCHORAGE AND EXPANSION EVERY 100' PIPE LENGTH PER CODE. 17. ACCESS PANELS ARE REQUIRED AT ALL CONCEALED VALVES AND EQUIPMENT. COORDINATE LOCATION AND SIZE WITH ARCHITECT. 18. STUB OUT TO SITE SERVICES 5' OUTSIDE BUILDING FOUNDATION. PIPE SIZE, FIXTURE UNITS, AREA DRAINED, INVERT ELEVATION, SIZES, AND SQUARE FOOTAGES AS INDICATED. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK. 19. INSULATE HORIZONTAL RAIN WATER LEADER PIPING FROM ROOF DRAIN TO VERTICAL RISER. 20. INSULATE PIPING PER SEC AND PER DIVISION 22 SPECIFICATIONS (WHICHEVER IS GREATER). 21. GENERALLY DUCTWORK PLANNED TO BE TIGHT TO STRUCTURE WITH PIPING BELOW DUCTWORK AND BETWEEN LIGHT FIXTURES. ADJUST AS NECESSARY. 22. PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6" IF RUNNING PARALLEL AND ABOVE CABLE TRAYS, ALLOW 18" TO THE SIDE OF CABLE TRAYS. 23. COORDINATE LOCATIONS OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND SERVICE ACCESS DUE TO EQUIPMENT MAINTENANCE. 24. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE ROUTING ONLY. 25. PROVIDE FABRICATED STEEL MEMBER SUPPORTS AS REQUIRED BY MANUFACTURER'S INSTALLATION INSTRUCTIONS, AS INDICATED ON DRAWINGS, OR IN SPECIFICATIONS FOR INSTALLATION OF EQUIPMENT. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 26. IF REQUIRED FOR INSTALLATION OF PIPES AND EQUIPMENT, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. 27. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS, UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. 28. PIPES INDICATED WITHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM PIPE SECTIONS. 29. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW PIPING OFFSETS WHICH MAY BE REQUIRED. 30. ALL WATER, SOIL, AND WASTE PIPING IN AREAS SUBJECT TO FREEZING SHALL BE PROTECTED FROM FREEZING PER THE REQUIREMENTS OF THE UPC 312.6. 31. WHERE PIPE SIZES ARE NOT SHOWN ON DRAWINGS, SIZE PIPING PER THE UNIFORM PLUMBING CODE. 32. PRIOR TO SUBMITTING ALL PLUMBING FIXTURES THE CONTRACTOR SHALL VERIFY COMPATIBILITY OF THE SPECIFIED FIXTURE WITH THE SIZES OF FINISH CABINETRY AS IDENTIFIED IN GENERAL CONTRACTOR'S SHOP DRAWINGS. ANY DISCREPANCIES BETWEEN THE SIZE OF THE FIXTURES SPECIFIED AND THE FINISH CABINETRY SIZES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING BEFORE SUBMITTAL. 33. PLUMBING VENTS SHALL TERMINATE A MINIMUM 10' FROM OUTSIDE AIR INTAKES, PER CODE. 34. LABEL ALL PIPING SYSTEMS PER THE IMC AND UPC. 35. SUPPORT AND BRACE PIPING SYSTEMS IN ACCORDANCE WITH UPC SECTION 314 AND AS REQUIRED IN THE SPECIFICATIONS. 36. ALL MATERIALS IN CONTACT WITH PIPING SYSTEMS SHALL BE COMPATIBLE FOR USE WITH AND FOR CONTACT WITH THE PIPING MATERIAL. CONTRACTORS AND TRADES SHALL VERIFY COMPATIBILITY OF THEIR PRODUCTS WITH THE PIPING SYSTEMS. THIS INCLUDES, BUT IS NOT LIMITED TO, FIRE STOPPING SEALANTS, FIRE STOPPING COLLARS, VIBRATION ISOLATION ELEMENTS, THERMAL INSULATION, EXPANSION JOINTS AND ANY MATERIAL IN CONTACT WITH PIPES. 37. ALL CAST IRON SOIL PIPE AND FITTINGS SHALL BE MARKED WITH THE COLLECTIVE TRADEMARK OF THE CAST IRON SOIL PIPE INSTITUTE (CISPI) AND BE LISTED BY NSF INTERNATIONAL. 38. PIPE BURIAL METHODS FOR BELOW -GRADE PIPING SHALL COMPLY WITH MFR. INSTALLATION INSTRUCTIONS, ASTM D 2321 AND ASTM F1668. FAILURE TO FOLLOW THESE REQUIREMENTS CAN LEAD TO PIPE FAILURE. 39. ROOF -MOUNTED PIPING SHALL BE INSTALLED ON FREE-FLOATING, PREFABRICATED SUPPORTS SIMILAR TO MIRO MODEL 24-R OR ROOF TOP BLOX ON WALKWAY TREAD PADS. THE USE OF WOOD FOR SUPPORTS IS PROHIBITED. 40. ALL ITEMS IN CONTACT WITH POTABLE WATER SHALL COMPLY WITH THE NATIONAL "REDUCTION OF LEAD IN DRINKING WATER ACT" S.3874. 41. WHERE MANUFACTURERS HAVE RECOMMENDED OR REQUIRED TRAINING PROGRAMS FOR THE INSTALLATION OF THEIR PRODUCT, ALL CONTRACTOR EMPLOYEES INSTALLING THAT PRODUCT SHALL BE TRAINED AND HAVE WRITTEN DOCUMENTATION CONFIRMING THAT TRAINING AND SHALL FURNISH A COPY OF THE TRAINING DOCUMENTATION WITH THE PROJECT SUBMITTAL FOR EACH INSTALLING INDIVIDUAL SHOWING CURRENT INSTALLATION TRAINING WITHIN TWO (2) YEARS OF START OF THE THIS PROJECT. PLUMBING LEGEND SYMBOL DESCRIPTION VALVES BALANCING VALVE PRESSURE REGULATING VALVE PRESSURE REDUCING VALVE (PRV) AUTOMATIC CONTROL VALVE - TWO WAY (ELECTRIC OPERATOR SHOWN) AUTOMATIC CONTROL VALVE - THREE WAY (ELECTRIC OPERATOR SHOWN) i� BALL VALVE GATE VALVE GAS COCK RELIEF VALVE CHECK VALVE I� BUTTERFLY VALVE o- REDUCED PRESSURE BACKFLOW ASSEMBLY BALANCING/MEASURING VALVE REFERENCE CODES IBC INTERNATIONAL BUILDING CODE - 2018 IMC INTERNATIONAL MECHANICAL CODE - 2018 UPC UNIFORM PLUMBING CODE - 2018 IFGC INTERNATIONAL FUEL GAS CODE - 2018 IFC INTERNATIONAL FIRE CODE - 2018 NEC NATIONAL ELECTRICAL CODE - 2020 WSEC WASHINGTON STATE ENERGY CODE - 2018 ICC ICC A117.1 ACCESSIBILITY CODE - 2009 ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS - A17.1 - 2007 W/ 2008 ADDENDA SAFETY CODE FOR ELEVATORS AND ESCALATORS NFPA NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS 13D, 13R, OR 13 (AS APPLICABLE) - 2016 SHEET INDEX SHEET TITLE NO. PO.01 PLUMBING ABBREVIATIONS, NOTES & LEGEND PO.02 PLUMBING SCHEDULES AND CALCULATIONS P1.00 UNDERGROUND PLUMBING PLAN P2.01 LEVEL 1 PLUMBING PLAN P3.00 PLUMBING DETAILS P4.00 PLUMBING RISER DIAGRAMS TABLE C404.3.1 - HOT WATER PIPING VOLUME NOMINAL PIPE SIZE (IN.) VOLUME Z. PER FOOT O LENGTH) MAXIMUM PIPING LENGTH (FT.) PFAUCETSUBLIC V OTHER FIXTURES/APPLIANCES Y" 1.5 2.0 43.0 %" 3.0 0.5 21.0 1" 5.0 0.5 13.0 1Ya" 8.0 0.5 8.0 1Y" 11.0 0.5 6.0 2" AND LARGER 18.0 0.5 4.0 PLUMBING LEGEND SYMBOL DESCRIPTION PIPING FLOW ARROW I� CAP OR CLEANOUT PIPE UP OR TEE UP AND DOWN PIPE DOWN PIPE TEE UP PIPE TEE DOWN 45' DEGREE ELBOW 90' DEGREE ELBOW 4 WAY TEE TEE PIPE BREAK PIPING SPECIALTIES 4 PRESSURE GAGE THERMOMETER SIGHT GLASS VENTURI FLOW METER FLOW METER MANUAL AIR VENT (MAV) GAS PRESSURE REGULATOR M WATER METER y WYE STAINER WYE STAINER WITH CAPPED HOSE END BLOWDOWN VALVE J FLANGE UNION ECCENTRIC REDUCER STEAM TRAP HOSE BIBBS HOSE BIBB/WALL HYDRANT PIPE ANCHOR ALLIGNMENT GUIDE TS t TEMPERATURE/PRESSURE TEST PORT/PETE'S PLUG '-' FLEXIBLE CONNECTION IN PIPING FUNNEL Y PLUMBING LEGEND SYMBOL DESCRIPTION GENERAL NORTH NORTH ARROW A SECTION IDENTIFICATION M201 SHEET IDENTIFICATION SHEET NOTES RISER CALLOUT (RISER-1 PLUMBING FIXTURE TAG (WC-1 REVISION CALLOUT (REV-1 REVISION BUBBLE DETAIL CALLOUT (1 /P2.05) COLUMN GRID SYMBOLS GENERAL MECHANICAL NOTES NUMBER IDENTIFICATION FLAG MECHANICAL NOTES NUMBER IDENTIFICATION EXISTING WORK OR BACKGROUND INFORMATION (LIGHT LINE NEW WORK (HEAVY LINE RELOCATE EXISTING EQUIPMENT ITEM OR DEVICE INDICATED EXISTING EQUIPMENT OR PIPING TO BE SELECTIVELY DEMOLISHED TYPICAL EQUIPMENT DESIGNATION (PUMP) POINT OF CONNECTION TO EXISTING WATER PIPING SYSTEMS W$ WATER SERVICE COLD WATER FILTERED CWF - COLD WATER (ABOVE FLOOR/GRADE) HOT WATER (ABOVE FLOOR/GRADE) (120' F TEMPERED WATER IF NOT INDICATED OTHERWISE) 140 HIGH TEMP HOT WATER 140' OR AS INDICATED 160 HIGH TEMP HOT WATER 160° OR AS INDICATED T TEMPERED WATER TWC TEMPERED WATER CIRCULATING - - - HOT WATER CIRCULATING NP NON POTABLE WATER M WATER METER HEAT TRACE FOR COLD WATER PIPE DRAIN WASTE & VENT PIPING WASTE (ABOVE FLOOR) PIPING - WASTE (BELOW FLOOR) PIPING ---------------- VENT AW ACID WASTE GW GREASE WASTE GD GARAGE DRAIN C CONDENSATE DRAIN P PUMPED PIPING FCO FLOOR CLEANOUT (FCO) WCO WALL CLEANOUT (WCO) Q VTR VENT THRU ROOF ® FLOOR DRAIN ❑o FLOOR SINK REUSE OF DOCUMENTS VERIFY SCALE BAR MEASURES ONE INCH THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS 0 THE PROPERTY OF HV ENGINEERING, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING, ADJUST SCALES COPYRIGHT, HV ENGINEERING, INC. ACCORDINGLY. HV Engineering, Inc. Consulting Engineers Hall Creek Office Park 6912 220th St. SW, Suite 303 Mountlake Terrace, WA 98043 Phone: (206) 706-9669 www.hvengineering. biz Project - Stillhouse Coffee nratinr 558 Main Street Suite 108 Edmonds, WA 98020 Prepared For JD Plumbing & Fire Protection P.O. Box 1770 19495 144th Ave NE, A125 Woodinville, WA 98072 NO. DATE REVISION PARTNER IN CHARGE SDB PROJECT MANAGER PMB PROJECT ENGINEER BAQ PROJECT TEAM MEMBERS NIP, PMB, BAQ CHECK SDB --- --, -�23 TITLE PLUMBING NOTES, ABBREVIATIONS & LEGEND PROJECT NO. 2023-067 DATE AUGUST 22, 2023 91116AX611nwi'yGIVIV is SHEET NUMBER P0001 PLUMBING CALCULATIONS 2018 UPC PLUMBING CODE PER TABLE 702.1 AND TABLE A-103.1 CW/HW FOR RESIDENTIAL FIXT. PER SEPARATE APPENDIX M CALC BUILDING SUMMARY MIN. SIZE TRAP/ARM IN. QTY DOMESTIC WATER WSFU SEWER DFU FIXTURE TYPE PER FIXTURE TOTAL* HW PER FIXTURE TOTAL* HW PER FIXTURE TOTAL FLOOR DRAIN (30-50 GPM) 3 1 0 0 RECEPTOR, INDIRECT WASTE (30<GPM<50) 3 2 6 12 COMMERCIAL KITCHEN AND LAUNDRY EQUIPMENT DISHWASHER - INDIRECT WASTE <50 GPM IW 1 4 4 DIPPER SINK IW 1 2 2 DUMP SINK 2 1 2 2 2 2 2 2 THREE COMP SINK IW 1 3 3 2.25 2.25 -- -- PREP SINK IW 1.5 1.125 2 0 HAND SINK 1.5 1 1 1 1 0.75 1 0.75 1 1 PITCHER RINSER IW 1 1 1 ICE MAKER IW 1 1 1 ESPRESSO MAKER IW 1 1 1 POT FILLER, HOT ONLY 2 _ _ 2 I TOTALS 11 1 13 1 7L 15 TOTAL PEAK BUILDING WATER DEMAND (GPM) 9 1-1/2" EXISTING CW STUB NOTE: 4" WASTE STUB PROVIDED: BASED ON 15 DFUS. A 4" WASTE PIPE AT 1/8" PER FOOT SLOPE CAN HANDLE 172 DFU PER 2018 UPC TABLE 703.2. 2018 UPC WATER SERVICE CALCULATIONS APPENDIX M FOR RESIDENTIAL AND APPENDIX A FOR BALANCE OF BLDG CALCULATE APP. A GPMS Cold Water Piping to be Sized Based on a FT System (FV=Flush Valve, FT = Flush Tank) Hot Water Piping to be Sized Based on a FT System (FV =Flush Valve, FT = Flush Tank) PIPE MAINS FIX UNIT GPM APPENDIX A SUPPLY 13 9 COLD WATER 13 9 HOT WATER 7 6 STATIC WATER PRESSURE (PSI) 78.0 COLD WATER PRESSURE LOSS: ELEVATION CHANGE (PSI) 0 FEET AT 0.433 PSI/FT MIN. RESIDUAL PRESS. AT REMOTE FIXT. (PSI) 30.0 (TYPICALLY PROVIDE 25 PSIG + 5 PSIG FOR TXV) TOTAL PRESSURE LOSS: 30.0 AVAILABLE PRESSURE (PSI) 78.0 - 30.0 48.0 LONGEST PIPE RUN (FT) 50 48.00 X 1.25 (FITTINGS) 1.25 62.5 Size All Piping Based on a Friction loss of: 12 PSI/100FT LOSS and max velocity based on installation standard. DOMESTIC WATER PIPE SIZING TABLE WSFU BASED ON 2018 UPC CHART A103.1(1) PIPE MATERIAL TYPE L COPPER FLUSH TANK VELOCITY <= 8 FPS COLD PSI/100 FT 12 MIN/MAX RANGE MIN MAX PIPE SIZE (") UNITS 1/2 WSFU 0 4 GPM 0 3 3/4 WSFU 4.5 14 GPM 3 10 1 WSFU 15 30 GPM 11 20 11/4 WSFU 31 55 GPM 20 31 11/2 WSFU 56 100 GPM 31 44 2 WSFU 101 265 GPM 44 77 COPYRIGHT HV ENGINEERING PIPE MATERIAL TYPE L COPPER FLUSH TANK VELOCITY <= 5 FPS HOT PSI/100 FT 12 MIN/MAX RANGE MIN MAX PIPE SIZE (") UNITS 1/2 WSFU 0 4 GPM 0 3 3/4 WSFU 5 9 GPM 41 7 1 WSFU 10 16 GPM 7 12 11/4 WSFU 17 28 GPM 12 19 11/2 WSFU 29 45 GPM 19 27 2 WSFU 46 120 GPM 27 48 COPYRIGHT HV ENGINEERING X 100 FT 63 FT DOMESTIC WATER PIPE SIZING TABLE WSFU BASED ON 2018 UPC CHART A103.1(1) PIPE MATERIAL PEX FLUSH TANK VELOCITY <= 8 FPS CW+HW PSI/100 FT 12 MIN/MAX RANGE MIN MAX PIPE SIZE (") UNITS 1/2 WSFU 0 4 GPM 0 3 3/4 WSFU 4 9 GPM 3 7 1 WSFU 10 20 GPM 7 14 11/4 WSFU 21 32 GPM 15 21 11/2 WSFU 33 52 GPM 21 30 2 WSFU 53 130 GPM 30 51 COPYRIGHT HV ENGINEERING KITCHEN PLUMBING EQUIPMENT TABLE [1] v v v +) 41 v � � (6 +' U U Item U No Qty Equipment Category Manufacturer Model Number U cn LN = cn o w v 1 1 ESPRESSO MAKER LAMARZOCCO LINEA PB 3 HEAD 1/2" X 240v 50A X 5 1 DISHWASHER JACKSON DISHSTAR HT 3/4" X 208v 37A X 6 1 DUMP SINK WATERLOO SINK 1/2" 1/2" X X 7 1 DIPPER SINK REGENCY DIPPER WELL/FAUCET 1/2" X X 8 1 PITCHER RINSER RHINO JUG WASHER 1/2" X X 9 1 3-COMP SINK REGENCY UC 3 COMP 1/2" 1/2" X X 10 1 HAND SINK REGENCY WALLMOUNT GOOSE 1/2" 1/2" X X 12 2 FLOOR SINK [2] [2] X X 18 1 ICE MAKER AVANTCO UC-H-280-A 1/2" X 115v 15A X NOTE 1: VERIFY FINAL FIXTURE SELECTIONS WITH KITCHEN CONSULTANT, GC & OWNER PRIOR TO PROCUREMENT. NOTE 2: SEE MISC. PLUMBING SCHEDULE FOR FIXTURE SELECTION PUMPS EQUIPMENT NUMBER CP-1 SERVICE LOCATION CAFE REAR ENTRY SERVICE/ COMMERCIAL KITCHEN SYSTEM DOMESTIC HW TYPE I CIRCULATOR SERVICE CONDITIONS CAPACITY -GPM 1.0 TOTAL HEAD -FT 13.8 FLUID DOMESTIC WATER TEMPERATURE -DEG F 120 MOTOR HORSEPOWER -MINIMUM 1/25 VOLTS -PHASE -HERTZ 115-1-60 CONNECTIONS MANUFACTURER -DESIGN BASIS GRUNDFOS UP1518B5TLC WEIGHT REMARKS [11 IMPELLER DIAMETER OF PUMP SHALL NOT BE GREATER THAN 90% OF THE MAXIMUM POSSIBLE IMPELLER DIAMETER FOR THE PUMP. TANKLESS WATER HEATER SCHEDULE EQUIPMENT NUMBER WH-1 SERVICE CONDITIONS TYPE TANKLESS TEMPERATURE 120 DEGREE STORAGE CAPACITY NA MIN. OPERATING FLOW RATE 0.2 GPM TEMP RISE @ 2.0 GPM 120 DEG F TEMP RISE @ 2.5 GPM 100 DEG F TEMP RISE @ 3.5 GPM 70 DEG F TEMP RISE @ 4.0 GPM 60 DEG F TEMP RISE @ 6.0 GPM 40 DEG F WORKING PRESSURE (PSIG) 150 DIMENSIONS 17-11/16" (W) x 25" (H) x 4-9/16"(D) WEIGHT 39 LBS ELECTRICAL DATA VOLT/HERTZ/PHASE 208/60/3 KILOWATTS (KW) 36 MANUFACTURER -DESIGN BASIS MANUFACTURER/MODEL HUBBEL TX036-6R MISCELLANEOUS PLUMBING EQUIPMENT SCHEDULE SYMBOL ITEM MAKE/MODEL REMARKS DRAINS FS-1 FLOOR SINK ZURN FD2376 SEE DETAIL 9-P3.00 FD-1 FLOOR DRAIN (FD) OR FUNNEL (FFD) (SIZE PER PLANS) PROFLO PF821200ANR SEE DETAIL 4-P3.00. PROVIDE TRAP PRIMER PER DETAIL 5-P3.00 TRAP PRIMERS TP-1 TRAP PRIMER PPP INSTALL WHERE REQUIRED BACKFLOW PREVENTERS BFP-1 3/4" REDUCED PRESSURE ZONE BACKFLOW ASSEMBLY WATTS 009QT DISHWASHER - I.W. TO APPROVED LOCATION, NSF 61 COMPLIANT BFP-2 3/4" REDUCED PRESSURE BACKFLOW ASSEMBLY WATTS 009QT DISHWASHER DRAIN COOLER - I.W. TO APPROVED LOCATION, NSF 61 COMPLIANT BFP-3 1/2" REDUCED PRESSURE BACKFLOW ASSEMBLY WATTS 009QT ESPRESSO MAKER - I.W. TO APPROVED LOCATION, NSF 61 COMPLIANT TEMPERING VALVES TV-1 THERMOSTATIC MIXING VALVE CASH ACME HG135-LF 3/8" MIXING VALVE, ASSE 1070 CERTIFIED. NSF/ANSI 61/372 APPROVED. PIPING SYSTEM SCHEDULE AND SPECIFICATION SYSTEM ABOVE GROUND BELOW GROUND JOINT METHOD REMARKS/PIPE INSULATION SOIL/WASTE/VENT ABS CAST IRON ABS SOLVENT WELD NO HUB COLD WATER & HOT WATER TYPE M COPPER PEX SOLDER JOINTS PEX CONNECTIONS PER MANUFACTURER INSULATE PER WSEC REUSE OF DOCUMENTS VERIFY SCALE BAR MEASURES ONE INCH THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS 0 1 THE PROPERTY OF HV ENGINEERING, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING, ADJUST SCALES COPYRIGHT, HV ENGINEERING, INC. ACCORDINGLY. 1 �w VJ ti J HV Engineering, Inc. Consulting Engineers Hall Creek Office Park 6912 220th St. SW, Suite 303 Mountlake Terrace, WA 98043 Phone: (206) 706-9669 vvvvw.hvengineering. biz Project - Stillhouse Coffee nratinr 558 Main Street Suite 108 Edmonds, WA 98020 Prepared For JD Plumbing & Fire Protection P.O. Box 1770 19495 144th Ave NE, A125 Woodinville, WA 98072 NO. DATE REVISION PARTNER IN CHARGE SDB PROJECT MANAGER PMB PROJECT ENGINEER BAQ PROJECT TEAM MEMBERS NIP, PMB, BAQ CHECK SDB --- --, -�23 TITLE PLUMBING CALCULATIONS PROJECT NO. 2023-067 DATE AUGUST 22, 2023 1:ZialM61ikI:1111',511147Jia SHEET NUMBER P0002 GENERAL NOTES: 1. ALL SANITARY DRAINAGE PIPING SLOPED AT %4"/FT UNLESS OTHERWISE NOTED, SLOPE ALL PIPING AS REQUIRED PER PLUMBING CODE. SHEET NOTES: Oi CONNECT TO EXISTING UTILITY STUB OTRAP ARM LENGTH EXCEEDS UPC TABLE 1002.2 ALLOWANCE. BASED ON KITCHEN CONSULTANT LOCATED FIXTURES, VENT CANNOT ROUTE UP IN MIDDLE OF SPACE AND THEREFORE MUST ROUTE HORIZONTALLY TO WALL DUE TO STRUCTURAL CONDITIONS. SLOPE VENT BACK TO DRAIN LINE & TIE VENT INVERT OFF ABOVE THE CENTERLINE OF THE DRAINAGE PIPE PER UPC 905.3 O z UNDERGROUND PLUMBING PLAN SCALE: %4" = 1'-0" REUSE OF DOCUMENTS VERIFY SCALE BAR MEASURES ONE INCH THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS 0 THE PROPERTY OF HV ENGINEERING, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING, ADJUST SCALES COPYRIGHT, HV ENGINEERING, INC. ACCORDINGLY. ti HV Engineering, Inc. Consulting Engineers Hall Creek Office Park 6912 220th St. SW, Suite 303 Mountlake Terrace, WA 98043 Phone: (206) 706-9669 www.hvengineering. biz Project Stillhouse Coffee nratinr 558 Main Street Suite 108 Edmonds, WA 98020 Prepared For JD Plumbing & Fire Protection P.O. Box 1770 19495 144th Ave NE, A125 Woodinville, WA 98072 NO. DATE REVISION PARTNER IN CHARGE SDB PROJECT MANAGER PMB PROJECT ENGINEER BAQ PROJECT TEAM MEMBERS NIP, PMB, BAQ CHECK SDB I0ZICI►IAA:;WAi1I --- --, -�23 TITLE UNDERGROUND PLUMBING PLAN PROJECT NO. 2023-067 DATE AUGUST 22, 2023 1:Zial:161i�I ifyil:i7Jia SHEET NUMBER Pi ■ GENERAL NOTES: 1. VERIFY FINISHED FLOOR ELEVATION OF CAFE SPACE. MUST BE ABOVE 0" TO MEET INVERT ELEVATION OF WASTE POC. SHEET NOTES: < CONNECT TO EXISTING UTILITY STUB O z LEVEL 1 PLUMBING PLAN SCALE: %4" = 1'-0" REUSE OF DOCUMENTS VERIFY SCALE BAR MEASURES ONE INCH THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS 0 THE PROPERTY OF HV ENGINEERING, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING, ADJUST SCALES COPYRIGHT, HV ENGINEERING, INC. ACCORDINGLY. ti HV Engineering, Inc. Consulting Engineers Hall Creek Office Park 6912 220th St. SW, Suite 303 Mountlake Terrace, WA 98043 Phone: (206) 706-9669 www.hvengineering. biz Project Stillhouse Coffee nratinr 558 Main Street Suite 108 Edmonds, WA 98020 Prepared For JD Plumbing & Fire Protection P.O. Box 1770 19495 144th Ave NE, A125 Woodinville, WA 98072 NO. DATE REVISION PARTNER IN CHARGE SDB PROJECT MANAGER PMB PROJECT ENGINEER BAQ PROJECT TEAM MEMBERS NIP, PMB, BAQ CHECK SDB 1Q1d'1AA:;W:F:11 --- --, -�23 TITLE LEVEL 1 PLUMBING PLAN PROJECT NO. 2023-067 DATE AUGUST 22, 2023 91116AX61i�I ify8I:i7Jia SHEET NUMBER P2001 COUNTER TOP 2"V UP IN WALL PLUMBING FIXTURE CONNECT TO RUN LOOP AS HIGH VENT SYSTEM CW & HW AS POSSIBLE UP TO FAUCET CW & HW BELOW 135° FLOOR, OVER AND UP I WALL TT 2" CLEANOUT C.O. 2" WASTE 1 J�" VENT (SLOPE TO 3" WASTE DRAIN -MINIMUM 2%) ISLAND WASTE AND VENT LOOP DETAIL SCALE: NTS DEPRESS WHERE N FIND FLOOR DRAIN DETAIL SCALE: NTS ALL INSIDE FLUSH CLEANOUTS SHALL BE INSTALLED IN SUCH A MANNER THAT THE TOP COVER SHALL BE FLUSH WITH THE SURFACE OF THE FINISHED FLOOR. INTERIOR CLEANOUT DETAIL SCALE: NTS COVER LOCKING SCREW RIM FRAME ASSEMBLY CLAMPING FLANGE & RING (WHERE REQUIRED) GASKET CO. PLUG KEEP OUTLET PIPE STRAIGHT WITH AT LEAST 1 /4" PER FOOT SLOPE 5' MAX DISCHARGE VIA 2" AIR GAP AS INDIRECT WASTE TO FLOOR SINK 3-COMPARTMENT SINK DETAIL SCALE: NTS MAX 1h"C- ACCESS DOOR (AT RECESSED LOCATION IN FINISHED SPACES) ZE PER PLANS 6"MIN. ABOVE FLOOD )R TO OFFSETTING OR PING TO OTHER VENTS PRESSURE REDUCING VALVE WITH THERMAL EXPANSION BYPASS 3/4"HW INLET FLOOR 1 >12" ABOVE DRAIN FOR 20' OF PRII IL" MMAKVILI UNION TYP. PPP P2-500 PRIME RITE TRAP PRIMER VALVE DISTRIBUTION UNIT DU-4/DU-U WHERE APPLICABLE Jh" COPPER TO FLOOR DRAIN, TRAP MAKE UP WATER (TYP.) QTY. AS REQUIRED (MAX 4) TRAP PRIMER DETAIL SCALE: NTS 2" VENT Up-, I I BFP-1 CO WATER HAMMER ARRESTOR STRAINER W/ BLOW -OFF VALVE THERMOMETER/PRESSURE GAUGE T&P VALVE %"CW TO BFP-2* COMMERCIAL FROM NEAREST CW DISHWASHER SOURCE = WH BFP-2 �EP U * PIPE RELIEF VALVE TO OPEN DRAIN, INSTALL I DISHWASHER DRAIN COOLER IN ACCORDANCE WITH ALL LOCAL CODES. VALVE, THERMOMEGATECH DTV-1/2". PROVIDE WATER 3" WASTE _J HAMMER ARRESTER. FS-1 FLOOR SINK DISHWASHER CONNECTION DETAIL SCALE: NTS OFFSET HOT WATER MAIN TO HAND LAVATORY AS NEEDED. THERMOSTATIC TV TEMPERING VALVE 1 NOTE: ROUTE HOT WATER PIPING MAIN OVER TO HAND SINK SUCH THAT NO MORE THAN 2' OF "DEAD" BRANCH PIPE EXISTS PER WSEC C4033.1. TYPICAL FOR ALL HAND SINKS AND LAVATORIES. TYPICAL LAVATORY / HAND SINK TYPICAL LAVATORY & HAND SINK PIPING DETAIL SCALE: NTS NOT USED SCALE: NTS HALF -GRATE OR NO -GRATE AS INDICATED ON KITCHEN PLANS INSTALL FLUSH WITH FINISHED FLOOR OR AS LOCAL CODES REQUIRE. SOME LOCAL CODES REQUIRE FLOOR SINK RIM TO BE ABOVE FINISHED FLOOR. ANCHOR FLANGE WITH CLAMPING RING AND SEEPAGE HOLES DOME STAINER FLOOR SINK DETAIL NOT TO SCALE NO -HUB FITTING DRAIN PIPE RAISED RIM INSTALLATION AS LOCAL CODES REQUIRE. NON -SHRINK GROUT FINISHED FLOOR PROVIDE WATERPROOF MEMBRANE AT ALL FLOOR DRAINS, FLOOR SINKS, AND TRENCH DRAINS. REUSE OF DOCUMENTS VERIFY SCALE BAR MEASURES ONE INCH THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS 0 THE PROPERTY OF HV ENGINEERING, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING, ADJUST SCALES COPYRIGHT, HV ENGINEERING, INC. ACCORDINGLY. ti J HV Engineering, Inc. Consulting Engineers Hall Creek Office Park 6912 220th St. SW, Suite 303 Mountlake Terrace, WA 98043 Phone: (206) 706-9669 www.hvengineering. biz Project — Stillhouse Coffee nratinr 558 Main Street Suite 108 Edmonds, WA 98020 Prepared For JD Plumbing & Fire Protection P.O. Box 1770 19495 144th Ave NE, A125 Woodinville, WA 98072 NO. DATE REVISION PARTNER IN CHARGE SDB PROJECT MANAGER PMB PROJECT ENGINEER BAQ PROJECT TEAM MEMBERS NTP, PMB, BAQ CHECK SDB --- --, -�23 TITLE PLUMBING DETAILS PROJECT NO. 2023-067 DATE AUGUST 22, 2023 91116AX61i�I�1'.LiI:�7Ji1: SHEET NUMBER P3000 1 W"CW STUB WH 1 1"HW(11 FU) 1 "CW 74"CW (13 FU W'HW (4 FU Y4"HW (7 FU LEVEL 1 /_1 "CW (13 FU) Y4"CW (8 FU) Y4"HW (6.25 FU) 74"CW (9 FU) r2"CW (1 FU) 1611CW (3 FU) -- - - r_� 5O L�S L� O J6"HW (.75 FU W'HW (2.25 FU CHANGES TO PEX FOR UG PIPING )6"HWC (1 GPM) )6"HW (2 FU) W'HW (2 FU Y2"CW (1 FU)-/ 3/4"CW (5 FU)-/ WATER RISER DIAGRAM P4.00 SCALE: NTS NOTES: 1) ABOVE GRADE WATER PIPE SIZED AS COPPER TYPE M. 2) BELOW GRADE WATER PIPE SIZED AS PEX. 2) PIPE SIZED PER SIZING TABLES SHOWN ON P0.02. 3) SITE OR OFF -SITE MANUFACTURED CUSTOM FITTINGS ARE NOT ALLOWED. 000 W'HW (4 FU) Y2"CW (1 FU) Y2"HW (2 FU) Y2"CW (1 FU) W"CW (2 FU) 3"V STUB �-----i-----,------ 2-,V i ----7 ----------------------- 1 W'V i 2"V i (6) i (6) i l w,v (2)i (0)i i i (2) I I 5 1 O I I On I I g l OI 10 I LEVEL 1 FCO I i i FD i FS i F1 i I FCO 3 L "� '0L LL n 3„W� 3„W f 3"W7 svW� 3„W (2 DFU) (2 DFU) (8 DFU) (14 DFU) 3"W 15 DFU T 4"W STUB WASTE & VENT RISER DIAGRAM SCALE: NONE NOTES: 1) ALL WASTE & VENT IS SIZED PER 2018 UPC CHAPTER 7. 2) ALL WASTE PIPING SLOPED AT %"/FT UNLESS NOTED OTHERWISE 3) ALL GREASE WASTE PIPING MUST RUN AT 2% GRADE REUSE OF DOCUMENTS VERIFY SCALE BAR MEASURES ONE INCH THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED ON ORIGINAL DRAWING HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS 0 THE PROPERTY OF HV ENGINEERING, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT IF NOT ONE INCH ON THIS WITHOUT THE WRITTEN AUTHORIZATION OF HV ENGINEERING. DRAWING, ADJUST SCALES COPYRIGHT, HV ENGINEERING, INC. ACCORDINGLY. ti HV Engineering, Inc. Consulting Engineers Hall Creek Office Park 6912 220th St. SW, Suite 303 Mountlake Terrace, WA 98043 Phone: (206) 706-9669 www.hvengineering. biz Project Stillhouse Coffee nratinr 558 Main Street Suite 108 Edmonds, WA 98020 Prepared For JD Plumbing & Fire Protection P.O. Box 1770 19495 144th Ave NE, A125 Woodinville, WA 98072 NO. DATE REVISION PARTNER IN CHARGE SDB PROJECT MANAGER PMB PROJECT ENGINEER BAQ PROJECT TEAM MEMBERS NIP, PMB, BAQ CHECK SDB =Q1d'1aa:;W:F:11 --- --, -�23 TITLE PLUMBING RISER DIAGRAMS PROJECT NO. 2023-067 DATE AUGUST 22, 2023 91116AX61i�I ify8I:i7Jia SHEET NUMBER P4000