BLD2024-0220_Energy_Calculations_2.16.2024_3.46.39_PM_4066071
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2024 NEEA, All rights reserved Project & Applicant Information Project Title Faith Community Church - 2018 WSEC For Building Department Use: I Date: Feb 16, 2024 Project Address 10220 238th St SW Edmonds, WA 98020 Applicant Name Braxten Tacbian Applicant Phone 206-643-1525 Applicant Email info@Istresponsehvac.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial neral Building Use Type Religious Worship Building Cond. Floor Area 4,050 New Building Project Cond. Floor Area 4,050 General Project Types Alteration or Addition T Alteration Mechanical Scope Single Zone Systems &Equipment Floors Above Grade 1 Compliance Method Compliance Method 1 - General Mechanical Scope Mechanical Project Description Like -for -Like furnace replacement Economizer DOAS Ventilation Higher Equipment Equipment Efficiency Mechanical Project Type Mechanical Scope Exception(s) Provided? Efficiency Option Applied? Compliance Compliance Applied? Verification Alteration Single Zone Systems & No No NA COMPLIES Scope and Method Equipment Additional Efficiency Credits Included (AEC) Does building include occupancy classifications Yes Does project include DOAS equipment? No requiring DOAS? Based on project scope do TSPR requirements No Do all systems comply with Appendix D standard reference design or qualify for an exception to TSPR? No apply? Scope & Space Conditioning ALTERATION - SINGLE ZONE SYSTEMS & EQUIPMENIJ Compliance Verification COMPLIES Single Zone Air Systems Category - Furnace, warm air Air Systems Summary Information System/Equip ID Quantity of Items Supply Airflow Control Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source Paired with DOAS Ventilation energy recovery Energy Recovery Efficiency (%) A80lX080BM4SCAJ I Constant volume Unoccupied, no ventilation requirement Air Systems & Equipment - Heating System /Equip ID Heating System/Equip e g Type S ecific a p Heating Capacity g p HC Units Proposed Heating Efficiency p g y HE Units Efficiency Compliance Verification A801X080BM4SCAJ Furnace I Warm air, gas fired (AFUE) 1 80,000 1 Btu/h 80.0 1 AFUE COMPLIES Air Systems & Equipment Details System/Equip ID Area(s) Served Location In Project Documents - Plan/Detail # AWIX080BWSCA{{detail-2289}} Main Floor{fdetail-2255}} ALL {{detail-2272}} WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(4) Warm Air Furnaces