REV1 REVIEWED Hill Residence Calc Package 032123BYKONEN RE�;IBwEo.........., CARTER CITY OF EDMONDS QUINN BUILDING DEPARTMENT; STRUCTURAL ' ENGINEERING STRUCTURAL CALCULATIONS Linda Mackin Hill Addition 633 Alder St Edmonds, WA 98020 3/21/2023 ► 2033 Sixth Avenue #995 Seattle, WA 98121 206-264-7784 www.BGQ-SF.com T rearsetback r— -- ------T------- -- _-1 1 SW existing 1rdr.heA.r SW-t 1 A � I I I 1 --- -- -----+------------------------- EXISTING ROOF FRAMING r—— — — — — — — — --+----------- --1 -------------- -- t4 = N �2— — — — — — — — ————————— — — — ——I .(addition -h wit in3'ofexisting ^' eara¢e roof to be 1 11, A, �;; SW-1 FIATCEILING N 3- 2— 7 8 VAULT CEILING I I menmllanon I N[etlr . 1 I IIIi 1 walvenr�arSNa�e= calf i 8.aa1M 91 sa. reeuimi- _ _ i roal wn[uauoe w¢nl�ea-zaaov. _�skylRler PRE -MA UFACFURED ROOF TRUSS I I I I 1 o CQ: Don't need to use ^ asvagU mwaWanymore II II o x � � ' I I FIATCEILING_____________ 3 N N I 1 N VAULTC PRE -MA LING L 2348 attic) I UFACFURED ROOFTRUS � _ rT- —T d ——T�-tens I T — eyi.inJhdr N I I r�—r�— r�—r�— 3-1 2 X - BL ubula 1 r N II \ r ,-. FRteJ'I __ _ Don't need to use -, b.I r l a sh as hearwall anymore I I I I I I I I I F TCEI ING et1 bortdTfeedrtou'se �A—r -- � I I I I I I I I I I I ap shgamell anNmor j I I I I T—I— TI—I—T —I i� I I I I � I I I \I— —I— �, ` — I T — N \ O FLATCEILING II z I I I I I \I I I I I I Vz �\ —��—+ �— II1 2X12 P 24.O.C. I I I I I I I LL I I I I I I\ I I I I M I LL I I I FLdTGEIDN5 I I I I I II I I I I ICI I I I I I I\111�1 ICI I I I I I\I_I_I-- I — I I Imo_ ale. - 1 1 --4--i 1 t-17 I I r-r—i \ I T—T I I I I I I SW-3 SW-3 L II X \I I I 1 r rt rt 1 I I I I I I I I I C I I I I\ II I I T I I \I I I I I I 11 exl tingh r e ng ndr ng hd yL J— L-------- J L J J t.-.f Wili.n thin b'of property ine t. be 1 hour fire -rated U l� W N J; Yi Seismic (House) Project: Seismic Design Parameters Site Class D Risk Category II Importance Factor 1 Ss 1.285 S1 0.452 Fa 1.200 Fv 1.848 Sms 1.542 Sm1 0.835 Sds 1.028 Sd1 0.557 R 6.5 CS 0.158 k 1 Seismic Design Category D Seismic Weight Areas (ft) Roof 2632 Loads DL-Floor (psf) 15 DL-Solar (psf) 5 Wall Weight (psf) 15 () Half Wall Weight (psf) -7.5 Table 1.5-1 Table 1.5-2 From USGS Table 11.4-1 Table 11.4-2 Eq. 11.4-1 Eq. 11.4-2 Eq. 11.4-3 Eq. 11.4-4 Table 12.2-1 Eq. 12.8-2 12.8.3 Table 11.6-1 Seismic Base Shear Vultimate (k) 11.4 Eq. 12.8-1 Vallowable (k) 8.0 Level Weight (k) Height (ft) W.f., C„X FX (ult.) FX (allow.) Roof 72.38 8 579.0 1.00 11.4 8.0 TOTAL 72.4 - 579.0 1 11.4 8.0 All references are from ASCE 7-16: Minimum Design Loads and Associated Criteria for Buildings and Other Structures Seismic (Garage) Project: Seismic Design Parameters Site Class D Risk Category II Importance Factor 1 Ss 1.285 S1 0.452 Fa 1.200 Fv 1.848 Sms 1.542 Sm1 0.835 Sds 1.028 Sd1 0.557 R 6.5 CS 0.158 k 1 Seismic Design Category D Seismic Weight Areas (ft) Roof 742 Loads DL-Floor (psf) 15 DL-Solar (psf) 5 Wall Weight (psf) 15 () Half Wall Weight (psf) -7.5 Table 1.5-1 Table 1.5-2 From USGS Table 11.4-1 Table 11.4-2 Eq. 11.4-1 Eq. 11.4-2 Eq. 11.4-3 Eq. 11.4-4 Table 12.2-1 Eq. 12.8-2 12.8.3 Table 11.6-1 Seismic Base Shear Vultimate (k) 3.2 Eq. 12.8-1 Vallowable (k) 2.3 Level Weight (k) Height (ft) W.f., C„X FX (ult.) FX (allow.) Roof 20.405 10 204.1 1.00 3.2 2.3 TOTAL 20.4 - 204.1 1 3.2 2.3 All references are from ASCE 7-16: Minimum Design Loads and Associated Criteria for Buildings and Other Structures Wind (House) Project: Wind Load Parameters - Envelope Method Exposure B Sec.26.7 Risk Category II Table 1.5-1 Mean Roof Height (ft) 21.25 Roof Slope X/12 6 Roof Angle (deg) 26.57 a (ft) 5.525 Figure 28.3-1 Note "a" Kd 0.85 Table 26.6-1 K,t 1 V (mph) 97 K, 0.70 Table 26.10-1 qh (psf) 14.33 Eq. 26.10-1 Minimum Wind Pressure on Walls (psf) 16 Minimum Wind Pressure Sec. 28.3.4 I Level Length Along Ridge Length Perpendicular to Roof trib (ft) Wall trib (ft) I (Parallel) (ft) Ridge (ft) Roof 64.75 55.25 8 0 long short Perpendicular to Ridge Parallel to Ridge Roof Roof Roof Area (sf) 429.6 Roof Area (sf) 353.6 Roof Area (corners, sf) 88.4 Roof Area (corners, sf) 88.4 Wall Area (sf) 0 Wall Area (sf) 0 Wall Area (corners, sf) 0 Wall Area (corners, sf) 0 Roof Wind Shear k 5.57 Roof Wind Shear k 4.81 Check Minimum Pressure Calculated Calculated Parallel Minimum Ultimate Minimum Parallel Level Perpendicular Pressure (psf) Pressure (psf) Perpendicular Shear (k) Ultimate Shear (k) Roof 10.74 10.89 4.14 3.54 Summary Table Level Perpendicular Wind Parallel Wind Shear Perpendicular Wind Parallel Wind Shear Shear (ultimate, k) (ultimate, k) Shear (allowable, k) (allowable, k) Roof 5.57 4.81 3.34 2.89 Base Shear 5.57 4.81 3.34 2.89 All references are from ASCE 7-16: Minimum Design Loads and Associated Criteria for Buildings and Other Structures Wind (Garage) Project: Wind Load Parameters - Envelope Method Exposure B Sec.26.7 Risk Category II Table 1.5-1 Mean Roof Height (ft) 15 Roof Slope X/12 4 Roof Angle (deg) 18.43 a (ft) 3 Figure 28.3-1 Note "a" Kd 0.85 Table 26.6-1 K,t 1 V (mph) 97 K, 0.70 Table 26.10-1 qh (psf) 14.33 Eq. 26.10-1 Minimum Wind Pressure on Walls (psf) 16 Minimum Wind Pressure Sec. 28.3.4 I Level Length Along Ridge Length Perpendicular to Roof trib (ft) Wall trib (ft) I (Parallel) (ft) Ridge (ft) Roof 28.25 26.33 10 0 long short Perpendicular to Ridge Parallel to Ridge Roof Roof Roof Area (sf) 222.5 Roof Area (sf) 203.3 Roof Area (corners, sf) 60 Roof Area (corners, sf) 60 Wall Area (sf) 0 Wall Area (sf) 0 Wall Area (corners, sf) 0 Wall Area (corners, sf) 0 Roof Wind Shear k 3.09 Roof Wind Shear k 2.90 Check Minimum Pressure Calculated Calculated Parallel Minimum Ultimate Minimum Parallel Level Perpendicular Pressure (psf) Pressure (psf) Perpendicular Shear (k) Ultimate Shear (k) Roof 10.95 11.03 2.26 2.11 Summary Table Level Perpendicular Wind Parallel Wind Shear Perpendicular Wind Parallel Wind Shear Shear (ultimate, k) (ultimate, k) Shear (allowable, k) (allowable, k) Roof 3.09 2.90 1.86 1.74 Base Shear 3.09 2.90 1.86 1.74 All references are from ASCE 7-16: Minimum Design Loads and Associated Criteria for Buildings and Other Structures WL-MASTER (House 11 Total Wall Line Level Lengths (ft) Seismic Forces (k) Wind Forces (k) Story Heights (ft) Roof 13.83 4.16 1.5028 8 Max H/W Ratios 3.5 ROOF Select strap or hold.., Length (k) H/W Ratio Increases Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning M Shear Wall Holdown Seismic Shear(pIQ Wind Shear(pIQ Wall (lb) Floor (lb) 3.1 2.29 1.04 312 109 41, 35 2.21 0.]3 SW2 HOU4 5.33 5 1.50 1.60 1.00 1.00 301 109 301 109 640 53 600 50 2.20 2.21 0.66 0.67 SW2 SW2 HDU2 HDU2 Holdown Line ' Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 ' Per Table 4.3.4 ANSI/AWC SDPWS-2015 WL-MASTER (House 21 Total Wall Line Level Lengths (ft) Seismic Forces (k) Wind Forces (k) Story Heights (ft) Roof 35.42 1.864 0.67337 8 Max H/W Ratios 3.5 ROOF Select strap or holdown Length (k) H/W Ratio Increase s Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Shear Wall Holdown Seismic Shear (pIQ Wind Shear (pIQ Wall (lb) Floor (lb) 5.75 1.39 1.00 53 19 690 58 0.20 -0.07 5W1 No Haldawn Required 13.67 0.59 1.00 53 19 1640 137 -0.11 -0.38 SWI No Haldawn Required 5 1.60 1.00 53 19 600 50 0.23 -0.04 SWI No Haldawn Required 6.5 1.23 1.00 53 19 780 65 0.17 -0.10 SWI No Haldawn Required 4.5 1.78 1.00 53 19 540 45 0.25 -0.02 SWI No Haldawn Required Holdown Line ' Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 ' Per Table 4.3.4 ANSI/AWC SDPWS-2015 WL-MASTER (A House) Level Total Wall Line Seismic Forces (k) Wind Forces (k) Story Heights (ft) Lengths (ft) Roof 26.67 4 1.67 g Max H/W Ratio 3.6 ROOF Select strap or holdown Length (k) X/W Ratio Increases Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Shear Wall Xoldown Seismic Shear Wind Shear(pIQ Wall (lb) Floor (lb) 26.67 0.30 1.00 150 63 3200 267 0.16 -0.54 1 5W1 NO Holdown Required Holdown Line ' Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 ' Per Table 4.3.4 ANSI/AWC SDPWS-2015 WL-MASTER (B House) Total Wall Line Level Lengths (ft) Seismic Forces (k) Wind Forces (k) Story Heights (ft) Roof 9308 4 1.67 8 Max H/W Ratios 3.6 ROOF Select strap or holdown Length (k) X/W Ratio Increases Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Shear Wall Xoldown Seismic Shear(pIQ Wind Shear(pIQ Wall (lb) Floor(lb) 4308 1.70 1.00 412 1]2 565 47 3.11 1.19 SW3 HDU4 5 1.60 1.00 412 1]2 600 50 3.30 1.18 SW3 HDU4 Holdown Line 'Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 ' Per Table 4.3.4 ANSI/AWC SDPWS-2015 WL-MASTER (1 Garage) Total Wall Line Level Lengths (ft) Seismic Forces (k) Wind Forces (k) Story Heights (ft) Roof 16 1.15 0.93 10 Max H/W Ratios 3.5 ROOF Select strap or holdown Length (k) X/W Ratio Increases Force in Wall Elements Seismic Shear(pIQ Wind Shear(pIQ Dead Loads Wall(Ib) Floor (lb) Seismic Overturning (k) Wind Overturning (k) Shear Wall Xoldown 6 1.61 1.00 ]2 5R 900 60 0.43 0.29 SWl NO Haldawn Required 10 1.00 1.00 ]2 58 1500 100 0.24 0.10 SWl NO Haldawn Required Hold— Line 'Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 ' Per Table 4.3.4 ANSI/AWC SDPWS-2015 WL-MASTER (2 Garage) Total Wall Line Level Lengths (ft) Seismic Forces (k) Wind Forces (k) Story Heights (ft) Roof 20 1.15 0.93 10 Max H/W Ratios 3.5 ROOF Select strap or holdown Length (k) X/W Ratio Increases Force in Wall Elements Seismic Shear(pIQ Wind Shear(pIQ Dead Loads Wall(Ib) Floor (lb) Seismic Overturning (k) Wind Overturning (k) Shear Wall Xoldown 10 1.00 1.00 58 47 1500 100 0.30 -0.01 SWl NO Haldawn Required 10 1.00 1.00 58 47 1500 100 0.30 -0.01 SWl NO Haldawn Required Hold— Line 'Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 ' Per Table 4.3.4 ANSI/AWC SDPWS-2015 WL-MASTER (A Game) Total Wall Line Level Lengths (ft) Seismic Forces (k) Wind Forces (k) Story Heights (ft) Roof 8 1.15 0.87 10 Max H/W Ratios 3.5 ROOF Select strap or holdown Length (k) H/W Ratio Increases Force in Wall Elements Seismic Shear(pIQ Wind Shear(pIQ Dead Loads Seismic Overturning (k) Wind Overturning (k) Wall(Ib) Floor (lb) Shear Wall Holdown 4 1.51 1.0] 153 109 600 40 1.11 0.90 s" HDD2 4 2.50 1.01, 153 109 600 40 1.25 0.90 SWl HDU2 Hold— Line ' Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 ' Per Table 4.3.4 ANSI/AWC SDPWS-2015 WL-MASTER (B Garage) Level Total Wall Line Seismic Forces (k) Wind Forces (k) Story Heights (ft) Lengths (ft) Roof 24 1.15 0.87 10 Max H/W Ratio 3.5 ROOF Select strap or holdown Length (k) X/W Ratio Increases Force in Wall Elements Dead Loads Seismic Overturning (k) Wind Overturning (k) Shear Wall Xoldown Seismic Shear(pIQ Wind Shear(pIQ Wall(Ib) Floor (lb) 24 0.42 1.00 48 36 3600 240 -0.67 -0.79 1 5W1 NO Holdown Required Holdown Line ' Increase per 4.3.4.2 ANSI/AWC SDPWS-2015 ' Per Table 4.3.4 ANSI/AWC SDPWS-2015