Loading...
ENG2024-0014 ROW PERMITOF WAY EUC PERMIT PERMIT NUMBER City of Edmonds EdmondsRIGHT 98020 ENG2024-0014 LM www.edmondswa.gov i Description: COMCAST - OVERLASH 260' RISER DOWN & UG TO PRIVATE PROPERTY ISSUED: 02/13/2024 Address: 21701 76TH AVE W EDMONDS WA 98026-7536 EXPIRES: 08/13/2024 Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00580700002702 NAME TYPE NAME ADDRESS PHONE APPLICANT JESSAMIN SANTOS 1701 JOHN F KENNEDY BLVD, PHILADELPHIA PA 19108 (206)401-2188 CONTACT CABLECOM LLC 1429 AVENUE D 339, SNOHOMISH WA 98291 (360)670-4291 CONTRACTOR CABLECOM LLC 19910 NORTHCREEK PARKWAY N, BOTHHELL WA 98011 (363)608-6700 OWNER HR ACQUISITION I CORPORATION PO BOX 92129, SOUTH LAKE TX 76092 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE - PER PERMIT $45.00 $45.00 ENG - INSPECTIONS $504.00 $504.00 RIGHT-OF-WAY PERMIT - STANDARD $378.00 $378.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. RELEASED BY: MAJ DATE: 02/13/2024 Printed: Tuesday, February 13, 2024 11:57:06 AM 1 of 2 RIGHT OF WAY EUC PERMIT PERMIT NUM11BE City of Edmonds www.edmondswa.gov • • CONDITIONS CONDITION TYPE ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND AND NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT COMPLETE A-1 JOB START E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL** E-7 CONCRETE SIDEWALK E-7 RESTOR LIMITS Printed: Tuesday, February 13, 2024 11:57:06 AM 2 of 2 RECEIVED pin INC. iago SECTION A RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal Requirements outlined in Right-of-Wgy permit Handout E6�. Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A" instead of leaving blank. All fields required. Incomplete Applications will be denied. General Info Project Name COMCAST - JB0001335034 Site Address or if no site address use Property Address at NW corner of project area: 21701 76TH AVE W EDMONDS WA 98026 Associated Permits: BLD PLN ENG Owner and Entity Holding Franchise (if applicable) Name of CompanyCOMCAST CABLE HOLDING Franchise Ordinance No: Point of Contact J ESSAM I N SANTOS Title PERMIT COORDINATOR Address 1701 JOHN F KENNEDY BLVD City PHILADELPHIA State PA Zip 19108 Phone 206-401-2188 Emai1WACONSTRUCTION JOINTUSE@COMCAST.COM Contractor and Authorized Agent of •wner (see note •- •w) Name of Company CABLECOM LLC Contractor ContactsDuring Construction Primary Name CABLECOM LLC - MIKE FINCH Agent NameLEAH IHLENFELDT Title CONSTRUCTION SUPERVISOR Title PERMIT SUPERVISOR Mobile360-965-5085 Address 1323 AVENUE D #339 Email MICHAEL.FINCH@CABLECOMLLC.NET CitySNOHOMISH State WA ZiP98290 Secondary Name Phone 360-670-4291 Title Email SNOHOMISH.PERM ITTING@CABLECOMLLC. NET Mobile City of Edmonds Business License No: N R-021818 Email State License No: CABLEL`971 DP V Contractor verifies it is currently bonded 16 Contractor verifies it currently has general liability insurance NOTE: ECDC18.6o.o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as well) ❑ Traffic Control Only (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 \-� Utility Franchise Work (no associated development) Project Description Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF x LF SF Alley 72 hours + LF x LF SF Parking 72 hours + LF JxJ LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTIONC. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications d cable ❑ power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existin overhead infrastructure in the area of work? Yes No 2. Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)? If yes, describe: RISER PLACED NEAR POLE 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility system? 5. Does the work involve proposed additions to an aboveground utility system? If es: Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Details of Work to be Completed Yes No 6. 1Does your project involve rebuilding or replacing utility equipment which currently serves more X than one lot or commercial development? City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 If yes, answer the following questions related to project area, i.e. the actual area in which the project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? I I How many are to be added? 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additionalpoles to be laced? How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: How many? I I What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: r DATE: 1/8i2024 APPLICANT PRINTED NAME: LENAIZA ENRIQUEZ APPLICANT TITLE: PERMIT COORDINATOR NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 ROUTE OVERVIEW Completed By: LEN ENRIQUEZ Address: 21701 76TH AVE W EDMONDS WA98026 Completion Date: 1/8/2024 Right of Way Footages: Job Type: Select New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 0 New Aerial Fiber: 0 Overlash Fiber: 0 Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: No Job Subtype: Select Survey Scope: Post -Sale Project Manager: Select Source System: JB0001335034 Legend Provide Clear Right of Way Construction Details TIE IN AT OVER LASH 3 POLES 2 SPANS 260'. PLACE NEW COMCAST (1)-2" RISER AND CATV CABLE DOWN POLE. BORE PLACING NEW COMCAST (1)-2" CONDUIT AND CATV CABLE. CONTINUE BORE IN PRIVATE PROPERTY. ALL CONSTRUCTION AND RESTORATION TO MEET OR EXCEED CITY OF EDMONDS STANDARDS. RECEIVED New Ped 08 2024 NEW PS � SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM .tan CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Existing U/G CONSTRUCTION NOTES-- Existing Aerial i 7603 218TH ST SW I Pq�g0pr�0000300 ° 2171278THAVE W PARCELi I I 9 + \ I + ) PLACENEWCOMCASTn}rN=ANOCATVCABLE 21705 70TH AVE W NO Do"" POLE' Pam* p p v A � I g I 0RE LOPLACING NEW COMCASTM-2-CONDOTAND CATV CABIi — — — — - a New U/G I I I I CONTINUE WIRE IN PRIVATE PROPOnV. x I f I0 J1 �+ New Aerial o ° 8 I I � ~ I Interior Path POTHOLE UTILITY CROSSING PRI0R TO BOREMILENCH ®MWAN NOW" VERIrCALCLEARANCE rRCM — R W R/W R/W Y R W R/W /yr D7STN6URITIESATTHECROSSING Exterior Building Path -SEW SEW SEW SEW SEW SD SD SD so SO sD SEW SEW SO so �J— Eve` Footage Break RESTORATION NOTES RMORECONCItETE PANEL PER CNO: EDMONDSEDMONDSSTAND STANDARDS. Fiber Splice Point 76TH AVE W - i Storage LoopCD _ � — —W -W W Riser ® Pti" NUI R VI254363 ® 1 Pole -T-T— T T_ T T 4.T 2 +a A Lock Box R/W R/W R/W /W o R/W -R/'/, R/V! Footage 3 PAR 10EL# 70 80700OOVE a2702 Text_ r PARCEU1005B07ODD2 D7D1 �I °J- Text Box Callout Arrow A RESTORATION LIMITS TO BE DETERMINED New Tap BY CITY ENGINEERING INSPECTOR OWNER/CONTRACTOR IS RESPONSIBLE FOR ❑1 EROSION CONTROL AND DRAINAGE Phase Identifier Power Suppy Applicant shall repair/replace all ENGINEERING DIVISION r - ' "JLL E E I LE F E F.I E 7. ll E- E L -ll I E 1 OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING damage to utilities or frontage improvements in City right-of-way p Y g Y E I" F -LL E I II nUnE WIRE H APPROVED AS NOTED 11E EE.i THE H r 'r�L . R E n -L inE-n I I r n nUrE - E I. U E Hard Surface Cut ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY per city standards that is caused or occurs during the permitted project. " U I E n _E _ e If E je (�0✓. �i,hn2 02/08/2024 UTILITIES MAY REQUIRE A SEPERATE PERMIT. y 6,1R0: GGIUR:1`OOS tO m01O tOCJ1*,OfL Avg 7r OA[M}A}9R J:t Jttt I! l a Zit n,OtOUf/Jt 1 ROUTE OVERVIEW Completed By: LEN ENRIQUEZ Address: 21701 76TH AVE W EDMONDS WA 98026 Completion Date: 1/8/2024 Right of Way Footages: Job Type: Select New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 0 New Aerial Fiber: 0 Overlash Fiber: 0 Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: No Job Subtype: Select Survey Scope: Post -Sale Project Manager: Select Source System: JB0001335034 Legend Provide Clear Right of Way Construction Details TIE IN AT OVER LASH 3 POLES 2 SPANS 260'. PLACE NEW COMCAST (1)-2" RISER AND CATV CABLE DOWN POLE. BORE PLACING NEW COMCAST (1)-2" CON DU IT AND CATV CABLE. CONTINUE BORE IN PRIVATE PROPERTY. ALL CONSTRUCTION AND RESTORATION TO MEET OR EXCEED CITY OF EDMONDS STANDARDS. RECEIVED New Ped Jan 08 2024 N NEW PS CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Existing U/G Existing Aerial New U/G New Aerial ';+ �, '- COP",AF �.�� _•:. Interior Path ..:ILI Exterior Building Path -1 i ;� ': _� ems•- 'i4• II !-,, I o � _r. Footage Break Fiber Splice Point ' Storage Loop • i°' .C' , �_ G f= ` Riser Pole • -�:• L, Lock Box _ —, Footage • �, r '�+• ' s;,�` ��� � , ' M � � •'� --� - ... _ _ _ - »�.� Text Box Text Callout Arrow 1 ]� New Tap Phase Identifier 2 t t PS > sj; • - s t SqW Power Suppy r Hard Surface Cut 1 ROUTE OVERVIEW Completed By: LEN ENRIQUEZ Address: 21701 76TH AVE W EDMONDS WA98026 Completion Date: 1/8/2024 Right of Way Footages: Job Type: Select New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 0 New Aerial Fiber: 0 Overlash Fiber: 0 Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: No Job Subtype: Select Survey Scope: Post -Sale Project Manager: Select Source System: JB0001335034 Legend Provide Clear Right of Way Construction Details TIE IN AT OVER LASH 3 POLES 2 SPANS 260'. PLACE NEW COMCAST (1)-2" RISER AND CATV CABLE DOWN POLE. BORE PLACING NEW COMCAST (1)-2" CON DU IT AND CATV CABLE. CONTINUE BORE IN PRIVATE PROPERTY. ALL CONSTRUCTION AND RESTORATION TO MEET OR EXCEED CITY OF EDMONDS STANDARDS. RECEIVED New Ped Jan 08 2024 NEW PS N CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Existing U/G TrF IN SP0554•WA1 Y. i Existing Aerial New U/G New Aerial% f Interior Path Exterior Building Path Footage Break �- - Fiber Splice Point �' �► j - 1 Storage Loop R O Riser ,. Pole .:�. �.- _-- _ - .' r • ;�; ^ Lock Box Footage - _- - Text Text Box _ f Callout Arrow New Tap ❑1 , 176' Phase Identifier Power SuppY - J•.= Hard Surface Cut ROUTE OVERVIEW Completed By: LEN ENRIQUEZ Address: 21701 76TH AVE W EDMONDS WA98026 Completion Date: 1/8/2024 Right of Way Footages: Job Type: Select New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 0 New Aerial Fiber: 0 Overlash Fiber: 0 Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: No Job Subtype: Select Survey Scope: Post -Sale Project Manager: Select Source System: JB0001335034 Legend Provide Clear Right of Way Construction Details TIE IN AT OVER LASH 3 POLES 2 SPANS 260'. PLACE NEW COMCAST (1)-2" RISER AND CATV CABLE DOWN POLE. BORE PLACING NEW COMCAST (1)-2" CONDUIT AND CATV CABLE. CONTINUE BORE RECEIVED IN PRIVATE PROPERTY. ALL CONSTRUCTION AND RESTORATION TO MEET OR EXCEED CITY OF EDMONDS STANDARDS. New Ped Jan 08 2024 NEW PS N CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Existing U/G 1/2- FULL DEPTH 10 Existing Aerial EXPANSE JDUUMNMY New U/G • a n New Aerial • ° PHOTO *1: FACING (S) ON THE (E) SIDE OF 76TH AVE W. Interior Path 10' O.C. s D.C. Exterior Building Path + PLAN VIEW . r Footage Break / (NOT TO SCALE) -:,LE 4UTANE4 5' MIN MIN. 6 3 Fiber Splice Point 2>< MAX coLL DEPTH 1/2" EXPANSIONCUR SEE CO STIDTER JOINT MATERIAL SEE COE STD 2x MAX Storage Loop Vim./ OTL TR-520 ? \� T. IiF 1/2" R 4 • d 1/2 R A� 4,4* ® • • • e d Riser l ® rt o 1 Pole 2" MIN 5/8" MINUS CSTC ON SEE NOTES 4 & S ♦f_vz u. taw .•. ........ r. NATNE SUBGRADE BEARING SOIL SEE NOTE 9 Lock Box NOTES• (NOT TO SCALE) •� --- �1/8- TO 1/4- u , ^` - 1. CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. i _ _ Footage 2. CONCRETE SHALL BE CLASS 3000/COMMERCIAL MIX. 1./2 IR Text 3. FINISH SHALL BE LIGHT BROOM. - Text Box — DUMMY JOINT 4. SIDEWALK THICKNESS SHALL BE 4". (NOT TO SCALE) 2 5. SIDEWALK THICKNESS AT DRIVEWAYS AND DRIVEWAY TRANSITIONS SHALL BE 6. Callout Arrow • 6. CURB AND GUTTER SHALL BE PDURED SEPARATELY FROM SIDEWALK. 7. LIDS FOR JUNCTION BOXES AND UTILITY VAULTS SHALL BE NON-SKID AS SPECIFIED BY ENGINEER. New Tap 8. SEE COE STD DTL TR-550 FOR POSSIBLE ROOT BARRIER INSTALLATION. �1 9. NATNE SUBGRADE BEARING SOIL AND CSTC SHALL BE COMPACTED TO 95% MAXIMUM DENSITY. Phase Identifier 10. ALL EDGES AND JOINTS SHALL HAVE 1/2" RADIUS Power Suppy -� REVISION DATE APRIL 2021 • CITY OF EDMONDS CONCRETE SIDEWALK STANDARD PUBLIC WORKS Hard Surface Cut DEPARTMENT DETAIL FS ta9� TR-531 APPROVED BY. R. ENGLM ROUTE OVERVIEW Completed By: LEN ENRIQUEZ Address: 21701 76TH AVE W EDMONDS WA 98026 Completion Date: 1/8/2024 Right of Way Footages: Job Type: Select New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 0 New Aerial Fiber: 0 Overlash Fiber: 0 Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: No Job Subtype: Select Survey Scope: Post -Sale Project Manager: Select Source System: JB0001335034 Legend Provide Clear Right of Way Construction Details TIE IN AT OVER LASH 3 POLES 2 SPANS 260'. PLACE NEW COMCAST (1)-2" RISER AND CATV CABLE DOWN POLE. BORE PLACING NEW COMCAST (1)-2" CON DU IT AND CATV CABLE. CONTINUE BORE RECEIVED IN PRIVATE PROPERTY. ALL CONSTRUCTION AND RESTORATION TO MEET OR EXCEED CITY OF EDMONDS STANDARDS. New Ped NJan 08 2024 NEW PS CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Existing U/G Existing Aerial New U/G New Aerial Interior Path Exterior Building Path Footage Break Fiber Splice Point Storage Loop Riser Pole Lock Box Footage Text Box Callout Arrow New Tap Phase Identifier Power Suppy Hard Surface Cut 150' Text ❑1 Ps CATCH RASINANLEI l RRE HYDRANi WATER/CxS VALVE J�LIGHT Posy STFFEr Slav ADA RAW �-/ H HE :E u T=EE TEE STJVF 0 TllLE - Eln 0 Taff LE- E ® RISER - EXISTING ® RISER - PROPOSED PCLE ANCHOR/DD6'4 GJY - EXISTING POLE ANCHOR/D'JM1 GJY - PROPOSES. PcL,E ANCHOR/DOav GJY - EXISTING Q0Q` AERRL STOPAWE - EXISTING O0O AERk STOWE - PROPOSED U E 'OINI - EXSSING U E 'ONI - PROPOSED UTLITY VAULT - EXMG a ,SIZE MAY VARY) f� JlUIY VAJLT - PROPOSED f I IZE MAY VARY) :nm PEDESTAL - oumc �j (SZE MAY VARY) _R P PCESTAL - PROPOSED O ;:1_E PAX, VARY) LNDERGRCLQ STORAGE - EXISTING OE T - E - 7`Qt ®j nUr TH LE E T E H- E ® I E - LEGEND � 1 T E T -71 u irr, I JiuTY cG nwB TUT- ENDS X 7,JCT104 40TE;/RESTO4104 CAUDUT (X) 'H310 LOCATION/OWNTATION CALLCUT (X)(X') JIVE49ONS F;\OV FRS'�IOUS PAGE I REWNING WALL \1 NORTH ARRCW ell HATCH PATTERNS d Lip a ° ° COhCI+'ETE SUEWALK ORA.& BRER/COBBLE _ = WATER BODY LINETYPES A 4FVL FI-ER - EXISTLnG A AMAL R !ER - PROPOSED --- -- --- CCa; IT - ExI$W — - - - - - - — CCtN.l_ Ir - PROPOSED — - - - - E'IE-' U',E/JSnCN UNE R/W 1 HT F WAY — — EL PMNDARY SEw IT- E E 'SO T - -1 w -TE STV TE- E ELETI F/0- A E n T— TELE H E juK— I nUT X , - FE E F Jl TABLES ,*F I T E E n-L 1 T CALLOUT ;;F E E n-L I T-IL -LLOJT T-1L. y� TAL SM).E n-L T-IL _T C4WJT !F� OUT: o TITLE N/A ..TIUTY I 0'-0" .TILIT' 0'-0" TILFT LE INFORVATICN TAELE (%_•t.:E J ATTACHMENTS VAY VARY) 1 AS B U I LT COVER Completed By: LEN ENRIQUEZ N `E s Completion Date: 1/8/2024 Address: 21701 76TH AVE W EDMONDS WA 98026 Job Type: Select Job Subtype: Select Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages are summarized on Survey Rollup tab. Survey Scope: Post -Sale Project Manager: Are Additional Pages Needed: No Select Source System: JB0001335034 Legend Provide Clear Route Overview Construction Details New Ped ❑ RECEIVED TIE IN AT OVER LASH 3 POLES 2 SPANS 260'. PLACE NEW COMCAST (1)-2" RISER AND CATV CABLE DOWN POLE. BORE PLACING NEW COMCAST (1)-2" CONDUIT AND CATV CABLE. CONTINUE BORE IN PRIVATE PROPERTY. ALL CONSTRUCTION AND RESTORATION TO MEET OR EXCEED CITY OF EDMONDS STANDARDS. New Vault V❑ Jan 08 2024 Existing U/G CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Existing Aerial a , sw LLLLLLLLLLLLJJJLLLII![[[��I � h al sv. U/G NewC1 ----- New Aerial '. I I j� ------------------- :.�• �•�,�---z __ - } ,,�r� \, � �2 9W I� I 208th St SW L11J_L l L L1 tsw tsw L nnwood - _ ; Y r I m - - i-r� �^-- .-.� �S I r _ �t Interior Path S,v �' ,da -g, sw noJ !� _ 99. 4 Lf ® / ®®� sa FL9� Exterior Building Path � 1 - 21I:ri S! S.V T Footage Break � _ _ In tru r ban Splice Point hoi - Trail ParkFiber Storage Loop Riser O Q9E ;t SW � o I� ti PoleIn a Lock Box Footage j T 2t g,g 1 1 .rytn 5t rr 'In!" PI. 5Y, Text i I i Ii -� .----- - _ - _.220th St SW_ _ � r1 (_i. "�"" .- _ _ _,�.-__�_-,I © Text Box Callout Arrow.31 r �� e MountiakesW Ll IAM 1�t �K t7-,, New Tap 11 _I - I It, te. 222rtt1;I us Phase Identifier ■ Epp-rancrPark 3u.a:ArRw - �9J I _ it a .. -,... s•.v .iry Park: 3,: at•.. .'•v, - ;• t- I .h}ti%,M., sv, �fp, --. '4ri l� . Power SuppY • = _ _ - - -I -- a ! ssw Hard Surface Cut :,,,� :5, i,v , _a �'��� . r LL�I TRAFFIC CONTROL Completed By: LEN ENRIQUEZ Address: 21701 76TH AVE W EDMONDS WA98026 Completion Date: 1/8/2024 Private Exterior Footages: Job Type: Select New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 0 New Aerial Fiber: 0 Overlash Fiber: 0 Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: No Job Subtype: Select Survey Scope: Post -Sale Project Manager: Select Source System: JB0001335034 1 Legend Provide Clear Private Exterior Construction Details TIE IN AT OVER LASH 3 POLES 2 SPANS 260'. PLACE NEW COMCAST (1)-2" RISER AND CATV CABLE DOWN POLE. BORE PLACING NEW COMCAST (1)-2" CONDUIT AND CAN CABLE. CONTINUE BORE IIN PRIVATE PROPERTY. ALL CONSTRUCTION AND RESTORATION TO MEET OR EXCEED CITY OF EDMONDS STANDARDS. New Ped ❑ New Vault ❑V Existing U/G Existing Aerial New U/G ——' New Aerial Interior Path Exterior Building Path Footage Break Fiber Splice Point Storage Loop CD rD Riser Pole Lock Box 150' Footage Text Text Box Callout Arrow New Tap ❑i Phase Identifier PS' Power Suppy Hard Surface Cut SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM SIGN SPACING = X (1) RURAL ROADS 45-55 MPH 500' -/- RURAL ROADS 8 URBAN ARTERIALS 35-40 MPH 350' +/- RURAL ROADS 6 URBAN ARTERIALS 25-30 MPH 200' +F (2) RESIDENTAL 6 BUSINESS DISTRICTS URBAN STREETS 25 MPH OR LESS 100' ♦/- (2) (1)ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS. (2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. ALL SIGNS ARE 48' X 48' BLACK ON ORANGE _NI.rSS OTHERWISE DESIGNATED MINIMUM LANE SHIFT TAPER LENGTH = L/2 �r F .•4r.-+ SPEED (MPH; 1 20 1 25 1 30 1 35 1 40 1 45 1 50 1 55 121 L/2 (feet) 1 40 1 80 110011501180127013201360 TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP VLi 1:Ia\T/ WIT1 MAXIMUM CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 50-65 40 80 35-45 30 60 20-30 20 40 R4-7B KEEP 24' 30' B/vV RIGHT RECEIVED Jan 08 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 20 25 30 35 40 45 50N4995 LENGTH (feet) 115 155 200 250 305 360 475 PROTECTIVE VEHICLE ROLL AHEAD DISTANCE = R NO SPFCIFIFD DISTANCE RFQUIRFD. STRATEGICALLY POSITION WORK VEHICLE TO PROTECT WORK CREW. STATIONARY TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R HOST VFHICI F WFIGHT 9,900 TO 22,000 lbs. HOST VEHICLF WEIGHT 22,001. IDS. UP TO 40 MPH 45-55 MPH UP TO 40 MPH 45-55 MPH 100, 12 3' 74' 1 100, W1-41_ VV20-1 ROAD < > < WORK AHEAD R , B L/2 x x VVORK AREAJ ® ® q q ® ®® tr Be ® so 2e rnln. reoorntnended - 1 L I _ ®� _ ereZSr rm ® IiSLP9 ®ea enrm m1 va In1 Jr—li ra F7_r9 Je7• 18 Ii9.J� Je ® �61 81 l01_ - - - - - - - - - - - - - - - - - r I - - - - - - - - 14 x I x r f ROAD CENTER LANE WORK CLOSED AHEAD AHEAD rrra• VV20s LEGEND N SIGN LOCATION ® SIGN LOCATION - 5' MOUNTING HEIGHT - RECOMMENDED ES © 12 CHANNELIZING DEVICES �+ PROTECTIVE VEHICLE REQUIRED L.''2 I L'2 I- DEVICE SPACING 1f2 DISTANCE FOR T I- OPPOSING TRAFFIC DEVICES IW� NOTES 1 . For long term projects, conflicting pavement markings no longer applicable must be removed or obliterated as soon as practicable. H z z Temporary markings shall be used as necessary and signs shall be post mounted. `m 3� 2. For speed limits of 30 mph or less, use sign W1-3 In lieu of sign W1-4. 3. Extend device taper across shoulder If applicable. ENGINEERING DIVISION 4. Protective vehicle with TMA required for roadways 45 mph or higher. For roads 40 mph or less - shall be a work vehicle placed strategically APPROVED AS NOTED to shield worts area. 5. Address pedestrian control through or around the work area. VV 1�/ o2iosi2o24 TYPICAL LANE SHIFT WITH TWO WAY LEFT TURN LANE TCP 21 1 RECEIVED Jan 08 2024 CITY OF EDMONDS CITY OF EDMONDS MyBuildingPermit.com DEVELOPMENT SERVICES DEPARTMENT Right -of -Way Application #1425274 - COMCAST- JB0001335034 Applicant First Name Last Name Company Name JESSAMIN SANTOS COMCAST Number Street Apartment or Suite Number E-mail Address 1701 JOHN F KENNEDY BLVD WACONSTRUCTI0N JOINTUSE@COMC City State Zip Phone Number Extension PHILADELPHIA PA 19108 (206) 401-2188 Contractor Company Name Cablecom LLC Number Street Apartment or Suite Number 1429 AVENUE D 339 City State Zip Phone Number Extension SNOHOMISH WA 98291 (360) 670-4291 (360) 454-3163 State License Number License Expiration Date UBI # E-mail Address CABLEL*971 DP 8/21/2025 FD99RSS79 SNOHOMISH.PERM ITTING@CABLECO Project Location Number Street Floor Number Suite or Room Number 21701 76TH AVE W City Zip Code County Parcel Number EDMONDS 98026 00580700002702 Associated Building Permit Number Tenant Name Additional Information (i.e. equipment location or special instructions)_ Work Location Property Owner First Name Last Name or Company Name * HR ACQUISITION I CORPORATION Number Street Apartment or Suite Number PO BOX 92129 City State Zip SOUTHLAKE TX 76092 Certification Statement - The applicant states: I certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. I have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work requires a licensed contractor to perform the work, the information will be provided prior to permit issuance. Date Submitted: 1/8/2024 Submitted By: JESSAMIN SANTOS Page 1 of 2 i CITY OF EDMONDS MyBuildingPermit.com Right -of -Way Application #1425274 - COMCAST- JB0001335034 Project Contact Company CABLECOM LLC Name: Name: LEAH Email: SNOHOMISH.PERM ITTING@CABLECOMLLC.NET IHLENFELDT Address: 1429 AVENUE D Phone (360) 670-4291 339 #: SNOHOMISH WA 98291 Project Type Activity Type Scope of Work Utility Purveyor Utility Work Disturbance of Surface Project Name: COMCAST- JB0001335034 'TIE IN AT OVER LASH 3 POLES 2 SPANS 260'. PLACE NEW COMCAST (1)-2" RISER AND Description of CATV CABLE DOWN POLE. BORE PLACING NEW COMCAST (1)-2" CONDUIT AND CATV Work: CABLE. CONTINUE BORE IN PRIVATE PROPERTY. ALL CONSTRUCTION AND RESTORATION TO MEET OR EXCEED CITY OF EDMONDS STANDARDS. Project Details Project Information Job Number JB0001335034 Page 2 of 2