REVIEWED RESUB 1 BLD2022-1217+Interior_Lighting_Summary+11.1.2022_8.38.33_AM+319604510/27/22, 1:53 PM https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llNONwZF9pbmlOaWFsX3RIbmFudCZOZnY9bHRnX...
LIGHTING COMPLIANCE SUMMARY
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all Rl C C' ' Q Administered by: C2022 NEEA, All rights reserved
Project & Applicant
Information
Project Title
Johnny Mo's Edmonds - 2018 WSEC
For Building Department Use: L.0 I Date: Oct 27, 2022
REVIEWED Nov 01 2022
BY CITY OFEDMONDS BLD2022-1217
CITY OF EDMONDS DEVELOPMENT SERVICES
DEPARTMENT
Project Address
558 Main Street
200
Edmonds, WA 98020
Applicant Name
Erin Kelly
Applicant Phone
206-676-5633
Applicant Email
Brink@mbalarchitecture.com
For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com
General Occupancy
All Commercial
General Building Use Type
Dining, Restaurant/Bar
I Building Cond. Floor Area
2,356
General Project Types
Tenant Spaces — First Build Out
New Building or
Addition
Lighting Scope
g g P
Interior Lighting
Alteration
Lighting Scope
Project Cond. Floor Area
2,356
Floors Above Grade
2
Compliance Method
Compliance Method 1 -General
Lighting Project Description
Lighting Compliance Scope
Project a
j TyP
Interior / Exterior
Luminaire Replacement Scope
P P
Compliance Method
P
LPA Calculation
Compliance Verification
P
(mterior Includes both interior & parking)
Adjustment
and Method
Tenant Spaces —First Build Out
Interior Lighting
Space by space
No Calculation Adjustments selected
COMPLIES
Additional Efficiency
Options Included
Project go
Johnny Mo's Edmonds - 2018 WSEC Date Oct 27, 2022
Lighting Power Calculatio TENANT SPACES — FIRST BUILD OUT - INTERIOR LIGHTING Compliance Verification I COMPLIES
Compliance Method Space by space LPA Calculation Adjustment I none
Interior Lighting Power Allowance- Space by Space
General Space Type
Specific Space Type
Ceiling
Height (Ft)
Gross Interior Area (SF)
LPA (Watts/SF)
Total Watts Allowed
(SF x LPA x 1)
Total Proposed Watts
(LPD + Display LPD)
Compliance Status
Dining area
General
65
0.43
28
Dining area
Bar/lounge/leisure dining
162
0.86
139
Dining area
Family dining
1,100
0.60
660
Food preparation
822
1.09
896
Proposed Total LPD
1366
Totals
1 1,723
1 1,366
COMPLIES
Proposed Lighting Power Density
Fixture Type
Fixture ID
Quantity of
Fixtures (#F)
Watts or
Wattage Limit
per Fixture
(WPF)
Total Linear
Feet (LF)
Watts per Linear
Foot (WpLF)
Total Watts
Proposed
(#F x WpF) or
(LF x WpLF)
Individual Fixtures
Direct / indirect pendant
Fl
6
50
300
Direct / indirect pendant
P3
3
20
60
Direct / indirect pendant
P3
4
20
80
Direct / indirect pendant
Pi
I I
40
440
Direct/ indirect pendant
CI
4
1 15
60
Direct / indirect pendant
P2
3
7
21
Direct / indirect pendant
Cl
3
15
45
Horizontal surface -mount
Sl
6
60
360
Proposed Total LPD
1366
Project Title
Johnny Mo's Edmonds - 2018 WSEC
Date
Oct 27, 2022
Proposed Fixtures Details
III TENANT SPACES — FIRST BUILD OUT - INTERIOR LIGHTIN
Fixture Type/Application
Fixture ID
Location in Documents Lamp Type
New or
Existing -to -Remain
Individual Fixtures
Direct / indirect pendant
F 1
104 LED
New
Fixture Description: LED Ready Troffer PLT-90192
Are these fixtures located within a daylight zone?:
Do these fixtures require specific application lighting controls?: None required
Direct / indirect pendant
P3 101 LED
New
Fixture Description: 8" Mini Pendant
Are these fixtures located within a daylight zone?:
Do these fixtures require specific application lighting controls?: None required
Direct / indirect pendant
P3 4 LED
New
Fixture Description: 8" Mini Pendant
Are these fixtures located within a daylight zone?:
Do these fixtures require specific application lighting controls?: None required
https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3l I NONwZF9pbmlOaW FsX3RIbmFudCZOZnY9bHRnX3Njb3BIX25ld 19pbnRl ... 1 /2
10/27/22, 1:53 PM https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3llNONwZF9pbmlOaWFsX3RIbmFudCZOZnY9bHRnX...
Direct/ indirect pendant l Pi 1 101 1 LED I I New
Fixture Description: Plumbing Pipe Cage Pendant Light
Are these
fixtures located within a
daylight zone?:
Do these fixtures require specific application lighting controls?: None required
Direct/ indirect pendant
Cl 1 103
LED
New
Fixture Description: Single Light S' Wide Outdoor Mini Pendant
Are these
fixtures located within a
daylight zone?:
Do these fixtures require specific application lighting controls?: None required
Direct / indirect pendant
P2 1 102
LED
New
Fixture Description: Church 3 Ann Pendant Light
Are these
fixtures located within a
daylight zone?:
Do these fixtures require specific application lighting controls?: None required
Direct / indirect pendant
Cl 1 101
LED
New
Fixture Description: Single Light S' Wide Outdoor Mini Pendant
Are these
fixtures located within a
daylight zone?:
Do these fixtures require specific application lighting controls?: None required
Horizontal surface -mount
Sl 1 102
LED
New
R
E %SJ14
Fixture Description: Emory Outdoor Gooseneck Wall Sconce Black
Are these
fixtures located within a
daylight zone?:
Do these fixtures require specific application lighting controls?: None required
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3BOPWxOZ19zY29wZV9uZXdfaW50ZXJpb3l l NONwZF9pbmlOaW FsX3RIbmFudCZOZnY9bHRnX3Njb3BIX25ld 19pbnRl ... 2/2