Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD ENG FIR PLN_RESUB1 BLD2022-1217+Architectural_Plan
JOHNNY MO'S PIZZERIA EDMONDS. WA SEPT. 13, 2022 - PERMIT SET ed States Kahlo's� C Postal Service North Sound Center Edmonds Eanona. st © r7a ss'/ Municipal Court t %la/n / o Rick Sieves' Europe Corpus Christi Chapel O © 0 Run for Good Racing Company ���� hgc Salt and Iron Charcoal-1,-SSS o ®Edmonds "I si m ig c Summer Market .c `� ® O'Malley Brothers INC9 WORKHORSE Chamerelle Rusty Pelican Cafe eeae3stss Edmonds yo �`� y} Historical Museum / Studio ProminenceQ z Edmonds Parks, uece st ©Coastal Community Bank Recreation & Cultural... Edmonds Ferry Terminal ® Main St © Main St 9 t QEdmonds Landing B Booth s MARKET Edmonds SIT Edmonds Arts Festival Assisted Living QBeresf PLLC Lawyers yers < seafood 55 Q y 9Red Twig Cafe and Bakery p v Main Street Kids OPreschool& Child Care... ® Dayton St ® © Dayion St Dayton St IS Dayton St 13 2 WesterlyQ - Salish Sea Brewing _ > Co & Restaurant Art Works Edmonds w w Cafe Louvree p anarinCanarino Gelato Caffe m v .55 Augustus Bukowski-Cardinal... Maple st Maple St /w A Maple sl VICINITY MAP MAIN STREET GENERAL NOTES 1. ALL WORK IS TO BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE SEATTLE BUILDING, MECHANICAL, ELECTRICAL AND PLUMBING CODES, AND ALL APPLICABLE CODES AND ORDINANCES. IN THE EVENT OF CONFLICT BETWEEN PERTINENT CODES AND REGULATIONS AND THE REQUIREMENTS OF THE REFERENCED STANDARDS OF THESE NOTES, THE PROVISIONS OF THE MORE STRINGENT SHALL GOVERN. 2. THE CONTRACTOR SHALL VERIFY ALL THE INFORMATION IN THE DRAWINGS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCY PRIOR TO ORDERING MATERIALS OR COMMENCING WITH WORK. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL NOTIFY THE ARCHITECT IF THERE ARE ANY OBSERVED DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS. 3. THE CONTRACTOR SHALL PROVIDE ALL MATERIAL, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE THE WORK EXCEPT FOR THOSE ITEMS SHOWN AS N.I.C. (NOT IN CONTRACT). IF HIDDEN OR UNUSUAL "LANS M UST BE SITUATIONS ARE ENCOUNTERED DURING CONSTRUCTION WHICH 0!! ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & I N D U S T g tESZ' -� D 558 MAIN STREET i EAST BUILDING I WEST BUILDING AREA OF WORK i UNDER SEPARATE PERMIT 21353 SF i T ENTRY I O O O O O O O I ALLEY------------------------------------------------------------------------------------------- I SITE PLAN AO.00J SCALE .1 /16 11- 011 11-15-2022 PLAN REVIEW NOTES: APPROVED DEFERRED SUBMITALLS 1. FIRE SPRINKLER 2. FIRE ALARM 3. HOOD SUPPRESSION IF TYPE 1 HOOD. DFM BURT Approved DFM ChrL'sg�crt South County Fire Date: 11 /15/2022 Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. REVISIONS DATE PAGES CHANGES REV1 REV2 REVS REW REV5 COULD NOT HAVE BEEN FORSEEN PRIOR TO CONSTRUCTION, NOTIFY THE ARCHITECT BEFORE PROCCEEDING WITH THE WORK. 4. THE CONTRACTOR SHALL NOT ENCUMBER ANY PUBLIC OR PRIVATE PROPERTY OTHER THAN THE SITE WITHOUT ENCROACHMENT PERMITS OR WRITTEN PERMISSION FROM THE PROPERTY OWNERS. 5. THE CONTRACTOR SHALL PROVIDE FENCING, BARRICADES, WARNING SIGNS/SIGNALS OR OTHER PROTECTIVE MEASURES AS NEEDED TO PROVIDE FOR THE PUBLIC'S SAFETY. 6. THE CONTRACTOR SHALL SCHEDULE AND COORDINATE ALL INSPECTIONS AND AT THE END OF THE WORK PROVIDE THE OWNER WITH ALL THE ORIGINAL SIGNED DOCUMENTS FROM ANY INSPECTING ENTITY. 7. TYPICAL DETAILS AND NOTES SHALL APPLY UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE. DETAILS NOT FULLY SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS SHOWN FOR SIMILAR CONDITIONS. DIMENSIONS TAKE PRECEDENCE OVER SCALE SHOWN ON DRAWINGS. SCALING DRAWINGS TO DETERMINE DIMENSIONS IS NOT VALID. 8. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DESIGN AND PROVIDE SHORING, BRACING, FORMWORK, ETC., AS REQUIRED TO PROTECT LIFE AND PROPERTY. 9. JOB COPIES OF THE BUILDING & PERMITS SHALL BE ON -SITE DURING INSPECTIONS. 10. MECHANICAL, ELECTRICAL, AND TELEPHONE/DATA WORK SHALL BE PERFORMED AS DESIGN/BUILD SUB -CONTRACTS, EACH SUB -CONTRACTOR SHALL SECURE ALL PERMITS AS REQUIRED FOR THEIR SCOPE OF WORK. 11. PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK, THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE CONTRACT DOCUMENTS, OWNER -PROVIDED INFORMATION AND SITE CONDITIONS, INCLUDING TAKING FIELD MEASUREMENTS. 12. DIMENSIONS OF EXISTING CONDITIONS ARE FROM DRAWINGS BY OTHERS. ARCHITECT BEARS NO RESPONSIBILITY FOR ACCURACY OF W THE EXISTING AS -BUILT DRAWINGS. DIMENSIONS ARE TO FACE OF > INTERIOR FINISH, EXISTING WALL, OR CENTERLINE OF NEW INTERIOR Q WALL, UNLESS OTHERWISE NOTED. NOTIFY ARCHITECT OF ANY = DISCREPANCIES FOUND. DO NOT SCALE DRAWINGS. 13. REPETITIVE ELEMENTS: TYPICAL WALL SECTIONS, FINISHES AND 1110 DETAILS ARE NOT INDICATED EVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS AND SECTIONS. REFER TO DETAILED DRAWINGS. CONTRACTOR TO PROVIDE AS IF DRAWN IN FULL EVERYWHERE 14. THE CONTRACTOR SHALL CONSULT THE PLANS OF ALL TRADES FOR OPENINGS THROUGH SLABS, WALLS, CEILINGS AND ROOFS FOR DUCTS, PIPES, CONDUIT, CABINETS AND EQUIPMENT, AND SHALL VERIFY THE SIZES AND LOCATIONS WITH SUBCONTRACTORS. 15. ABBREVIATIONS: THROUGHOUT THE PLANS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE ARCHITECT WILL DEFINE THE INTENT OF ANY ABBREVIATION IN QUESTION. ABBREVIATIONS OR PARTIAL CODE SECTIONS NOTED ON THIS PLAN AND PLAN REVIEW LIST ARE INTENDED TO INDICATE THE NATURE OF THE PLANS OR GIVE ADDITIONAL INFORMATION. THE FULL TEXT OF THE CODE ALWAYS APPLIES. ENGINEERING DIVISION APPROVED AS NOTED 11 /14/2022 ***ALL MATERIALS, EQUIPMENTS, CONSTRUCTION VEHICLES, ETC TO BE LOCATED ON PRIVATE PROPERTY. NO APPROVAL FOR USE OF THE CITY RIGHT-OF-WAY.*** DEFERRED SUBMITTALS MECHANICAL PLUMBING ELECTRICAL FIRE SPRINKLER (MODIFICATIONS IF NEEDED) FIRE ALARM ADDRESS 550 MAIN STREET, SEATTLE, WA 98020 PROPERTY OWNER: MIKE MCMURRAY, SEATTLE-SNOHOMISH MILL COMPANY, INC 533 5TH AVE S EDMONDS, WA 98020 GECK08080@GMAIL.COM (425) 263-2474 PROPERTY TAX ACCOUNT NUMBER 004342-120-015-00 AND 004342-120-017-00 (BEING COMBINED UNDER SEPARATE APPLICATION SITE AREA LOT SIZE 19,789 GSF LEGAL DESCRIPTION LOTS 15 AND 16, BLOCK 120, CITY OF EDMONDS ADDITION, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 2 OF PLATS, PAGE 39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. AND; LOTS 17, 18, 19 AND 20, BLOCK 120, CITY OF EDMONDS ADDITION, ACCORDING TO THE PLATE THEREOF, RECORDED ION VOLUME 2 OF PLATS, PAGE 39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. ZONING BD1 USE - OCCUPANCY EXISTING USE OF SPACE: "A3" EVENT SPACE PROPOSED USE OF SPACE- OFFICE - "A2" RESTAURANT CONSTRUCTION TYPE TYPE VB SPRINKLERED (UNDER PREVIOUS PERMIT) F.111 V we] IW1T[61VEl4 RESTAURANT- 2,356 SF EXISTING DECKS/PATIOS: WEST- 500 SF NORTH- 256 SF PROJECT DESCRIPTION FIRST TIME BUILD OUT OF NEW TENANT SPACE. SPLIT-LEVEL WITH EXISTING ELEVATOR SERVICE. PROPOSED RESTAURANT WITH KITCHEN AREA, BAR AREA, SERVICE AREA, TWO EXISTING PATIO AREAS FOR SEATING/DRINKING. BATHROOM FOR PATRONS WILL BE ON LOWER LEVEL AND COMPLETED AS PART OF SHELL & CORE PERMIT( BLD2019-0529 & 0530) GOVERNING CODES 2018 INTERNATIONAL BUILDING CODE (IBC) WITH STATE AMENDMENTS 2018 INTERNATIONAL EXISTING BUILDING CODE WITH STATE AMENDMENTS 2018 INTERNATIONAL MECHANICAL CODE (INCLUDING INTERNATIONAL FUEL GAS CODE) WITH STATE AMENDMENTS 2018 INTERNATIONAL FIRE CODE WITH STATE AMENDMENTS 2018 UNIFORM PLUMBING CODE (IBC) WITH STATE AMENDMENTS 2018 WASHINGTON STATE ENERGY CODE (WAC 51-11) 2018 INTERNATIONAL PROPERTY MAINTENANCE CODE EDMONDS COMMUNITY DEVELOPMENT CODE 2014 NATIONAL ELECTRICAL CODE CONTACTS BUILDING OWNER MIKE MCMURRAY, SEATTLE-SNOHOMISH MILL COMPANY, INC 533 5TH AVE S EDMONDS, WA 98020 GECK08080@GMAIL.COM (425) 263-2474 LESSEE: JOHNNY MO'S PIZZERIA JOHN GENNA 3227 FUHRMAN ACE E, #100 SEATTLE WA, PHONE: 206-822-6272 EMAIL: JOHNNY@JOHNNYMOS.COM ARCHITECT: URBAL ARCHITECTURE 1938 FAIRVIEW AVE E, SUITE 100 SEATTLE, WA 98102 P 206-676-5645 CONTACT: CHAD LORENTZ CHADL@URBALARCHITECTURE.COM DRAWING INDEX ARCHITECTURAL A0.00 COVER SHEET A0.01 ABBREVIATIONS & LEGEND A0.10 CODE ANALYSIS -OCCUPANCY & EXITING I A2.00 FLOOR PLAN- UPPER FLOOR A2.01 FLOOR PLAN- LOWER FLOOR (FOR REFERENCE ONLY) A3.00 REFLECTING CEILING PLAN A4.00 ROOF PLAN A5.00 EXTERIOR ELEVATIONS A6.00 BUILDING SECTIONS A7.00 INTERIOR ELEVATIONS A7.01 INTERIOR ELEVATIONS A7.02 KITCHEN ELEVATIONS A8.00 RESTROOM ELEVATION A8.01 RESTROOM ELEVATION A9.00 WALL DETAILS A9.01 CASEWORK DETAILS A10.00 FINISH PLAN/SCHEDULE KITCHEN K1 EQUIPMENT PLAN K2 EQUIPMENT SCHEDULE K3 ELECTRICAL ROUGH IN PLAN K4 MECHANICAL ROUGH IN PLAN Sep�#e permits reW�T BACKING PLAN Plumbing Mechanical Type 1 hood Fire Suppression Separate approvals from Snohomish County Health District required. CONTRACTOR WESTERN VENTURES CONSTRUCTION RYAN CARLISLE PO BOX 298 MOUNTLAKE TERRACE, WA 98043 PHONE: 425-640-5050 EMAIL: INFO@WESTERNVENTU RES.COM LAty UT tamonas Building Department --------------------------------------------- Work TENANT IMPROVEMENT ----------------------------------------- r------------------------------------------------------- Address' 550 MAIN ST Owner JOHNNY MO'S PIZZA Approved Date Elrl.fi CAA-rfe r r Building Official 11 /14/2022 Permit Number; BLD2022-1217 CONSTRUCTION TYPE VB OCCUPANCY GROUP A-2 OCCUPANT LOAD 121 APPROVED BY PLANNING 4lAM� Oct 07 2022 ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. ORE "I Z STATE OF W SHI TON JOHNNY MO'S 558 MAIN STREET EDMONDS, WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 CORK RESPONSE #1 10.31.2022 COVER SHEET DATE SCALE DRAWN ETK & FO JOB # 22-037 )yrigl ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used In whole or in part without the written authorization of Urbal Architecture, PLLC. RESUB Nov 01 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GENERAL ABBREVIATIONS: SYMBOLS LEGEND URBAL GENERAL ABBREVIATIONS ANCHOR BOLT AB ABV ABOVE ACOUS ACOUSTICAL ACT ACOUSTICAL CEILING TILE AD AREA DRAIN ADDL ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR AG ALUMINUM & GLASS ALC ALUMINUM CLAD ALT ALTERNATE ALUM ALUMINUM ALV ALUMINUM CLAD VINYL ALW ALUMINUM CLAD WOOD AN ANODIZED APPROX APPROXIMATE APT APARTMENT ARCH ARCHITECTURAL AS ALUMINUM STOREFRONT AVG AVERAGE AWN AWNING B.O. BOTTOM OF BA BATH BC BOTTOM OF CURB BD BOARD BLW BELOW BITUM BITUMINOUS BLDG BUILDING BLKG BLOCKING BLW BELOW BM BEAM BSMT BASEMENT B/T BETWEEN BUR BUILT-UP ROOFING BYD BEYOND C CASEMENT C&G CURB AND GUTTER CAB CABINET CB CATCH BASIN CC CENTER TO CENTER CIP CAST IN PLACE CIRC CIRCULATION CL CENTERLINE CLG CEILING CLR CLEAR CLR FIN CLEAR FINISH CMU CONCRETE MASONRY UNIT CO CLEAN OUT COL COLUMN CONIC CONCRETE CONT CONTINUOUS CORR CORRIDOR CPT CARPET CT CERAMIC TILE CTB CERAMIC TILE BASE CTR CENTER CW COLD WATER CWG CLEAR WIRED GLASS CVG CLEAR VERTICAL GRAIN D DRYER DBL DOUBLE DE DELAYED EGRESS DEMO DEMOLITION DH DOUBLE HUNG DIA DIAMETER DR DOOR(S) DS DOWNSPOUT DW DISHWASHER DWG DRAWING EA EACH EB EXPANSION BOLT EF EACH FACE EL ELEVATION ELEC ELECTRICAL) ELEV ELEVATOR EMER EMERGENCY ENCL ENCLOSURE EP ELECTRICAL PANEL EQ EQUAL EQUIP EQUIPMENT ESCAL ESCALATOR ESMT EASEMENT EXH EXHAUST EXST EXISTING EXT EXTERIOR F FIXED FA FIRE ALARM FAF FACTORY APPLIED FINISH FAP FIRE ALARM CONTROL PANEL FAPB FIRE ALARM PULL BOX FB FLAT BAR FBG FIBERGLASS FC FIBER CEMENT FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FDN FOUNDATION FDR FRENCH DOORS FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FIN FINISH FL FLUSH FLR FLOOR F.O.C. FACE OF CONCRETE F.O.F. FACE OF FINISH F.O.M. FACE OF MASONRY F.O.S. FACE OF STUDS FPL FIREPLACE FIR FRAMING FRP FIBER REINFORCED PLASTIC FRT FIRE RETARDANT FRTW FIRE RETARDANT TREATED WOOD FT FOOT (OR FEET) FTG FOOTING FURR FURRING FUT FUTURE GA GAUGE GALV GALVANIZED GAR GARAGE GB GRAB BAR GC GENERAL CONTRACTOR GFRC GLASS FIBER REINFORCED CONCRETE GL GLASS GLB GLU-LAMINATED BEAM GLZ GLAZING GND GROUND GS GARAGE SECTIONAL DOOR GSF GROSS SQUARE FEET GWB GYPSUM WALL BOARD HB HOSE BIB HC HOLLOW CORE HCW HOLLOW CORE WOOD HD HEAD HDO HIGH DENSITY OVERLAY HDWD HARDWOOD HM HOLLOW METAL HORIZ HORIZONTAL HVAC HEATING VENTILATION AIR CONDITIONING HW HOT WATER HYDR HYDRAULIC IBC INTERNATIONAL BUILDING CODE ID INTERIOR DESIGN IIC IMPACT ISOLATION CLASS IN INCH(ES) INCL INCLUDING INS INSULATION INT INTERIOR JAN JANITOR KB KEY BOX / KNOX BOX KID KNOCK DOWN KIT KITCHEN KO KNOCK OUT KW KILOWATTS LAM LAMINATE LAV LAVATORY LB POUND LF LINEAR FEET LOC LOCATION LTG LIGHTING LOW-E LOW GLAZING LVR LOUVER MAINT MAINTENANCE MAS MASONRY MATL MATERIAL MAX MAXIMUM MB MACHINE BOLT MED MEDICINE MDF MEDIUM DENSITY FIBERBOARD MDO MEDIUM DENSITY OVERLAY MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEZZ MEZZANINE MFR MANUFACTURER MGR MANAGER MH MANHOLE MIN MINIMUM MIRR MIRROR MISC MISCELLANEOUS MK MARK MP METAL, PAINTED MTD MOUNTED MTL METAL MULL MULLION NIC NOT IN CONTRACT NOM NOMINAL NSF NET SQUARE FEET NTS NOT TO SCALE 0/ OVER CA OVERALL OC ON CENTER OD OVERFLOW ROOF DRAIN OFCI OWNER FURNISHED / CONTRACTOR INSTALLED OFF OFFICE OFOI OWNER FURNISHED / OWNER INSTALLED OPP OPPOSITE OVHD OVERHEAD OZ OUNCE PB PARTICLE BOARD PC PRECAST CONCRETE PCF POUNDS PER CUBIC FOOD PED PEDESTAL PERF PERFORATED PERP PERPENDICULAR PIC PICTURE (WINDOW) PIV POST INDICATOR VALV PL PROPERTY LINE PLAM PLASTIC LAMINATE PLAS PLASTER PLYWD PLYWOOD POLY POLYETHYLENE PREFAB PREFABRICATED PREFIN PREFINISHED PRKG PARKING PROP PROPERTY PRV PRESSURE REDUCING VALVE PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PNT POINT PT PRESSURE TREATED PTD PAINTED PVC POLYVINYL CHLORIDE PVMT PAVEMENT QTY QUANTITY R RISER RA RETURN AIR RAID RADIUS RC RESILIENT CHANNEL RCP REFLECTED CEILING PLAN RD ROOF DRAIN REFR REFRIGERATOR REINF REINFORCE REQD REQUIRE RESIL RESILIENT RL (INTERIOR) RELITE RSTRM RESTROOM RET RETAINING RO ROUGH OPENING ROW RIGHT OF WAY RWL RAIN WATER LEADER SA SUPPLY AIR SAF SAFETY LAMINATED SC SOLID CORE SCW SOLID CORE WOOD SECT SECTION SH SINGLE HUNG SHT SHEET SHTHG SHEATHING SIM SIMILAR SL SLIDING SLID SLIDING DOOR SOG SLAB ON GRADE SP STANDPIPE SPG SPANDREL GLAZING SPEC SPECIFICATION SSTL STAINLESS STEEL ST STAINED STA STATION STAG STAGGERED STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STM STEEL CHANNEL MEMBER STOR STORAGE STRUCT STRUCTURE (STRUCTURAL) SUSP SUSPENDED SV SHEET VINYL SYST SYSTEM T TEMPERED T&G TONGUE AND GROOVE T.O.B. TOP OF BEAM T.O.C. TOP OF CURB TD TRENCH DRAIN TEMP TEMPORARY T.O.F. TOP OF FOOTING T.O.F.F. TOP OF FINISH FLOOR THK THICK(NESS) T.O.J. TOP OF JOIST T.O. TOP OF T.O.C. TOP OF CONCRETE T.O.P. TOP OF PARAPET T.O.W. TOP OF WALL TOPO TOPOGRAPHIC TP TOP OF PAVEMENT TR TREAD TRANS TRANSLUCENT GLAZING TRTD TREATED TSTAT THERMOSTAT TV TELEVISION TYP TYPICAL UNEX UNEXCAVATED UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE UTIL UTILITIY (OR UTILITIES) VB VINYL BASE VCT VINYL COMPOSITION TILE VEH VEHICLE VENT VENTILATION VERT VERTICAL VEST VESTIBULE VG VERTICAL GRAIN V VINYL VIF VERIFY IN FIELD VNF VINYL NAIL -FLANGE VP VENEER PLASTER VTR VENT THROUGH ROOF W WASHING MACHINE WC WATER CLOSET WD WOOD W/D WASHER/DRYER WIG WOOD & GLASS WGL WIRE GLASS WH WATER HEATER W/0 WITHOUT W.P. WORKING POINT WP WATER PROOF WRB WATR-RESISTIVE BARRIER WDW I WINDOW(S) VIEW REFERENCES OBJECT REFERENCES BUILDING SECTION ROOM TAG DETAIL # ON SHEET ROOM NAME SIM ROOM NAME 1 101 ROOM # A10 150 SF SHEET # ROOM (NET) SQUARE FOOTAGE DETAIL CUT DOOR TAG DETAIL # ON SHEET SIM DOOR #; REFER TO 1 A10 DOOR SCHEDULE SHEET # ENLARGED PLAN OR DETAIL WINDOW TAG DETAIL # ON SHEET SIM �_ --- 1 WINDOW #; REFER TO it WINDOW SCHEDULE A101 > -Aav SHEET # BUILDING ELEVATION MATERIAL TAG 1 DETAIL #, TYP MATERIAL PER LEGEND 1 A101 1 PTA MTRL SHEET # PAINT COLOR PER LEGEND 1 INTERIOR ELEVATION WALL TAG 1 DETAIL #, TYP WALL TYPE *REFER TO SHEET A8.00 1 A101 1 FOR WALL ASSEMBLIES E SHEET # 1 HIDDEN ELEVATION ROOF/FLOOR/CEILING TAG DETAIL # ON SHEET X ROOF/ FLOOR/ CEILING IM 1 A101 TYPE SHEET # CODE COMPLIANT EXIT SIGN REVISION TAG WITH EMERGENCY LIGHTING EXIT 1 REVISION # DIRECTIONAL CODE COMPLIANT EXIT SIGN WITH EMERGENCY LIGHTING FEC CODE COMPLIANT FIRE EXTINGUISHER EXIT EXIT LOAD xx \Lx_Xxj EXIT CAPACITY 0.3" PER OCCUPANT FOR STAIRS 0.2" PER OCCUPANT FOR ALL OTHER COMPONENTS EXISTING WALLS & PARTITIONS (TO REMAIN) NEW PARTITION (TO MATCH HEIGHT OF EXISTING PARTITIONS) ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. ORE TZ STATE OF W SHI TON RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MO'S PIZZERIA 550 MAIN STREET EDMONDS,. WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 ABBREVS. LEGEND DATE SCALE DRAWN ETK & FO JOB # 22-037 ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used In whole or in part without the written authorization of Urbal Architecture, PLLC. A0001 OCCUPANCY CALCULATION: AREA: 2,344 GSF EXISTING USE: BUSINESS "A3" VACANT EVENT SPACE PROPOSED USE: BUSINESS "A2" RESTAURANT OCCUPANT LOAD FACTORS: 200 SF/ OCCUPANT BUSINESS 200 SF/OCCUPANT KITCHEN 15 SF/OCCUPANT ASSEMBLY NON -CONCENTRATED CONF. ROOM 300SF/OCCUPANT STORAGE • B OCCUPANCY: BAR 103: 162 SF = 1 OCCUPANTS SERVICE 101: 64 SF = 1 OCCUPANTS KITCHEN 104: 822 SF = 5 OCCUPANTS • A-2 OCCUPANCY DINING 102: 1101 SF: =74 OCCUPANTS PATIO 2: 222 SF: =15 OCCUPANTS PATIO 1: 455 SF =31 OCCUPANTS • S-1OCCUPANCY WIC 105: 104 SF = 1 OCCUPANTS TOTAL OCCUPANTS: 128 OCCUPANTS NUMBER OF EXITS PROVIDED FROM UPPER FLOOR: 2 EXIT NUMBER OF EGRESS STAIRS PROVIDED: 2 EGRESS LEGEND CLEAR PATH TRAVEL EXIT EXIT SIGNS E EMERGENCY ILLUMINATION FIXTURE PER IBC 1006.2 FEC FIRE EXTINGUISHER ADA SEATING CALCULATION DINING ZONE SEAT 5% OF SEAT (REQUIRED PROVIDED DINING 102 68 3.4 4 4 PATIO 106 28 1.4 2 2 PATIO 107 8 0.4 1 1 PLUMBING CALCULATION OCCUPANTS DINING 128 DIVIDE BY 2 64 DIVIDE BY 75 0.85 TOTAL 0.85 1 PER REQUIRED 1 PER PROVIDED PATIO 107 (1/15) 455 SF 131 OCC I 4 TOP 4 TOP 30" X 60" - 30" X 60" 4 TOP 4 TOP 30" X 60" 30" X 60" ATIO 1 107 4 TOP 30" X 60" 4TOP 30" X 60" LJ t EXIT PATH - E L DOWN TO GR c� I ' 4 HI -TOP SEATING I �I DN EXIT 2 PATH OF TRAVEL ` FROM TABLE TO B.O. STAIRS IS 116-1 < 250' 1/ BAR 103 (1/200) 162 SF 11 OCC WIN DINING 102 (1/15) 1101 SF 1 74 OCC AL SHELVING FOR -_ r?!ITTLES BAR 103 METAL Si FO 24"X36" E LIQUORS TTLES CABINET -- co2 PATIO 106 (1/15) 222 SF 115 OCC 8 HI -TOP 30" X 96" El `--`-- ` --"--" `--- 7' i di ' CA- LJ LJ LJ LJ LJLiIiiiT 0 o I_ FEC I sTo E I E IW H I BENCH STAIR TO HAVE 30" X 96" EXIT S 4 HI -TOP 4 HI -TOP ♦♦ TOP R IB 1023.9 E30" X 60" 1 30" X 60" �H NCH EXIT PATIO 2 106 h PATH TO PREP EXIT 2 TABLE 0 A ' m X / m A m PREP PREP / M TABLE TABLE / DINING DN I 102 I 3 _ y � 4 TOP 4 TOP Ir�< E30" X 60" 30" X 60" DN q&TEXPO/ I E I� _ P - I PICK UF I8 TOP h � LINE 3` �O 261 1 /2" WITH � X DN BENCH , 4 TOP 4 TOP FROM 1OF OF ' 1 30" X 60" 30" X 60" ST IRS T IT FS n C1R 2 ,. IO N N EXIT' 21 TO I Z (8'-2")..,. `— EGRESS DOb w gWOW � WIC TO T POINT IS '-3" 8 TOP 8 TOP BENCHE BENCHE 30" X 96" 30" X 96" f >ERVIC r1 24" X 4"" V CABINET / STORAGE I ...... I � I fn 2 m D 'A 1 TO -GO SHELVING/ RACKING ELEVATOR TO ACT AS ACCESSIBLE MEANS OF EGRESS PER IBC 1009 EXITING & OCCUPANY PLAN - UPPER LEVEL SCALE :1 /8" = 1'- 0" ELEC PANEL FEC w z w Q C� KITCHEN 104 (1/200) 822 SF 1 5 OCC EXIT 1 PATH OF TRAVEL FROM WIC TO EGRESS DOOR IS 119'-7" < 250' SERVICE 101 (1/200) 64 SF OCC F ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. ORE TZ STATE OF W SHI TON JOH N NY MO'S PIZZERIA 558 MAIN STREET EDMONDS, WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 CORR RESPONSE #1 10.31.2022 CODE ANALYSIS OCCUPANCY & EXITING DATE SCALE DRAWN ETK & FO JOB # 22-037 copyrigl ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or In part without the written authorization of Urbal Architecture, PLLC. RESUB Nov 01 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A0010 r-2- EXITING & OCCUPANY PLAN - LOWER LEVEL i 10 SCALE :1 /8" = 1'- 0"