REVIEWED BLD2024-0098 Crow Lighting Summary2/7/24, 10:33 AM waenergycodes.com/print_ project_summary_form.php?k=aWQ9MjM2MDQmZnZpPTE4JmN0aT0=&print=1
LIGHTING COMPLIANCE SUMMARY
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI C ^ C tid7eriby: C2024 NEEA, All rights reserved
Project & Applicant
Information
Project Title
Crow LTG - 2018 WSEC
For Building Department Use: I Date: Feb 07, 2024
Feb 07 2024
B L D 2023-0344
CITY OFEDMONDS REVIEWED
DEVELOPMENT SERVICES
DEPARTMENT BY
Project Address
105 5thAve S
Edmonds, WA 98020
Applicant Name
Kevin Storm
A
Applicant Phone
PP
206-276-1532
Applicant Email
kevins@mainstreet-electric.com
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
General Occupancy
All Commercial
General Building Use Type
Retail, General Sales
Building Cond. Floor Area
930
New Building or
Project Cond. Floor Area
930
Floors Above Grade
1
General Project Types
Alteration
Addition
Alteration
Lighting Scope
Interior Lighting
Compliance Method
Compliance Method 1 - General
LiLighting Scope
g g P
Lighting Project
Description
2 new tracks with 9 LED lamps each for a total of 18 at 9W each. 5 pendants with a total of 35W.
Lighting Compliance
Project Type
Interior /Exterior
(Interior includes both interior
Luminaire Replacement Scope
Compliance Method
LPA Calculation
Compliance
Scope
& parking)
Adjustment
Verification
and Method
Alteration
Interior Lighting
50% or more replaced
Space by space
No Calculation Adjustments allowed
COMPLIES
Crow LTG - 2018 WSEC IV Date Feb 07,:21!!!M
Lighting Power Calculatio ALTERATION - INTERIOR LIGHTING (50 /o or more replaced) Compliance Verification COMPLIES
Compliance Method Space by space LPA Calculation Adjustment non,
Interior Lighting Power Allowance - Space by Space
General Space Type
Specific Space Type
Gross Interior Area (SF)
LPA (Watts/SF)
Total Watts Allowed
(SF x LPA x 1)
Total Proposed Watts
(LPD + Display LPD)
Compliance Status
Retail
General sales
1 1 930
1 1.05
977
Proposed Total LPD
161
Totals
977
161
COMPLIES
Proposed Lighting Power Density
Fixture Type
Fixture ID
Quantity of
Fixtures (#F)
Watts or
Wattage Limit
per Fixture
(WpF)
Total Linear
Feet (LF)
Watts per Linear
Foot (WpLF)
Total Watts
Proposed
(#F x WpF) or
(LF x WpLF)
Individual Fixtures
Direct / indirect pendant
Pendant
1 5
7
35
Linear Fixtures
Line voltage track (120V)
Tracks 1 and 2
18
1 7
1
126
Proposed Total LPD
161
Project Title Crow LTG - 2018 WSEC
Date
Feb 07, 2024
Proposed Fixtures Details LTERATION - INTERIOR LIGHTING (50% or more replaced)
Fixture Type/Application
Fixture ID
Location in Documents
Lamp Type
New or Existing -to -Remain
Individual Fixtures
Direct / indirect pendant
Pendant
Rctail
LED
Ncw
https://www.waenergycodes.com/print_ project_summary_form.php?k=aWQ9MjM2MDQmZnZpPTE4JmN0aT0=&print=1 1 /2
2/7/24, 10:33 AM
waenergycodes.com/print_ project _summary_form. php?k=aWQ9Mj M2M DQmZnZpPTE4JmN0aT0=&print=1
Fixture Description: pendant
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: Display/accent lighting, occupancy controls
Linear Fixtures
Line voltage track (120V)
Tracks 1 and 2
1 Retail
LED
New
How is linear fixture quantity defined?: Quantity of fixtures with current limiting device
Length of track (LT):
Fixture Description: Track Light
Are these fixtures located within a daylight zone?: No
Do these fixtures require specific application lighting controls?: Lighting for sale/demo, occupancy controls
https://www.waenergycodes.com/print_ project_summary_form.php?k=aWQ9MjM2MDQmZnZpPTE4JmN0aT0=&print=1 2/2