REV3 APPROVED BLD BLD2023-0027+Architectural_Plan+8.8.2023_5.51.37_PM+3714668COVERAGE GARAGE 588 EXISTING HOME 1036 DEMO 319 ADDITION 949 WINDOW SEAT 14 TOTAL 2906 ----------------------------------------------- DEMO 319 ADDITION 949 WINDOW SEAT 14 TOTAL NEW CONDITIONED 1282 DRIVEWAYS 367 ROOFS W/ OVERHANGS 3170 HARD SURFACING 659 TOTAL IMPERVIOUS SURFACES 4196 EXISTING IMPERVIOUS SURFACES HOUSE ROOF 1485 GARAGE ROOF 711 HARD SURFACES 514 DRIVEWAYS 858 TOTAL EXISTING IMPERVIOUS SURFACES 3568 ADDED IMPERVIOUS SURFACES = 4196-3568 = 628 SF TOTAL NEW & REPLACED IMPERV SURF = 1353 SF TOTAL IMPERVIOUS TOTAL LOT COVERAGE: 2848 SF Type of area Square footage Stormwater facility Driveway no new or replaced area New dry well to be used for replaced 261 sf and new 949 sf of roof area. Existing splashblocks to be used for existing roof areas. Roofs w/ Overhangs 1353 sf Hard Surfaces no new or replaced area X% Retrofit n.a. 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2IC " 14 GA -\ WIRE FABREQUAL /\\ 0 N NATIVE BACKFILL MATERIAL J 8„ FILTER FABRIC MATERIAL IN CONTINOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE 2" x 2" WOOD/STEEL POSTS-\ WIRE MESH FENCE `TO SUPPORT FILTER FABRIC N \- BURY BOTTOM OF FILTER I N K-1.I1I R" TI 11" TOTAL ROOF AREA w/ OVERHANGS 3170 SF NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. CITY INSPECTION REQUIRED ON 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ALL EROSION CONTROL METHODS ACTIVITY. BEFORE OTHER WORK CAN BEGIN REVISION DATE FILTER FABRIC FENCE JANUARY 2018 CITY OF EDMONDS FILTRATION SYSTEMS CITY OF EDMONDS PUBLIC WORKS STANDARD T PUBLIC WORKS DEPARTMENT DETAIL DEPARTMENT rlqw APPROVED BY: R. ENGLISH E R- 9 0 0 DRIVEWAY 150 sf EXISTING GARAGE 588 SF ADDITION ALL NEW CONSTRUCTION 949 SF Demolished Area ALL NEW Hard Surface CONSTRUCTION 338 sf 319 SF EXISTING HOME 1036 SF Hard Surface 69 sf AREA PLAN 1" = 10'-0" /O O 0 DO 00 O O O O O . \}FILTER SOCK WITH OVER FLOW HOLES (TYP) Q a 8 ■ TOTAL NEW & REPLACED IMPERV. SURF. - 1'I SF Hard )urfacE 252 sf DRIVEWAY 217 sf GRATE FILTER SOCK WITH OVER FLOW HOLES (n'P) `CATCH BASIN \ NOTES: `CATCH BASIN 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL. 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. REVISION DATE TEMPORARY JANUARY 2018 SEDIMENT TRAP FOR CATCH BASINS STANDARD D ETAI L APPROVED BY: R. ENGLISH E R- 9 0 2 Alterations Worksheet - 2018 Washington State Energy Code Project Information Contact Information Hill addition & remodel Linda Mackin 633 Alder LKMackin@gmail.com Edmonds, WA The WSEC requirements for alterations are located in Chapter 5 of the code text. Alterations (remodels) do not need to obtain energy credits from Table R406.3 Additions must meet the requirements for new construction. This includes nonconditioned space being ENERGY NOTES: altered to become conditioned space. Will the wall cavities be exposed? F_ n Addition to comply with 2018 Washington Energy p y g Yes No code If yes: Exposed wall cavities must be insulated - 2 X4 wall studs require R-15 insulation Energy code compliance is per SEC R402.1.1 - 2 X 6 wall studs require R-21 insulation Prescriptive Will the roof/ceiling framing cavities or attic be exposed? ll"] Yes C No An Insulation Certificate for Residential If yes: Exposed roof/ceiling assemblies must be insulated - Construction shall be posted wlthing 3' of the Vaulted ceilings: Insulate to the full depth of the framing member electrical panel prior to final inspection while allowing for the minimum 1"ventilated space Air leakage shall not exceed 5 air changes/hour and Flat ceilings: Install R-49 insulation or what the attic space can shall be tested and certified prior to final inspection accommodate based on the roof pitch A minimum of 75% of lamps in lighting fixtures shall Will the floor framing cavities be exposed? ❑ Yes n No be high efficacy lamps If yes: Exposed floor cavities must be insulated to R-30 New windows and doors in remodeled areas to Are the windows and/or doors being replaced? Ev] Yes E: No have max U factor of 0.30. (includes both window or door and frames) Where framing is exposed in remodeled areas R If yes: New windows and doors must have an area weighted average U-factor of <_0.30 values to be min. Will the heating or cooling system be replaced? F Yes F_ No R-15 @ 2x4 stud walls If yes: New equipment must meet current requirements and R-30 @ floors ducts need to be tested R-10 continuous & 2' depth @ slab on grade R-49 @ ceiling or depth Of roof joists Will the hot water system be altered? n Yes F_ No If yes: New water heating equipment must meet current code requirements 1224 sf addition Are more than 50% of the light fixtures being changed? i I Yes N� � Small dwelling unit = 3 credits: Heating option 2: heat pump = 1.0 If yes: 90°/D of all lamps must be high efficacy Option 5.5: heat pump water heater = 2.0 (LED or CFL) , QELECTRICAL - OVERHEAD G GAS ALLEY 76.13' 15' rear setback --------------- --- I I I I I I I I I I I I I I I I I I I I I I I \ \ Rem men I gar door \ eo°OVe I \ I I IL-- - \I------ JI-=-__-----------� sidewalk' O I I , 4,25" Smoke R[m'k-__------ 1 / 14�.2" oe a1n ' __ -_-_--------------------------- ___ Rem ve Porti°n °f tlrlveway / REMOVE ENTIRE ORiHIA noolTION o / i -� -� I ----------r--------- '-Rem re r° , Wamove eras M1. G PPmI ,.. r ==== y waa^e aI1::: \ / ar----_ } Y ( 1 enSeBe aemP.e \ / a e ndryrl°set. \7. Ram tee' N ' 8a5 \ / opening. W �xf'ures �H N _0 n \I/ I ------------ Rem ve l°w--`�------------------ J � f + -walk& Re 'i Remove window - i tllvitling wall. / \\ windows. I Replace \ \ Repdows. '1 O I wmdPw: L--------- - - - ----- r---------- -- a 11erry J ro be preserved 0 s, irPn�.role 20' front s tback - - S S SEWER 76.13' ALDER STREET WATER V l water D meter I CB RIM=103.48 IE 12" PVC (N)=98.76 CB RIM=103.48 SO E12"PVC (5)=98.68 IE 12" PVC(N)=98. 6 t IE 12 PVC(S)=98, 8 SD SD SD SD SD SD --------5----------------------ss--------------- SS ALDER STREET SO SD SDI SS SSMH RIM = 106.65 IE 8" PVC (E) = 96.38 IE 8" PVC (W) = 96.28 SSMH RIM- 106.65 IE 8" PVC(E)=96.38 IE g99 PVC(W)=96.28 2018 Washington.State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington PW Single Family- New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: 6 credits All dwelling units that are not included in #1 or #3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1S credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R406.2 and 406.3 Pleating Credits - select ONE Fuel Normalisation Descriptions User Notes Options heating option 1 Combustion heating minimum NAECA4 0.0 ❑ 2 Heat pump` 1.0 0 3 Electric resistance heat only - furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 5 All other heating systems -1.0 ❑ Credits - select ONE Energy ❑ lions p Energy Credit Option descriptions energy option from each category Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier III of NEEA's advanced water heating specification or For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of5.5 2 Q NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. s Energy Options Summary of Table Energy Credit Option Descriptions (cunt.) Efficient Water Heating Efficient Water Heating Efficient Water Heating R406.2 (cant.) Credits - select ONE energy option from User Notes each categoryd 0.5 ❑ 5.1a 5.2 0.5 ❑ 5.3 1.0 ❑ 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating Efficient Water Heating 2.0 2.5 0 5.6 ❑ 6,1, Renewable Electric Energy (3 credits max) 1.0 0 ❑ 7.1 lApplianCe Package 0.5 Total Credits alculate Total Clear Form 0 U to N W Ln I o' I I I EXISTING - SITE PLAN 111 = 10'-011 ELECTRICAL - OVERHEAD \ 0 0`'', ALLEY 76.13' S 00 I.L GRADE + ' FILTER FENCE SEE I ' - ELEV w15'`Irear,setblack ­\ �' 104.5' ER-900 H� / y VEGETATED GV `DE- FLOWPATH ELEV w 4/ w ,' ' I- + TEMPORARYSTOCKPILE i - w COVER WITHIN 24 HOURS ✓ SITE DATA w w ADDRESS: 633 Alder, Edmonds, WA ;B PARCEL # 00434209502800 ZONING: RS-6 LOT SIZE: 8239 SF (per (p survey) ' /'4s" diam. x 3' a II I I deep drywell w/ PROJECT SCOPE: drainage rock& filter fabric REMOVE PREVIOUS 319 SF ADDITION / p`O REMODEL 64 SF INTERIOR , ALL DISTURBED AREAS TO BE cm k ADDITION OF 949 SF INCLUDING 1 ADDITIONAL BEDROOM & COMPOST AMENDED PER 2014 SWMMWW BMP T.5.13 71-411 BATHROOM, RELOCATION OF LAUNDRY & MASTER SUITE, _ ADDITION OF MUDROOM. ADDITION OF WINDOW SEAT. INSTALLAND CATCH BASIN SEE if IF ----------�-I REPLACEMENT OF EXISTING WINDOWS THROUGHOUT. TESC MEASURINSALL ER 902 ACCORDING TO IrB EXISTING MAIN LEVEL: 1297 APPROVED PLANS, EXISTING GARAGE: 588 SF CITY O EXISTING LOT COVERAGE: 1885 SF STAND RDMONDS AILs' ANDALL ROTHER PROTECT TREES MEASURES THAT MAY w/ LIMIT OF PROPOSED MAIN LEVEL: 2260 sf i BE REQUIRED DURING CONSTRUCTION PROPOSED GARAGE: 588 SF CONSTRUCTION. FENCING - -------------- PROPOSED LOT COVERAGE: 2848 SF = 34.6 % TREES IN ALLOWED LOT COVERAGE 35% = 8239 x 0.35 = 2883.65 SF BACKYARD TO BE M TOTAL PROPOSED IMPERVIOUS SURFACE: 4196 SF EXISTING IMPERVIOUS SURFACE: 3568 SF RETAINED � I N NEW IMPERVIOUS SURFACE = 628 SF ` \ PROPOSED PARKING SPACES: 3 REQUIRED PARKING SPACES: 2 Q Lrl m I I I I; 5 -2" HEIGHT CALCS: A=+102.8' / B=+104.5' .� C=+105' D=+107.8' FOC ling TOTAL=+420.1' I -' " I drain pert AVERAGE GRADE = 420.1/4=105.025 - - - - - _ _ - - ' I pip hoL around se. I SEWER SEW R I Tie in to PROPOSED MAXIMUM HEIGHT: 123.935' ALLOWED MAXIMUM HEIGHT: 130.025' CLEANOUT -� -� -CLEAN UT I I l soli I ling d footing sP1asM18 dr cat Into h basin t LI°<k / /i �- -- -_ f 1 II I Iv II \\ WHOLE L 104 r a \ / \ \ HOUSE 0 Y \ EXHAUST 00 m N U FAN 65 CFM w/ OJ INTERMITTENT -0 a)\ / \ OFF/ON to CONTROLS Ln / \ \ 121- 11 _ existing / � r-I NOTE: bl- MIN 3' \ 0 HORIZONTAL---_ SEPARATION&1' --. GRADE _-_..--------- I ELEV ----- y-- ------------ -' GRADE SEPARATION IS 105' ---- ---- J ct ELEV REQUIRED 107.8' BETWEEN DRY - - UTILITIES AND' -SEWER, WATER PROTECTTREES PV\bVERTICAL AND STORM AND h w/LIMIT OF5'FROM ANY CITYMAINLINES U I /CONSTRUCTION' O FENCING s I � I I o 0 � fr nt s t ack S S SEWER 76. 3' ALDER STREET EXISTING SIDE SEWER LOCATION / WATER - CONNECTION TO r ^ REMAIN v 1 water meter I CBRIM=103.48 IE 12" PVC (N) = 98.76 CB RIM=103.48 S IE 12" PVC (5) = 98.68 IE 12 PVC(S)=98. 8 SO SD SD 55 : The following documentation shall be available on site for the building inspector: ■ SITE DATA ; QCOE APPROVED ARCHITECTIJ&/ ePLAk T/2023 ADDRESS: 633 Alder, Edmonds, WA ! ❑x COE APPROVED STRUCTURAL PLAN SET PARCEL # 00434209502800 ; ❑x COE REVIEWED CALCULATION PACKET ZONING: RS-6 : ❑ ENERGY CREDIT WORKSHEET SITE PLAN CIVIL PLAN LOT SIZE: 8239 SF (per survey) ! ® Calculation page dated 4/25/ 023 Calculation revision dated 8/09/20� PROJECTSCOPE: 'LJ REMOVE PREVIOUS 319 SF ADDITION CITY OF EDMONDS BUILDING DEPARTMENT 2021 '---------------------- REMODEL 64 SF INTERIOR ADDITION OF 949 SF INCLUDING 1 ADDITIONAL BEDROOM & BATHROOM, RELOCATION OF LAUNDRY & MASTER SUITE, ADDITION OF MUDROOM. ADDITION OF WINDOW SEAT. REPLACEMENT OF EXISTING WINDOWS THROUGHOUT. Please obtain a separate Plumbing permit Cease from EXISTING MAIN LEVEL: 1297 Cit of Edmonds ■ EXISTING GARAGE: 588 SF %10 0 0�■�■�■�■�■� EXISTING LOT COVERAGE: 1885 SF dM0 0 0-'-'-'-'-'-' IAs stated above "following documental on shall be available"please provide origin all plan . PROPOSED MAIN LEVEL: 2260 sf set that is dated on 6/05/2023 PROPOSED GARAGE: 588 SF PROPOSED LOT COVERAGE: 2848 SF = 34.6 % ALLOWED LOT COVERAGE 35% = 8239 x 0.35 = 2883.65 SF TOTAL PROPOSED IMPERVIOUS SURFACE: 4196 SF EXISTING IMPERVIOUS SURFACE: 3568 SF NEW IMPERVIOUS SURFACE = 628 SF PROPOSED PARKING SPACES: 3 REQUIRED PARKING SPACES: 2 HEIGHT CALCS: A=+102.8' B=+104.5' C=+105' D=+107.8' TOTAL=+420.1' AVERAGE GRADE = 420.1/4=105.025 PROPOSED MAXIMUM HEIGHT: 123.935' ALLOWED MAXIMUM HEIGHT: 130.025' ALDER STREET SD SD SD SD 5° SD SS --- SS------------ ------------_____- SS S - - - ------------- ---- - -- -- - ---- -- ---- -- -- - -- -- -- SSMH RIM = 106.65 IE 8" PVC (E) = 96.38 IE 8" PVC (W) = 96.28 DATUM POINT. SSMH RIM=106.65 SEWER MANHOLE IE g" PVC(E)=96.38 RIM = + 106.65' IE g" PVC(W)=96.28 PROPOSED -SITE PLAN 111 = 10'-011 Drawings and the associated cad files are considered 'instruments of service' and may nc be used for any other project or for any addition to this project or for completion of drawings by others. All rights reserved. APPROVED LA MUST BE 01� OB SITE LLVNV RK SUBJECT TO FIELD IN P CTION FOR OD OMPLIANCE REVISED CI OF EDMONDS PI.Ah E APPROVED UILDING DIVISION OFFICIAL 2023 DATE BJILDIII Aug22 APPROVED ■ GENERAL NOTES GOVERNING BUILDING CODES: ■ ALL CONSTRUCTION SHALL COMPLY WITH LOCALLY ADOPTED BUILDING CODES AND AMENDMENTS. CONTACT CITY FOR GOVERNING UNIFORM BUILDING CODE, UNIFORM PLUMBING CODE, UNIFORM MECHANICAL CODE, UNIFORM ELECTRICAL CODE AND UNIFORM FIRE CODE. ALL PRODUCTS SHALL BE INSTALLED PER 2018 IRC AND ICC AND MANUFACTURERS' WRITTEN INSTRUCTIONS. PRODUCT SUBSTITUTIONS FOR PRODUCTS LISTED SHALL ALSO HAVE 2015 IRC AND ICC APPROVED EVALUATION REPORTS OR BE APPROVED AND LISTED BY OTHER NATIONALLY RECOGNIZED TESTING AGENCIES ALL LUMBER MUST BEAR AN APPROVED GRADING STAMP AND BE NOT LESS THAN GRADE SHOWN ON DWGS ALL PLYWOOD USED IN EXTERIOR LOCATIONS SHALL BE EXTERIOR GRADE ■ ALL STEEL MUST BE ASTM AS SPECIFIED ON DRAWINGS EXTERIOR PAINT TO BE SHERWIN WILLIAMS SUPERPAINT OR EQUAL APPLIED ACCORDING TO MANUFACTURERS INSTRUCTIONS FOUNDATIONS SUPPORTING WOOD SHALL EXTEND AT LEAST 8" ABOVE ADJACENT FINISH GRADE CONSTRUCTION SHALL CONFORM TO INT. FIRE CODE. APPROVED CARBON MONOXIDE ALARM REQID OUTSIDE OF EACH SLEEPING AREA PROVIDE SPARK ARRESTORS @ ALL FIREPLACES AS REQ'D BY CITY ORDINANCE PROVIDE FIRE SPRINKLER SYSTEM AS REQ'D BY LOCAL ORDINANCE MISC. SITE STRUCTURES, SWIMMING POOLS, SPAS, FENCES, SITE WALLS (INCLUDING RETAINING WALLS) AND GAS STORAGE TANKS REQUIRE SEPARATE PERMITS ALL EXITS TO BE OPENABLE FROM THE INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE SHEET INDEX: BLD2023-0027 - REV3 - INSULATION AND FOOTINGS A-1: SITE PLANS, GENERAL NOTES, ENERGY NOTES A-2: DEMOLITION PLAN, PROPOSED PLAN A-3: EXISTING EXTERIOR ELEVATIONS A-4: PROPOSED EXTERIOR ELEVATIONS A-S: BUILDING SECTIONS, WALL SECTIONS, DETAILS A-6: WALL SECTIONS, WALL SECTION MAP S1: STRUCTURAL NOTES S2: FOUNDATION & ROOF FRAMING PLANS S3: STRUCTURAL DETAILS REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT o e� � � o S N'z z H 0 � w a � z 3U 0 4 x � C W a o F Lo 0 wLo N 00 � I­_C00 = 0 N Z Q s � U LLJ 6 _7zs Lu a cn Zp w s J DATE PLOTTED 8/4/2023 SCALE varies FILE NAME Hill plan c SHEET A-1 ALLEY 76.13' ALLEY 76.13' 15' rear setback 15' rear setback A I I I I I I I I I II I I I II I I I I I I I I I I I I I I I I I I I I I I _______________________________________________________________ w I GF I I N W I I I I o� I GARAGE I Electric Vehicle Parking: / Existing outlets, lights, switches to level 2 oFully r level 31EV I remain. charging receptacle I outlet including conduit To existing & wiring & capacity I garag Its req'd to allow for installation of EV charging station. Remove I wP I I garage doorFCI i , G I Ne I ea Remove man ' �I pump _ door I ew 368 I minl. 9.5 I HSPF I ex erior \ door II i I ` -�7'~ 220V. 48AEV Existing elect. WP GFCI arger I Close off existing garage door and man door. � I , ______________ L. _______________ _ - - ----- pane _ o = _ — — _ 771 Lri�� I ' ELECTRICAL LEGEND s New 3680 B Hydrid HP AUND W tier M U D R00 M New - - - - - - - WALL SWITCH A-5 A-5 nn exterior door - slab ins +0" 3 2 3'-5' 9 xh 3 -5 rn _ 12'-3" 1/4 I' terior E rn OP & �LK = or _ - ' C SWITCH WITH DIMMER f n 3Q' TO IF DR VEWAY Remove DIM 10, minSOcfm C portion of sidewalk �� i ; {} CEILING LIGHT) -BOX TYPETBD �° � as seen Cn w � Ln f zo f i oo FAN/LIGHT COMBO `r' ? -i o o High in storage _ 6 Field o +0" _ - - - - - - - - - �o _5 verify. - gfci Exhaust fan �I WALL LIGHT FIXTURE G x UP 4 shelving) v m Garage & house \ CEILING LIGHT- PENDANT A-5 to 5 min 50 above H & of not EXISTING CEILING HEAT LAMP - ON TIMER staff O o p`-5 30 pkt Wsr/Dryer - u, O' m rn perfectly parallel. WATERPROOF EXHAUST FAN �' A-4 m handrail ?: ^ +33" Ln +42" 3 & Demolition[Ell exh EXHAUST FAN NO LIGHT v 11 gfci 10'Iroof fan �' 3'-10" w ter r tubul r cas d - skylit M O.H. ope ing J _ - Remove stairs r 1 14 -2 CEILING FAN - LIGHT TBD m PROPOSED FLOOR PLAN ' b h 1 �1-------- ra = linen VAULT I I G all -----+—_; --------------------7------------------- ---� D ID Ln closet C gfci Ln D T----- --------------------11 ------------------ DUPLEX OUTLET- STD. BASEBOARD HEIGHT BEDRM 1 I - - - - - _ = 1 = - - - - - - - - - - - - - - - - - = 1 III I � \ u rr-------- 30" b f. B VAULT CEILING G DUPLEX OUTLET- GROUND FAULT CIRCUIT INTERUPT = Remove portion of driveway - III II 111 III III 11 111 III I � WP DUPLEX OUTLET- WEATHERPROOF (,OkD,5 �, UI 3' S' 5'-5" 1 REMOVE ENTIRE "11 Qla II NORTHEAST I_d lu II ADDITION 11; +42" g DUPLEX OUTLET -SPECIFIED DISTANCE ABOVE FIN. FLR. wall _ w> „ 5 - 30 pkt c wP II II 1u DUPLEX OUTLET IN FLOOR n GF� lu a II I1u II ` FLR m .� I 1 closet .. -------- Ili D/cot SMOKE &CO2DETECTOR - HARD WIRED &INTERCONNECTED VAULT CEILING I I o1 BEDRM 1 - "' a--' I; o1 ------- UNDER CABINET LIGHT under cab It �' N 01 _ - 1 I11 O NETWORK CONNECTION O 1 L BEDRM 4 I q I I WALL PLATE CO-AX CABLE OUTLET 48" bi fold FLAT CEILING 111 III co-ax Lri ql III I 111 III - attic WALL PLATE USB OUTLET 1D _ 5 access 5" Ili = �_-____ - - - - - - - - �l III II II USB "' wP GFC 3'-1011 31 311 511i 2'-1" 511 2'-7"i 12'-10" pw� - L5 r ' III II II II I III II II I � I C I III II II I I I IL New New Lri built-i r helvi -- r�_______, - - - - II Wholehousemechanical ventilation system per M1505.4le 3080 tfan - 0 min o minsoc A-5 II , II ,I consisting of one or more r`/ fV � 5 e r A-5 Replace „ �� ________= III II II I I � II, rC------ /� exhaust fans, or an ERV HRV integral fans, � _ � tem ered f d p in II -,, 1' I I I I with g associated _ - _ \ \ / - -- - - -- - 1 -II-- - --' L_ ducts and controls. tubul Replace windows. - o o -------$-----==i_�` v Whole -house Exhaust fans. 2 double hung 2848 o sk li a Exha stfa y w II X \v T Remove ;` - - -� Exhaust fans required shall be replacement windows field verify - -' X ex. W O [:1 -' min 5 cf - bath 2 ^' TZQ - Remove walls & - - - - - \ fixtures@ / ducted direct) to the outside. v Exhaust air outlets shall be - ` tubular Ilte ��ab. reryainJExstingoutlets,lights, KITCHEN \ switches to remain. TCEILING _ - -- closet. '� I � _______I � master bath. I / designed to limit the pressure � sk � Exhaust fan Remove portion of p +\ Vrt ` ------� F _ ----- \ - -- - I' r -1 to the outside and backdraft o to cl min to 100cfm c rn - \ +42" gfci buil i n CIOSet she) ing west wall - - - - - ) L__ , �/ 10 ,I 1� III II II 1--. U equipped with dampers or motorized dampers p P 0 z OFFICE FLEX SPACE 2 2 -6 1-9 +4z" \ 8 bi- ass p U for new window. Replace --+\-�--------------------------------\ °------- __ ==so=-==----------- -*--.- o � - - ° ° - m / \ -/ i - - -- / I c / L J s� In accordance with the Washington State Ener Code. g Energy - 104 sf T�_� _ VIP N ------- - --- --------- I , _ / 2'-3" 2'-5" 5 1'-6" -7" 5' `V FLAT CEILING `r' north \ / - - - - ,I r�', 11 / _ _ J � The system shall be designed Y g and installed to exhaust and/or `° �'-10" �I I I 1 / \ = n BEDRM 3 �, window. ` - - - - - - - - - - - - - J 1 y \ L - - -J 1_ _ &- - - -- -_ ---_ _ _ _ = E supply 65 cfm. The whole house w z Existingoutlets, lights, switches to +42" +42" - J \ _ _ _ _ _ _ _ _ -_ _ _ _ _ _ W G C Z = J - ;U u 1 l i 1 ,_ u'I / \ �_ (, ventilation system shall be ('6 configured with intermittent off E remain. N \ - - - - - - - - - - - - +48" couter \ \ I, _ _ _ _ _ - � I I 1 I I 1 ILL �� �' I I 1 - - -f J Q) controls per Section M1505.4.3.2. Design \ To/existing I hts Increase _ \ " \ /enlarge Remove` - - and � installation of the system or \ io ,, cased �n \ Ln _ o \ / laundry closet. \ Remove cased • — be in m \ / o enin to p g Egs outlets, g �N _ . e,'1,1 opening. \ / ,walls & �i equi ment shall carried out p L) 42 wide ants, witcnesto \ remain. w o �cr N gas II \ / �V fixtures @ _ accordance with manufacturers F ga in / FLAT bath 3 3w rn _ \ / - - - - - - both. _ _ _ _ _ installation instructions. Whole Q� house fans b \ / NO CHANG FL Lr) Ln u \ / ventilation shall e rated for sound at a maximum of \ / New interior . 1.0 sone. The whole house i To existing \ / l i hts g so"x80' be BEDRM 2 \ supply fan shall provide ducted g outdoor ventilation air to each = o u.n.o. Remove low walls& / \ ,; BEDRM 2 Replace L 1 habitable space within the residential unit. / \ o / lights, _ Remove window II dividing wall. / \ windows. switches to r remain. � `� 10 II � III & portion of wall I / \ II -10" / \ roof I L , / \ _ _ Existingoutlets, lights, switches to 0 H. , I'I --------- L-- - LIVING ROOM remain. P 3660-D - new FCI ' / \ NO CHANGE TO / \ E O 3 '-4" 3' CHANGE 4'-5" ° o = o EXISTING WALL / EXISTING 3_� o in in "^ A-5 / \ Ln INTERIOR INSULATION OF EXISTING WALL / \ 3 N INTERIOR INSULATION c ins Replace \ Replace 8460 replacement / \ OF EXISTING WALL windows. \ windows. window field verify ;--I ®.2dou v New entry door sidelites 6481 v e ungw top mullions ° 36" x 60" windows E 5' 6' 3'-4" A EXTERIOR WALL ASSEMBLIES WILL NOT ENCROACH 20' front setback 20' front setback - - - 76.13 ALDEIII I I 76.13' ALDER STREET PROPOSED - FLOOR PLAN 1/4" = 1'-0" Drawings and the associated cad files are considered 'instruments of service' and may not be used for any other project or for any addition to this project or for completion of drawings by others. All rights reserved. REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O � =O s � � Lfi — 1: 0 F— �� w N 00 00 1:~ O N Z Q s U LLI 6 w 0 a cn w S N - = 0- J U J DATE PLOTTED 8/4/2023 SCALE varies FILE NAME Hill plan c SHEET A-2 EXISTING FRONT (SOUTH) ELEVATION EXISTING NORTH GARAGE ELEVATION L EXISTING SOUTH GARAGE ELEVATION II EXISTING NORTH ELEVATION WITHOUT GARAGE L I ------ Drawings and the associated cad files are considered 'instruments of service' and may not be used for any other project or for any addition to this project or for completion of drawings by others. All rights reserved. REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O � 0 S � -7� z C �W c� z 5 �¢�x3 C W a o � F o v Lfi — 37 o F- LU ~ N C 00 00 O N Z Q s U LLJ 6 Lu ZO a cn LLI S - —� = 0- J U J DATE PLOTTED 8/4/2023 SCALE varies FILE NAME Hill plan c SHEET EXISTING WEST ELEVATION A-3 Required handrails shall be of one of the following types or provide equivalent graspability. Type I. Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches (32 mm) and not greater than 2 inches (51 mm). If the handrail is not circular, it shall have a perimeter dimension of not less than 4 inches (102 mm) and not greater than 61/4 inches (160 mm) with a cross section of dimension of not more than 2-1/4 inches (57 mm). Edges shall have a radius of not less than 0.01 inch (0.25 mm). Type II. Handrails with a perimeter greater than 6-1/4 inches (160 mm) shall have a graspable finger recess area on both sides of the profile. The finger recess shall begin within a distance of 3/4 inch It 9 mm) measured vertically from the tallest portion of the profile and achieve a depth of not less than 5/16 inch (8 mm) within 7/8 inch (22 mm) below the widest portion of the profile. This required depth shall continue for not less than 3/8 inch (10 mm) to a level that is not less than 13/4 inches (45 mm) below the tallest portion of the profile. The width of the handrail above the recess shall be not less than 11/4 inches (32 mm) and not more than 2314 inches (70 mm). Edges shall have a radius of not less than 0.01 inch (0.25 mm) PROVIDE CONTINUOUS HANDRAIL ON AT LEAST ONE SIDE @ ALL STAIRS WITH 4 OR MORE RISERS 1%" HANDRAILS SHALL BE min CONTINOUS FROM A POINT DIRECTLY ABOVE THE TOP RISER TO A POINT DIRECTLY 4 2 O ABOVE THE LOWEST RISER m/ax THE USE OF A VOLUTE, TURNOUT OR EASING IS PERMITTED ABOVE THE LOWEST STAIR HANDRAIL ENDS SHALL BE RETURNED OR TERMINATED IN SAFETY TERMINALS HANDRAILS AND GUARD RAILS TO WITHSTAND A 200 LB CONCENTRATED LOAD APPLIED AT THE TOP OF THE RAIL MIN & MAX DIMENSIONS AS SHOWN H n D ^ ^ SEE STRUCT ENG DETAILS FOR \vl K A CONNECTIONS 1 D6 HANDRAIL SEE STAIR DETAIL FORITREADS 1 AND RISERS N 30.64' 105.64' 30.64' Maximum allowed Height = 130.64' +123.97' u,lN 130.64' Maximum allowed Height = 130.64' +123.97' MAXIMUM ACCESSORY HEIGHT N — RAISED HEEL TRUSS TOP OF PLATE - EXISTING 08'-o" FLOOR - HOUSE 00 Average grade = 105.64' N 105.64' _ FLOOR - MUDROOM J105'-2-3/4" FLOOR - GARAGE N Replacement windows NEW ENTRY DOOR & SIDELITES MAX U-VALUE 0.30 PROPOSED FRONT (SOUTH) ELEVATION Replacement windows \ T I I I I I I I I I new 3660-DH I I Eave of addition within 5' of property line to be 1 hour fire -rated 10" Eave of addition — MAXIMUM ACCESSORY HEIGHT 6:12 Eave of within 5' of existing o addition garage roof to be 1 within 5' of hour fire -rated property line to be 1 hour RAISED HEEL TRUSS fire -rated �— TOP OF PLATE - EXISTING 00 North wall @ ddition to be 1 hourfi -rated t71 L L—J new 4661-DH new 4661-DH new 4661-DH new 3660-DH new 3660-DH ew EGRESS EGRESS EGRESS EGRESS 1/4 108'� FLOOR - HOUSE ite oor Average grade = 105.64' AX N U VALUE 105 4 105'-4" FLOOR - MUDROOM 30 105' 2-3/4" FLOOR - GAR PROPOSED EAST ELEVATION 1' A Maximum allowed Height = 130.64' MAXIMUM ACCESSORY HEIGHT RAISED HEEL TRUSS TOP OF PLATE - EXISTING 108'-0 FLOOR - HOUSE Average grade = 105.64' 105'-4" FLOOR - MUDROOM 105'-2-3/4" FLOOR - GARAGF_ Ln N 30.64' +123.97' Maximum allowed Height = 130.64' existing North wall @ addition to be 1 hour fire -rated PROPOSED WEST ELEVATION ext. door 2' GAP Eave of addition within 5' of existing garage roof to be 1 hour fire -rated new 34 door MAX U-V LUE L PROPOSED NORTH GARAGE ELEVATION II L _ � II II II new new 36"x60" 36"x60" dh dh L�J r_J F J O O F _ J F_J I new new 36'x60" 36"x60" dh I dh new 36"x60" dh PROPOSED -ELEVATIONS 1/411 = 1'-011 existing 6:12 6448 do I i ble hung 6448 double hung I O Align w/ bottom eg of existing siding existing 6'-4" Drawings and the associated cad files are considered 'instruments of service' and may not be used for any other project or for any addition to this project or for completion of drawings by others. All rights reserved. REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT O � S � O � z 0 z �U� �¢�x3 C W a o � F o � Lo O I� U LU N 00 �^ ~ °O , = O V IY N Z Q s U LLJ 6 Lu a (n p w s 0— J J DATE PLOTTED 8/4/2023 SCALE varies FILE NAME Hill plan c SHEET A-4 REPLACED BY WALL SECTION F ON A-6 OF SUPPORTING A 300 LB SEE STRUCT ENG DET LOAD @ ANY POINT FOR CONNECTIONS MIN. TREAD WIDTH = 36". HANDRAILS MAY PROJECT 1-1/2" INTO WIDTH MIN. TREAD DEPTH = 10" �y MAX. TREAD HEIGHT = 7.75" PROVIDE CONTINUOUS HANDRAIL OR TERMINATE @ NEWEL POST OR SAFETY 4" TERMINAL MAX HANDRAILS AND GUARD RAILS 4° TO WITHSTAND A 200 LB MAX CONCENTRATED LOAD ° APPLIED AT THE TOP OF THE RAIL INFILL COMPONENT TO _ x WITHSTAND A 50 LB LOAD 1 APPLIED OVER A 12"X12" AREA MIN. GLASS ELEMENTS TO BE 3 4" — 1-1/4" DESIGNED WITH A SAFETY GUARDRAIL J nosing req'd for FACTOR OF 4 (per SBC REQ'D WHERE treads < 11° 2407.1.1) DECK SURFACE IS >/= +30 MIN & MAX DIMENSIONS AS ABV GRADE OR 3/8" MAX VARIATION IN SHOWN FIN FLR RISER & TREAD DIMS. STAIRS & GUARDRAILS d6stair.DWG SEE DET #1 ON A-4 FOR HANDRAIL z CUT EXISTING GARAGE ROOF OVERHANG HARDIE PANEL SIDING FLUSH WITH FACE OF SOUTH GARAGE WALL WALL SHEATHING R-21 BATT INSUL 5/8" G W B NEW HARDIE PANEL @ SOUTH FACE OF EXISTING GARAGE WALL 2x6 STUD WALL EXTEND WALL STUDS ON INTERIOR SIDE 1.75" w/ FOAM -BACKED 6" -1211 FURRING STRIPS. FILL GAPS w/ SPRAY FOAM WHERE NECESSARY. gap varies SEPARATION @ GARAGE SHOWER D8shower.DWG SEE ENGINEERING DRAWINGS FOR FRAMING SIZES AND DETAILS AND NAILING. RAISED HEEL PLATED TRUS ROOFING AIR FLOW TO CONTINUOUS RIDGE VENT ROOF SHEATHING VAPOR BARRIER �I 1 FLASHING TO BE INSTALLED IN A MANNER THAT PREVENTS l\ MOISTURE FROM ENTERING GLASS PANEL CERAMIC OR MARBLE SLAB CEMENT BACKER BOARD WALL STRUCTURE Z FLASHING ONE-PIECE READY TO TILE SHOWER PAN WITH ( inn THINSET CONCRETE FLOOR STRUCTURE NOTE: NO INSULATION @ GABLE GUTTER ENDS OF ATTIC. FURR OUT TO MATCH MIN. 2 AIR SPACE FACE OF TO RIDGE VENT SIDING. BAFFLE TO MAINTAIN AIR SPACE FIRE &EMBER SAFE 3.5x22 EAVE VENT INSTALLED PER R-49 BATT INSULATION MFR INSTR. (min.15 vents @ DO NOT COMPRESS addition) 5/8" GYP WALL BOARD WALL SHEATHING 1 HOUR FIRE RATED FIBER CEMENT BOARD. HARDIE WALL FRMG 2x6 STUDS @ 16" O.C. PANEL OR OTHER. R-21 FACED BATT INSUL LAPPED $" CEMENT FIBER SIDING FASTENED TO BATTENS ROOFING TO BE ASPHALT VERTICAL WOOD BATTENS PER HARDIE TECH SHINGLES OR METAL ROOFING NOTE #19. FASTENERS DRIVEN 2" INTO STUDS W/ WITH APPROVED FULL COVERAGE, AIR SEAL MISSED NAILS FROM UNDERLAYMENT INSIDE OF WALL WHERE POSSIBLE, REFER TO HARDIE TECH FASTENER DETAILS ON THIS PAGE. 2" MINERAL WOOL BOARD R 7 INSUL TYPICAL VAPOR RETARDER SEALED AT TOP, BOTTOM & @ HEADERS SEAMS R-10 FACED RIGID FOAM w/SEAM TAPE & INSECT BARRIERS ABOVE GRADE. DO NOT SEAL SEAMS BELOW GRADE. REPAIR TEARS IN FACING. PROTECTIVE COATING APPROVED BY RIGID INSULATION MANUFACTURER FLASHING CONTINUOUS COR-A-VENT INSECT BLOCKER OR EQUIVALENT AT BOTTOM OF BATTENS 3/4" SHEATHING & FLOOR VAPOR RETARDER UNFACED BATT INSUL R-30 Ff--INSUL. SUPPORTS @ 24" O.C. z SEE ENGR. FOR SUBFLOOR �D e PRESSURE TREATED MUDSILL SILL SEAL & CAPILLARY BREAK FOUNDATION VENT zr --� ° (see plan for size & location) d ® CONTINUOUS GLUE OR CAULK BETWEEN STEM 00 ° WALL & MUD SILL, MUD SILL & RIM, BETWEEN RIM =1 & SUBFLOOR, AT TOP OF CRAWL SPACE VAPOR BARRIER TO INTERIOR STEM. BLOCK TO SECURE VAPOR BARRIER 4 PERF. DRAIN d CLASS 1 VAPOR BARRIER TIE TO EXIST TIGHT LINE SEE ENGINEERING PLANS FOR FOOTING CRAWLSPACE VAPOR BARRIER TO BE SEALED TO SYSTEM DIMENSIONS & CONC REINFORCEMENT EXPOSED FOOTINGS & POSTS w/ MESH TAPE & MASTIC. OVERLAP 12" @ JOINTS & SEAL w/ TAPE. SEAL ALL TEARS & HOLES MADE DURING CONSTR. WALL SECTION: EXTERIOR INSULATION, 1 HOUR FIRE RATING, VAULTED CEILING, NEW CRAWLSPACE 111 = 1'-011 1" = 1'-0" 1'-0" All insulation to be installed per manufacturer's instructions Completely fill all exterior wall cavities and insulate to the full required R-Value. Exterior wall cavities are considered to be any wall separating a heated space from an unheated space. This includes but is not limited to: • Behind shower/tub enclosures on exterior walls • Where interior and exterior walls meet and at exterior corners • Stairwells to unheated basements • Skylite chases through attics Also see: WSEC Builder's Field Guide for more exterior interior wall wall framing corner intersection and insulation Do not compress insulation behind options and electrical boxes or around pipes details INSULATION D4EXTINSUL .DWG FI nOR OR CEILING FRAMING R LAUNDRY EXHAUST FAN MIN. 50 CFM ON TIMER SWITCH CA-_,. 518" GYP WALL BOARD WALL SHEATHING WALL CAP WITH DAMPER & SCREEN LOCATE WALL CAP MIN. 10' FROM ANY AIR INLET BATH OR LAUNDRY VENT RAISED HEEL PLATED TRUSS -- ROOFING ROOF SHEATHING VAPOR BARRIER FLASHING TO BE INSTALLED IN A MANNER THAT PREVENTS MOISTURE FROM ENTERING GUTTER FIRE & EMBER SAFE 3.5x22 EAVE VENT INSTALLED PER MFR INSTR. (min.15 vents @ addition) 1 HOUR FIRE RATED FIBER CEMENT BOARD. HARDIE PANEL OR OTHER. ROOFING TO BE ASPHALT SHINGLES OR METAL ROOFING WITH APPROVED UNDERLAYMENT INSULTYPICAL @ HEADERS D11exhaustfan.DWG SEE ENGINEERING DRAWINGS FOR FRAMING SIZES AND DETAILS AND NAILING. AIR FLOW TO CONTINUOUS RIDGE VENT N TS NOTE: NO INSULATION @ GABLE ENDS OF ATTIC. FURR OUT TO MATCH FACE OF SIDING. MIN. 2" AIR SPACE TO RIDGE VENT BAFFLE TO MAINTAIN AIR SPACE R-49 BATT INSULATION DO NOT COMPRESS 5/8" GYP WALL BOARD WALL SHEATHING WALL FRMG 2x6 STUDS @ 16" O.C. R-21 FACED BATT INSUL LAPPED $" CEMENT FIBER SIDING FASTENED TO BATTENS VERTICAL WOOD BATTENS PER HARDIE TECH NOTE #19. FASTENERS DRIVEN 2" INTO STUDS W/ FULL COVERAGE, AIR SEAL MISSED NAILS FROM INSIDE OF WALL WHERE POSSIBLE, REFER TO HARDIE TECH FASTENER DETAILS ON THIS PAGE. 2" MINERAL WOOL BOARD R 7 VAPOR RETARDER SEALED AT TOP, BOTTOM & SEAMS R-10 FACED RIGID FOAM w/SEAM TAPE & INSECT BARRIERS ABOVE GRADE. DO NOT SEAL SEAMS BELOW GRADE. REPAIR TEARS IN FACING. PROTECTIVE COATING APPROVED BY RIGID INSULATION MANUFACTURER FLASHING CONTINUOUS COR-A-VENT INSECT BLOCKER OR EQUIVALENT AT BOTTOM OF BATTENS 3/4" SHEATHING & FLOOR VAPOR RETARDER UNFACED BATT INSUL R-30 -INSUL. SUPPORTS @ 24" O.C. SEE ENGR. FOR SUBFLOOR --PRESSURE TREATED MUDSILL SILL SEAL & CAPILLARY BREAK FOUNDATION VENT --� ° (see plan for size & location) d d CONTINUOUS GLUE OR CAULK BETWEEN STEM 00 ° ® WALL & MUD SILL, MUD SILL & RIM, BETWEEN RIM & SUBFLOOR, AT TOP OF CRAWL SPACE VAPOR d ° BARRIER TO INTERIOR STEM. d ° BLOCK TO SECURE VAPOR BARRIER 4 PERF. DRAIN d CLASS 1 VAPOR BARRIER TIE TO EXIST TIGHT LINE SEE ENGINEERING PLANS FOR FOOTING CRAWLSPACE VAPOR BARRIER TO BE SEALED TO SYSTEM DIMENSIONS & CONC REINFORCEMENT EXPOSED FOOTINGS & POSTS w/ MESH TAPE & MASTIC. OVERLAP 12" @ JOINTS & SEAL w/ TAPE. SEAL ALL TEARS & HOLES MADE DURING CONSTR. WALL SECTION: EXTERIOR INSULATION, 1 HOUR FIRE RATING, FLAT CEILING, NEW CRAWLSPACE 111 = 1'-011 existing truss roof Cut existing garal structure to overhang flush wi remain existing existine slab on erade & footings to remain SEE A-6 FOR HARDIE / ROCKWOOL ATTACHMENT GUIDELINES RAISED HEEL PLATED TRUSS ROOFING ROOF SHEATHING VAPOR BARRIER FLASHING TO BE INSTALLED IN A MANNER THAT PREVENTS MOISTURE FROM ENTERING GUTTER INSECT PROOF EAVE VENT INSTALLED PER MFR INSTR. CONTINUOUS OR w/ CAPACITY SHOWN ON PLAN ROOFING TO BE ASPHALT SHINGLES OR METAL ROOFING WITH APPROVED UNDERLAYMENT INSUL TYPICAL @ HEADERS SEE ENGINEERING DRAWINGS FOR FRAMING SIZES AND DETAILS AND NAILING. AIR FLOW TO CONTINUOUS RIDGE VENTS NOTE: NO INSULATION @ GABLE ENDS OF ATTIC. FURR OUT TO MATCH FACE OF SIDING. MIN. 2" AIR SPACE TO RIDGE VENT BAFFLE TO MAINTAIN AIR SPACE R-49 BATT INSULATION DO NOT COMPRESS 1/2" GYP WALL BOARD WALL SHEATHING WALL FRMG 2x6 STUDS @ 16" O.C. R-21 FACED BATT INSUL LAPPED $" CEMENT FIBER SIDING FASTENED TO BATTENS VERTICAL WOOD BATTENS PER HARDIE TECH NOTE #19. FASTENERS DRIVEN 2" INTO STUDS W/ FULL COVERAGE, AIR SEAL MISSED NAILS FROM INSIDE OF WALL WHERE POSSIBLE, REFER TO HARDIE TECH FASTENER DETAILS ON THIS PAGE. 2" MINERAL WOOL BOARD R 7 VAPOR RETARDER SEALED AT TOP, BOTTOM & SEAMS R-10 FACED RIGID FOAM w/SEAM TAPE & INSECT BARRIERS ABOVE GRADE. DO NOT SEAL SEAMS BELOW GRADE. REPAIR TEARS IN FACING. PROTECTIVE COATING APPROVED BY RIGID INSULATION MANUFACTURER FLASHING CONTINUOUS COR-A-VENT INSECT BLOCKER OR EQUIVALENT AT BOTTOM OF BATTENS 3/4" SHEATHING & FLOOR VAPOR RETARDER UNFACED BATT INSUL R-30 -INSUL. SUPPORTS @ 24" O.C. SEE ENGR. FOR SUBFLOOR --PRESSURE TREATED MUDSILL SILL SEAL & CAPILLARY BREAK FOUNDATION VENT --� °D (see plan for size &location) n d CONTINUOUS GLUE OR CAULK BETWEEN STEM 00 ° ® WALL & MUD SILL, MUD SILL & RIM, BETWEEN RIM & SUBFLOOR, AT TOP OF CRAWL SPACE VAPOR d ° BARRIER TO INTERIOR STEM. d ° BLOCK TO SECURE VAPOR BARRIER 4" PERF. DRAIN d CLASS 1 VAPOR BARRIER TIE TO EXIST ° TIGHT LINE SEE ENGINEERING PLANS FOR FOOTING CRAWLSPACE VAPOR BARRIER TO BE SEALED TO SYSTEM DIMENSIONS & CONC REINFORCEMENT EXPOSED FOOTINGS & POSTS w/ MESH TAPE & MASTIC. OVERLAP 12" @ JOINTS & SEAL w/ TAPE. SEAL ALL TEARS & HOLES MADE DURING CONSTR. C WALL SECTION: EXTERIOR INSULATION, NO FIRE RATING, FLAT CEILING, NEW CRAWLSPACE 111 = 1'-011 UV IL_VIIVV JL_l� I IVI V L_L_ Eave of addition within 5' of existil garage roof to be hour fire -rated — GARAGE Eave of addition within 5' of property line to be 1 hour fire -rated PROPOSED - BUILDING SECTIONS 1/4" = 1'-0" -No h wall @ addition to e 1 hour fire -rated open shly. M D U-VALUE zo BUILDING SECTION DD BATH 1 m to Bdrm 1 BUILDING SECTION BB new 64" x 48" new window 1/4 I ite door MAX U-VALUE 0.30 N 130.64' Eave of addition within 5' of property line to be 1 hour fire -rated Maximum allowed Height = 130.64' MAXIMUM ACCESSORY HEIGHT RAISED HEEL TRUSS TOP OF PLATE - EXISTING 108'-0 FLOOR - HOUSE OP Average grade = 105.64' .64' N 105'-" 4FLOOR - MUDROOM J-105' -2-3/4" FLOOR - GARAGE �pla �ment wi Ow fief erify - existing L-_1 BUILDING SECTION CC L PROPOSED NORTH ELEVATION WITH SECTION THROUGH NEW LAUNDRY / MUDROOM TOWARD HOUSE L _ o, o - --------------------------------- High cupboard Water heater closet Floor structure Storage cupboards under floor --------------------------- ------------'- -----------'- Stairs up to window lined hall ------ ---- to bedrm 2 0 ---------- ---- ---- Drawings and the associated cad files are considered 'instruments of service' and may not be used for any other project or for any addition to this project or for completion of drawings by others. All rights reserved. REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 5 _) _7� N S � � O � z E� O E� wU42 x��x3 � w a Of H L(i � O LU N 00 1: ~ 00 0 0 N Z a s w 6 --K:s Lu Q U) Zp LU UN U IL J J DATE PLOTTED 8/4/2023 SCALE varies FILE NAME Hill plan c SHEE A-5 WALL SECTION MAP nts A A VAULT CEILING VAULT CEILING Ulu 3�a VAULT CEILING III FLAT CEILING -------2248 attic) access, tubular, skylite', FLAT CEILING I - �- ----- - -1---------------- --------- -- 104 sf FLAT CEILING I I� r — ga FLAT CEILING\ Sim ------� �-5 I I — — — — — — — t — I I I I I I I E A-6 INSUL TYPICAL @ HEADERS $FI tubular skylite ----L----- y--------------J C EXISTING EXTERIOR WALL, CEILING & ROOF STRUCTURE TO REMAIN. ADD EXTERIOR INSULATION & SIDING. WALL SHEATHING LAPPED 8" CEMENT FIBER SIDING FASTENED TO BATTENS VERTICAL WOOD BATTENS PER HARDIE TECH NOTE #19. FASTENERS DRIVEN 2" INTO STUDS W/ FULL COVERAGE, AIR SEAL MISSED NAILS FROM INSIDE OF WALL WHERE POSSIBLE, REFER TO HARDIE TECH FASTENER DETAILS ON THIS PAGE. 2" MINERAL WOOL BOARD R 7 VAPOR RETARDER SEALED AT TOP, BOTTOM & SEAMS R-10 FACED RIGID FOAM w/SEAM TAPE & INSECT BARRIERS ABOVE GRADE. REPAIR TEARS IN FACING w/ ALUMINUM TAPE. PROTECTIVE COATING APPROVED BY RIGID INSULATION MANUFACTURER FLASHING CONTINUOUS COR-A-VENT INSECT BLOCKER OR EQUIVALENT AT BOTTOM OF BATTENS R-10 UNFACED RIGID FOAM RATED FOR CRAWL d ° SPACE APPLICATION o CONTINUOUS GLUE OR CAULK BETWEEN STEM WALL & MUD SILL, MUD SILL & RIM, BETWEEN RIM d ° & SUBFLOOR, AT TOP OF CRAWL SPACE VAPOR d BARRIER TO INTERIOR STEM. EXISTING STEM WALL & ' CRAWL SPACE. ADD 4 BLOCK TO SECURE VAPOR BARRIER CLASS 1 VAPOR BARRIER ° ° °d CLASS 1 VAPOR BARRIER & INSULATION. SEE ° 4'_ WHERE POSSIBLE, INSULATION & VAPOR BARRIER TO PLANS FOR VENTILATION. 4 BE APPLIED TO WITHIN 4" OF TOP INSIDE OF STEM d WALL. APPLY EXTERIOR RIGID FOAM TO TOP 4" OF d STEM WALL. CRAWLSPACE VAPOR BARRIER TO BE SEALED TO EXPOSED FOOTINGS & POSTS w/ MESH TAPE & MASTIC. WALL SECTION: EXTERIOR INSULATION, NO FIRE RATING, J FLAT CEILING EXISTING CRAWLSPACE 1" = 1'-0" INSULTYPICAL @ HEADERS EXISTING EXTERIOR WALL, CEILING & ROOF STRUCTURE TO REMAIN. ADD INTERIOR INSULATION. EXISTING WALL SHEATHING & SIDING REMOVE INTERIOR GWB & BATT INSULATION EXTEND WALL STUDS ON INTERIOR SIDE 1.75" w/ FOAM -BACKED FURRING STRIPS. FILL GAPS w/ SPRAY FOAM WHERE NECESSARY. R-21 BATT INSULATION @ EXPANDED STUD BAYS. RIGID FOAM INSULATION @ HEADERS & WALL PLATES WERE POSSIBLE. LAPPED," CEMENT FIBER SIDING FASTENED TO BATTENS VAPOR RETARDER SEALED AT TOP, BOTTOM & SEAMS ROOFING TO BE ASPHALT SHINGLES OR METAL ROOFING WITH APPROVED UNDERLAYMENT FLASHING TO BE INSTALLED IN A MANNER THAT PREVENTS MOISTURE FROM ENTERING Eave of addition within 5' of existing garage roof to be 1 hour fire -rated RAISED HEEL PLATED ROOFING ROOF SHEATHI INSUL TYPICAL @ HEADERS NOTE: NO INSULATION @ GABLE ENDS OF ATTIC. FURR OUT TO MATCH FACE OF SIDING. SEE ENGINEERING DRAWINGS FOR FRAMING SIZES AND DETAILS AND NAILING. R-49 BATT INSULATION DO NOT COMPRESS 5/8" GYP WALL BOARD EXTEND WALL STUDS ON INTERIOR SIDE 1.75" w/ FOAM -BACKED FURRING STRIPS. FILL GAPS w/ SPRAY FOAM WHERE NECESSARY. WALL SHEATHING WALL FRMG 2x6 STUDS @ 16" O.C. MIN. R-24 FACED BATT INSUL 1- HR CEMENT FIBER SIDING OR PANELS T.B.D. EXTEND WALL STUDS ON INTERIOR SIDE 1.75" w/ FOAM -BACKED FURRING STRIPS. FILL GAPS w/ SPRAY FOAM WHERE NECESSARY. VAPOR RETARDER SEALED AT TOP, BOTTOM & SEAMS PROTECTIVE COATING APPROVED BY RIGID INSULATION MANUFACTURER FLASHING PRESSURE TREATED MUDSILL z SILL SEAL & CAPILLARY BREAK SEE ENGINEERING PLANS FOR FOOTING d ° � DIMENSIONS & CONIC REINFORCEMENT R-10 UNFACED RIGID FOAM RATED FOR CRAWL d d ° ° d ° ° d SPACE APPLICATION d ° , d ° CONTINUOUS GLUE OR CAULK BETWEEN STEM EXISTING STEM WALL & WALL & MUD SILL, MUD SILL & RIM, BETWEEN RIM ° d ° ° °d ° d ° ° ° R 10 FACED RIGID FOAM w/SEAM ° CRAWL SPACE. ADD 4 ' °d & SUBFLOOR, AT TOP OF CRAWL SPACE VAPOR a ° ° TAPE & INSECT BARRIERS ABOVE CLASS 1 VAPOR BARRIER BARRIER TO INTERIOR STEM. & INSULATION. SEE d ` — N ° d GRADE. DO NOT SEAL SEAMS ° ° °° BELOW GRADE. REPAIR TEARS IN ° PLANS FOR VENTILATION. ° a ° ° ° ° FACING. ° ° d BLOCK TO SECURE VAPOR BARRIER ° °° d CLASS 1 VAPOR BARRIER 4" PERF. DRAIN TIE TO EXIST ° CONTINUOUS GLUE OR CAULK BETWEEN STEM ° TIGHT LINE ° ° WALL & MUD SILL, MUD SILL & RIM, BETWEEN RIM CRAWLSPACE VAPOR BARRIER TO BE SEALED TO SYSTEM ° ° & SUBFLOOR, AT TOP OF CRAWL SPACE VAPOR EXPOSED FOOTINGS & POSTS w/ MESH TAPE & ° ° d BARRIER TO INTERIOR STEM. MASTIC. OVERLAP 12" @ JOINTS & SEAL w/ TAPE. SEAL ALL TEARS & HOLES MADE DURING CONSTR. SEAL ALL CRACKS & JOINTS RADON/MOISTURE BARRIER WALL SECTION: INTERIOR INSULATION, NO FIRE RATING, WALL SECTION: INTERIOR INSULATION, 1 HOUR FIRE E F I- if ) FLAT CEILING EXISTING CRAWLSPACE 1" = 1'-0" RATING FLAT CEILING SLAB ON GRADE 1" = _ / J 1 1 James Hardie Technical Bulletin #19 https://www.jameshardie.com/JamesHardieMainSite/ media/SiteDocuments/Tech Design advice Any information or assistance provided by James Hardie in relation to specific projects must be approved by the relevant specialists engaged for the project eg. builder, architect or engineer. James Hardie will not be responsible in connection with any such information or assistance." Example diagram from James Hardie US Technical Bulletin #19 Figure from USTB 19 demonstrating how to fasten cement fiber to wood furring and how to fasten wood furring over exterior insulation directly into framing. Specific members of the assembly in this image shall not supersede those in Details A-F on pages A-5 and A-6, but this fastening approach shall be used. While James Hardie makes clear in USTB 19 that "the siding attachment system design is the responsibility of the design professional," Method 2 Guidance in James Hardie USTB 19 as well as USTB 19 Tables A.1, A.2, and A.3 (recreated below) shall be CI CI CIII.Cu uullll�' IdJLClllllb'. Method 2: Applying Hardie® Siding to Furring Installed Over Non-Nailable Substrates up to 4 inches thick: When applying James Hardie Siding to furring strips, which Is applied on foam sheathing or other non-naiiable substrates (e.g. gypsum sheathing) with a combined thickness up to 4 Inches thick, the foam sheathing and other non-nailable substrates do not have nail holding capacity. For that reason, the designer needs to reestablish the siding's nail holding surface. When applying by this method, the nail holding substrate for the cladding is the furring strips. The basic premise of Melhod 2 is to reestablish the nail base overtop the foam sheathing by installing a furring that has sufficient thickness to accommodate the James Hardie® Siding fastener. EXTERIOR WALL COVERING ASSEMBLY {y� Siding fastener (nail or screw) (face or blind nail, see relevant installation instructions) James Hardie Fiber -cement Siding Wood furring, WSP, or steel furring Furring fastener Thickness of rigid foam sheathing, as required ❑pt€onaI wall sheathing, as required by applicable building code (e.g. gypsum sheathing, WSP, or other) Wall framing per code (e.g. wood or steel studs) Consult water -resistive harrier fWRBj manufacturerfor plorement of WRB. Figure 2: Exterior VMl Assembly for Siding applied to Furdnq NOTE: If layerF ftm Figure 2 above is a non-nadable substrate fe-g. gypsum sheathing), the combined thickness of layers E + F must he less than 4 inches. Table A.1: James Hardie Product Literature TAIRLIE A.y. JAMES HAIMbIE PRODUCT UTE RATLEpE PMDUCT SUBJECT UATITR LINK HatdiaPlari Lap 5idlM, Iliivdl stab SidN. HardiaSINIni Eking Ir•,r:. I!r:r'.^ !'r': Ert :' r•h"•.1= .: • . 'E",9M3r1M H_.. I ::.::.:, . Iss hl_.:.;,r:r..,:_ Coj-Apprgh,-•. hffp �fimmii.'Irqw5hs.'rflF.—3r'1.'I%-IwVi�rMF.sirgRlrldrFgrer_1wrhnCdIDWAnnKr15 !�ltml EonlplafA Sidf*. EErnper mI9 SidFlg 1p.sull Code ApRmahi 1r chrrmIpDprlmetrla_cMtrpl nr it " (op Rim Pfevall1- Patio Siding MsWII Irt'incl1u-II:3 htM r :-:xling.cofnl Apprmls .r! . . diN.s�rl�11d�1k1�9t?dA5i�18uldC�lil�d_1eCtIIti�IRI]!�uR1�11s 5[Ih111 tr,'.. .. :,dn4aUr'f van:ir All9 iprr fNrrrl Adis A k.Rp Sking In.01 IrWrok C X Appl' elG htlp;ir W :'��"�I dIC. OB1 by f�d LMld' fkGl�_1dC lr C �11]C�lftl�lTla" IkIN Ffir "Sl5niIgcbr.2L1: .iwrms KardieTed II Lal5erricm- 1- KO- 9+42-7?43 Table A:; James Hardie Siding Weight TABLE A. 2: JAIVIES HARDIE STING WEIGHT PR00I1GT THICKNESS pNCFIESI POUNDS PER SQUARE FOOT' HiRd4F'L�n1!4�r S�� 5f 1$ P:5 HamleperlquD SKMg bmr rtka �rs:rp S11� Is DmTprOe Sdng 511fi 2.3 Pre,al IW I•ap 50 A 2.5 Vrevel11,0 Panel Edeq vis s.$ ArlisanG Lap &ciao S1 4.G HardiuMin l& 9uart N4 44 Harrlld'MrDG ,IruEBRO Foment Torn 1- in E Table A.3. Softwood Furring Weight TABLE A-1 SGF rWOOU FURRING WEIGHT, I11 MI = AL TUAIL SIB PURRINt WEIGH1 COKTRI BLITN)N AT SPAGJNG (Ile X Illt} firs x i+l] fmnl M rnirl� W&IghI 18 W. 0G 24 Ih: OC (Ih�l11�i IP!1 (PSO I �. 2 19 Jii U.1i T r 3 19116L 0.47 1 Kd r:x 191i�g 0•E4 G.' 1 K6 31`4x512 1�K140 1 0::•.. 1 xB 'N4x7114 19x1P4 1.3 0.90 0-05 x �1f x11 383B 0.55 0.41 2 K 3 11f2X2 30N114 D.D4 0.71 0.47 2K4 .38xsg .28 0.95 4C-4 2 % 5 ':2 359140 2 1.50 1 CI} b8 1?4 1 38x19 198 1; The Er@net:nlrg ?212. rrtfpllrtxw.�+]I�en-� titaa�a r�.'��5opd•Iu�Gl'Omen�rr�•d_7#6�lstrnl Table AA: Design G u idance on Furring Attachme nt for Ja riles H and ie Sid ing TAIBLE#4: WS" GUIDAPI ON FUAMNGAT-FA910Ef#1`f%JAMES HAIIS.101HG RMI1 W R51.11 G THICKNESS Rt r ANIf EMPi1l EMAIL TEC# LREPORiS` Nil 1INC) I MEMBER FFSfUill TIF'E PIfDW H IM 7E11 W 1DN:0 'Gee al mam,m p'�' Fmdem FWAI'a� , rimer I � 17"& tie mA�ril agree EI[I Fate I!5'9 ilk hYI�IPI.L�17 Mrim_rn 25! YeW *WIFrinl!MThomhrCI;iM Nabs J wi lyis : Nuod '5LWt%AW4yq1AM YW m1159ga1�I1' FSIYr! Fhlrli rNthhltww9n?xYle�rl111 vq' 4h ptrjpJD CYyrrieH 6x99c1b pip Y"N8MIXotArnk' killrrrran 7 d graV 5€JFrIi kilrrrum 20 � rinlrum 3 mll mhd r.A Vdtt.4 4ThLlt{p O Will ,.r 4mw �� r� 3Wrr+q rritu ew"fm arl��' k4i11F�k]h.FSFIrI`�lsat�p :A rei4 Cmlrar r.r. `��yp �nelhd kfnir 110 • �19 *111 #tell � I i lalrxl sbe',Y,dhculr %note H4r KiUti�ir{%rrndlgrA+�Tr� oarrl 9r�aWrn Y! ftelia", GaJSW 0 T W-VII Drawings and the Associated cad files are considered instruments of service' and may not be used for any other project or for any addition to this project or for completion of drawings by others. iAll rights reserved. REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT s o 4—' � --Izs S � � z H O V [ �x �z �U x rq u' r, V) rn 1: — o Mi U _J w00 N Lo LID ZQ _ N s -1 lc� U LLr K�_ W Q fn s p 1:W s — _J U � J J DATE PLOTTED 8/7/2023 iSCALE i varies FILE NAME Hill plan c SHEET A-6 GENERAI STRIIC:TIIRAI NOTES (The following apply unless shown otherwise on the plans) THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE ALL CONNECTIONS/FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED OR FIRE -RETARDANT -TREATED WOOD, SHALL BE OF INTERNATIONAL BUILDING CODE. SUBSTITUTIONS SHALL HAVE CURRENT ICC-ES APPROVAL. HOT DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL. HOT DIPPED GALVANIZED FASTENERS SHOULD CONFORM CRITERIA TO ASTM STANDARD 153, AND HOT DIPPED GALVANIZED CONNECTORS SHOULD CONFORM TO ASTM STANDARD A653 (CLASS G- A. CONCRETE ANCHORS 185). STAINLESS STEEL FASTENERS AND CONNECTORS SHOULD BE TYPE 304 OR 316. NOTE: ELECTROPLATED GALVANIZED 1. ALL MATERIALS WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE 1. MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR FASTENERS AND CONNECTORS ARE NOT TO BE USED WITH PRESSURE TREATED WOOD. SIMPSON PRODUCT FINISHES 2018 INTERNATIONAL BUILDING CODE (IBC) INCLUDING WASHINGTON STATE MODIFICATIONS. USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193. PRE -APPROVED MECHANICAL ANCHORS INCLUDE: CORRESPONDING TO THE ABOVE REQUIREMENTS ARE ZMAX (HOT DIPPED GALVANIZED) AND SST300 (STAINLESS STEEL). a. SIMPSON STRONG -TIE "STRONG -BOLT 2" (ICC-ES ESR-3037) STAINLESS STEEL HARDWARE AND FASTENERS SHALL NOT BE COMBINED WITH UNTREATED OR GALVANIZED MATERIAL. 2. DESIGN I DARING CRITERIA b. SIMPSON STRONG -TIE "TITEN-HD" (ICC-ES ESR-2713) SNOW LOAD ROOF SNOW LOAD, Pf = 25 PSF c. HILTI "KWIK BOLT TZ" (ICC-ES ESR-1917) IMPORTANCE FACTOR, Is = 1.0 27. WOOD FASTENERS: EXPOSURE FACTOR, Ce = 1.0 2. ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR THERMAL FACTOR, Ct = 1.0 USE IN ACCORDANCE WITH ICC-ES AC308. PRE -APPROVED ADHESIVE ANCHORS INCLUDE: A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SLOPED ROOF FACTOR, CS = 1.0 a. SIMPSON STRONG -TIE "SET-XP" (ICC-ES ESR-2508) b. SIMPSON STRONG -TIE "SET-3G" (ICC-ES ESR-4057) SIZE LENGTH DIAMETER FLOOR LIVE LOAD (RESIDENTIAL) 40 PSF c. SIMPSON STRONG -TIE "AT-XP" (IAPMO UES ER-263) 6d 2" 0.113" d. HILTI "HIT -RE 50043" (ICC-ES ESR-3814) 8d 2-1/2" 0.131" WIND (MAIN WIND FORCE RESISTING SYSTEM) BASIC WIND SPEED = 97 MPH e. HILTI "HIT-HY 200" (ICC-ES ESR-3187) 10d 3" 0.148" ALLOWABLE STRESS DESIGN WIND SPEED = 75 MPH 12d 3-1/4" 0.148" IMPORTANCE FACTOR, Iw = 1.0 won 16d 3-1/2" 0.162" RISK CATEGORY = II TOPOGRAPHIC FACTOR, Kzt = 1.0 18. FRAMING LUMBER SHALL BE KILN DRIED OR MC-19, AND GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD DESIGN IS BASED ON COMMON STEEL WIRE NAILS MEETING THE REQUIREMENTS OF ASTM F1667. USE OF ALTERNATE EXPOSURE CATEGORY = B GRADING RULES FOR WEST COAST LUMBER NO. 17, LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS. FASTENERS MUST BE SUBMITTED FOR REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER PRIOR TO THE START OF INTERNAL PRESSURE COEFFICIENT, (GCpi)= 0.18/-0.18 CONSTRUCTION. WIND BASE SHEAR (N/S) = 4.49 KIPS JOISTS: HEM -FIR NO. 2 WIND BASE SHEAR (E/W) = 2.80 KIPS (2X, 3X, AND 4X MEMBERS) MINIMUM BASE VALUE, Fb = 850 PSI B. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. EARTHQUAKE (EQUIVALENT LATERAL FORCE PROCEDURE) Ss = 1.285 RFAM ANn STRINGERS: DOUGLAS FIR LARCH NO. 1 Sds = 1.028 (6 X AND LARGER MEMBERS) MINIMUM BASIC DESIGN STRESS, Fb = 1,350 PSI S1 = 0.452 28. WOOD FRAMING NOTES - THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: Sd1 = 0.557 POSTS ANn TIMBERS: DOUGLAS FIR LARCH NO. 1 IMPORTANCE FACTOR, le= 1.0 (6 X AND LARGER MEMBERS) MINIMUM BASIC DESIGN STRESS, Fb = 1,200 PSI, FC = 1,000 PSI A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE SITE CLASS D INTERNATIONAL BUILDING CODE. MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.10.1 OF SEISMIC DESIGN CATEGORY= D STUDS PLATES & MISCELLANEOUS LIGHT FRAMING DOUGLAS FIR LARCH OR HEM -FIR NO. 2, THE INTERNATIONAL BUILDING CODE. UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE AS SPECIFIED ABOVE. RISK CATEGORY = II MINIMUM BASIC DESIGN STRESS Fb = 850 PSI, FC = 1,300 PSI COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE R = 6.5 FOR WOOD STRUCTURAL PANEL SHEAR WALLS WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. INSTALLATION OF BOLTS OVER STRENGTH FACTOR, Do = 3.0 19. LAMINATED STRAND LUMBER (LSL): EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT NUMBER OF AND LAG SCREWS SHALL CONFORM TO SECTIONS 12.1.3 AND 12.1.4 OF THE 2018 NATIONAL DESIGN SPECIFICATION FOR DEFLECTION AMPLIFICATION FACTOR, Cd = 4.0 THE MANUFACTURER, THE GRADE, PRODUCT DESIGNATION OR TYPE, THE PRODUCTION DATE, SPECIES OR SPECIES GROUP WOOD CONSTRUCTION. NATURALLY DURABLE OR PRESSURE TREATED WOOD SHALL BE PROVIDED WHERE REQUIRED BY REDUNDANCY FACTOR = 1.0 DESIGNATION, AND THE QUALITY CONTROL AGENCY. MEMBERS SHALL BE GLUED WITH A WATERPROOF ADHESIVE MEETING THE SECTION 2304.12 OF THE INTERNATIONAL BUILDING CODE. SEISMIC RESPONSE COEFFICIENT, Cs = 0.158 REQUIREMENTS OF ASTM D2559 WITH ALL GRAIN PARALLEL WITH THE LENGTH OF THE MEMBER. STRUCTURAL CAPACITIES SHALL SEISMIC BASE SHEAR = 9.5 KIPS BE ESTABLISHED IN ACCORDANCE WITH ASTM D5456 AND PRODUCT SHALL HAVE AN APPROVED ICC-ES EVALUATION REPORT. B. WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2X6 AT 16" O.C. TWO STUDS MINIMUM MEMBERS SHALL BE TRANSPORTED AND STORED PER MANUFACTURERS RECOMMENDATIONS AND SHALL NOT BE EXPOSED TO SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS. TWO 2 x 8 HEADERS SHALL BE RAIN INTENSITY 1.0 INCHES/HOUR PROLONGED MOISTURE. MINIMUM REQUIRED DESIGN PROPERTIES: Fb = 2325 PSI, Fv = 310 PSI, E = 1,550,000 PSI, PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED AND SHALL BEAR FULLY ON A MINIMUM OF TWO STUDS. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE SOLID 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. LSL RIM JOISTS SHALL CONFORM TO ANSI/APA PRR 410 AND SHALL BE MARKED IN ACCORDANCE WITH THE STANDARD. BLOCKING BETWEEN STUDS AT MID -HEIGHT OF ALL STUD WALLS OVER 10, IN HEIGHT. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE INTENDED FOR DESIGN SHOWN ON PLANS IS BASED ON LUMBER MANUFACTURED BY WEYERHAEUSER. ALTERNATE MANUFACTURERS MAY BE STUDS MAY BE NOTCHED, CUT, OR PENETRATED WITH ROUND BORED HOLES AS FOLLOWS: REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER, ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER STUD SIZE MAXIMUM NOTCH / CUT MAXIMUM BORED HOLE 4. CONTRACTOR SHAI L PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH MEMBERS PROVIDED. 2X4 7/8" 1-3/8" CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 2X6 1-3/8" 2-1/8" 20. PREFABRICATED OPEN WER WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER FOR THE SPANS AND CONDITIONS 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES, OR SHOWN ON THE PLANS AND SHALL BE FURNISHED AND INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED BORED HOLES SHALL NOT BE LOCATED WITH 5/8" FROM THE EDGE OF THE STUD OR AT THE SAME LOCATION AS A NOTCH PROCEDURES REQUIRED TO PERFORM THE WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY SPECIFICATIONS. ALL NECESSARY BRIDGING, BLOCKING, PRE -NOTCHED PLATES, ETC. SHALL BE DETAILED AND FURNISHED BY OR CUT. OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS THE MANUFACTURER. SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS MEETING THE REQUIREMENTS OF IBC SECTION RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, 2303.4 (COMPLETE WITH STRESS DIAGRAMS) TO THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL FOR REVIEW WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH TWO SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CONTRACTORS, OR OTHER PRIOR TO FABRICATION. DESIGN SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF A REGISTERED PROFESSIONAL 16d NAILS, AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16d NAILS. FACE NAIL DOUBLE TOP PLATE ENTITIES OR PERSONS AT THE PROJECT SITE. ENGINEER, STATE OF WASHINGTON. PERMANENT AND TEMPORARY BRIDGING SHALL BE INSTALLED IN CONFORMANCE WITH WITH 16d AT 12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE EIGHT 16d NAILS AT 4" O.C. EACH SIDE OF JOINT. MANUFACTURER'S SPECIFICATIONS. 6. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 12" APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS 21. PREFABRICATED PLYWOOD WEB JOIST DESIGN SHOWN ON PLANS IS BASED ON JOIST MANUFACTURED BY THE WEYERHAEUSER. O.C. STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS (WITH 7" MINIMUM EMBEDMENT) @ 4'-0" REQUIREMENT. ALTERNATE PLYWOOD WEB JOIST MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND O.C. UNLESS INDICATED OTHERWISE. PROVIDE 3"x3" x1/4" HOT -DIPPED GALVANIZED PLATE WASHERS AT ALL ANCHOR STRUCTURAL ENGINEER. ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN BOLTS. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH 16d NAILS @ 12" O.C. 7. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER STAGGERED. REFER TO THE PLANS AND SHEAR WALL SCHEDULE FOR REQUIRED SHEATHING AND NAILING. WHEN NOT INDICATED, BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, HARDWARE SHALL BE COMPATIBLE IN SIZE WITH PLYWOOD WEB JOIST PROVIDED. OTHERWISE NOTED, PROVIDE GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO ALL STUDS, TOP AND BOTTOM SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. PLATES AND BLOCKING WITH NAILS AT 7" O.C. USE 5d COOLER NAILS FOR 1/2" GWB AND 6d COOLER NAILS FOR 5/8" GWB. 22. PREFABRICATED CONNECTOR PI ATE WOOD ROOF TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE PROVIDE 15/32" APA RATED SHEATHING (SPAN RATING 24/0) ON EXTERIOR SURFACES NAILED AT ALL PANEL EDGES 8. ALL STRI ICTIJRAI SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY WITH THE "NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION", ANSI / TP 1-2014 FOR (BLOCK UNSUPPORTED EDGES), TOP AND BOTTOM PLATES WITH 8d NAILS @ 6" O.C. AND TO ALL INTERMEDIATE STUDS THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE, AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS THE SPANS AND CONDITIONS SHOWN ON THE PLANS. LOADING SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: AND BLOCKING WITH NAILS @ 12" O.C. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS. PREPARED BY THE SUPPLIER. TOP CHORD LIVE LOAD REFER TO DESIGN LOADING CRITERIA C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE 9. STATEMENT SPEC:IAI INSPECTIONS- MINIMUM TOP CHORD DEAD LOAD 10 PSF THAN HALF THE JOIST LENGTH AND AROUND ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE THE FOLLOWING CONSTRUCTION TYPES ARE TO BE REVIEWED BY A SPECIAL INSPECTOR DESIGNATED BY THE OWNER OR MINIMUM BOTTOM CHORD DEAD LOAD 5 PSF SOLID BLOCKING AT ALL BEARING POINTS. ARCHITECT. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION WIND UPLIFT (TOP CHORD) VARIES, TO BE CALCULATED BY TRUSS MANUFACTURER NOTCHES AT THE END OF JOISTS AND RAFTERS SHALL NOT EXCEED 1/4 THE DEPTH OF THE MEMBER. NOTCHES IN THE REQUIRING SPECIAL INSPECTION. SPECIAL INSPECTION SHALL CONFORM TO SECTION 1704 OF THE 2018 INTERNATIONAL REFER TO DESIGN LOADING CRITERIA TOP OR BOTTOM SHALL NOT EXCEED 1/6 THE DEPTH OF THE MEMBER AND SHALL NOT BE LOCATED WITHIN THE MIDDLE BUILDING CODE. SPECIAL INSPECTION AGENCY SHALL BE RESPONSIBLE FOR KEEPING RECORDS OF SPECIAL INSPECTIONS AND 1/3 OF THE SPAN. THE DIAMETER OF ROUND HOLES BORED IN JOISTS AND RAFTERS SHALL NOT EXCEED 1/3 OF THE TESTS. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE FURNISHED WITH COPIES OF ALL WOOD TRUSSES SHALL UTILIZE APPROVED CONNECTOR PLATES (GANG -NAIL OR EQUAL) AND SHALL BE CONFIGURED SUCH THAT DEPTH OF THE MEMBER AND SHALL NOT BE LOCATED WITHIN 2" FROM THE TOP OR BOTTOM EDGE. INSPECTION REPORTS AND TEST RESULTS. THE MAXIMUM OPENING BETWEEN MEMBERS DOES NOT EXCEED 42"X24". SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS MEETING THE REQUIREMENTS OF INTERNATIONAL BUILDING CODE SECTION 2303.4 TO THE ARCHITECT, STRUCTURAL ENGINEER, TOENAIL JOISTS TO SUPPORTS WITH TWO 16d NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH POST INSTALLED ANCHORS: PERIODIC SPECIAL INSPECTION IN ACCORDANCE WITH THE PRODUCTS APPROVED ICC-ES REPORT. AND BUILDING OFFICIAL FOR REVIEW PRIOR TO FABRICATION. SUBMITTED DOCUMENTS SHALL BEAR THE STAMP AND SIMPSON METAL JOIST HANGERS IN ACCORDANCE WITH NOTES ABOVE. NAIL ALL MULTI -JOIST BEAMS TOGETHER WITH SIGNATURE OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHINGTON. PROVIDE FOR SHAPES, BEARING POINTS, TWO ROWS OF 16d @ 12" O.C. ATTACH RAFTERS AND ROOF TRUSSES AT BEARING LINES WITH H2.5 @ 24" O.C. UNLESS (;EnTEC'HNI('AI INTERSECTIONS, HIPS, VALLEYS, ETC. SHOWN ON THE DRAWINGS. EXACT COMPOSITION OF SPECIAL HIP, VALLEY, AND INTERSECTION AREAS (USE OF GIRDER TRUSSES, JACK TRUSSES, STEP-DOWN TRUSSES, ETC.) SHALL BE DETERMINED BY THE OTHER METAL CONNECTIONS ARE INDICATED. 10. FOUNDATION NOTES: ALLOWABLE BEARING PRESSURE AND COEFFICIENT OF FRICTION HAVE BEEN ASSUMED PER IBC TABLE MANUFACTURER UNLESS SPECIFICALLY INDICATED ON THE PLANS. PROVIDE ALL TRUSS -TO -TRUSS AND TRUSS -TO -GIRDER UNLESS OTHERWISE NOTED ON THE PLANS, APA RATED ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH STRENGTH 1806.2. LATERAL EARTH PRESSURES HAVE BEEN ASSUMED PER IBC TABLE 1610.1. IT HAS BEEN ASSUMED THAT EXISTING SOILS TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. PROVIDE FOR ALL TEMPORARY AND PERMANENT TRUSS AXIS PERPENDICULAR TO SUPPORTS AND ATTACHED WITH 10d NAILS @ 6" O.C. TO FRAMED PANEL EDGES AND OVER ARE A COMBINATION OF SAND, SILTY SAND, AND POORLY GRADED SAND-SILT/SAND GRAVEL MIXES. IF SOILS ARE FOUND TO BE BRACING AND BRIDGING. THE TRUSS MANUFACTURER SHALL COORDINATE LOCATIONS AND SUPPORT CONFIGURATIONS OF STUD WALLS AS SHOWN ON PLANS AND @ 12" O.C. TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. PLUMBING, MECHANICAL UNITS, DUCT WORK, AND OTHER MISCELLANEOUS ITEMS WITH THE CONTRACTOR PRIOR TO CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES FABRICATION. TRUSSES SHALL BE DESIGNED TO SUPPORT ALL LOADS ASSOCIATED WITH SUCH ITEMS. THE TRUSS SHOP SHALL HAVE APPROVED TONGUE -AND -GROOVE JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED GRADE, UNLESS OTHERWISE DRAWINGS SHALL INCLUDE ALL DESIGN LOADS AND APPROVED HANGER CONNECTION DETAILS TO TRUSS CHORDS FOR SPACING AT ALL PANEL EDGES AND ENDS OF ALL ROOF AND FLOOR SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH NOTED, FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE. SUPPORT OF HUNG MECHANICAL SYSTEM COMPONENTS. ANY VARIATION FROM THE BEARING POINTS INDICATED ON THE 16d NAILS @ 12" O.C. UNLESS OTHERWISE NOTED. AT BLOCKED FLOOR AND ROOF DIAPHRAGMS PROVIDE FLAT 2X STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR APPROVAL. BLOCKING AT ALL UNFRAMED PANEL EDGES AND FASTEN SHEATHING TO FRAMING/BLOCKING AS SPECIFIED. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. 23. OPEN wEB \8100D RI ISRES ARE TO BE TJL SERIES AS MANUFACTURED BY WEYERHAEUSER. TRUSSES SHALL BE DESIGNED BY ALLOWABLE SOIL PRESSURE 2,000 PSF THE MANUFACTURER FOR THE SPANS AND CONDITIONS SHOWN ON THE PLANS AND SHALL BE FURNISHED AND INSTALLED IN LATERAL EARTH PRESSURE (RESTRAINED/UNRESTRAINED) 60 PCF/45 PCF CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. ALL NECESSARY BRIDGING, BLOCKING, PRE - LATERAL EARTH PRESSURE (SEISMIC) 8H (ULTIMATE LOAD) NOTCHED PLATES, ETC. SHALL BE DETAILED AND FURNISHED BY THE MANUFACTURER. SUBMIT SHOP DRAWINGS AND DESIGN PASSIVE EARTH PRESSURE (INCLUDES FACTOR OF SAFETY = 1.5) 150 PCF CALCULATIONS MEETING THE REQUIREMENTS OF INTERNATIONAL BUILDING CODE SECTION 2303.4 (COMPLETE WITH STRESS COEFFICIENT OF FRICTION (INCLUDES FACTOR OF SAFETY = 1.5) 0.25 DIAGRAMS) TO THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL FOR REVIEW PRIOR TO FABRICATION. DESIGN SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHINGTON. CONCRETE PERMANENT AND TEMPORARY BRIDGING SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS. DESIGN LOADS SHALL MEET OR EXCEED THE FOLLOWING: 11. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH ACI 318-14 AND ACI 301-16. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH (fc) OF 3500 PSI BASED ON EXPOSURE CLASS F1, SHALL CONTAIN NO LESS THAN 5-1/2 SACKS OF MINIMUM TOP CHORD LIVE LOAD REFER TO DESIGN LOADING CRITERIA CEMENT, HAVE A MAXIMUM WATER/CEMENT RATIO OF 0.45, MAXIMUM AGGREGATE OF 3/4-INCH, AND A SLUMP OF 5 INCHES OR LESS. MINIMUM TOP CHORD DEAD LOAD 10 PSF DEAD LOAD CONCRETE HAS BEEN DESIGNED BASED ON A CONCRETE STRENGTH (f'c) OF 2500 PSI PER INTERNATIONAL BUILDING CODE SECTION MINIMUM BOTTOM CHORD DEAD LOAD 5 PSF DEAD LOAD 1705.3 EXCEPTION 2.3 TO AVOID SPECIAL INSPECTIONS AND MATERIAL TESTING. WIND UPLIFT (TOP CHORD) VARIES, TO BE CALCULATED BY TRUSS MANUFACTURER ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT REFER TO DESIGN LOADING CRITERIA CONFORMING TO ASTM C260, C494M, AND C618. UNLESS OTHERWISE NOTED THE TOTAL AIR CONTENT SHALL BE 5%. AIR CONTENT SHALL BE SAMPLED IN ACCORDANCE WITH ASTM C172 AND AIR CONTENT MEASURED IN ACCORDANCE WITH ASTM C231 TRUSS SUPPLIERS NOTE: THE TRUSS CONFIGURATIONS, INCLUDING DEPTHS AND MEMBER SIZES SHOWN ON THE DRAWINGS, OR C173. INDICATE THE DESIRED TRUSS CONFIGURATION AND ARE TO BE COMPLIED WITH WHEREVER POSSIBLE. IF THE TRUSS MANUFACTURER IS UNABLE TO MEET THE LOAD REQUIREMENTS SPECIFIED WITH THE TRUSS CONFIGURATION INDICATED THE 12. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENTS S1), GRADE 60, Fy = 60,000 PSI. EXCEPTIONS: ANY MANUFACTURER IS TO SUBMIT WRITTEN NOTICE TO THAT AFFECT TO THE ARCHITECT PRIOR TO SUBMITTING A COST PROPOSAL BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, Fy = 40,000 PSI. OR BID. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 IF A DIFFERENT SYSTEM IS PROPOSED THAT REQUIRES REVISIONS TO PRESENT STRUCTURAL FRAMING OR DETAILS, SUCH SYSTEM SHALL BE CONSIDERED SUBJECT TO THE APPROVAL OF THE OWNER, ARCHITECT, AND STRUCTURAL ENGINEER. 13. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN ACCORDANCE WITH ACI SP-66-04 AND ACI 318- IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND TRUSS MANUFACTURER TO VERIFY THE WEIGHT AND LOCATIONS 14 CHAPTER 25. LAP ALL REINFORCEMENTS AS FOLLOWS: OF ALL MECHANICAL EQUIPMENT PRIOR TO SUBMITTING SHOP DRAWINGS. IT SHALL BE NOTED IN THE TRUSS MANUFACTURER'S BID WHETHER OR NOT AN ALLOWANCE HAS BEEN MADE FOR MECHANICAL UNITS. BAR SIZE MINIMUM LAP LENGTH MINIMUM HOOK EMBEDMENT 24-INCHES -IN HE 24. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH DOC 4 1-IN HE 8-INCHES PS 1-09 OR PS 2-18 AND AMERICAN PLYWOOD ASSOCIATION PERFORMANCE STANDARD PRP-108. ORIENTED STRAND BOARD OF 5 -IN HE 11-IN HES EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. SEE PLANS FOR THICKNESS, PANEL IDENTIFICATION INDEX AND NAILING REQUIREMENTS. EACH PANEL SHALL BE IDENTIFIED FOR GRADE AND GLUE TYPE BY PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM THE TRADEMARKS OF AN APPROVED TESTING AND GRADING AGENCY. OF 8" AT SIDES AND ENDS. 25. ALL WOOD PI ATFS IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN APPROVED NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR PRESERVATIVE, PROVIDE 2 LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER BETWEEN UNTREATED LEDGERS, BLOCKING, APPROVED BY THE STRUCTURAL ENGINEER. FIELD BENDING OF GRADE 60 REINFORCEMENT SHALL NOT BE ALLOWED. ETC. AND CONCRETE OR MASONRY. 14. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: PRESSURE TREATED LUMBER SHALL COMPLY WITH THE AMERICAN WOOD PROTECTION ASSOCIATION (AWPA) STANDARD U1, COMMODITY SPECIFICATION A AS INDICATED BELOW OR HAVE EQUIVALENT ICC-ES APPROVAL. FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" ALL OTHER CASES 1-1/2" ALL TREATED LUMBER SHALL BEAR THE QUALITY MARK OF AN ACCREDITED INSPECTION AGENCY. THE QUALITY MARK SHALL INCLUDE: 15. SLABS -ON -GRADE: UNLESS NOTED OTHERWISE SHALL BE 4" CONCRETE, REINFORCED WITH 6X6 W1.4XW1.4 WELDED WIRE FABRIC CENTERED IN SLAB. UNLESS OTHERWISE DIRECTED BY SOILS REPORT PROVIDE MINIMUM 10 MIL VAPOR BARRIER OVER 4" OF A. IDENTIFICATION OF TREATING MANUFACTURER COMPACTED SAND OR GRAVEL. B. TYPE OF PRESERVATIVE USED C. MINIMUM PRESERVATIVE RETENTION (PCF) 16. CAST -IN -PI AGE CONCRETE SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF DOOR AND WINDOW D. END USE FOR WHICH THE PRODUCT IS TREATED OPENINGS IN ALL CONCRETE WALLS. SEE MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF MISCELLANEOUS MECHANICAL E. IDENTITY OF THE ACCREDITED INSPECTION AGENCY OPENINGS THROUGH CONCRETE WALLS. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE F. STANDARD TO WHICH THE PRODUCT IS TREATED STRIPS, COLOR, TEXTURE, AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. TOLERANCES FOR ALL STRUCTURAL CONCRETE AND REINFORCEMENT SHALL BE IN ACCORDANCE WITH ACI 117-10 AND ACI 117.1 R-14. 26. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER C-C-2019. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY POST INSTAI I ED ANCHORS HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER TO ACHIEVE THE MAXIMUM PUBLISHED ALLOWABLE LOAD. ALL CONNECTORS SHALL BE INSTALLED IN 17. POST-IN_STAI LED ANCHOR SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING POST -INSTALLED ANCHORS IN PLACE OF PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. SHIMS, WHERE REQUIRED, SHALL BE SEASONED AND DRIED AND MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST -INSTALLED ANCHORS TO AVOID THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. CONFLICTS WITH EXISTING REINFORCEMENT. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND ICC-ES REPORT. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL SPECIFIED BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER -OF -RECORD ALONG WITH CALCULATIONS THAT BOLTS AND LAG SCREWS BEARING ON WOOD. ALL LAG SCREWS SHALL BE INSTALLED IN PRE -DRILLED HOLES. ARE PREPARED & SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF WASHINGTON. THE CALCULATIONS SHALL DEMONSTRATE THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF UNLESS NOTED OTHERWISE ALL SAWN LUMBER JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST HANGERS AND ALL PREFABRICATED PLYWOOD WEB JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "IUS" SERIES JOIST HANGERS. Drawings and the associated cad files are considered 'instruments of service' and may not be used for any other project or for any addition to this project or for completion of drawings by others. All rights reserved. REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Z Q O W � Q 0 Z O J T- CY) 0 1 (O W Z Z D 0 ry W u7 C)°' W00 z 0 � w Z Z Lu N 00 p. z\\0w N U a a O No C3 U m _ x w _J z N rn "> F-- ~ w DATE PLOTTED 1 /3/2023 SCALE none FILE NAME HILL STRUCTURAL SHEE SI ALLEY 15' rear setback 2 x 6 C@ 24" J.C. SSKI0 L F7 r-n -F 76.13' SW - 1 SW1 existing gar.dr. header i — ---——— I I I I I I I I I r-I 1 In I I — I I ' - I — I I I 1 I I Wood Framing Plan Notes EXISTING ROOF FRAMING 1. Roof sheathing shall be 15/32" AP A Rated sheathing with a — — — — panel index of 24/0. Nail to framing with 8d common nails at- 6" oc at panel edges and 12" oc in field unless noted otherwise on plans. Roof has been designed for 5psf Photovoltaic Panels. 1 45 2. Typical floor sheathing shall be 23/32" APA, Sturd-I-Floor with a panel index of 40/20. Nail to framing with 1 Od common nails at 6" oc at panel edges and 12" oc in field unless noted 1 — — — — — — — — — — — — — — — —v otherwise on plans. 1 1 3. All headers and beams shall be (2) 2x8 minimum, u.n.o. Refer to note 4 for support requirements. 4. All columns shall be double stud minimum, u.n.o., with the — beam or header bearing fully on the column. Individual studs — shall be nail together per the general structural notes. 5. All slabs -on -grade shall be 4" reinforced with WWF6x6 W l .4xW 1.4 u.n.o. Provide minimum 10-mil polypropylene 1 vapor barrier under all slabs. Slabs shall rest on a minimum 4 inches of free draining material. 0— — — — — — — x Eave of addition r1 SW-x Indicates shearwall per schedule within 5' of existing 1_ — N — — — — — — — — — — — — — garagerooftobel � � �c x x l x/ x x x x x/ x xis s•' �� � �� x x x' n xrx lx `x x' x x x x `x x x x x x x i ��x hour fire -rated— _ _ _ _ _ MSTxx Indicates Simpson Holdown „ „ „ , v HDUxx x x ' J L Indicates Simpson Hanger r K \ SW -1 / ( i \ x U = nk hd ' - `I tubul r �kylit --� t---� 1t--1 II I I I I I I° existing h r L�� �� L- 0 x FLAT CEILING 00 ^/x �K N N Y/ 00 V N \ x ^ N V K 'V'~ N Y �ix� j-- x SW-1 CS- 16 L x N � i VAULT CEILING N `x N 3-1/2 X 11-7 8 LS Attic ventilation \x vaulted clg = 437 sf \ x flat clg = 771 sf `x total vented roof area = 1208 sf 0 x \ = 8.05 sf 00 ; , SSK-A = 8.05x144 = 1159.2 s.i. required x 00 rV N 3.5x22 f.p. eave vent @ 41 s.i. each `N x N = 615 s.i. supplied @ eave x x I I� continuous 20"per ft ridge vent = `x tubular 1188 s.i. supplied @ ridge Total ventilation supplied = 2846 s.i. \" skylite pp 00 o \x N Ln In \ x' m I PRE -MANUFACTURED ROOF TRUS % I INcc x Eave of \x\ addition Ln 00 x within 5' of J'U x x property SSK-A Q t] N J N ' ; line to be 1 � > `x hour `x fire -rated `x 00 x, VAULT CEILING Nr xi FLAT CEILING �' / x I I � I I N x%i 00 I IN VAULT C ILING Lx ` 2248 attic x , N access z ` I CIO I = � X x „ (n N , IL N z 0c PRE -MAN UFACTURED ROOF TRUS x` Ioo 1 x x � N x exist) g hdr e fisting r x 13-1/2 11-7 LSL N \ tubular, K. �kylite'j ISSK-C I I I I I I I I I I I I F AT CE11 ING < ' v, --C---]----C---]----C---]----C---]-- -CJ \ / �C) FLAT CEILING {'\ Q) / 2 x 12 @ 24" O.C. \ / l LL l FIAT CEILII G I \ / N N Ln I I II �1/I II II II II I��I � >;�] ci >' > y \I it / Imo_ Imo— - (2) 2x SW-3 ; / �I� I� I� I rt I I I I I I \ existing hdr o PROPOSED - ROOF FRAMING PLAN 1/4" = 1'-0" U M Ln ALLEY 15' rear setback 76.13' Ln ILLJJ LI_ 11 c-I HDU2 HDU2 ■.1?= r----------------------------------------- EXISTING GARAGE I SLAB I NO CHANGE 1 I 1 I I I I I 1 1 1 I I I I I 1 I 1 I I I I I 1 I I I I I I 1 1 I SSK-G L--------------------------------------J r 26'-8" NEW 4" SLAB ON GRADE 6-2" 2'-11" SSK-F 13' `^ washer/dryer min.24" square Zn 4x10 min.2 " square 1 rt - 4-x - oo— ------------- Z.0 7— *10 J 4x1 L I—J _ O0 L-- N Ll 4 x 10`�' I 9-1 2" TJI 1 0 I _ _ _ @ 16" O.C. I LUS48 HAN ERCD 1 X6 - X 1 NEW > — — 3' 7° I ^ CR WLSPACE 4 1 3 5'-9 121 7' 1 1 [1.00583xl44=15 TAL CRAWL PACE AREA = 1587.45 sf SSK A I I CLASS VAPOR BARRIER iv 1 1587.4 / 1500 = 1.0583 �� 2.39 s.i. ventilation req'd I OUTLINE OF of I I A EXISTING STEM o� of (2) RECTANGUL R 73 s.i. VENTS = 146 s.i. (2)ROUND .9s.i.VENTS=9.8s.i. I �., �------ i � x �I I TOTAL I = 155.8 s.i. r----------------------- 1 9-1/2" TJI 110 @ 16" O.C. 1 1 9-1/2" TJI 110 @ 16" O.C. ' I LJ_ m n.24" square I I HDU2 I I 7— I I 1 a 6x OP L L SSK-H �I I LJ I of I I I REVISE AND IMPROVE 00 01 I 1 L I EXISTING '� X i ❑ I CRAWLSPACE I I I iIn. 24:'square j13' —1 — 1 '-11" EXISTING DECK NO CHANGE a 6x L — I —I — HDU2 I SSK-E of i I I #4 x 2'-0" EPDXY 4' 1" 5' 9" 1'-1 XI I 14'- DOWEL SPACE TO ❑ ❑ MATCH HORIZ.El I I i i REINF. TO I I r, EXISTING FOUNDATION. I I EXISTING S AIR TO 4" MIN. EMBED I LI BASEIV ENTN CHANGE f-6" min j I I 2" x 34" min. 1 F:,II 1 ------------------------------ - -I- - ---— — — — — — — — — — — — — — — — — — — I I I I I I I I I I I I 6X6 W/ MIN 24 SQUARE FTG I I I I I I I r--------II-7 1 2' EXISTI BASEMENT N CHANGE SS -P I I I I I I I I 9-1/2" TJ 1 110 °@ 16" O.C. 3-1/2 x 9-1/2 LSL FB I I I I I I I I I I I I I I I I 6X6 W/ MIN 24 SQUARE FTG I L-------- — — — — — — -------J L----------- ------J --------- F 2.5" round vent to be REMOVE UNDERMINED STEM 2r1b"1 ■ I located min 6" below top L I I 6x6 ��y{ 1 1 24 x 24 x 10 of stem wall = 4.9 s.i. 1 1 1 i Pleases a calculation packei C ulz tion i I �i i 1 vi i I states that the 6x 10 is a DF1 I ■ II M I I existing 2x6 framing "' � N 9-1 2" TJI 110 101 � � 9-1/2" TJI 110 1 1O �I I @ 16" O.C. I�� @ 16" O.C. 1 U IN. 1 i i 24x24x10 11" 1 r ■�■�■�■�■�■�■ �■ ■--7 2'-7" 2'-5' I I 1 1 _0 LJ (a) L---L 6x6 L---L 1 N Q) I I I Ln 1 • — I I I I 1 I EXISTING 1 Ln CRAWLSPACE RETROFIT w/ NEW SSK-0 VENTS & CLASS 1 _ 1 VAPOR BARRIER 1 En I I 00 HDU4 L — — -- ------ — ---J I I a e o 73 s.i. vent I I -------------------- l— #4 x 2'-0" EPDXY DOWEL SPACE TO MATCH HORIZ. = REINF. TO EXISTING FOUNDATION. 4" MIN. EMBED 6" min I I I I L----------------------------------------------- I 12'-5" I ------------------------ ---0 2.5" round vent to be EXISTING STOOP located min 6" below top EXISTING NEW EXISTING PAVEMENT NO CHANGE of stem wall = 4.9 s.i. NO CHANGE V 0 PROPOSED - FOUNDATION PLAN 1/4" = 1'-0" Drawings and the associated cad files are considered 'instruments of service' and may not be used for any other project or for any addition to this project or for completion of drawings by others. All rights reserved. REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT o � o w o Q � O Q 2 J M 0 2 cMo W Z Z 0 I..L W Urn Z-1 W 00 Lu Z N ao Z U LLJ Q Q O \/ � o N C3 U ~ X LLJ J M Z = o W I..I.J IL N (n DATE PLOTTED 8/7/2023 SCALE VARIES FILE NAME HILL FINAL DEMO ADD SHEE— S2 BYKONEN QUINN BYKONEN CARTER QUINN Foli deQ}h blir LI�11 f +� be dri IiPd ar n'c�c�a� S hey nal I — fer p1,n STRUCTURAL ENGINEERING a fsove CIT o-- So schedule fop F-xaS7- Fa0 i SN6 ■ 2033 Sixth Avenue #(9!95 Seattle, WA 98121 206-264.7784 www.BCO-SE.com PROJECT Idpr)C _..._ ..- ._.._. ......... LATE... ...... c p DESIGNER _... ..... ....._-. ..._...._ _........ SHEETS .___ `' .,...T.. F1CW frGsf'Oy Poy-Ply,r k la' ty- UP6 R nctiar 6❑ It i:�Lqa rv'rx ►+ 4z. FY- ■ 2433 Sixth Avenue "95 Seattle. WA 98121 206-264-7784 www.BCO-SE.com PRgfECT..._._WO RQSIdew STRUCTURAL .. .... ...... DATE ..... _..... .... ENGINEERING DESIGNER:_-__......................... .__.._._ ..... . SHEET #:._._S� k - q I ) q " AL'WAI TvuErt�aF�nn � -lo BYKONEN ■ 2033 Sixth Avenue #995 Seattle, WA 98121 206-264-7784 www.BCQ-SE-Com CARTER QUINN PROJECT: ...... 1. ._�i,UC1iC Q . _ .__ .._ ........ STRUCTURAL .._......... DATE ENGINEERING DESIGNER: SS K-o _._._..._............._._....__....._.._._.._......... SHEET f:....................................... .... i BYKONEN 30, 2033 Sixth Avenue #995 Seattle. WA 98121 206-264-7784 vvww.BCQ-SE.com CARTER QUINN PROJECT _....._ _. DATE ._......_ _.__,_....._._. STRUCTURAL ENGINEERING DESIGNED De ......... _..... _..._.... ........ .... ...... _ SHEET,_ BYKONEN CARTER QUINN fpv r1r4rn frc,, i r_y ply n ram, 05 Peer 064 n CCAARTERN QUINN ■ 2433 Sixth Avenue #995 Seattle, WA 98121 205-264-7784 wvdw.BCQ-SE.Com BYKONEN PROJECT C[1IL _ fd1P-Ac� INN_R --_._... DATE STRUCTURAL $ E ENGINEERING DESIGNER ......... . _.-............. _._ SHEET f Fu I it depth rfi I' 7 1 rnPG ` vy 11[ rein L; fl Ft;+r""t�jal i �Pr f'IGn STRUCTURAL ' ENGINEERING jab en �Y�P Per Plug STRUCTURAL ENGINEERING R� 1 ■ 2033 Sixth Avenue #995 Seattle, WA 98121 206-254.7784 www.BCQ-SE.com PROJECT �t 1 I ►'e"i F�eang DATE: rr DESIGNER SS F -4 ---—•..... ..............._ SHEET A:..._..............._......------ ■ 2033 Sixth Avenue 0995 Seattle, WA 98121 296-264-7784 www.BCQ-SE.cotn PROJECT .... f� l� 1L�51f�'r7GQ_ ............ _...... . DATE CC yy��� DESIGNER:...... . ..._..... ......... ......... SHEET / .5.] Lam .- 4+ 1'6" MI.A). �'o" AlTN. Fr) �uARE P1J/JTR R1 --4F W1 (4)V9 x C tR 12 rS 1? el "at C�\-) Pfr M- D.AS $a r BYKONEN ■ 2033 Sixth Avenue #995 Seattle, WA 98121 206-264-7784 www.BCQ-SE-Cam CARTER QUINNF L � PROJECT :.... ...t �_1.�. $tL[Pil/F STRUCTURAL .... .... ......... ....... _..... DATE: __....... _.... .... .... ENGINEERING DESIGNER - G - ........ ................ ............ ..................... _..... SHEET f:...S s k Anchcw ha0- Dr, �r0fdr rev pllio _ #w @ T'ot vca >i 4f C NCI— litAil- �1L�5 dry 5 ]0b A 00 1 I f f i i I BYKONEN ► 2433 Sixth Avenue #995 Seattle, WA 98121 206-264-7764 www.BCQ-SE.com CARTER QUINN l}i4 fes;�[erxe -A, PRDJEGT:..... ..... .._.._.__.. .,........, DATE: .... STRUCTURAL ENGINEERING Des cNER: SHEET ... _..... ....... ��........ ...... A � J + Cr TW (r t Fill-+ TA IS L I-tvL3 Z + —/ 203J Sixth Avenue #995 Seattle, WA 98121 206-264-7784 www.SCQ E.com -- - -- STRUCTURAL PROJECT ..— .. DATE ENGINEERING DESIGNER; ..... . ..... ........ ....... SHEET# i'-tlac " i �•.e17 C to Nailing -towhl'oti: J A Bo I� 5 to capacity(PIf, �palrty I p f. f. • • .. Sheathing I�r7�dR'I� Panel Iw3i li i7� ` _ top plate L�� Rini J>.: is ! � y below ._ [ Mt ram heICEW. I PI�I M �Fl -�W 1 15/32' APA Sheat hi na 'des Eld 6' 0C CLIP @ 24 '.oc 2x� 13A" LS L 16d @ b"i>c 5/8" LB 48'ax 240 3.3G SW 2 15132" APA Sheat hi na Ves ad 4„ cc : CLIP @ 2 T-oc 2x� i3A' LS5_ 16d @ 4�c-"c : 5/9' La 48".0r 355 497 -�W 3 15 f32" APA Sheati-li ng 'Yes 8d 3" cc � CLIP @ 16 ac 2XJ ice" LS _ I 16d @ 3%'Gz S�-G" La 3 6"cic 455 fa 7 i Mails shall ti�e Bd ba.x_ Flailing applies to a II panel -ecf-g-es (bi ack a II uns,uppa#ed pare; edges) tGp & bolittam plates and Wac ring- Fail to interm ediate framing memilbers~ wl Sd q• 12"oc. (hlube : whre re stud spacing is 24'i3Cr nai I tD i nterm-ed iat-e framing members with 8d@6' oc) Framing at adjoining panel -edg-es shall b•e 3--inch ream ina I or Crider and nails shaf l he StaGg end . a Clip shal I ae- either A3 5 , LTP-4 5 Nailln Tall he iG.d Inny (0.13SOOM') or 10d cummon (0.14;9Ox3l�'') Srr-ews shal I he Simps an SD3255011 (1/4'OxYmiin) 6 pravide 3' x "x.O.2 213' plate crasher at all anchor bolts. Anchor bcilts shall t1�e parsitianed such that plate edge cif plat-e washer is kwith 112' of th-e edge of the twttom plate. ( Plate 4wasi-mrs may ti-e dia€3anal Iy slatted with a width of up to 13116' a n-d a length rkat to -exceed I W" ) Drawings and the associated cad files are considered 'instruments of service' and may not be used for any other project or for any addition to this project or for completion of drawings by others. All rights reserved. REVISION Aug 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT o � o w o Q � O Q � J M 0 2 cMo W z z_ D 0 w U z 0 00 1: W Z Z W N 00 a. LJJ z�w U 'a a Op \/ N c3 U ~ X W J >- z = o w IL N N DATE PLOTTED 6/22/2023 SCALE none FILE NAME HILL STRUCTURAL SHEE T S3