Loading...
BLD2024-0192_Manufacturer_Specifications_and_Installation_Instructions_2.13.2024_11.33.24_AM_4056776ELECTRICAL DATA Power Output - PMAx (W P) Watt Class Sorting-(W) Nominal Power Voltage -VMPP (V) u Nominal Power Current-IMpp(A) to Open Circuit Voltage-Voc(V) Short Circuit Current- Isc (A) Power Density (W/mz) Panel Efficiency (%) Product Code': RECxxxAA Pure 390 395 400 405 0/+5 0/+5 0/+5 0/+5 41.5 41.8 42.1 42.4 9.40 9.45 48.6 48.7 10.22 10.25 211 214 21.1 21.4 9.51 9.56 48.8 48.9 10.28 10.30 216 219 21.6 21.9 410 0/.5 42.7 9.61 49.0 10.35 222 22.2 Power Output - PMAx(WP) 297 301 305 309 312 Nominal Power Voltage-VMPP(V) 39.1 39.4 39.7 40.0 40.2 O No minaIPowerCurrent- IMpp(A) 7.59 7.63 7.68 7- 7.72 7.76 Z Open Circuit Voltage - Voc(V) 45.8 45.9 46.0 46.1 46.2 Short Circuit Current - Isc(A) 8.20 8.24 8.28 8.32 8.36 Values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m2, temperature 25°C), based on a production spread with a tolerance of PMAx, Voc& I5c 13 %within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m2, temperature 20°C, windspeed 1 m/s).* Where xxx indicates the nominal power class (PMAx) at STC above. MAXIMUM RATINGS WARRANTY Operational temperature: -40...+85°C Standard REC ProTrust Maximum system voltage: 1000V Installed by an REC No Yes Yes Certified Solar Professional Maximum test load (front): +7000 Pa (713 kg/m2)' System Size All ,25 kW 25-500 kW Maximum test load (rear): -4000Pa(407kg/m2)* Product Warranty (yrs) 20 25 25 Max series fuse rating: 25A Power Warranty (yrs) 25 25 25 Max reverse current: 25 A Labor Warranty (yrs) 0 25 10 See installation manual for mounting instructions. Power inYear 1 98% 98% 98% Design load =Test load/1.5(safetyfactor) Annual Degradation 0.25% 0.25% 0.25% Power in Year 25 92% 92% 92% See warranty documents fordetails. Conditions apply Available from: CERTIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 IEC62804 PID IEC61701 Salt Mist IEC 62716 Ammonia Resistance IS011925-2 Ignitability (Class E) IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC 62321 Lead-freeacc. to ROHS EU 863/2015 ISO 14001, ISO 9001, IEC 45001, IEC 62941 CIUS C E [Ed�%J take ke wnnrey , 1take-e-way WEEE-compliant I-, tek Lead -Free recydmg"heme TEMPERATURE RATINGS* Nominal Module Operating Temperature: 44°C (±2°C) Temperature coefficient of PMAx: -0.26 %/°C Temperature coefficient of Voc: -0.24 %/°C Temperature coefficient of Isc: 0.04 %/°C *The temperature coefficients stated are linearvalues DELIVERY INFORMATION Panels perpallet: 33 Panels per 40ftGP/high cube container: 792 (24 pallets) Panels per13.6 m truck: 924 (28 pallets) Panels per 53fttruck: 891 (27 pallets) LOW LIGHT BEHAVIOUR Typical low irradiance performance of module at STC: 0 T w Irradiance (W/m2) Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar's Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia -Pacific. ENPHASE DATA SHEET IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. Connect PV modules quickly and easily to I08 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer's instructions. © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. I08 MA-DS-0003-01-E N-US-2022-03-17 Easy to install Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two -wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing Class II double -insulated enclosure Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21(UL 1741-SA) requirements * Only when installed with IQ System Controller 2, meets UL 1741. ** IQ8M and IQ8A supports split phase, 240V installations only. IQBM and IQBA Microinverters Commonly used module pairings' W 260 - 460 295 - 500 Module compatibility 60-cell/120 half -cell, 66-cell/132 half -cell and 72-cell/144 half -cell MPPT voltage range V 33 - 45 36 - 45 Operating range V 25 - 58 Min/max start voltage V 30 / 58 Max input DC voltage V 60 Max DC currentz [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration OUTPUT 1' 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit A: A: Peak output power VA 330 366 Max continuous output power VA 325 349 Nominal (L-L) voltage/range3 V 240 / 211 - 264 Max continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 50 - 68 AC short circuit fault current over 2 3 cycles Arms Max units per 20 A (L-L) branch circuit4 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85 leading - 0.85 lagging Peak efficiency % 97.6 97.6 CEC weighted efficiency % 97 97.5 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -400C to +600C (-400F to +1400F) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD) 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") Weight 1.08 kg (2.38 Ibs) Cooling Natural convection - no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor CA Rule 21(UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer's instructions. (1) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8MA-DS-0003-01-EN-US-2022-03-17 I RON RI DGE Class A Fire Rating Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating —the highest possible rating —from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 & UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Flush hMMount LJ_J_J Tilt Mount Any Slope Test Setup ulaihiniType Mounting System Mounting is tested as part of a system that includes type -tested modules and fire -rated roof covering Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. Burnl A burni Flame Spread of Flame Test Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame cannot spread 6 feet or more in 10 minutes. Type 1, 2, & 3 <_ 6 Degrees I Type 1, 2, & 3 Class A Class A 'Class A rated PV systems can be installed on Class A, B, and C roofs. Frequently Asked Questions What is a "module type"? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs. What if I have a Class C roof, but the jurisdiction now requires Class A or B? Generally, older roofs will typically be "grandfathered in", and will not require re -roofing. However, if 50% or more of the roofing material is replaced for the solar installation the code requirement will be enforced. Where is the new fire rating requirement code listed? 2012 IBC: 1509.7.2 Fire classification. Rooftop mounted photovoltaic systems shall have the same fire classification as the roof assembly required by Section 1505. Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas (WUI) and for very high fire severity areas. Many of these areas are found throughout the western United States. California has the most Class A and B roof fire rating requirements, due to wild fire concerns. Are standard mid clamps covered? Mid clamps and end clamps are considered part of the PV "system", and are covered in the certification. More Resources 97 Installation Manuals Visit our website for manuals that include UL 2703 Listing and Fire Rating Classification. What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All code -compliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5", which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am I required to install skirting to meet the fire code? No, IronRidge achieved a Class Afire rating without any additional racking components. What determines Fire Classification? Fire Classification refers to a fire -resistance rating system for roof covering materials based on their ability to withstand fire exposure. Class A - effective against severe fire exposure Class B - effective against moderate fire exposure Class C - effective against light fire exposure What if the roof covering is not Class A rated? The IronRidge Class A rating will not diminish the fire rating of the roof, whether Class A, B, or C. What tilts is the tilt mount system fire rated for? The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height. Engineering Certification Letters We offer complete engineering resources and pre -stamped certification letters. - UU LV 11 U....1UYt:.UU1 I. V If V11r41UYt:..U_. // I RON RI DGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. K3 Compatible with Flat & Pitched Roofs Force -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Corrosion -Resistant Materials XR Rails are IronRidge offers All XR Rails are made of marine -grade Oncompatible with a range of tilt leg aluminum alloy, then protected with an FlashFoot and options for flat anodized finish. Anodizing prevents surface other pitched roof M roof mounting and structural corrosion, while also providing attachments. applications. a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. i XR10 XR10 is a sleek, low -profile mounting rail, perfectly matched to regions without snow. It achieves 6 foot spans, while also staying light and economical 6' spanning capability Moderate load capability Clear anodized finish Internal splices available Rail Selection ■ XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans. 8' spanning capability Heavy load capability Clear & black anodized finish Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. 12'spanning capability • Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Load Rail Sp;,!iiiri!l11 W 0 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 f&,� I RON RI DGE UFO Family of Components Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family —Flush Mount, Tilt Mount and Ground Mount —are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. Stopper Sleeve �ii�d�atee�st into Bonded Splice Grounding Lug f�wg amMEL Universal Fastening Object (UFO) The UFO securely bonds solar modules to XR Rails. It comes assembled and lubricated, and can fit a wide range of module heights. Bonded Attachments dffufi the __I& I RON RI DGE Flush Mount System Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre -stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty ® Entire system and components meet �� Twice the protection offered by newest effective UL 2703 standard. competitors. System Diagram s�----------------u��---------- --- -- ------------------m----- - - - - -- --- -- --------------- ---mow-- -------- --- -- O UFO C Stopper Sleeve • Grounding Lug m Bonded Splice --L Ground Wire Q 6VWe* Eyg3hasd krrnFhdgen3o6+aasrrdbrainat3rt@rltienow&blo the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. 0 Go to IronRidgexom/UFO XR Rails UFO/Stopper d d ' XR1000 Only I �/ d d d N/A Bonded Splice Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters Enphase - M250-72, M250-60, M215-60, C250-72 & Power Darfon - MIG240, MIG300, G320, G640 Optimizers I SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating =Class A Class A N/A Modules I Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. XR Rails O XR10 Rail i A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear & black anod. finish XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear & black anod. finish Clamps & Grounding O — UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear & black finish Attachments O FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill & black finish Resources Stopper Sleeves _L Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Slotted L-Feet XR1000 Rail Bonded Splices A heavyweight mounting All rails use internal splices rail for commercial projects. for seamless connections. • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Drop -in design for rapid rail Bond and attach XR Rails attachment. to certified attachments. Secure rail connections Slot for vertical adjusting Clear & black anod. finish esign Assistant o from rough layout to fully E:Jngineered system. For free. o to IronRidge.com/design • T & Square Bolt options • Nut uses 7/16" socket • Assembled & lubricated • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits Mount Mls or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled NABCEP Certified Training 0%w Earn free continuing education credits, POP while learning more about our systems. Go to IronRidge.com/training © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 U-ANCHORTm I U2400-PVC MECHANICALLY ATTACHED SOLUTION FOR SINGLE -PLY ROOFING SYSTEM Front Product Specs Back Bolt • 3/8"-16 x 1.5" Bolt* • Material Type: 304 Stainless Steel Plate • Outer Diameter: 5-1/2" • Fastener Hole Diameter: 17/64" (8 holes) • Fastener Hole Pattern: 4-1/8" Diameter • Material Thickness: 0.047" (1.194mm) • Material Type: Galvalume° AZ55 • Cover Membrane • Manufacturer: Brand Specific OR Generic • Color: Default White* • Length:11.75" • Width:11.75" • Thickness: Default 60 mil* Patents • Visit www.anchorp.com/patents Packaging Specs • Sold Individually OR Full Box Quantity • Individual Weight: 0.75 Ibs • Full Box Quantity: 10 units • Box Weight: Approx. 10 Ibs • Box Dimensions: 13" x 11" x 13" • Full Pallet Quantity: 50 boxes • Pallet Dimensions: 48" x 40" x 67" * Specified option is standard. Custom options may be available for additional charge. Lead times may apply depending on roofing manufacturer and product availability. ANCHOR PRODUCTS'" Description The U2400-PVC is a lightweight rooftop attachment system consisting of a U-Anchor 2000 Series plate and cover membrane. The cover membrane is factory sealed to the top of the plate. The U2400-PVC provides a positive, watertight, manufacturer accepted attachment for mechanically attached and fully adhered PVC single -ply membranes. Advantages • Extremely strong and lightweight • Fast installation, approximate rate of 12 per man hour • Installs on any surface from flat to vertical U-Anchor Attachment The U2400-PVC is attached by fastening through the roofing assembly into the structural decking with 2-8 approved fasteners. The membrane cover is then hot air welded around the perimeter to the roof membrane. Fastener selection is dictated by the system assembly, deck type, and the project engineer. Refer to installation instructions and the specified roofing material manufacturer requirements before installing. Equipment Attachment To securely mount your rooftop equipment to the U-Anchor, after its installed, the connection nut must be fastened to approximately 20-25 torque pounds. Use a calibrated torque wrench during install to ensure appropriate results are achieved. Testing / Approvals • Accepted - All Major Roofing Manufacturers • LARR Listed Individual deck assembly reports available upon request. Ratings Results are base on plate performance only. • Ultimate Load - Shear: 4000 Ibs • Ultimate Load - Tension: 3000 Ibs Test was performed in accordance with: ICC -ES AC467 Section 3.2 Warranty • Standard 20 Year Material Only Warranty MADE IN ROOFING MANUFACTURER U. S. A. Anchor Products LLC. 888-S7S-2131 PO Box 1SS1 Secured Mounting SolutionsTM www.anchorp.com Colleyville, TX 76034 info@anchorp.com POWERWALL Tesla Powerwall is a fully -integrated AC battery system for residential or light commercial use. Its rechargeable lithium -ion battery pack provides energy storage for solar self -consumption, time -based control, and backup. Powerwall's electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market -leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. a.770].7aI_\►[a]11111111.9>me] In141_11[932W AC Voltage (Nominal) 120/240 V Feed -In Type Split Phase Grid Frequency 60 Hz Total Energy 14 kWh Usable Energy 13.5 kWh Real Power, max continuous Real Power, peak (10s, off-grid/backup) 5 kW (charge and discharge) 7 kW (charge and discharge) Apparent Power, max continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10s, off-grid/backup) Maximum Supply Fault Current 7.2 kVA (charge and discharge) 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device Imbalance for Split -Phase Loads 30 A 100% Power Factor Output Range +/- 1.0 adjustable Power Factor Range (full -rated power) Internal Battery DC Voltage +/- 0.85 50 V Round Trip Efficiency',' 90% Warranty 10 years 'Values provided for 25°C (77F), 3.3 kW charge/discharge power 2In Backup mode, grid charge power is limited to 3.3 kW. 3AC to battery to AC, at beginning of life. MECHANICAL SPECIFICATIONS Dimensions' 1150 mm x 755 mm x 147 mm (45.3 in x 29.6 in x 5.75 in) Weight' 114 kg (251.3 Ibs) Mounting options Floor or wall mount 'Dimensions and weight differ slightly if manufactured before March 2019. Contact Tesla for additional information. 753 mm 147 mm (29.6 in) (5.75 in) IT�S�L�r.�1 1150 mm (45.3 in) ENVIRONMENTAL SPECIFICATIONS Operating Temperature -20oC to 50°C (-4°F to 122°F) Recommended Temperature 0°C to 30'C (32'F to 86'F) Operating Humidity (RH) Up to 100%, condensing COMPLIANCE INFORMATION Storage Conditions -20oC to 30oC (-4°F to 86°F) Certifications UL 1642, UL 1741, UL 1973, Up to 95% RH, non -condensing UL 9540, IEEE 1547, UN 38.3 State of Energy (SoE): 25% initial Grid Connection Worldwide Compatibility Maximum Elevation 3000 m (9843 ft) Emissions FCC Part 15 Class B, ICES 003 Environment Indoor and outdoor rated Environmental RoHS Directive 2011/65/EU Enclosure Type NEMA 3R Seismic AC156, IEEE 693-2005 (high) Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m < 40 dBA at 30'C (86°F) T = S L n TESLA.COM/ENERGY TYPICAL SYSTEM LAYOUTS WHOLE HOME BACKUP Optional i Solar Solar inverter Main panel Backup Gateway Utility meter Grid including service disconnect T = S L Powerwall Whole home backup PARTIAL HOME BACKUP Optional Solar o 0 o O Solar inverter -------------------- Sub panel Backup Gateway Main panel Utility meter Grid T - 5 L n n Powerwall Backup loads Home loads NA - BACKUP - 2019-06-11 TESLA.COM/ENERGY POWERWALL Backup Gateway 2 The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self -consumption, time -based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal) 120/240V Feed -In Type Split Phase Grid Frequency 60 Hz Current Rating 200 A Maximum Input Short Circuit Current 10 kA' Overcurrent Protection Device 100-200A; Service Entrance Rated' Overvoltage Category Category IV AC Meter Primary Connectivity Secondary Connectivity User Interface Operating Modes Backup Transition Modularity Optional Internal Panelboard Revenue accurate (+/- 0.2 %) Ethernet, Wi-Fi Cellular (3G, LTE/4G)2 Tesla App T MECHANICAL SPECIFICATIONS Dimensions vveiynL Mounting options Support for solar self -consumption, 660 time -based control, backup, and off -grid Automatic disconnect for seamless backup Supports up to 10 AC -coupled Powerwalls 200A 6-space / 12 circuit Eaton BR Circuit Breakers Warranty 10 years ' When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 2 The customer is expected to provide internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. COMPLIANCE INFORMATION Certifications Emissions UL 67, UL 869A, UL 916, UL 1741 PCS CSA 22.2 0.19, CSA 22.2 205 FCC Part 15, ICES 003 660mmx411 mmx149mm (26 in x 16 in x 6 in) 20.4 kg (45 lb) Wall mount, Semi -flush mount T 0 5 L 1% 411 ENVIRONMENTAL SPECIFICATIONS Operating Temperature Operating Humidity (RH) Maximum Elevation Environment Enclosure Type 149 -200C to 50°C (-4°F to 122°F) Up to 100%, condensing 3000 m (9843 ft) Indoor and outdoor rated NEMA 3R T = 5 L n NA 2020-05-23 TESLA.COM/ENERGY