Loading...
REVIEWED RESUB 1 BLD2022-1217+Interior_Lighting_Summary+11.1.2022_8.38.33_AM+319604510/27/22, 1:53 PM https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llNONwZF9pbmlOaWFsX3RIbmFudCZOZnY9bHRnX... LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl C C' ' Q Administered by: C2022 NEEA, All rights reserved Project & Applicant Information Project Title Johnny Mo's Edmonds - 2018 WSEC For Building Department Use: L.0 I Date: Oct 27, 2022 REVIEWED Nov 01 2022 BY CITY OFEDMONDS BLD2022-1217 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Project Address 558 Main Street 200 Edmonds, WA 98020 Applicant Name Erin Kelly Applicant Phone 206-676-5633 Applicant Email Brink@mbalarchitecture.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Dining, Restaurant/Bar I Building Cond. Floor Area 2,356 General Project Types Tenant Spaces — First Build Out New Building or Addition Lighting Scope g g P Interior Lighting Alteration Lighting Scope Project Cond. Floor Area 2,356 Floors Above Grade 2 Compliance Method Compliance Method 1 -General Lighting Project Description Lighting Compliance Scope Project a j TyP Interior / Exterior Luminaire Replacement Scope P P Compliance Method P LPA Calculation Compliance Verification P (mterior Includes both interior & parking) Adjustment and Method Tenant Spaces —First Build Out Interior Lighting Space by space No Calculation Adjustments selected COMPLIES Additional Efficiency Options Included Project go Johnny Mo's Edmonds - 2018 WSEC Date Oct 27, 2022 Lighting Power Calculatio TENANT SPACES — FIRST BUILD OUT - INTERIOR LIGHTING Compliance Verification I COMPLIES Compliance Method Space by space LPA Calculation Adjustment I none Interior Lighting Power Allowance- Space by Space General Space Type Specific Space Type Ceiling Height (Ft) Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Dining area General 65 0.43 28 Dining area Bar/lounge/leisure dining 162 0.86 139 Dining area Family dining 1,100 0.60 660 Food preparation 822 1.09 896 Proposed Total LPD 1366 Totals 1 1,723 1 1,366 COMPLIES Proposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WPF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Direct / indirect pendant Fl 6 50 300 Direct / indirect pendant P3 3 20 60 Direct / indirect pendant P3 4 20 80 Direct / indirect pendant Pi I I 40 440 Direct/ indirect pendant CI 4 1 15 60 Direct / indirect pendant P2 3 7 21 Direct / indirect pendant Cl 3 15 45 Horizontal surface -mount Sl 6 60 360 Proposed Total LPD 1366 Project Title Johnny Mo's Edmonds - 2018 WSEC Date Oct 27, 2022 Proposed Fixtures Details III TENANT SPACES — FIRST BUILD OUT - INTERIOR LIGHTIN Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Direct / indirect pendant F 1 104 LED New Fixture Description: LED Ready Troffer PLT-90192 Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: None required Direct / indirect pendant P3 101 LED New Fixture Description: 8" Mini Pendant Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: None required Direct / indirect pendant P3 4 LED New Fixture Description: 8" Mini Pendant Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: None required https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3l I NONwZF9pbmlOaW FsX3RIbmFudCZOZnY9bHRnX3Njb3BIX25ld 19pbnRl ... 1 /2 10/27/22, 1:53 PM https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llNONwZF9pbmlOaWFsX3RIbmFudCZOZnY9bHRnX... Direct/ indirect pendant l Pi 1 101 1 LED I I New Fixture Description: Plumbing Pipe Cage Pendant Light Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: None required Direct/ indirect pendant Cl 1 103 LED New Fixture Description: Single Light S' Wide Outdoor Mini Pendant Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: None required Direct / indirect pendant P2 1 102 LED New Fixture Description: Church 3 Ann Pendant Light Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: None required Direct / indirect pendant Cl 1 101 LED New Fixture Description: Single Light S' Wide Outdoor Mini Pendant Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: None required Horizontal surface -mount Sl 1 102 LED New R E %SJ14 Fixture Description: Emory Outdoor Gooseneck Wall Sconce Black Are these fixtures located within a daylight zone?: Do these fixtures require specific application lighting controls?: None required CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3l l NONwZF9pbmlOaW FsX3RIbmFudCZOZnY9bHRnX3Njb3BIX25ld 19pbnRl ... 2/2