For Reference-BLD2023-1065+Arch Plans+8.27.2023_12.40.22_PM+3749456TYPICAL ABBREVIATIONS
&
AND
ETR
EXISTING TO REMAIN
MH
MANHOLE
SF
SQUARE FOOT (FEET)
@
AT
EXC
EXCAVATE/-ED/-ION
MIN
MINIMUM
SH
SHOWER
#
POUND/ NUMBER
EXH
EXHAUST HOOD
MIR
MIRROR
SHD
SHOWER HEAD
ABV
ABOVE
EXP
EXPANSION
MISC
MISCELLANEOUS
SHT
SHEET
ACOUS
ACOUSTICAL
EXT
EXTERIOR
MO
MASONRY OPENING
SHTG
SHEATHING
ACT
ACOUSTICAL CEILING TILE
FA
FIRE ALARM
MONO
MONOLITHIC
SIM
SIMILAR
ADD
ADDENDUM
FB
FIRE BLANKET
MTL
METAL
SL
SEALER
ADDL
ADDITIONAL
FBR
FACE BRICK
MPC
METAL PAN CEILING
SLNT
SEALANT
ADJ
ADJUSTABLE/ADJACENT
FD
FLOOR DRAIN
MTD
MOUNTED
SLV
SLEEVE
ADMIN
ADMINISTRATION
FDN
FOUNDATION
MULL
MULLION
SM
SURFACE MOUNTED
AFF
ABOVE FINISH FLOOR
FDV
FIRE DEPARTMENT VALVE
(N)
NEW
SNC
SANITARY NAPKIN CABINET
AHU
AIR HANDLING UNIT
FE
FIRE EXTINGUISHER
MTL
METAL
SND
SANITARY NAPKIN DISPOSER
ALT
ALTERNATE
FGS
FOAM GASKET SEAL
MPC
METAL PAN CEILING
SOG
SLAB ON GRADE
ALUM
ALUMINUM
FH
FIRE HOSE
MTD
MOUNTED
SP
STANDPIPE
ANUN
ANUNCIATOR
FHC
FIRE HOSE CABINET
MULL
MULLION
SPC
SPECIMEN PASS THROUGH
AP
ACCESS PANEL
FHV
FIRE HOSE VALVE
(N)
NEW
CABINET
APROX
APPROXIMATE
FIN
FINISH
NA
NOT APPLICABLE
SPEC
SPECIFICATIONS
ARCH
ARCHITECTURAL/ ARCHITECT
FIXT
FIXTURE
NIC
NOT IN CONTRACT
SPR
SINGLE PLY ROOF
BD
BOARD
FL
FLOOR
NO
NUMBER
SO.
SQUARE
BFE
BOTTOM FOOTING ELEVATION
FLASH
FLASHING
NOM
NOMINAL
SO. YD
SQUARE YARD
BG
BUMPER GUARD
FLEX
FLEXIBLE
NRC
NOISE REDUCTION COEFFICIENT
SR
SIDEWALL REGISTER
BLDG
BUILDING
FLG
FLANGE
NT
NOTE
SSTL
STAINLESS STEEL
BLKG
BLOCKING
FLUOR
FLUORESCENT
NTS
NOT TO SCALE
ST
STREET
BLW
BELOW
FOIC
FURNISHED BY OWNER-
OC
ON CENTER
ST
STONE TILE
BM
BEAM
INSTALLED BY CONTRACTOR
OD
OUTSIDE DIAMETER
STC
SOUND TRANSMISSION
BO
BOTTOM OF
FP
FIRE PROOFING
OFCI
OWNER FURNISHED -
COEFFICIENT
BOT
BOTTOM
FRMG
FRAMING
CONTRACTOR INSTALLED
STD
STANDARD
BR
BRICK
FS
FLOOR SINK
OFF
OFFICE
STL
STEEL
BSMT
BASEMENT
FSTOP
FIRESTOPPING
OH
OVERHEAD
STN
STONE
BTWN
BETWEEN
FT
FOOT/FEET
OP
OPERABLE PARTITION
STOR
STORAGE
C
CHANNEL
FTG
FOOTING
OPNG
OPENING
STRUCT STRUCTURAL
CAB
CABINET
FURR
FURRING
OPP
OPPOSITE
STS
STEEL STRUCTURE
CANTL
CANTILEVER
FUT
FUTURE
ORD
OVERFLOW ROOF DRAIN
SW
STEEL WINDOWS
CAT
CATEGORY
GA
GAUGE
PART
PARTITION
SW
SWITCH
CCTV
CLOSED CIRCUIT TELEVISION
GAL
GALLONS
PC
PRECAST CONCRETE
SWD
SOFTWOOD
CD
COILING DOOR
GALV
GALVANIZED
PED
PEDESTAL
SYM
SYMMETRICAL
CG
COILING GRILLE
GB
GRAB BAR
PL
PROPERTY LINE
T
TOP
CG
CORNER GUARD
GB
GRADE BEAM
PLAM
PLASTIC LAMINATE
TAN
TANGENT
CH
COAT HOOK
GC
GENERAL CONTRACTOR
PLBG
PLUMBING
TBD
TACKBOARD
CJT
CONTROLJOINT
GENR
GENERATOR
PLS
PLASTER
TC
TIME CLOCK
CL
CENTER LINE
GEN
GENERAL
PLW
PLYWOOD
TCAB
TOWEL CABINET
CLG
CEILING
GL
GLASS
PNL
PANEL
TDISP
TISSUE DISPENSER
CLR
CLEAR
GMU
GLASS MASONRY UNIT
PR
PAIR
TDR
TRENCH DRAIN
CM
CONSTRUCTION MANAGER
GR
GRADE
PRELIM
PRELIMINARY
TEL
TELEPHONE
CO
CASED OPENING
GWB
GYPSUM WALLBOARD
PRESS
PRESSURE
TEMP
TEMPERATURE
COL
COLUMN
H
HEIGHT/HIGH
PRIM
PRIMARY
TER
TERRAZZO
CONC
CONCRETE
HB
HOSE BIB
PROJ
PROJECTION
T&G
TONGUE & GROOVE
CONF
CONFERENCE
HD
HAND DRYER
PRV
POWER ROOF VENTILATOR
THRES
THRESHOLD
CONN
CONNECT/-ED/-ION
HDR
HEADER
PNT
PAINT
TPH
TOILET PAPER HOLDER
CONST
CONSTRUCTION
HDW
HARDWARE
PTR
PRINTER
TR
TREAD
CONT
CONTINUE/OUS
HM
HOLLOW METAL
PVC
POLYVINYL CHLORIDE
TRANSF TRANSFORMER
CONTR
CONTRACT/OR
HORIZ
HORIZONTAL
R
RADIUS
TS
TUBE SECTION
COORD
COORDINATE
HPT
HIGH POINT
RA
RETURN AIR
TV
TELEVISION
CORR
CORRIDOR
HR
HANDRAIL
RB
RESILIENT BASE
TYP
TYPICAL
CPT
CARPET
HT
HEIGHT
RD
ROOF DRAIN
UC
UNDERCUT
CT
CERAMIC TILE
HTR
HEATER
RE
RELOCATE EXISTING
UFD
UNDER FLOOR DUCT
CTR
CENTER
HVAC
HEATING, VENTILATING, AIR
PR
PAIR
UG
UNDERGROUND
CTSK
COUNTERSUNK
CONDITIONING
PRELIM
PRELIMINARY
UH
UNIT HEATER
CW
CURTAIN WALL
HW
HOT WATER
PRESS
PRESSURE
UNFIN
UNFINISHED
CYL
CYLINDER
IC
INTERCOM
PRIM
PRIMARY
UNO
UNLESS NOTED OTHERWISE
D
DEPTH OR DEEP
ID
INSIDE DIAMETER
PROJ
PROJECTION
UON
UNLESS OTHERWISE NOTED
DEMO
DEMOLITION
IN
INCH
PRV
POWER ROOF VENTILATOR
UTIL
UTILITY
DPR
DEPRESSION
INSUL
INSULATION
PNT
PAINT
UTIL
UTILITY
DEPT
DEPARTMENT
INT
INTERIOR
PTR
PRINTER
VC
VALVE CABINET
DF
DRINKING FOUNTAIN
ISO
ISOLATION
PVC
POLYVINYL CHLORIDE
VENT
VENTILATION
DIA
DIAMETER
JAN
JANITOR
R
RADIUS
VERT
VERTICAL
DIAG
DIAGONAL
JST
JOIST
RA
RETURN AIR
VEST
VESTIBULE
DIFF
DIFFUSER
JT
JOINT
RB
RESILIENT BASE
VIF
VERIFY IN FIELD
DIM
DIMENSION
KO
KNOCK OUT
RD
ROOF DRAIN
VTR
VENT THROUGH ROOF
DISP
DISPENSER
L
ANGLE
RE
RELOCATE EXISTING
W
WIDTH/WIDE
DIST
DISTRIBUTION
LAV
LAVATORY
REC
RECESSED
W
WIDE FLANGE
DIV
DIVISION
LB(S)
POUND (S)
REF
REFERENCE
W/
WITH
DN
DOWN
LCD
LINEAR CEILING DIFFUSER
REFR
REFRIGERATOR
W/O
WITHOUT
DP
DEMOUNTABLE PARTITION
LIN
LINEAR
REG
REGISTER
WC
WATER CLOSET
DR
DOOR
LKR
LOCKER
REINF
REINFORCE/-ED/-ING
WC
WALL COVERING
DS
DOWNSPOUT
LOC
LOCATION OR LOCATE
REM
REMOVE
WD
WOOD
DWG
DRAWING
LPT
LOW POINT
READ
REQUIRED
WDW
WINDOW
(E)
EXISTING
LTG
LIGHTING
RET
RETAINING
WG
WALL GUARD
EA
EACH
LVR
LOUVER
REV
REVERSE
WH
WALL HYDRANT
EC
ELECTRIC CABINET
LWC
LINEAR WOOD CEILING
REV
REVISE
WHCH
WHEELCHAIR
EF
EXHAUST FAN
M
MIDDLE
RF
RESILIENT FLOOR
WHTR
WATER HEATER
EIFS
EXTERIOR INSULATION AND
MAN
MANUAL
RH
ROOF HATCH
WP
WATERPROOF
FINISH SYSTEM
MATL
MATERIAL
RM
ROOM
WR
WASTE RECEPTACLE
EJT
EXPANSION JOINT
MAX
MAXIMUM
RO
ROUGH OPENING
WS
WEATHERSTRIP
EL
ELEVATION
MBD
MARKER BOARD
RS
ROUGH SLAB
WSCT
WAINSCOT
ELEC
ELECTRICAL
MC
MEDICINE CABINET
RWC
RAIN WATER CONDUCTOR
WT
WINDOW TREATMENT
ELEV
ELEVATOR
MCU
MODULAR COOLING UNIT
SCHED
SCHEDULE
WT
WEIGHT
EMERG
EMERGENCY
MECH
MECHANICAL
SD
SHOWER DRAIN
WWF
WELDED WIRE FABRIC
ENCL
ENCLOSURE
MEMB
MEMBRANE
SD
SMOKE DAMPER
ENTR
ENTRANCE
MEZZ
MEZZANINE
SDISP
SOAP DISPENSER
EQ
EQUAL
MFR
MANUFACTURER
EQUIP
EQUIPMENT
SYMBOL LEGEND
N
NORTH ARROW
O
CD REVISION CLOUD
Room name
123 ROOM TAG
1
1 A101 1 EXTERIOR ELEVATION
REFERENCE
1
1
1 A1.0 1 INTERIOR ELEVATION
REFERENCE
1
SIM
1
EXISTING CONSTRUCTION A10.1 DATUM POINT
DETAIL PLAN/SECTION
CALLOUT
EXISTING CONSTRUCTION 12'-0" SPOT ELEVATION
TO BE DEMOLISHED
1i WALL / ASSEMBLY SO SMOKE/CO
NEW CONSTRUCTION REFERENCE. (� DETECTOR
EXIT SIGN (DIRECTION ARROW)
KEYNOTE REFERENCE
O
SIM BUILDING SECTION FIRE EXTINGUISHER CABINET
1 RE. 906.3 OF FIRE CODE)
REFERENCE
A4.0 101a WINDOW TAG
EF EXHAUST FAN
µ 101 DOOR TAG $T LIGHT SWITCH
1t
DUPLEX OUTLET
ALIGN ALIGN WITH ESTABLISHED
STRUCTURAL GRID
+ SURFACES (TGFI LIGHT SWITCH
ELECTRICAL 10
CEILING HEIGHT - 0 r ri
MATL. AND FINISH PANEL/METER
BUILDING & ZONING SUMMARY
LAND USE DATA:
ZONE:
BD3, WITHIN DOWNTOWN ALLIANCE BOUNDARY
LEGAL DESCRIPTION:
(SEC 26 TWP 27 RGE 03RT-413) BEG 350 FT S & 30 FT W OF NE COR NE1/4 NE 1/4 TH
W 120 FT TH S 112 FT TH E 120 FT TH N 112 FT TO TPB
PRESENT USE: 581 Eating Places (PER SNOHOMISH COUNTY RECORDS)
FLOOR AREA:
SUITE B + C
1,668 SF
PARKING:
NO CHANGES PROPOSED.
NO NEW PARKING REQUIRED PER EDMONDS CITY CODE 17.50.010.C.2.
BUILDING DATA:
CONSTRUCTION TYPE:
VB (NOT SPRINKLERED)
PROJECT CODE SUMMARY DRAWING INDEX
ALL WORK TO BE COMPLETED IN COMPLIANCE WITH THE FOLLOWING CODES AND REGULATIONS AS A0.1 GENERAL INFORMATION
AMENDED OR MODIFIED BY THE GOVERNING BODY, APPROVING AND INSPECTING THE PROJECT: A0.4 CLEARANCE AND MOUNTING HEIGHTS
A0.5 LIFE SAFETY PLAN
EDMONDS CITY CODE 2018 INTERNATIONAL FIRE CODE A1.1 EXISTING - DEMO FLOOR PLAN
2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL MECHANICAL CODE
2020 INTERNATIONAL ELECTRICAL CODE 2018 UNIFORM PLUMBING CODE A2.1 FLOOR PLAN LEVEL 1
2018 WASHINGTON STATE ENERGY CODE 2018 INTERNATIONAL EXISTING BUILDING CODE A2.2 RCP LEVEL 1
A3.0 ELEVATIONS
ENERGY CODE COMPLIANCE SUMMARY
PROJECT SCOPE INCLUDES LIMITED PRESCRIPTIVE ALTERATIONS TO THE EXISTING
BUILDING ENVELOPE AND BUILDING SYSTEMS. ALL NEW OR ALTERED ENVELOPE
COMPONENTS TO COMPLY WITH APPLICABLE PRESCRIPTIVE PATH ENERGY CODE
REQUIREMENTS PER C402.1.3 & C402.4. NO CHANGES PROPOSED TO SPACE
CONDITIONING OR THE AMOUNT OF CONDITIONED SPACE WITHIN THE
BUILDING. LIGHTING WILL BE REPLACED AND/OR SUPPLEMENTED WITH HIGH -
EFFICIENCY LED FIXTURES AS NECESSARY FOR TENANT USE. LIGHTING CONTROLS
IN ACCORDANCE WITH C405.2, LIGHTING POWER PER C405.4. RECEPTACLES TO
BE CONTROLLED IN ACCORDANCE WITH C405.10 REQUIREMENTS.
PARCEL # 27032600100800 TENANT IMPROVEMENT AREA: SUITE B & C
610 5TH AVE S
EDMONDS, WA NO SITE ALTERATIONS PROPOSED.
5TH AVE S
SITE PLAN
i^ = 20'-0"
SECTION MATERIAL INDICATIONS
I . a. CONCRETE
a
INSULATION (LOOSE OR BATT)
�m
,.
-
EARTH
INSULATION (RIGID OR SPRAYED)
SAND
GYPSUM WALL BOARD/PLASTER
BRICK/STONE
CARPET
CONCRETE BLOCK
ACOUSTIC TILE
STEEL/METAL
WOOD (FRAMING)
PLYWOOD
WOOD (BLOCKING)
WOOD (FINISH)
(E) FENCE & GATE AT
GARBAGE ENCLOSURE
(E) DRIVEWAY
LU
w
w
V)
J
J
w
(E) LANDSCAPE
PROJECT INFORMATION
ADDRESS:
610 5TH AVE S, SUITE B
EDMONDS, WA 98020-3404
OWNER:
IL VIALE - BRIAN TAYLOR AND LOUISE FAVIER
ASSESSOR'S TAX PARCEL NUMBER:
27032600100800
LEGAL DESCRIPTION:
(SEC 26 TWP 27 RGE 03RT-4B) BEG 350 FT S &
30 FT W OF NE COR NE1/4 NE 1/4 TH W 120
FT TH S 112 FT THE 120 FT TH N 112 FT TO
TPB
PROJECT DESCRIPTION:
TENANT IMPROVEMENT ALTERATIONS AS
REQUIRED FOR NEW BAR/ CAFE IN EXISTING
BAR /CAFE SPACE.
VICINITY MAP
S Edmonds Bowl,;
c Are Hardwarv s
Hertl,yeree,ore
Ghana Hyperbarics
Edmonds Autobody
v
dmonds Mane
` Attraction
I Y Tempoarily closes
� Siragic cca
,N Communities Group
!II way v Howell way
55'
y Miniatures &More
tcC Minie,ores store
A Si_.
� 511
A5
N 614
s�-
T � Nomeland Dr
N
a
s,9 X-Ray Northwest
MeW
� tlir� I su pply store
S 5,0
a
t
m
s
Barkada Edmonds ,a
Filipino - S$
609
II Viale
OWNER
Brian Taylor & Louise Favier
610 5th Ave S
Suite B&C
Edmonds, WA 98020
ARCH ITECT
ImURBANAOO
A R C H I T E C T S
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
2023.03.10
PERMIT SUBMITTAL SET
CONTRACTOR
TBD
PROJECT INFO
PROJECT NUMBER: TBD
INTAKE DATE: 2023.03.10
1111663 REGISTERED
AROHITECT
ANDREW OI
STATE OF
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
SHEET
GENERAL INFORMATION
A09 1
HORN,
STROBE,
SPEAKER
SWITCH, CARD
READER, FIRE N
ALARM,
LU
THERMOSTAT ^ z O
m
ELECTRICA rn o U LL ,)
L DATA O O
O
DEVICES ON A WALL DEVICES ABOVE RESTROOM
COUNTER
A002 ACCESSIBILITY -DEVICES
1/4" =1'-0"
2'-6"
MIRROR
1'-3"
1'-6"
SOAP
DISPENSER $ UNO
CLEAR
SPACE
o
TA - SINK AND MIRROR TA - SINK PLAN VIEW
F71
N
J
O
O Zi
M OO
0
O
H
TA - PAPER TOWEL DISPENSER AND
WASTE RECPTICAL
0
o �
TA - LAB COAT HOOK BARS
A002 ACCESSIBILITY -ACCESSORIES
1/4" = 1'-0"
2'-3"
MAX.
N
in
3'-4" GRAB
BARS
CONTROLS Z
611 io
GRAB 7
BA S
� rn
BENCH
- O N
O '
' S' - 0" CLR
—BENCH -
ROLL IN SHOWER ROLL IN SHOWER
A002 ACCESSIBILITY- SHOWERS
1/4" = V-0"
2'-6"
0
URINAL
MIN. Q Q
SCRE N
EQ EQ a z
J �
O cn
O
X J
Q
�O
Ln �
O
i
URNIAL MOU
TING HEIGHTS
BOLLARD WITH
CARD READER
AND DOOR
SWITCH
3'4" H BOLLARD
0
o ,
WITH DOOR
`n cn ACTUATOR
N` SWITCH
-
DEVICE ABOUT TYP. COUNTER W/SPLAS DOOR ACTUATOR SWITCH
INSTALL SO HEIGHEST
POINT OF CHANGING
TALBE WHEN OPEN IS 32"
TA- DIAPER CHANGING STATION
0
in
TA - MOP AND BROOM HOLDER
MAX.
MIN.
U
r, z_
o � �
00 a
M M
V)
DRINKING FOUNTAIN HEIGHTS
3' - 0"
1' - 6" CONTROLS
10" GRAB
BARS
BENCH ON
Q OPPOSITE
WALL
N
BENCH
� N
TRANSFER SHOWER
GRAB BARS TOILET PAPER
1' - 6" DISPENSER
SEAT COVER
DISPENSER SANITARY
NAPKIN
DISPOSAL
O -
r-I �
i l0 ,
N N
ADA TOILET MOUNTING HEIGHTS ADA TOILET MOUNTING HEIGHTS
J
U
0 0
o
J
O
o
�
z
O
U
O
TA -SANITARY NAPKIN DISPENSER
ir_a:rev Imp :0109110•11
5"- 1' - 3"
u allw;a►142I 1111►1reuuv_w
1' - 10"
- 611 CONTROLS
N
'a
4' - 0" CLR
TRANSFER SHOWER
5'-0"CLR
MIN.
1' -
ADA TOILET PLAIN
m
FIRE EXTINGUISHER
3'-0"
UNO
- EQ . EQ
TOILET PLAN
TOILET
PARTITION
M
FIRE EXTINGUISHER CABINET
II Viale
OWNER
Brian Taylor & Louise Favier
610 5th Ave S
Suite B & C
Edmonds, WA 98020
ARCH ITECT
URBANAOO
A R C H I T E C T S
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
2023.03.10
PERMIT SUBMITTAL SET
CONTRACTOR
TBD
PROJECT INFO
PROJECT NUMBER: TBD
INTAKE DATE: 2023.03.10
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
SHEET
CLEARANCE AND MOUNTING
HEIGHTS
URINAL STALL PLAN I
A002—ACCESSIBILITY --TOILETS AND
URINALS
1/4" = V-0"
A08
4
FLOOR PLAN - LEVEL 01 LIFE SAFETY
1/4" = V-0"
LIFE SAFETY - EGRESS NOTES:
ALL EGRESS DOORS SHALL PROVIDE A MINIMUM CLEAR
WIDTH OF 32"
ALL DOORS TO REMAIN OPERABLE IN THE DIRECTION
OF EGRESS TRAVEL WITHOUT REQUIRING SPECIAL
KNOWLEDGE OR KEYS
ANY ASSEMBLY OCCUPANCY AREAS SHALL HAVE THE
OCCUPANT LOAD OF EACH ROOM OR SPACE POSTED IN
A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT
ACCESS DOORWAY FROM THE ROOM OR SPACE.
STAIRWAYS SERVING 50 OR MORE OCCUPANTS SHALL
HAVE A MINIMUM CLEAR WIDTH OF 44 INCHES.
STAIRWAYS SERVING AN OCCUPANT LOAD OF LESS
THAN 50 SHALL HAVE A MINIMUM CLEAR WIDTH OF 36
INCHES.
RAISED CHARACTER AND BRAILLE EXIT SIGNS
COMPLYING WITH ICC A117.1 SHALL BE PROVIDED
ADJACENT TO EACH DOOR REQUIRING AN EXIT SIGN
AND AT ALL EXIT STAIRWAYS AND RAMPS.
LUMINAIRES TO BE INSTALLED AT ALL EXIT SIGNS AND
EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. SELF
LUMINOUS SIGNS TO BE LISTED AND LABELED IN
ACCORDANCE WITH UL 924 AND INSTALLED IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
EXTERNALLY ILLUMINATED SIGNS TO BE ILLUMINATED
AT AN INTENSITY OF
NOT LESS THAN 5 FOOTCANDLES ON THE FACE OF SIGN.
ILLUMINATION SHALL BE PROVIDED AT EVERY POINT IN
THE MEANS OF EGRESS. UNDER NORMAL POWER, THE
MEANS OF EGRESS ILLUMINATION LEVEL SHALL BE NOT
LESS THAN 1 FOOTCANDLE AT THE WALKING SURFACE.
MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED
WITH AN ON -SITE EMERGENCY POWER SYSTEM
CAPABLE OF PROVIDING POWER FOR NOT LESS THAN
90 MINUTES. UNDER EMERGENCY POWER, THE MEANS
OF EGRESS ILLUMINATION LEVEL SHALL BE NOT LESS
THAN AN AVERAGE OF 1 FOOTCANDLE AND A
MINIMUM OF 0.1 FOOTCANDLE MEASURED AT THE
WALKING SURFACE UPON INITIAL ACTIVATION.
ILLUMINATION LEVELS ARE PERMITTED TO DECLINE TO
0.6 FOOTCANDLE AVERAGE AND 0.06 FOOTCANDLE
MINIMUM AT THE END OF THE EMERGENCY LIGHTING
TIME DURATION. ILLUMINATION SHALL NOT EXCEED A
40:1 RATIO OF UNIFORMITY. REFER TO REFLECTED
CEILING PLANS FOR EGRESS LIGHTING LOCATIONS AND
ADDITIONAL CRITERIA.
PLUMBING DATA: (IBC TABLE 2902.1)
REQUIRED FIXTURES:
WATER CLOSETS
GROUP A-2 BAR
(GROUP B OCCUPANCY) 45 OCCUPANTS INSIDE + 34 OCCUPANTS OUTSIDE
1/40 M, 1/40 F
LEVEL 01 40(M) OCCUPANTS / 40 = 1 (M) REQUIRED
LEVEL 01 40(F) OCCUPANTS / 40 = 1 (F) REQUIRED
LAVATORIES
GROUP A-2 BAR
(GROUP B OCCUPANCY) 45 OCCUPANTS INSIDE + 34 OCCUPANTS OUTSIDE
1/75
LEVEL 01 79 OCCUPANTS / 75 = 2 REQUIRED
FIXTURE SUMMARY
WC:
1(M) = 1 REQUIRED < 2 PROVIDED*
1 (F) = 1 REQUIRED < 2 PROVIDED*
LAVATORIES:
2 REQUIRED = 2 PROVIDED*
*SECOND FIXTURE CAPACITY PROVIDED VIA SHARED FACILITIES IN THE
BUILDING AS INDICATED IN BUILDING OWNER'S APPROVAL LETTER,
INCLUDED WITH THIS PERMIT SUBMITTAL.
311 L" ] 101L0101814111 I_1014 L*5
SOUTH BUILDING (NON SEPARATED PER 508.3)
LEVEL B
GROUP B 1,668 SF
LEVEL 01
ALTERATION AREA: SUITES B+C
GROUP B 1,668 SF
NORTH BUILDING (SEPARATED PER 508.4)
LEVEL B
GROUPS F-1, B 2,064 SF
ALLOWABLE BUILDING HEIGHT AND AREA:
IBC TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET
ABOVE GRADE PLANE
(TYPE VB, PARTIALLY-SPRINKLERED BUILDING)
A, B, & F OCCUPANCIES 40'
TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE
GRADE PLANE
(TYPE VB, PARTIALLY-SPRINKLERED BUILDING)
A-2 2
B 2
F-1 1
SBC TABLE 506.2 ALLOWABLE AREA FACTOR IN SQUARE
LEVEL 01 FEET
GROUP A-2 2,564 SF (TYPE VB, PARTIALLY-SPRINKLERED BUILDING)
A-2 18,000 (SM)
B 9,000 (INS)
TOTAL BUILDING AREA: 7,964 SF F 8,500 (INS)
TOTAL BUILDING AREA (7,964 SF) < MAXIMUM
ALLOWABLE AREA OF MOST RESTRICTIVE OCCUPANCY
(8,500 SF)
OCCUPANCY LEGEND (PROPOSED)
SUITE B
OCCUPANCY GROUP
OCCUPANT LOADS PER SBC TABLE 1004.1.2
B (BAR / CAFE)
ASSEMBLY
(FIXED BOOTH SEATING) 24"/OCCUPANT
+/- 64 LF
(BAR SEATING) 18"/OCCUPANT
IN,
+/- 13.5 LF
41 OCCUPANTS
B (KITCHEN)
KITCHEN, COMMERCIAL: 200 GSF/OCCUPANT
531 SF
2.7 OCCUPANTS
B (OFFICE)
BUSINESS AREAS: 150 GSF/OCCUPANT
69 SF
0.5 OCCUPANTS
TOTAL OCCUPANT LOAD: 45 PERSONS PER TABLE 1004.5
FIRE EXTINGUISHERS TO BE SIZED AND LOCATED IN
ACCORDANCE WITH IBC 906.3 AND NFPA 10
REQUIREMENTS. CABINETS PROJECTING > 4" FROM
ADJACENT WALL SURFACES TO BE LOCATED WITH
BOTTOM EDGE < 27" A.F.F. ALL COMPONENTS
REQUIRING ACCESSIBLE REACH TO BE LOCATED </= 48"
& >/= 15" A.F.F. PER ANSI A117.2009 SECTION 308.
II Viale
OWNER
Brian Taylor & Louise Favier
610 5th Ave S
Suite B&C
Edmonds, WA 98020
ARCHITECT
URBANAOO
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
2023.03.10
PERMIT SUBMITTAL SET
CONTRACTOR
TBD
PROJECT INFO
PROJECT NUMBER: TBD
INTAKE DATE: 2023.03.10
11663 REGISTERED
ITECT
ANDREW OLIVE AW NC
STATE OF VVAS IN TOI
� 2
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
SHEET
A095
0' 2' 4' 8' 16'
Q
II Viale
—(E) WATE
(ABOVE)
PROPERTY LINE
FLOOR PLAN - LEVEL 01 EXISTING -DEMO
1/4" = P-0"
GENERAL FLOOR PLAN NOTES
1. ALL DIMENSIONS TO EXISTING WALLS, WINDOWS, DOORS, AND OTHER BUILDING ELEMENTS ARE TO BE CONSIDERED APPROXIMATE,
AND ARE TO BE VERIFIED IN THE FIELD.
2. ALL WINDOWS AND DOORS THAT ARE EXISTING, TO BE REPLACED, ARE TO BE VERIFIED IN THE FIELD (MATCH HEIGHT, WIDTH,
LOCATION, AND POSITION). CONTRACTOR TO VERIFY ANY DESCREPANCIES WITH ARCHITECT PRIOR TO ORDERING.
3. ALL PLAN DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED
AS "CLEAR" (CLR) AND DIMENSIONS AT EXISTING FINISHED SURFACES TO REMAIN ARE TO FACES OF FINISHED MATERIALS.
4. NO ALTERATIONS TO GRADE, OR GROUND DISTURBANCE U.N.O.
5. ALL INTERIOR STUD WALLS TO BE NOMINAL 2x DIMENSION LUMBER @ 16" OC W/ 5/8" TYPE X GWB ON BOTH SIDES U.N.O.
6. WHERE EXPOSED DURING CONSTRUCTION, EXISTING CEILING OR WALL CAVITIES AT THE BOUNDARY BETWEEN CONDITIONED AND
UNCONDITIONED AREAS SHALL BE INSULATED TO FULL DEPTH WITH INSULATION HAVING A NOMINAL VALUE OF R-3.0 PER INCH PER
C503.1 ITEM 3.
2
EXISTING FENCE @ PROPERTY LINE,
TO REMAIN
A3.0
PLAN LEGEND
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
VT SPACE
T SCOPE
OWNER
Brian Taylor & Louise Favier
610 5th Ave S
Suite B&C
Edmonds, WA 98020
ARCHITECT
URBANAOO
A R C H I T E C T S
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
2023.03.10
PERMIT SUBMITTAL SET
CONTRACTOR
TBD
PROJECT INFO
PROJECT NUMBER: TBD
INTAKE DATE: 2023.03.10
1\166,3 REGISTERED
AROHITECT
ANDREW OLIVE Aw NCE
STATE OF WAS IN 10N
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
SHEET
EXISTING - DEMO FLOOR PLAN
0' 2' 4' 8' 1 6'
A191
n
u
N
WALK IN COOLER,
UNDER SEPARATE PERMIT
FLOOR PLAN - LEVEL 01
GENERAL FLOOR PLAN NOTES
1. ALL DIMENSIONS TO EXISTING WALLS, WINDOWS, DOORS, AND OTHER BUILDING ELEMENTS ARE TO BE CONSIDERED APPROXIMATE,
AND ARE TO BE VERIFIED IN THE FIELD.
2. ALL WINDOWS AND DOORS THAT ARE EXISTING, TO BE REPLACED, ARE TO BE VERIFIED IN THE FIELD (MATCH HEIGHT, WIDTH,
LOCATION, AND POSITION). CONTRACTOR TO VERIFY ANY DESCREPANCIES WITH ARCHITECT PRIOR TO ORDERING.
3. ALL PLAN DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED
AS "CLEAR" (CLR) AND DIMENSIONS AT EXISTING FINISHED SURFACES TO REMAIN ARE TO FACES OF FINISHED MATERIALS.
4. NO ALTERATIONS TO GRADE, OR GROUND DISTURBANCE U.N.O.
5. ALL INTERIOR STUD WALLS TO BE NOMINAL 2x DIMENSION LUMBER @ 16" OC W/ 5/8" TYPE X GWB ON BOTH SIDES U.N.O.
6. WHERE EXPOSED DURING CONSTRUCTION, EXISTING CEILING OR WALL CAVITIES AT THE BOUNDARY BETWEEN CONDITIONED AND
UNCONDITIONED AREAS SHALL BE INSULATED TO FULL DEPTH WITH INSULATION HAVING A NOMINAL VALUE OF R-3.0 PER INCH PER
C503.1 ITEM 3.
1
A3.0
PLAN LEGEND
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
EQUIPMENT SCHEDULE
# DESCRIPTION NOTES
1
HAND WASH SINK
VERIFY DIMS TO PROVIDE 30"x42" CLEARANCE CENTERED
ON SINK W/O ENCROACHING ON TOILET CLEARANCE
2
FLOOR SINK
3
DUMP SINK
4
THREE COMPARTMENT SINK
5
PRODUCE SINK
6
MEAT / FISH SINK
7
ICE BIN
8
ICE MAKER
9
MOP SINK
10
UNDERCOUNTER DISHWASHER
LOW TEMP (AUTO-CHLOR U34 MODEL)
11
MOP SINK
12
SURFACE MT DRIP TRAY W/ GLASS
RINSE
13
COLD + HOT WATER DISPENSER
14
UNDERCOUNTER FRIDGE - 2DR
15
SANDWICH PREP REFRIGERATOR
16
UNDERCOUNTER FRIDGE
17
ESPRESSO MACHINE
18
SANDWICH PREP REFRIGERATOR
19
MODULAR WALK-IN COOLER
20
UNDERCOUNTER FRIDGE
DOOR SCHEDULE
MARK
PHASE
HEIGHT
FWIDTH NOTES
Exterior
06
Existing
6'-8"
3--0" NO CLOSER (TO MAINTAIN ACCESIBILITY)
07
Existing
6'- 8"
3' - 0"
Interior
01
Existing
6' - 8"
3' - 0"
05
Existing
6' - 8"
3' - 0"
04
New
7' - 0"
3'- 0"
NO CLOSER (TO MAINTAIN ACCESIBILITY)
Construction
WINDOW SCHEDULE
NUMBER
PHASE
WIDTH
HEIGHT
SILL HEIGHT
TEMPERED
U-VALUE
SHGC
NOTES
FLOOR PLAN - LEVEL 01
01
New Construction
3' - 8"
6-0"
1--6"
YES
0.30
0.38
02
New Construction
3' - 8"
6-0"
1--6"
YES
0.30
0.38
* U-VALUES & SHGC ARE MAXIMUMS
II Viale
OWNER
Brian Taylor & Louise Favier
610 5th Ave S
Suite B & C
Edmonds, WA 98020
ARCH ITECT
URBANAOO
ARCHITECTS
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
2023.03.10
PERMIT SUBMITTAL SET
CONTRACTOR
TBD
PROJECT INFO
PROJECT NUMBER: TBD
INTAKE DATE: 2023.03.10
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
SHEET
5Kole] :M1W_\0111kyja01
0' 2' 4' 8' 16'
A291
WALK-IN COOLER LIGHTING, PROVIDED BY
VENDOR, UNDER SEPARATE PERMIT
RCP LEVEL 01
1/4" _ V_0"
LIGHTING & ELECTRICAL NOTES
1. ALL LIGHTS TO BE HIGH -EFFICIENCY, DIMMABLE LED, 3,000 KELVIN, CRI >/= 90 U.O.N.
2. ALL DECORATIVE LUMINAIRES TO BE OWNER FURNISHED, CONTRACTOR INSTALLED (OFCI)
U.O.N.
3. OCCUPANT SENSOR CONTROLS REQUIRED IN THE FOLLOWING AREAS PER C405.2.1:
ENCLOSED OFFICES, ENCLOSED ROOMS 300 FT OR LESS (PANTRY AREA), RESTROOMS,
STORAGE ROOMS. OCCUPANT SENSORS TO REDUCE LIGHTING LOAD BY 50% WHEN
UNOCCUPOED AND TURN LIGHTING 100% OFF WHEN SPACE IS UNOCCUPIED FOR 20 MINUTES.
CONFIGURED TO TURN ON AT 50% POWER EXCEPT IN RESTROOMS, LOBBIES, AND AREAS
WHERE SAFETY WOULD BE ENDANGERED. OCCUPANT CONTROL TO ALLOW MANUAL OFF.
4. TIME SWITCH CONTROLS PER C4052.2.2 REQUIRED IN ALL AREAS W/O OCCUPANT SENSOR
CONTROLS EXCEPT WHERE LIGHTING IS INTENDED FOR CONTINUOUS OPERATION. TIME
SWITCH CONTROLS TO TURN LIGHTS 100% OFF DURING UNOCCUPIED HOURS. PROVIDE
OVERRIDE CONTROLS WITH READY ACCESS TO OCCUPANTS SERVING AREAS NO GREATER THAN
5,000 SF.
5. ALL LIGHTING TO HAVE MANUAL CONTROLS WITH READY ACCESS TO OCCUPANTS AND THE
ABILITY TO REDUCE THE CONNECTED LIGHTING LOAD TO BETWEEN 30 AND 70 PERCENT.
LIGHTING LOAD REDUCTION CONTROLS NOT REQUIRED AT RESTROOMS OR STORAGE
ROOMS EXCEPT AS OTHERWISE NOTED.
6. DISPLAY AND ACCENT LIGHTING TO BE CONTROLLED INDEPENDENTLY FROM GENERAL AREA
LIGHTING AND OTHER LIGHTING APPLICATIONS WITHIN THE SAME SPACE.
SYMBOL LEGEND
8. PROVIDE MASTER CONTROL SWITCH (NOT CIRCUIT BREAKER) TO CONTROL ALL EF EXHAUST FAN
DINING/SEATING AREA LIGHTING AT BAR.
O SURFACE MOUNT FIXTURE
9. NO 20A CIRCUIT CONTROLLED BY A SINGLE SWITCH OR CONTROL TO BE LOADED >80%.
TABLE LAMP
10. PROJECT CLOSE OUT DOCUMENTATION IS REQURIED, INCLUDING WSEC LIGHTING
COMPLIANCE REPORTS THAT DOCUMENT ALL INTERIOR AND EXTERIOR LIGHING AREA AND/OR jj WALL MOUNT FIXTURE
SURFACE TYPES. LIGHITN POWER ALLOWANCES AND INSTALLED DENSITIES.
— — LINEAR SURFACE MOUNT LUMINAIRE
C405.4.1 TOTAL CONNECTED INTERIOR LIGHTING POWER
TCLP = [LVL + BILL + TRK + POE + Other]
LVL = LINE VOLTAGE LAMPS, MIN 60 LUMENS/WATT
BILL = RATED INPUT WATTAGE OF BALLAST
TRK = TRACK LIGHTING LUMINAIRES AS SPECIFIED, NO LESS THAN 16W/LF OR WATTAGE LIMIT OF
CURRENT LIMITING DEVICES, OR WATTAGE LIMIT OF TRANSFORMER
POE= MAX WATTAGE OF TRANSFORMER EXCEPT THAT FOR POE, POWER SUPPLIED TO ANY NON -
LIGHTING DEVICES MAY BE SUBTRACTED
Other = WATTAGE OF ALL OTHER LUMINAIRES
EXCLUSIONS FROM TCLP CALCULATION:
• EMERGENCY LIGHTING AUTOMATICALLY OFF DURING NORMAL BUILDING OPERATION
• ADVERTISING OR DIRECTIONAL SIGNAGE
• FOOD WARMING LIGHTS
• LIGHTING APPROVED BECAUSE OF SAFETY CONSIDERATIONS
• FURNITURE MOUNTED SUPPLEMENTAL TASK LIGHTING THAT IS CONTROLLED BY AUTOMATIC
SHUTOFF
• EXIT SIGNS
INTERIOR LIGHTING POWER ALLOWANCE, BUILDING AREA METHOD (WATTS/FTZ)
• DINING BAR LOUNGE/LEISURE = 0.79
0.79 WATTS / FT x 1,668 FT = 1,318 WATTS TOTAL ALLOWABLE
• L1
- SURFACE MOUNTED DECORATIVE PENDANT LUMINAIRE
(6) @ 20W =
120
• L2
- SURFACE MOUNTED LUMINAIRE
(13) @ 15W =
195
• L3
- WALL MOUNTED VANITY LIGHTING
(1) @ 50W =
50
• L4
- TABLE LAMPS
(13) @ 10W =
130
• L5
- SURFACE MOUNTED UTILITY LUMINAIRES
(6)@ 50W =
300
TCLP =
795 WATTS
795 WATTS ACTUAL < 1,318 WATTS ALLOWABLE
II Viale
OWNER
Brian Taylor & Louise Favier
610 5th Ave S
Suite B&C
Edmonds, WA 98020
ARCHITECT
URBANAOO
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
2023.03.10
PERMIT SUBMITTAL SET
CONTRACTOR
TBD
PROJECT INFO
PROJECT NUMBER: TBD
INTAKE DATE: 2023.03.10
R
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
SHEET
RCP LEVEL 1
7. WHEE TOTAL LIGHTING POWER DENSITY OF EGRESS LIGHTING IS >0.02 W/SF FIXTURES
REQUIRE SHUT OFF DURING UNOCCUPIED PERIODS.
0' 2' 4' 8' 1 6'
A292
II Viale
A B C D
FFF
J F
-I
�_
JL
JL
_JL_
—�
I
J
I
-1
�
J-
JL
_
_J _
_—
EXISTING ELEVATION - EAST
1/4" = V-0"
A B C
PROPOSED ELEVATION - EAST
1/4" =1'-0"
DEMO (E) OVERHEAD DOOR, TO BE REPLACED
D
(N) WINDOWS AT EXISTING FRAMED OPENING,
PER SCHEDULE
LOOR PLAN _LEVEL 01
0'-0"
LOOR PLAN - LEVEL 01
0'-0°
OWNER
Brian Taylor & Louise Favier
610 5th Ave S
Suite B & C
Edmonds, WA 98020
ARCH ITECT
URBANAOO
A R C H I T E C T S
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
2023.03.10
PERMIT SUBMITTAL SET
CONTRACTOR
TBD
PROJECT INFO
INTAKE DATE: 2023.03.10
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
SHEET
ELEVATIONS
0' 2' 4' 8' 16'
A390