Loading...
SEE REV1 APPROVED FIR BLD BLD2023-1238+Architectural_Plan+10.4.2023_11.28.51_AM+382062824X36 VICINITY MAP ,o . 4 SITE _ 111 SUNSET AVENUE NORTH, EDMONDS, WA 98020 M,g1111 �1 W E GENERAL NOTES PROJECT CONTACTS ARCHITECT LANGE MUELLER 4 A55OGIATE5 OWEN KEEPER 130 LAKESIDE, SUITE 250 SEATTLE, HA g8122 (206) 325-2553 FAX: (206) 328-0554 OFFICE BUILDING TI E: owen®Imueller.com OWNER Edmonds Sunset LLG BRAD DECKER (Manager) III Sunset Ave. North, Suite 200 Edmonds, HA c18020 (206) 545-4%4 SUITE #105 EMAIL: BRAD@5EATTLERETAIL.NET 111 SUNSET AVENUE NORTH, EDMONDS, WA 98020 1. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR. 2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. 3. DRAWINGS ARE NOT TO BE SCALED. CONTACT ARCHITECT FOR RESOLUTION OF ANY CONFLICTS OR DISCREPANCY. 4. REPETITIVE FEATURES MAY BE DRAWN ONLY ONCE, BUT SHALL BE PROVIDED AS IF DRAWN FULL. 5. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS. 6. ALL DIMENSION LINES ARE TO FACE OF CONC. AND METAL STUD WALLS AND CENTERLINE OF COLUMNS AND BEAMS, UNLESS OTHERWISE NOTED. 7. IN THE EVENT OF FIELD ERRORS OR OMISSIONS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND MAKE NO REPAIRS WITHOUT APPROVAL. 8. GENERAL CONTRACTOR RESPONSIBLE FOR ALL CUTTING AND PATCHING. 9. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES. 10. CONTRACTOR TO VERIFY ALL FIELD DIMENSIONS AND CONDITIONS - ANY DISCREPANCY BETWEEN PLAN AND ACTUAL CONDITION IS TO BE BROUGHT TO THE ATTENTION OF ARCHITECT FOR RESOLUTION. 11. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS. ANY CHANGE TO SAME SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR REVIEW AND APPROVAL. 12. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGE AND PATTERN PRIOR TO INSTALLATION FOR ARCHITECT'S APPROVAL. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND PRODUCT DATA FOR ARCHITECT'S APPROVAL ON ALL SPECIAL ITEMS REQUIRING CUSTOM FABRICATION. 13. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS. 14. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECT'S REVIEW SHOWING LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS, FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE CABINETS ETC. 15. THE CONTRACTOR SHALL APPLY AND SECURE ALL OCCUPANCY, SEWER, STORM, WATER, ELECTRICAL AND OTHER PERMITS EXCEPT BUILDING PERMITS. CONTRACTOR SHALL PAY ALL NECESSARY FEES AND POST BONDS REQUIRED. 16. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS THAT THROUGH EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. 17. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECT'S APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION. 18. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLE AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. 19. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS SELECT ANY PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT FOUR (4) COPIES OF COMPLETE BACK-UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED. 20. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS MUST BE APPROVED BY ARCHITECT. 21. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 1 /4" IN 10"-0". THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. 22. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS, UNLESS SHOWN OR NOTED OTHERWISE. 23. GLAZING IDENTIFICATION LABELS ARE TO REMAIN ON ALL GLAZING UNTIL THE INSULATION INSPECTION IS COMPLETE. 24. PORTABLE FIRE EXTINGUISHERS PER NFPA 10 AND IN CONSTRUCTION SHACK. 25. PERMANENT FIRE EXTINGUISHERS BY OWNER. 26. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. 27. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. 28. INSPECTOR SHALL MAKE ANY FIELD MODIFICATIONS DEEMED NECESSARY IN ORDER TO MEET MINIMUM BUILDING CODE REQUIREMENTS. 29. ANY DEVIATION IN CONSTRUCTION FROM APPROVED PLANS REQUIRES PRIOR REVIEW AND APPROVAL FROM THE CITY. 30. REFER TO BASIC BUILDING SHELL SPECIFICATIONS AND STANDARDS FOR EXISTING SHELL CONSTRUCTION (IF APPLICABLE). ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. Approved DFM Ckrbs guvt South County Fire Date: 10/26/2023 10-26-2023 PLAN REVIEW NOTES: APPROVED WITH CONDITION: 1. A SEPARATE FIRE ALARM PERMIT IS REQUIRED IF A COMMERCIAL FIRE ALARM EXISTS. 2. SUITE NUMBER IS REQUIRED AT ENTRANCE TO SUITE 105. DFM BURT OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES DEFERRED SUBMITTALS � ABBREVIATIONS ADJ ADJUSTABLE / ADJACENT I. HVAG SYSTEM 15 DE516N/BUILD DEFERRED SUBMITTAL UNDER SEPARATE ALT ALTERNATE JAN JANITOR PERMIT. SYSTEM SHALL BE DE516NED BY A HASHINGTON STATE LICENSED AFF ABOVE FINISH FLOOR JB JUNCTION BOX ENGINEER. SYSTEM 15 TO CONFORM TO REQUIREMENTS OF HA5HINOTON ALUM ALUMINUM J5T JOIST STATE ENERGY CODE AND INTERNATIONAL ENERGY GON5ERVATION CODE. L AN6LE JT JOINT KIT KITCHEN MOUNTING HEIGHT OF CONTROLS SHALL COMPLY WITH ANSI 117.1-200q FOR ANOD. ANODIZED LF LINEAL FOOT ACCESSIBILITY, AND SHALL BE LOCATED BETWEEN 15" AND 44" FROM ACT ACOUSTICAL GEILIN6 TILE LT6 LIGHTING FINISH FLOOR. m AT MAT'L MATERIAL MAX MAXIMUM REFER TO ENVELOPE/ENEROY CALCULATIONS BY FRANKLIN ENGINEERING. BLD6. BUILDING MEGH MECHANICAL MED MEDIUM BLK'6. BLOGKIN6 MEZZ MEZZANINE MFR 2. ELECTRICAL SYSTEM 15 DE516N/BUILD DEFERRED SUBMITTAL UNDER BM BEAM MANUFACTURER SEPARATE PERMIT. SYSTEM 15 TO CONFORM TO REQUIREMENTS OF THE B/5 BUILDING STANDARD MI5G MI5GELLANEOU5 INTERNATIONAL ELECTRICAL CODE AND HA5HIN6TON STATE AMENDMENTS. MTD MOUNTED SYSTEM SHALL BE DE516NED BY A HASHIN6TON STATE LICENSED GAB CABINET MTL METAL ENGINEER. MOUNTING HE16HT OF CONTROLS AND RECEPTACLES SHALL GIRL CIRCULATION COMPLY WITH ANSI 117.1-200G FOR AGGE55IBILITY, AND SHALL BE GLR CLEAR OR CLEARANCE WA NOT APPLICABLE LOCATED BETWEEN 15" AND 44" FROM FINISH FLOOR. GL6 GEILIN6 NIG NOT IN CONTRACT GL GENTERLINE NO NUMBER 3. ALARM SYSTEM 15 DE516N/BUILD DEFERRED SUBMITTAL UNDER SEPARATE COL COLUMN NOM NOMINAL PERMIT. SYSTEM SHALL BE DE516NED BY A HA5HINOTON STATE LICENSED GONG CONCRETE NT5 NOT TO SCALE ENGINEER. SYSTEM 15 TO MEET REQUIREMENTS OF IBG, IFG, NFPAII3. GONST CONSTRUCTION COORDINATE IN5PEGTION5 AND FINAL IN5PEGTION WITH LOCAL GONT CONTINUOUS OG ON CENTER JUR15DIGTION FIRE DEPARTMENT. GOORD COORDINATE OPN'6 OPENING GPT CARPET OPP OPPOSITE 4. 516NAGE 15 A DEFERRED SUBMITTAL UNDER SEPARATE PERMIT. 516NA6E GT GERAMIG TILE SHALL CONFORM HITH LOCAL JURI5DIGTION ZONING CODE, LATEST PERP PERPENDICULAR ADOPTED EDITION. DET DETAIL PL PLATE OR PLA5TIG DIA DIAMETER LAMINATE 5. PLUMBING SYSTEM 15 DE516N/BUILD DEFERRED SUBMITTAL UNDER DIM DIMENSION PLYHD PLYHOOD SEPARATE PERMIT. SYSTEM SHALL BE DESIGNED BY A HA5HIN6TON DN DOHN PNL PANEL STATE LICENSED ENGINEER. SYSTEM 15 TO CONFORM TO REQUIREMENTS OF DR DOOR PR PAIR INTERNATIONAL PLUMBING CODE 4 HA5HIN6TON STATE AMENDMENTS. 0H6 DRAHIN6 PROP PROPERTY MOUNTING HE16HT OF CONTROLS SHALL COMPLY WITH AN51 117.1-200q FOR PT PAINT ACCESSIBILITY. EA EACH EL ELEVATION R. RADIUS 6. DOORS AND HARDWARE ARE BIDDER-DE516NED. HARDWARE 6ROUP5 AND ELEG ELEGTRIG RB RE51LIENT BASE DESCRIPTIONS ARE FOR GENERAL OPERATIONAL AND CODE COMPLIANCE ELEV ELEVATION OR ELEVATOR RF6R REFRIGERATOR INFORMATION. COORDINATE WITH OWNER FOR A 5PEGIAL 5EGURITY EN ENAMEL REINF REINFORCEMENT FUNGTION5. SUBMIT COMPLETE HARDWARE AND DOOR SCHEDULES WITH EQ EQUAL EXIST EXISTING REQ'D REQUIRED PRODUCT GUT SHEETS AND MATERIAL SAMPLES. DOORS AND HARDWARE FF FACTORY FINISH REV REVERSE OR REVISON SHALL COMPLY WITH IGG-ANI5117.1-200Q. FIN FIN15H RM ROOM FLR FLOOR RO ROUGH OPENING FLUOR FLUORE5GENT FOIG FURNISHED BY OWNER 5G 50LID GORE INSTALLED BY SECT SECTION CONTRACTOR SHT SHEET 51M 51MILAR FT FOOT / FEET 5M SHEET METAL FTIG FURNISHED BY TENANT SQ SQUARE INSTALLED BY 5TD STANDARD CONTRACTOR 5U5P SUSPENDED FURN FURNI5H / FURN15HINC75 6A 6AU6E TELE TELEPHONE 6ALV GALVANIZED TEMP TEMPERED 6L 6LA55 / 6LAZIN6 THERMO THERMOSTAT 6HB GYPSUM HALL BOARD TYP TYPICAL HDH HARDWARE VAR VARIES HM HOLLOW METAL VGT VINYL COMPOSITION TILE HGT HEIGHT VEN VENEER HVAG HEATING VENTILATING AIR VERT VERTICAL GONDITIONIN6 VHG VINYL HALL GOVERIN6 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE IN INCH H/ WITH INGAD INCANDESCENT H/O HITHOUT INGL INCLUDE HG HALL GOVERIN6 IN5UL INSULATION HD HOOD IN5TL INSTALLATION CODES 2018 I.B.G. WITH HASHINOTON STATE AMENDMENTS HAG 51-50 IGG/ANSI AII7.1-2017 AGGE551BILITY STANDARDS 2018 INTERNATIONAL MECHANICAL CODE $ HAG 51-52 2018 INTERNATIONAL FUEL GAS CODES (IMFOG) 8 HAG 51-52 2015 NATIONAL ELECTRICAL CODE (NEG) 2015 INTERNATIONAL FIRE CODE (IFG) i HAG 51-54A 2015 INTERNATIONAL PLUMBING CODE $ HAG 51-56 4 51-57 2015 UNIFORM PLUMBING CODE $ HAG 51-56 2015 ENERGY CONSERVATION CODE 2015 HASHIN6TON STATE ENERGY CODES, HAG 51-IIG AND 51-IIR 2015 INTERNATIONAL EXISTING BUILDING CODE, GH.S, CH. 8 LEVEL 2 ALTERATION CITY OF EDMONDS ZONING I CONSTRUCTION TYPE VB I OCCUPANCY GROUP B OCCUPANT LOAD 3 PROJECT DESCRIPTION TH15 PROJECT INVOLVES MINOR GHANOE5 TO THE INTERIOR OF THE EXISTING SUITE #105 OF THE BUILDING LOCATED AT III 5UN5ET AVENUE NORTH, EDMONDS, HA c18020 ALL THE WORK COVERED BY THI5 PERMIT 15 CONFINED TO THE INTERIOR OF THE BUILDING AND CONSISTS OF REMOVING TWO (2) INTERIOR SEPARATION HALLS AND BUILDING ONE SEPARATION HALL. IT'S IMPORTANT TO EMPHASIZE THAT THERE HILL BE NO 5TRUGTURAL MODIFICATION MADE, NO GHANGE OF USE, OCCUPANCY OR ANY GHANGE TO THE EXISTING BUILDING FLOOR AREA UNDER THI5 PERMIT. LEGAL DESCRIPTION EDMONDS PLAT OF ELK 013 0-00 - LOT 2 PROJECT STATISTICS ZONING B02-POHNTONN MIXED COMMERCIAL CONSTRUCTION TYPE GOMERGIAL OCCUPANCY GROUP B FIRE SPRINKLER YES EXISTING BUILDING FOOT PRINT 2,360 S.F. PARCEL NUMBER 00454401500200 LOT SIZE 0.16 ACRES DRAWING INDEX SHEET DESCRIPTION REV.NO ARCHITECTURAL AO.O COVER SHEET A2.0 EXISTING AND DEMO PLAN A2.1 NEW PLAN A4.0 5EGTION5 AND DETAILS Separate plumbing permit required. Please apply via MyBuildingPermit.com City Of Edmonds Building Department Work REMODEL Address 111 SUNSET AVE N 105 Owner SUNSET BLDG Approved Date 10/19/2023 Building Official------------------------------------------- Erlfi Permit Number BLD2023-1238 REVISIONS DATE - PAGES - CHANGES REV1 REV2 REV3 REV4 REV5 m N m O O W o z 0 Ln Q w Of m IZ I 0 z N o z 0< z o� �L z W w� m CV F m 0 0 0 c� U O � U Wo W � �Ijz V) CD 0 3 W Q w O (0 N O W Zw Q g' V C) qqr- O co U � OZ J J .. O H W 0 c/)W Z (D _ c/) c/) Z O 0 Z Z O � � J Z Q W Uj z U U LL Q EIV Oct 04 2023 CITY OF EDMONDS DEVELOPMENT SERVIC DEPARTMENT U Q Ln rn WI IN QN - Illl U Q � cq 0 N jj cn N Ul N �� w U J F- LL Q W Ld W cn J • J Ln Ln W N w cn I • W w U W� LU Z J w Q `r a J Q `� SHEET: 0� w > AO. 0 O U J 24X36 PLAN LEGEND / NOTES DEMO PLAN NOTES _'4 - REMOVE DASHED DOORS, WALL5, EXISTING WALL TO REMAIN _ CEILING TILE 4 GRID, FIXTURE5, TT-P. I. REFER TO ELEGTRIGAL AND MEGHANIGAL DRAWINGS FOR DEMOLITION EXISTING EXTERIOR WALL TO REMAIN REQUIREMENTS RELATED TO ELECT. AND MECH. 5GOPE OF WORK. 2. ALL EXISTING DOOR5, RELITE5, FRAME5, AND HARDWARE DE5I6NATED TO BE REMOVED, 5HALL BE SALVAGED FOR RE-U5E TO THE MAXIMUM EXTENT EXISTING DOOR TO REMAIN P0551BLE AND PRAGTIGAL. 3. 5ALVA6E AND REUSE, TO THE MAXIMUM EXTENT PRAGTIGAL, ELEGTRIGAL DEVIGE5 5UGH A5 OUTLET5, 5WITGHED, BOXES, A.V. GONTROL5, 5EN5OR5, THERM05TAT5, ETG. 4. EXISTING 5URFAGE5 AND FINI5HE5 5HALL BE PATCHED, REPAIRED, AND AREA OF WORK THI5 PERMIT FINI5HED TO MATCH EXISTING 5URROUNDING 5URFAGE5. REPLACEMENT AND REPAIR FINISH MATIERIAL5 5HALL MATCH EXISTING WHERE EVER PRATIGAL. AREA OF WORK FOR THIS PERMIT SUITE (E)105 r- -REMOVE EXISTING WALL- J SUITE E)104 LC I (E) ELECT PANELLEMOVE Alterations to the break room cabinetry x / _ /-r-R EXISTING -R DOOR will require the alterations will be required i `-REMOVE (E) BREAK ROOM to meet ADA standards. XIS II SHOWER AND L 5UROUNDING (pEMO; � � 0 EXIST _ - PARTITION WALL5 ° 0 A5 SHOWN ED I \� I �________� Z L.L SUITE (E)103 \ DECK EXIST xls xls SUITE - 0 D 0 (E)102 i XIS XIS cn \ X \ SUITE SUITE (E)101 (E)100 EXISTING AND DEMO PLAN o 2 4 8 12 A SCALE: 1 /4" = V-0" s m N m O O _ W o z 0 Ln Q w Of m w 0 z N o � z 0 z o� Z o LU m CV Ujm 00 0cr� c� U O U U Wo W � � jz N_ V) LLJ 3 W Q w (0 N O W Zw Q g' L0 C) IT- 0 co ::D c/i U C/) OZ J p H W 0 W � Z (DC/) _ C/) Z O 0 Z Z O LU ::D � J Z W W z U LL LL QCEIV Oct 04 2023 CITY OF EDMONDS DEVELOPMENT SERVIC DEPARTMENT rn U] L lfl W Ln N Q — l!1 N I'7 U Q tD N 0 N • jj Cn N N Ul3: QL � r W U J H LL Q W wLn zJ . QJ Ln Ln J W N W H O En Cf] I • LU 0W Ld M U Uo W z Q Q `r i O (D J Q `� SHEET: Z_ A2. 0 W C PERMIT 24X36 DAYLIGHT ZONE CONTROL CEILING PLAN NOTES FLOOR PLAN NOTES PLAN LEGEND / NOTES PROVIDE DAYLIGHT ZONE CONTROLS PER THE INTERNATIONAL ENERGY CONSERVATION I. PLANS AND FIXTURES ARE LISTED FOR DESIGN INTENT ONLY. FINAL FIXTURE I. PROVIDE 2A/IOBG FIRE EXTINGUISHERS 1/3000 S.F. MAX. WITH MAX. 75' TRAVEL EXISTING HALL TO REMAIN SECTION CODE G-405.2.2.3, AND PER HASHINGTON STATE NON-RESIDENTIAL ENERGY CODE SCHEDULE AND LAYOUT PER ELECTRICAL DESIGN BUILD DOCUMENTS. DISTANCE. GOORD. LOCATIONS w/ FIRE MARSHAL. BUILDING SECTIONS AMENDMENTS, HAG 51-IIG. X 2. PROVIDE EXIT 516NA6E PER IBG 1015. SIGNS SHALL BE ILLUMINATED AT ALL 2. PROVIDE EXIT 5162NA67E PER IBG 1015. SIGNS SHALL BE ILLUMINATED AT ALL A4. ALL DAYLIGHTED ZONES, AS DEFINED IN CHAPTER 2, BOTH UNDER OVERHEAD GLAZING TIMES. PROVIDE BATTERY BACKUP POWER FOR ILLUMINATION FOR MINIMUM OF CIO TIMES. PROVIDE BATTERY BACKUP POWER FOR ILLUMINATION FOR MINIMUM OF c10 EXISTING EXTERIOR HALL TO REMAIN AND ADJAGENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL MINUTES. PROVIDE TACTILE EXIT SIGNS GOMPLYING WITH IGG-AII7.1-2017 MINUTES. PROVIDE TACTILE EXIT SIGNS COMPLYING WITH IGG-Alll.l-201-7 SHEET CONTROLS, OR DAYLIGHT OR OGGUPANT-SENSING AUTOMATIC CONTROLS, HHIGH ADJACENT TO EACH STAIRWAY. ADJAGENT TO EACH STAIRWAY. NUMBER CONTROL THE LIGHTS INDEPENDENT OF GENERAL AREA LIGHTING. CONTIGUOUS DAYLIGHT ZONES ADJACENT OF VERTICAL GLAZING ARE ALLOHED TO BE 3. PROVIDE EXIT PATHWAY ILLUMINATION PER IBG SECTION 1008. THE POWER 3. PROVIDE EXIT PATHWAY ILLUMINATION PER IBG SECTION 1005. THE POWER NEW WALL PER HALL TYPE. DETAIL X DETAILS CONTROLLED BY A SINGLE CONTROLLING DEVICE PROVIDED THAT THEY DO NOT SUPPLY FOR THE MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED BY THE SUPPLY FOR THE MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED BY THE A1.2 INCLUDE ZONES FACING MORE THAN TWO ADJAGENT ZONES CARDINAL ORIENTATIONS (I.E. BUILDING POWER SUPPLY, AND WITH EMERGENCY POWER SUPPLY LASTING QO BUILDING POWER SUPPLY, AND WITH EMERGENCY POWER SUPPLY FOR MIN 90 NORTH, EAST, SOUTH, WEST). DAYLIGHT ZONES UNDER OVERHEAD GLAZING MORE THAN 15 MINUTES MINIMUM. MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED AT THE MINUTES. MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED AT THE RATE OF SHEET FEET FRO THE PERIMETER SHALL BE CONTROLLED SEPARATELY FROM DAYLIGHT ZONES RATE OF I FOOT CANDLE AT FLOOR LEVEL. I FOOT CANDLE AT FLOOR LEVEL. NUMBER ADJACENT TO VERTICAL GLAZING. EXISTING DOOR TO REMAIN 4. MECHANICAL � ELECTRICAL PENETRATIONS THROUGH RATED HALL OR FLOOR 4. PROVIDE EXTERIOR EGRESS ILLUMINATION WITH EMERGENCY POWER PER IBG _-- EXCEPTION: DAYLIGHT SPACES ENCLOSED BY HALLS OR CEILING HEIGHT PARTITIONS AND GONTAINING 2 OR FEWER LIGHT FIXTURES ARE NOT REQUIRED TO 5Y5TEM5 TO COMPLY w/ IBG SECTION 714. SECTION 100&. PROVIDE MIN. 90 MINUTES OF POWER, FOR ILLUMINATION PER 1005.3.5 X ENLARGED PLANS / DETAILS A1.2 HAVE A SEPARATE 5HITGH FOR GENERAL AREA LIGHTING. 5. PROVIDE EXTERIOR EGRESS ILLUMINATION WITH EMERGENCY POWER PER IBG DOOR NO. ----% SECTION 1005. PROVIDE MIN. cI0 MINUTES OF POWER, FOR ILLUMINATION PER 5. MECHANICAL CONTRACTOR TO PROVIDE BUILDING 8 TOILET VENTILATION PER 1005.3.5 THE IMG. 100 DOOR TAG REVISIONS 6. II ALL THRESHOLDS MAXIMUM 1/2 HIGH ABOVE FINISH FLOOR, EACH SIDE OF DOORS. OX --� HALL TYPE PRE DET.I/A2.1 7. MECHANICAL 8 ELECTRICAL PENETRATIONS THROUGH RATED HALL OR FLOOR SYSTEMS TO COMPLY w/ IBG SECTION 714. NAME W E NORTH DIRECTION 101 ROOM NAME 8 NUMBER S NOTE: HALL, FLOOR AND CEILING FINISHES TO LF BE COORDINATE WITH OWNER AND/OR TENANT PRIOR TO CONSTRUCTION. 24'-2" VERIFY IN PLACE < 0 SUITE ° z (E)105 y J = A v LU LU SUITE /(CE)104 w BREAK Alterations to the break room cabinetry \ FILL IN DOOR OPENING 0 < C2 ROOM EXIST will require the alterations will be required XIS to meet ADA standards. o LU I � / x1s l Z Q � SUITE (E)103 DECK EXIST x1s x1s SUITE (E)102 �® / I XIS XIS GWB X \ _ � 1I SUITE SUITE z (E)101 (E)100 = = O m z ih MTL 5TUD5 @ 24"O.G. GWB A BELOW CEILING LEVEL WALL TYPE NEW PLAN 0 2 4 8 12 A SCALE: 3" = 1'-0" SCALE: 1 /4" = 1'-0" s m N m O O W o z 0 Ln Q w Of m 0 z CV o� z 0 z 3: z Lu o w m CV � m 0 0 0 m c� o U O U W0 W � � jz N_ V) CDOf 3 W Q w � N O W w Z Q g' V , O O co U CO zz J p w 0 w � � _ `z^ v ) Cn z O 0 z Z O LU ::D � J Z Q W W z U LL LL QCEIV Oct 04 2023 CITY OF EDMONDS DEVELOPMENT SERVIC DEPARTMENT rn U] Ln lfl W Ln N Q — l!1 N I'7 U Q tD N 0 N • [n jj N rn N Q L � r 3: W U J H LL Q W wLn J • J o Ln W N W H Cf] I • W W U W� W z Q i J O SHEET: A2.1 W z C PERMIT 24X36 I. ATTACHMENT OPTIONS TO 5TRUGTURE (HOOD, GONGRETE OR STEEL) 2. ATTAGHMENT OPTIONS AT PARTITION a. ATTAGHMENT DEVIGES TO 5TRUGTURE y4 INGH ((bMM) DIAMETER X 3-INGH (75MM) LONG GL05ED-EYE HOOD 5GREH5; MINIMUM PENETRATION I a. ATTACH PARTITION TRACK TO 5U5PENDED GEILIN6 MAIN RUNNER WITH TWO INGH (25MM) INTO THE HOOD MEMBER. NO. 8 5-5GREH5. (DETAIL A ONLY.) b. NO. 12 6A. SPLAY HIRE LOOPED AROUND BOTTOM GHORD OF OPEN JOINT b. /4 INGH ((bMM) GL05ED-EYE BOLT THROU6H PARTITION TRACK. OR TRU55. c. 2-INGH X 2-INGH (50MM X 5OMM) METAL ANGLE WITH TWO NO. 8 5-5GREH5 c. METAL 2-INGH X 2-INGH (50MM X 50MM) ANGLE, ATTACHED TO GONGRETE IN PARTITION TRACK. OR STEEL WITH APPROVED FASTENERS. • SPLAY HIRE TO BE WRAPPED AROUND ITSELF THREE FULL TURNS; WITHIN d. TIE HIRE SPIKE MINIMUM 3/((,-INGH (5MM) DIAMETER X 2 INGHE5 (50 MM) A 3-INGH 05MM) LENGTH. LONG, DRILLED AND HAMMERED FOR GONGRETE. e. TIE HIRE HED6E ANGHOR/4 INGH X 1-3/4 INGHE5 ((bMM X 44MM), FOR GONGRETE. f. BEAM/FLAN6E GLAMPS FOR STEEL 5TRUGTURE MEMBERS. • SPLAY HIRE TO BE WRAPPED AROUND ITSELF THREE FULL TURNS; WITHIN A 3-INGH (75MM) LENGTH. 5TRUGTURE EX 15TI N6 INSULATION TWO 12 6A. SPLAY HIRES AT MAX. 8' O.G. 0 X Q 2 SUSPENDED GEILIN6 EXI5TIN6ROOF-J 5TRUGTURE PARTITION � I EXISTING GEILIN6 1 A4.0 EDGE TRACK SUSP. CEILING � SCALE. 3 - 1-0 0 PER PLAN �8 PER PLAN 5�8 z INTERIOR HALL PER HALL TYPE c w HALL GONSTRUGTION PER FLOOR PLAN 0 STUD HALL PER FLOOR PLAN MATCH NEW BASE w/ EXISTING BASE STEEL TRACK TO MATCH /� FIN15H FLOOR STUD DEPTH $ THIGKNE55 w/ %"(P EX I I BOLTS @ 36" O.G. \ (EMBED 3%") 2 A4.0 STEEL TRACK TO MATCH STUD DEPTH � THIGKNE55 w/ %" EXP. BOLTS @ 36" O.G. (EMBED 4") EXISTING CONCRETE SLAB WALL CONNECTION SLAB SECTION ° 2 4 8 12 2 A SCALE: 3" = 1'-0" SCALE: 1/2" = 1'-0" m N m O O w ¢ o z O Ln Q w Of m U..I i O z N o� z 0 z 3< of z Lu o w� m CV L m 00 �cr� c� U O u U Wo W � � jz N_ V) LLI 3 W ¢ � � N O W w Z Q g' V , C) qqr— O O Co c/ U co M J 0 W 0 W C/ Z (D _ Cn Cn Z O 0 Z Z O � � J Z 0 W � W Q Lu W z U L LL QCEIV Oct 04 2023 CITY OF EDMONDS DEVELOPMENT SERVIC DEPARTMENT rn ul < Ln lfl W Ln N QN — l!1 — U Q � Cq 0 N • jj Cn N ul N u, 00 Q(y) 3: U J F- a W wLo J • J o Ln �^ VJ W N Ld En I' w� 0 W 0 U ULu w QO J z SHEET: O ui A4.0 w C!) C PERMIT