Sno-Isle Edmonds Library - DFR 11-20-23 Steel.epoxy inspection report.& ASSOCIATES
INC.
GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING & INSPECTION
November 17, 2023
Mr. R.D. Burley (E-Mail)
SNO-ISLE LIBRARIES
7312 35' Avenue NE
Marysville, WA 98271
RE: CONSTRUCTION TESTING AND INSPECTION
Sno-Isle Edmonds Library
650 Main Street
Edmonds, Washington
Dear Mr. Burley,
KA No. 096-23544
Permit No. BLD2023-0399
In accordance with your request and authorization, our firm performed construction testing and inspection
for the above -referenced project. The sampling and testing was performed by our inspectors and reports
are included.
If you have any questions, or if we can be of further assistance, please do not hesitate to contact our
office.
Respectfully submitted,
KRAZAN & ASSOCIATES, INC.
4
1 k � 4__�
Jerry Gelder
Project Manager
Pacific Northwest Division
JG/lkj
C.C. FABER CONSTRUCTION (EMAIL)
JOHNSTON ARCHITECTS (EMAIL)
CITY OF EDMONDs
43031981h Street SW, Lynnwood, Washington 98036 • (425) 485-5519 • FAX (425) 485-6837
With Offices Serving the Western United States
09623544 DFR
Pagel of 2
w—Kywan &Associates, Inc.
Geotechnical Engineering a Environmental Engineering
Construction Testing and Inspection
Field
Report NO.: 09623544DFR1I 1623PS
DATE: 11/16/2023 Set Count: CONTRACTOR: Sno-Isle Libraries
PROJECT #: 09623544 PERMIT #: BLD2023-0399
PROJECT: Sno Isle Edmonds Litllrary INSPECTOR: Patrick Start
LOCATION: 650 Main St JURISDICTION: Edmonds
KA P.M.: Jeff Mercer WEATHER: TEMP:
Arrived on site, as per dispatch, to perform visual weld inspection and adhesive anchor inspection.
Weld Inspection
Performed visual weld inspection on L2 @ large meeting room. Visually inspected all welds and their
connections; beam to column, beam to beam, and kickers. All welds appeared to have the correct weld
size, profile and location, while also not containing any discontinuities. Welding was performed in
compliance with AWS D1.1 standards and details, as per S3.2. Refer to welding report
9623544SSR11162023PS.
Adhesive Anchor Inspection
Performed adhesive anchor inspection on Level 2 @ large meeting room. 24 total holes were drilled at 7
different locations. Holes were drilled to a diameter of 5/8" and a depth of 2" and properly cleaned before
the application of adhesive. Depth of slab reinforcement varied due to hollow areas in the slab. Hilti HIT
sleeves were used to address the areas that were hollow at certain depths. Sleeves were inserted into each
hole to receive the epoxy. Epoxy used was Hilti HIT-HY 270, exp. 7/31/24.
Offices Serving the Western United States
Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500
The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Kramn & Associates. This report
indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept
responsibility for validity of results. The same information has been provided by other; on site. The test results apply only to the specific locations, and items inspected or tested. Template date 11/12/2023
Page 2 of 2
'z1(�+�y.Cli� &As,sociates,Inc.
Geotechnical Engineering . Environmental Engineering
Construction Testing and Inspection
�ft
m 330 niiSM
vwbq.; 1111110:0m
r_ TsT. T_�Pia
Reviewed By: A., ASTM Test M
Field
Report NO.: 09623544DFR111623PS
Asset
To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and
regulatory requirements.
resentative: I Technician:
�- "
Offices Serving the Western United States
Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacorna (253) 939-2500
The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Kmazan & Associates. This report
indicates our inspector; observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept
responsibility for validity of results. The same information has been provided by others on site. The test results apply only to the specific locations, and items inspected or tested. Template date 11/12/2023
4W■ rAzm&Associates, Inc.
Geotechnical Engineering . Environmental Engineering
Construction Testing and Inspection
DATE: 11 /16/2023
PROJECT #: 09623544
PROJECT: Sno Isle Edmonds Library
LOCATION: 650 Main St
KA P.M.: Jeff Mercer
STRUCTURAL STEEL
❑✓ FIELD ❑ SHOP WELDING
Beam to column, beam to beam, kicker plates
L2 @ large meeting room
Welder qualification / certification verged for:
Position:
FLAT
VERTICAL
Process:
SMAW
FCAW
Weld Type:
FILLET
C.P.
Weld Size:
3/16"
1/4"
Codes:
AWS
AISC
❑✓ NOTES
WELDING INSPECTION
REPORT NO.: 09623544SSR111623-PS
CONTRACTOR: Sno Isle libraries
PERMIT*
INSPECTOR: Patrick Start
JURISDICTION: Edmonds
WEATHER: TEMP•
VISUAL ❑ MATERIAL ID
OVERHEAD HORIZONTAL Filler Metal:
SAW GMAW Other:
PLUG P.P. Other:
3/8" 5/16" Other:
ASME IBC Other:
DISCREPANCIES
100 % COMPLETE
1 welds appeared to have the correct weld size, profile and location, while also not containing any discontinuities. Welding was
rformed in compliance with AWS D1.1 standards and details, as per S3.2
Reviewed by:
To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements.
Superintendent/Representative:
Technician:
Offices Serving the Western United States
Lynnwood (425) 485-5519 . Poulsbo (360) 598-2126 • Tacoma (253) 939-2500
Suuctwal Sted Retort
Effective I11122023
7bc WG6 Wnprovidedo"tLimWn¢pmpvyfortheeaclmivetneofdwcEi Ibis repon mYmt be npmdumd many format whhom the wrdteapm Wi0nofNe chtm and Ko—&A,sy Wcs. Tbistgp fi diumyo hM=tonobsetvatiDnandtestugresftb.edonsdewodmoma i comaet—rviies
Thismfo=tionis"mitomiewpfwtofminknimi. Byaigftftrepon.mn®pectoes oidmlacreptrespowbifnyforvandkyof..ft, lb a—i fotmeionhesb—poQWbyoth-msuc. the a suhsapplyoNYtothespmificbcetiom,wdaemsimpWodmtened.