TAB report44p- Tu.'lqllmu AND I:a SERVICES PORT OF EDMONDS ADMIN BUILDING 471 ADMIRAL WAY EDMONDS, WA 98020 FINAL TAB REPORT R1 OWNER: PORT OF EDMONDS 336 ADMIRAL WAY - EDMONDS, WA 98020 ARCHITECT: JACKSON MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH - SEATTLE, WA 98104 MECHANICAL ENGINEER: COFFMAN ENGINEERS 1101 2ND AVE., SUITE 400 - SEATTLE, WA 98101 MECHANICAL CONTRACTOR: SPEE WEST CONSTRUCTION 307 BELL STREET, #101 - EDMONDS, WA 98020 PROJECT NO: 2230195 DATE: 2/1/2024 (RI) 10/30/2023 (FINAL) TECHNICIAN: ROB COALLIER 02/01 /2024 Page 1 of 32 Adak .mm.► AABC TAC SERVICES, LLC 16929 MAPLEWOOD LANE BOW, WA 98232 PH:(360) 255-5306 FAX:(360) 464-9973 ADMIN@TACSERVICESNW.COM r AABC I UNY i PM AND L-K ti L pvlr. I % TABLE OF CONTENTS DESCRIPTION PAGE COVERPAGE------------------------------------------------------------------------------------------------------------ 1 AABC NATIONAL PERFORMANCE GUARANTY-------------------------------------------------------------------------- 2 TABLE OF CONTENTS•-------------------------------------------------------------------------------------------------- 3 TEST INSTRUMENT CALIBRATION DATES------------------------------------------------------------------------------- 4 PROJECT SUMMARY.---------------------------------------------------------------------------------------------------- 5 LEGEND SHEET •--------------------------------------------------------------------------------------------------------- 6-8 DOAS-1 ----------------------------------------------------------------------------------------------------------------- 9-10 DOAS-2 ----------------------------------------------------------------------------------------------------------------- 11 DUCTLESS FCU'S FCU-01 12 FCU-02 •-------------------------------------------------------------------------------------------------------------- 12 FCU-03 12 FCU-04 •-------------------------------------------------------------------------------------------------------------- 12 FCU-05 •-------------------------------------------------------------------=------------------------------------------ 12 FCU-06 •-------------------------------------------------------------------------------------------------------------- 13 FCU-07 •-------------------------------------------------------------------------------------------------------------- 13 FCU-08 •-------------------------------------------------------------------------------------------------------------- 13 FCU-09 •-------------------------------------------------------------------------------------------------------------- 13 FCU-11 13 FCU-12A •-------------------------------------------------------------------------------------------------------------- 14 FCU-12B •-------------------------------------------------------------------------------------------------------------- 14 FCU-12C •-------------------------------------------------------------------------------------------------------------- 14 DUCTED FCU'S FCU-10 •-------------------------------------------------------------------------------------------------------------- 15 MAU-1 ----------------------------------------------------------------------------------------------------------------- 16-17 SS-01 ----------------------------------------------------------------------------------------------------------------- 18 SS-02 ----------------------------------------------------------------------------------------------------------------- 18 EF-1 •------------------------------------------------------------------------------------------------------------------- 19 EF-2 20 CP-1 21-22 SCHEMATIC DIAGRAMS ------------------------------------------------------------------------------------------------ 23-24 FANCURVES 25-31 PUMP CURVES .--------------------------------------------------------------------------------------------------------- 32 02/01/2024 Page 3 of 32 _..Eyr..rn. AABC YP3fW0 AM) Lk SE:RWIt:I"�: PROJECT SUMMARY 1.0 THE ENVIRONMENTAL SYSTEMS WERE TESTED AND THE RESULTS ARE AS TABULATED ON THE ATTACHED DATA SHEETS 2.0 COMMENTS ON SPECIFIC EQUIPMENT IS INCLUDED UNDER REMARKS SECTION ON INDIVIDUAL DATA FORMS CONTAINED HEREIN, 02/01/2024 Page 5 of 32 4A TESTING AN12 Cm SERVICES AABC FPM FEET PER MINUTE F.S. FLOOR SUPPLY F.S.R FLOOR SUPPLY REGISTER FT. HD FEET OF HEAD FTU FAN TERMINAL UNIT GPM GALLONS PER MINUTE GFH GAS FIRED HEATER HC HEATING COIL HEATER O.L. THERMAL OVERLOAD PROTECTION FOR MOTORS LOCATED AT THE MOTOR STARTER HEPA HIGH EFFICIENCY PARTICULATE AIR H.F. HEPA FILTER HOA HAND/OFF/AUTO SWITCH H.P. HORSEPOWER HPS HIGH PRESSURE STEAM HRC HEAT RECOVERY COIL OR HEAT RECLAIM COIL HVAC HEATING, VENTILATION AND AIR CONDITIONING HWR HOT WATER RETURN OR HEATING WATER RETURN HWS HOT WATER SUPPLY OR HEATING WATER SUPPLY HX HEAT EXCHANGER I.D. INSIDE DIAMETER LAT LEAVING AIR TEMPERATURE L.D. LINEAR SUPPLY DIFFUSER LPS LOW PRESSURE STEAM L.T. LIGHT TROFFER LWG LOW WALL GRILLE LWR LOW WALL RETURN LWT LEAVING WATER TEMPERATURE MAU/MUA MAKE UP AIR UNIT MBH 1,000 BTU'S PER HOUR N.A. NOT ACCESSIBLE N.I. NOT INSTALLED N.T. NOT TAKEN N.V.L NO VALID LOCATION N.Z. NOZZLE O.D. OUTSIDE DIAMETER OPEN NO TERMINAL DEVICE INSTALLED O.S.A. MIN OUTSIDE AIR MINIMUM OAT OUTSIDE AIR TEMPERATURE 02/01 /2024 Page 7 of 32 '%A p-. AABC SERVICES ' ' • PORT OF EDMONDS ADMIN BLDG • • EDMONDS, WA • 2230195 • ROB COALLIER UNIT DATA UNIT ID DOAS-1 (SUPPLY) DOAS-1 (EXHAUST) EQUIP. LOCATION 221 EQUIP PLATFORM 221 EQUIP PLATFORM AREA SERVED BUILDING VENTILATION BUILDING EXHAUST MANUFACTURER SWEGON SWEGON MODEL NUMBER GOLD RX 07 GOLD RX 07 SERIAL NUMBER 10011205773 FAN DATA 10011205773 DESIGN CFM 765 760 ACTUAL CFM 829 737 T.S.P. "W.C. 0.20 0.21 TESTED SPEED 61% 73% STATIC SETTING N./APPL. • •• DATA N./APPL. MANUFACTURER DOMEL DOMEL HORSEPOWER 1.15 KW 1.15 KW NAMEPLATE VOLTS 230 230 TESTED VOLTS 208 208 NAMEPLATE AMPS 3.5 3.5 TESTED AMPS 2.4 2.6 MOTOR RPM 3705 3705 SPEED 0-100% 0-100% PHASE / HZ 1/60 1/60 OVERLOAD SIZE AREA SERVED ARCHIVE 109 NO. 1 THERMAL CODE SIZE CD-1 6" AK F.H. • CFM 40 THERMAL OF FPM CFM DESIGN FPM - 56 140% - CFM 39 OF DESIGNFPM 980/0 OFFICE 6 RM 206 2 CD-1 6" F.H. 35 - 54 154% - 38 1090/0 OFFICE 5 RM 205 3 CD-1 6" F.H. 20 - 45 225% - 33 165% CORRIDOR 4 CD-1 8" F.H. 80 - 180 225% - 82 103% AUDIT RM 211 5 1 CD-1 6" 1 F.H. 20 - 51 1 255% - 21 1 105% OFFICE 4 RM 204 6 CD-1 6" F.H. 20 - 52 260% - 30 150% OFFICE 3 RM 203 7 CD-1 6" F.H. - 20 - 53 265% - 33 165% STORAGE RM 219 8 MESH 6" 0.17 116 20 358 62 309% 307 53 2650/io PG TOTAL 255 553 217% 329 129% SUPPLY BALANCING DAMPERS 2,3,5,6,7,8,9,11,12, 16 & 17: BALANCING DAMPERS FULL SHUT, NO OBJECTIONABLE NOISE OR DRAFTS OBSERVED. FORM: DIRECT DRIVE HRU- HRV- ERV- DOAS LESS THAN 1K CFM TEST DATA 02/01/2024 Page 9 of 32 ITAC.- TI'STINC. SCRvtctS • PORT OF EDMONDS ADMIN BLDG • EDMONDS, WA • 2230195 • ROB COALLIER AABC UNIT DATA UNIT ID DOAS-2 (SUPPLY) DOAS-2 (EXHAUST) EQUIP. LOCATION 221 EQUIP PLATFORM 221 EQUIP PLATFORM AREA SERVED BUILDING VENTILATION BUILDING EXHAUST MANUFACTURER ALDES ALDES MODEL NUMBER Ell00L-Fi-EC-N E1100L-Fi-EC-N SERIAL NUMBER E1100L-Fi-EC-N23020010 FAN DATA E1100L-Fi-EC-N23020010 DESIGN CFM 845 845 ACTUAL CFM 788 778 T.S.P. "W.C. 0.50 0.50 TESTED SPEED HIGH HIGH STATIC SETTING N./APPL. • •• DATA N./APPL. MANUFACTURER ALDES ALDES HORSEPOWER 689 W 689 W NAMEPLATE VOLTS 208 208 TESTED VOLTS 210 210 NAMEPLATE AMPS 6.2 6.2 TESTED AMPS 3.2 3.2 MOTOR RPM 2510 2510 SPEED VARIABLE VARIABLE PHASE / HZ 1/60 1/60 OVERLOAD SIZE AREA SERVED LVL 2 MAINT NO. 1 THERMAL CODE SIZE AK SG-1 12X6 0.39 DESIGN FPM 552 CFM 215 THERMAL INITIAL 0/b • FPM CFM DESIGN 597 233 108% FPM 500 CFM 195 OF DESIGN 910/0 LVL 1 MAINT 2 SG-1 12X6 0.39 539 210 402 157 75% 488 190 910/0 LVL 1 MAINT 3 SG-1 12X6 0.39 539 210 389 152 72% 538 210 1000/0 LVL 1 MAINT 4 SG-1 12X6 0.39 539 210 332 129 62% 497 194 92% SUPPLY 1 845 1 670 1 79% 788 1 93% LVL 2 MAINT El RG-1 12X10 0.69 619 425 436 103% 577 396 93% LVL 1 MAINT E2 RG-1 12X10 0.69 612 420273 fl397 65% 556 382 91%EXHAUST 845708 84% 778 92% FANS PROGRAMMED TO HIGHEST SPEEDS AVAILABLE. FORM: DIRECT DRIVE HRU- HRV- ERV- DOAS LESS THAN 1K CFM TEST DATA i 02/01/2024 Page 11 of 32 TE ING ANn E:a RERVIC $: FCU-06, 07, 08, 09, 11 OFFICES 203, 204, 205, 206, BREAK ROOM 216 AOL AABC UNIT ID FCU-06 FCU-07 FCU-08 FCU-09 FCU-11 EQUIP. LOCATION CEILING CEILING CEILING CEILING CEILING AREA SERVED OFFICE 203 OFFICE 204 OFFICE 205 OFFICE 206 BREAK ROOM 216 MANUFACTURER MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI MODEL NUMBER TPLFYPO12FM140A TPLFYPO12FMI40A TPLFYPO12FMI40A TPLFYPO18EM141B TPLFYP030EM140B SERIAL NUMBER DESIGN CFM 38M0186665TKB7 240-280-335 38M0186965TKB7 FAN DATA 240-280-335 38M0187065TKB7 240-280-335 38M0035565TLAH 636-671-742-812 38M0069165TLAK 636-671-742-812 ACTUAL CFM 240-280-335 240-280-335 240-280-335 636-671-742-812 636-671-742-812 TESTED SPEED MANUFACTURER HIGH MITSUBISHI HIGH • •• MITSUBISHI HIGH DATA MITSUBISHI HIGH MITSUBISHI HIGH MITSUBISHI HORSE POWER 50 W 50 W 50 W 120 W 120 W NAMEPLATE VOLTS 208-230 208-230 208-230 208-230 208-230 NAMEPLATE AMPS 0.23 0.23 0.23 0.43 0.43 SERVICE FACTOR 1.00 1.00 1.00 1.00 1.00 MOTOR RPM VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE SPEED 3 SPEED 3 SPEED 3 SPEED 4 SPEED 4 SPEED PHASE / HZ 1/60 1/60 1/60 1/60 1/60 OVERLOAD RATING THERMAL AREA SERVED NO. CODE SIZE THERMAL THERMAL THERMAL THERMAL AK DESIGN INITIAL 0/b OF OF DESIGNFPM CFM FPM CFM DUCTLESS FORM: FCU & AC- NO OSA- DUCTLESS- DIRECT DRIVE- TEST DATA 02/01/2024 Page 13 of 32 lamb, TE AABC MRVIK ES ' ' • PORT OF EDMONDS ADMIN BLDG • • EDMONDS, WA " • • 2230195 • ROB COALLIER FCU-10 • 209 ARCHIVE ROOM I UNIT ID FCU-10 UNIT DATA EQUIP. LOCATION CEILING AREA SERVED ARCHIVE MANUFACTURER MITSUBISHI MODEL # TPEFYPO15MH142A SERIAL # DESIGN CFM 37WO03987GEHAl 494 FAN DATA ACTUAL CFM 508 ESP 1.00 TESTED SPEED HIGH TESTED SETTING MANUFACTURER N./APPL. MITSUBISHI MOTOR DATA HORSE POWER 0.09 KW VOLTS 208-230 AMPS 1.2 SERVICE FACTOR 1.00 MOTOR RPM VARIABLE SPEED 3 SPEED PHASE / HZ 1/60 HEATER SIZE THERMAL SERVEDAREA NO. CODE ARCHIVE RM 1 CD-2 10" DESIGN• OF FPM CFM FPM CFM DESIGN FPM CFM DESIGN F.H. 260 262 1010/0 257 990/0 AUDIT RM 2 CD-2 6" F.H. 110 133 121% 113 103% CORRIDOR 3 CD-2 8" F.H. 140 116 83% 138 990/0 SUPPLY 510 511 1000/0 508 1000/0 CORRIDOR R1 RG-2 22X22 1.12 455 510 456 511 100% 453 5011 1000/o RETURN 510 511 1000/0 508 100% FORM: FCU- VRF DUCTED- NO OSA- NO VAV- DIRECT DRIVE- TEST DATA 02/01 /2024 Page 15 of 32 qm TESTING AN SERVICE PROJECT: LOCATION: PROJECT NO: CONTACT: SYSTEM: AREA SERVED: AREA SERVE❑ NO. CODE SIZE AK DESIGN INITIAL Oho OF FINAL Oho OF FPM CFM FPM CFM DESIGN FPM CFM DESIGN REMARKS: �.Y TE A PC. AABC s RVmEs • ' • PORT OF EDMONDS ADMIN BLDG • • EDMONDS, WA ••• 2230195 • ROB COALLIER UNIT ID EF-1 UNIT DATA EQUIP. LOCATION CEILING AREA SERVED ELEC ROOM MANUFACTURER GREENHECK MODEL NUMBER SQ-70-VG-X SERIAL NUMBER DESIGN CFM 21808941 150 FAN DATA ACTUAL CFM 158 T.S.P. "W.C. 0.25 DESIGN FAN RPM 1437 TESTED FAN RPM MANUFACTURER 970 VARI-GREEN • •• DATA HORSEPOWER 1/15 VOLTS 115 AMPS 1.3 SERVICE FACTOR 1.00 MOTOR RPM 1725 SPEED 2-10 VDC PHASE / HZ 1/60 OVERLOAD SIZE THERMAL SPEED SETTING 4.7 VDC AREA SERVED NO. CODE SIZE ELEC ROOM E1 EG 1OX10 AK • OF OF FPM CFM FPM CFM DESIGN FPM CFM DESIGN F. H. 150 317 211% 156 1050/0 EF-1 150 317 211% 156 1050/0 FORM: DIRECT DRIVE TEST DATA >2000 CFM 02/01/2024 Page 19 of 32 !It! kAW Cx SERVICES • • + PORT OF EDMONDS ADMIN BLDG • EDMONDS, WA •'• • 2230195 • ROB COALLIER CP-1 HOT WATER RECIRC PUMP DATA PUMP NO LOCATION '•• AREA SERVED HOT MANUFACTURER • MODEL NO. .1 SERIAL NO. 1.1 IMPELLER • TEST DATA DESIGN • 1 ACTUAL DISCHARGE •••• •• SUCTION " • DELTA AMk AABC TEST DATA 1 DESIGN ACTUAL DISCHARGE SUCTION DELTA BLOCK OFF BLOCK OFF DISCHARGE • • • • • • mmo DISCHARGE SUCTION PROVIDED SUCTION DELTA _®-®i DELTA MOTOR DATA MANUFACTURER • • HORSEPOWER RPM 1 FRAME • SERVICE FACTOR PHASE / HZ .1 OVERLOAD SIZE ' AMPERAGE 1.01 1 VOLTAGE 120 MOTOR DATA MANUFACTURER HORSEPOWER RPM FRAME SERVICE FACTOR PHASE / HZ OVERLOAD SIZE AMPERAGE VOLTAGE UNABLE TO TEST PRESSURE AT PUMP, NO PORTS OR GAUGES PROVIDED; ACTUAL VALUES PROVIDED ARE FROM PUMP DISPLAY. PUMP SET TO CONSTANT FLOW @4.8 GPM (LOWEST GPM SETTING) FORM: PUMP TEST DATA SHEET 02/01/2024 Page 21 of 32 3 4 1�36x 14 INTAKE LOUVER 35x14 INTAKE LOUVER ,® 24.14 EXHAUST FOR FUTURE T. SIZING RASED ON 45% FREE FOR FUTURE n. SIZING LOUVER FOR FUTURE BASED ON 45% FREE n. SIZING BASED ON ' AREA SPUT AREA 457. FREE AREAFUTURE 5Y51EM ZONE ___. — ..._.__.___�.............. .1._...1L _ _ ----------------------------- ' _._..... . _J- = .�..-- cI _ - -. - ---- - LWO j 9�::>24x14 EXHA1Sr LOUVER FOR FUTURE ----�----'—'�--- 1 -`J 1 n. SIZING BASED ONE 45x FREE AREA UNIT HEATERS FOR FREEZE PROTECTION I EH-4 f �t ❑ COMMERCIAL I m 1 -_- RFTAIl - 1K" (RETAIL FIRE_ RISER I _ I I I SHEET NOTES: (5 ' 11 ACKSON � MAID RCHITE�CTURI ©2414 EXHAUST LOUVER FOR FUTURE n. SIZING BASED ON 45% FREE AREA� LS I; ✓ 36x14 INTAKE LOUVER 'I^•,FOR FUTURE n. SIZING IBASED ON 45% FREE (n 0 HATER WITH FlRE IrttSE'R •,MF- LOB Y IOCAIiON' •.I _._. 1. ^'...ri 1L- ----- ----'^ -- -- - - -- - -- -- J -:. ---- SPRINKLER EOUI ENT ... - .... III 1 VRF $ DOAS ZONE DDAS ONLY ZON I; 7^ • '��"" I OTTON D<� EXHAl15i GRILLE___--a�u.iv�; /;a tl SHALL BE 24' -'� •.- FCU-02 1 ,'55=01 •. el .raE—A801E-iNE-R00R_. __ _:_ 14'0E1 U� _OI 20 CFMCD --- €� _ _ _ _ _ 4dr 1 ART9.DAGE , I• �."".'-"�' II INDOADUAL SPLIT YRF $ DCNS LO li' 1 �y� I fix't{I' 1 SS-OT SYSTEM ZONE I,. I: ZONE 7 -T'-_ � 11 WAIL MOUNTED : �. 12-VEAL U GRILLE 6 _.._ S ,6 �.. `�.r_L I •. a..� FUTURE RETAIL CU I' E EV FUTURE RETAIL CU .. - _ _ _ . 10•. E _ZS. I .._T.II _._._" ART'�CAGE II ACHINE RtA, i FM- N 4 — — — — — 6- I , (WALL MOUNTED I; W SA CF1II FUTURE RETAIL ...... . ------ ON GROUND o I12-'SA UP' - I UNISEX R N ANGLE gFFUSEA 10712.0EA ON :0-a 16E� i� 55-01 OUTDOOR BLADES DOWN '� j� 14.0EA BOTTOM OF 60 '_J �I�UNIT (WALL I !TOWARDS FLOOR ,12x10 R, T12x10 EXHAUST4: o i 6- MOUNTED): RAND TOWARDS THE 12=s FG_L GRILLE SHALL u L ICI SS-02 OUTDOOR DOUBLE HT I IDOOR 12x6� r 420 CFN -a $y_1 490 CFM 24' �� :UNR (WAIL MAINTENANCE 1DOL'BLE HT SG -I 8 f0 CFII 12sU THE FLOOR R� 6_1 !11' MOUNTED BELOW); DAY f21 1 F INTENA.NCE .210 CF1A V 12z6 �=01i0.4-J. - fFM o;.: FUTURE RETAIL CLI BAY(21 -1 12.10 I- SWCC'4AN .II... ... , ON GROUND � I 12.0RA 1 ) I' IVTEVARCE (1 ' • Y • i:i ji 210 CM SHOP 490 490 CFM oIrx.�WCF_2 ANGLE. DIFFUSER *..-1-. �. + '�n BLADES DOWN I! I _ �„ D III: I LUSTODIAI TOWARDS FLOORTIE AN, ® -3 ®s I CUSIOOtAt R.I . STORAGE BOUNDS '^• I I EH=1' OR STORAGE I ; --.- OiHERS TO 'I 1 H-1 (TYP. fi '.-i VT7ti1 PROTECT MECHAIICAL�o :' r} EOUIPNENi. O 'y L—----- ---'.` — —•— — — — —'— _-:.y '""------ ..------..—.—. — - -- - --JAL- --`--`J IJ t .-...._ } !; ---..........----;i." --- - - - ' �- HARNG ------- VENnUIION COORDINATE HEATER COORON4IE HATER ONLY ZONE LOCATIONS WITH LIGHnNG - LOCATION WITH SHELVING IN -.... AND ROLLUP DOORS (T9) ROOM ®LEVEL 1 HVAC PLAN SLxD Il14' . I— Z O N N } p� w3a Lu LL ogo O Q z<0 W o C ' d 0 w J) Z O? N rn Lu 03< LL coQ ¢ 0 O KEYNOTES: z W O O O w�I.I wlof°Ru�.�u�N I'NOR�, EawliD,r �rM � .o awExu+c su mm r lOq Na EEE9KA a Q a e w RIW I�WI. /[nNL M�ArIbD 11K x0i YET HDI PEpA�xc IDuf 5m[II MA © RmvE m uo IR mswa RmAL A Hover ncm.pom er MwuFxnuxn wocE xxuaE oweaaE mIw ro ravel ax FT-x xo xxl-I. mrtu voewuxr VFCL fOV THE IlxxlY O.£RmC Sx1O1 E7 ? - o © Rc NL LW Wla NS 41PM1 tOR C9p✓DINAgI P)PO95 04.Y (RAUIQ. o � � �wAm1 xouxlm vRol1 muxc/s1AE¢mEW xXxE nx emroll a IAcr © NpAE RD➢ vaLWID MAI IP 07 rAw VAv MIOEM4AM Ml IIOIHRO oXmooc EMrs ro I® aoRas um nAll mArm¢ w ,� un RUKr. R � - r rE. xn.0 mxc xw rtn wmrx:IWans REauan DFMUNRS. Iwliw�a w'IQS Y i1[xl C011nc, ai m -S F 3 e a t- q�i oasTmATwra. uo v' ma .xL oxlaxxNm F.x laumrs wIx cvcE aIw m aa. slminuai mwwc. lama. uo RwINa Dove a aoEx. vmr a vAr aAOEs .D a rAffrnY uxoDelcvll it ni Dove. Il.ww acwx+a Ixuasu en.EVI rav u- r.x aea xo wu ur ouoR STiO N '•Av 'ems. *' stir Dimensions DDAS-Z_ FRONT VIEW Recirculation Port (optional) 1-5/8" 8" (41 mm) (203 mm) 1 36-1/4" mm) If m mm) ) A Anchor 41-3/4" — (1060 mm) i SIDE VIEW I '�I q• ,nsre. 20' (102 mm) 1346 mm1 m. mm 39-7/16' (1002 mm) 47-1/4' (1200 mm) Performance E1100L-Fi-EC-N 1,80 Ventilation Performance I 1,40 1.20 I I Qj N r- I yl 0,80 CL v a,6a iI BOTTOM VIEW 1331 mm1 (437 mm) 1 High speed (Max) 653W 2 Med speed (Max) 412W 3 Low speed (Max) 271 W 4 Reduced med speed 152W 5 Reduced low speed 94W N — �— V1 OAO 5 E 0,20 N .. X 0.00 W 300 400 600 600 700 800 900 1000 ,100 1200 1300 Airflow CFM *AT 230V I Project: Architect: Location: Engineer: Model #: Quantity: Contractor: Comments: Submitted By: Date: Controls 0-10 VDC inputs (for supply and exhaust) or multiple fixed speed options Low -voltage dry contact (24 VAC, 20 VA) for: Occupancy Control (On/Off) Interlock contacts Optional Recirculation Mode 24 VAC, 10 VA output for supply and exhaust dampers (by others) Compatible with: Digital Multifunction Control (P/N 611242-FC) LCD Electronic Multifunction Con- trol (P/N 611227) ao 00 20/40/60 Minute Timer (P/N 611228) Speed Control (Low/Intermittent/High) (P/N 611229) Mode Control (exchange or recirculation) (P/N 611230) BACnetT"' interface (P/N 611235) E1100L-Fi-EC-N Core Efficiency 5% 65% �neree E,e W. ssx xmroie V45% v_x er.34,a U 35% — — — 2s% --- --- - _Era.3orai 15% — 8 Airflow CFM AHRI core Ref k 10346213 For more information, contact your Aldes sales advisor, visit ales-na.com, call 1.800.255.7749, or find us on 0000 E1100L-Ei-EC-N_Spec_ENG_0121. 02021 American ALOES Ventilation Corporation and ALOES Canada. All Rights Reserved. Reproduction or distribution, in whole or in part, of this document, In any form or by any means, without the express written consent of American ALOES Ventilation Corporation and/or ALW.&AJ(hQA4ictly prohibited. The information contained within this document is subject to change without prior written notice. Page 25 of 32 `k EF-1 LNGREENHECK Printed Date: 10/21 /2022 Job: Port of Edmonds Admin & Maintenance Bldg Building Value in Air. Mark: EF-1 Model: SO-70-VG MA 0.5 a, 0.4 0.3 a� L 0.2 U) 0.1 mie SQ-70-VG Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume SP (in. wg) RPM Power (hp) (CFM) (CFM) 150 150 0.25 1437 1 0.02 ".'43 RpM p---- Max--`--- ----------- ------------ ------------ ------------- ---------- 0 +R W--------------- 0 50 100 150 200 Volume (CFM) 0 Operating Bhp point O Operating point at Total External SP Construction Limit Fan curve Min FRPM - - - - System curve ------- Brake horsepower curve 250 300 0.30 0.25 0.20 0.15 0 a a) 0.10 m 0.05 0.00 350 \\orca\Public\Stephen\winjobs\Port of Edmonds Admin & Maintenance Bldg.gfcj CAPS 4.39.1057 Generated �ql 4i z dorse.com Page 8 of 16 age 27 of 32 AHU Design ERV-1 Fan diagram SUPPLY Project: Port of Edmunds Unit name: ERV-1 - Indoor horizontal - Design data Design data, Supply air 5 in. VIC 4 3 2 fml 0.8 0.7 0.6 0.5 0.4 fiviegm/ Date:15/07/2022 28 / 1.0.20220701.1111111 Unit ID: AD-10001196589 The chart shows the static pressure rise of the fan in Pa relative air flow in m3/s and in m'/h at different relative speeds (minimum speed = 0% and maximum speed = 100 %). One can also read electrical power from mains in kW and sound power level at fan outlet in dB. Green area: Recommended working range for sizing Blue area: Permissible operating range for low airflow in demand controlled ventilation systems (VAV) with pressure control. Max operating point: Red circle with a vertical line Design operating point: Green circle with a cross Clean operating point: Blue circle with a horizontal line Fan of type GOLD Wing+ Fan size: 7 Direct drive with speed controlled EC motor Min speed: Max speed: Speed 500 3700 rpm Rated motor power/motor 1.54 hp 0910112024 --- Page 29 of 32 7 (18) LlfGREENHECK Printed Date: 07/13/2022 Job: Port of Edmonds Admin & Maintenance Bldg Building Value in Air. MAU_1 Mark: MAU-1 (1) Model: MSX-P109-H12-MF Fan Charts And Performance Supply Total Volume External SP Total SP RPM Operating Motor Fan Size (CFM) (in. wg) (in. wg) Power (hp) Qty Qty Type Drive -Type 1,965 1 1.201 3377 0.85 1 1 1 1 1 Mixed Flow I Direct Sound Performance in Accordancia with AMCA Sound Power by Octave Band Lwa dBA Sones 62.5 1 125 1 250 1 500 1 1000 1 2000 1 4000 1 8000 82 1 71 1 71 1 75 1 78 1 80 1 80 1 73 85 1 74 1 23 Supply Fan 3.5 3.0 i 3377,2 2.5 rn 3 2.0 d a 1.5 1.0 0 0.5 00 0 5 10 15 20 Volume (CFM) x 100 Z_� Operating Bhp point 0 Operating point at Total External TP Fan curve ...... System curve ------ Brake horsepower curve 1.4 1.2 1.0 0.8 r a� 3 0.60 a� m 0.4 m` 0.2 0.0 25 Z:\Chad\winjobs\Port of Edmonds Admin & Maintenance Bldg.gfcj CAPS 4.38.1089 Generate(Pgp'VR986@dorse.com Page 3 of 14 Page 31 of 32