APPROVED BLD RESUB 1-Architectural_Plan+12.6.2021PROJECT ADDRESS:
9532 231 ST PL SW, EDMONDS, WA
TAX ACCESSOR'S PARCEL NUMBER:
27033600111000
LEGAL DESCRIPTION:
SEC 36 TWP 27 RGE 03 W 75FT OF
SW1/4 SW1/4 NE1/4 NE1/4 EXC S
174FT THOF (AKA LOT 2 OF SP 74
(3-81) AF 8109240110)
PROPERTY OWNER:
MCKINLEY'S
9532 231 ST PL SW, EDMONDS,
WA, 98020
CONTACT: HALEY MCKINLEY
206-919-7975
CONTACT: MAX MCKINLEY
206-819-4035
PROJECT TEAM
GENERAL CONTRACTOR:
PEAK GENERAL CONTRACTING
PEAKGGC804CC
CONTACT: BRANDON BOEHM
206-890-0043
STRUCTURAL ENGINEER:
BYKONEN, CARTER, QUINN
2033 SIXTH AVENUE, SUITE 995
SEATTLE, WA 98121
CONTACT: NICK CARTER, PE
206-264-7784 EXT 203
PROJECT SUMMARY:
SCOPE OF WORK LIMITED TO
INTERIOR ALTERATIONS/REMODEL.
1ST FLOOR: KITCHEN, LIVING ROOM,
DINING ROOM, FAMILY ROOM &
POWDER
2ND FLOOR: PRIMARY BATHROOM
ADDITIONAL STRUCTURAL
rPLANS TO BE ON SITE AT
rTIME OF INSPECTION
APPROVED
PLANS MUST BE
ON JOB SITE
,Labor&Industries (https://Ini.wa.gov)
Contractors
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
SHEET INDEX
A0.0
PROJECT DATA
A0.1
GENERAL NOTES
A2.0
LEVEL 1 &LEVEL 2
A2.1
LEVEL 1
A2.2
LEVEL 2
S1.0
GENERAL STRUCTURAL NOTES
S2.0
FOUNDATION PLAN
S2.1
LEVEL 2 FRAMING PLAN
S2.2
ROOF FRAMING PLAN
S3.0
DETAILS
City Of Edmonds
Building Department
Work r INTERIOR REMODEL
------------------------------------------------
Address 9532 231ST PL SW
Owner MCKINLEY
Approved Date 12/14/2021
Building Official � � w. � p�iiasc
-------------------------- - - ----------------
Permit Number; BLD2021-1493
THERE IS NO PLUMBING PERMIT ASSOCIATED
WITH THIS PERMIT.
PEAK GENERAL CONTRACTING LLC
Owner or tradesperson
2212 QUEEN ANNE AVE N
....................... _ .....
Principals
#337
BOEHM, GREGORY
SEATTLE, WA 98109
CHARLES, PARTNER/MEMBER
206-499-2185
KING County
BOEHM, JULIE
YEARIAN, PARTNER/MEMBER
Doing business as
PEAK GENERAL CONTRACTING LLC
WA UBI No.
Business type
604 521 781
Limited Liability Company
Governing persons
GREG
CHARLES
BOEHM
JULIE YEARIAN BOEHM;
License
Verify the contractor's active registration /license /certification (depending
on trade) and any past violations.
Construction Contractor
Active
... _ ........................
Meets current requirements.
. ��o� s�,e mPa�e�. m
Labor &Industries (https://Ini.wa.gov).
Contractors
MATERIAL SYMBOL LEGEND
��'�i�y : � � �
CMU /BRICK /STONE /VENEER
� CONCRETE
EARTH /COMPACT FILL
FINISH WOOD
��� ��� � GRAVEL /POROUS FILL
�i
GYPSUM WALL BOARD /PLASTER
NATURAL STONE
PLYWOOD
--------
1........ � � •
ROUGH WOOD FRAMING
STEEL OR OTHER METAL
WOOD BLOCKING
Northwest Plmbng Solutions LLC
Owner or tradesperson
3904 S 254TH ST
Principals
KENT, WA 98032
DENISYUK, ALEKSANDR
206-228-1293
KING County
V, PARTNER/MEMBER
DENISYUK, ALLA P, PARTNER/MEMBER
Doing business as
Northwest Plmbng Solutions LLC
WA UBI No.
Business type
603 011 702
Limited Liability Company
Governing persons
ALEKSANDR
V
DENISYUK
ALLA D DENISYUK;
License
Verify the contractor's active registration /license /certification (depending on trade) and any past violations.
Construction Contractor
Active
Meets current requirements.
� License specialties
License specialties
GENERAL
GENERAL
License no.
License no.
NORTHPS903L1
PEAKGGC804CC
Effective —expiration
Effective —expiration
O6/21/2010— 06/21/2022
02/03/2020— 02/03/2022
Bond
Bond
Contractors Bonding &Insurance Co
$12,000.00
American Contractors Indem CO
$12,000.00
Bond account no.
Bond account no.
SI6576
100476004
Received by L&I
Effective date
Received by L&I
Effective date
07/05/2011
O6I30I2011
02I03/2020
01/01I2020
Expiration date
Expiration date
Until Canceled
Until Canceled
Insurance
_Insurance
Western National Assur Co
$1,000,000.00
Developers Surety &Indem Co
$1,000,000.00
Policy no.
Policy no.
BOP1002846.02
BIS0003432901
Received by L&I
Effective date
Received by L&I
Effective date
08/06/2021
09/22/2017
12117/2020
01/30/2020
Expiration date
Expiration date
09/22/2022
01 /30/2022
Savings
_............
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
I Certifications &Endorsements I
OMWBE Certifications
No active certifications -exist for this business.
Apprentice Training Agent
No active Washington registered apprentices exist for this business. Washington allows the use of apprentices
registered with Oregon or Montana. Contact the Oregon Bureau of Labor &Industries or Montana Department of Labor
& Industry to verify if this business has apprentices.
Workers' Comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID Account is current.
801,748-00
Doing business as
PEAK GENERAL CONTRACTING LLC
Estimated workers reported
Quarter 2 of Year 2021 "1 to 3 Workers"
L&I account contact
T5l JAVIER PAREDES (360)902-4639 -Email: PAJB235@Ini.wa.gov
Public Works Requirements
Verify the contractor is eligible to perform work on public works projects.
Required Training— Effective July 1, 2019
Needs to complete training.
Contractor Strikes
...............
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace Safety &Health
Check for any past safety and health violations found on jobsites this business was responsible for
No inspections during the previous 6 year period.
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
..... ..............
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
I Certifications &Endorsements I
OMWBE Certifications
No active certifications exist for this business
Apprentice Training Agent
No active Washington registered apprentices exist for this business. Washington allows the use of apprentices
registered with Oregon or Montana. Contact the Oregon Bureau of Labor &Industries or Montana Department of Labor
& Industry to verify if this business has apprentices.
Workers' Comp I
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID Account is current.
217,220-00
Doing business as
NORTHWEST PLUMBING SOLUTIONS
Estimated workers reported
Quarter 2 of Year 2021 "1 to 3 Workers"
L&I account contact
T3 / DAVID PRYOR (360)902-4804 -Email: PRYD235@Ini.wa.gov
Public Works Requirements
Verify the contractor is eligible to perform work on public works projects.
Required Training— Effective July 1, 2019
Needs to complete training.
Contractor Strikes
......................................
No strikes have been issued against this contractor.
Contractors not allowed to bid
...............
No debarments have been issued against this contractor.
Workplace Safety &Health
Check for any past safety and health violations found on jobsites this business was responsible for
No inspections during the previous 6 year period.
FOR PERMIT
ONLY
THIS DOCUMENT HAS BEEN
PREPARED FOR PERMIT
APPLICATION AND IS SUBJECT TO
REVIEW AND MODIFICATION BY
GOVERNMENTAL AGENCIES
11 /22/2021
ALL DRAWINGS, SPECIFICATIONS, PLANS, AND
DESIGNS REPRESENTED OR REFERRED TO ARE
THE PROPERTY OF AND OWNED BY COASTAL
CIRCLE, LLC. WHETHER THE PROJECT FOR WHICH
THEY ARE MADE IS EXECUTED OR NOT, THEY WERE
CREATED, DEVELOPED, AND PRODUCED FOR THE
SOLE USE ON AND IN CONNECTION WITH THIS
PROJECT AND NONE OF THE ABOVE MAYBE
DISCLOSED OR GIVEN TO OR USED BY ANY
PERSON, FIRM, OR CORPORATION FOR ANY USE OR
PURPOSE WHATSOEVER INCLUDING ANY OTHER
PROJECT, EXCEPT UPON WRITTEN PERMISSION OF
COASTAL CIRCLE, LLC.
COASTAL CIRCLE
•
INFO@COASTALCIRCLE.COM
w
Z
O
J
I—
r
M
N
N
'M^
r�\/
V/
RESUB
Dec o� 2o�TED
CITY OF EDMONDS
DEVELOPMENT SERVICES�AL
DEPARTiNENT— �
STAMP S PAC E
PROJECT
• •1
9532 231ST PL SW,
EDMONDS, WA
PERMIT SET
PERMIT #
DATE 11 /22/2021
A-
Scale As indicated
GENERAL NOTES
• ALL WORK TO COMPLY WITH INTERNATIONAL RESIDENTIAL
CODE AND INTERNATIONAL BUILDING CODE WITH
AMENDMENTS WHERE APPLICABLE.
• ALL APPLICABLE CODES, ORDINANCES, AND MINIMUM
STRUCTURAL REQUIREMENTS TAKE PRECEDENCE OVER ALL
DRAWINGS, NOTES, AND SPECIFICATIONS.
• DO NOT SCALE DRAWINGS; ALWAYS USE PRINTED
DIMENSIONS ONLY. ALWAYS NOTIFY ARCHITECT OF ANY
OMISSIONS OR DISCREPANCIES BEFORE PROCEEDING WITH
WORK IN QUESTION.
• CONTRACTOR MUST CONTACT ARCHITECT IMMEDIATELY FOR
ANY DISCREPANCIES IN CONTRACT DOCUMENTS OR
EXISTING CONDITIONS PRIOR TO PROCEEDING WITH WORK.
• CONTRACTOR MUST CONTACT ARCHITECT IMMEDIATELY FOR
ANY DISCREPANCIES BETWEEN CONTRACT DOCUMENTS
AND APPLICABLE CODES PRIOR TO PROCEEDING WITH
WORK.
• CONTRACTOR TO VERIFY ALL DIMENSIONS, GRADES, AND
EXISTING CONDITIONS BEFORE PROCEEDING WITH WORK.
• CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE
HIMSELF/HERSELF WITH ALL ASPECTS OF THE WORK PRIOR
TO CONTRACTING WITH THE OWNER TO PERFORM THE
WORK.
• CONTRACTOR SHALL VERIFY CONFORMANCE OF ACTUAL
SOIL CONDITIONS WITH SOILS REPORT AND DESIGN
ASSUMPTIONS.
• CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING ALL
NECESSARY PERMITS FOR THE WORK, EXCEPT FOR THE
BUILDING PERMIT WHICH IS THE RESPONSIBILITY OF THE
ARCHITECT.
• GUARANTEE ON ALL MATERIALS AND WORKMANSHIP TO BE
(1) YEAR FROM DATE OF COMPLETION UNLESS NOTED
OTHERWISE IN THE CONTRACT.
• REPETITIVE FEATURES MAY BE DRAWN ONLY ONCE, BUT
SHALL BE PROVIDED IN FULL. REPETITIVE NOTES MAY BE
CALLED OUT ONLY ONCE AND INDICATE AS TYPICAL.
• DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE
OR CENTERLINE OF INTERIOR COLUMNS UNLESS NOTED
OTHERWISE.
• CONTRACTOR IS RESPONSIBLE FOR COORDINATING
MECHANICAL, ELECTRICAL, AND PLUMBING CONTRACTORS
AND NOTIFYING THE ARCHITECT OF ANY DISCREPANCIES IN
FRAMING PRIOR TO PROCEEDING WITH WORK.
• ALL MECHANICAL, ELECTRICAL, &PLUMBING IS TO BE
DESIGN -BUILD FOR THIS PROJECT.
JOBSITE SAFETY
• ARCHITECT HAS NOT BEEN RETAINED OR COMPENSATED TO
PROVIDE DESIGN AND/OR CONSTRUCTION REVIEW
SERVICES RELATING TO THE CONTRACTOR'S SAFETY
PRECAUTIONS.
• PERIODIC SITE VISITS PERFORMED BY THE ARCHITECT
SHALL NOT BE CONSTRUED AS SUPERVISION OF ACTUAL
CONSTRUCTION SAFETY PRECAUTIONS.
• ARCHITECT IS NOT RESPONSIBLE FOR PROVIDING A SAFE
PLACE FOR THE PERFORMANCE OF WORK BY THE
CONTRACTOR OR THE CONTRACTOR'S EMPLOYEES OR
EMPLOYEES OF SUPPLIERS OR SUBCONTRACTORS, OR FOR
ACCESS, VISITS, USE, WORK, TRAVEL, OR OCCUPANCY BY
ANY PERSON.
SITE WORK
• ALL EXCAVATION AND FILL SHALL BE STORED AND
PROTECTED SUCH AS TO PREVENT RUN OFF OF MATERIAL
TO ADJACENT PROPERTIES.
• FOOTING DRAIN TO BE SEPARATE FROM ROOF AND
IMPERVIOUS AREA DRAINS.
• DOWNSPOUT DRAIN TO BE 4" DIAMETER TIGHTLINE UNLESS
NOTED OTHERWISE.
• FOOTING DRAIN TO BE 4" DIAMETER PERFORATED PIPE
UNLESS NOTED OTHERWISE.
• CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH
REQUIRED SEPTIC AND/OR STORM WATER DETENTION
SYSTEMS.
EARTH WORK
• SEE GEOTECHNICAL REPORT FOR ADDITIONAL
REQUIREMENTS.
• EXTEND EXCAVATION DOWN TO UNDISTURBED SOIL OF THE
SPECIFIED STRENGTH WITH A MINIMUM OF 18" BELOW
LOWEST ADJACENT FINISHED GRADE.
• COMPACTED FILL TO BE WELL GRADED AND GRANULAR WITH
NOT MORE THAN 5% PASSING A 200 SIEVE. PLACE IN 8"
LOOSE LIFTS AND COMPACT TO 95% MODIFIED AASHO
DENSITY AT OPTIMUM MOISTURE CONTENT.
• BACKFILL BEHIND ALL RETAINING WALLS WITH FREE
DRAINING GRANULAR FILL AND PROVIDE FOR SUBSURFACE
DRAINAGE AS NOTED IN THE SOILS REPORT.
ENERGY NOTES
• ALL WORK TO COMPLY WITH 2O18 WASHINGTON STATE
ENERGY CODE, WITH AMENDMENTS WHERE APPLICABLE.
• HEATING UNITS) TO MAINTAIN 70 DEGREES FAHRENHEIT AT
36" ABOVE FLOOR WHEN OUTSIDE TEMPERATURE IS 24
DEGREES FAHRENHEIT, OR CURRENT REQUIREMENTS.
• PROVIDE PROGRAMMABLE THERMOSTATS.
• CAULK ALL JOINTS AROUND EXTERIOR OPENINGS AND ALL
JOINTS IN SIDING AND FLASHING WHERE INFILTRATION MAY
BE POSSIBLE.
• SEAL ALL TEARS AND JOINTS IN INSULATION WITH
APPROVED TAPE.
• SHOWER FLOW CONTROL LIMITED TO 2.5 GALLONS PER
MINUTE, OR CURRENT REQUIREMENTS.
• FIREPLACE(S) SHALL HAVE TIGHT FITTING DAMPERS AND
SHALL BE PROVIDED WITH A MINIMUM OF 6 SQUARE INCHES
OF OUTSIDE COMBUSTIBLE AIR SUPPLY.
• SERVICE WATER PIPES LESS THAN 2" IN DIAMETER SHALL BE
WRAPPED WITH 1" MINIMUM LAYER OF INSULATION PER 2018
WASHINGTON STATE RESIDENTIAL ENERGY CODE.
• ELECTRIC WATER HEATER SHALL HAVE A MINIMUM EF OF
0.93. ALL SHOWERHEAD AND KITCHEN SINK FAUCETS
INSTALLED IN THE HOUSE SHALL BE RATED AT 1.75 GPM OR
LESS. ALL OTHER LAVATORY FAUCETS SHALL BE RATED 1.0
GPM OR LESS.
• VAPOR RETARDER SHALL BE INSTALLED ON THE
CONDITIONED ROOM SIDE OF THE INSULATION.
• A MINIMUM OF 75% OF PERMANENTLY INSTALLED LAMPS IN
LIGHTING FIXTURES SHALL BE HIGH EFFICIENCY LAMPS. ALL
EXTERIOR LUMINAIRES SHALL BE HIGH EFFICIENCY
LUMINAIRES.
• DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE
BUILDING INSPECTOR AND HOMEOWNER PRIOR TO AN
APPROVED FINAL INSPECTION.
• A RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE IS
REQUIRED TO BE COMPLETED BY THE DESIGN
PROFESSIONAL OR BUILDER AND PERMANENTLY POSTED
WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL
INSPECTION.
• BUILDING AIR LEAKAGE TESTING, DEMONSTRATING THE
SPECIFIC LEAKAGE AREA IS LESS THAN OR EQUAL TO .00030,
IS REQUIRED PRIOR TO FINAL INSPECTION. THE TEST
RESULT SHALL BE POSTED ON THE RESIDENTIAL ENERGY
COMPLIANCE CERTIFICATE.
• A SIGNED AFFIDAVIT DOCUMENTING THE DUCT LEAKAGE
TEST RESULT SHALL BE PROVIDED TO THE BUILDING
INSPECTOR PRIOR TO AN APPROVED FINAL INSPECTION.
VENTILATION NOTES
• ALL WORK TO COMPLY WITH APPLICABLE PORTIONS OF THE
2018 INTERNATIONAL MECHANICAL CODE AND 2018
WASHINGTON STATE RESIDENTIAL ENERGY CODE, AS
AMENDED.
• SOURCE SPECIFIC FANS SHALL BE LOCATED IN ALL
KITCHENS, BATHROOMS, WATER CLOSETS AND LAUNDRY
FACILITIES.
1. VENTILATION CAPACITY SHALL BE AT LEAST 50
CFM FOR BATHROOMS AND LAUNDRY ROOMS
AND 100 CFM FOR KITCHENS. DUCTING SHALL
TERMINATE OUTSIDE THE BUILDING AND SHALL
BE EQUIPPED WITH BACKDRAFT DAMPERS.
• WHOLE HOUSE VENTILATION SYSTEM SHALL BE PROVIDED.
OUTDOOR AIR SHALL BE PROVIDED TO ALL HABITABLE
ROOMS.
• INTEGRATED WHOLE HOUSE VENTILATION THE 90 CFM TO BE
PROVIDED "CONTINUOUSLY".
MOISTURE PROTECTION
• PROVIDE PRESSURE TREATED PLATES BETWEEN CONCRETE
AND FRAMING.
• PROVIDE A MINIMUM OF 12" CLEAR BETWEEN WOOD
GIRDERS AND EARTH.
• PROVIDE A MINIMUM OF 18" CLEAR BETWEEN WOOD JOISTS
AND EARTH.
• PROVIDE A MINIMUM OF 8" CLEAR BETWEEN WOOD POSTS
AND EARTH.
• PROVIDE A MINIMUM OF 1" CLEAR BETWEEN WOOD POSTS
AND CONCRETE FLOORS.
• CAULK ALL OPENINGS THOROUGHLY.
• FLASH ALL OPENINGS WITH A MINIMUM OF 26 GAUGE
GALVANIZED STEEL TO ACCEPTABLE INDUSTRY STANDARDS.
• METAL COPING AT PARAPET TO BE A MINIMUM OF 22 GAUGE
GALVANIZED STEEL.
BATHROOM NOTES
WALL COVERING IN SHOWERS TO BE MOISTURE RESISTANT
MATERIAL TO 72" MINIMUM ABOVE DRAIN INLET.
TOILET TO HAVE CLEAR SPACE OF 30"WIDE MINIMUM AND 24"
CLEAR IN FRONT OF STOOL.
FIRE PROTECTION
• GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND
IT'S ATTIC BY THE FOLLOWING:
1. (1) LAYER OF 5/s" GYPSUM WALLBOARD APPLIED
TO ALL GARAGE WALLS.
2. (1) LAYER OF 5/s" TYPE "X" GYPSUM WALLBOARD
AT GARAGE CEILINGS.
• 1-3/s" MINIMUM THICK, SOLID CORE, OR HONEYCOMB CORE
STEEL DOOR, OR A 20-MIN. FIRE -RATED DOOR.
• DUCTS PIERCING FIRE SEPARATION TO BE A MINIMUM OF 26
GAUGE.
• FIRE SEPARATION TO BE HORIZONTAL AND VERTICAL
INCLUDING ALL STRUCTURAL MEMBERS SUPPORTING THE
FIRE SEPARATION.
• ALL ENCLOSED USABLE SPACE UNDER STAIRWAYS SHALL BE
(1) LAYER OF 5/s" TYPE "X" GYPSUM WALLBOARD ON
ENCLOSED SIDE.
• SMOKE DETECTORS SHALL BE HARD WIRED TO BUILDING
POWER AND SHALL HAVE BATTERY BACKUP.
• SMOKE DETECTORS SHALL BE AUDIBLE IN ALL SLEEPING
ROOMS, AND OUTSIDE EACH SLEEPING AREA IN THE
IMMEDIATE VICINITY OF THE BEDROOMS.
• A MINIMUM OF (1) SMOKE DETECTOR SHALL BE INSTALLED
ON EACH FLOOR INCLUDING THE GARAGE.
• FIRESTOPPING AND DRAFTSTOPPING SHALL CONSIST OF 2"
NOMINAL LUMBER.
• FIRESTOPPING AND DRAFTSTOPPING IS REQUIRED IN THE
FOLLOWING LOCATIONS:
1. CONCEALED SPACES AT ALL FLOOR AND CEILING
LEVELS AND AT 10 FOOT INTERVALS ALONG THE
LENGTH OF THE WALL.
2. INTERCONNECTIONS BETWEEN CONCEALED
VERTICAL AND HORIZONTAL SPACES.
3. CONCEALED SPACES BETWEEN STAIR
STRINGERS AT TOP AND BOTTOM OF THE RUN.
• ROCK WOOL AROUND ALL OPENINGS FOR VENTS, PIPES,
DUCTS, ETC.
• EMERGENCY EGRESS WINDOWS SHALL MEET THE
FOLLOWING REQUIREMENTS:
1. CLEAR OPEN WIDTH OF 20" MINIMUM
2. CLEAR OPEN HEIGHT OF 24" MINIMUM
3. CLEAR OPEN AREA OF 5.7 SF MINIMUM
4. SILL HEIGHT 44" MAXIMUM
• PREFABRICATED FIREPLACES SHALL BEAR U.L. OR I.C.B.O.
SEAL OF APPROVAL AND SHALL BE INSTALLED PER
MANUFACTURER INSTRUCTIONS.
• APPLIANCE GENERATING A GLOW, SPARK, OR FLAME MAY BE
INSTALLED IN THE GARAGE PROVIDED THE HEATING
ELEMENT AND SWITCHES ARE 18" ABOVE THE FLOOR.
• GARAGE FLOOR TO BE CONSTRUCTED OF NON
COMBUSTIBLE MATERIAL (CONCRETE).
SHOP DRAWINGS
• SHOP DRAWINGS ARE REVIEWED FOR DESIGN INTENT ONLY.
• CONTRACTOR IS TO REVIEW AND APPROVED ALL SHOP
DRAWINGS PRIOR TO SUBMITTING TO ARCHITECT OR
STRUCTURAL ENGINEER.
• SEE STRUCTURAL NOTES AND PROJECT SPECIFICATION FOR
ADDITIONAL REQUIREMENTS AND CLARIFICATIONS
REGARDING SHOP DRAWINGS.
SAFETY AND SECURITY
• DEADBOLTS WITH A MINIMUM THROW OF'/2" AND VIEWPORT
ARE REQUIRED AT ALL EXTERIOR DOORS.
• DEADBOLTS OR APPROVED LOCKING DEVICES ARE
REQUIRED ON ALL SLIDING DOORS.
• ALL LOCKS SHALL BE OPENABLE WITHOUT ANY SPECIAL
KNOWLEDGE OR EFFORT.
• WINDOWS WITHIN 10'-0" OF FINISHED GRADE SHALL BE
PROVIDED WITH LATCHING DEVICES.
• STAIRWAY TO MEET THE FOLLOWING REQUIREMENTS:
1. STAIR WIDTH OF 36" MINIMUM
2. TREAD WIDTH OF 10" MINIMUM, AND 6" MINIMUM
FOR WINDERS
3. RISER HEIGHT OF 7 3/a" MAXIMUM
4. HEADROOM OF 80" MINIMUM
5. HANDRAIL HEIGHT OF 34" TO 38" ABOVE NOSING
6. HANDRAIL GRASP OF 1-'/4" MINIMUM TO 2"
MAXIMUM
7. HANDRAIL INTERMEDIATE MEMBERS SHALL BE
CONFIGURED AS TO PROHIBIT A 4" DIAMETER
SPHERE THROUGH ANY OPENING.
8. GUARDRAILS SHALL BE A MINIMUM OF 36" ABOVE
FINISH FLOOR.
9. GUARDRAIL INTERMEDIATE MEMBERS SHALL BE
CONFIGURED AS TO PROHIBIT A 4" DIAMETER
SPHERE THROUGH ANY OPENING.
GLAZING NOTES
• ALL GLAZING TO BE (2) PANE INSULATED GLASS OR BETTER
EXTERIOR LIGHTING
INSULATION VALUES
UNLESS NOTED OTHERWISE.
• SLAB PERIMETER
R-10
SLIDING DOORS TO BE SAFETY GLASS, LAMINATED GLASS,
EXTERIOR LIGHTING SHALL BE SHIELDED AND DIRECTED AWAY
BELOW GRADE WALLS (INT)
R-21
OR TEMPERED GLASS.
FROM RESIDENTIALLY ZONED LOTS. ALL EXTERIOR LIGHTING WILL
BELOW GRADE WALLS (EXT)
R-10
SHOWER DOORS AND ENCLOSURES TO BE SAFETY GLASS,
BE SHIELDED AND DIRECTED AWAY FROM ABUTTING PROPERTIES.
ABOVE GRADE WALLS
R-21
LAMINATED GLASS, OR TEMPERED GLASS.
• FLOORS (OVER UNHEATED SPACE)
R-30
REFER TO WINDOW SCHEDULE FOR ADDITIONAL
• CEILINGS
R-49
REQUIREMENTS.
GRADING MUST BE STABILIZED BY OCTOBER 31ST. NO
VAULTED CEILINGS
R-38
EXCAVATION OR FILL PLACEMENT CAN BE PERFORMED BETWEEN
WINDOW/DOOR HEADERS
R-10
TABLE R402.1.1
OCTOBER 31ST AND APRIL 1ST.
BETWEEN CONDITIONED SPACES
R-21
ROOF INSULATION
• BETWEEN CONDITIONED SPACE AND
R-30
MINIMUM R-38 INSULATION IS REQUIRED AT VAULTED
CEILING/GARAGE
GEOMETRIES, OTHERWISE, R-49 IS REQUIRED.
• FLOOR INSULATION
• MINIMUM R-30 INSULATION AT FRAMED, RAISED, FLOOR
ASSEMBLIES.
• SLAB -ON -GRADE INSULATION
• MINIMUM R-10 INSULATION UNDER THE SLABS.
INSULATION CERTIFICATE
A PERMANENT CERTIFICATE SHALL BE COMPLETED BY THE BUILDER OR REGISTERED DESIGN PROFESSIONAL AND POSTED ON A WALL IN THE SPACE WHERE THE FURNACE IS LOCATED, A UTILITY ROOM OR AN
APPROVED LOCATION INSIDE THE BUILDING. WHERE LOCATED ON AN ELECTRICAL PANEL, THE CERTIFICATE SHALL NOT COVER OR OBSTRUCT THE VISIBILITY OF THE CIRCUIT DIRECTORY LABEL, SERVICE DISCONNECT
LABEL OR OTHER REQUIRED LABELS. THE CERTIFICATE SHALL LIST THE PREDOMINANT R-VALUES OF INSULATION INSTALLED IN OR ON CEILING/ROOF, WALLS, FOUNDATION (SLAB, BASEMENT WALL, CRAWL SPACE
WALL AND/OR FLOOR) AND DUCTS OUTSIDE CONDITIONED SPACES; U-FACTORS FOR FENESTRATION AND THE SOLAR HEAT GAIN COEFFICIENT (SHGC) OF FENESTRATION, AND THE RESULTS FROM ANY REQUIRED DUCT
SYSTEM AND BUILDING ENVELOPE AIR LEAKAGE TESTING DONE ON THE BUILDING. WHERE THERE IS MORE THAN ONE VALUE FOR EACH COMPONENT, THE CERTIFICATE SHALL LIST THE VALUE COVERING THE LARGEST
AREA. THE CERTIFICATE SHALL LIST THE TYPES AND EFFICIENCIES OF HEATING, COOLING AND SERVICE WATER HEATING EQUIPMENT. WHERE ACAS -FIRED UNVENTED ROOM HEATER, ELECTRIC FURNACE, OR
BASEBOARD ELECTRIC HEATER IS INSTALLED IN THE RESIDENCE, THE CERTIFICATE SHALL LIST "GAS -FIRED UNVENTED ROOM HEATER," "ELECTRIC FURNACE" OR "BASEBOARD ELECTRIC HEATER," AS APPROPRIATE.
AN EFFICIENCY SHALL NOT BE LISTED FOR GAS -FIRED UNVENTED ROOM HEATERS, ELECTRIC FURNACES OR ELECTRIC BASEBOARD HEATERS.
GENERAL NOTES -CONTRACTOR
• ALL WORK TO COMPLY WITH 2O18 INTERNATIONAL RESIDENTIAL CODE AND INTERNATIONAL BUILDING CODE WITH
AMENDMENTS WHERE APPLICABLE.
• ALL APPLICABLE CODES, ORDINANCES, AND MINIMUM STRUCTURAL REQUIREMENTS TAKE PRECEDENCE OVER ALL
DRAWINGS, NOTES, AND SPECIFICATIONS.
• DO NOT SCALE DRAWINGS; ALWAYS USE PRINTED DIMENSIONS ONLY. ALWAYS NOTIFY ARCHITECT OF ANY OMISSIONS OR
DISCREPANCIES BEFORE PROCEEDING WITH WORK IN QUESTION.
• CONTRACTOR MUST CONTACT ARCHITECT IMMEDIATELY FOR ANY DISCREPANCIES IN CONTRACT DOCUMENTS OR EXISTING
CONDITIONS PRIOR TO PROCEEDING WITH WORK.
• CONTRACTOR MUST CONTACT ARCHITECT IMMEDIATELY FOR ANY DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND
APPLICABLE CODES PRIOR TO PROCEEDING WITH WORK.
• CONTRACTOR TO VERIFY ALL DIMENSIONS, GRADES, AND EXISTING CONDITIONS BEFORE PROCEEDING WITH WORK.
• CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF/HERSELF WITH ALL ASPECTS OF THE WORK PRIOR TO
CONTRACTING WITH THE OWNER TO PERFORM THE WORK.
• CONTRACTOR SHALL VERIFY CONFORMANCE OF ACTUAL SOIL CONDITIONS WITH SOILS REPORT AND DESIGN
ASSUMPTIONS.
• CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING ALL NECESSARY PERMITS FOR THE WORK, EXCEPT FOR THE
BUILDING PERMIT WHICH IS THE RESPONSIBILITY OF THE ARCHITECT.
• GUARANTEE ON ALL MATERIALS AND WORKMANSHIP TO BE (1) YEAR FROM DATE OF COMPLETION UNLESS NOTED
OTHERWISE IN THE CONTRACT.
• REPETITIVE FEATURES MAY BE DRAWN ONLY ONCE, BUT SHALL BE PROVIDED IN FULL. REPETITIVE NOTES MAY BE CALLED
OUT ONLY ONCE AND INDICATE AS TYPICAL.
• DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE OR CENTERLINE OF INTERIOR COLUMNS UNLESS NOTED
OTHERWISE.
• CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL MECHANICAL, ELECTRICAL, AND PLUMBING CONTRACTORS AND
NOTIFYING THE ARCHITECT OF ANY DISCREPANCIES IN FRAMING PRIOR TO PROCEEDING WITH WORK.
• ALL MECHANICAL, ELECTRICAL, &PLUMBING IS TO BE DESIGN -BUILD.
FOR PERMIT
ONLY
THIS DOCUMENT HAS BEEN
PREPARED FOR PERMIT
APPLICATION AND IS SUBJECT TO
REVIEW AND MODIFICATION BY
GOVERNMENTAL AGENCIES
11 /22/2021
ALL DRAWINGS, SPECIFICATIONS, PLANS, AND
DESIGNS REPRESENTED OR REFERRED TO ARE
THE PROPERTY OF AND OWNED BY COASTAL
CIRCLE, LLC. WHETHER THE PROJECT FOR WHICH
THEY ARE MADE IS EXECUTED OR NOT, THEY WERE
CREATED, DEVELOPED, AND PRODUCED FOR THE
SOLE USE ON AND IN CONNECTION WITH THIS
PROJECT AND NONE OF THE ABOVE MAYBE
DISCLOSED OR GIVEN TO OR USED BY ANY
PERSON, FIRM, OR CORPORATION FOR ANY USE OR
PURPOSE WHATSOEVER INCLUDING ANY OTHER
PROJECT, EXCEPT UPON WRITTEN PERMISSION OF
COASTAL CIRCLE, LLC.
COASTAL CIRCLE
• � �
INFO@COASTALCIRCLE.COM
a
v�
c
z
O
W
N
J
a
r
M
N
N
M
Ln
RESUB
Dec 07 20�'I �
CITY OF EDMONDS E D
DEVELOPMENT SERVICES
� DEPARTMENT
APPROVAL
STAMP S PAC E
GENERAL
NOTES
9532 231 ST PL SW,
EDMONDS, WA
PERMIT SET
PERMIT #
DATE 11 /22/2021
A-
Scale
30'-0"
30' - 0"
GENERAL NOTES
FIRE RATING:
• SOLID WOOD DOORS NOT LESS
THAN 1-3/8 INCHES IN THICKNESS,
SOLID OR HONEYCOMB -CORE
STEEL DOORS NOT LESS THAN
1-3/8 INCHES THICK, OR 20-
MINUTE FIRE -RATED DOORS,
EQUIPPED WITH A SELFCLOSING
DEVICE.
• 1 HOUR FIRE RESISTANCE RATED
WALL. TESTED IN ACCORDANCE
WITH ASTM E 119/UL 263. MIN 1
LAYER 5/8" TYPE X GWB ON
GARAGE CEILING. MIN 1 LAYER
1/2" GWB ON ALL GARAGE WALLS
SEPARATING GARAGE FROM
LIVING SPACE.
INSULATION:
• MIN. R-21 INSULATION BETWEEN
THE HEATED SPACE AND LOW -
ENERGY, OR UNHEATED SPACE.
MIN. R-21 INSULATION FOR ALL
WALLS/FLOORS SEPARATING
GARAGE FROM CONDITIONED
SPACE.
• UNHEATED GARAGE. INSULATE
CEILING UNDER HEATED SPACE
ABOVE (R30 MINIMUM GARAGE
CEILING &MIN 1 LAYER 5/8" TYPE
X GWB.
INSULATION VALUES:
• SLAB PERIMETER R-10
• WINDOW/DOOR HEADERS R-10
• BELOW GRADE WALLS (EXT) R-10
• BELOW GRADE WALLS (INT) R-21
• ABOVE GRADE WALLS R-21
• BETWEEN HEAT/UNHEATED R-21
• OVER UNHEATED GARAGE R-30
• FLOOR R-30
• VAULTED CEILINGS R-38
• CEILINGS R-49
MECHANICAL/VENTILATION:
• SOURCE SPECIFIC FANS SHALL
BE LOCATED IN ALL KITCHENS,
BATHROOMS, WATER CLOSETS
AND LAUNDRY FACILITIES
• CAPACITY SHALL BE AT LEAST 50
CFM FOR BATHROOMS AND
LAUNDRY ROOMS AND 100 CFM
FOR KITCHENS. DUCTING SHALL
TERMINATE OUTSIDE THE
BUILDING AND SHALL BE
EQUIPPED WITH BACKDRAFT
DAMPERS.
• WHOLE HOUSE VENTILATION
SYSTEM SHALL BE PROVIDED.
OUTDOOR AIR SHALL BE
PROVIDED TO ALL HABITABLE
ROOMS.
• INTEGRATED WHOLE HOUSE
VENTILATION THE 90 CFM TO BE
PROVIDED "CONTINUOUSLY".
• MAKEUP AIR IS REQUIRED FOR
ANY KITCHEN FAN EXCEEDING
400CFM. KITCHEN FANS ARE TO
RUN AT 25 CFM CONTINUOUSLY
OR BE A MIN OF 100 CFM IF
SWITCHED INTERMITTENTLY.
• BATH EXHAUST FANS VENT. MIN
20 CFM CONTINUOUSLY OR BE
SET AT 50 CFM IF RUN/SWITCHED
INTERMITTENTLY.
• KITCHEN FANS ARE TO RUN AT 25
CFM CONTINUOUSLY OR BE A MIN
OF 100 CFM IF SWITCHED
INTERMITTENTLY. PER SRC 1503.4,
MAKEUP AIR IS REQUIRED FOR
ANY KITCHEN FAN EXCEEDING
400CFM.
• GAS FIRED H2O HEATER - EF .82.
• GAS FIREPLACE W/ MANUF.
REQUIRED VENTING -PROVIDE
COMBUSTIBLE MAT. CLEARANCES
• TO BE UL LISTED REF
R1004.1 SRC
• FACTORY BUILT FIREPLACE
TO BE LISTED,
• LABELED AND INSTALLED
WITH THE CONDITIONS OF
THE LISTING. FACTORY
BUILT
• FIREPLACE MUST BE
TESTED IN ACCORDANCE
WITH UL 127.
• ALL EXHAUSTS SHALL TERMINATE
OUTSIDE NOT LESS THAN:
• 3 FEET FROM PROPERTY
LINES;
• 3 FEET FROM
OPERABLE/NONOPERABLE
OPENINGS INTO BUILDINGS
AND
• 10 FEET FROM MECHANICAL
AIR INTAKES,
• EXCEPT WHERE OPENING IS
3 FEET ABOVE AIR
INTAKES," PER SRC M1506.3.
• GAS FIREPLACE TO BE
DIRECT VENT -MANUF.
d
ATTIC ACCESS ABOVE
Level 2
I-
� Level1
r:�a��
LEVEL 2 EXISTING
40' - 0"
29' - 0"
LEVEL 1 EXISTING
STAIRS TO REMAIN
II � o
0
EXISTING LIGHTING FOR STAIRS TO REMAIN
NEW HOOD VENT TO
BE CONNECTED TO
EXISTING HOOD VENT
EXHAUST
NEW BATH FAN TO
BE CONNECTED TO
EXISTING BATH FAN
EXHAUST
LOFT ABOVE
CRAWL SPACE ACCESS THROUGH
_ FOUNDATION WALL ON EXTERIOR
0
0
N
ATTIC ACCESS ABOVE
r:�a��
�5'-6" 2'-6"
LEVEL 2 PROPOSED
� — — — — — —
II
-1' - 0"
FAMILY ROOM I �
189 SF � I I, w, � ��
14'-0" �o I � �I N \ i
�o,-o„ I � o'-o° o
3'Qx6'
N-102 �
WOOD FRAMING I
OVER CRAWL SPACE I ��
'ox6'
N-103 I
NEW REF, SINK, &DW o' o" I
B�H "
NEW GAS RANGE O
43 S FN
� � - ®� I
r
KITCHEN �� I \ �' - o°
251 SF o' = o°
II II II II II I I
4'-0" _ I I 1 �T II II I II I I
2, L " I I� II
4, - O„ -103 IF II I II II I
I _ II II I I
3' - 4 1 /4" I I I I I I I I
- tt— _ _— —_ _�_- -
LL
-2� 6 = —� ������� �\
�`�
WOOD FRAMING
OVER CRAWL SPACE
DINING ROOM
�o' - o° 126 S F
9' - 10"
GARAGE BELOW &
SLOPED ROOF
NEW BATH FAN TO
BE CONNECTED TO
EXISTING BATH
FAN EXHAUST
NEW VANITY &TOILET
NEW BATH FAN
NEW SHOWER &TUB
1 HOUR FIRE RESISTANCE
RATED WALL. TESTED IN
ACCORDANCE WITH ASTM
E 119/UL 263. MIN 1 LAYER
5/8" TYPE X GWB ON
GARAGE CEILING. MIN 1
LAYER 1/2" GWB ON ALL
GARAGE WALLS
SEPARATING GARAGE
FROM LIVING SPACE.
EXISTING LIGHTING FOR STAIRS TO REMAIN
SOLID WOOD DOORS NOT LESS THAN
1-3/8 INCHES IN THICKNESS, SOLID OR
HONEYCOMB -CORE STEEL DOORS NOT
LESS THAN 1-3/8 INCHES THICK, OR 20-
MINUTE FIRE -RATED DOORS, EQUIPPED
WITH A SELFCLOSING DEVICE. -- -- -
GARAGE
1'-0"
389 SF �}
CONCRETE.
SLAB -ON -GRADE
NEW VANITY &TOILET
18'-0"
�I I
ti I I I
, _
M I I I
�II� I I I
��V - o„
II WOOD FRAMING
�, _ o„ OVER CRAWL SPACE
LIVING ROOM 'I
236 S F II
18'-2"
29' - 0"
LEVEL 1 PROPOSED
LOCATION
OF WORK
0
1 HOUR FIRE
RESISTANCE RATED
WALL. TESTED IN
ACCORDANCE WITH
ASTM E 119/UL 263.
MIN 1 LAYER 5/8" TYPE
X GWB ON GARAGE
CEILING. MIN 1 LAYER
1/2" GWB ON ALL
GARAGE WALLS
SEPARATING GARAGE
FROM LIVING SPACE.
NEW CONDITIONED SPACE TO MEET THE 2018
WSEC REQUIREMENTS.
EXISTING LIGHTING FOR STAIRS TO REMAIN
OVERFRAME
FLOOR TO MATCH
ELEVATION OF
EXISTING FLOORS
LOFT ABOVE
LOCATION
OF WORK
PLAN LEGEND
1-HR RATED WALL &INSULATION (MIN. R-21)
ATTIC ACCESS (22"x30")
• BATH I LAUNDRY FAN - 50cfm MIN.
�O CO DETECTOR
- - FAN DUCT &EXHAUST
• KITCHEN FAN-100cfm MIN.
® SMOKE DETECTOR -HARDWIRED &INTERCONNECTED
(T) TEMPERED GLASS
T THERMOSTAT
FOR PERMIT
ONLY
THIS DOCUMENT HAS BEEN
PREPARED FOR PERMIT
APPLICATION AND IS SUBJECT TO
REVIEW AND MODIFICATION BY
GOVERNMENTAL AGENCIES
11 /22/2021
ALL DRAWINGS, SPECIFICATIONS, PLANS, AND
DESIGNS REPRESENTED OR REFERRED TO ARE
THE PROPERTY OF AND OWNED BY COASTAL
CIRCLE, LLC. WHETHER THE PROJECT FOR WHICH
THEY ARE MADE IS EXECUTED OR NOT, THEY WERE
CREATED, DEVELOPED, AND PRODUCED FOR THE
SOLE USE ON AND IN CONNECTION WITH THIS
PROJECT AND NONE OF THE ABOVE MAYBE
DISCLOSED OR GIVEN TO OR USED BY ANY
PERSON, FIRM, OR CORPORATION FOR ANY USE OR
PURPOSE WHATSOEVER INCLUDING ANY OTHER
PROJECT, EXCEPT UPON WRITTEN PERMISSION OF
COASTAL CIRCLE, LLC.
COASTAL CIRCLE
• � �
INFO@COASTALCIRCLE.COM
Z
O
W
J
a
r
M
N
N
M
Ln
RESUB
Dec o7 2o�TED
CITY OF EDMONDS
DEVELOPMENT SERVICES�AL
DEPARTMENT-
STAM P S PAC E
LEVEL 1 &
LEVEL 2
9532 231 ST PL SW,
EDMONDS, WA
PERMIT SET
PERMIT #
DATE 11 /22/2021
A—
Scale 1 /4" = 1'-0"
GENERAL NOTES
FIRE RATING:
• SOLID WOOD DOORS NOT LESS
THAN 1-3/8 INCHES IN THICKNESS,
SOLID OR HONEYCOMB -CORE
STEEL DOORS NOT LESS THAN
1-3/8 INCHES THICK, OR 20-
MINUTE FIRE -RATED DOORS,
EQUIPPED WITH A SELFCLOSING
DEVICE.
• 1 HOUR FIRE RESISTANCE RATED
WALL. TESTED IN ACCORDANCE
WITH ASTM E 119/UL 263. MIN 1
LAYER 5/8" TYPE X GWB ON
GARAGE CEILING. MIN 1 LAYER
1/2" GWB ON ALL GARAGE WALLS
SEPARATING GARAGE FROM
LIVING SPACE.
INSULATION:
• MIN. R-21 INSULATION BETWEEN
THE HEATED SPACE AND LOW -
ENERGY, OR UNHEATED SPACE.
MIN. R-21 INSULATION FOR ALL
WALLS/FLOORS SEPARATING
GARAGE FROM CONDITIONED
SPACE.
• UNHEATED GARAGE. INSULATE
CEILING UNDER HEATED SPACE
ABOVE (R30 MINIMUM GARAGE
CEILING &MIN 1 LAYER 5/8" TYPE
X GWB.
• SLAB PERIMETER
R-10
• WINDOW/DOOR HEADERS
R-10
• BELOW GRADE WALLS (EXT)
R-10
• BELOW GRADE WALLS (INT)
R-21
• ABOVE GRADE WALLS
R-21
• BETWEEN HEAT/UNHEATED
R-21
• OVER UNHEATED GARAGE
R-30
• FLOOR
R-30
• VAULTED CEILINGS
R-38
• CEILINGS
R-49
MECHANICAL/VENTILATION:
• SOURCE SPECIFIC FANS SHALL
BE LOCATED IN ALL KITCHENS,
BATHROOMS, WATER CLOSETS
AND LAUNDRY FACILITIES
• CAPACITY SHALL BE AT LEAST 50
CFM FOR BATHROOMS AND
LAUNDRY ROOMS AND 100 CFM
FOR KITCHENS. DUCTING SHALL
TERMINATE OUTSIDE THE
BUILDING AND SHALL BE
EQUIPPED WITH BACKDRAFT
DAMPERS.
• WHOLE HOUSE VENTILATION
SYSTEM SHALL BE PROVIDED.
OUTDOOR AIR SHALL BE
PROVIDED TO ALL HABITABLE
ROOMS.
• INTEGRATED WHOLE HOUSE
VENTILATION THE 90 CFM TO BE
PROVIDED "CONTINUOUSLY".
• MAKEUP AIR IS REQUIRED FOR
ANY KITCHEN FAN EXCEEDING
400CFM. KITCHEN FANS ARE TO
RUN AT 25 CFM CONTINUOUSLY
OR BE A MIN OF 100 CFM IF
SWITCHED INTERMITTENTLY.
• BATH EXHAUST FANS VENT. MIN
20 CFM CONTINUOUSLY OR BE
SET AT 50 CFM IF RUN/SWITCHED
INTERMITTENTLY.
• KITCHEN FANS ARE TO RUN AT 25
CFM CONTINUOUSLY OR BE A MIN
OF 100 CFM IF SWITCHED
INTERMITTENTLY. PER SRC 1503.4,
MAKEUP AIR IS REQUIRED FOR
ANY KITCHEN FAN EXCEEDING
400CFM.
• GAS FIRED H2O HEATER - EF .82.
• GAS FIREPLACE W/ MANUF.
REQUIRED VENTING -PROVIDE
COMBUSTIBLE MAT. CLEARANCES
• TO BE UL LISTED REF
R1004.1 SRC
• FACTORY BUILT FIREPLACE
TO BE LISTED,
• LABELED AND INSTALLED
WITH THE CONDITIONS OF
THE LISTING. FACTORY
BUILT
• FIREPLACE MUST BE
TESTED IN ACCORDANCE
WITH UL 127.
• ALL EXHAUSTS SHALL TERMINATE
OUTSIDE NOT LESS THAN:
• 3 FEET FROM PROPERTY
LINES;
• 3 FEET FROM
OPERABLE/NONOPERABLE
OPENINGS INTO BUILDINGS
AND
• 10 FEET FROM MECHANICAL
AIR INTAKES,
• EXCEPT WHERE OPENING IS
3 FEET ABOVE AIR
INTAKES," PER SRC M1506.3.
• GAS FIREPLACE TO BE
DIRECT VENT -MANUF.
i
M
FAMILY ROOM
193 SF
o ifl 14' - 0"
I�
WOOD FRAMING
OVER CRAWL SPACE
�,,
\ N
\\\ -
o a \ KITCHEN
124 S F
0
� 10' - 4" � w
� �
3'-2"
WORK TO BE PERFORMED
IN THE HATCHED AREA
40' - 0"
EXISTING GAS FURNACE ON PEDESTAL - 90
CFM WHOLE HOUSE VENTILATION SYSTEM.
M1507.3.5 INTEGRATED WITH AFORCED-AIR
� SYSTEM FRESH AIR - M1507.3.5.3 USING
INTEGRATED WITH FORCED AIR SYSTEM
��' wH `� EXISTING HOT WATER HEATER
\ GARAGE
\ 445 SF �1' - o°
I \\
�� 1' - o° CONCRETE,
SLAB -ON -GRADE
I�
SF ��
O
I I 114 R @ 10' - 6 13/32"
I I _ �� I
I I �
M �
I I I
1' - 0" 9' - 4" -uN--
N I ------- _1' 0" --
� � I
WOOD FRAMING ' � WOOD FRAMING
OVER CRAWL SPACE i � OVER CRAWL SPACE
��
s DINING ROOM � 8'oX s V `� LIVING ROOM
0'-0" � _ 1�_0��
119 SF \ � 347 SF
iv � 0'-0" -1'-0"
�O � � � Y I
---
n LEVEL 1
�- 1 /4" = 1'-0"
29' - 0"
LEVEL 1 EXISTING
��6'8 ��
....E-X101
X
EXISTING LIGHTING FOR STAIRS TO REMAIN
NEW HOOD VENT TO
BE CONNECTED TO
EXISTING HOOD VENT
EXHAUST
NEW BATH FAN TO
BE CONNECTED TO
EXISTING BATH FAN
EXHAUST
LOFT ABOVE
CRAWL SPACE ACCESS THROUGH
- ___ FOUNDATION WALL ON EXTERIOR
�/�
LEVEL 1 EXISTING
29'-0"
LEVEL 1 PROPOSED
LEVEL 1 PROPOSED
LEGEND
GARAGE
HEATED
_�
1 HOUR FIRE
RESISTANCE RATED
WALL. TESTED IN
ACCORDANCE WITH
ASTM E 119/UL 263.
MIN 1 LAYER 5/8" TYPE
X GWB ON GARAGE
CEILING. MIN 1 LAYER
1/2" GWB ON ALL
GARAGE WALLS
SEPARATING GARAGE
FROM LIVING SPACE.
EXISTING LIGHTING FOR STAIRS TO REMAIN
OVERFRAME
FLOOR TO MATCH
ELEVATION OF
EXISTING FLOORS
LOFT ABOVE
LOCATION
OF WORK
PLAN LEGEND
1-HR RATED WALL &INSULATION (MIN. R-21)
�A ATTIC ACCESS (22"x30")
• BATH I LAUNDRY FAN - 50cfm MIN.
CO CO DETECTOR
- - FAN DUCT &EXHAUST
• KITCHEN FAN-100cfm MIN.
® SMOKE DETECTOR -HARDWIRED &INTERCONNECTED
(T) TEMPERED GLASS
T THERMOSTAT
FOR PERMIT
ONLY
THIS DOCUMENT HAS BEEN
PREPARED FOR PERMIT
APPLICATION AND IS SUBJECT TO
REVIEW AND MODIFICATION BY
GOVERNMENTAL AGENCIES
11 /22/2021
ALL DRAWINGS, SPECIFICATIONS, PLANS, AND
DESIGNS REPRESENTED OR REFERRED TO ARE
THE PROPERTY OF AND OWNED BY COASTAL
CIRCLE, LLC. WHETHER THE PROJECT FOR WHICH
THEY ARE MADE IS EXECUTED OR NOT, THEY WERE
CREATED, DEVELOPED, AND PRODUCED FOR THE
SOLE USE ON AND IN CONNECTION WITH THIS
PROJECT AND NONE OF THE ABOVE MAYBE
DISCLOSED OR GIVEN TO OR USED BY ANY
PERSON, FIRM, OR CORPORATION FOR ANY USE OR
PURPOSE WHATSOEVER INCLUDING ANY OTHER
PROJECT, EXCEPT UPON WRITTEN PERMISSION OF
COASTAL CIRCLE, LLC.
COASTAL CIRCLE
• � �
INFO@COASTALCIRCLE.COM
Z
O
J
M
N
N
M
Ln
RESUB
Dec o7 2o�TED
CITY OF EDMONDS
DEVELOPMENT SERVICES�AL
DEPARTMENT- �
STAMP S PAC E
LEVEL 1
9532 231 ST PL SW,
EDMONDS, WA
PERMIT SET
PERMIT #
DATE 11 /22/2021
A-
Scale As indicated
GENERAL NOTES
FOR PERMIT
FIRE RATING:
• SOLID WOOD DOORS NOT LESS
THAN 1-3/8 INCHES IN THICKNESS,
SOLID OR HONEYCOMB -CORE
STEEL DOORS NOT LESS THAN
1-3/8 INCHES THICK, OR 20-
MINUTE FIRE -RATED DOORS,
EQUIPPED WITH A SELFCLOSING
DEVICE.
• 1 HOUR FIRE RESISTANCE RATED
WALL. TESTED IN ACCORDANCE
WITH ASTM E 119/UL 263. MIN 1
LAYER 5/8" TYPE X GWB ON
GARAGE CEILING. MIN 1 LAYER
1/2" GWB ON ALL GARAGE WALLS
SEPARATING GARAGE FROM
LIVING SPACE.
INSULATION:
• MIN. R-21 INSULATION BETWEEN
THE HEATED SPACE AND LOW -
ENERGY, OR UNHEATED SPACE.
MIN. R-21 INSULATION FOR ALL
WALLS/FLOORS SEPARATING
GARAGE FROM CONDITIONED
SPACE.
• UNHEATED GARAGE. INSULATE
CEILING UNDER HEATED SPACE
ABOVE (R30 MINIMUM GARAGE
CEILING &MIN 1 LAYER 5/8" TYPE
X GWB.
• SLAB PERIMETER
R-10
• WINDOW/DOOR HEADERS
R-10
• BELOW GRADE WALLS (EXT)
R-10
• BELOW GRADE WALLS (INT)
R-21
• ABOVE GRADE WALLS
R-21
• BETWEEN HEAT/UNHEATED
R-21
• OVER UNHEATED GARAGE
R-30
• FLOOR
R-30
• VAULTED CEILINGS
R-38
• CEILINGS
R-49
MECHANICAL/VENTILATION:
• SOURCE SPECIFIC FANS SHALL
BE LOCATED IN ALL KITCHENS,
BATHROOMS, WATER CLOSETS
AND LAUNDRY FACILITIES
• CAPACITY SHALL BE AT LEAST 50
CFM FOR BATHROOMS AND
LAUNDRY ROOMS AND 100 CFM
FOR KITCHENS. DUCTING SHALL
TERMINATE OUTSIDE THE
BUILDING AND SHALL BE
EQUIPPED WITH BACKDRAFT
DAMPERS.
• WHOLE HOUSE VENTILATION
SYSTEM SHALL BE PROVIDED.
OUTDOOR AIR SHALL BE
PROVIDED TO ALL HABITABLE
ROOMS.
• INTEGRATED WHOLE HOUSE
VENTILATION THE 90 CFM TO BE
PROVIDED "CONTINUOUSLY".
• MAKEUP AIR IS REQUIRED FOR
ANY KITCHEN FAN EXCEEDING
400CFM. KITCHEN FANS ARE TO
RUN AT 25 CFM CONTINUOUSLY
OR BE A MIN OF 100 CFM IF
SWITCHED INTERMITTENTLY.
• BATH EXHAUST FANS VENT. MIN
20 CFM CONTINUOUSLY OR BE
SET AT 50 CFM IF RUN/SWITCHED
INTERMITTENTLY.
• KITCHEN FANS ARE TO RUN AT 25
CFM CONTINUOUSLY OR BE A MIN
OF 100 CFM IF SWITCHED
INTERMITTENTLY. PER SRC 1503.4,
MAKEUP AIR IS REQUIRED FOR
ANY KITCHEN FAN EXCEEDING
400CFM.
• GAS FIRED H2O HEATER - EF .82.
• GAS FIREPLACE W/ MANUF.
REQUIRED VENTING -PROVIDE
COMBUSTIBLE MAT. CLEARANCES
• TO BE UL LISTED REF
R1004.1 SRC
• FACTORY BUILT FIREPLACE
TO BE LISTED,
• LABELED AND INSTALLED
WITH THE CONDITIONS OF
THE LISTING. FACTORY
BUILT
• FIREPLACE MUST BE
TESTED IN ACCORDANCE
WITH UL 127.
• ALL EXHAUSTS SHALL TERMINATE
OUTSIDE NOT LESS THAN:
• 3 FEET FROM PROPERTY
LINES;
• 3 FEET FROM
OPERABLE/NONOPERABLE
OPENINGS INTO BUILDINGS
AND
• 10 FEET FROM MECHANICAL
AIR INTAKES,
• EXCEPT WHERE OPENING IS
3 FEET ABOVE AIR
INTAKES," PER SRC M1506.3.
• GAS FIREPLACE TO BE
DIRECT VENT -MANUF.
hl IIV/'1lrVLJJ„UIJVL L�V�L � �X15 I INCH
n LEVEL 2
��- 1 /4" = 1'-0"
Level 2
WORK TO BE PERFORMED
IN THE HATCHED
:LOW &
IOF
GHTING FOR STAIRS TO REMAIN
GARAGE
BELOW
LEVEL 2 EXISTING
0
0
u
„I Illy /'1VlrLJJ /"�UVVL L`V `L L hI�U hUV`U
GARAGE
BELOW
LEVEL 2 PROPOSED
LEGEND
HEATED
OPEN TO BELOW
NEW BATH FAN TO
BE CONNECTED TO
EXISTING BATH
FAN EXHAUST
NEW VANITY &TOILET
NEW BATH FAN
NEW SHOWER &TUB
1 HOUR FIRE RESISTANCE
RATED WALL. TESTED IN
ACCORDANCE W ITH ASTM
E 119/UL 263. MIN 1 LAYER
5/8" TYPE X GWB ON
GARAGE CEILING. MIN 1
LAYER 1/2" GWB ON ALL
GARAGE WALLS
SEPARATING GARAGE
FROM LIVING SPACE.
STAIRS TO REMAIN
LOCATION
OF WORK
PLAN LEGEND
1-HR RATED WALL &INSULATION (MIN. R-21)
�A ATTIC ACCESS (22"x30")
• BATH I LAUNDRY FAN - 50cfm MIN.
CO CO DETECTOR
- - FAN DUCT &EXHAUST
• KITCHEN FAN-100cfm MIN.
® SMOKE DETECTOR -HARDWIRED &INTERCONNECTED
(T) TEMPERED GLASS
T THERMOSTAT
ONLY
THIS DOCUMENT HAS BEEN
PREPARED FOR PERMIT
APPLICATION AND IS SUBJECT TO
REVIEW AND MODIFICATION BY
GOVERNMENTAL AGENCIES
11 /22/2021
ALL DRAWINGS, SPECIFICATIONS, PLANS, AND
DESIGNS REPRESENTED OR REFERRED TO ARE
THE PROPERTY OF AND OWNED BY COASTAL
CIRCLE, LLC. WHETHER THE PROJECT FOR WHICH
THEY ARE MADE IS EXECUTED OR NOT, THEY WERE
CREATED, DEVELOPED, AND PRODUCED FOR THE
SOLE USE ON AND IN CONNECTION WITH THIS
PROJECT AND NONE OF THE ABOVE MAYBE
DISCLOSED OR GIVEN TO OR USED BY ANY
PERSON, FIRM, OR CORPORATION FOR ANY USE OR
PURPOSE WHATSOEVER INCLUDING ANY OTHER
PROJECT, EXCEPT UPON WRITTEN PERMISSION OF
COASTAL CIRCLE, LLC.
COASTAL CIRCLE
• � �
INFO@COASTALCIRCLE.COM
Q
vi
0
z
O
W
N
J
a
r
M
N
N
M
Ln
RESUB
Dec o7 2o�TED
CITY OF EDMONDS
DEVELOPMENT SERVICES�AL
DEPARTMENT- �
STAMP S PAC E
LEVEL 2
9532 231 ST PL SW,
EDMONDS, WA
PERMIT SET
PERMIT #
DATE 11 /22/2021
A-
Scale As indicated
BYKONEN
CARTER
QUINN
STRUCTURAL
ENGINEERING
RECEIVED
Nov 02 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
STRUCTURAL
CALCULATIONS
McKinley Residence
9532 231 st PI. SW
Edmonds, WA 98020
Peak General Contracting
2212 Queen Anne Ave N #337
Seattle, WA 98109
October 18, 2021
► 2033 Sixth Avenue #995 Seattle, WA 98121 206-264-7784 www.BCQ-SE.com
_..._. ___...........
l+� � ��� t,�.-Y ���r��� c�
VL�M0a1.4--c c�� S� U�rt..�Z tg r,a-rLt^� (9 w,�-�t�5
fin/ �-sTc�2� �r�l(ab� - t=.d�M��� G
— NC% Cif 4/►�b �- '� EXl �7� G 1.�'t�✓✓1A-L 57 5 i tM
�v�-�%S
J, = yc� �?
CORN
QUINN
STRUCTURAL
EN6INEERIN6
RECEIVED
Nov 02 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
► 2033 Sixth Avenue #995 Seattle, WA 98121 206-264-7784 www.BCO-SE.com
(v' �G �NL � � ✓L Yfllr....._..................... DATE:.....__....._.. ...k�__........_.
PROJECT:............._............................._............_.................E✓YJII �._�g
DESIGNER:..... -__......�_......._...._.....__.._....._....._..._......_................. SHEET #:............._._...__---..........._..............
(E) FLOOR FRAMING
LEVEL 2 FRAMING PLAN
HHUS7.25110
HANGER
i
u
0
u
i
u
0
u
WOOD FRAMING PLAN NOTES
1. CONTRACTOR TO VERIFY EXISTING FRAMING AND NOTIFY ENGINEER OF ANY
DISCREPANCIES.
2. ALL COLUMNS SHALL BE DOUBLE STUDS MINIMUM, U.N.O., WITH BEAM OR HEADER
BEARING FULLY ON COLUMN.
FRAMING PLAN LEGEND
� WALLS BELOW
� � WALLS ABOVE
�' COLUMNS BELOW
°� COLUMNS ABOVE
n , n HANGER
FB INDICATES FLUSH BEAM
X INDICATES DETAIL X ON SHEET SX.XX
SX.XX
SPAN AND EXTENTS
RECEIVED
Nov 02 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
FOR PERMIT
ONLY
THIS DOCUMENT HAS BEEN
PREPARED FOR PERMIT
APPLICATION AND IS SUBJECT TO
REVIEW AND MODIFICATION BY
GOVERNMENTAL AGENCIES
BYKONEN
CARTER
QUINN
- S1RUCIURAL
EN6INEENfI�
2033 Sixth Ave. Ste 995
Seattle, WA 98121
Q
Z
O
W
J
H
M
N
N
M
DEDICATED
APPROVAL
STAMP S PAC E
LEVEL 2
FRAMING
`►
9532 231 ST PL SW,
EDMONDS, WA
PERMIT #
DATE
S-
Scale 1 /4" = 1'-0"
.1F�RTE"�
MEMBER REPORT
Level 2 Framing, Beam 1
4 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam® LVL
PASSED
t
1❑
Qverall LengTh: 1�' a'
12' 10"
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
0
Design Results
Actual @Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3793 @ 1 1/2"
8505 (3.00")
Passed (45%)
--
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
3212 @ 1' 1/4"
12303
Passed (26%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
12172 @ 6' 8"
22408
Passed (54%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.301 @ 6' 8"
0.327
Passed (L/522)
--
1.0 D + 1.0 L (All Spans)
Total Load DeFl. (in)
0.428 @ 6' 8"
0.654
Passed (L/367)
--
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Member should be side -loaded from both sides of the member or braced to prevent rotation.
SUppOrtS
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 -Stud wall - HF
3.00"
3.00"
1.50"
1126
2667
3793
Blocking
2 -Stud wall - HF
3.00"
3.00"
1.50"
1126
2667
3793
Blocking
• Blocking Panels are assumed to carry no loads applied directry above them and the tuu load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
Continuous
Bottom Edge (Lu)
Continuous
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 -Self Weight (PLF)
0 to 13' 4"
N/A
18.9
--
1 -Uniform (PSF)
0 to 13' 4" (Front)
10'
15.0
40.0
Default Load
RECEIVED
Nov 02 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
+
a
System :Floor
Member Type :Flush Beam
Building Use :Residential
Building Code :IBC 2018
Design Methodology : ASD
We erhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser. com/wood prod ucts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWE6 Software Operator
ForteWE6 Software Operator
Job Notes
Steven Nickolas
Bykonen Carter Quinn
(206) 264-7784
ssn@bcq-se.com
10/18/2021 7:31:50 PM UTC
ForteWE6 v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: McKinley Remodel
Paget/4
.1FDRTE"�
MEMBER REPORT
Level 2 Framing, Beam 3
4 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam® LVL
PASSED
t
Qverall Length: 13 1 D'
15' 3"
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
2435 @ 2"
9923 (3.50")
Passed (25%)
--
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
2109 @ 1' 3/4"
12303
Passed (17%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
9239 @ 7' 11"
22408
Passed (41%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)
0.307 @ 7' 11"
0.387
Passed (L/607)
--
1.0 D + 1.0 L (All Spans)
Total Load DeFl. (in)
0.449 @ 7' 11"
0.775
Passed (L/414)
--
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Member should be side -loaded from both sides of the member or braced to prevent rotation.
SUppOrtS
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 -Stud wall - HF
3.50"
3.50"
1.50"
773
1663
2436
Blocking
2 -Stud wall - HF
3.50"
3.50"
1.50"
773
1663
2436
Blocking
• Blocking Panels are assumed to carry no loads applied directry above them and the tuu load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
Continuous
Bottom Edge (Lu)
Continuous
Vertical Loads
Location (Side)
Tributary Width
Dead
(0.90)
Floor Live
(1.00)
Comments
0 -Self Weight (PLF)
0 to 15' 10"
N/A
18.9
--
1 -Uniform (PSF)
0 to 15' 10" (Front)
5' 3"
15.0
40.0
Default Load
RECEIVED
Nov 02 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
System :Floor
Member Type :Flush Beam
Building Use :Residential
Building Code :IBC 2018
Design Methodology : ASD
We erhaeuser Notes
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser. com/wood prod ucts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWE6 Software Operator
ForteWE6 Software Operator
Job Notes
Steven Nickolas
Bykonen Carter Quinn
(206) 264-7784
ssn@bcq-se.com
10/18/2021 7:31:50 PM UTC
ForteWE6 v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: McKinley Remodel
Page4/4
.1FDRTE"�
PASSED
t
MEMBER REPORT
Level 2 Framing, Beam 2
4 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam® LVL
Qverall Length: 1=
14'
0
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
Design Results
Actual @Location
Allowed
Result
LDF
Load: Combination (Pattern)
Member Reaction (Ibs)
3423 @ 14' S"
9923 (3.50")
Passed (34%)
--
1.0 D + 1.0 L (All Spans)
Shear (Ibs)
3325 @ 13' 6 1/4"
12303
Passed (27%)
1.00
1.0 D + 1.0 L (All Spans)
Moment (Ft-Ibs)
12639 @ 10' 6"
22408
Passed (56%)
1.00
1.0 D + 1.0 L (All Spans)
Live Load Defl.(in)
0.292 @ 7'SO 11/16"
0.356
Passed (L/586)
--
1.0 D + 1.0 L (All Spans)
Total Load DeFl. (in)
0.432 @ 7' SO 3/8"
0.712
Passed (L/396)
--
1.0 D + 1.0 L (All Spans)
• Deflection criteria: LL (L/480) and TL (L/240).
• Member should be side -loaded from both sides of the member or braced to prevent rotation.
SUppOrtS
Bearing Length
Loads to Supports (Ibs)
Accessories
Total
Available
Required
Dead
Floor Live
Total
1 -Stud wall - HF
3.50"
3.50"
1.50"
593
1122
1715
Blocking
2 -Stud wall - HF
3.50"
3.50"
1.50"
1100
2323
3423
Blocking
• Blocking Panels are assumed to carry no loads applied directry above them and the tuu load is applied to the member being designed.
Lateral Bracing
Bracing Intervals
Comments
Top Edge (Lu)
Continuous
Bottom Edge (Lu)
Continuous
Dead
Floor Live
Vertical Loads
Location (Side)
Tributary Width
(0.90)
(1.00)
Comments
0 -Self Weight (PLF)
0 to 14' 7"
N/A
18.9
--
1 -Uniform (PSF)
0 to 14' 7" (Front)
1' 4"
15.0
40.0
Default Load
2 -Point (Ib)
10' 6" (Front)
N/A
1126
2667
Linked from: Beam
1, Support 2
RECEIVED
Nov 02 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
+
a
System :Floor
Member Type :Flush Beam
Building Use :Residential
Building Code :IBC 2018
Design Methodology : ASD
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser. com/wood prod ucts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWE6 Software Operator
ForteWE6 Software Operator
Job Notes
Steven Nickolas
Bykonen Carter Quinn
(206) 264-7784
ssn@bcq-se.com
10/18/2021 7:31:50 PM UTC
ForteWE6 v3.2, Engine: V8.2.0.17, Data: V8.1.0.16
Weyerhaeuser File Name: McKinley Remodel
Page3/4