REV1 APPROVED BLD2021-1386+Mechanical_Plan+3.13.2023_12.01.36_PM+3417534DEDICATED OUTSIDE AIR SYSTEM SCHEDULE SUPPLY FAN EXHAUST FAN ELECTRICAL POWER DESIGN OUTDOOR SUPPLY AIR SUMMER ROOM AIR WINTER / SUMMER WINTER /SUMMER FILTERS OPER WT. MARK LOCATION MAKE / MODEL SERVICE AIR TEMP (DEG F) TEMP DB (DEG F) TEMP SENS. LATENT EFFECTIVENESS SUPP. FAN FAN EXH. FAN FAN POWER SUPPLY (RETURN) NOISE dB (LBS.) REMARKS CFM ESP CFM ESP WINTER/SUMMER WINTER/SUMMER DB / RH (DEG F) EFFECTIVENESS (BHP / HP) POWER (BHP / HP) (W/CFM) FLA MCA VOLTS PH HZ TYPE (W/CFM) DOAS-1 221 EQUIP PLATFORM SWEGON / GOLD F RX07 OFFICE VENTILATION 730 0.20 860 0.21 25DB / 85DB/67WB 63.8 / 76.4 75 / 50% 86.3% / 86.3% 51.8% / 0% 0.20 / 1.54 0.18 0.30 / 1.54 0.22 11.9 13.3 220 1 60 NORMAL MERV-13 48 732 1,2,4,5,6 DOAS-2 221 EQUIP PLATFORM ALDES E1100L-FI-EC MAINTENANCE BAY 845 0.50 845 0.50 25DB / 85DB/67WB 54 / 79 75 / 50% 64.8% / 64.8% 44.1% / 31.2% - / 0.456 0.4 - / 0.456 0.4 6.0 6.4 208 1 60 NORMAL MERV 8 - 204 1,2,3,5,6 VENTILATION NOTES: 1. UNIT SHALL BE ON 24/7. PROVIDE BMS CAPABILITY TO INTERFACE TO OWNER'S DDC SYSTEM USING BACNET IP PROTOCOL. REVISED PLAN APPROVED 2. PROVIDE VFD FOR EACH FAN, AND FACTORY WIRED SERVICE OUTLET. REVISION CITY OF EDMONDS BUILDING DIVISION 3. UNIT SHALL BE HANGING FROM STRUCTURE ABOVE. Mar 13 2023 "Dowlu a W. 7-f VfAIaa 4. UNIT TO BE LOCATED ON STEEL RAILS WITH NEOPRENE PADS. CITY OFEDMONDS DEVELOPMENT SERVICES BUILDING OFFICIAL 5. PROVIDE SEISMIC RESTRAINT CALCULATIONS AND ANCHOR DETAILS AS A DEFERRED SUBMITTAL FOR ALL EQUIPMENT OVER 400 LBS. DEPARTMENT Apr 05 2023 APPROVED DATE 6. PROVIDE WITH DEFROST MODE. VRF FAN COIL UNIT SCHEDULE MARK LOCATION BASIS OF DESIGN MODEL NO. FAN COIL TYPE SUPPLY CFM ESP RATED / MAX (IN WG) COOLING (TOT) MBTUH COOLING (SENS) MBTUH HEATING MBTUH PIPE SIZES ASSOC. CU ASSOC. HRU ELECTRICAL WEIGHT LBS. REMARKS V/PH/HZ MCA POWER TYPE FCU-01 100 LOBBY MITSUBISHI TPLFYPO05FM 1 40A CASSETTE 4WAY 280 - 4,976 4,374 4,065 SEE TREE DIAGRAM CU-1 HRU-01 208/1/60 0.24 NORMAL 34 1-10 FCU-02 108 SUPERVISOR OFFICE MITSUBISHI TPLFYPO05FM 1 40A CASSETTE 4WAY 280 - 4,976 4,374 4,065 SEE TREE DIAGRAM CU-1 HRU-01 208/1/60 0.24 NORMAL 34 1-10 FCU-03 200 LOBBY MITSUBISHI TPLFYPO05FM 1 40A CASSETTE 4WAY 280 - 4,976 4,374 4,065 SEE TREE DIAGRAM CU-1 HRU-01 208/1/60 0.24 NORMAL 34 1-10 FCU-04 201 OFFICE 1 MITSUBISHI TPLFYP024EM 1 40A CASSETTE 4WAY 812 - 23,883 16,814 19,597 SEE TREE DIAGRAM CU-1 HRU-01 208/1/60 0.54 NORMAL 66 1-10 FCU-05 202 OFFICE 2 MITSUBISHI TPLFYPO 1 2FM 1 40A CASSETTE 4WAY 335 - 10,490 7,447 8,344 SEE TREE DIAGRAM CU-2 HRU-02 208/1/60 0.29 NORMAL 37 1-10 FCU-06 203 OFFICE 3 MITSUBISHI TPLFYPO 1 2FM 1 40A CASSETTE 4WAY 335 - 10,490 7,447 8,344 SEE TREE DIAGRAM CU-2 HRU-02 208/1/60 0.29 NORMAL 37 1-10 FCU-07 204 OFFICE 4 MITSUBISHI TPLFYPO 1 2FM 1 40A CASSETTE 4WAY 335 - 10,490 7,447 8,344 SEE TREE DIAGRAM CU-2 HRU-02 208/1/60 0.29 NORMAL 37 1-10 FCU-08 205 OFFICE 5 MITSUBISHI TPLFYPO 1 2FM 1 40A CASSETTE 4WAY 335 - 10,490 7,447 8,344 SEE TREE DIAGRAM CU-2 HRU-02 208/1/60 0.29 NORMAL 37 1-10 FCU-09 206 OFFICE 6 MITSUBISHI TPLFYPO 1 8EM 141 A CASSETTE 4WAY 636 - 15,734 12,560 12,361 SEE TREE DIAGRAM CU-2 HRU-02 208/1/60 0.54 NORMAL 37 1-10 FCU-10 209 ARCHIVE ROOM MITSUBISHI TPEFYPO15MH142A DUCT HIGH STATIC 494 1.00 13,112 9,953 10,507 SEE TREE DIAGRAM CU-2 HRU-02 208/1/60 1.63 NORMAL 98 1-10 FCU-11 216 BREAK ROOM MITSUBISHI TPLFYP030EM 1 40A CASSETTE 4WAY 812 - 26,224 19,619 21,014 SEE TREE DIAGRAM CU-2 HRU-02 208/1/60 0.57 NORMAL 66 1-10 FCU-12a 218 COMMISSION MTG MITSUBISHI TPLFYPO 1 5FM 1 40A CASSETTE 4WAY 390 - 14,927 9,860 12,339 SEE TREE DIAGRAM CU-1 HRU-01 208/1/60 0.35 NORMAL 37 1-10 FCU- 2b 18 OMMI N TG MITSU I LFYP015FM140A CASS E AY 90 - 14,927 9,8 0 12,339 SEE REE U- H U- 1 208 1 60 0. 5 0 AL 37 1- FCU-12c 218 COMMISSION MTG MITSUBISHI TPLFYPO15FM140A CASSETTE 4WAY 390 - 14,927 1 9,860 12,339 1 SEE TREE DIAGRAM CU-1 HRU-01 208/1/60 0.35 NORMAL 37 1-10 NOTES: 1. COOLING/HEATING CAPACITY LISTED IN SCHEDULE IS FAN COIL RATED CAPACITY. 2. VRF FAN COIL UNITS DO NOT REQUIRE ECONOMIZERS PER C403.5 EXCEPTION 3. 3. SEE "TREE" DIAGRAM ON DESIGN DOCUMENTS FOR REQUIRED REFRIGERANT PIPE SIZING. 4. FAN COILS TO HAVE DRAIN PAN AND INTEGRAL CONDENSATE PUMP. INTEGRAL CONDENSATE SWITCH PROVIDED TO PREVENT CONDENSATE OVERFLOW CONDITIONS. 5. PROVIDE FILTERS. FOR DUCTED UNITS, PROVIDE FBH SERIES FILTER BOX WITH UNIT. 6. MC AND VENDOR TO VERIFY SYSTEM REFRIGERANT CHARGE CAPACITY BASED ON FINAL EQUIPMENT LAYOUT. 7. PROVIDE SEISMIC RESTRAINT CALCULATIONS AND ANCHOR DETAILS AS A DEFERRED SUBMITTAL FOR ALL EQUIPMENT OVER 400 LBS. 8. UNITS SMALLER THAN 2,000 SUPPLY CFM TO BE SHUT DOWN VIA BAS SIGNAL UPON SMOKE DETECTION EVENT. UNITS LARGER THAN 2,000 CFM TO BE SHUT DOWN VIA FIRE ALARM SYSTEM UPON SMOKE DETECTION EVENT. 9. MINIMUM FIRST SIX FEET OF DUCT ON SUPPLY AND RETURN CONNECTED TO A DUCTED FAN COIL UNIT TO BE SOUNDLINED. 10. PROVIDE REMOTE WIRED PROGRAMMABLE THERMOSTAT AT EACH ZONE. MAKE-UP AIR UNIT SCHEDULE MARK SERVICE LOCATION FAN FAN MOTOR ELECTRICAL HEATING SECTION FILTERS BASIS OF DESIGN REMARKS CFM (TSP IN. WG) (ESP IN. WG) BHP RPM HP RPM V PH MCA MOP DISC[1] POWER TYPE KW EAT 'F LAT 'F QTY EFF SIZE (IN) MAKE MODEL LxWxH (IN) WEIGHT - LBS MAU-1 MAINTENANCE BAY & MAINTENANCE SHOP EQUIPMENT PLATFORM 221 1965 1.201 1 0.85 3377 1 3600 208 3 105.4 110 NO NORM ELECTRIC 28.6 24 70 4 MERV-8 16x2Ox2 GREENHECK MSX-P109-H12-MF 131" x 34" x 39" 1,097 1-10 NOTES: [1] YES = DISCONNECT PROVIDED BY MANUFACTURER; NO = DISCONNECT PROVIDED BY ELECTRICAL 2. CONFIGURE UNIT FOR RIGHT-HAND ACCESS, OUTSIDE AIR INTAKE FROM END OF UNIT, DISCHARGE FROM TOP 3. UNIT TO BE LOCATED ON STEEL RAILS WITH SPRING ISOLATION DAMPERS 4. FAN MOTOR SHALL MEET ALL APPLICABLE REQUIREMENTS OF THE 2018 WSEC 5. PROVIDE DRY CONTACT INTERLOCK AND CONTROL UNIT TO OPERATE IN CONJUNCTION WITH EXHAUST FAN EF-2 6. PROVIDE UNIT WITH VFD 7. PROVIDE SEISMIC RESTRAINT CALCULATIONS AND ANCHOR DETAILS AS A DEFERRED SUBMITTAL FOR ALL EQUIPMENT OVER 400 LBS. 8. UNIT SHALL BE SUPPLIED WITH A FACTORY INSTALLED C CHANNEL 10" BASE RAIL FOR HOUSEKEEPING PAD INSTALLATION 9. PROVIDE HEATER WITH SCR CONTROL 10 PROVIDE WITH CO AND NO2 SENSORS. UNIT TO OPERATE WHEN CO OR NO2 IS DETECTED, OR WHEN MANUAL OVERRIDE SWITCH IS ACTIVATED. SPLIT SYSTEM HEAT PUMP SCHEDULE TAG LOCATION SERVICE NOMINAL TON SEER HSPF AIRFLOW (CFM) COOLING CAPACITY (BTU/HR) HEATING CAPACITY (BTU/HR) ELECTRICAL WEIGHT (LBS) CU / FCU BASIS OF DESIGN SOUND POWER (dB) REMARKS VOLTS PH MCA MOP CONDENSING UNIT FAN COIL UNIT SS-01 SOUTH EXTERIOR WALL ELEVATOR MACHINE RM 2.0 21.4 11 775 24,059 16,757 208 1 19 26 153 / 46 TRUZA0241 HA70NA TPKAOA0241 KA70A 47 1-7 SS-02 SOUTH EXTERIOR WALL SERVER RM 2.0 21.4 11 775 24,059 16,757 208 1 19 26 153 / 46 TRUZA0241HA70NA TPKAOA0241KA70A 47 1-7 NOTES: 1. DISCONNECT BY ELEC CONTRACTOR. 2. INDOOR UNIT IS POWERED BY OUTDOOR UNIT. 2. NO ECONOMIZER PROVIDED PER WSEC EXCEPTION 11 SECTION C403.5. HEAT PUMP MINIMUM EFFICIENCY IS 14.0 SEER PER SEC TABLE C403.3.2(2). TO MEET EXCEPTION 11, 14.0 SEER + 15% MORE EFFCIENT = 16.1 SEER MINIMUM. 3. NO OUTSIDE AIR VENTILATION - EQUIPMENT ROOM/UNOCCUPIED SPACE. 4. PROVIDE WITH THERMOSTAT ACCESSORY: MITSUBISHI/TRANE TAR-40MAAU REMOTE CONTROLLER. 5. PROVIDE BLUE DIAMOND MAXIBLUE CONDENSATE PUMP WITH RESEVOIR & SENSOR (208V). 6. TOTAL REFRIGERANT CHARGE TO BE VERIFIED BY MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER BASED ON FINAL PIPING LAYOUT. 7. MAXIMUM REFRIGERANT PIPE LENGTH OF 165 FT BETWEEN CONDENSING AND FAN COIL UNIT. Q M 00 O O N O N N N ro City Of Edmonds Building Department Work MECHANICAL ----------------------------------------------- Address 471 ADMIRAL WAY Owner PORT OF EDMONDS- ADMIN BLDG ----------------------------------------------------------- ----------------------------------------------------- Approved Date 4/05/2023 Building Official Vawla K W. W VfAa1L Permit Number BLD2021-1386 APPROVED ALL WORK SUBJECT PLANS MUST BE TO FIELD ON JOB SITE INSPECTION FOR CODE COMPLIANCE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES SUPPLY, RETURN, EXHAUST, AND RELIEF AIR DUCTWORK INSULATION PER TABLE C403.10.1.2 - 2018 WSEC MINIMUM CLIMATE INSTALLED DUCT SYSTEM DUCT LOCATION AND USE ZONE DUCT NOTES INSULATION R-VALUE (a,b) WITHIN CONDITIONED SPACE WHERE THE 4C AND SUPPLY AIR SUPPLY DUCT CONVEYS AIR THAT IS 56 NONE 55'F OR GREATER AND 105'F OR LESS WITHIN CONDITIONED SPACE, RETURN OR DOWNSTREAM OF AN ENERGY RECOVERY 4C R-8 EXHAUST AIR MEDIA, UPSTREAM OF AN AUTOMATIC SHUTOFF DAMPER a. Insulation R-values, measured in h•ft-2� F/Btu, are for the insulation as installed and do not include film resistance. The required minimum thicknesses do not consider water vapor transmission and possible surface condensation. Insulation resistance measured on a horizontal plane in accordance with ASTM C518 at a mean temperature of 757 at the installed thickness. b. See international Mechanical Code Sections 603.12 and 604 for further details on duct insulation requirements c. Includes attics above inulated ceilings, parking garages and crawl spaces OUTDOOR AIR DUCTWORK INSULATION PER TABLE C403.10.1.1 - 2018 WSEC MINIMUM INSTALLED DUCT DUCT LOCATION AND CLIMATE AIRFLOW DUCT NOTES SYSTEM USE ZONE INSULATION R-VALUE (a,b) OUTDOOR INSIDE CONDITIONED 4C AND < 2800 SEE EXCEPTION 1 TO SECTION AIR SPACE 5B CFM R-7 C403.10.1.1 OF 2018 WSEC FOR ADDITIONAL DETAILS a• Insulation R-values, measured in h•ft^2� F/Btu, are for the insulation as installed and do not include film resistance. The required minimum thicknesses do not consider water vapor transmission and possible surface condensation. Insulation resistance measured on a horizontal plane in accordance with ASTM C518 at a mean temperature of 75'F at the installed thickness. b. See International Mechanical Code Sections 603.12 and 604 for further details on duct insulation requirements. WSEC DOAS REQUIREMENTS DOAS-1 IS REQUIRED FOR THE OFFICE SPACE (B OCCUPANCY) PER 2018 WSEC C403.3.5. DOAS-1 ALSO MEETS THE REQUIREMENTS OF C406.7 HIGH PERFORMANCE DOAS WITH A SENSIBLE EFFECTIVENESS > 80 PERCENT AND TOTAL FAN POWER < 0.5 W/CFM (SEE CALC BELOW). THE MAINTENANCE BAYS (S-1 OCCUPANCY) ARE NOT REQUIRED TO BE SERVED BY A DOAS PER C403.3.5 BUT THE PROJECT IS PROPOSING TO USE DOAS-2, MEETING THE REQUIREMENTS OF C406.6 (NOTE: DOAS-2 DOES NOT MEET THE REQUIREMENTS OF C406.7). PROVIDING A DOAS WITH ENERGY RECOVERY IN THIS SPACE STILL EXCEEDS THE MINIMUM REQUIREMENTS OF THE CODE. THE HIGH PERFORMANCE OF DOAS-1 AND THE ADDITION OF DOAS-2 FOR THE S-1 OCCUPANCY EARNS THIS PROJECT 4 CREDITS FOR SECTION C406. DOAS-1 TOTAL COMBINED FAN POWER CALCULATION: SUPPLY FAN - ELECTRIC POWER TO MOTOR(1 EXHAUST FAN - ELECTRIC POWER TO MOTOR(1 TOTAL POWER TO ALL FAN MOTORS CFM OF OUTDOOR AIR TOTAL COMBINED FAN POWER DOAS-2 TOTAL COMBINED FAN POWER CALCULATION: SUPPLY FAN - ELECTRIC POWER TO MOTOR(2) EXHAUST FAN - ELECTRIC POWER TO MOTOR(2) TOTAL POWER TO ALL FAN MOTORS CFM OF OUTDOOR AIR TOTAL COMBINED FAN POWER 0.27 HP 199 W 0.18 HP 132 W 331 W 730 CFM 0.45 W/CFM (<0.5 W/CFM) 0.456 HP 335 W 0.456 HP 335 W 670 W 845 CFM 0.79 W/CFM (<1.0 W/CFM) NOTES: (1) ELECTRIC POWER TO MOTOR PROVIDED BY SWEGON FOR USE IN SPECIFIC FAN POWER CALCULATION. MOTOR POWER IN HP PROVIDED BY ALDES. 111 ACKSON I MAI R C HI T E C T U R 311 FIRSTAVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM COFFMAN N G I N E E R S 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships vJ 0 Z O o U) > 6 C) W Q W �JQ LL 0Q� 0 0 Q U) � z � C)Q Q O W J�0 � 0c�LU 0 Z C O Z U) w >- C)C CO C) W J o LL MD W 0J� O Z ��U) U�0 ­5Q0 O Q 0� W � � 0 W Z 0 ZO 0LU H m CO Ow EE Z) w U)I_o� 0 � U) o LL w a - o w Z) U) U) Z - N M w Q •- N v cM o C'o 2Z - 4 M 3/8/23 PROJECT NO.: 210887 PROJECT MGR.: ON DRAWN BY: CEI CHECKED BY: ON SCHEDULES M003 JACKSON I MAIN ARCHITECTURE P.S. © 2021 Q r` M 00 0 0 N O N N N Q0 ASHRAE 62.1 VENTILATION CALC AREA (Az) OCCUPANT DENSITY PEOPLE OA AREA OA RATE OCCUPANTS DESIGN TOTAL OA ZONE OA - ZONE OA - OUTSIDE AIRFLOW EA RATE [CFM/SF EXHAUST AIRFLOW ROOM NAME OCCUPANCY CLASSIFICATION [SF] [#/1000 SF] RATE (Rp) (Ra) [CFM/SF] BASED ON OCCUPANTS (Pz) (Vbz=RpPz + Ez (CLG) Ez (HTG) COOLING HEATING BALANCING (CFM) OR PER FIXTURE] BALANCING [CFM] [CFM/PERSON] DENSITY (Pz) RaAz) (Voz=Vbz/Ez) (Voz=Vbz/Ez) 100 LOBBY OFFICE MAIN ENTRY LOBBIES 112 10 5 0.06 1 1.0 12 1.0 1.0 12 12 20 0 20 104A UNISEX RR RESTROOM 59 0 0 0 0 0.0 0 1.0 1.0 0 0 0 50 120 1046 URINAL RR RESTROOM 29 0 0 0 0 0.0 0 1.0 1.0 0 0 0 50 60 105 CUSTODIAL STORAGE STORAGE ROOMS 186 0 0 0 0 0.0 22 1.0 1.0 22 22 25 0 0 106 ELEV MACHINE RM NO REQUIREMENT 106 0 0 0 0 0.0 0 1.0 1.0 0 0 0 0 0 107 PARTS CAGE STORAGE ROOMS 119 0 0 0 0 0.0 14 1.0 1.0 14 14 20 0 20 108 SUPERVISOR OFFICE OFFICE SPACE 202 5 5 0 1 2.0 22 1.0 1.0 22 22 25 0 0 109 ELEC NO REQUIREMENT 75 0 0 0 0 0.0 0 1.0 1.0 0 0 0 0 0 200 LOBBY OFFICE MAIN ENTRY LOBBIES 112 10 5 0.06 1 1.0 12 1.0 1.0 12 12 20 0 20 201 OFFICE 1 OFFICE SPACE 427 5 5 0.06 2 4.0 46 1.0 1.0 46 46 45 0 0 203 OFFICE 2 OFFICE SPACE 151 5 5 0.06 1 2.0 19 1.0 1.0 19 19 20 0 0 204 OFFICE 3 OFFICE SPACE 150 5 5 0.06 1 2.0 19 1.0 1.0 19 19 20 0 0 205 OFFICE 4 OFFICE SPACE 150 5 5 0.06 1 2.0 19 1.0 1.0 19 19 20 0 0 206 OFFICE 5 OFFICE SPACE 152 5 5 0.06 1 2.0 19 1.0 1.0 19 19 20 0 0 208 OFFICE 6 OFFICE SPACE 253 5 5 0.06 1 4.0 35 1.0 1.0 35 35 35 0 0 216 BREAK ROOM BREAKROOMS 251 50 5 0.12 13 6.0 60 1.0 1.0 60 60 60 0 80 211 AUDIT OFFICE SPACE 83 5 5 0.06 0 2.0 15 1.0 1.0 15 15 20 0 0 212 SERVER NO REQUIREMENT 91 0 0 0 0 0.0 0 1.0 1.0 0 0 0 0 0 213 MEWS RR RESTROOM 67 0 0 0 0 0.0 0 1.0 1.0 0 0 0 50 120 214 WOMEN'S RR RESTROOM 67 0 0 0 0 0.0 0 1.0 1.0 0 0 0 50 120 215 CUSTODIAL JANITOR 36 0 0 0 0 0.0 0 1.0 1.0 0 0 0 1 60 9 CH E OM OF IC SP E 26 5 .06 6 36 40 0 0 218 COMMISSION MEETING RM CONFERENCE/MEETING 969 50 5 0.06 48 24.0 178 1.0 1.0 178 178 220 0 0 218A MEWS RR RESTROOM 64 0 0 0 0 0.0 0 1.0 1.0 0 0 0 50 120 218E WOMEN'S RR RESTROOM 81 0 0 0 0 0.0 0 1.0 1.0 0 0 0 50 120 CMR CORRIDOR AREA CORRIDORS 168 0 0 0.06 0 0.0 10 1.0 1.0 10 10 20 0 0 219 STORAGE STORAGE ROOMS 100 0 0 0.12 0 0.0 12 1.0 1.0 12 12 20 0 0 220 CORRIDOR CORRIDORS 518 0 0 0.06 0 0.0 31 1.0 1.0 31 31 80 0 0 73 86 VRF CONDENSING UNIT SCHEDULE UNIT SIZE SYSTEM ELECTRICAL SOUND WEIGHT MARK LOCATION CONNECTED FAN COIL UNITS MAKE MODEL REF. COP IEER (TONS) REFRIGERANT (LBS) VOLTS PH HZ MCA MOP POWER TYPE POWER (DB) (LBS) REMARKS CU-1 GROUND, SE CORNER OF SITE °' MITSUBISHI TURYE0963AN40AN 8 R410A 44.1 4.1 29.8 208 3 60 31 45.0 NORMAL 60 613 1-4 CU-2 GROUND, SE CORNER OF SITE FCU-05, 06, 07, 08, 09, 10, 11 MITSUBISHI TURYE0963AN40AN 8 R410A 38.7 4.1 29.8 208 3 60 31 45.0 NORMAL 60 613 1-4 NOTES: 1. TOTAL REFRIGERANT CHARGE TO BE VERIFIED BY MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER BASED ON FINAL PIPING LAYOUT. 2. VRF MANUFACTURER TO VERIFY "VRF TREE", REFRIGERANT PIPING ROUTING, AND SIZES BASED ON FINAL SYSTEM LAYOUT. 3. UNITS TO BE LOCATED ON STEEL RAILS WITH NEOPRENE PADS. 4. PROVIDE SEISMIC RESTRAINT CALCULATIONS AND ANCHOR DETAILS AS A DEFERRED SUBMITTAL FOR ALL EQUIPMENT OVER 400 LBS. I DIFFUSER AND GRILLE SCHEDULE MARK TYPE NECK SIZE NC MAXIMUM DUCT CONNECTION SIZE BASIS OF DESIGN REMARKS DESIGN CFM ROUND SQUARE MAKE MODEL CD-1 24x24 SQUARE CEILING SEE PLANS 35 60 SEE PLANS - TITUS TJD REFER TO RCP DIFFUSER CD-2 24x24 SQUARE CEILING SEE PLANS 25 350 SEE PLANS - TITUS MCD REFER TO RCP DIFFUSER SG-1 DUCT MOUNTED SUPPLY SEE PLANS 25 300 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE SG-2 DUCT MOUNTED DRUM SEE PLANS 25 1000 - SEE PLANS TITUS DL SURFACE MOUNT LOUVER RG-1 DUCT MOUNTED RETURN SEE PLANS 25 500 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE RG-2 24x24 CEILING RETURN SEE PLANS 25 990 - SEE PLANS TITUS 50F REFER TO RCP GRILLE, STEEL RG-3 24x8 CEILING RETURN SEE PLANS 25 620 - SEE PLANS TITUS 50F REFER TO RCP GRILLE, STEEL RG-4 12x12 CEILING RETURN SEE PLANS 25 700 - SEE PLANS TITUS 50F REFER TO RCP GRILLE, STEEL EG-1 DUCT MOUNTED EXHAUST SEE PLANS 25 500 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE TG-1 6X6 CEILING TRANSFER SEE PLANS 25 150 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE o LOUVER SCHEDULE SIZE MAX. %FREE FREE AREA PRESSURE DROP BASIS OF DESIGN MARK SERVICE LOCATION WIDTH (IN) HEIGHT (IN) CFM FPM AREA (SQ. FT.) (IN. H2O) MAKE MODEL REMARKS L-1 MAU-1 EQUIPMENT 26 26 1965 800 58% 2.7 0.08 RUSKIN ELF6375DXH 1 PLATFORM L-2 DOAS-2 OA EQUIPMENT 24 48 1575 800 54% 4.3 0.02 RUSKIN ELF6375DXH 1 PLATFORM L-3 DOAS-2 EA MAINTENANCE SHOP 24 48 1755 800 54% 4.3 0.02 RUSKIN ELF6375DXH 1 L-4 EF-2 MAINTENANCE SHOP 26 26 1965 800 58% 2.7 0.07 RUSKIN ELF6375DXH 1 L-5 KITCHEN BREAK ROOM 216 14 14 350 800 52% 0.7 0.03 RUSKIN ELF6375DXH 1 EXHAUST NOTES: L1] PROVIDE BIRD SCREEN. COORDINATE COLOR WITH ARCHITECT (UNLESS FIELD PAINTED). VRF CONDENSING UNIT SCHEDULE UNIT SIZE SYSTEM ELECTRICAL SOUND WEIGHT MARK LOCATION CONNECTED FAN COIL UNITS MAKE MODEL REF. COP IEER (TONS) REFRIGERANT (LBS) VOLTS PH HZ MCA MOP POWER TYPE POWER (DB) (LBS) REMARKS CU-1 GROUND, SE CORNER OF SITE °' MITSUBISHI TURYE0963AN40AN 8 R410A 44.1 4.1 29.8 208 3 60 31 45.0 NORMAL 60 613 1-4 CU-2 GROUND, SE CORNER OF SITE FCU-05, 06, 07, 08, 09, 10, 11 MITSUBISHI TURYE0963AN40AN 8 R410A 38.7 4.1 29.8 208 3 60 31 45.0 NORMAL 60 613 1-4 NOTES: 1. TOTAL REFRIGERANT CHARGE TO BE VERIFIED BY MECHANICAL CONTRACTOR AND EQUIPMENT MANUFACTURER BASED ON FINAL PIPING LAYOUT. 2. VRF MANUFACTURER TO VERIFY "VRF TREE", REFRIGERANT PIPING ROUTING, AND SIZES BASED ON FINAL SYSTEM LAYOUT. 3. UNITS TO BE LOCATED ON STEEL RAILS WITH NEOPRENE PADS. 4. PROVIDE SEISMIC RESTRAINT CALCULATIONS AND ANCHOR DETAILS AS A DEFERRED SUBMITTAL FOR ALL EQUIPMENT OVER 400 LBS. I DIFFUSER AND GRILLE SCHEDULE MARK TYPE NECK SIZE NC MAXIMUM DUCT CONNECTION SIZE BASIS OF DESIGN REMARKS DESIGN CFM ROUND SQUARE MAKE MODEL CD-1 24x24 SQUARE CEILING SEE PLANS 35 60 SEE PLANS - TITUS TJD REFER TO RCP DIFFUSER CD-2 24x24 SQUARE CEILING SEE PLANS 25 350 SEE PLANS - TITUS MCD REFER TO RCP DIFFUSER SG-1 DUCT MOUNTED SUPPLY SEE PLANS 25 300 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE SG-2 DUCT MOUNTED DRUM SEE PLANS 25 1000 - SEE PLANS TITUS DL SURFACE MOUNT LOUVER RG-1 DUCT MOUNTED RETURN SEE PLANS 25 500 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE RG-2 24x24 CEILING RETURN SEE PLANS 25 990 - SEE PLANS TITUS 50F REFER TO RCP GRILLE, STEEL RG-3 24x8 CEILING RETURN SEE PLANS 25 620 - SEE PLANS TITUS 50F REFER TO RCP GRILLE, STEEL RG-4 12x12 CEILING RETURN SEE PLANS 25 700 - SEE PLANS TITUS 50F REFER TO RCP GRILLE, STEEL EG-1 DUCT MOUNTED EXHAUST SEE PLANS 25 500 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE TG-1 6X6 CEILING TRANSFER SEE PLANS 25 150 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE o LOUVER SCHEDULE SIZE MAX. %FREE FREE AREA PRESSURE DROP BASIS OF DESIGN MARK SERVICE LOCATION WIDTH (IN) HEIGHT (IN) CFM FPM AREA (SQ. FT.) (IN. H2O) MAKE MODEL REMARKS L-1 MAU-1 EQUIPMENT 26 26 1965 800 58% 2.7 0.08 RUSKIN ELF6375DXH 1 PLATFORM L-2 DOAS-2 OA EQUIPMENT 24 48 1575 800 54% 4.3 0.02 RUSKIN ELF6375DXH 1 PLATFORM L-3 DOAS-2 EA MAINTENANCE SHOP 24 48 1755 800 54% 4.3 0.02 RUSKIN ELF6375DXH 1 L-4 EF-2 MAINTENANCE SHOP 26 26 1965 800 58% 2.7 0.07 RUSKIN ELF6375DXH 1 L-5 KITCHEN BREAK ROOM 216 14 14 350 800 52% 0.7 0.03 RUSKIN ELF6375DXH 1 EXHAUST NOTES: L1] PROVIDE BIRD SCREEN. COORDINATE COLOR WITH ARCHITECT (UNLESS FIELD PAINTED). DIFFUSER AND GRILLE SCHEDULE MARK TYPE NECK SIZE NC MAXIMUM DUCT CONNECTION SIZE BASIS OF DESIGN REMARKS DESIGN CFM ROUND SQUARE MAKE MODEL CD-1 24x24 SQUARE CEILING SEE PLANS 35 60 SEE PLANS - TITUS TJD REFER TO RCP DIFFUSER CD-2 24x24 SQUARE CEILING SEE PLANS 25 350 SEE PLANS - TITUS MCD REFER TO RCP DIFFUSER SG-1 DUCT MOUNTED SUPPLY SEE PLANS 25 300 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE SG-2 DUCT MOUNTED DRUM SEE PLANS 25 1000 - SEE PLANS TITUS DL SURFACE MOUNT LOUVER RG-1 DUCT MOUNTED RETURN SEE PLANS 25 500 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE RG-2 24x24 CEILING RETURN SEE PLANS 25 990 - SEE PLANS TITUS 50F REFER TO RCP GRILLE, STEEL RG-3 24x8 CEILING RETURN SEE PLANS 25 620 - SEE PLANS TITUS 50F REFER TO RCP GRILLE, STEEL RG-4 12x12 CEILING RETURN SEE PLANS 25 700 - SEE PLANS TITUS 50F REFER TO RCP GRILLE, STEEL EG-1 DUCT MOUNTED EXHAUST SEE PLANS 25 500 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE TG-1 6X6 CEILING TRANSFER SEE PLANS 25 150 - SEE PLANS TITUS 350RL SURFACE MOUNT GRILLE o LOUVER SCHEDULE SIZE MAX. %FREE FREE AREA PRESSURE DROP BASIS OF DESIGN MARK SERVICE LOCATION WIDTH (IN) HEIGHT (IN) CFM FPM AREA (SQ. FT.) (IN. H2O) MAKE MODEL REMARKS L-1 MAU-1 EQUIPMENT 26 26 1965 800 58% 2.7 0.08 RUSKIN ELF6375DXH 1 PLATFORM L-2 DOAS-2 OA EQUIPMENT 24 48 1575 800 54% 4.3 0.02 RUSKIN ELF6375DXH 1 PLATFORM L-3 DOAS-2 EA MAINTENANCE SHOP 24 48 1755 800 54% 4.3 0.02 RUSKIN ELF6375DXH 1 L-4 EF-2 MAINTENANCE SHOP 26 26 1965 800 58% 2.7 0.07 RUSKIN ELF6375DXH 1 L-5 KITCHEN BREAK ROOM 216 14 14 350 800 52% 0.7 0.03 RUSKIN ELF6375DXH 1 EXHAUST NOTES: L1] PROVIDE BIRD SCREEN. COORDINATE COLOR WITH ARCHITECT (UNLESS FIELD PAINTED). LOUVER SCHEDULE SIZE MAX. %FREE FREE AREA PRESSURE DROP BASIS OF DESIGN MARK SERVICE LOCATION WIDTH (IN) HEIGHT (IN) CFM FPM AREA (SQ. FT.) (IN. H2O) MAKE MODEL REMARKS L-1 MAU-1 EQUIPMENT 26 26 1965 800 58% 2.7 0.08 RUSKIN ELF6375DXH 1 PLATFORM L-2 DOAS-2 OA EQUIPMENT 24 48 1575 800 54% 4.3 0.02 RUSKIN ELF6375DXH 1 PLATFORM L-3 DOAS-2 EA MAINTENANCE SHOP 24 48 1755 800 54% 4.3 0.02 RUSKIN ELF6375DXH 1 L-4 EF-2 MAINTENANCE SHOP 26 26 1965 800 58% 2.7 0.07 RUSKIN ELF6375DXH 1 L-5 KITCHEN BREAK ROOM 216 14 14 350 800 52% 0.7 0.03 RUSKIN ELF6375DXH 1 EXHAUST NOTES: L1] PROVIDE BIRD SCREEN. COORDINATE COLOR WITH ARCHITECT (UNLESS FIELD PAINTED). ELECTRIC HEATER SCHEDULE ELECTRIC RADIANT HEATER SCHEDULE ELECTRICAL MARK AREA SERVED MANUFACTURER AND MODEL INSTALLATION TYPE SIZE W WEIGHT LBS REMARKS KW VOLTS/PH POWER ERH-4 SINGLE HT. MAINT. SHOP INDEECO STS INVIZATHERM CEILING MOUNT 3.0 208/1 NO 48" X 12" 38 1,2,3 ERH-8 DOUBLE HT. MAINT. BAY INDEECO STS INVIZATHERM CEILING MOUNT 4.0 208/1 NO 48" X 12" 38 1,2,3 ERH-10 DOUBLE HT. MAINT. BAY INDEECO STS INVIZATHERM CEILING MOUNT 4.0 208/1 NO 48" X 12" 38 1,2,3 EMERGENCY (LBS) ERH-1 SINGLE HT. MAINT. SHOP INDEECO STS INVIZATHERM CEILING MOUNT 3.0 208/1 NO 48" X 12" 38 1,2,3 ERH-2 SINGLE HT. MAINT. SHOP INDEECO STS INVIZATHERM CEILING MOUNT 3.0 208/1 NO 48" X 12" 38 1,2,3 ERH-3 SINGLE HT. MAINT. SHOP INDEECO STS INVIZATHERM CEILING MOUNT 3.0 208/1 NO 48" X 12" 38 1,2,3 ERH-5 SINGLE HT. MAINT. SHOP INDEECO STS INVIZATHERM CEILING MOUNT 3.0 208/1 NO 48" X 12" 38 1,2,3 ERH-6 SINGLE HT. MAINT. SHOP INDEECO STS INVIZATHERM CEILING MOUNT 3.0 208/1 NO 48" X 12" 38 1,2,3 ERH-7 DOUBLE HT. MAINT. BAY INDEECO STS INVIZATHERM CEILING MOUNT 4.0 208/1 NO 48" X 12" 38 1,2,3 ERH-9 DOUBLE HT. MAINT. BAY INDEECO STS INVIZATHERM CEILING MOUNT 4.0 208/1 NO 48" X 12" 38 1,2,3 ERH-11 DOUBLE HT. MAINT. BAY INDEECO STS INVIZATHERM CEILING MOUNT 4.0 208/1 NO 48" X 12" 38 1,2,3 ERH-12 DOUBLE HT. MAINT. BAY INDEECO STS INVIZATHERM CEILING MOUNT 4.0 208/1 NO 48" X 12" 38 1,2,3 NOTES: 1. PROVIDE THERMOSTATS, INDEECO PART #R-102. LOCATIONS SHOWN ON PLANS. 2. PROVIDE (1) INVIZATHERM WIRELESS CONTROLLER SWITCH PER EVERY 2 HEATERS. INDEECO PART #TZ-SWITCH. 120V. 3. PROVIDE 1 INVIZATHERM Z-WAVE WIRELESS CONNECTION HUB TO SERVE ALL HEATERS. INDEECO PART TZ-HUB. CN VRF HEAT RECOVERY UNIT SCHEDULE MARK LOCATION ASSOCIATED MAKE MODEL REF. TYPE # OF PORTS ELECTRICAL WEIGHT COND. VOLTS PH HZ MCA MOCP POWER TYPE (LBS) REMARKS HRU-01 219 STORAGE 3 CU-1 MITSUBISHI TCMBG1012SJ11N4 R410A 12 208 1 60 1.29 15 NORMAL 109 1,2,3,4 HRU-02 09 AR E RM CU-2 MITSUBISHI TCMBG0108SJ11N4 R410A 8 208 1 60 0.87 15 NORMAL 73 1,2,4 NOTES: 1. SEE SYSTEM TREES FOR PIPING SIZES. 2. INSTALL BOX IN ACCESSIBLE LOCATION. PROVIDE MINIMUM ACCESS SERVICE AS REQUIRED BY MANUFACTURER. 3. INCLUDES OPEN PORTS FOR FLEXIBILTY. QUANTITY OF FAN COILS UNKNOWN FOR FUTURE LEASABLE OFFICE BUILD OUT. 4. PROVIDE CONDENSATE PUMP WITH RESEVOIR AND SENSOR - 208V. TAG LOCATION AREA SERVED FAN MOTOR DRIVE BASIS OF DESIGN EF-2 102 MAINT. BAY MAINTENANCE BAY & 1 NOTES: FAN SCHEDULE INLET WEIGHT REMARKS CFM RPM ESP HP VOLTS PH TYPE DBA LBS EF-1 109 ELEC ELECTRICAL RM 150 1,445 0.25 1/15 115 1 DIRECT GREENHECK SQ-70-VG 44 32 2,3,5,6 MAINTENANCE SHOP '965 1,869 0.75 1 208 3 DIRECT GREENHECK QEID-12 67 139 3,4,5,6,7 CF-1 102 MAINT. BAY MAINTENANCE BAY - 191 - 1 208 3 DIRECT BIG ASS FANS PF8-08 < 55 135 3,8 CF-2 103 MAINT. BAY MAINTENANCE SHOP 9,676 170 - 35.4W 208 1 DIRECT BIG ASS FANS MK-161-05 < 35 34 9 CF-3 103 MAINT. BAY MAINTENANCE SHOP 9,676 170 - 35.4W 208 1 DIRECT BIG ASS FANS MK-161-05 < 35 34 9 CF-4 103 MAINT. BAY MAINTENANCE SHOP 9,676 170 - 35.4W 208 1 DIRECT BIG ASS FANS MK-161-05 < 35 34 9 1. PROVIDE DISCONNECT SWITCH, FAN TO OPERATE CONTINUOUSLY. 2. PROVIDE DISCONNECT SWITCH AND THERMOSTAT. REFER TO SEQUENCE OF OPERATIONS. 3. FAN MOTORS SHALL MEET 2018 WSEC. 4. PROVIDE WITH BACKDRAFT DAMPER. 5. PROVIDE WITH HANGING ISOLATORS, SPRING TYPE. 6. FAN TO HAVE "VARI-GREEN" MOTOR WITH MANUAL SPEED POT. FOR BALANCING INSTALLED ON FAN. 7. PROVIDE DISCONNECT SWITCH. FAN TO BE CONTROLLED TO OPERATE WITH MAU-1 8. HEAVY-DUTY INDUSTRIAL CEILING FAN WITH 8FT DIAMETER. PROVIDE WITH STANDARD CONTROLLER. MANUAL ON/OFF AND VARIABLE SPEED CONTROL. 9. CEILING FAN, 60 INCH DIAMETER, INDOOR, STANDARD MOUNT, LESS LIGHT KIT, PROVIDE WITH 36 INCH DOWNROD, FIXED WALL MOUNT CONTROLLER. U00 ) ACKSON MAI RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM C®FMAN N G I N E E R S 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 I fix 206.624.3775 coffman.c m LASTING creativity I results I relationships vJ Z O VRF HEAT RECOVERY UNIT SCHEDULE MARK LOCATION ASSOCIATED MAKE MODEL REF. TYPE # OF PORTS ELECTRICAL WEIGHT COND. VOLTS PH HZ MCA MOCP POWER TYPE (LBS) REMARKS HRU-01 219 STORAGE 3 CU-1 MITSUBISHI TCMBG1012SJ11N4 R410A 12 208 1 60 1.29 15 NORMAL 109 1,2,3,4 HRU-02 09 AR E RM CU-2 MITSUBISHI TCMBG0108SJ11N4 R410A 8 208 1 60 0.87 15 NORMAL 73 1,2,4 NOTES: 1. SEE SYSTEM TREES FOR PIPING SIZES. 2. INSTALL BOX IN ACCESSIBLE LOCATION. PROVIDE MINIMUM ACCESS SERVICE AS REQUIRED BY MANUFACTURER. 3. INCLUDES OPEN PORTS FOR FLEXIBILTY. QUANTITY OF FAN COILS UNKNOWN FOR FUTURE LEASABLE OFFICE BUILD OUT. 4. PROVIDE CONDENSATE PUMP WITH RESEVOIR AND SENSOR - 208V. TAG LOCATION AREA SERVED FAN MOTOR DRIVE BASIS OF DESIGN EF-2 102 MAINT. BAY MAINTENANCE BAY & 1 NOTES: FAN SCHEDULE INLET WEIGHT REMARKS CFM RPM ESP HP VOLTS PH TYPE DBA LBS EF-1 109 ELEC ELECTRICAL RM 150 1,445 0.25 1/15 115 1 DIRECT GREENHECK SQ-70-VG 44 32 2,3,5,6 MAINTENANCE SHOP '965 1,869 0.75 1 208 3 DIRECT GREENHECK QEID-12 67 139 3,4,5,6,7 CF-1 102 MAINT. BAY MAINTENANCE BAY - 191 - 1 208 3 DIRECT BIG ASS FANS PF8-08 < 55 135 3,8 CF-2 103 MAINT. BAY MAINTENANCE SHOP 9,676 170 - 35.4W 208 1 DIRECT BIG ASS FANS MK-161-05 < 35 34 9 CF-3 103 MAINT. BAY MAINTENANCE SHOP 9,676 170 - 35.4W 208 1 DIRECT BIG ASS FANS MK-161-05 < 35 34 9 CF-4 103 MAINT. BAY MAINTENANCE SHOP 9,676 170 - 35.4W 208 1 DIRECT BIG ASS FANS MK-161-05 < 35 34 9 1. PROVIDE DISCONNECT SWITCH, FAN TO OPERATE CONTINUOUSLY. 2. PROVIDE DISCONNECT SWITCH AND THERMOSTAT. REFER TO SEQUENCE OF OPERATIONS. 3. FAN MOTORS SHALL MEET 2018 WSEC. 4. PROVIDE WITH BACKDRAFT DAMPER. 5. PROVIDE WITH HANGING ISOLATORS, SPRING TYPE. 6. FAN TO HAVE "VARI-GREEN" MOTOR WITH MANUAL SPEED POT. FOR BALANCING INSTALLED ON FAN. 7. PROVIDE DISCONNECT SWITCH. FAN TO BE CONTROLLED TO OPERATE WITH MAU-1 8. HEAVY-DUTY INDUSTRIAL CEILING FAN WITH 8FT DIAMETER. PROVIDE WITH STANDARD CONTROLLER. MANUAL ON/OFF AND VARIABLE SPEED CONTROL. 9. CEILING FAN, 60 INCH DIAMETER, INDOOR, STANDARD MOUNT, LESS LIGHT KIT, PROVIDE WITH 36 INCH DOWNROD, FIXED WALL MOUNT CONTROLLER. U00 ) ACKSON MAI RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM C®FMAN N G I N E E R S 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 I fix 206.624.3775 coffman.c m LASTING creativity I results I relationships vJ Z O TAG LOCATION AREA SERVED FAN MOTOR DRIVE BASIS OF DESIGN EF-2 102 MAINT. BAY MAINTENANCE BAY & 1 NOTES: FAN SCHEDULE INLET WEIGHT REMARKS CFM RPM ESP HP VOLTS PH TYPE DBA LBS EF-1 109 ELEC ELECTRICAL RM 150 1,445 0.25 1/15 115 1 DIRECT GREENHECK SQ-70-VG 44 32 2,3,5,6 MAINTENANCE SHOP '965 1,869 0.75 1 208 3 DIRECT GREENHECK QEID-12 67 139 3,4,5,6,7 CF-1 102 MAINT. BAY MAINTENANCE BAY - 191 - 1 208 3 DIRECT BIG ASS FANS PF8-08 < 55 135 3,8 CF-2 103 MAINT. BAY MAINTENANCE SHOP 9,676 170 - 35.4W 208 1 DIRECT BIG ASS FANS MK-161-05 < 35 34 9 CF-3 103 MAINT. BAY MAINTENANCE SHOP 9,676 170 - 35.4W 208 1 DIRECT BIG ASS FANS MK-161-05 < 35 34 9 CF-4 103 MAINT. BAY MAINTENANCE SHOP 9,676 170 - 35.4W 208 1 DIRECT BIG ASS FANS MK-161-05 < 35 34 9 1. PROVIDE DISCONNECT SWITCH, FAN TO OPERATE CONTINUOUSLY. 2. PROVIDE DISCONNECT SWITCH AND THERMOSTAT. REFER TO SEQUENCE OF OPERATIONS. 3. FAN MOTORS SHALL MEET 2018 WSEC. 4. PROVIDE WITH BACKDRAFT DAMPER. 5. PROVIDE WITH HANGING ISOLATORS, SPRING TYPE. 6. FAN TO HAVE "VARI-GREEN" MOTOR WITH MANUAL SPEED POT. FOR BALANCING INSTALLED ON FAN. 7. PROVIDE DISCONNECT SWITCH. FAN TO BE CONTROLLED TO OPERATE WITH MAU-1 8. HEAVY-DUTY INDUSTRIAL CEILING FAN WITH 8FT DIAMETER. PROVIDE WITH STANDARD CONTROLLER. MANUAL ON/OFF AND VARIABLE SPEED CONTROL. 9. CEILING FAN, 60 INCH DIAMETER, INDOOR, STANDARD MOUNT, LESS LIGHT KIT, PROVIDE WITH 36 INCH DOWNROD, FIXED WALL MOUNT CONTROLLER. U00 ) ACKSON MAI RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM C®FMAN N G I N E E R S 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 I fix 206.624.3775 coffman.c m LASTING creativity I results I relationships vJ Z O ACKSON MAI RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM C®FMAN N G I N E E R S 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 I fix 206.624.3775 coffman.c m LASTING creativity I results I relationships vJ Z O Q W W Q O� J Q 0 z � � Q 0 O W JMo � � U Co W REVISION Mar 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z 0 O K u, � G C) w >_ 00 J O� Q W � CIJ� > ILmQQ z 0 0 m o � � �::) L`w o Q� - 3/8123 PROJECT NO.: 210887 PROJECT MGR.: ON DRAWN BY: CEI CHECKED BY: ON SCHEDULES M004 JACKSON I MAIN ARCHITECTURE P.S. ©2021 SHEET NOTES: VRF & DOAS ZONE 20x10 OA DUCT DOAS-2 (ABOVE) 2414 OA DUCT DOAS-1 (BELOW) L-1 26x26 OA LOUVER L-2 48x24 OA LOUVER PROVIDE MECHANICAL DAMPER -ON EACH DUCT- 24x 14 EA DUCT TO DOAS-1 (BELOW) L-3 48x24 EA LOUVER L-4 26x26 EA LOUVER T T3 T 5 1 COORDINATE HEATER LAHAu�) I -VV I "T-tvl d. V IVI LOCATIONS WITH LIGHTING HOOD P»CAI AND ROLLUP DOORS (350 CFM) I (TYP.) HEATING AND VENTILATION ONLY ZONE - LEVEL 2 HVAC PLAN- 777 SCALE: 3/16" = 1'-0" & DOAS ZONE — — ----(:C) KEYNOTES: CONTRACTOR VERIFY SERVER ROOM HEAT LOAD PRIOR TO ORDERING SPLIT SYSTEM HEAT PUMP UNIT. ACTUAL HEAT LOAD HAS NOT YET BEEN RECEIVED. 1200 SOUND LINED SHEET METAL TRANSFER ABOVE CEILING. INSTALL CEILING FAN PER MANUFACTURER'S REQUIRED CLEARANCES. MINIMUM CLEARANCE 4FT BELOW CEILING AND 2FT ON SIDES. ® RADIANT HEATER MOUNTED FROM CEILING/STRUCTURAL ABOVE WITH BOTTOM OF UNIT ELEVATION AT 21'-6". III�:aS'Gl1mbRICZ,11$11liliII:I T 21'-6" © PROVIDE 12X8 DOOR GRILLE TO TRANSFER CONDITIONED AIR INTO AV CLOSET. BASIS OF DESIGN: TITUS CT-700L. COORDINATE REQUIRED LOCATION IN DOOR WITH ARCHITECTURAL FOR DOOR PANEL TYPE ELEVATION. PROVIDE SOUNDLINED BOOT FOR AIR TRANSFER. EXTEND BOOT THROUGH FULL HEIGHT RESTROOM WALL AND TERMINATE ABOVE CORRIDOR CEILING. ® INSTALL PER MANUFACTURER'S DIRECTIONS. CEILING TILE TO BE REMOVABLE FOR ACCESS WHERE INSPECTION HOLE IS REQUIRED BY MANUFACTURER. Nil 11 ACKSON I MAID RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM COFFMAN N G I N E E R S 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 I fax 206.624.3775 coffman.com LASTING creativity I results I relationships U) 0 z O o 0400 � w�a' W 0 J< LL in 0 0 Q ") 0 ~ ZOO < O W J�0 � U c� W REVISION Mar 13 2023 CITY E DEVELOPMENT SERVICES DEPARTMENT 0 z CD Oz 20 Q J WD LL m Oz I— — 00 0- Q W, U) O W >- 00 C) 3: Q 0 J a ry Cn U2i0 )QO °�0 0- � W J Q 0 z0 m LL co U)t=w o U) w a - zN w N QL o p 3/8/23 PROJECT NO.: 210887 PROJECT MGR.: ON DRAWN BY: CEI CHECKED BY: ON LEVEL 2 HVAC PLAN M1.2 JACKSON I MAIN ARCHITECTURE P.S. © 2021 SHEET NOTES: VRF & DO/ Q co 0 0 N O N N N O LEVEL 2 HVAC PIPING PLAN SCALE: 3/16" = 1'-0" KEYNOTES: ALL UNITS PROVIDED WITH INTEGRAL CONDENSATE PUMP. CONDENSATE TO BE PUMPED UP AS HIGH AS POSSIBLE IN CEILING SPACE THEN DRAINED BY GRAVITY TO DRAIN OR MOP SINK AS SHOWN. CONDENSATE FOR FUTURE UNITS IN LEASABLE OFFICE TO BE ROUTED TO TAILPIECE OF SINK OR LAV LOCATED IN LEASABLE OFFICE SPACE. REFRIGERANT PIPE ROUTING SHOWN FOR CONCEPTUAL PURPOSES ONLY. REFER TO VRF PIPING TREES ON SHEET M2.2 FOR MORE DETAILS. ® ALL 3 REF PIPES FOLLOW SAME ROUTE BUT ONLY ONE PIPE IS SHOWN HERE FOR CLARITY. 2 REF PIPES ARE ROUTED FROM HRU TO EACH FCU BUT ONLY ONE PIPE SHOWN HERE FOR CLARITY. REF PIPING ROUTED TO LEVEL 2 FCU'S. REFER TO VRF SHEET M2.2. COORDINATE PIPE ROUTING TO AVOID ROOF HATCH. SEE ARCHITECTURAL FOR ROOF HATCH DETAILS. FAI 111 ACKSON I MAI RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM COFFMAN N G I N E E R S 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 I fax 206.624.3775 coffman.com LASTING creativity I results I relationships v / z O o 04 � W W (]�JQ LL in 0 0 Q ") � ~ ZOO � < O W J�o � U c� w REVISION Mar 13 2023 CITY E DEVELOPMENT SERVICES DEPARTMENT z CD 0 z L UU) " j >- o co W D o L.Lm0J� 0 z �rycn U2iC, ---)Q0 O 0-Qw 0 °moo w J Q 0 O H m LL co U)t=w U) o w - z Na- w N Q L O p - 3/8/23 PROJECT NO.: 210887 PROJECT MGR.: ON DRAWN BY: CEI CHECKED BY: ON LEVEL 2 HVAC PIPING PLAN M 1.4 JACKSON I MAIN ARCHITECTURE P.S. © 2021 SHEET NOTES: Port of Edmonds DIAGRAM SYMBOL LEGEND DISPLAY DESCRIPTION F/ POWER WIRE CONTROL WIRE REF. PIPE PIPING AND CONTROLS SYMBOL BRANCH PIPE MODEL NAME J 1 CMY-R301 S-G SYMBOL LIQUID PIPE/GAS PIPE SIZE P1 3/8 / 5/8 P2 1/4 / 1/2 P3 3/4 / 7/8 SYMBOL MODELNUMBER MA TAR-40MAAU Diamond System Builder sw: 4.4.3.44 db: 4.4.3.17 2/24/2023 11:41 AM Q 00 0 0 N O N N N O TE-200A 100-240V CITY MULTI CONT.N PAGE SYSTEM SCHEMATIC DWG. 16-2 REMARKS - Originator: Ben Dionne Comments: SS-01 TRUZA0241HA70NA [SS-CU-01] 001 E P1 TB4 G 001 _ TB5 (G-pi J TPKAOA0241KA70A 22-16-2 AWG M IDU-Al This drawing is schematic in nature. Final routing of piping & wiring shall be determined by the installing contractor and/or designer of record Additional refrigerant charge is needed depending on the size and length of extended piping. Please refer the amount of pre -charge and the formula of calculation which is mentioned on the data book. 1.25mm(16 AWG) : 1.25mm(16 AWG) or more. 0.75mm(20 AWG) : between 0.5mm(24 AWG) and 0.75mm(20 AWG). SS-02 TRUZA0241 HA70NA [SS-CU-02] 002 E P1 TB4 G 002 TB5 I Gp2 J TPKAOA0241 KA70A 22-16-2 AWG IDU-B1 CU-1 TURYE0963AN40AN [CU-1] TB7 053 TB3 G SW4 Function 935 OFF (s) P3 A HRU-01 TCMBG1012SJ11N4 TB2 054 1 2 3 4 5 6 7 P2 P2 �P2 �P1 �P2 P2 P2 G 003 004 005 G *2P2L-1.2AWG 007 G 008 G *TPLFYP015FM140A B5TGp3 GpGp5 Gp8 B15 T5TB15 TB5TB15 Gp1 TB5TB15 GPT PO5FTPLFYPO05FMI40A TPLFYPO05FM140A TPLFYMI40AP024EM140B 15FM140A TPLFYPO15FM140A 22AWG22-16-2 A FCU-01 I FCU-02 I FCU-03 j I FCU-04 I FCU-12a FCU-12b FCU-12c NOTE: PIPING TREE PROVIDED FOR PRELIMINARY INFORMATION ONLY. VRF MANUFACTURER SHALL PROVIDE ACTUAL TREE USED FOR PIPING SIZING INSTALLATION BASED ON ACTUAL FIELD LENGTHS AND ELBOWS. (*'-1 � VRF SYST �.2SCALE: NO SCALE EM PIPING & WIRING SCHEMATIC P3 A 1 AWG(S)I �TB2 060 1 2 3 4 TURYE0963AN40AN [CU-2] TB7 059 TB3 G SW4 Function 935 OFF (S) HRU-02 TCMBG0108SJ 11 N4 G 7 P2 P2 �P2 �P2 �P2 P2 P1 G*22-16-2 G G G G*2p2L-1 009 011 012 013 014 B5TB15 GO TB5TB15 Gp10 T135TB15 Gp11 TB5TB15 Gp12 T135TI315 Gp13 4 TPLFYPO12FMI40A140A TPLFYPO12FMI40A TPLFYPO12FM140A TPLFYPOIBEM141B TPEFYPO15MH142A140B 22-16-2 AWGG 22-16-2AWG 22-i6-2AWG 22-16-2 AWG 22-i6-2 AWGG FCU-05 FCU-06 j, FCU-07 1, FCU-08j, FCU-09 , FCU-10 j, FCU-11 KEYNOTES: Nil T ACKSON I MAID RCHITECTUR 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM COFFMAN N G I N E E R S 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships V ) 0 Z O o U) > � Lu Q W OJQ LL 0 Q 0 00�U) Q O N� I..L Z Q O w J�0 U c� LU REVISION Mar 13 2023 CITY E DEVELOPMENT SERVICES DEPARTMENT 0 Z CD 0 z CN �U) " 1 >_ o 00 W ::) 0 LLm0J� 0 . Z ��VJ U 2 i0 5 �<0 O O 0. 0- ['_ � I I0 W J Q 0 O H m co LL U w o Of � W D- — ZN LJJ N Q L O C) Q3/8/23 PROJECT NO.: 210887 PROJECT MGR.: ON DRAWN BY: CEI CHECKED BY: ON VRF SYSTEM SCHEMATIC M202 JACKSON i MAIN ARCHITECTURE P.S. © 2021 SHEET NOTES: Room Checksums By COFFMAN ENGINEERS, INC. 218 Commision Mtg Room New COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 7 / 11 Mo/Hr: 7 / 11 Mo/Hr: Heating Design Cooling Heating Outside Air: OADB/WB/HR: 74 / 61 / 60 OADB: 74 OADB: 25 SADB 55.0 77.1 Ra Plenum 75.0 70.0 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.4 70.0 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 75.4 70.0 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.0 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.0 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.0 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 358 0 358 1 358 1 Roof Cond -1,167 -1,167 9.83 Glass Solar 7,738 0 7,738 25 7,738 31 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond -182 0 -182 -1 -182 -1 Glass/Door Cond -2,497 -2,497 21.03 Cooling Heating Wall Cond 908 0 908 3 908 4 Wall Cond -1,151 -1,151 9.70 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 1,128 1,128 Floor 0 0 0 0.00 0 Floor 0 0 0.00 Terminal 1,128 1,128 Adjacent Floor 0.00 0.00 0.00 0.00 0.00 0.00 Adjacent Floor 0.00 0.00 0.00 Main Fan 1,128 1,128 Infiltration -166 -166 -1 -66 0 Infiltration -2,256 -2,256 19.00 Sec Fan 0 0 Sub Total =_> 8,656 0 8,656 28 8,756 35 Sub Total =_> -7,071 -7,071 59.55 Nom Vent 220 220 AHU Vent 220 220 Internal Loads Internal Loads Infil 46 46 Lights 2,646 661 3,307 11 2,646 11 Lights 0 0 0.00 MinStop/Rh 113 113 People 12,000 0 12,000 39 6,000 24 People 0 0 0.00 Return 1,394 1,394 Misc 7,693 0 7,693 25 7,693 31 Misc 0 0 0.00 Exhaust 266 266 Sub Total =_> 22,339 661 23,000 75 16,339 66 Sub Total =_> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 0 0 0 0 0 0 Ceiling Load 0 0 0.00 Leakage Dwn 0 0 Ventilation Load -796 0 -796 -3 -317 -1 Ventilation Load -1,209 -1,209 10.18 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing -490 -490 4.13 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 0 0.00 ENGINEERING CKS Exhaust Heat -126 -126 0 OA Preheat Diff. -3,104 26.14 Sup. Fan Heat 0 0 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 19.5 19.5 Duct Heat Pkup 0 0 0 System Plenum Heat 0 0.00 cfm/ft' 1.16 1.16 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 440.22 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 378.34 Btu/heft' 31.72 -12.25 Grand Total =_> 30,199 535 30,734 100.00 24,778 100.00 Grand Total ==> -8,770 -11,874 100.00 No. People 24.0 24.8/1000 ft' COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DBIWB/HR Gross Total Glass Capacity Coil Airflow Ent Lvg ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft' (%) MBh cfm °F °F Main Clg 2.6 30.7 25.3 1,128 75.4 62.6 65.9 55.0 53.3 59.0 Floor 969 Main Htg -8.8 1,128 70.0 77.1 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 0 Aux Htg 0.0 0 0.0 0.0 Opt Vent 0.0 0.0 0.0 220 63.1 54.7 51.3 63.1 54.7 51.3 Int Door 1 Preheat 0.0 0 0.0 0.0 ExFlr 0 Total 2.6 30.7 Roof 969 0 0 Humidif 0.0 0 0.0 0.0 Wall 621 152 24 Opt Vent -3.1 220 52.2 65.0 Ext Door 0 0 0 Total -11.9 Project Name: TRACE® 700 v6.3.5 calculated at 06:27 PM on 02/23/2023 Dataset Name: 210887_POE_022023.TRC Alternative - 1 System Checksums Report Page 19 of 22 Room Checksums By COFFMAN ENGINEERS, INC. 219 Storage COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 7 / 15 Mo/Hr: 7 / 16 Mo/Hr: Heating Design Cooling Heating Outside Air: OADB/WB/HR: 81 / 64 / 63 OADB: 80 OADB: 25 SADB 55.0 90.0 Ra Plenum 75.0 70.0 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 76.4 70.0 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 76.4 70.0 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.0 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.0 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.0 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 166 0 166 23 181 32 Roof Cond -120 -120 14.08 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 26 26 Floor 0 0 0 0.00 0 Floor 0 0 0.00 Terminal 26 26 Adjacent Floor 0.00 0.00 0.00 0.00 0.00 0.00 Adjacent Floor 0.00 0.00 0.00 Main Fan 26 26 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 166 0 166 23 181 32 Sub Total =_> -120 -120 14.08 Nom Vent 20 20 AHU Vent 20 20 Internal Loads Internal Loads Infil 0 0 Lights 273 68 341 47 273 48 Lights 0 0 0.00 MinStop/Rh 3 3 People 0 0 0 0 0 0 People 0 0 0.00 Return 46 46 Misc 0 0 0 0 0 0 Misc 0 0 0.00 Exhaust 20 20 Sub Total =_> 273 68 341 47 273 48 Sub Total =_> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 0 0 0 0 0 0 Ceiling Load 0 0 0.00 Leakage Dwn 0 0 Ventilation Load 254 0 254 35 119 21 Ventilation Load -110 -110 12.85 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing -343 -343 40.08 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 0 0.00 ENGINEERING CKS Exhaust Heat -30 -30 -4 OA Preheat Diff. -282 32.99 Sup. Fan Heat 0 0 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 76.7 76.7 Duct Heat Pkup 0 0 0 System Plenum Heat 0 0.00 cfm/ft' 0.26 0.26 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 427.30 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 1,638.62 Btu/heft' 7.32 -8.55 Grand Total =_> 694 39 732 100.00 573 100.00 Grand Total ==> -573 -855 100.00 No. People 0.0 0.0/1000 ft' COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Capacity Coil Airflow Ent Lvg ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft' (%) MBh cfm °F °F Main Clg 0.1 0.7 0.6 26 76.4 63.0 65.9 55.0 53.4 59.2 Floor 100 Main Htg -0.6 26 70.0 90.0 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 0 Aux Htg 0.0 0 0.0 0.0 Opt Vent 0.0 0.0 0.0 20 63.1 54.7 51.3 63.1 54.7 51.3 Int Door 1 Preheat 0.0 0 0.0 0.0 ExFlr 0 Total 0.1 0.7 Roof 100 0 0 Humidif 0.0 0 0.0 0.0 Wall 0 0 0 Opt Vent -0.3 20 52.2 65.0 Ext Door 0 0 0 Total -0.9 Project Name: TRACE® 700 v6.3.5 calculated at 06:27 PM on 02/23/2023 Dataset Name: 210887_POE_022023.TRC Alternative - 1 System Checksums Report Page 21 of 22 Q M O O O N O N N N O 0 Room Checksums By COFFMAN ENGINEERS, INC. 218C CMR Corridor COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 7/15 Mo/Hr: 7 / 16 Mo/Hr: Heating Design Cooling Heating Outside Air: OADB/WB/HR: 81 / 64 / 63 OADB: 80 OADB: 25 SADB 55.0 77.1 Ra Plenum 75.0 70.0 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 76.7 70.0 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 76.7 70.0 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.0 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.0 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.0 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 279 0 279 30 305 35 Roof Cond -202 -202 34.04 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 40 40 Floor 0 0 0 0.00 0 Floor 0 0 0.00 Terminal 40 40 Adjacent Floor 0.00 0.00 0.00 0.00 0.00 0.00 Adjacent Floor 0.00 0.00 0.00 Main Fan 40 40 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 279 0 279 30 305 35 Sub Total =_> -202 -202 34.04 Nom Vent 20 20 AHU Vent 20 20 Internal Loads Internal Loads Infil 0 0 Lights 459 115 573 61 459 52 Lights 0 0 0.00 MinStop/Rh 4 4 People 0 0 0 0 0 0 People 0 0 0.00 Return 60 60 Misc 0 0 0 0 0 0 Misc 0 0 0.00 Exhaust 20 20 Sub Total =_> 459 115 573 61 459 52 Sub Total =_> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 0 0 0 0 0 0 Ceiling Load 0 0 0.00 Leakage Dwn 0 0 Ventilation Load 125 0 125 13 119 13 Ventilation Load -110 -110 18.49 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 0 0.00 ENGINEERING CKS Exhaust Heat -38 -38 -4 OA Preheat Diff. -282 47.48 Sup. Fan Heat 0 0 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 49.8 49.8 Duct Heat Pkup 0 0 0 System Plenum Heat 0 0.00 cfm/ft' 0.24 0.24 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 508.84 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 2,129.83 Btu/heft' 5.63 -3.54 Grand Total =_> 863 77 940 100.00 882 100.00 Grand Total ==> -312 -594 100.00 No. People 0.0 0.0/1000 ft' COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DBIWB/HR Gross Total Glass Capacity Coil Airflow Ent Lvg ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft' (%) MBh cfm °F °F Main Clg 0.1 1.0 1.0 40 76.7 63.1 65.9 55.0 55.0 65.5 Floor 168 Main Htg -0.3 40 70.0 77.1 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 0 Aux Htg 0.0 0 0.0 0.0 Opt Vent 0.0 0.0 0.0 20 63.1 54.7 51.3 63.1 54.7 51.3 Int Door 1 Preheat 0.0 0 0.0 0.0 ExFlr 0 Total 0.1 1.0 Roof 168 0 0 Humidif 0.0 0 0.0 0.0 Wall 0 0 0 Opt Vent -0.3 20 52.2 65.0 Ext Door 0 0 0 Total -0.6 Project Name: TRACE® 700 v6.3.5 calculated at 06:27 PM on 02/23/2023 Dataset Name: 210887_POE_022023.TRC Alternative - 1 System Checksums Report Page 20 of 22 Room Checksums By COFFMAN ENGINEERS, INC. 220 Corridor COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 7 / 15 Mo/Hr: 7 / 16 Mo/Hr: Heating Design Cooling Heating Outside Air: OADB/WB/HR: 81 / 64 / 63 OADB: 80 OADB: 25 SADB 55.0 77.9 Ra Plenum 75.0 70.0 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 76.8 70.0 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 76.8 70.0 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.0 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.0 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.0 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 877 0 877 29 956 35 Roof Cond -635 -635 32.81 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 14 14 0 14 0 Partition/Door -14 -14 0.70 Diffuser 126 126 Floor 0 0 0 0.00 0 Floor 0 0 0.00 Terminal 126 126 Adjacent Floor 0.00 0.00 0.00 0.00 0.00 0.00 Adjacent Floor 0.00 0.00 0.00 Main Fan 126 126 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 890 0 890 29 969 35 Sub Total =_> -648 -648 33.51 Nom Vent 60 60 AHU Vent 60 60 Internal Loads Internal Loads Infil 0 0 Lights 1,439 360 1,799 59 1,439 52 Lights 0 0 0.00 MinStop/Rh 13 13 People 0 0 0 0 0 0 People 0 0 0.00 Return 186 186 Misc 0 0 0 0 0 0 Misc 0 0 0.00 Exhaust 60 60 Sub Total =_> 1,439 360 1,799 59 1,439 52 Sub Total =_> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 0 0 0 0 0 0 Ceiling Load 0 0 0.00 Leakage Dwn 0 0 Ventilation Load 478 0 478 16 356 13 Ventilation Load -330 -330 17.04 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing -110 -110 5.69 Ov/Undr Sizing 0 0 0 0 0 Exhaust Heat 0 0.00 ENGINEERING CKS Exhaust Heat -116 -116 -4 OA Preheat Diff. -847 43.76 Sup. Fan Heat 0 0 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 47.7 47.7 Duct Heat Pkup 0 0 0 System Plenum Heat 0 0.00 cfm/ft' 0.24 0.24 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 494.72 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 2,072.73 Btu/heft' 5.79 -3.67 Grand Total =_> 2,807 244 3,051 100.00 2,764 100.00 Grand Total ==> -1,088 -1,934 100.00 No. People 0.0 0.0/1000 ft' COOLING COIL SELECTION AREAS HEATING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Capacity Coil Airflow Ent Lvg ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft' (%) MBh cfm °F °F Main Clg 0.3 3.1 3.0 126 76.8 63.1 65.9 55.0 54.9 65.4 Floor 527 Main Htg -1.1 126 70.0 77.9 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 49 Aux Htg 0.0 0 0.0 0.0 Opt Vent 0.0 0.0 0.0 60 63.1 54.7 51.3 63.1 54.7 51.3 Int Door 1 Preheat 0.0 0 0.0 0.0 ExFlr 0 Total 0.3 3.1 Roof 527 0 0 Humidif 0.0 0 0.0 0.0 Wall 0 0 0 Opt Vent -0.9 60 52.2 65.0 Ext Door 0 0 0 Total -1.9 Project Name: TRACE® 700 v6.3.5 calculated at 06:27 PM on 02/23/2023 Dataset Name: 210887_POE_022023.TRC Alternative-1 System Checksums Report Page 22 of 22 KEYNOTES: ACKSON I MAI R C H I T E C T U R 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM COFFMAN N G I N E E R S 1101 2nd Ave., Suite 400 1 Seattle, WA 98101 ph 206.623.0717 1 fax 206.624.3775 coffman.com LASTING creativity I results I relationships v / 0 Z 0 _C) IN W L �JQ O ��U' 1M � 0 O O J M 0 U cM LU REVISION Mar 13 2023 CITY E DEVELOPMENT SERVICES DEPARTMENT 0 Z C� 0 z CN L 'v^, UJ o Q J [). W o L.LmOJ� 0 Z ��cn U Z � LLI ---)Q0 O O. 0 I..L 0- "t w J 0 H m m O Z) LL � 1-- W of U) W D_ - O - N Z W N Q c � p O 3/8/23 PROJECT NO.: 210887 PROJECT MGR.: ON DRAWN BY: CEI CHECKED BY: ON HVAC LOAD CALCS M304 JACKSON I MAIN ARCHITECTURE P.S. © 2021