Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SEE REV1 APPROVED BLD ENG FIR PLN_RESUB1 BLD2022-1217+Architectural_Plan
JOHNNY MO'S PIZZERIA EDMONDS. WA SEPT. 13, 2022 - PERMIT SET ed States Kahlo's� C Postal Service North Sound Center Edmonds Eanona. st © r7a ss'/ Municipal Court t %la/n / o Rick Sieves' Europe Corpus Christi Chapel O © 0 Run for Good Racing Company ���� hgc Salt and Iron Charcoal-1,-SSS o ®Edmonds "I si m ig c Summer Market .c `� ® O'Malley Brothers INC9 WORKHORSE Chamerelle Rusty Pelican Cafe eeae3stss Edmonds yo �`� y} Historical Museum / Studio ProminenceQ z Edmonds Parks, uece st ©Coastal Community Bank Recreation & Cultural... Edmonds Ferry Terminal ® Main St © Main St 9 t QEdmonds Landing B Booth s MARKET Edmonds SIT Edmonds Arts Festival Assisted Living QBeresf PLLC Lawyers yers < seafood 55 Q y 9Red Twig Cafe and Bakery p v Main Street Kids OPreschool& Child Care... ® Dayton St ® © Dayion St Dayton St IS Dayton St 13 2 WesterlyQ - Salish Sea Brewing _ > Co & Restaurant Art Works Edmonds w w Cafe Louvree p anarinCanarino Gelato Caffe m v .55 Augustus Bukowski-Cardinal... Maple st Maple St /w A Maple sl VICINITY MAP MAIN STREET GENERAL NOTES 1. ALL WORK IS TO BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE SEATTLE BUILDING, MECHANICAL, ELECTRICAL AND PLUMBING CODES, AND ALL APPLICABLE CODES AND ORDINANCES. IN THE EVENT OF CONFLICT BETWEEN PERTINENT CODES AND REGULATIONS AND THE REQUIREMENTS OF THE REFERENCED STANDARDS OF THESE NOTES, THE PROVISIONS OF THE MORE STRINGENT SHALL GOVERN. 2. THE CONTRACTOR SHALL VERIFY ALL THE INFORMATION IN THE DRAWINGS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCY PRIOR TO ORDERING MATERIALS OR COMMENCING WITH WORK. THE CONTRACTOR SHALL VISIT THE SITE AND SHALL NOTIFY THE ARCHITECT IF THERE ARE ANY OBSERVED DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS. 3. THE CONTRACTOR SHALL PROVIDE ALL MATERIAL, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE THE WORK EXCEPT FOR THOSE ITEMS SHOWN AS N.I.C. (NOT IN CONTRACT). IF HIDDEN OR UNUSUAL "LANS M UST BE SITUATIONS ARE ENCOUNTERED DURING CONSTRUCTION WHICH 0!! ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & I N D U S T g tESZ' -� D 558 MAIN STREET i EAST BUILDING I WEST BUILDING AREA OF WORK i UNDER SEPARATE PERMIT 21353 SF i T ENTRY I O O O O O O O I ALLEY------------------------------------------------------------------------------------------- I SITE PLAN AO.00J SCALE .1 /16 11- 011 11-15-2022 PLAN REVIEW NOTES: APPROVED DEFERRED SUBMITALLS 1. FIRE SPRINKLER 2. FIRE ALARM 3. HOOD SUPPRESSION IF TYPE 1 HOOD. DFM BURT Approved DFM ChrL'sg�crt South County Fire Date: 11 /15/2022 Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. REVISIONS DATE PAGES CHANGES REV1 REV2 REVS REW REV5 COULD NOT HAVE BEEN FORSEEN PRIOR TO CONSTRUCTION, NOTIFY THE ARCHITECT BEFORE PROCCEEDING WITH THE WORK. 4. THE CONTRACTOR SHALL NOT ENCUMBER ANY PUBLIC OR PRIVATE PROPERTY OTHER THAN THE SITE WITHOUT ENCROACHMENT PERMITS OR WRITTEN PERMISSION FROM THE PROPERTY OWNERS. 5. THE CONTRACTOR SHALL PROVIDE FENCING, BARRICADES, WARNING SIGNS/SIGNALS OR OTHER PROTECTIVE MEASURES AS NEEDED TO PROVIDE FOR THE PUBLIC'S SAFETY. 6. THE CONTRACTOR SHALL SCHEDULE AND COORDINATE ALL INSPECTIONS AND AT THE END OF THE WORK PROVIDE THE OWNER WITH ALL THE ORIGINAL SIGNED DOCUMENTS FROM ANY INSPECTING ENTITY. 7. TYPICAL DETAILS AND NOTES SHALL APPLY UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE. DETAILS NOT FULLY SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS SHOWN FOR SIMILAR CONDITIONS. DIMENSIONS TAKE PRECEDENCE OVER SCALE SHOWN ON DRAWINGS. SCALING DRAWINGS TO DETERMINE DIMENSIONS IS NOT VALID. 8. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DESIGN AND PROVIDE SHORING, BRACING, FORMWORK, ETC., AS REQUIRED TO PROTECT LIFE AND PROPERTY. 9. JOB COPIES OF THE BUILDING & PERMITS SHALL BE ON -SITE DURING INSPECTIONS. 10. MECHANICAL, ELECTRICAL, AND TELEPHONE/DATA WORK SHALL BE PERFORMED AS DESIGN/BUILD SUB -CONTRACTS, EACH SUB -CONTRACTOR SHALL SECURE ALL PERMITS AS REQUIRED FOR THEIR SCOPE OF WORK. 11. PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK, THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE CONTRACT DOCUMENTS, OWNER -PROVIDED INFORMATION AND SITE CONDITIONS, INCLUDING TAKING FIELD MEASUREMENTS. 12. DIMENSIONS OF EXISTING CONDITIONS ARE FROM DRAWINGS BY OTHERS. ARCHITECT BEARS NO RESPONSIBILITY FOR ACCURACY OF W THE EXISTING AS -BUILT DRAWINGS. DIMENSIONS ARE TO FACE OF > INTERIOR FINISH, EXISTING WALL, OR CENTERLINE OF NEW INTERIOR Q WALL, UNLESS OTHERWISE NOTED. NOTIFY ARCHITECT OF ANY = DISCREPANCIES FOUND. DO NOT SCALE DRAWINGS. 13. REPETITIVE ELEMENTS: TYPICAL WALL SECTIONS, FINISHES AND 1110 DETAILS ARE NOT INDICATED EVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS AND SECTIONS. REFER TO DETAILED DRAWINGS. CONTRACTOR TO PROVIDE AS IF DRAWN IN FULL EVERYWHERE 14. THE CONTRACTOR SHALL CONSULT THE PLANS OF ALL TRADES FOR OPENINGS THROUGH SLABS, WALLS, CEILINGS AND ROOFS FOR DUCTS, PIPES, CONDUIT, CABINETS AND EQUIPMENT, AND SHALL VERIFY THE SIZES AND LOCATIONS WITH SUBCONTRACTORS. 15. ABBREVIATIONS: THROUGHOUT THE PLANS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE ARCHITECT WILL DEFINE THE INTENT OF ANY ABBREVIATION IN QUESTION. ABBREVIATIONS OR PARTIAL CODE SECTIONS NOTED ON THIS PLAN AND PLAN REVIEW LIST ARE INTENDED TO INDICATE THE NATURE OF THE PLANS OR GIVE ADDITIONAL INFORMATION. THE FULL TEXT OF THE CODE ALWAYS APPLIES. ENGINEERING DIVISION APPROVED AS NOTED 11 /14/2022 ***ALL MATERIALS, EQUIPMENTS, CONSTRUCTION VEHICLES, ETC TO BE LOCATED ON PRIVATE PROPERTY. NO APPROVAL FOR USE OF THE CITY RIGHT-OF-WAY.*** DEFERRED SUBMITTALS MECHANICAL PLUMBING ELECTRICAL FIRE SPRINKLER (MODIFICATIONS IF NEEDED) FIRE ALARM ADDRESS 550 MAIN STREET, SEATTLE, WA 98020 PROPERTY OWNER: MIKE MCMURRAY, SEATTLE-SNOHOMISH MILL COMPANY, INC 533 5TH AVE S EDMONDS, WA 98020 GECK08080@GMAIL.COM (425) 263-2474 PROPERTY TAX ACCOUNT NUMBER 004342-120-015-00 AND 004342-120-017-00 (BEING COMBINED UNDER SEPARATE APPLICATION SITE AREA LOT SIZE 19,789 GSF LEGAL DESCRIPTION LOTS 15 AND 16, BLOCK 120, CITY OF EDMONDS ADDITION, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 2 OF PLATS, PAGE 39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. AND; LOTS 17, 18, 19 AND 20, BLOCK 120, CITY OF EDMONDS ADDITION, ACCORDING TO THE PLATE THEREOF, RECORDED ION VOLUME 2 OF PLATS, PAGE 39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. ZONING BD1 USE - OCCUPANCY EXISTING USE OF SPACE: "A3" EVENT SPACE PROPOSED USE OF SPACE- OFFICE - "A2" RESTAURANT CONSTRUCTION TYPE TYPE VB SPRINKLERED (UNDER PREVIOUS PERMIT) F.111 V we] IW1T[61VEl4 RESTAURANT- 2,356 SF EXISTING DECKS/PATIOS: WEST- 500 SF NORTH- 256 SF PROJECT DESCRIPTION FIRST TIME BUILD OUT OF NEW TENANT SPACE. SPLIT-LEVEL WITH EXISTING ELEVATOR SERVICE. PROPOSED RESTAURANT WITH KITCHEN AREA, BAR AREA, SERVICE AREA, TWO EXISTING PATIO AREAS FOR SEATING/DRINKING. BATHROOM FOR PATRONS WILL BE ON LOWER LEVEL AND COMPLETED AS PART OF SHELL & CORE PERMIT( BLD2019-0529 & 0530) GOVERNING CODES 2018 INTERNATIONAL BUILDING CODE (IBC) WITH STATE AMENDMENTS 2018 INTERNATIONAL EXISTING BUILDING CODE WITH STATE AMENDMENTS 2018 INTERNATIONAL MECHANICAL CODE (INCLUDING INTERNATIONAL FUEL GAS CODE) WITH STATE AMENDMENTS 2018 INTERNATIONAL FIRE CODE WITH STATE AMENDMENTS 2018 UNIFORM PLUMBING CODE (IBC) WITH STATE AMENDMENTS 2018 WASHINGTON STATE ENERGY CODE (WAC 51-11) 2018 INTERNATIONAL PROPERTY MAINTENANCE CODE EDMONDS COMMUNITY DEVELOPMENT CODE 2014 NATIONAL ELECTRICAL CODE CONTACTS BUILDING OWNER MIKE MCMURRAY, SEATTLE-SNOHOMISH MILL COMPANY, INC 533 5TH AVE S EDMONDS, WA 98020 GECK08080@GMAIL.COM (425) 263-2474 LESSEE: JOHNNY MO'S PIZZERIA JOHN GENNA 3227 FUHRMAN ACE E, #100 SEATTLE WA, PHONE: 206-822-6272 EMAIL: JOHNNY@JOHNNYMOS.COM ARCHITECT: URBAL ARCHITECTURE 1938 FAIRVIEW AVE E, SUITE 100 SEATTLE, WA 98102 P 206-676-5645 CONTACT: CHAD LORENTZ CHADL@URBALARCHITECTURE.COM DRAWING INDEX ARCHITECTURAL A0.00 COVER SHEET A0.01 ABBREVIATIONS & LEGEND A0.10 CODE ANALYSIS -OCCUPANCY & EXITING I A2.00 FLOOR PLAN- UPPER FLOOR A2.01 FLOOR PLAN- LOWER FLOOR (FOR REFERENCE ONLY) A3.00 REFLECTING CEILING PLAN A4.00 ROOF PLAN A5.00 EXTERIOR ELEVATIONS A6.00 BUILDING SECTIONS A7.00 INTERIOR ELEVATIONS A7.01 INTERIOR ELEVATIONS A7.02 KITCHEN ELEVATIONS A8.00 RESTROOM ELEVATION A8.01 RESTROOM ELEVATION A9.00 WALL DETAILS A9.01 CASEWORK DETAILS A10.00 FINISH PLAN/SCHEDULE KITCHEN K1 EQUIPMENT PLAN K2 EQUIPMENT SCHEDULE K3 ELECTRICAL ROUGH IN PLAN K4 MECHANICAL ROUGH IN PLAN Sep�#e permits reW�T BACKING PLAN Plumbing Mechanical Type 1 hood Fire Suppression Separate approvals from Snohomish County Health District required. CONTRACTOR WESTERN VENTURES CONSTRUCTION RYAN CARLISLE PO BOX 298 MOUNTLAKE TERRACE, WA 98043 PHONE: 425-640-5050 EMAIL: INFO@WESTERNVENTU RES.COM LAty UT tamonas Building Department --------------------------------------------- Work TENANT IMPROVEMENT ----------------------------------------- r------------------------------------------------------- Address' 550 MAIN ST Owner JOHNNY MO'S PIZZA Approved Date Elrl.fi CAA-rfe r r Building Official 11 /14/2022 Permit Number; BLD2022-1217 CONSTRUCTION TYPE VB OCCUPANCY GROUP A-2 OCCUPANT LOAD 121 APPROVED BY PLANNING 4lAM� Oct 07 2022 ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. ORE "I Z STATE OF W SHI TON JOHNNY MO'S 558 MAIN STREET EDMONDS, WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 CORK RESPONSE #1 10.31.2022 COVER SHEET DATE SCALE DRAWN ETK & FO JOB # 22-037 )yrigl ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used In whole or in part without the written authorization of Urbal Architecture, PLLC. RESUB Nov 01 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GENERAL ABBREVIATIONS: SYMBOLS LEGEND URBAL GENERAL ABBREVIATIONS ANCHOR BOLT AB ABV ABOVE ACOUS ACOUSTICAL ACT ACOUSTICAL CEILING TILE AD AREA DRAIN ADDL ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR AG ALUMINUM & GLASS ALC ALUMINUM CLAD ALT ALTERNATE ALUM ALUMINUM ALV ALUMINUM CLAD VINYL ALW ALUMINUM CLAD WOOD AN ANODIZED APPROX APPROXIMATE APT APARTMENT ARCH ARCHITECTURAL AS ALUMINUM STOREFRONT AVG AVERAGE AWN AWNING B.O. BOTTOM OF BA BATH BC BOTTOM OF CURB BD BOARD BLW BELOW BITUM BITUMINOUS BLDG BUILDING BLKG BLOCKING BLW BELOW BM BEAM BSMT BASEMENT B/T BETWEEN BUR BUILT-UP ROOFING BYD BEYOND C CASEMENT C&G CURB AND GUTTER CAB CABINET CB CATCH BASIN CC CENTER TO CENTER CIP CAST IN PLACE CIRC CIRCULATION CL CENTERLINE CLG CEILING CLR CLEAR CLR FIN CLEAR FINISH CMU CONCRETE MASONRY UNIT CO CLEAN OUT COL COLUMN CONIC CONCRETE CONT CONTINUOUS CORR CORRIDOR CPT CARPET CT CERAMIC TILE CTB CERAMIC TILE BASE CTR CENTER CW COLD WATER CWG CLEAR WIRED GLASS CVG CLEAR VERTICAL GRAIN D DRYER DBL DOUBLE DE DELAYED EGRESS DEMO DEMOLITION DH DOUBLE HUNG DIA DIAMETER DR DOOR(S) DS DOWNSPOUT DW DISHWASHER DWG DRAWING EA EACH EB EXPANSION BOLT EF EACH FACE EL ELEVATION ELEC ELECTRICAL) ELEV ELEVATOR EMER EMERGENCY ENCL ENCLOSURE EP ELECTRICAL PANEL EQ EQUAL EQUIP EQUIPMENT ESCAL ESCALATOR ESMT EASEMENT EXH EXHAUST EXST EXISTING EXT EXTERIOR F FIXED FA FIRE ALARM FAF FACTORY APPLIED FINISH FAP FIRE ALARM CONTROL PANEL FAPB FIRE ALARM PULL BOX FB FLAT BAR FBG FIBERGLASS FC FIBER CEMENT FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FDN FOUNDATION FDR FRENCH DOORS FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FIN FINISH FL FLUSH FLR FLOOR F.O.C. FACE OF CONCRETE F.O.F. FACE OF FINISH F.O.M. FACE OF MASONRY F.O.S. FACE OF STUDS FPL FIREPLACE FIR FRAMING FRP FIBER REINFORCED PLASTIC FRT FIRE RETARDANT FRTW FIRE RETARDANT TREATED WOOD FT FOOT (OR FEET) FTG FOOTING FURR FURRING FUT FUTURE GA GAUGE GALV GALVANIZED GAR GARAGE GB GRAB BAR GC GENERAL CONTRACTOR GFRC GLASS FIBER REINFORCED CONCRETE GL GLASS GLB GLU-LAMINATED BEAM GLZ GLAZING GND GROUND GS GARAGE SECTIONAL DOOR GSF GROSS SQUARE FEET GWB GYPSUM WALL BOARD HB HOSE BIB HC HOLLOW CORE HCW HOLLOW CORE WOOD HD HEAD HDO HIGH DENSITY OVERLAY HDWD HARDWOOD HM HOLLOW METAL HORIZ HORIZONTAL HVAC HEATING VENTILATION AIR CONDITIONING HW HOT WATER HYDR HYDRAULIC IBC INTERNATIONAL BUILDING CODE ID INTERIOR DESIGN IIC IMPACT ISOLATION CLASS IN INCH(ES) INCL INCLUDING INS INSULATION INT INTERIOR JAN JANITOR KB KEY BOX / KNOX BOX KID KNOCK DOWN KIT KITCHEN KO KNOCK OUT KW KILOWATTS LAM LAMINATE LAV LAVATORY LB POUND LF LINEAR FEET LOC LOCATION LTG LIGHTING LOW-E LOW GLAZING LVR LOUVER MAINT MAINTENANCE MAS MASONRY MATL MATERIAL MAX MAXIMUM MB MACHINE BOLT MED MEDICINE MDF MEDIUM DENSITY FIBERBOARD MDO MEDIUM DENSITY OVERLAY MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEZZ MEZZANINE MFR MANUFACTURER MGR MANAGER MH MANHOLE MIN MINIMUM MIRR MIRROR MISC MISCELLANEOUS MK MARK MP METAL, PAINTED MTD MOUNTED MTL METAL MULL MULLION NIC NOT IN CONTRACT NOM NOMINAL NSF NET SQUARE FEET NTS NOT TO SCALE 0/ OVER CA OVERALL OC ON CENTER OD OVERFLOW ROOF DRAIN OFCI OWNER FURNISHED / CONTRACTOR INSTALLED OFF OFFICE OFOI OWNER FURNISHED / OWNER INSTALLED OPP OPPOSITE OVHD OVERHEAD OZ OUNCE PB PARTICLE BOARD PC PRECAST CONCRETE PCF POUNDS PER CUBIC FOOD PED PEDESTAL PERF PERFORATED PERP PERPENDICULAR PIC PICTURE (WINDOW) PIV POST INDICATOR VALV PL PROPERTY LINE PLAM PLASTIC LAMINATE PLAS PLASTER PLYWD PLYWOOD POLY POLYETHYLENE PREFAB PREFABRICATED PREFIN PREFINISHED PRKG PARKING PROP PROPERTY PRV PRESSURE REDUCING VALVE PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PNT POINT PT PRESSURE TREATED PTD PAINTED PVC POLYVINYL CHLORIDE PVMT PAVEMENT QTY QUANTITY R RISER RA RETURN AIR RAID RADIUS RC RESILIENT CHANNEL RCP REFLECTED CEILING PLAN RD ROOF DRAIN REFR REFRIGERATOR REINF REINFORCE REQD REQUIRE RESIL RESILIENT RL (INTERIOR) RELITE RSTRM RESTROOM RET RETAINING RO ROUGH OPENING ROW RIGHT OF WAY RWL RAIN WATER LEADER SA SUPPLY AIR SAF SAFETY LAMINATED SC SOLID CORE SCW SOLID CORE WOOD SECT SECTION SH SINGLE HUNG SHT SHEET SHTHG SHEATHING SIM SIMILAR SL SLIDING SLID SLIDING DOOR SOG SLAB ON GRADE SP STANDPIPE SPG SPANDREL GLAZING SPEC SPECIFICATION SSTL STAINLESS STEEL ST STAINED STA STATION STAG STAGGERED STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STM STEEL CHANNEL MEMBER STOR STORAGE STRUCT STRUCTURE (STRUCTURAL) SUSP SUSPENDED SV SHEET VINYL SYST SYSTEM T TEMPERED T&G TONGUE AND GROOVE T.O.B. TOP OF BEAM T.O.C. TOP OF CURB TD TRENCH DRAIN TEMP TEMPORARY T.O.F. TOP OF FOOTING T.O.F.F. TOP OF FINISH FLOOR THK THICK(NESS) T.O.J. TOP OF JOIST T.O. TOP OF T.O.C. TOP OF CONCRETE T.O.P. TOP OF PARAPET T.O.W. TOP OF WALL TOPO TOPOGRAPHIC TP TOP OF PAVEMENT TR TREAD TRANS TRANSLUCENT GLAZING TRTD TREATED TSTAT THERMOSTAT TV TELEVISION TYP TYPICAL UNEX UNEXCAVATED UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE UTIL UTILITIY (OR UTILITIES) VB VINYL BASE VCT VINYL COMPOSITION TILE VEH VEHICLE VENT VENTILATION VERT VERTICAL VEST VESTIBULE VG VERTICAL GRAIN V VINYL VIF VERIFY IN FIELD VNF VINYL NAIL -FLANGE VP VENEER PLASTER VTR VENT THROUGH ROOF W WASHING MACHINE WC WATER CLOSET WD WOOD W/D WASHER/DRYER WIG WOOD & GLASS WGL WIRE GLASS WH WATER HEATER W/0 WITHOUT W.P. WORKING POINT WP WATER PROOF WRB WATR-RESISTIVE BARRIER WDW I WINDOW(S) VIEW REFERENCES OBJECT REFERENCES BUILDING SECTION ROOM TAG DETAIL # ON SHEET ROOM NAME SIM ROOM NAME 1 101 ROOM # A10 150 SF SHEET # ROOM (NET) SQUARE FOOTAGE DETAIL CUT DOOR TAG DETAIL # ON SHEET SIM DOOR #; REFER TO 1 A10 DOOR SCHEDULE SHEET # ENLARGED PLAN OR DETAIL WINDOW TAG DETAIL # ON SHEET SIM �_ --- 1 WINDOW #; REFER TO it WINDOW SCHEDULE A101 > -Aav SHEET # BUILDING ELEVATION MATERIAL TAG 1 DETAIL #, TYP MATERIAL PER LEGEND 1 A101 1 PTA MTRL SHEET # PAINT COLOR PER LEGEND 1 INTERIOR ELEVATION WALL TAG 1 DETAIL #, TYP WALL TYPE *REFER TO SHEET A8.00 1 A101 1 FOR WALL ASSEMBLIES E SHEET # 1 HIDDEN ELEVATION ROOF/FLOOR/CEILING TAG DETAIL # ON SHEET X ROOF/ FLOOR/ CEILING IM 1 A101 TYPE SHEET # CODE COMPLIANT EXIT SIGN REVISION TAG WITH EMERGENCY LIGHTING EXIT 1 REVISION # DIRECTIONAL CODE COMPLIANT EXIT SIGN WITH EMERGENCY LIGHTING FEC CODE COMPLIANT FIRE EXTINGUISHER EXIT EXIT LOAD xx \Lx_Xxj EXIT CAPACITY 0.3" PER OCCUPANT FOR STAIRS 0.2" PER OCCUPANT FOR ALL OTHER COMPONENTS EXISTING WALLS & PARTITIONS (TO REMAIN) NEW PARTITION (TO MATCH HEIGHT OF EXISTING PARTITIONS) ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. ORE TZ STATE OF W SHI TON RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MO'S PIZZERIA 550 MAIN STREET EDMONDS,. WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 ABBREVS. LEGEND DATE SCALE DRAWN ETK & FO JOB # 22-037 ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used In whole or in part without the written authorization of Urbal Architecture, PLLC. A0001 OCCUPANCY CALCULATION: AREA: 2,344 GSF EXISTING USE: BUSINESS "A3" VACANT EVENT SPACE PROPOSED USE: BUSINESS "A2" RESTAURANT OCCUPANT LOAD FACTORS: 200 SF/ OCCUPANT BUSINESS 200 SF/OCCUPANT KITCHEN 15 SF/OCCUPANT ASSEMBLY NON -CONCENTRATED CONF. ROOM 300SF/OCCUPANT STORAGE • B OCCUPANCY: BAR 103: 162 SF = 1 OCCUPANTS SERVICE 101: 64 SF = 1 OCCUPANTS KITCHEN 104: 822 SF = 5 OCCUPANTS • A-2 OCCUPANCY DINING 102: 1101 SF: =74 OCCUPANTS PATIO 2: 222 SF: =15 OCCUPANTS PATIO 1: 455 SF =31 OCCUPANTS • S-1OCCUPANCY WIC 105: 104 SF = 1 OCCUPANTS TOTAL OCCUPANTS: 128 OCCUPANTS NUMBER OF EXITS PROVIDED FROM UPPER FLOOR: 2 EXIT NUMBER OF EGRESS STAIRS PROVIDED: 2 EGRESS LEGEND CLEAR PATH TRAVEL EXIT EXIT SIGNS E EMERGENCY ILLUMINATION FIXTURE PER IBC 1006.2 FEC FIRE EXTINGUISHER ADA SEATING CALCULATION DINING ZONE SEAT 5% OF SEAT (REQUIRED PROVIDED DINING 102 68 3.4 4 4 PATIO 106 28 1.4 2 2 PATIO 107 8 0.4 1 1 PLUMBING CALCULATION OCCUPANTS DINING 128 DIVIDE BY 2 64 DIVIDE BY 75 0.85 TOTAL 0.85 1 PER REQUIRED 1 PER PROVIDED PATIO 107 (1/15) 455 SF 131 OCC I 4 TOP 4 TOP 30" X 60" - 30" X 60" 4 TOP 4 TOP 30" X 60" 30" X 60" ATIO 1 107 4 TOP 30" X 60" 4TOP 30" X 60" LJ t EXIT PATH - E L DOWN TO GR c� I ' 4 HI -TOP SEATING I �I DN EXIT 2 PATH OF TRAVEL ` FROM TABLE TO B.O. STAIRS IS 116-1 < 250' 1/ BAR 103 (1/200) 162 SF 11 OCC WIN DINING 102 (1/15) 1101 SF 1 74 OCC AL SHELVING FOR -_ r?!ITTLES BAR 103 METAL Si FO 24"X36" E LIQUORS TTLES CABINET -- co2 PATIO 106 (1/15) 222 SF 115 OCC 8 HI -TOP 30" X 96" El `--`-- ` --"--" `--- 7' i di ' CA- LJ LJ LJ LJ LJLiIiiiT 0 o I_ FEC I sTo E I E IW H I BENCH STAIR TO HAVE 30" X 96" EXIT S 4 HI -TOP 4 HI -TOP ♦♦ TOP R IB 1023.9 E30" X 60" 1 30" X 60" �H NCH EXIT PATIO 2 106 h PATH TO PREP EXIT 2 TABLE 0 A ' m X / m A m PREP PREP / M TABLE TABLE / DINING DN I 102 I 3 _ y � 4 TOP 4 TOP Ir�< E30" X 60" 30" X 60" DN q&TEXPO/ I E I� _ P - I PICK UF I8 TOP h � LINE 3` �O 261 1 /2" WITH � X DN BENCH , 4 TOP 4 TOP FROM 1OF OF ' 1 30" X 60" 30" X 60" ST IRS T IT FS n C1R 2 ,. IO N N EXIT' 21 TO I Z (8'-2")..,. `— EGRESS DOb w gWOW � WIC TO T POINT IS '-3" 8 TOP 8 TOP BENCHE BENCHE 30" X 96" 30" X 96" f >ERVIC r1 24" X 4"" V CABINET / STORAGE I ...... I � I fn 2 m D 'A 1 TO -GO SHELVING/ RACKING ELEVATOR TO ACT AS ACCESSIBLE MEANS OF EGRESS PER IBC 1009 EXITING & OCCUPANY PLAN - UPPER LEVEL SCALE :1 /8" = 1'- 0" ELEC PANEL FEC w z w Q C� KITCHEN 104 (1/200) 822 SF 1 5 OCC EXIT 1 PATH OF TRAVEL FROM WIC TO EGRESS DOOR IS 119'-7" < 250' SERVICE 101 (1/200) 64 SF OCC F ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. ORE TZ STATE OF W SHI TON JOH N NY MO'S PIZZERIA 558 MAIN STREET EDMONDS, WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 CORR RESPONSE #1 10.31.2022 CODE ANALYSIS OCCUPANCY & EXITING DATE SCALE DRAWN ETK & FO JOB # 22-037 copyrigl ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or In part without the written authorization of Urbal Architecture, PLLC. RESUB Nov 01 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A0010 r-2- EXITING & OCCUPANY PLAN - LOWER LEVEL i 10 SCALE :1 /8" = 1'- 0" REMODELING KEY NOTES: 1. PARTITION HEIGHTS PER PLAN. 2. FURNITURE TO BE PROVIDED BY OWNER. 3. REUSE EXISTING EXIT SIGNS IF POSSIBLE, OR INSTALL NEW PER CODE. 4. SEE DETAILS FOR WALL FINISHES, MILLWORK, COUNTERTOP, LIGHTING FIXTURES, FLOORING, CABINET HARDWARE, AND APPLIANCES. 5. WINDOW FRAMES TO BE PAINTED PER INTERIOR. 6. PROVIDE ACOUSTICAL BATT INSULATION IN EXISTING WALLS IF NOT ALREADY PRESENT. 7. ANY SHELVING SHOWN IN CABINETS NEEDS TO BE ADJUSTABLE. ' 1 FLOOR PLAN - UPPER LEVEL A2.01 J SCALE :1 /4" — 1' - 0" L/x I %J 11 1 V V 3 TWO-SIDED 5.0o ELEVATOR SERVICE TO ALL LEVELS ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. ORE TZ STATE OF W SHI TON JOH N NY MO'S PIZZERIA 558 MAIN STREET EDMONDS, WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 CORK RESPONSE #1 10.31.2022 FLOOR PLAN - UPPER LEVEL DATE SCALE DRAWN ETK & FO JOB # 22-037 .yright Q2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. RESUB Nov 01 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A2■ FLOOR PLAN - LOWER LEVEL A2.00 J SCALE :1 /4" = 1' - 0" ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT N LORE TZ STATL 4 W SHI TON RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MOI PIZZERIA 550 MAIN STREET EDMONDS, WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 FLOOR PLAN - LOWER LEVEL (FOR REFERENCE) DATE SCALE _ DRAWN ETK & FO JOB # 22-037 )yrigl- ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document, All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. A2001 RCP NOTES: 1. LIGHTING PLAN TO MEET LOCAL ENERGY CODE. 2. ALL DINING ROOM LIGHTS TO BE CONTROLLED BY DIMMERS. PROVIDE UP TO 4 ZONES FOR DIMMING IN DINING. ALL LED TO BE DIMMABLE. KITCHEN LIGHTS TO BE DIMMABLE. 3. ALTERNATES TO BE APPROVED BY OWNER. 4. SHATTER PROOF BULBS IN KITCHEN AND BAR. 5. SCHEDULE WALK- THROUGH OF ALL LIGHTING LOCATIONS WITH OWNER PRIOR TO ROUGH -IN. 6. SEE ELEVATIONS FOR LIGHT FIXTURE MOUNTING HEIGHT. 7. ALL ELECTRONIC DEVICES TO BE INSTALLED IN WALL. 8. EMERGENCY LIGHTING LOCATION TO BE VERIFIED WITH FIRE MARSHALL AT WALK THRU. 9. COORDINATE WITH OWNER AND ARCHITECT ON ELECTRICAL LIGHT SWITCHING STRATEGY. E C1 C1 103 C1 C1 I P3 UP3P3 �P3 E1 S1 I ATIO 1 I 107 C -- P1 1 REFLECTING CEILING LEGEND - E1 I EXIT EXIT SIGNS I EMERGENCY ILLUMINATION FIXTURE v v PER IBC 1006.2 N E1 WALL MOUNTED TV PROVIDE WALL MOUNTING BACKING LIGHT FIXTURE LEGEND P1- PENDANT LIGHT FIXTURE P2- PENDANT LIGHT FIXTURE P4- PENDANT LIGHT FIXTURE C1h F1 S1- SCONCE GOOSENECK LIGHT FIXTURE —0--o— E1- STRING LIGHT FIXTURE W S1 DINING 0 E$2 -T 7- 0 EXIT IN EXISTING GLULAM BEAMS CEILING TYP. II I I I I I I I I I I SERVICE OO P3- PENDANT LIGHT FIXTURE F1- FLUORESCENT 2X4 LIGHT FIXTURE I I 51 P2 C1 DN 1 55" S1 © LIGHTING CONTROL PER OWNER LIGHTING SCHEDULE SYMBOL DESCRIPTION MANUF. MODEL # DIMMABLE FDIC REMARKS HEIGHT A.F.F/ SPACING P1 PENDANT EDISON LIGHT GLOBES PLUMBING PIPE CAGE PENDANT LIGHT SEE ZONE P2 PENDANT RAVENHILL STUDIO CHURCH 3 ARM PENDANT BLACK SEE ZONE P3 PENDANT DAINOLITE 8" MINI PENDANT SEE ZONE C1 PENDANT VOLUME LIGHTING SINGLE LIGHT 5" WIDE OUTDOOR MINI PENDANT SEE ZONE S1 SCONCE (Dinning Room) ALDER & ORE EMMY OUTDOOR GOOSENECK WALL SCONCE BLACK SEE ZONE F1 DIRECT 2X4 LED FIXTURE SEE ZONE E1 FESTOON LIGHTING CANARM STRING 15/E26-S14KT YES UC1 LED WITH DIFFUSER SEE ZONE EXITI I IN/A EXISTING T+G CAR DECKING, TYP. 1 REFLECTING CEILING PLAN- UPPER LEVEL SCALE :1/4" = 1'- 0" PATIO 2 106 E1 1 E1 E1 1 O K c II DN X DN WIG CEILING TREATMENT OVER KITCHEN + FOOD PREP AREA ALL EXISTING EXPOSED GLULAM BEAMS + CAR DECKING TO BE MATTE FINISH CLEAR SEALER (WASHABLE) . X - IS TING ✓AAA�QR PROPOSED HOOD PER KITCHEN CONSULTANT. m ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTE VARCHITEV A. ORE TZ STATE OF W SHI 'TON JOH N NY MO'S PIZZERIA 558 MAIN STREET EDMONDS, WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 CORR RESPONSE #1 10.31.2022 REFLECTING CEILING PLAN DATE SCALE DRAWN ETK & FO JOB # 22-037 copyrigl ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or In part without the written authorization of Urbal Architecture, PLLC. RESUB Nov 01 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A3000 \Alr—n—r Mr-1 r'1\A/ ROOF PLAN- EXISTING A4.00 % SCALE: 1/4" = 1' - 0" "IORTH PATIO/DECK BELOW 'IZZA OVEN EXHAUST FAN _) ROOF HATCH ACCESS V/ WALKABLE ROOF 1EMBRANE O/ ROOF ASSEMBLY PROPOSED AREA FOR RESTAURANT MECH EQUIPMENT ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. LjORE TZ STATE OF W SHI TON RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MO'S PIZZERIA 550 MAIN STREET EDMONDS,. WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 ROOF PLAN DATE SCALE DRAWN ETK & FO JOB # 22-037 )yrigl ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or In part without the written authorization of Urbal Architecture, PLLC. smber A4000 E.5 --------- - --------- ---- — -- — -- D.4 C.2 T\TTJ -------------- ---------------------------- -------------—-- — ---------------- A.8 n EL.+122.25' T.O. ELEVATOR TOWER EL.+120' -------------MAX. ALLOWABLE BUILDING HT. —-- — ----- ----- -- -- -- - - > _ +32' 4 1/2'(+119.48' - - - - - - - - - - - - - - T�TTOP-PD{TF +30'-5 1 /2"((+117.56') MF- - - - - - - - - - - - +30'-5 0 ;lU136ECK +20'-3" FIN FEF:F - - -� - - - - - � MONOSSON +23'-81/2" T.O. GUARDRAIL +20'-21/2" TERRACE FIN FLR 'FINISH GRADE I__I ��i LJ I__I T BLDG CORNER DE L- - - - - - - - -- EL. +90" AVERAGE GRADE OF BUILDING PAD +01-o" PROJECT EL. REFERENCE EXISTING EXTERIOR ELEVATION -EAST A5.00 SCALE :3/11 1' - 0" EL.+122.25' T.O. ELEVATOR TOWER EL.+120' MAX. ALLOWABLE BUILDING +3l 1/2" +117.E T.O. RO F 6l T.O. GU +16-3 L7{1QD1flZ�-FfI�F +15'-3 1.0. FIN F +8' LANDING FIN EXISTING EXTERIOR ELEVATION- WEST SCALE :3/16" = 1' - 0" L J I I I EXISTING EXTERIOR ELEVATION- SOUTH SCALE :3/16" - 1' - 0" ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. ORE TZ STATE OF W SHI TON -ant Inao RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MO'S PIZZERIA 550 MAIN STREET EDMONDS,. WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 EXTERIOR ELEVATION DATE SCALE DRAWN ETK & FO _ JOB # 22-037 copyrigl ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or In part without the written authorization of Urbal Architecture, PLLC. smber A5000 AREA OF WORK MA: +32 +30' T.O. F T EAST BUII FIN GRADE R1 III niNir, .qPr,TinNi- i nmir, PA-qT +32'-6" MAX. DUrU +32'-4 1 /2" T. +30'-5 11Z T.O. RO F l T. WEST SPACE + 4 4'-7 1 /4" T.O. SUBDECK +0'-2" EAST BUILDING T.O. SLAB +0'-011(+87.1' PROJECT EL. REF BUILDING SECTION- LOOKING NORTH SCALE: 3/1611 — 1' - 0" +18'-11" EVENT SPACE FIN FLR + 18'-10 1 /2" NORTH TERRACE T.O. PAVERS BUILDING SECTION- NORTH COVERED ENTRY SCALE :3/16" = 1' - 0" AREA OF WORK T.O. FIN SLAB NO PROPOSED WORK ON LOWER LEVEL. UNDER SEPARATE PERMIT. G TENANT 5 SLAB ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 lip 9776 REGISTERED ARCHITECT A. IORE TZ STATE OF W SHI TON consultant I(--n RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MO'S PIZZERIA 550 MAIN STREET EDMONDS, WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 BUILDING SECTION DATE SCALE DRAWN ETK & FO JOB # 22-037 copyrigi ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document, All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. sheet number A6000 1 A7.00 2 A7.00 LOWER PLAN- DINING ROOM/ BAR AREA NORTH SCALE :1/2" 1' - 0" LOWER PLAN- DINING ROOM/ SERVICE AREA SOUTH NOW Bin 9_101210a101[.yCl THIN BRICK FINISH BLACK 4" BLACK RUBBER BASE ` BLACK PAINTED GYPSUM FRP PANELS ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. QORE TZ STATE OF W SHI TON RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MO'S PIZZERIA 550 MAIN STREET EDMONDS,. WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 INTERIOR ELEVATIONS DATE SCALE DRAWN ETK & FO JOB # 22-037 ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or In part without the written authorization of Urinal Architecture, PLLC. A7000 SCALE :112" — 1' - 0" 1 A7.01 2 A7.01 LOWER PLAN - DINING ROOM/ SERVICE AREA EAST SCALE :1 /2" V - 0" LOWER PLAN - DINING ROOM/ BAR AREA WEST SCALE :1 /2" V - 0" T ULlIV I\ 1\V UULI\ U(lVL TYP. TYP. ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. LCRE TZ STATE OF W SHI TON tent Iran RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MO'S PIZZERIA 550 MAIN STREET EDMONDS,. WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 INTERIOR ELEVATIONS DATE SCALE DRAWN ETK & FO JOB # 22-037 copyrigl ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or In part without the written authorization of Urbal Architecture, PLLC. smber A7001 2'-0" 9'-2" 1'-10 3/4" 8'-8" 1'-7 1/4" KITCHEN ELEVATION -NORTH SCALE :1/2" 1' - 0" ± 33'-3" KITCHEN ELEVATION -EAST SCALE :1/2" 1' - 0" QTAIAII CQQ QTCCI n1 A—v — MAK-1 n 1`11 A—v — MAK-1 r KITCHEN ELEVATION- SOUTH SCALE .1/2" 1' - 0" KITCHEN ELEVATION EAST SERVICE LINE SCALE :1/2" 1' - 0" UL [x 1 —IN I— V I I -vi 20 9„ vv- 1 1-111.-1I am ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. QORE TZ STATE OF W SHI TON RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MO'S PIZZERIA 550 MAIN STREET EDMONDS,. WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 KITCHEN ELEVATIONS DATE SCALE DRAWN ETK & FO JOB # 22-037 )yrigl Q2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or In part without the written authorization of Urbal Architecture, PLLC. smber A7002 PROVIDE BLOCKING FOR TV MOUNTING BRACKETS PER MANUFACTURERS RECOMMENDATIONS HEIGHT OF WALL TREATMERNT PER INTERIOR ELEVATION 1X WALL TREATMENT FRP WALL COVER COLOR: BLACK FRP INTEGRAL BASE WHEN WALL COVERED WITH FRP EXISTING WALL AND FLOOR PER SHELL & CORE PERMIT EXISTING WINDOW 1X WOOD TRIM TOP RAIL 1X4 WOOD FACE TRIM GWB- TYPE "X" WALL TREATMENT PAINT -COLOR: TBD EXISTING GWB PER LANDLORD (SHELL CORE PERMIT) 4" RUBBER BASE TRIM EXISTING WALL AND FLOOR PER SHELL & CORE PERMIT EXISTING WALL TREATMENT- WINDOW SCALE. 1 "=1'-0" PROVIDE BLOCKING FOR TV MOUNTING BRACKETS PER MANUFACTURERS RECOMMENDATIONS HEIGHT OF WALL TREATMERNT PER INTERIOR ELEVATION 1X WALL TREATMENT TYPE: STAIN: 4" RUBBER BASE TRIM EXISTING WALL AND FLOOR PER SHELL & CORE PERMIT � OR 2X6 TOP PLATE INSIDE FLECTION TRACK PER WALL PE, CONNECT TO EXISTING AMING AS REQUIRED WOOD STUD PARTITION WALL PER PLAN/SCHEDULE- DETAIL: WALL TO CEILING CONNECTION SCALE: 1"=1'-0" WOOD BASE TRIM PER INTERIOR ELEVATIONS 2X4 OR 2X6 BOTTOM PLATE PER WALL TYPE FLOOR PER PLAN FINISH SCHEDULE EXISTING FLOOR ASSEMBLY PER DETAIL DETAIL: Al WALL TO FLOOR CONNECTION SCALE: V=1'-0" 1X WOOD TRIM TOP RAIL 1 X6 T&G WOOD TREATMENT STAIN: COLOR TBD PAINT BY TENANT COLOR:BLACK-TBD STOP AT BOTTOM OF STAIRS, VERIFY WITH OWNER COLOR & EXENT EXISTING GWB PER LANDLORD (SHELL CORE PERMIT) EXISTING WALL AND FLOOR PER SHELL & CORE PERMIT • ONE LAYER 8" TYPE 'X' GWB • 2X4 WOOD STUD FRAMING @ 16" O.C. • ONE LAYER 8" TYPE 'X' GWB • WALL FINISH PER INTERIOR ELEVATION DETAIL: Al - PARTITION WALL SCALE: V-1'-0" • ONE LAYER 8" TYPE 'X' GWB • 2X4 WOOD STUD FRAMING @ 16" O.C. • 3.5" ACOUSTIC BATT INSULATION • ONE LAYER 8" TYPE 'X' GWB • FRP PANELS TO BE INSTALL BY GC DETAIL: A2 - PARTITION WALL SCALE. 1" 1'-0" N/A SCALE: V -1'-0" • FINISH FLOOR PER PLAN-LVT OR TILE 4" (+/-) PLYWOOD SUB -FLOOR (EXISTING TO REMAIN) • ONE LAYER OFT&GCAR DECKING (ALT DIRECTION) • EXISTING FRAMING PER SHELL & CORE PERMIT ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED n ARCHITECT A. QORE TZ STATE OF W Slit TON RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MO'S PIZZERIA 550 MAIN STREET EDMONDS, WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 WALL DETAILS DATE SCALE DRAWN ETK & FO JOB # 22-037 ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLCs professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. EXISTING WALL TREATMENT- BACK OF BAR SCALE: 1 "=1'-0" EXISTING WALL TREATMENT- PILASTER SCALE: 1 "=1 '-0" EXISTING WALL TREATMENT- STAIRWELL SCALE: V=1'-0" DETAIL: F1 - EXISTING FLOOR SCALE: 1"1'-0" low owl', i 1 1+ p 1 1 1 ■ II ii ■ ■ ■ �1 � i a 1 1 1 1 t ' A II ■ II _j II II aaz�3az � � I r I BAR ELEVATION - NORTH SCALE: 1— 1/2"=T-0" BAR OVERALL lo ol WINE RACK 9'-8 1 /4„ WINE RACK 6'-4 1 /2" 1'4-5/16" 1'4-5/16" �o ----------------------- --------------------------------------- ----------------------------------------- ± 3'-6" ± 2'-7 1 /4" �, ± 3'-5 3/4" V-5 9/16" ± 6-3 1 /4" I, SHELF SHELF SHELF SHELF �12 BAR PLAN A9.01 SCALE :3/4"=V-0" Ilk M M M COUN- SHELF DETAIL SCALE: 1"-1'-0" BAR DIVIDER DETAIL SCALE. 1'1'-0" 3/16" X 2.25 X 1.25" BENT METAL HORIZONTAL UPPERS LED TAPE 16�� METAL PLATE SHELVING - BLACKENED STEEL I LED TAPE I I 3/16" X 1.25" METAL ANGLE SUPPORT (LENGTH OF SHELF) 'ER (SOLID SURFACE) 1 /2" X 2" FLAT BAR, STL 1-1/2" X 2" FLAT BAR, STL ANGLE (E) FLOOR SERVICE COUNTER DETAIL BACK FRP-2 (BLACK) CNT PER FIli SCHEDULE 'LAM PER FIN SCHEDULE ADJUSTABLE SHELVES, 3/4' WOOD TRIM F SCHEDULE e),_r)" BAR DETAIL SCALE: 1 "-1'-0" N/A SCALEMA N/A ,,,_P„ ;NT TOP PER FIN ;CHEDULE 1/4" PLYWOOD )TEEL SUPPORT kNGLE (ROUTE IN 'LYWOOD) :ECESSED )IMMABLE LED -APE LIGHT BOOK AT 4'-0" O.0 'VD-3 VALL PER PLAN .5" DIA. STEEL 'OOT REST WITH kNGLED METAL )UPPORTS AT 'LATE SEAMS OUBLE WD FRAME OP PLATE Z JALL TYPE PER LAN Z J 0- di w " RUBBER BASE Cn RIM JD STUD JOOD BOTTOM LATE SERVICE COUNTER DETAIL FRONT ARCHITECTURE 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 9776 REGISTERED ARCHITECT A. ORE "I G STATE OF W SH] TON RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOH N NY MO'S PIZZERIA 550 MAIN STREET EDMONDS, WAS H I N GTO N 98020 PERMIT SET SUBMITTAL 09.13.2022 CASEWORK DETAILS DATE SCALE DRAWN ETK & FO JOB # 22-037 copyrigl , ©2022 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, Is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or In part without the written authorization of Urbal Architecture, PLLC. _smber SCALE: 1 "=1'-0" SCALE: 1 "-1'-0" UNPUBLISHED WORK 02022 CMA. INC. General Notes • IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS TO VERIFY THE ACTUAL SPACE AND MECHANICALREQUIREMENTS OF ALL ITEMS SHOW AS FUTURE, N.I.C., SUPPLIED BY "OTHERS", ETC. WITH THE OWNER PRIOR TO ROUGH -IN AND CONNECTION • THE GENERAL CONTRACTOR SHALL IMMEDIATELY INFORM CMA RESTAURANT SUPPLY & DESIGN PROJECT MANAGER AND THE OWNER OF ANY RED LINES, CORRECTIONS, ETC. ON THE PERMIT PLANS AND OF ANY INSPECTION CORRECTIONS REQUESTED CONCERNING THESE DRAWINGS OR EQUIPMENT AS LISTED FOR THIS PROJECT. • THE GENERAL CONTRACTOR SHALL PROPERLY SEAL ALL WALL AND FLOOR PENETRATIONS AFTER THE INSTALLATION OF RELATED EQUIPMENT AND FURNISHING. • IT SHALL BE NOTED BY THE GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS THAT THIS SET OF PLANS AND THE INFORMATION CONTAINED WITH -IN IN NOW WAY RELIEVES SAID PARTIES OF THEIR RESPONSIBILITIY TO INVESTIGATE AND COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES, AND TO PERFORM ALL WORK TO THE HIGHEST STANDARDS. • THE GENERAL CONTRACTOR SHALL PROVIDE ALL FLOOR, CEILING, WALL AND ROOF PENETRATIONS AND FIRE RATED SHAFTS FOR EXHAUST DUCTWORK. • IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO PROVIDE WEATHER PROTECTION FOR ALL ROOF AND ALL WALL PENETRATIONS PRIOR TO AND DURING THE INSTALLATION OF EQUIPMENT AND FURNISHINGS. • SUITABLE WALL BACKING AS SHOWN ON THESE PLANS AND AS REQUIRED BY THE OWNER SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. • THE EXHAUST SYSTEM SHALL BE SUBJECT TO A PERFORMANCE TEST AS REQUIRED PRIOR TO ISSUANCE OF BUILDING PUBLIC OCCUPANCY BY LOCAL BUILDING OFFICIALS. • PLANS FOR WALK-IN COOLER SHALL BE SUBMITTED PRIOR TO CONSTRUCTION. • THESE PLANS SHALL BE READ IN CONJUNCTION WITH THE EQUIPMENT CUT SHEET BOOK SUPPLIED BY CMA RESTAURANT SUPPLY & DESIGN, INC. AND BY THIS REFERENCE IS MADE A PART HEROF. 0 ROOF / REMOTE LOCATION SEE ARCHITECTS / ENGINEERS DRAWINGS 39 41� R VALUE OF WALK-IN COOLERS COOLERS - MINIMUM OF R-25 FREEZERS - MINIMUM OF R-32 INCLUDES FLOORS, WALLS AND CEILINGS FREEZERS FLOORS - MINIMUM OF R-28 VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMENT SELECTIONS 39 H ry W 1 N N N 1 Co T1 V J O 2 CD co CD co m Cu Cu C) u') (n u') _0 0 E w RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 Z Z C� Cn W 0 0 z Q Q (D V ) ui L.L Cn CM M CV M N 00 � Cl)LO ti CO Cn O CV N 1� U U O Y Cn N U � C[3 E_ � U s CD LLI Z J 00 Q Lu Q n w I� V w z w U Date: 5-31-2022 JG WINTER Scale: 1 /4"= V-0" Project #: 1601 o z E PROVIDED BY CY Description ELECTRICAL PLUMBING Notes Y 0 W z O Y a Q 1 2 1 �, 7 H IL = 0 c U = V a� N u7 0 a m 1 X 1 SERVICE COUNTER 2 X 2 POINT OF SALE TERMINAL 3.0 115 1 DCO DEDICATED/ ISOLATED, VERIFY REQUIREMENTS WITH OWNER 2.1 X 3 TICKET PRINTER X 115 1 DCO DEDICATED/ ISOLATED, VERIFY REQUIREMENTS WITH OWNER 3 X 1 UNDER COUNTER REFRIGERATOR X 115 1 DCO NEMA 5-15P 4 X 2 WIRE TO GO SHELVING 5 X 1 FRONT BAR TOP AND DIE WALL 6 X 1 ICE WELL WITH COLD PLATE 1" INDIRECT WASTE 7 X 3 SODA DISPENSING GUN 3.0 115 1 DCO 1/2" 8 X 1 PERFORATED DRINK PICK UP TRAY 1" INDIRECT WASTE 9 X 3 DRAIN BOARD WITH STORAGE BELOW 1" INDIRECT WASTE 10 X 1 MIXING RAIL 1/2" 11 X 1 JOCKEY BOX WITH COLD PLATE 1" INDIRECT WASTE 12 X 1 M IXOLOGY STATION 1/2" 1/2" 1 1/2" INDIRECT WASTE 13 X 1 HAND SINK 1/2" 1/2" 1 112" DIRECT WASTE 14 X 1 DUMP SINK 1/2" 112" 1 1/2" INDIRECT WASTE 15 X 1 GLASS WASHER 38.4 208 1 JBOX 1/2" 1" INDIRECT WASTE 16 X 1 BACK BAR COUNTER AND UPPER DISPLAY 17 X 2 BACK BAR REFRIGERATOR 6.5 115 1 DCO 18 X 1 BEER TAPS WITH DRAINER / RINSER 1/2" 1" INDIRECT WASTE 19 X 1 FREEZER 5.4 115 1 DCO 20 X 1 BAG N BOX RACK 21 X 1 CO2 TANK NOTE # 18 22 SPARE NUMBER 23 SPARE NUMBER 24 SPARE NUMBER 25 SPARE NUMBER 26 SPARE NUMBER 27 SPARE NUMBER 28 SPARE NUMBER 29 SPARE NUMBER 30 X 1 STORAGE SHELVING 31 X 1 PICKUP COUNTER PASS SHELF 32 SPARE NUMBER 33 X 1 WORK TOP REFRIGERATOR X 115 1 DCO NEMA 5-15P 34 X 2 RAISED RAIL REFRIGERATOR X 115 1 DCO NEMA 5-15P 35 X 1 WORK TABLE 36 X 1 WIRE WALL SHELVING 37 SPARE NUMBER X 115 1 JBOX 38 X 1 EXHAUST DUCTWORK 39 X 1 CLASS I EXHAUST FAN X X X JBOX 40 SPARE NUMBER 41 SPARE NUMBER 42 SPARE NUMBER NOTE XX 43 SPARE NUMBER 44 X 2 DOUBLE STACK DECK OVEN X 115 1 DCO 314' X VERIFY REQUIREMENTS OF EXISTING EQUIPMENT 45 X 2 HAND SINK 1 1/2" DIRECT WASTE 46 X 2 FAUCET 1/2" 1/2" 47 X 2 HAND SOAP / TOWEL DISPENSER 48 X 1 MOBILE PAN RACK 49 X 1 WORK TABLE 50 X 1 WIRE WALL SHELVING 51 X 1 DOUGH STORAGE LUG 52 SPARE NUMBER 53 SPARE NUMBER 54 SPARE NUMBER 55 SPARE NUMBER 56 SPARE NUMBER 57 SPARE NUMBER 58 SPARE NUMBER 59 SPARE NUMBER 60 X 1 REACH -IN FREEZER X 115 1 DCO 61 X 1 SOILED DISH TABLE WITH PRE -RINSE SINK 2" DIRECT WASTE 62 X 1 SLANT RACK SHELF 63 X 1 PRE -RINSE FAUCET 1/2" 1/2" 64 X 1 DISHWASHER X X X JBOX X X INDIRECT WASTE 65 X 1 THREE COMPARTMENT SINK 66 X 1 GREASE INTERCEPTOR 67 X 1 FAUCET 3/4" 3J4" 68 X 1 WIRE WALL SHELVING 69 X 1 WALK-IN COOLER 4.0 115 1 JBOX FOR LIGHTS 70 X 1 BLOWER COIL 1.6 115 1 JBOX 1/2" INDIRECT WASTE 71 X 1 COMPRESSOR 19.6 208 3 JBOX 72 X 1 WALK-IN COOLER SHELVING 73 X 2 MOBILE PAN RACK 74 SPARE NUMBER 75 SPARE NUMBER 76 SPARE NUMBER 77 SPARE NUMBER 78 SPARE NUMBER 79 SPARE NUMBER 80 X 1 MOP SINK 2" DIRECT WASTE 81 X 1 FAUCET 1/2" 1/2" 82 X 1 MOP / BROOM SHELF 83 X 2 STAINLESS STEEL CORNER GUARD 84 X 1 WATER HEATER 85 X 1 ICE MACHINE X 208 3 JBOX 3/4" 2" INDIRECT WASTE 86 X 1 ICE STORAGE BIN 2" INDIRECT WASTE 87 X 1 DRY STORAGE SHELVING 88 X 2 PREP SINK 1 1/2" 89 X 2 FAUCET 1/2" 1/2" 90 X 1 WIRE WALL SHELVING 91 X 1 WOOD TOP WORK TABLE 92 X 1 DOUGH BALLER X X X X 93 X 3 INGREDIENT BINS X 208 X X 94 X 1 M IXER General Notes 1. THE ELECTRICAL CONTRACTOR SHALL SLIPPY AND INSTALL SEAL-TITE FLEX CONDUIT TO ALL FOOOD SERVICE EQUIPMENT IN DAMP AREAS, I.E. SCULLERY, BAR, ROOF, ETC. FLEX CONNECTIONS AT ALL FANS ON THE ROOF SHALL BE OF EXTRA LENGTH TO ALLOW FULL FAN REMOVAL FOR THE EASE OF CLEANING. 2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT HOOK-UPS AS REQUIRED BY CODE AND LABELING. 3. THE ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS IN A CONVENIENT ACCCESSIBLE LOCATION AT THE POWER BOX FOR EACH ICE MACHINE HEAD. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A VAPOR -PROOF SW ITH AT EACH BLOWER COIL IN THE WALK-IN COOLER (ITEM #70). S. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A 48" MINIMUM CORD AND PLUG FOR EACH PIECE OF EQUIPMENT SO NOTED. USE 90 DEGREE ELBOW OUT OF UNIT. 6. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FOR HOOK-UP OF A THERMOSTAT, SOLENOID, BLOWER COIL AND COMPRESSOR FOR EACH REFRIGERATED UNIT. MAGNETIC STARTERS AND/OR THERMAL PROTECTORS SHALL BE INCLUDED AS NECESSARY. 7. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL HEAT TAPE ON ALL DRAIN LINES SUBJECTTO THE POSSIBILITY OF FREEZING. 8. IT SHALL BE THE RESPONSIBILITY OF "OTHERS" TO INTERCONNECT THE HOOD FIRE PROTECTION SYSTEMS TO THE BUILDING FIRE DETECTIONS SYSTEMS AS REQUIRED. 9. THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALLTO EACH PIECE OF ROOF -TOP EQUIPMENT (FANS, MOTORS, COMPRESSORS, CONDENSORS, ETC.) ASEPARATE WEATHER -PROTECTED DISCONNECT SWITCH. 10. IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING AND ELECTRICAL CONTRACTORS TO MAKE ALL REQUIRED WATER, GAS, DRAIN AND ELECTRICAL CONNECTIONS FOR ALL MAKE-UP AIR SYSTEM UNITS. 11. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO INSTALL ALL OWN ER SUPPLIED COMPUTER / COMMUNICATION CABLES AS PER OWNERS' DIRECTION. 12. ELECTRICAL CONTRACTOR SHALL PROVIDE AN INDIVIDUAL DISCONNECT BOX FOR EACH PIECE OF ROOFTOP ELECTRICALLY POWERED EQUIPMENT. 13. THE GENERAL CONTRACTOR SHALL PHOTOGRAPH ALL WALLS CONTAINING BACKING PRIOR TO SHEETROCK / FRP INSTALLATION. 14. THE ELECTRICAL CONTRACTOR SHALL PROVIDE 1" CONDUIT AND JUNCTION BOXES AT EACH CASH REGISTER TERMINAL SO AS TO INTERCONNECT ALL UNITS TO EACH OTHER AND TO THE CENTRAL PROCESSING TERMINAL. CONSULT WITH THE OWNER'S REPRESENTATIVE FOR EXACT LOCATIONS OF ALL TIE-IN UNITS. 15. COMMUNICATION CABLES ARE SUPPLIED AND INSTALLED BY ELECTRICAL CONTRACTOR. 16. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO INSTALL ALL OWNER SUPPLIED COMPUTER / COMMUNICATION CABLES AS PER OWNERS' DIRECTION. 17. ELECTRICAL CONTRACTOR SHALL PROVIDE AN INDIVIDUAL DISCONNECT BOX FOR EACH PIECE OF ROOFTOP ELECTRICALLY POWERED EQUIPMENT. 18. THE GENERAL CONTRACTOR SHALL PHOTOGRAPH ALL WALLS CONTAINING BACKING PRIOR TO SHEETROCK / FRP INSTALLATION. 19. THE ELECTRICAL CONTRACTOR SHALL PROVIDE INTERCONNECT SWITCHING BETWEEN THE KITCHEN EXHAUST HOOD FANS AND THE KITCHEN MAKE-UP AIR SYSTEMS AS REQUIRED BY LOCAL CODES AND AUTHORITIES. 20. ALL DRAIN LINES FROM EQUIPMENT REQUIRING CONDENSATION REMOVAL SHALL BE DONE IN COPPER. 21. THE PLUMBING CONTRACTOR SHALL PROVIDE CLEANOUTS AT 1ST ELBOW ON EACH WALK-IN BLOWER COIL DRAIN. 22. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL ALL DRAIN LINES FROM WALK-IN BLOWER COILS TO FLOOR SINKS. 23. IT SHALL BE THE RESPONSIBILTY OF PLUMBING CONTRACTOR TO COMPLY WILL ALL LOCAL CODES CONCERNING GAS VALVE REGULATOR VENTING. 24. PRESSURE REGULATOR'S FOR GAS COOKING EQUIPMENT ARE SUPPLIED BY CMA AND INSTALLED BY PLUMBING CONTRACTOR PER CODE AND MANUFACTURER'S SPECIFICATIONS. 25. THE PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL WATER LINE BACK CHECK VALVES AS REQUIRED PER CODE. THE OWNER'S VENDOR OF CHOICE SHALL SUPPLY AND INSTALL A CO2 STORAGE CANISTER IN THE LIQUOR STORAGE ROOM, AN EXTERIOR FILL VALVE AND ALL CO2 UNITS SHALL BE SUPPLIED AND INSTALLED BY THE VENDOR Illl- �ui V ) Of i n 0i UNPUBLISHED WORK CQ2022 CMA. INC. 00 CD 00 m 0 (3) 0 L m G O 0 u) _0 � L77 O E L1J co M co N O N CO I co I- Ln -;:t M I� 9 Ln O N N V U U 0 I I I Z z co TZ] z I v Ii Q co CD 00 ! E I W c T I < n CL U) Z Q Y to m U E i (6 I a U 1 Z s 9 i VJ z J LLJ N W LJ J J M LJJ U U) I- Z W LJJ z LIJ U Date: 5-3131-2022 JGRESAJ B Nov ^^II((��^^IICC Scm0; 6M1` NE,S DEPARTMENT Project #: 1601 ELECTRICAL 1. THE CONTRACTOR ' COVERS IN ALL KIT( 2. THE ELECTRICAL CC REFRIGERATION TH eai re10smalm rNrv.�r�r� DISCONNECTS, MAGNETIC STARTERS, AND THERMAL OVERLOAD PROTECTION AS REQUIRED. 4. THE ELECTRICAL CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWN ON THESE PLANS ARE FOR FOOD SERVICE EQUIPMENT ONLY. SEE THE ARCHITECT'S PLAN SET FOR ALL OTHER ELECTRICAL REQUIREMENTS FOR THIS PROJECT. S. ALL ELECTRICAL ROUGH -IN WORK AND FINAL CONNECTIONS FOR ALL ITEMS SHOWN AND SPECIFIED ON THESE PLANS BY CMA RESTAURANT SUPPLY & DESIGN SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR. 6. UNLESS OTHERWISE SPECIFIED IN THESE PLANS OR OTHER WRITTEN CONTRACTS, IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL TYPE MATERIALS, INCLUDING WIRING, SWITCHES, DISCONNECTS, FLEX, CONDUIT, CONTACTORS, TRANSFORMERS, THERMAL OVERLOAD PROTECTORS, MAGNETIC STARTERS, ELECTRICAL PANELS, CORDS, PLUGS, COVERS, ETC. 7. ALL DIMENSIONS SHOWN ARE FROM GRID LINES, FINISHED WALLS OR FINISHED FLOORS TO CENTER LINE OF ELECTRICAL BOXES. HEIGHTS ARE NOT TO BE TAKEN FROM CURBS OR PLATFORMS. 8. THE SYMBOLS SHOWN ON THIS PLAN ARE FOR INDICATION OF ROUGH -IN LOCATION AND TYPE OF CONNECTION ONLY. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUITS AND CONDUIT RUNS AS PER GOOD PRACTICE AND CODE. 9. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT HOOK- UPS AS REQUIRED BY CODE AND LABELING 10. THE ELECTRICAL CONTRACTOR SHALL PROVIDE "HOMERUN" CONDUIT TO COMPUTER FROM POINT OF SALE TERMINAL TO OFFICE. VERIFY LOCATION WITH OWNER. 11 12 13 241-01 „ 12 -0 I 2 I ROOF SEE ARCH IECTURAL OR MECHANICAL DRAWINGS 39 71 VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMENT SELECTIONS GFCI RECEPTACLES SHALL BE PASS & SEYMOUR N0. 2097W ELECTRICAL LEGEND 115 VOLT DUPLEX OUTLET DI � 115 VOLT DCO, DEDICATED/ISOLATED 208V SPECIALTY OUTLET JUNCTION BOX COIV® FY SPEC'S ANNDM EQU RTEONS MENTSAWITH OWNER ON/OFF SWITCH _0 LIGHT FIXTURE BY K.E.C. AND INSTALLED BY ELECTRICAL CONTRACTOR 1 UNPUBLISHED WORK ©2022 CMA. INC. 0 00 0 00 rn (n '� 0 (I)o >1 .� JCO o LO v) 0 E w RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Lnn Ln M 6) N c� M co V co fl_ co Ln O N N � U U 0 O a7 Z Z I U co J1 0 0 I Q C M O I J co o i o U I � T C _ ^ I j 7 > � C Z3 Y (6 I 7 I QN Y U) � U E _- L V! Z J Lu i Lu Z Q J z i ZD 0 ry J Q U_ Of F— U Lu Lu z Lu U Date: 9-4-2022 JG WINTER Scale: 1 /4"=1'-0" Project #: 1601 PLUMBING NO 1. IT IS THE PLUMBING CO(` INTERCEPTOR/ TRAP IF ( 2. ALL FIRE PROTECTIONS' INSTALLED BYTHE PLUM 3. THE PLUMBING CONNEC ARE FOR THE FOOD SER1 PLUMBING REQUIREMENTS FOR THIS PROJECT. 4. ALL PLUMBING ROUGH -IN WORK AND FINAL CONNECTIONS FOR ALL ITEMS SHOWN AND SPECIFIED ON THESE PLANS BY CMA RESTAURANT SUPPLY & DESIGN SHALL BE PERFORMED BY THE PLUMBING CONTRACTOR. S. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL INSULATION MATERIAL ON ALL DRAIN LINES FROM ICE BINS, ICE PANS, ETC. SO AS TO ELIMINATE CONDENSATION FORMATION. 6. UNLESS OTHERWISE SPECIFIED IN THESE PLANS OR OTHER WRITTEN CONTRACTS, IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO PROVIDE ALL PLUMBING -TYPE MATERIALS INCLUDING VALVES, TRAPS, LINE STRAINERS, FLOOR SINK COVERS, PRESSURE REGULATORS, SIPHON BREAKERS, ETC. 7. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFYTHAT THE LOCATIONS FOR ALL MECHANICAL REQUIREMENTS WHICH REQUIRE FLOOR PENETRATIONS DO NOT CONFLICT WITH STRUCTURAL MEMBERS IN THE FLOOR. 8. THE GENERAL CONTRACTOR SHALL SUPERVISE THE LOCATION OF ALL FLOOR DRAINS ON THE PROJECT SO AS TO ENSURE THE BEST SLOPE POSSIBLE OF THE SURROUNDING FLOOR TO THESE DRAINS. 9. ALL DRAIN LINES FROM EQUIPMENT REQUIRING CONDENSATION REMOVAL SHALL BE RUN IN COPPER. 10, PLUMBING CONTRACTOR TO SUPPLY WATER PRESSURE REDUCING VALVE SET AT 20 PSI FOR EACH DISH WASHER AND GLASS WASHER. PLUMBING LEGEND o CW-COLD WATER o F CW-COLD WATER - FILTERED o HW-HOT WATER ® CLOSED DRAIN - DIRECT WASTE ES 12" X 12" FLOOR SINK INDIRECT WASTE NATURAL GAS ED O FLOOR DRAIN VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMENT SELECTIONS 1 CV CV 0 N 1 1 UNPUBLISHED WORK (D2022 CMA. INC. C) 00 CD 00 (n �--r O (1)o JC OL0 O -0 � LO O E w RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ar Ln M 6) N co M co V co fl_ co Ln O N N � U U O U Z Z 0 co 0 I I Q C M O co � � I I E CZ Z:3 � Cn _ I VZ` Y U ` E d ^ V! W '� Z J LLJ i Z Q J r z O re J Q U_ z Q U Cw G z ui U Date: 9-4-2022 JG WINTER Scale: 1 /4"=V-0" Project #: 1601 5/8" GYP. SHEETROCK WALL FINISH MATERIAL (EXCEPT PAINT) PER ARCHITECT'S DRAWING (EXCEPT PAINT) 5/8" PLYWOOD PER WALL BACKING PLAN WALL FRAMING PER ARCHITECT'S DRAWINGS 5/8" GYP. SHEETROCK PLYWOOD BACKING DETAIL SCALE. NONE 12 13 24'-0 1 " I 2 I I --—————————————————————————————————————————————L—————————————————- I I I I I V�RIRY EQUIPMENT REQUIREVENTS WITH FINAL EQUIPMENT SELECTIONS WALL BACKING NOTES: 1. GENERAL CONTRACTOR SHALL CONSULT WITH OWNER AND CMA RESTAURANT SUPPLY AT THE TIME OF LAYOUT FOR WALL BACKING CONFIRMATION OF ALL DIMENSIONS OF ALL AND UP -DATE REQUIREMENTS. 2. WALL BACKING TO BE USED FOR WALL MOUNTED EQUIPMENT AND SHELVES. 3. WALL BACKING TO BE 5/8" PLYWOOD. 4. WALL WALL BACKING TO BE BUILT INTO WALL SO THAT FINISH WALL IS FLUSH SURFACE. C) i O i N UNPUBLISHED WORK ©2022 CMA. INC. O 00 O 00 rn O (1)o VJ 0�^^ w ' O E W RECEIVED Sep 14 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Cn M CM N 6) N co I- LO co� CO Ln O N N � U U O I i , U I Z Z (D U) W 0 I Q rr—n a Cl) O O rn E I J �.2� 0 I iE a co U) c 7 YN (B Z Y w E �EI �(aJ� I �� V) Lu J Z00 I I N Lu z Q J 0- z U Q m J J Q Z W U Date: 9-5-2022 JG WINTER Scale: 1/4"=1'-0" Project #: 1601