Loading...
REVIEWED BLD2022-0764+Mechanical Form+9.21.2022_3.39.41_PM+3122369MECHANICAL COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl Administered by: ©2022 NEEA, All rights reserved Project Title Molly Moon's Homemade Ice Cream - 2018 WSEC For Building Department Use: Date: Aug 31, 2022 558MAIN ST Project &Applicant Information Project Address Suite 4 EDMONDS, WA 98020 .............................................. REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT;; .RECEIVED Oct 03 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-0764 Applicant Name Tosh Drake Applicant Phone PP 206-617-0741 Applicant Email tosh.drake@migration.eco For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Dining, Restaurant/Bar Building Cond. Floor Area 790 General Project Types Tenant Spaces — First Build Out New Building or Addition Mechanical Scope Alteration Mechanical Scope Single Zone Systems & Equipment Project Cond. Floor Area 790 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Mechanical Project Description Install 2 ductless air handlers as part of a VRF system Economizer DOAS Ventilation Higher Equipment Equipment Efficiency Mechanical Compliance Project Type Mechanical Scope Exception(s) � Provided? EfficiencyOptionA lied? PP Compliance Applied. Verification Scope and Method Tenant Spaces —First Build Single Zone Systems & Yes No NA COMPLIES Out Equipment Additional Efficiency Credits Included (AEC) Does building include occupancy classifications requiring No Does project include DOAS equipment? No DOAS? Based on project scope do TSPR requirements apply? No Do all systems comply with Appendix D standard reference design or qualify for an exception to No TSPR? Scope & Space Conditioning TENANT SPACES — FIRST BUILD OUT - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category - Heat pump, unitary, thru-wall, SDHV Air Systems Summary Information System/Equip ID Quantity Supply Airflow Ventilation Standard Ventilation CFM Ventilation Paired with DOAS Ventilation energy recovery Energy Recovery of Items Control (Total if Multiple Items) Air Source Efficiency (%) AH-7 Variable air volume IMC Natural Ventilation AH-6 Variable air volume IMC Natural Ventilation Air Systems & Equipment - Cooling System/ Cooling System/Equip Type Specific Type Cooling Capacity AEC Efficiency Econo Exception Combined Efficiency Proposed Cooling CE Proposed Part PL Efficiency Compliance Equip ID per item (Btu/h) Multiplier Multiplier (FL & PL) Multiplier (AEC & Econo) Efficiency Units Load Efficiency Units Verification AH-71 Heat pump, air cooled Split system 1 24,000 1 1 1.64 1.64 23.0 SEER IEER COMPLIES AH-61 Heat pump, air cooled Split system 1 24,000 1 1 1.64 1.64 23.0 SEER IEER COMPLIES Air Systems & Equipment - Heating System Heating System/Equip Type Specific Type Heat Pump Heating Capacity (Btu/h) Cooling Capacity (Btu/h) AEC Efficiency Proposed Heat Pump HPH Proposed Low OSA LTH Efficiency Compliance /Equip ID Multiplier Heating Efficiency Units Temp Efficiency Units Verification AH-61 Heat pump, air cooled, heating Split system 1 27,000 24,000 1 8.2 HSPF COP COMPLIES AH-71 Heat pump, air cooled, heating Split system 1 27,000 24,000 1 8.2 HSPF COP COMPLIES Air systems & Equipment uetaus System/Equip ID Area(s) Served Location In Project Documents - Plan/Detail # AH-7 Tenant space All System/Equip ID for a single or multiple items?: Single item Heating Section/Auxiliary Heating Type: Electric resistance (or None) Economizer Compliance Method: Applying air -side economizer exception Air -side economizer exception applied: Exp3(1) - HE single zone system, Climate Zone 4C WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(2) - Unitary and Applied Heat Pumps Proposed Low OSA Temp Efficiency: LTH Units: COP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(2) - Unitary and Applied Heat Pumps AH-6 Tenant space F All System/Equip ID for a single or multiple items?: Single item Heating Section/Auxiliary Heating Type: Electric resistance (or None) Economizer Compliance Method: Applying air -side economizer exception Air -side economizer exception applied: Exp3(1) - HE single zone system, Climate Zone 4C WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(2) - Unitary and Applied Heat Pumps Proposed Low OSA Temp Efficiency: LTH Units: COP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(2) - Unitary and Applied Heat Pumps