APPROVED FIR RESUB 2 BLD2022-1484+Architectural_Plan+3.9.2023_3.18.35_PM+3412375ABBREVIATIONS:
ABBREVIATIONS:
ABBREVIATIONS:
GENERAL SYMBOLS LEGEND
PROJECT TEAM DIRECTORY
@
AT
0
DIAMETER
GA
#
POUND OR NUMBER
GALV
(E)
EXISTING
GC
(N)
NEW
GL
GLAM
AB
ANCHOR BOLT
GR
ABV
ABOVE
GWB
ACC
ACCESS
GYP
ACOUS
ACOUSTICAL
ACP
ASPHALT CONCRETE PAVING
HB
ACT
ACOUSTIAL CEILING TILE
HC
ACS PNL
ACCESS PANEL
HDO
AD
AREA DRAIN
HDR
ADA
AMERICANS WITH DISABILITIES
HDWD
ADJ
ADJUSTABLE
HDW
AFF
ABOVE FINISHED FLOOR
HM
AGGR
AGGREGATE
HORIZ
AIB
AIR INFILTRATION BARRIER
HP
ALT
ALTERNATE
HR
ALUM
ALUMINIUM
HR
APPROX
APPROXIMATE
HT
ARCH
ARCHITECTURAL
HVAC
APSH
ASPHALT
HW
AUTO
AUTOMATIC
HWT
BD
BOARD
ID
BITUM
BITUMINOUS
IN
BLDG
BUILDING
INCL
BLKG
BLOCKING
INSUL
BM
BEAM
INT
BO
BOTTOM OF
INV
BOT
BOTTOM
BRIG
BEARING
JB
BSMT
BASEMENT
JF
BUR
BUILT UP ROOFING
JT
CAB
CABINET
KIT
CB
CATCH BASIN
KO
CEM
CEMENT
CER
CERAMIC
LAM
CIP
CAST -IN -PLACE
LAV
CJ
CONTROL JOINT
LBS
CLG
CEILING
LF
CLK
CAULKING
LH
CLO
CLOSET
ILL
CLR
CLEAR
LOC
CMU
CONCRETE MASONRY UNIT
LP
CNTR
COUNTER
LT
COL
COLUMN
CONIC
CONCRETE
MAS
CONN
CONNECTION
MATL
CONSTR
CONSTRUCTION
MAX
CONT
CONTINUOUS
MB
CONTR
CONTRACTOR
MC
CORR
CORRIDOR
MDF
CPT
CARPET;CARPETED
MDO
CRS
COLD ROLLED STEEL
MECH
CSK
COUNTERSUNK
MEMB
CTR
CENTER
MEZZ
CU FT
CUBIC FEET
MFR
CT
CERAMIC TILE
MIN
MIR
DBL
DOUBLE
MISC
DEMO
DEMOLITION
MO
DET
DETAIL
MTD
DIA
DIAMETER
MTL
DIM
DIMENSION
MUL
DL
DEAD LOAD
DN
DOWN
N
DR
DOOR
N/A
DR OPNG
DOOR OPENING
NO
IDS
DOWNSPOUT
NOM
DSP
DRY STANDPIPE
NR
DT
DRAIN TILE
NTS
DW
DISHWASHER
NIC
DWG
DRAWING
CA
E
EAST
OC
EA
EACH
OD
EJ
EXPANSION JOINT
OFF
EL
ELEVATION
OH
ELEC
ELECTRICAL
OHWM
ELEV
ELEVATOR
OPNG
ENCL
ENCLOSURE
OPP
EQ
EQUAL
OSB
EQUIP
EQUIPMENT
EST
ESTIMATE
PBD
EF
EXHAUSTFAN
PCC
EXIST
EXISTING
PCF
EXP
EXPANDED; EXPANSION
PERF
EXP BT
EXPANSION BOLT
PERP
EXPO
EXPOSED
PL
EXT
EXTERIOR
PLAM
EW
EACH WAY
PLAS
PLWD
FA
FIRE ALARM
PNL
FB
FLAT BAR
PNT
FD
FLOOR DRAIN
PR
FE
FIRE EXTINGUISHER
PRCST
FEC
FIRE EXTINGUISHER CABINET
PSF
FF EL
FINISH FLOOR ELEVATION
PSI
FH
FIRE HYDRANT
PT
FHC
FIRE HOSE CABINET
PTN
FIN FLR
FINISH FLOOR
PVC
FF
FINISH TO FINISH
FIN
FINISH
R
FLASH
FLASHING
RA
FLR
FLOOR; FLOORING
RAID
FLUOR
FLUORESCENT
RD
FOC
FACE OF CONCRETE
REF
FOF
FACE OF FINISH
REFR
FOIC
FURNISHED BY OWNER -INSTALLED BY
REG
CONTRACTOR
REI NF
FOM
FACE OF MASONRY
REM
FOS
FACE OF STUDS
REQ
FP
FIREPROOF
RESIL
FPL
FIREPLACE
REV
FR
FRAME
RH
FT
FOOT OR FEET
RM
FTG
FOOTING
RO
FURR
FURRING
RWL
FUT
FUTURE
FW
FULL WIDTH
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GLASS
GLUE -LAMINATED
GRADE
GYPSUM WALL BOARD
GYPSUM
HOSE BIB
HOLLOW CORE
HIGH DENSITY OVERLAY
HEADER
HARDWOOD
HARDWARE
HOLLOW METAL
HORIZONTAL
HIGH POINT
HOUR
HOUR
HEIGHT
HEATINGNENTILATING/AIR CONDITIONING
HOT WATER
HOT WATER TANK
INSIDE DIAMETER
INCH
INCLUDED
INSULATION
INTERIOR
INVERT
JUNCTION BOX
JOINT FILLER
JOINT
KITCHEN
KNOCKOUT
LAMINATE; LAMINATED
LAVATORY
POUNDS
LINEAR FEET (FOOT)
LEFT HAND
LIVE LOAD
LOCATION
LOW POINT
LIGHT
MASONRY
MATERIAL
MAXIMUM
MACHINE BOLT
MEDICINE CABINET
MEDIUM DENSITY FIBERBOARD
MEDIUM DENSITY OVERLAY
MECHANICAL
MEMBRANE
MEZZANINE
MANUFACTURER
MINIMUM
MIRROR
MISCELLANEOUS
MASONRY OPENING
MOUNTED
METAL
MULLION
NORTH
NOT APPLICABLE
NUMBER
NOMINAL
NOISE REDUCTION
NOT TO SCALE
NOT IN CONTRACT
OVERALL
ON CENTER
OUTSIDE DIAMETER; OVERFLOW DRAIN
OFFICE
OVERHEAD
ORDINARY HIGH WATER MARK
OPENING
OPPOSITE
ORIENTED STRAND BOARD
PARTICLE BOARD
PRECAST CONCRETE
POUNDS PER CUBIC FOOT
PERFORATED
PERPENDICULAR
PLATE
PLASTIC LAMINATE
PLASTER
PLYWOOD
PANEL
POINT
PAIR
PRECAST
POUNDS PER CUBIC FOOT
POUNDS PER SQUARE INCH
PRESERVATIVE TREATED
PARTITION
POLYVINYL CHLORIDE
RISER
RETURN AIR
RADIUS
ROOF DRAIN
REFERENCE
S SOUTH OWNER TENANT
SAF SELF -ADHERED FLASHING 1. GRID LINE REFERENCE # SEATTLE-SNOHOMISH MILL COMPANY INC. VIRTUE CELLARS
533 5TH AVE S 2303 NW 193RD PL
SAM SELF -ADHERED MEMBRANE EDMONDS, WA 98020 SHORELINE, WASHINGTON 98177
SC SOLID CORE (425) 263-2474 (206) 930-8038
SCHED SCHEDULE � NAME
SD SMOKE DETECTOR 2. LEVEL / DATUM REFERENCE ELEVATION CONTACT: MIKE MCMURRAY CONTACT: JAKE EDENS
SECT SECTION EMAIL: GECK08080@GMAIL.COM EMAIL: JAKE@VIRTUECELLARS.COM
SG SAFETY GLAZING ARCHITECT CONTACT: KEVIN MUELLER
SHV SHELF; SHELVING EMAIL: KEVIN@VIRTUECELLARS.COM
SHR SHOWER X Drawing Number GRAHAM BABA ARCHITECTS
3. EXTERIOR ELEVATION REFERENCE 1507 BELMONT AVE #200
SHR SHEET
AXXX Sheet Number SEATTLE, WA 98112
SHT MTL SHEET METAL 206-323-9932
SHTG SHEATHING
SIM SIMILAR # CONTACT: LAUREN KEENE
SOG SLAB ON GRADE Drawing Number EMAIL: LAURENK@GRAHAMBABA.COM
�
SPEC SPECIFICATION
SQ FT SQUARE FOOT (FEET) 4. INTERIOR ELEVATION REFERENCE # AX.XX #
Sheet Number
SQ IN SQUARE INCH(ES)
SST STAINLESS STEEL #
STD STANDARD
STL STEEL
STOR STORAGE X Drawing Number
STRUCT STRUCTURAL 5. BUILDING SECTION REFERENCE AXXX Sheet Number GENERAL NOTES
SUSP SUSPENDED
SYM SYMETRICAL 1 CODES: ALL WORK SHALL CONFORM TO APPLICABLE LAND USE AND BUILDING
CODES AS AMENDED BY AUTHORITIES HAVING JURISDICTION.
T TREAD -"" Drawing Number
T&G TONGUE AND GROOVE X 2 DO NOT SCALE DIMENSIONS FROM DRAWINGS. USE CALCULATED DIMENSIONS
6. WALL SECTION REFERENCE AXXX Sheet Number ONLY. NOTIFY THE ARCHITECT IMMEDIATELY IFA NY CONFLICTS EXIST.
TEL TELEPHONE
TER TERRAllO 3 ALL DIMENSIONS ARE TO EXTERIOR FACE OF CONCRETE / WOOD FRAMING
TG TEMPERED GLASS UNLESS NOTED OTHERWISE.
THK THICK
TO TOP OF Drawing Number 4 CONTRACTOR SHALL VERIFY ALL CONDITIONS PRIOR TO INITIATING THE WORK.
TOB TO OF BEAM 7. DETAIL SECTION REFERENCE X Sheet Number NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
AXXX
TOC TOP OF CONCRETE; CURB 5 VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT. PROVIDE ALL BUCK -OUT
TOF TOP OF FLOOR; FOOTING; FRAME BLOCKING,BACKING AND JACK REQUIRED FOR INSTALLATIONS.
TOM TOP OF MASONRY
TOP TOP OF PARAPET; PAVEMENT 6 ALL WOOD IN CONTACT WITH CONCRETE IS PRESURE TREATED.
TOPO TOPOGRAPHY X Drawing Number 7 SERVICE WATER PIPES IN UNHEATED SPACES TO BE INSULATED.
TOS TOP OF SLAB; STEEL 8. CALLOUT/DETAIL REFERENCE AXXX Sheet Number
TOW TOP OF WALL 8 PROVIDE FIRE -STOPPING AT ALL INTERSECTIONS BETWEEN CONCEALED WALL
TS TUBE STEEL AND HORIZONTAL SPACES, SUCH AS SOFFIT OR CEILING.
TSTAT THERMOSTAT
TYP TYPICAL 9 PROVIDE DRAFT -STOPPING IN CONCEALED SOFFIT SPACES WHERE REQUIRED.
UNO UNLESS NOTED OTHERWISE 10 ALL INSULATION MATERIALS SHALL HAVE FLAMED -SPREAD RATINT NOT TO
EXCEED 25 AND ASMOKE-DEVELOPED RATING NOT TO EXCEED 450.
VB VINYL BASE 11 CLEAR DEBRIS FROM ALL VENTILATION DRILL HOLES AND NOTCHES
VEN VENEER
VERT VERTICAL 9. REVISION REFERENCE 12 REMOVE ALL UPC STICKERS AND LABELS FROM PIPING, HANGERS, ETC,
VEST VESTIBULE UNLESS REQUIRED BY CODE PRIOR TO INSTALLATION.
VG VERTICAL GRAIN CD
VIF VERIFY IN FIELD
VT VINYL TILE
W WEST 10. ROOM REFERENCE
W/ WITH BUILDING CODE INFORMATION
W/0 WITHOUT
WC WATER CLOSET
WD WOOD 11. ASSEMBLY REFERENCE UNDER SEPERATE PERMIT
WDW WINDOW BASE BUILDING ARCHITECTURE, MECHANICAL, PLUMBING, STRUCTURAL,
WF WIDE FLANGE ELECTRICAL, CIVIL, WATER, LANDSCAPE PERMITTED UNDER PERMIT BLD2019-0530
WF BM WIDE FLANGE BEAM
WG WIRED GLASS 12. WINDOW REFERENCE W# APPLICABLE CODES
WH WATER HEATER 2018 INTERNATIONAL BUILDING CODE - WASHINGTON STATE AMENDMENTS
WL WATER LINE ICC/ANSI 1171-2009 ACCESSIBILITY CODE - WASHINGTON STATE AMENDMENTS
WILD WELDED 2018 ENERGY CODE - WASHINGTON STATE AMENDMENTS
WP WATERPROOF 13. DOOR REFERENCE D001 2018 INTERNATIONAL MECHANICAL CODE
2018 UNIFORM PLUMBING CODE
WPM WATERPROOF MEMBRANE 2018 INTERNATIONAL FIRE CODE
WR WATER RESISTANT N NATIONAL ELECTRICAL CODE (NFPA 70)
WSCT WAINSCOT
CODE AUTHORITY
WSG WIRE SAFETY GLASS 14. NORTH ARROW
WTR WATER CITY OF EDMONDS MUNICIPAL CODE
WWF WELDED WIRE FABRIC EXISTING USE I OCCUPANCY
WWM WELDED WIRE MESH A-2 ASSEMBLY, RESTAURANT (SECTION 303)
WT WEIGHT B BUSINESS, BACK OF HOUSE AND SUPPORT SPACES (SECTION 304)
MATERIALS LEGEND B BU� SS,EATING AND DRINKING ESTABLISHMENT � LESS T�50 OCCUPANTS (IBC ION 303)
WOOD BLOCKING
(SHIM)
FINISHED WOOD
BATT INSULATION
GRAVEL
ALUMINUM
MASONRY (CMU)
APPROVED
REFRIGERATOR
REGISTER
REINFORCED LANS MUST
REMAINDER
REQUIRED
RESILIENT
REVISION(S); REVISED
RIGHT HAND ON JO SIT
ROOM
ROUGH OPENING
RAIN WATER LEADER
WOOD FRAMING
(CONTINUOUS)
PLYWOOD
LLFFL
RIGID INSULATION
EARTH
STEEL
BRICK
TENANT STORIES
ONE
CONSTRUCTION TYPE
TYPE V - CONSTRUCTION: VB
REF. SHEET A0.02 FOR ADDITIONAL CODE INFORMATION Approved
DFM Chris Burt
South County Fire
Date: 03/22/2023
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
•R3
03-22-2023
PLAN REVIEW
NOTES: RESUB APPROVED
DEFERRED SUBMITALLS
1. FIRE SPRINKLER
2. FIRE ALARM
DFM Burt
CONSTRUCTION TYPE VB
OCCUPANCY GROUP B
1 OCCUPANT LOAD 40
N
VICINITY MAP
NOT TO SCALE
PROJECT DESCRIPTION
PROJECT DESCRIPTION
TENANT TO OCCUPY TENANT SPACE #3 OF THE MAIN STREET COMMONS EAST
BUILDING.
THIS PROJECT WILL PROVIDE AN INTERIOR TENANT IMPROVEMENT TO 540 SF
WITHIN A NEW 5,922 SF COMMERCIAL BUILDING (UNDER SEPARATE PERMIT
BLD2019-0530)
TENANT SPACE TO FUNCTION AS A WINE TASTING ROOM. BUILDOUT TO INCLUDE
NEW: BACK OF HOUSE, SCULLERY (NO TYPE I OR TYPE II HOODS REQ'D), STORAGE,
FRONT OF HOUSE BAR AND INDOOR & OUTDOOR SEATING
NO EXTERIOR WORK PROPOSED.
NO PRODUCTION ON SITE.
ZONING INFORMATION
LEGAL DESCRIPTION
LOTS 15 AND 16, BLOCK 120, CITY OF EDMONDS ADDITION, ACCORDING
TO THE PLAT THEREOF, RECORDED IN VOLUME 2 OF PLATS, PAGE 39,
RECORDS OF SNOHOMISH COUNTY, WASHINGTON.
AND;
LOTS 17, 18, 19 AND 20, BLOCK 120, CITY OF EDMONDS ADDITION,
ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 2 OF PLATS,
PAGE 39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON.
PROJECT LOCATION PARCEL NO.
550 MAIN STREET 004342-120-015-00 AND 004342-120-017-00 (BEING COMBINED
EDMONDS, WASHINGTON 98020 UNDER SEPARATE APPLICATION)
ZONE
BD1
LOT AREA
19,791 SF SF (SNOHOMISH COUNTY)
DRAWING INDEX
G0.01
G0.02
A0.01
A1.01
A2.01
A6.01
GENERAL NOTES AND PROJECT INFORMATION
GENERAL ADA AND CLEARANCE REQUIREMENTS
EGRESS AND CODE INFORMATION
SITE PLAN
FLOOR PLAN
OVERALL RCP - LEVEL 01
City Of Edmonds
Building Department
Work TENANT IMPROVEMENT
Address 558 MAIN ST STE 104
Owner VIRTUE CELLARS
Approved Date 03/20/2023
Building Official Eriz- C4wfe�r
Permit Number BLD2022-1484
REV1
REV2
REV3
REV4
REV5
REVISIONS
?MOM
Ak
1507 Belmont Ave, Suite 200
Seattle, Washington 98122
206.323.9932
1 12/28/22 Rev 1 - Permit corrections
No.: Date: Description:
Revisions:
RESUB
Mar 10 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
V
PERMIT SET
10/18/2022
Virtue Cellars
Tasting Room
558 MAIN STREET #104
EDMONDS, WA 98020
Project No.: 2137
Scale: 12" = 1'-01,
Sheet contents:
GENERAL NOTES
AND PROJECT
INFORMATION
Sheet:
G0001
CODE DOOR HARDWARE NOTES:
1 HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON ACCESSIBLE
DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT
REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE.
2 OPERABLE PARTS OF ACCESSIBLE DOOR HARDWARE SHALL BE 34" MINIMUM AND 48"
MAXIMUM ABOVE THE FLOOR. WHERE SLIDING DOORS ARE IN THE FULLY OPEN
POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH
SIDES.
32" MIN
ml
32" MIN SLIDING DOOR
HINGE DOOR
32" CLR
36" MI
NA MIN
DOORWAYS W/O DOORS FOLDING DOOR
CODE DETAILS DOORWAYS
SCALE: 1/2" = V-0"
z
I I
I I
I I
I I
I I
I I
I I
I I
I I z
CID
I I d
30" MIN
FORWARD APPROACH
I I
I I
I I
I
z z
2
I
Cl)
I
I I
I I
I
L J
48" MIN 60" MIN
PARALLEL APPROACH MANUEVERING CLEARANCE IN AN ALCOVE
CODE DETAILS CLEAR FLOOR SPACE
0
eo
n
30" MIN
FORWARD APPROACH
SCALE: 1/2" = V-0"
MAX
X
Q
oc
OBJECTS WITH LEADING
EDGES MORE THAN 27" UP
TO 80" A.F.F. SHALL NOT
PROTRUDE MORE THAN 4"
"' HORIZONTALLY INTO THE
CIRCULATION PATH
I A,�
CODE DETAIL PROTRUDING OBJECT
�1 1/2" MAX
CURVED NOSING
Q 11" MIN
TY
z
VERTICAL RISER
�30 MAX
ANGLED RISER
1 1/2" MAX
BEVELED NOSING
CODE DETAILS STAIR
BOTTOM HANDRAIL TOP HANDRAIL
EXTENSION AT STAIR EXTENSION AT STAIR
TOP & BOTTOM OF HANDRAIL EXTENSIONS AT RAMPS
CODE HANDRAIL NOTES:
1 HANDRAILS SHALL EXTEND BEYOND & IN THE SAME DIRECTION OF STAIR FLIGHTS &
RAMP RUNS.
2 EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR
SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT OR RAMP
RUN.
CODE STAIR NOTES:
1 ALL STEPS ON A FLIGHT SHALL HAVE UNIFORM RISER HEIGHT & TREAD DEPTH, TYP.
2 OPEN RISERS SHALL NOT BE PERMITTED.
3 PROVIDE HANDRAILS BOTH SIDES.
4 THE LEADING 2" OF EACH TREAD SHALL HAVE VISUAL CONTRAST FROM THE
REMAINDER OF THE TREAD.
5 STAIR TREADS SHALL COMPLY WITH ALL FLOOR SURFACE REQUIREMENTS.
6 STAIR TREADS & LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO
PREVENT THE ACCUMULATION OF WATER.
CODE TURNING SPACE NOTES:
CODE ACCESSIBILITY NOTES:
1 FLOOR SURFACES OF A TURNING SPACE SHALL HAVE A SLOPE NOT STEEPER THAN 1:48.
1 ACCESSIBLE ROUTES SHALL BE A MINIMUM OF 36" ON INTERIOR ROUTES AND 44" ON
2 TURNING SPACES SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCES.
EXTERIOR ROUTES AND BE FREE OF ALL OBJECTS THAT PROTRUDE MORE THAN 4"
3 UNLESS OTHERWISE SPECIFIED, DOORS SHALL BE PERMITED TO SWING INTO THE TURNING SPACES.
INTO THE ROUTE BETWEEN 27" AFF AND 80" AFF, INCLUDING FIRE EXTINGUISHER
CABINETS, MAILBOXES, WALL -MOUNTED TELEVISIONS, DRINKING FOUNTAINS, ETC.
60"
2 ALL PUBLIC EXTERIOR DOOR FORCES SHALL MEET 10 POUNDS OF FORCE OR LESS,
12" 36" 12"
INTERIOR DOORS MUST HAVE A 32" CLEAR OPENING WHEN OPEN AT 90 DEGREES.
3 SIGNS THAT IDENTIFY PERMANENT ROOMS AND SPACES SHALL HAVE TACTILE, RAISED,
AND BRAILLE CHARACTERS AND PICTOGRAMS. THESE SIGNS SHALL BE MOUNTED 60"
AFF TO THE BOTTOM OF THE TOP MOST LETTERS AND NOT LESS THAN 48" AFF TO THE
r-------------------------� \
BOTTOM OF THE LOWEST LETTERS OR CHARACTERS. SIGN SHALL BE LOCATED ON THE
LATCH SIDE OF THE DOOR, APPROXIMATELY 9" FROM THE JAMB ON CENTER.
4 TRANSITIONS BETWEEN FLOOR MATERIALS SHALL BE LEVEL VERTICAL UP TO 1/4" OR
BEVELED 1:2 UP TO 1/2".
5 TRASH DISPOSAL UNITS MUST BE ON AN ACCESSIBLE ROUTE, HAVE CONTROLS WITHIN
THE REACH RANGE, HAVE A CLEAR FLOOR SPACE OF 30" X 48" FOR EITHER A
FORWARD OR SIDE APPROACH TO ALLOW USE OF THE DISPOSAL UNIT, CENTERED ON
060" Ml
THE CONROLS AND BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
PINCHING, GRASPING OR TWISTING. THE FORCE TO OPERATE CONTROLS SHALL BE 5
r r
POUNDS MINIMUM.
6 OPERABLE PARTS ON TOWEL DISPENSERS AND HAND DRYERS SHALL COMPLY WITH
THE FOLLOWING: AT MAXIMUM REACH DEPTH 0.5": 48" MAX REACH HEGHT REQUIRED,
N
AT MAXIMUM REACH DEPTH 2": 46" MAX REACH HEIGHT REQUIRED, AT MAXIMUM
REACH DEPTH 5": 42" MAX REACH HEIGHT REQUIRED, AT MAXIMUM REACH DEPTH 6":
`
40" MAX REACH HEIGHT REQUIRED, AT MAXIMUM REACH DEPTH 9": 36" MAX REACH
I �� ,-'�
HEIGHT REQUIRED, AT MAXIMUM REACH DEPTH 11": 34" MAX REACH HEIGHT
REQUIRED.
T-SHAPED TURNING SPACE CIRCULAR TURNING SPACE
CODE DETAILS TURNING RADIUS
SCALE: 1/2" = V-0" SCALE: 1/2" = V-0"
EXTENSION BEYOND HINGE
REQUIRED IF BOTH CLOSER r , w o
AND LATCH ARE PROVIDED 77> 10 o
r
0 00
U r-------------- j� r
= H LU Z_ D O_
0 � LU
0 > Z I U z ///
m z o Imo// 42" MIN co 36" MIN w w
Z a 1 22" 12" 1 "' No � 24" o 04 1 24"
�ro cwn � MIN MINI MIN MIN
Q------- z------- z-------
CID
30" MIN L. 30" MIN
HINGE APPROACH: HINGE APPROACH: HINGE APPROACH: LATERAL APPROACH: LATERAL APPROACH:
r - r r PUSH SIDE PULL SIDE PULL SIDE PULL SIDE PUSH SIDE
I I I
I I I I
I I I I
I I I I
7
I I I I I I
I I I I I I
r r
I I I I I I I I I I
Z I
I II I z I I z I I g I z_
12" C=) 18"
ib ib a° _ = 00
--- ------ X MIN X x MIN
z 12" EXTENSION BEYOND
N LATCH REQUIRED IF EXTENSION BEYOND
N CLOSER AND LATCH LATCH = 0" IF NO
I I I I
r --- --- -- J L ------ -- -1 ARE PROVIDED CLOSER AND LATCH
FRONT APPROACH: FRONT APPROACH: FRONT APPROACH:
TOE CLEARANCE: KNEE CLEARANCE: PUSH SIDE W/ BOTH PUSH SIDE PULL SIDE
PLAN PLAN CLOSER & LATCH
CODE DETAILS DOOR AND DOORWAY APPROACH
UNOBSTRUCTED SIDE REACH
CODE DETAILS REACH RANGES
SCALE: 1/2" = V-0" SCALE: 1/2" = V-0"
Q
00
SCALE: 1/4" = V-0"
UNOBSTRUCTED FORWARD REACH
NOTE: THE REQUIREMENT FOR
KNEE AND TOE CLEARANCES
54" MIN FORWARD OF REAR WALL SHALL NOT APPLY TO MORE
THAN ONE BOWL OF A
MULTIBOWL SINK (UNLESS
- 12" 0 39" 41" PROVIDE 48"X30" CLEAR RESIDENTIAL USE)
1AX MIN 1 36" MIN o CO FLOOR SPACE AT
~ o URINAL PER SECTION
0 z 305 ICC/ANSI Al17.1
N ? 12" 42"MIN z PROVIDE ACCESSIBLE
- o MAX CONTROLS
Of q
AND 48"X30" CLEAR FLOOR
7„ 9„ SPACE AT SINK PER SECTION
305 ICC/ANSI Al17.1
-- ---- J w
U
v U O �
o w INSULATE EXPOSED
MTP OLL w M v z m> HOT WATER AND DRAIN
v 0 PIPES, TYP
M V H M Q
v =o 18" N
Of
It It
ACCESSIBLE URINAL MIRROR OVER
7TP DISPENSER ONE MIN WHERE SINK
LOCATED
CODE DETAILS MOUNTING HEIGHTS
Q
0C
OBSTRUCTED SIDE REACH
r 1
I I I
I
1
I I
I I
I I
I I
I I
32"
CLR MIN
FRONT APPROACH:
SLIDING (S) & FOLDING (F)
11" MAX
0 WATER
e
z � e
a °
H
r-- Z 0- W z
~
UJ
,
� U aO z 0
w 0 O
o z O 00 H JJ
° ~ J w w Of Z ,I O O c� m0 w 3:U =
1- ~ Z 0 U Z
o N Q O Li- i� 0 2
of Q O N LLIQ v
O_ co 2
6" 11" MIN SOAP NAPKIN SEAT COVER SEAT COVER BABY CHANGING
�� DISPENSER DISPOSAL DISPENSER AT DISPENSER AT STATION
TOE KNEE BACK WALL SIDE WALL
KICK CLEARANCE
I I
I I
z
� I I
iv 24"
v
MIN 1
- -- 32 �
CLR MIN
STOP OR LATCH APPROACH S&F
Q
00
(A
OBSTRUCTED FORWARD REACH
r
1 I I 1
I
I I I
I I I
U U
I _ I
V v
N z% � z
0 0
FRONT APPROACH SIDE APPROACH
O
O
0
r ,
E::::>
04
I
Z
� I I
22"MIN
MIN CO
32"
CLR MIN
o F-
O
o �
POCKET OR HINGE APPROACH S&F
Al-
-1- C
w w
z 0
X: Z J
J m
Q m U
v w � w
U
O U U
Q Q
W w
w w
U
TOWEL HAND DRYER
DISPENSER
60" MIN
w
�
J
2
w
�
O
o
=
D_
w
w
=
J
0o
Q
Z
w
U
_
U
-
M nl
z
00
CD
Z
V
0
00
W
2
Z
N
F.-
cV
z
w
IL
O
11
It
It
LIGHTING,
FIRE
FIRE GARBAGE
ENVIRONMENTAL
EXTINGUISHER
EXTINGUISHER SLOT
& APPLIANCE CONTROLS,
CABINET
AND FIRE ALARM PULL
STATIONS
nnnR 49"
8"
MIN
TOE / KNEE CLEARANCE ELEVATION
0
o DIMENSIONS
TO J-BOX
0
O
°
°
❑
O
2
U
JJ
OJJ
(V
C
_ z
o
U �
"r Q
V
V
HOOK
SHELF ELECTRICAL OUTLET
AND COMMUNICATION
SYSTEM RECEPTACLES
1507 Belmont Ave, Suite 200
Seattle, Washington 98122
206.323.9932
No.: Date: Description:
Revisions:
RESUB
Mar 10 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
PERMIT SET
10/18/2022
Virtue Cellars
Tasting Room
558 MAIN STREET #104
EDMONDS, WA 98020
Project No.: 2137
I Scale: As indicated
Sheet contents:
GENERAL ADA AND
CLEARANCE
REQUIREMENTS
Sheet:
G0102
SCALE: 1/2" = V-0"
FLOOR PLAN KEY
EXISTING (E) CONSTRUCTION TO REMAIN
NEW (N) CONSTRUCTION
EGRESS NOTES
1. ALL DOORS MIN 32" WIDE PER IBC SECTION 1010.1.1. ALL DOORS ARE EXISTING PERMITTED UNDER
BLD2019-0530.
2. EXIT PATH LIGHTING SHALL COMPLY WITH IBC 1025
3. EXIT SIGNS SHALL COMPLY WITH IBC SECTION 10111
4. EVERY ASSEMBLY ROOM SHALL HAVE ITS OCCUPANT LOAD POSTED AT A CONSPICUOUS PLACE NEAR THE
MAIN EXITS PER IBC SECTION 1004.3
ACCESSIBILITY NOTES
1. BUILT IN WORK SURFACES AND DINING SURFACES SHALL COMPLY WITH ANSI 117.1 SECTION 305 & SECTION 902
2. ALL BUILT IN WORK SURFACES AND DINING SURFACES SHALL BE BETWEEN 28 AND 34 INCHES IN HEIGHT PER
ANSI 117.1 SECTION 902.4
3. ALL BUILT IN WORK SURFACES SHALL HAVE CLEAR FLOOR SPACE THAT IS POSITIONED FOR A FORWARD
APPROACH PER ANSI 117.1 SECTION 305.6
4. ALL BUILT IN SURFACES SHALL HAVE KNEE AND TOE CLEARANCE COMPLYING WITH ANSI 117.1 SECTION 305.4
5. ALL BUILT IN SERVICE COUNTERS SHALL COMPLY WITH ANSI 117.1 SECTION 305. & SECTION 904
6. ALL BUILT IN SERVICE COUNTERS SHALL BE A MAXIMUM OF 36 INCHES IN HEIGHT PER ANSI 117.1 SECTION
904.3.1
7. ALL BUILT IN SERVICE COUNTERS SHALL HAVE A MINIMUM OF 36 INCHES IN LENGTH AND 36 INCHES IN HEIGHT IF
ACCESSIBLE COUNTER SPACE VIA PARALLEL APPROACH, PER ANSI 117.1 SECTION 904.3.1
8. ALL BUILT IN SERVICE COUNTERS SHALL HAVE A MINIMUM OF 30 INCHES IN LENGTH AND 36 INCHES IN HEIGHT
OF ACCESSIBLE COUNTER SPACE VIA FORWARD APPROACH PER ANSI 117.1 SECTION 904.3.1
OCCUPANT LOAD CALCULATIONS
OCCUPANCY TYPE
OCCUPANCY KEY
AREA
FLOOR AREA PER
OCCUPANT
OCCUPANT LOAD
BUSINESS AREAS (SPRINKLERED)
NIA
150 GROSS
0
ASSEMBLY CONCENTRATED (BAR SEATING)
67 SQ FT
7 NET
10
ASSEMBLY UNCONCENTRATED (SEATING, EXTERIOR)
228 SQ FT
15 NET
16
ASSEMBLY FIXED SEATING (WITHOUT DIVIDING ARMS)
184"
18"
11
KITCHENS, COMMERCIAL
501 SQ FT
200 GROSS
3
ACCESSORY STORAGE
NIA
300 GROSS
0
TOTAL
40
OCCU NT LOAD P IBC 2018 CTION 1004 AND TABL 1004.1.2
S S 8..
BUILDING OCCUPANTS < 500 OCCUPANTS, > 50 OCCUPANTS - 2 EXITS NOT REQUIRED FOR B OCCUPANCY WITH LESS THAN 50 OCCUPANTS 1
2.EXITS PROVIDED PER BASE BUILDING PERMIT
D NMMER OF
L 01 II"IiR 7
MINIMUM ACCESSIBLE SEATS PROVIDED (5%): 2 - LEVEL 01 INTERIOR
C.2 -
EXTERIOR
PLAZA
D.4 -
E.5 -
FLOOR PLAN - LEVEL 01
SCALE: 1/4" = V-0"
C.2
- D.4
- E.5
N
•
1507 Belmont Ave, Suite 200
Seattle, Washington 98122
206.323.9932
1 12/28/22 Rev 1 - Permit corrections
No.: Date: Description:
Revisions:
RESUB
Mar 10 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
PERMIT SET
10/18/2022
Virtue Cellars
Tasting Room
558 MAIN STREET #104
EDMONDS, WA 98020
Project No.: 2137
Scale: As indicated
Sheet contents:
EGRESS AND CODE
INFORMATION
Sheet:
Aosol
SITE PLAN UNDERLAY FROM BASE BUILDING PERMIT, BLD2019-0530
1
1 ❑
1
I
I
I
I
I
I
I
I
I
Q
lha'om
1507 Belmont Ave, Suite 200
Seattle, Washington 98122
206.323.9932
- Description:
Revisions:
RESUB
Mar 10 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
F
PERMIT SET
10/18/2022
Virtue Cellars
Tasting Room
558 MAIN STREET #104
EDMONDS, WA 98020
Project No.: 2137
Scale: 1 /8" = V-0"
Sheet contents:
SITE PLAN
Sheet:
SITE PLAN
SCALE: 1/8" = V-0"
FLOOR PLAN KEY
EXISTING (E) CONSTRUCTION TO REMAIN
NEW (N) CONSTRUCTION
NOT IN SCOPE
FLOOR PLAN NOTES
1. VERIFY ALL DIMENSIONS IN FIELD.
2. PUBLIC HEALTH INSPECTION REQUIRED ON COMPLETION OF WORK PRIOR TO OPENING.
3. NO CHANGES WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL
4. GLAZING NOT MORE THAN 60" ABOVE THE FLOOR AND WITHIN A 24" ARC OF THE EDGE OF ANY SWINGING
DOOR OR GLAZING WITHIN 18" OF A FLOOR SURFACE MUST BE APPROVED SAFETY GLASS PER IBC SECTION
2406.3.6
5. EACH DOOR MUST HAVE AT LEAST AN 18" CLEAR FLOOR SPACE BEYOND THE STRIKE JAMB ON THE SWING
SIDE OF THE DOOR, MEASURED PARALLEL TO THE CLOSED DOOR POSITION. THE CLEAR AREA MUST EXTEND
OUT S PERPENDICULAR FROM THE CLOSED DOOR POSITION (PER IBC SECTION 1101.2.ICC/ANSI Al17.1-2003,
SECTION 404.2.3)
6. EACH DOOR WITH A LATCH AND CLOSER MUST HAVE AT LEAST A 12" CLEAR SPACE BEYOND THE STRIKE JAMB
(FLOOR TO 29" AFF) OPPOSITE THE SWING SIDE, MEASURED PARALLEL TO THE CLOSED POSITION. THE CLEAR
AREA MUST EXTEND OUT 4' PERPENDICULAR FROM THE CLOSED DOOR POSITION (PER IBC SECTION
1101.2.ICC/ANSI Al17.1-2003, SECTION 404.2.3)
7. DOOR HARDWARE MUST BE ACCESSIBLE (LEVER RATHER THAN A KNOB) FOR NEW OR RELOCATED DOORS
(PER IBC SECTION 1101.2.ICC/ANSI A117.1-2003, SECTION 404.2.6)
8. PRIOR TO ISSUANCE OF PERMIT A COPY OF THE SNOHOMISH COUNTY HEALTH DEPT. APPROVAL LETTER
SHALL BE PRESENTED TO THE CITY OF EDMONDS.
9. PER ICC/ANSI 117.1 SECTION 904.5.1, SELF-SERVICE SHELVES AND DISPENSING DEVICES FOR TABLEWARE,
DISHWARE, CONDIMENTS, FOOD AND BEVERAGES SHALL COMPLY WITH SECTION 308.
FOOD SERVICE NOTES
1. THIS PLAN IS PRIMARILY A GENERAL ARRANGEMENT OF EQUIPMENT PREPARED FROM AVAILABLE
INFORMATION. GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS AND SPECIFICATIONS
WITH DESIGNER, OWNER AND EQUIPMENT SUPPLIER
2. FOOD SERVICE OWNER TO SUPPLY HEALTH DEPARTMENT WITH LIST OF ALL MENU ITEMS TO BE SERVED AND
THEIR PREPARATION PROCEDURES
3. ALL EQUIPMENT TO BE ANSI ANS NSF CERTIFIED WHERE REQUIRED
4. ALL REFRIGERATION SHALL MEET OR EXCEED NSF #7 STANDARDS. EACH UNIT SHALL BE EQUIPPED WITH A
THERMOMETER THAT IS EASILY READABLE AND ACCURATE WITHIN ±2 DEGREES
5. THE USE OF SEALANTS MUST BE LISTED AS'APPROVED' BY THE NATIONAL SANITATION FOUNDATION (NSF)
UNDER STANDARD C-2 (SAFE FOR FOODSERVICE)
6. ALL OPENINGS IN CONSTRUCTION LESS THAN 2" WIDE SHALL BE SEALED TO WITHIN 1/32 OF AN INCH
7. OPENINGS AROUND SERVICE AND UTILITY LINES SHOULD BE CLOSED AS FAR AS POSSIBLE WITH COLLARS,
GROMMETS AND FLEXIBLE FORM GASKETS. SEALANTS MAY NOT BE USED TO SEAL SERVICE OR UTILITY LINES
TO WALLS OR ADJACENT SURFACES
8. EQUIPMENT BLACKSPLASHES SHALL BE SEALED TO WALLS WITH NSF APPROVED CLEAR SILICONE, WHERE
APPLICABLE
9. ALL CUTTING BOARDS AND WORK SURFACE SHALL BE OF NON -WOOD CONSTRUCTION
10. COUNTER -TOP EQUIPMENT NOT READILY MOVABLE WEIGHING IN EXCESS OF 60LBS. SHALL BE EQUIPPED
WITH 4" LEGS
11. HANDWASHING FACILITIES ARE REQUIRED FOR FOOD PREPERATION, SERVING, COOKING, AND/OR UTENSIL
WASHING AREAS
12. ALL LIGHTING OVER FOOD PREPARATION AREAS MUST BE SHIELDED OR APPROVED SAFETY COATED
13. ALL UTILITY LINES TO BE BURIED WHERE POSSIBLE. NO UNNECESSARILY EXPOSED LINES ACCEPTED
14. VACUUM BREAKERS AND BACKFLOW PREVENTION DEVICES TO BE PROVIDED BY PLUMBING CONTRACTOR
AND TO BE A MINIMUM OF 6" ABOVE THE FLOOD LEVEL RIM WITH NO SHUT-OFF DEVICES BEYOND THE
DISCHARGE OF THE VACUUM BREAKER
15. OPERATOR TO PROVIDE SOAP AND TOWEL DISPENSERS AT ALL HAND SINK LOCATIONS PRIOR TO HEALTH
DEPT INSPECTION
16. MINIMUM HOT WATER TEMPERATURE AT ALL HAND SINKS TO BE 100 DEGREES THROUGH A MIXING VALVE
17. ALL FLOORS, WALL, AND CEILINGS MUST HAVE A SMOOTH AND EASILY CLEANABLE SURFACE
18. FLOOR/WALL JUNCTIONS TO HAVE A COVED BASE. 6" HIGH MINIMUM
19. ALL WOOD SURFACES TO BE SEALED TO CREATE A SMOOTH CLEANABLE SURFACE
20. SNEEZE GUARD DIMENSIONS TO COMPLY WITH NSF/ANSI 2-2014, SECTION 5.35
NO
22. PRIOR TO ISSUANCE OF PERMIT A COPY OF THE SNOHOMISH COUNTY HEALTH DEPT. APPROVAL LETTER
SHALL BE-PRESENTEQTO THE CITY OF EDMONDS - - - -
TrPER ICC7 R M 117.1 SrMTON 904374"SELF-SERT"i SHELVITKND DISPTMTTNG DEVItTS'FOR TA711MARE,
DISHWARE, CONDIMENTS, FOOD AND BEVERAGES SHALL COMPLY WITH SECTION 308.
ROOM FINISH SCHEDULE
ROOM
REF.
NAME
WALL FINISH
CEILING FINISH
FLOOR FINISH
BASE FINISH
COUNTER
N/A
101 SEATING GWB, PAINT (E) (E) CONIC.; GRIND AND SEAL 1/2x4 WOOD BASE; PAINTED
102
BAR
METAL PANEL ON CUSTOMER SIDE OF
(E)
(E) CONC. ; GRIND AND SEAL
COVED RUBBER BASE ON SERVICE SIDE, 6X6" METAL
SOLID WOOD BAR TOP; MILESI FINISH
CASEWORK, FRP ON SERVICE SIDE
ANGLE ON CUSTOMER SIDE
103
BOH
GWB; SS PANEL ABOVE COUNTER
(E) CEILING;COVER PROVIDED FOR EQUIP ABOV
(E) CONC. ; GRIND AND SEAL
RUBBER COVE BASE
PLAM COUNTERTOP
EQUIPMENT SCHEDULE
MARK
QTY
DESCRIPTION
MANUF.
MODEL
("XX", "TBD" OR "SIM. TO BE DETERMINED BY KC.)
VOLTS
AMPS
HP
HOT
COLD
DIRECT
INDIRECT
NOTES
1
2
UNDER COUNTER BACK BAR BAR REFRIDGERATION
GLASSTENDER OR SIM.
C2FB
120 V
3.5
2
1
DUMP SINK
REGENCY
9" X 9" X 5" 18 GAUGE SS DROP IN SINK W/ 8" FAUCET
1/2"
1/2"
1 1/2"
3
1
HAND SINK
REGENCY
9" X 9" X 5" 18 GAUGE SS DROP IN SINK W/ 8" FAUCET
1/2"
1/2"
1 1/2"
4
1
UNDER COUNTER GLASS WASHER
AUTOCLOR OR SIM
U-34
115 V
20
1
1/2"
1 1/2"
5
5
3 COMP SINK
REGENCY
10" X 14" X10" 16 GAUGE SS SINK WITH 10" FAUCET
1/2"
1/2"
1 1/2"
6
1
UPRIGHT DOUBLE DOOR REFRIFGERATOR
TRUE
T-35FHC
115 V
9.6
1
C.2 -
I-
w
w
co
O
H
PLAZA
D.4 -
E.5 -
(E) FC
(E)
FLOOR PLAN - LEVEL 01
SCALE: 1/4" = V-0"
- C.2
- D.4
- E.5
•
1507 Belmont Ave, Suite 200
Seattle, Washington 98122
206.32-3.9932
1 12128122 Rev 1 - Permit corrections
No.: 1111181PI1111i Description:
Revisions:
RESUB
Mar 10 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
PERMIT SET
10/18/2022
Virtue Cellars
Tasting Room
558 MAIN STREET #104
EDMONDS, WA 98020
Project No.: 2137
Scale: As indicated
Sheet contents:
FLOOR PLAN
Sheet:
REFLECTED CEILING PLAN KEY
OO CAN FIXTURE, CEILING MOUNT OR RECESSED
FLUORESCENT
PENDANT
\7 Z_� \7 TRACK LIGHTING
x SCONCE
CEILING MATERIAL
CEILING HEIGHT, AFF
REFLECTED CEILING PLAN NOTES
1. ENSURE ALL SURFACES DESIGNATED TO RECEIVE FINISHES ARE CLEAN, TRUE & FREE OF IRREGULARITIES.
DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.
2. DEVICE COVER PLATES (ELEC, DATA, SWITCH, CARD READER, ETC) TO RECEIVE FACTORY FINISH MOST
SIMILAR IN COLOR TO SURFACE OF APPLICATION, SUBMIT LOCATION PLAN FOR ARCHITECT'S APPROVAL.
3. GC TO VERIFY DIMS AND FIELD CONDITIONS, CONTACT ARCHITECT IMMEDIATELY TO DISCUSS CONFLICTS,
PROBLEMS, OR CONCERNS.
4. PROVIDE CEILING ACCESS AS REQ'D FOR EQUIPMENT AND SYSTEM MAINTENANCE, AND MATCH ADJACENT
CEILING FINISH, UON.
5. ELECTRICAL UNDER SEPARATE PERMIT -- SEE DRAWINGS FOR EMERGENCY LIGHTING LOCATIONS, FIXTURE
TYPES, LIGHTING CIRCUITING AND CONTROL SYSTEM DOCUMENTATION AND CALCULATIONS.
6. FIXTURE MOUNTING HEIGHTS TO BE BOTTOM OF THE FIXTURE, LION. VERIFY IN FIELD ALL FIXTURE MOUNTING
HEIGHTS W/ARCHITECT.
7. SEE INTERIOR ELEVATIONS FOR HEIGHTS OF WALL MOUNTED FIXTURES.
8. LOCATE FIXTURES AS SHOWN IN CEILING GRID. IF GRID LOCATION DIFFERS FROM WHAT IS SHOWN ON
DRAWINGS, CONTACT ARCHITECT BEFORE INSTALLATION.
9. IN ROOMS WITH ACOUSTICAL CEILING TILE, CENTER THE GRID IN ALL DIRECTIONS, UON.
10. PROVIDE EXIT AND EMERGENCY LIGHTING PER CODE. CENTER ALL EXIT SIGNS, SMOKE DETECTORS, ETC,
THE CENTERLINE OF CORRIDORS AND CENTERLINE OF LIGHT FIXTURES, UON.
11. FINISH HVAC DIFFUSERS, GRILLES, ETC, TO MATCH ADJACENT FINISH, UON.
12. PROVIDE SPRINKLER HEAD LOCATIONS FOR ARCHITECT'S REVIEW PRIOR TO ANY INSTALLATION.
13. PROVIDE CONCEALED SPRINKLER HEADS WITH CAPS FACTORY PAINTED TO MATCH ADJACENT FINISH IN A
DRYWALL CEILINGS. LOCATE HEADS TO ALIGN WITH LIGHT FIXTURES, LION.
14. NO COMBUSTIBLE MATERIAL ALLOWED ABOVE CEILING.
15. FIXTURES THAT APPEAR CENTERED BETWEEN BEAMS OR GRIDLINES ARE CENTERED.
16. ALL DIMENSIONS ARE TO CENTERLINE OF LIGHT FIXTURES, LION.
MARK
L01
QTY
TYPE
NOT USED
MANUF.
LIGHTING FIXTURE SCHEDULE
MODEL FINISH DIMMING COLOR TEMP.
("XX", "TBD" OR "SIM. TO BE DETERMINED BY ELEC.)
MOUNTING HEIGHT
B.O. FIXTURE
NOTES
L02A
9
PENDANT
LIGHTOLIER
PENDANT CABLE C2CPSDL
BLACK
Y
2700K
1V-0" AFF
DIMMING NOT REQ'D IN BOH
L03
1
CHANDELIER
LYFAIRS
BRANCH CRYSTAL CHANDELIER DD001-435-01
PER MANUFACTURER
N
2700K
6-2" AFF
FOIC
L04
4
SCONCE
RBW
RIPPLE SCONCE
N
2700K
90 CRI MIN. 3000K ACCPETED
L05
NOT USED
L06
—42 LF
LED STRIP LIGHT
LUMINII OR SIM.
KSW-PER ELEV-SO-27K-F-FC-BZ-XX-XX-XX
BRONZE
Y
2700K
90 CRI MIN. WET RATING NOT REQ'D, PROVIDE ALL PARTS FOR A COMPLETE INSTALL, ALTS ACCEPTED
L07
—50 LF
TRACK LIGHT
JUNO
T TRACK PROFILE W/ R606L-XX-27K-90CRI-PDIM-FL
BLACK
Y
2700K
(8) HEADS TOTAL. 90 CRI MIN. PROVIDE ALL PARTS FOR A COMPLETE INSTALL, ALTS ACCEPTED
•
1507 Belmont Ave, Suite 200
Seattle, Washington 98122
206.323.9932
1 12/28/22 Rev 1 - Permit corrections
No.: Date: Description:
Revisions:
RESUB
Mar 10 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
PERMIT SET
10/18/2022
Virtue Cellars
Tasting Room
558 MAIN STREET #104
EDMONDS, WA 98020
Project No.: 2137
Scale: As indicated
Sheet contents:
OVERALL RCP -
LEVEL 01
Sheet:
LEVEL 01 -REFLECTED CEILING PLAN
SCALE: 1/2" = V-0"
N