SEE REV3 APPROVED BLD PLN ENG RESUB3 BLD2023-0027+SITE & Architectural_Plan+5.16.2023_7.41.25_AM+3546408SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM
COVERAGE
GARAGE
588
EXISTING HOME
1036
DEMO
261
ADDITION
949
WINDOW SEAT
14
-----------------------------------------------
DEMO 261
ADDITION 949
WINDOW SEAT 14
TOTAL NEW CONDITIONED 1224
DRIVEWAYS 367
ROOFS W/ OVERHANGS 3170
HARD SURFACING 659
TOTAL IMPERVIOUS SURFACES 4196
EXISTING IMPERVIOUS SURFACES
HOUSE ROOF 1485
GARAGE ROOF 711
HARD SURFACES 514
DRIVEWAYS 858
TOTAL EXISTING IMPERVIOUS SURFACES 3568
ADDED IMPERVIOUS SURFACES = 4196-3568 = 628 SF
TOTAL NEW & REPLACED IMPERV SURF = 1353 SF
TOTAL IMPERVIOUS
TOTAL LOT
Type of area
Square footage
Stormwater facility
Driveway
no new or replaced area
New dry well to be used for
replaced 261 sf and new
949 sf of roof area.
Existing splashblocks to be
used for existing roof areas.
Roofs w/ Overhangs
1353 sf
Hard Surfaces
no new or replaced area
X% Retrofit
n.a.
2" x 2" WOOD/STEEL
FILTER FABRIC SECURED
TO 2" x 2IC " 14 GA
WIRE FABREQUAL
0
(V
NATIVE BACKFILL MATERIAL J 8"
FILTER FABRIC MATERIAL IN CONTINOUS ROLLS
USE STAPLES OR WIRE RINGS TO ATTACH
FABRIC TO WIRE
2" x 2" WOOD/STEEL POSTS
WIRE MESH FENCE
o `TO SUPPORT FILTER
FABRIC
N
BURY BOTTOM OF FILTER
MATERIAL 8" TO 12"
6' MAX
N
TOTAL ROOF
AREA w/
OVERHANGS
3170 SF
NOTES:
1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER
EROSION CONTROL THROUGHOUT PROJECT. CITY INSPECTION REQUIRED ON
2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ALL EROSION CONTROL METHODS
ACTIVITY. BEFORE OTHER WORK CAN BEGIN
REVISION DATE
FILTER FABRIC FENCE JANUARY 2018
CITY OF EDMONDS FILTRATION SYSTEMS
PUBLIC WORKS STANDARD
DEPARTMENT DETAIL
APPROVED BY: R. ENGLISH E R - 9 00
DRIVEWAY
150 sf
EXISTING
GARAGE
588 SF
ADDITION
ALL NEW
CONSTRUCTION
949 SF
Demolished
Area
ALL NEW
Hard Surface CONSTRUCTION
338 sf 261 SF
Alterations Worksheet - 2018 Washington State Energy Code
Project Information Contact Information
Hill addition & remodel Linda Mackin
633 Alder LKMackin@gmail.com
Edmonds, WA
The WSEC requirements for alterations are located in Chapter 5 of the code text.
Alterations (remodels) do not need to obtain energy credits from Table R406.3
Additions must meet the requirements for new construction. This includes nonconditioned space being
altered to become conditioned space.
Will the wall cavities be exposed? Yes n No
If yes: Exposed wall cavities must be insulated -
2 X 4 wall studs require R-15 insulation
2 X 6 wall studs require R-21 insulation
Will the roof/ceiling framing cavities or attic be exposed? 11"] Yes C No
If yes: Exposed roof/ceiling assemblies must be insulated -
Vaulted ceilings: Insulate to the full depth of the framing member
while allowing for the minimum 1" ventilated space
Flat ceilings: Install R-49 insulation or what the attic space can
accommodate based on the roof pitch
Will the floor framing cavities be exposed? ❑Yes n No
If yes: Exposed floor cavities must be insulated to R-30
Are the windows and/or doors being replaced? Ev] Yes C No
(includes both window or door and frames)
If yes: New windows and doors must have an area weighted average U-factor of <_0.30
Will the heating or cooling system be replaced?FOYes F No
If yes: New equipment must meet current requirements and
ducts need to be tested
Will the hot water system be altered? n Yes F No
If yes: New water heating equipment must meet current code requirements
Are more than 50% of the light fixtures being changed? Yes No
If yes: 90% of all lamps must be high efficacy
(LED or CFL)
EXISTING
HOME
1036 SF
Hard Surface
69 sf
AREA PLAN 1" = 10'-0"
ENERGY NOTES:
TOTAL NEW
& REPLACED
IMPERV. SURF.
= 1 '1S'l CF
Hard
>urfac(
252 sf
DRIVEWAY
217 sf
GRATE
FILTER SOCK WITH
OVER FLOW HOLES
(TYP)
CATCH BASIN
\ NOTES:
`CATCH BASIN
1. CONTRACTOR/DEVELOPER SHALL MAINTAIN
THIS APPLICATION AT ALL TIMES DURING
CONSTRUCTION PERIOD.
2. ANY SEDIMENT IN CATCH BASIN INSERT
SHALL BE REMOVED WHEN INSERT IS
ONE-THIRD FULL.
3. CITY INSPECTION REQUIRED ON ALL
EROSION CONTROL METHODS BEFORE
OTHER WORK CAN BEGIN.
REVISION DATE
TEMPORARY JANUARY 2018
SEDIMENT TRAP
FOR CATCH BASINS STANDARD
DETAIL
APPROVED BY: R. ENGLISH E R- 9 0 2
Addition to comply with 2018 Washington Energy
code
Energy code compliance is per SEC R402.1.1 -
Prescriptive
An Insulation Certificate for Residential
Construction shall be posted withing 3' of the
electrical panel prior to final inspection
Air leakage shall not exceed 5 air changes/hour and
shall be tested and certified prior to final inspection
A minimum of 75% of lamps in lighting fixtures shall
be high efficacy lamps
New windows in remodeled areas to have max U
factor of 0.30.
Where framing is exposed in remodeled areas R
values to be min.
R-15 @ 2x4 stud walls
R-30 @ floors
R-10 continuous & 2' depth @ slab on grade
R-49 @ ceiling or depth of roof joists
1224 sf addition
Small dwelling unit = 3 credits:
Heating option 2: heat pump = 1.0
Option 5.5: heat pump water heater = 2.0
-------------------- ----
..........
QELECTRICAL - OVERHEAD O
O`'. G GAS ALLEY 76.13'
15' rear setback
---
I I I
I I
I I I
I I I
I I I
I I I
I I
__ w
I I
one RS-6 Corner Flag Y I�
I I I
-----------------------------
etbacks: Required Actual R
,l ----------
-----------
gara8edoo
20' 14' eoo maa
ront
Jest 5 15 L-- - -----I-- - -- --�
ast 5' 5' I''', ° Rem ----
5' shed 811011
.ear •------ °
25' 18'9" m \
eight m°ke
1 % ede
APPROVED BY PLANNING _ Q Remveportioao,drive
NEMOVEENTIRE
" oRTHIA
ooinoN
,
1� ��-
May 23 2023
-
Nothing in the permit approval process shall be l_________________
- 1
interpreted as allowing or permitting the maintenance _ _ _ _
-epae T
of any currently existing illegal, nonconforming or -------------- =_ _=_ _T°
unpermitted building, structure or site condition which wam°.e =
is outside the scope of the permit application, regardless j a'emo e
O p°rti°°or ------j,' y
of whether such building, structure or condition is G a _ - i; i
Rer "ew ------
shown on the site plan or drawing. Such building,
structure or condition may be the subject of a separate U \ i
\ / -
enforcement action. vv i enladge Rem°
0
CB RIM = 103.48
103.48 IE 121. PVC (N)=98.76
PP RIM_- IE 12" PVC (S) = 98.68
D
IE 12" PVC(N)=98. 6
IE 12 PVC(S)-98.6
SD 5D
ss
v G gas \ opening. w
N I
\I/
R- - - - - - - - - - - - rva ve low--�----------------Re -
win
i ai
', emove dow _dIvi&nd wall.
wi d w
x
�-
L-
Replace \ \ Repdows. '1 O I windows.
L--------- --- ----- 1----------
J �obep,eseryed
I o
I
20' fronts tback _
S SEWER 76. 3' ALDER STREET
WATE R
water
meter
ALDER STREET
SO SD (�P SD SD SO o�P SD
ss
ss
____________-_-________-__________-_-________-__________ __ SS SSMH RIM = 106.65
IE 8" PVC (E) = 96.38
IE 8" PVC (W) = 96.28
SSMH RIM- 106. 65
IE 8" PVC(E)=96,38
IE 899 PVC-96.28
2018 Washington State Energy Code - Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Single Family- New & Additions (effective February 1, 2021) -
Each dwelling unit in a residentialbuilding shall cam l withsufficient options from Table R406.2 (fuel
normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of
credits. To claim this credit, the building permit drawings shall specify the option selected and the
maximum tested building a it leakage, and show the qualifying ventilation system and its control sequence
of operation.
1. Small Dwelling Unit: 3 credits
Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area.
Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf.
2. Medium Dwelling Unit: 6 credits
All dwelling units that are not included in #1 or #3
3. Large Dwelling Unit: 7 credits
Dwelling units exceeding 5,000 sf of conditioned floor area
4. Additions less than 500 square feet: 1.5 credits
All other additions shall meet 1-3 above
Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4.
Summary of Table R406.2 and 406.3
Pleating Credits - select ONE
❑ bons Fuel Normalisation Descriptions heating option User Notes
p
1 Combustion heating minimum NAECA4 0.0 ❑
2
Heat pump`
1.0
0
3
Electric resistance heat only - furnace or zonal
-1.0
❑
4
DHP with zonal electric resistance per option 3.4
0.5
5
All other heating systems
-1.0 ❑
Credits - select ONE
Energy
❑ lions
p
Energy Credit Option descriptions
energy option from each
category
Water heating system shall include one of the following: Electric heat pump water heater
meeting the standards for Tier III of NEEA's advanced water heating specification or
5 5 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier Ill of 2.0
NEEA's advanced water heating specification, shall supply domestic hot water to all units. If
one water heater is serving more than one dwelling unit, all hot water supply and
recirculation piping shall be insulated with R-8 minimum pipe insulation. s
Energy
Options
Summary of Table
Energy Credit Option Descriptions (cunt.)
Efficient Water Heating
Efficient Water Heating
Efficient Water Heating
R406.2 (cant.)
Credits - select ONE
energy option from User Notes
each categoryd
0.5 ❑
5.1a
5.2
0.5
❑
5.3
1.0
❑
5.4
Efficient Water Heating
1.5
❑
5.5
Efficient Water Heating
Efficient Water Heating
2.0
2.5
0
5.6
❑
6,1e
Renewable Electric Energy (3 credits max)
1.0
0
❑
7.1
Appliance Package
0.5
Total Credits
3.0
alculate Total
Clear Form
U
M
a--+
N
a)
to
J.
o�
I
I
o'I
O' I
i
EXISTING - SITE PLAN 1" = 10'-0"
NO STORMWATER MANAGEMENT SYSTEM
REQUIRED AT THIS TIME. IF NEW AND/OR
REPLACED IMPERVIOUS SURFACE EQUALS
UELECTRICAL
-
OVERHEAD
�,
O
2000SQFT OR GREATER, A STORMWATER
0`,,
S
76.13'
MANAGMEMENT SYSTEM MAY BE REQUIRED
PER CITY CODES AND STANDARDS
I
-
-
�
GRADE
� � � W
FILTER FENCE SEE
�
0
,-I
ELEV
15'
rbar setbd`ck
ER900
104.5'
1
00
w VEGETATED
R�
y, GLADE
y. y. y. �,
FLOWPATH
ELEV
w w
102.A'
w w . . v
INSPECTION REQUIRED
PRIOR TO BACK FILL
W
W
w TEMPORARY STOCKPILE
:I
i
W w
COVER WITHIN 24 HOURS �✓
-
i-
SITE DATA
c
ADDRESS: 633 Alder, Edmonds, WA
b
I
PARCEL # 00434209502800
ZONING: RS-6
cV
LOT SIZE: 8239 SF (per survey)
� �
� �
� � � ��as" diam. x 3
deep drywell w/
PROJECT SCOPE:
drainage rock I.
drainfilter ages
REMOVE PREVIOUS 261 SF ADDITION
°`c
:kin:ng
REMODEL 122 SF INTERIOR
ALL DISTURBED AREAS TO BE
OF 949 SF INCLUDING 1 ADDITIONAL BEDROOM &
'',
COMADDITION
2014 SWMMWW ED PER
20145WMMWW BMPT.5.13
�.
2 l-1011
BATHROOM, RELOCATION OF LAUNDRY & MASTER SUITE,
------------rT
ADDITION OF MUDROOM. ADDITION OF WINDOW SEAT.
INSTALLANDCATCH
BASIN SEE
---
--------- - - - - -
REPLACEMENT OF EXISTING WINDOWS THROUGHOUT.
MEASURISALLTESC
ER-902
�-
JI
ACCORDING TO
EXISTING MAIN LEVEL: 1297
APPROVED PLANS,
EXISTING GARAGE: 588 SF
CITY OF EDMONDS
O
EXISTING LOT COVERAGE: 1885 SF
STANDARD DETAILS,
OTHER
PROTECT TREES
;
MEASURES THAT MAY
w/ LIMIT OF
PROPOSED MAIN LEVEL: 2260 sf
BE REQUIRED DURING
CONSTRUCTION
PROPOSED GARAGE: 588 SF
CONSTRUCTION.
FENCING
---------
:I
PROPOSED LOT COVERAGE: 2848 SF = 34.6 %
TREES IN
;
ALLOWED LOT COVERAGE 35% = 8239 x 0.35 = 2883.65 SF
BACKYARD
TO BE
TOTAL PROPOSED IMPERVIOUS SURFACE: 4196 SF
_ _
�
RETAINED
; N
EXISTING IMPERVIOUS SURFACE: 3568 SIF
NEW IMPERVIOUS SURFACE = 628 SF
Ln
.I
PROPOSED PARKING SPACES: 3
REQUIRED PARKING SPACES: 2
HEIGHT CALCS:
r-
A=+102.8'
Ql
B=+104.5'
0
C=+105'
D=+107.8'
I
; Foo
I
ing
TOTAL=+420.1'
drai
i pert
AVERAGE GRADE = 420.1/4=105.025
pipe
ou
around
e.
SEWER
SEW
:R
Tie-
nto
PROPOSED MAXIMUM HEIGHT: 123.935'
CLEANOUT
CLEAN
UT
exis
ing
ALLOWED MAXIMUM HEIGHT: 130.025'
-�
-� -
soli
footin€
Idrai to
talc basin
\
splas'M1g
bla k
'
-
\
v v
u
04,
V A WHOLE
HOUSE
\\
\\
I
�' EXHAUST
\\ FAN 65
ro Q,
N
U
\
CFM w/
\ ' \
a)
INTERMITTENT
\\ \\
;
72
N
�' OFF/ON
\ \ CONTROLS
;
G
\
Ln
\IY
N
-----------------------
- - - - - - -
12="Y
A
NOTE:
pl ng
nla°d
_wl
/ A A i
lD
MIN
HORIZONTAL
SEPARATION & 1'
VERTICAL
GRADE
ELEV ---------
---- ----- y-------------- is�i"g
GRADE
SEPARATION IS
105'
/ J bract
N ELEV
REQUIRED
107.8'
BETWEEN DRY
0
UTILITIES AND
-
UJ
SEWER, WATER
PROTECTTREES
=
AND STORM AND
w ��
W/ LIMIT OF
5' FROM ANY CITY
MAIN LINES
CONSTRUCTION W\
>I'
L'
FENCING - v
a �
�
ro
I \
Q
0'f onts t ack
D
S SEWER
76. 3' ALDER STREET
EXISTING SIDE
SEWER LOCATION /
WATE R
CONNECTION TO
r ^
v 1
T,
REMAIN
water
� meter
D
CB RIM = 103.48
PP RIM=103.48 E12"PVC (S) 98.8 O I
IE 12" PVC (s) = 98.68 0 li
D
IE 12" PVC(N)=98. 6 C::�
'I
ALDER STREET
I
II
i
SD SD SD SD SD SD SD SD O SD li
I
l
III
ss -
- - --- ---- --- - -- - - - - - - - -- S S ss ---------- - - --------------
ss - - - - -- - ---- --- - --- - ----------------------
ss
--------------------------------- - -
_---_ -____ __ _ _------ SSMH RIM - 106.65
----- -- -- - -- IE E PVC (E) = 96.38
I E 8" PVC (W) = 96.28
DATUM POINT: SSMH RIM=106.65
SEWER MANHOLE IE g" PVC(E)-96.38
RIM = + 106.65' IE 8" PVC(W)=96,28
10-1
PROPOSED -SITE PLAN 1" = 10'-0"
Drawings and the
associated cad files
are considered
'instruments of
service' and may not
be used for any
other project or for
any addition to this
project or for
completion of
drawings by others.
All rights reserved.
ALL
lAfORK
SUBJECT'
FIELD
NSF
CTION FOR
C
D
OMPLIANCE
r■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
; The following documentation shall be available on ! ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY OWNER/CONTRACTOR RESPONSIBLE FOR
site for the building inspector:
■ UTILITIES MAY REQUIRE A SEPERATE PERMIT. EROSION CONTROLL AND DRAINAGE
;
■
SITE DATA
;QCOE APPROVED ARCHITECTURAL PLAN
SET
!GENERAL NOTES
ADDRESS: 633 Alder, Edmonds, WA
COE APPROVED STRUCTURAL PLAN SE
GOVERNING BUILDING CODES:
PARCEL # 00434209502800
COE REVIEWED CALCULATION PACKET
! ALL CONSTRUCTION SHALL COMPLY WITH LOCALLY ADOPTED BUILDING CODES AND AMENDMENTS.
ZONING: RS-6
; ENERGY CREDIT WORKSHEET
! CONTACT CITY FOR GOVERNING UNIFORM BUILDING CODE, UNIFORM PLUMBING CODE, UNIFORM
! SITE PLAN
MECHANICAL CODE, UNIFORM ELECTRICAL CODE AND UNIFORM FIRE CODE.
CIVIL PLAN
;ALL PRODUCTS SHALL BE INSTALLED PER 2018 IRC AND ICC AND MANUFACTURERS'
LOT SIZE: 8239 SF (per survey)
'
CALCULATION PAGE DATED 4/25/2023
mVRITTEN INSTRUCTIONS. PRODUCT SUBSTITUTIONS FOR PRODUCTS LISTED SHALL
■ X
SHOWING SEPARATION DISTANCES
:ALSO HAVE 2015 IRC AND ICC APPROVED EVALUATION REPORTS OR BE APPROVED AND LISTED BY OTHER
❑
NATIONALLY RECOGNIZED TESTING AGENCIES
PROJECT SCOPE:
'
REMOVE PREVIOUS 261 SF ADDITION
■
CITY OF EDMONDS BUILDING DEPARTMENT 2021
'■■■■■■■■■■■■■■■■■■■■■�■■■■■■■■■■■■■■■■■■■■■■■■■BALL
ALL LUMBER MUST BEAR AN APPROVED GRADING STAMP AND BE NOT LESS THAN GRADE SHOWN ON DWGS
■
PLYWOOD USED IN EXTERIOR LOCATIONS SHALL BE EXTERIOR GRADE
REMODEL 122 SF INTERIOR
ALL STEEL MUST BE ASTM AS SPECIFIED ON DRAWINGS
ADDITION OF 949 SF INCLUDING 1 ADDITIONAL BEDROOM &
EXTERIOR PAINT TO BE SHERWIN WILLIAMS SUPERPAINT OR EQUAL APPLIED ACCORDING TO
MANUFACTURERS INSTRUCTIONS
BATHROOM, RELOCATION OF LAUNDRY
& MASTER SUITE,
FOUNDATIONS SUPPORTING WOOD SHALL EXTEND AT LEAST 8" ABOVE ADJACENT FINISH GRADE
ADDITION OF MUDROOM. ADDITION
OF WINDOW SEAT.
CONSTRUCTION SHALL CONFORM TO INT. FIRE CODE. APPROVED CARBON MONOXIDE ALARM REQ'D
REPLACEMENT OF EXISTING WINDOWS THROUGHOUT.
OUTSIDE OF EACH SLEEPING AREA
City Of Edmonds
PROVID
SPARK ARRESTORS @ ALL FIREPLACES AS REQ'D BY CITY ORDINANCE
EXISTING MAIN LEVEL. 1297
PROVIDE
FIRE SPRINKLER SYSTEM AS REQ'D BY LOCAL ORDINANCE
EXISTING GARAGE: 588 SF
Building Departmeot
MISC. SITE
STRUCTURES, SWIMMING POOLS, SPAS, FENCES, SITE WALLS (INCLUDING RETAINING WALLS)
^N.'r) ('A
STORAGE TANKS REQUIRE SEPARATE PERMITS
EXISTING LOT COVERAGE: 1885 SF
Work LARGE EDITION
ALL EXI-TS
TO BE OPENABLE FROM THE INSIDE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE
PROPOSED MAIN LEVEL: 2260 sf
I I
Address 633 ALDER ST
PROPOSED GARAGE: 588 SF
Owner HILL
SHEET INDEX:
PROPOSED LOT COVERAGE: 2848 SF =
-----------------------------------------------------
: . o
Approved Date 6/05/202
ALLOWED LOT COVERAGE 35% = 823
xgn,& .65 SF
AL-1: SITE PLANS, GENERAL NOTES, ENERGY NOTES
TOTAL PROPOSED IMPERVIOUS SURF
I
r i ngk�er BLD2023-0027
4-2: DEMOLITION PLAN, PROPOSED PLAN
EXISTING IMPERVIOUS SURFACE: 356
NEW IMPERVIOUS SURFACE = 628 SF
REVISIONS
A-3: EXISTING EXTERIOR ELEVATIONS
PROPOSED PARKING SPACES: 3
DATE - PAGES - CHANGES
REQUIRED PARKING SPACES: 2
REV1
REV2
A-4: PROPOSED EXTERIOR ELEVATIONS
HEIGHT CALCS:
REV3
A=+102.8'
REV4
A-5: BUILDING SECTIONS, WALL SECTIONS, DETAILS
REV5
B=+104.5
C=+105'
do 0 M■■■■■
■■■01
D=+107.8'
I
S1: STRUCTURAL NOTES
TOTAL=+420.1'
Please obtain a separate plumbing permit from
AVERAGE GRADE = 420.1/4=105.025
City ofEdmonds.
S2: FOUNDATION & ROOF FRAMING PLANS
Ithe
PROPOSED MAXIMUM HEIGHT: 123.935'
ALLOWED MAXIMUM HEIGHT: 130.025' �'
"'
S3: STRUCTURAL DETAILS
i
co
ORK SUBJECT
O FIELD
S ECTION FOR
COMPLIANCE
PPROVED
P
NS MUST BE
O
JOB SITE
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
ENGINEERING DIVISION
APPROVED AS NOTED
05/18/2023
VV
RESUB
May 16 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2023-0027
o �
S N'z
z
I�
0
� w a �
z
c7U�
0 4 >1
x
�W
o " H
0
Lo 1:
0
w N
00 � I-_
=0
LiX
N Z Q s
U Lu 6
w a cn
Zp 1:w s
- = � U
-� 0_ J J
DATE PLOTTED
4/25/2023
SCALE
varies
FILE NAME
Hill plan c
SHEET
A-1
ALLEY 76.131
15' rear setback
gas
' I
I I
I I
I I
I I
� I
I I
I I II I
I , I
I �
I I
, I I
, I
I I
I I I� I
I , I
I I
I I
I I
t�
I
I I
I I
I I I
I I
I
I w I I
I I
I
I
I I
-------------------------------
I '
Remove I
I '
garage door
I I
I I
Remove man I
door
I I
I I
' I III \
--------
L i
L '— J
I
I_ I
I I
I
I
I
I I
1 '
Remove
portion of
sidewalk i
00 \
EXISTING
& Demolition
I I \ \
I I \ \
Remove r i 14'-2"
I
stairs _, -IF ------rT
------------------
11
T- rr=----- ---------------------�
1--------- `
-------_�___________________col I \
I;I ;II ICI III \ Remove portion of driveway
I III u I gllh I \
REMOVE ENTIRE "II;
NORTHEAST T
u u ADDITION
I u of I
I I l l u I u o l I \
I I l l u I u o l I \
I I l l u I u l u I \
III a II a lu I �\
II III I
0o III ,II I
BEDRM 1
I I
IIII
I \ I gllq I \
I III II II I I II III I
I
III II II
III II II
, Illu Ili i I
u
_ I III II 11FLL====_____________-
_
__-1 __ _� II
II ,I
II , III a II III I � � p II
u pII
III``---------
r— a -- ---____
Replace III r�---- --
u
-- - _ -- /
----_�__—_ H -- - --'- IL--}- --
Replace cFF@0
windows.
T \\ Remove =
zD
W walls & - - -
Remove
; ;I \ `\ `, fixtures @ 'I /
closet. _ master bath.
Remove L \ _---_--� / 1, /
portion of +�� \- - - - - -
,�-I III ,I
west wall
for new --------------------------- - - - - --
_
window.
--t--.�------- --o ° Im III II � \
F------
Replace
c
------
north
window. `--------------
\--J
Im
_ \
\ / enlarge Remove
cased F laundry closet. \
I
opening.
Li
III'
I
I ,
Remove low
walls& / \ BEDRM 2 Replace I
I I
windows.
Remove window I dividing wall. / \ I
& portion of wall ; / \ ;'
I
L
/
Replace \ Replace
n \ windows.
windows.
-------- --
5'
20' front setback
--------------
--------------
76.13' ALDER STREET
U
Q)
0
v,
M, i
ALLEY 76.13'
15' rear setback
F- I
I I
I
I I
I
I �
II
I , I
, I I
I
I I I I
I �
I
II II I , I
I I
I
I I —�
I
I I
I
---------------------------------------------------------------
I
w
GF
I I
I I
GARAGE I Electric Vehicle Parking:
I Existing outlets, Fully wired circuit w/
lights, switches to level 2 or level 3 EV
remain. charging receptacle
outlet including conduit
To existing & wiring & capacity
garag Its req'd to allow for
installation of EV
�■—■—■—■—■—■—■—■—■—■—■� I charging station.
I ■ I I
Separation of the two structures are to be as pert
Structural Engineers calculations. please see
istructural page dated 4/25/2023. that has been eW
reviewed by the City of Edmonds. I 368
■ I exterior
■ door 220 V. 48A EV
�p -0•77— Existing elect. WP GFCI arge_Close off existing garage door and man door.
panel _ _
-
--- - -------------------- - - - - -- o O rl
O
r-I
New 3680 LAU B Hybrid
tier 3 M U D R00 M New
ELECTRICAL LEGEND ' s 34lite w UEF .0 3680
A-5 A-5 m ext&e for door 2 9
WALL SWITCH slab ins _ „
C 3 3'-5" f xn 3 5 34 12 3 oerior ST00 &0 „
SWITCH WITH DIMMER min50 fm 11 U) FONT
DIM 10, D IVEWAY C
roof as senn �- cil
P
{} CEILING LIGHT J-BOX TYPE TBD n, O.H. - `r'
FAN/LIGHT COMBO -? f f i oo High ' _ 6
o +0" _ o o - ---- --- -- storage r -5
(open
WALL LIGHT FIXTURE G CI x UP gfci vent
4 Exhaust fan shelving)
A-5 to min 50 above _
CEILING LIGHT- PENDANT 5 H &
stair N N
CEILING HEAT LAMP - ON TIMER o to v A-5 30" pkt Wsr/Dryer 11 r,
m A-4 M w
" P WATERPROOF EXHAUST FAN handrail�31
+42gfci
EXHAUST FAN - NO LIGHT �' 0" tubul r 1
w ter r roof
= cas d - skylit
I?ope ing m O.H.
O
CEILING FAN LIGHT TBD PROPOSED FLOOR PLAN M M b h 1 A 5
3
a, linen VAULT I I G
wall
D CIOSet Cgfcl D
un
DUPLEX OUTLET - STD. BASEBOARD HEIGHT BEDRM 1
30" b f. B VAULT CEILING
=
4):DUPLEX OUTLET- GROUND FAULT CIRCUIT INTERUPT
GFCI CD
to
WP DUPLEX OUTLET- WEATHERPROOF
Vi 3' 5' 5'-5" m
A-5 QI 3
+4 DUPLEX OUTLET -SPECIFIED DISTANCE ABOVE FIN. FLR. wall `- 11
11 30" pkt Ln
Ln
DUPLEX OUTLET IN FLOOR o WP
FLR C,
M c
o/cozloset
i sSMOKE & CO2 DETECTOR - HARD WIRED & INTERCONNECTED 3 VAULT CEILING
v
c
------- UNDER CABINET LIGHT Fro �I '
under cab It � N
_ 0 -
p U o0
d NETWORK CONNECTION o
M L
BEDRM 4
M 48" bi-fold
WALL PLATE CO-AX CABLE OUTLET 1111 FLAT CEILING
coo-ax
_ _ _ 2248 attic =
-- -- -
WALL PLATE USE; OUTLET 1D 5� access' 51 �I _j
M
USB MvFCI 3'-10" 3-_3- 5':; 2'-1" 5!, 2'-7"; 12' 10" a,
in _
41 c-I
= lfl bUlt-I �
Ex tfan helvi
Whole -house mechanical N
ventilation system per M1505.4 g min so c A 5 ^ 6
consisting of one or more C, _ -5
exhaust fans, or an ERV/HRV a3�, tempered s er f ent
with integral fans, associated 6448 -DH window � "' g
ducts and controls.
-5
Whole house Exhaust fans. 2 double hung 2848 ° ° skblul r - % a Exha stfa all
replacement windows field verify r - X - - - o min 5 cf l
Exhaust fans required shall be l� �n bath 2 �'
ducted directly to the outside. tubl tubular
KITCHEN \ \ T CEILING =
Exhaust air outlets shall be -
designed to limit the pressure w NO CHANGE ----- - -----------------------------
Existing outlets, lights, +42'
difference to the outside and gfci bull I CIOSet l'
switches to remain. = r
equipped with backdraft v ` \ Ln shel ing
dampers or motorized dampers E "> OFFICE / FLEX SPACE \ - 8' bi-pass U
in accordance with the ��—�, -_T�-�-____-- _________________ " 2'-3" 2'-5" 5 1'6" -7" 5' _
Washington State Energy Code. 3 104 sf 000 `" FLAT CEILING O FI
The system shall be designed o \
00-a \ To existing' M - BEDRM 3 a--� and installed to exhaust and/or c
- -- lights Increase
�o ? Existing outlets, ` - - - - - - - - - - - g wP
supply 65 cfm. The whole house \ cased Q,�
lights, switches to \
ventilation system shall be E remain. \ / GF
opening to (%)
U configured with intermittent off 6' wide \
('6 controls per Section \ / Q)
M1505.4.3.2. Design and \ / ,, \ =
installation of the system or -I
Y New interior�n \ Exis g outlets, n rl
�"� equipment shall be carried out in \ / doors to be \ o
Q� accordance with manufacturers' �n lights, witcnesto
gas \ / u.n'.o.80 FLATCEILING� remain. bath 3 3
(/) installation instructions. Whole IJ -
\ / NO CHANG
house ventilation fans shall be - F_ "'
rated for sound at a maximum of N
1.0 sone. The whole house \ / To existing o BEDRM 2 \
. — supply fan shall provide ducted \ / lights
V) outdoor ventilation air to each
_ habitable space within the - -
residential unit. o / \ Existing outlets, /
/ \ lights, switches to / 10IJLn
D
� remain.
/ 1'-10' / \ / roof
O.H.
LIVING ROOM
/ \ / ew3661-D
Q 0
F,r+'n � *lets, � � \ O =
lights, switches to / \ 3 '-4" 3' 4'-5" o O
FC remain. _
New
heat
pump
ins
min. 9.5 / \
HSPF I =J 8460 replacement _
window field verify \
° Existing entry door / sidelites to remain 2 ou e ung w top mu ions °
V 36" x 60" windows
E
6' 3'-4"
A
20' front setback
-----------------------------
76.13' ALDER STREET
N
W
Field
verify.
Garage
& house
not
perfectly
parallel.
-III
I
I
I
PROPOSED -FLOOR PLAN 1/4It = 111-0"
i
i
Drawings and the
associated cad files
are considered
'instruments of
service' and may not
be used for any
other project or for
any addition to this
project or for
completion of
drawings by others.
All rights reserved.
BLD2023-0027
RESUB
May 16 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
O
�
S
� �
z
O
H
P4w >~E_
E� z
C7 U
ro 3
C O
N a w
Ln �
0
H
w N
00 � ~
00 0
(D X
N z Q s
w
w Q N 6
Zp w s
11 J J
DATE PLOTTED
4/25/2023
SCALE
varies
FILE NAME
Hill plan c
SHEET
A-2
EXISTING FRONT (SOUTH) ELEVATION
L 1 i ii
EXISTING NORTH GARAGE ELEVATION L
EXISTING SOUTH GARAGE ELEVATION
L _ i I
1 i ii
EXISTING NORTH ELEVATION WITHOUT GARAGE L
I ------
Drawings and the
associated cad files
are considered
'instruments of
service' and may not
be used for any
other project or for
any addition to this
project or for
completion of
drawings by others.
All rights reserved.
BLD2023-0027
RESUB
May 16 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
�
L
S
�
0
-7�
z
C
�W c�
z
�¢�x3
-oo
zW
o " H
o n
Lo
—
37
o
F-
��
w
~
N
C
00
00
O
N
Z
Q
s
U
LLI
6
Lu
ZO
a
cn
LLI
S
-
—�
=
0-
J
U
J
DATE PLOTTED
4/25/2023
SCALE
varies
FILE NAME
Hill plan c
SHEET
EXISTING WEST ELEVATION
A-3
Required handrails shall be of one of the following types or provide equivalent graspability.
Type I. Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches (32 mm) and not greater than 2
inches (51 mm). If the handrail is not circular, it shall have a perimeter dimension of not less than 4 inches (102 mm) and not greater than
61/4 inches (160 mm) with a cross section of dimension of not more than 2-1/4 inches (57 mm). Edges shall have a radius of not less than
0.01 inch (0.25 mm).
Type II. Handrails with a perimeter greater than 6-1/4 inches (160 mm) shall have a graspable finger recess
area on both sides of the profile. The finger recess shall begin within a distance of 3/4 inch (19 mm) measured vertically from the tallest
portion of the profile and achieve a depth of not less than 5/16 inch (8 mm) within 7/8 inch (22 mm) below the widest portion of the profile.
This required depth shall continue for not less than 3/8 inch (10 mm) to a level that is not less than 13/4 inches (45 mm) below the tallest
portion of
the profile. The width of the handrail above the recess shall be not less than 11/4 inches (32 mm) and not more than 2314 inches (70 mm).
Edges shall have a radius of not less than 0.01 inch (0.25 mm)
PROVIDE CONTINUOUS
HANDRAIL ON AT LEAST ONE
SIDE @ ALL STAIRS WITH 4 OR
MORE RISERS
1)/2" HANDRAILS SHALL BE
min CONTINOUS FROM A POINT
DIRECTLY ABOVE THE TOP
RISER TO A POINT DIRECTLY
4Y2„ C ABOVE THE LOWEST RISER
max THE USE OF A VOLUTE,
TURNOUT OR EASING IS
PERMITTED ABOVE THE LOWEST
STAIR
HANDRAIL ENDS SHALL BE
RETURNED OR TERMINATED IN
SAFETY TERMINALS
HANDRAILS AND GUARD RAILS
TO WITHSTAND A 200 LB
CONCENTRATED LOAD APPLIED
AT THE TOP OF THE RAIL
MIN & MAX DIMENSIONS AS
SHOWN
H n D ^ ^ SEE CONNECTIONS
ENG DETAILS FOR
\vl K /(�\ CONNECTIONS
1 D6 HANDRAIL SEE STAIR DETAIL FOR TREADS 1
AND RISERS //
N
30.64'
105.64'
u�
N
30.64'
Maximum allowed Height = 130.64'
+123.97'
130.64'
Maximum allowed Height = 130.64'
+123.97'
MAXIMUM ACCESSORY HEIGHT
N — RAISED HEEL TRUSS
TOP OF PLATE - EXISTING
08'-0" FLOOR - HOUSE
00 Average grade = 105.64'
105.64'J105'
_ FLOOR - MUDROOM
-2-3/4" FLOOR - GARAGE
Replacement windows
Existing entry door / sidelites to remain
PROPOSED FRONT (SOUTH) ELEVATION
Replacement windows
I
I
I
I
I
I
I
I
new 3660-DH
I
I
I
ave
f
addition
within 5' of
property
line to be 1
hour
fire -rated
10"
Eave of addition
— MAXIMUM ACCESSORY HEIGHT 6:12 Eave of within 5' of existing
o addition garage roof to be 1
within 5' of hour fire -rated
property
line to be 1
hour
RAISED HEEL TRUSS fire -rated
�— TOP OF PLATE - EXISTING
BO
t71
108'-00 FLOOR - HOUSE
Average grade = 105.64'
N
_105 4' 105'-4" FLOOR - MUDROOM
105'-2-3/4" FLOOR - GARAGL
Maximum allowed Height=130.64'
MAXIMUM ACCESSORY HEIGHT
RAISED HEEL TRUSS
TOP OF PLATE - EXISTING
108'-o FLOOR - HOUSE
Average grade = 105.64'
105'-4" FLOOR - MUDROOM
105'-2-3/4" FLOOR - GARAG-E—
Ln
N
new 4661-DH
EGRESS
new 4661-DH
EGRESS
new 4661-DH
EGRESS
new 3660-DH
new 3660-DH
EGRESS
30.64'
+123.97'
0
Maximum allowed Height = 130.64'
existing
North wall @ addition
to be 1 hour fire -rated
PROPOSED WEST ELEVATION
O 0 0 0 0 0 0 0
ext.
door
2'
GAP
Eave of addition
within 5' of existing
garage roof to be 1
hour fire -rated
It'
IN
PROPOSED EAST ELEVATION
0
North wall @ addition
to be 1 hourfi -rated
ite
PROPOSED NORTH GARAGE ELEVATION L
L _ � II II II
new new
36"x60" 36"x60"
dh dh
L�J
r_J
r_J
O 0
IF
new new
36'x60" 36"x60"
dh dh
new
36"x60"
dh
L I
r"
I
I
6448 double hung
III O �titi
eg
existing
o
PROPOSED - ELEVATIONS 1/411 = 1'-011
existing
6:12
6448 doi ble hung
Drawings and the
associated cad files
are considered
'instruments of
service' and may not
be used for any
other project or for
any addition to this
project or for
completion of
drawings by others.
All rights reserved.
BLD2023-0027
RESUB
May 16 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
�
L
S
�
O
�
z
r~
C
W4
�� z
�U�
1,4¢�x3
-go
C W
a
o F
Lo
O
h� U
`0 LU N
00 ~
00
,^ = O
V
N Z Q s
w
w in
a fn
Zp Lu s
- = U
IL J J
DATE PLOTTED
4/25/2023
SCALE
varies
FILE NAME
Hill plan c
SHEE
A-4
SEE ENGINEERING DRAWINGS FOR FRAMING
SIZES AND DETAILS AND NAILING.
R-10 RIGID INSUL
Install all insulation
materials per,
PROTECTIVE COATING APPROVED
manufacturer s
specifications
BY RIGID INSULATION MANUFACTURE
FLASHING
TIGHTLINE
ZZ
DOWNSPOUT
PRESSURE TREATED MUDSILL
SEAL ALL CRACKS & JOINTS
z
SILL SEAL & CAPILLARY BREAK
CONCRETE SLAB ON GRADE
4" PERE. DRAIN
°
TIE TO EXIST
TIGHT LINE N
SYSTEM
%LRADON/MOISTURE BARRIER
R-10 RIGID INSUL
°a <
SEE ENGINEERING PLANS FOR FOOTING
DIMENSIONS & CONC REINFORCEMENT
SLAB ON GRADE `
1
3/4" = V— <
D H L P L
OF SUPPORTING A 300 LB SEE STRUCT ENG DETAIL
LOAD @ ANY POINT FOR CONNECTIONS
MIN. TREAD WIDTH = 36".
HANDRAILS MAY PROJECT
1-1/2" INTO WIDTH
MIN. TREAD DEPTH = 10"
�y
MAX. TREAD HEIGHT = 7.75"
PROVIDE CONTINUOUS
HANDRAIL OR TERMINATE @
NEWEL POST OR SAFETY
4'
TERMINAL
MAX
�z
HANDRAILS AND GUARD RAILS
M
4^
TO WITHSTAND A 200 LB
MAX
CONCENTRATED LOAD
APPLIED AT THE TOP OF THE
RAIL
INFILL COMPONENT TO
x
WITHSTAND A 50 LB LOAD
1
APPLIED OVER A 12"X12" AREA
MIN.
GLASS ELEMENTS TO BE
3/4" — 1-1/4°
DESIGNED WITH A SAFETY GUARDRAIL
�
nosing req'd for
FACTOR OF 4 (per SBC REQ'D WHERE
treads < 11°
2407.1.1)
DECK SURFACE
IS >/_ +30
MIN & MAX DIMENSIONS AS
ABV GRADE OR
3/8" MAX VARIATION IN
SHOWN
FIN ELF
RISER & TREAD DIMS.
STAIRS
& GUARDRAILS
/ d6stair.DWG 1./2" = 1'-0"
SEE DET #1 ON A-4 FOR HANDRAIL
SEE ENGINEERING DRAWINGS FOR FRAMING
SIZES AND DETAILS AND NAILING.
RAISED HEEL PLATED SCISSORS TRUSS
ROOFING \
ROOF SHEATHING
VAPOR BARRIER—,
FLASHING TO BE
NSTALLED IN A MANNER
THAT PREVENTS
MOISTURE FROM
ENTERING
GUTTER
FIRE & EMBER SAFE
3.5x22 LAVE VENT
INSTALLED PER MFR
INSTR. (min.15
vents @ addition)
1 HOUR FIRE RATED
FIBER CEMENT
BOARD. HARDIE
PANEL OR OTHER.
ROOFING TO BE
ASPHALT SHINGLES OR
METAL ROOFING WITH
APPROVED
UNDERLAYMENT
@SHEADERISAL
)UUULL
CUT EXISTING
GARAGE ROOF
OVERHANG
HARDIE PANEL SIDING
FLUSH WITH
FACE OF SOUTH
GARAGE WALL
WALL SHEATHING
R-21 BATT INSUL
5/8" GWB
NEW HARDIE
PANEL @
SOUTH FACE
OF EXISTING
GARAGE WALL
6"-12'
2x6 STUD WALL
gap varies
AIR FLOW TO
CONTINUOUS
RIDGE VENT -
SEPARATION @ GARAGE
SHOWER
D8shower.DWG
GLASS PANEL
CERAMIC OR MARBLE SLAB
CEMENT BACKER BOARD
WALL STRUCTURE
Z FLASHING
ONE-PIECE READY TO TILE
SHOWER PAN WITH
THINSET CONCRETE
FLOOR STRUCTURE
R-38 BATT INSULATION
DO NOT COMPRESS
BAFFLE TO MAINTAIN AIR SPACE
5/8" GYP WALL BOARD
WALL SHEATHING
WALL FRMG 2x6 STUDS @ 16" O.C.
R-21 FACED BATT INSUL
SIDING TO MATCH EXISTING
VAPOR RETARDER
R10 RIGID INSUL
PROTECTIVE COATING
APPROVED
BY RIGID INSULATION
MANUFACTURER
FLASHING
PVC TRIM BOARD
3/4" SHEATHING & FLOOR
VAPOR RETARDER
UNFACED BATT INSUL
R-30
INSUL. SUPPORTS @
24" O.C.
r0SEE ENGR.
FOR SUBFLOOR
1" = 1'-0"
All insulation to be installed per manufacturer's
instructions
Completely fill all exterior wall cavities and insulate to the
full required R-Value. Exterior wall cavities are considered
to be any wall separating a heated space from an
unheated space. This includes but is not limited to:
• Behind shower/tub enclosures on exterior walls
• Where interior and exterior walls meet and at exterior
corners
• Stairwells to unheated basements
• Skylite chases through attics Also see:
WSEC
Builder's Field
Guide for more
exterior interior wall wall framing
corner intersection and insulation
Do not compress insulation behind options and
details
electrical boxes or around pipes
INSULATION
D4EXTINSUL .DWG
FI MR OR CEILING FRAMING
R LAUNDRY EXHAUST FAN MIN. 50 CFM ON TIMER SWITCH
i-Si
NITS
5/8" GYP WALL BOARD
WALL SHEATHING
WALL CAP WITH DAMPER & SCREEN
LOCATE WALL CAP MIN. 10' FROM ANY AIR INLET
BATH OR LAUNDRY VENT
D11exhaustfan.DWG
SEE ENGINEERING DRAWINGS FOR FRAMING
SIZES AND DETAILS AND NAILING.
RAISED HEEL PLATED SCISSORS TRUSS
ROOFING \
ROOF SHEATHING
VAPOR BARRIER—,
FLASHING TO BE
INSTALLED IN A MANNER
THAT PREVENTS
MOISTURE FROM
ENTERING
GUTTER
FIRE & EMBER SAFE
3.5x22 LAVE VENT
INSTALLED PER MFR
INSTR. (min.15
vents @ addition)
1 HOUR FIRE RATED
FIBER CEMENT
BOARD. HARDIE
PANEL OR OTHER.
ROOFING TO BE
ASPHALT SHINGLES OR
METAL ROOFING WITH
APPROVED
UNDERLAYMENT
z_
QD
@SHEADERISAL
1" = 1'-0"
AIR FLOW TO
CONTINUOUS
RIDGE VENT -
MIN. 1 " AIR SPACE
TO RIDGE VENT
BAFFLE TO MAINTAIN AIR SPACE
R-49 BATT INSULATION
DO NOT COMPRESS
5/8" GYP WALL BOARD
WALL SHEATHING
WALL FRMG 26 STUDS @ 16" O.C.
R-21 FACED BATT INSUL
SIDING TO MATCH EXISTING
VAPOR RETARDER
R10 RIGID INSUL
PROTECTIVE COATING
APPROVED
BY RIGID INSULATION
MANUFACTURER
FLASHING
PVC TRIM BOARD
3/4" SHEATHING & FLOOR
VAPOR RETARDER
UNFACED BATT INSUL
R-30
INSUL. SUPPORTS @
24" O.C.
SEE ENGR.
FOR SUBFLOOR
PRESSURE TREATED MUDSILL ° ° PRESSURE TREATED MUDSILL
SILL SEAL & CAPILLARY BREAK SILL SEAL & CAPILLARY BREAK
- ° a FOUNDATION VENT (1 sf PER 150 sf) - ° a FOUNDATION VENT (1 sf PER 150 sf)
BLOCK TO SECURE MOISTURE BARRIER 4BLOCK TO SECURE MOISTURE BARRIER
00 ° 00 °
a ° 6 MIL MOISTURE BARRIER a ° � 6 MIL MOISTURE BARRIER
4" PERF. DRAIN ° a ° 4" PERF. DRAIN
TIE TO EXIST ° a SEE ENGINEERING PLANS FOR FOOTING ° a SEE ENGINEERING PLANS FOR FOOTING
TIGHT LINE ° "IMEN&ONS & CONC REINFORCEMENT TIE TO EXIST ° 4 DIMENSIONS & CONC REINFORCEMENT
SYSTEM TIGHT LINE
SYSTEM
WALL SECTION @ Vaulted ceiling 1" = 1'-0" WALL SECTION @ Flat ceiling 1" = 1'-0"
7 -
1 8 HOUR FIRE RATING 1 HOUR FIRE RATING
existing
truss roof Cut existing gara
structure to overhang flush wi
remain
existing
existine slab on erade &
footings to remain
Raise ceiling
@ window seat
LIVING ROOM
Window Seat
� o en shvs
BB
BASEMENT
BUILDING SECTION EE
SEE ENGINEERING DRAWINGS FOR FRAMING
SIZES AND DETAILS AND NAILING.
RAISED HEEL PLATED SCISSORS TRUSS
ROOFING
ROOF SHEATHING
VAPOR BARRIER—\
FLASHING TO BE
INSTALLED IN A MANNER
THAT PREVENTS
MOISTURE FROM
ENTERING
GUTTER
EAVE VENT
INSTALLED PER MFR
INSTR. (min.15
vents @ addition)
ROOFING TO BE
ASPHALT SHINGLES OR
METAL ROOFING WITH
APPROVED
UNDERLAYMENT
@SHEADERISAE
1
4" PERF. DRAIN
TIE TO EXIST
TIGHT LINE
SYSTEM
WA
9
AIR FLOW TO
CONTINUOUS
RIDGE VENT -
OFFICE
MIN. 1 " AIR SPACE
TO RIDGE VENT
BAFFLE TO MAINTAIN AIR SPACE
R-49 BATT INSULATION
DO NOT COMPRESS
1/2" GYP WALL BOARD
WALL SHEATHING
WALL FRMG 2x6 STUDS @ 16" O.C.
R-21 FACED BATT INSUL
SIDING TO MATCH EXISTING
VAPOR RETARDER
R10 RIGID INSUL
PROTECTIVE COATING APPROVED
BY RIGID INSULATION MANUFACTURER
FLASHING
PVC TRIM BOARD
3/4" SHEATHING & FLOOR
VAPOR RETARDER
UNFACED BATT INSUL R-30
INSUL. SUPPORTS @ 24" O.C.
SEE ENGR. FOR SUBFLOOR
00
_"ii
PRESSURE TREATED MUDSILL
SILL SEAL & CAPILLARY BREAK
FOUNDATION VENT (1 sf PER 150 sf)
A °
BLOCK TO SECURE MOISTURE BARRIER
°
� a ° � 6 MIL MOISTURE BARRIER
° a SEE ENGINEERING PLANS FOR FOOTING
DIMENSIONS & CONC REINFORCEMENT
LL SECTION @ Flat ceiling 1" = 1'-0"
PROPOSED - BUILDING SECTIONS 1/4" = 1'-0"
Eave of
addition
within 5' of
property
line to be 1
hour
fire -rated
_
o
�
-
-
High cupboard
Water heater closet
Floor structure
Storage cupboards under floor
--------------------------- -- ----------I-
--------------------------- - -- ----------I-
El EEI
Stairs up
to
window
lined
hall
----
to
bedrm
2
LLLLLLI
LLLLLL0
I L��L�� I
I�L��LLI
L -----J
---------------
---- ----
rNN
130.64'
in
Maximum allowed Height = 130.64'
MAXIMUM ACCESSORY HEIGHT
N RAISED HEEL TRUSS
TOP OF PLATE - EXISTING
zo
11, 108'-o" FLOOR - HOUSE
Average grade = 105.64'
64' N 105'-4" FLOOR - MUDROOM
105'-2-3/4" FLOOR -GARAGE
repla ment
new wi ow
64" x 48" fiel erify
window
existing
door
to
remain
_ existing
- II
BUILDING SECTION CC L
II
PROPOSED NORTH ELEVATION WITH SECTION THROUGH NEW LAUNDRY / MUDROOM TOWARD HOUSE
N
.64'
Maximum allowed Height=130.64'
MAXIMUM ACCESSORY HEIGHT
N RAISED HEEL TRUSS
TOP OF PLATE- EXISTING
in
FLOOR - HOUSE
bo Average grade = 105.64'
64' N 105' 4" FLOOR - MUDROOM
105'-2-3/4" FLOOR - GARAGE
BUILDING SECTION DD
f
1
Drawings and the
associated cad files
are considered
'instruments of
service' and may not
be used for any
other project or for
any addition to this
project or for
completion of
drawings by others.
All rights reserved.
BLD2023-0027
RESUB
May 16 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
o
�
O
_7�
s
�
z
0
�
W ~�
W4 E. z
�U�
4¢�x3
C W
a
o F
Ln
0
`I - w N
00 1: ~
°° = O
N Z a s
W
� w a Nin �
Zp w s
- = Y U
0— __J J
DATE PLOTTED
4/25/2023
SCALE
varies
FILE NAME
Hill plan c
SHEET
A-5
GENERAI STRIIC:TIIRAI NOTES
(The following apply unless shown otherwise on the plans)
THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE
ALL CONNECTIONS/FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED OR FIRE -RETARDANT -TREATED WOOD, SHALL BE OF
INTERNATIONAL BUILDING CODE. SUBSTITUTIONS SHALL HAVE CURRENT ICC-ES APPROVAL.
HOT DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL. HOT DIPPED GALVANIZED FASTENERS SHOULD CONFORM
CRITERIA
TO ASTM STANDARD 153, AND HOT DIPPED GALVANIZED CONNECTORS SHOULD CONFORM TO ASTM STANDARD A653 (CLASS G-
A. CONCRETE ANCHORS
185). STAINLESS STEEL FASTENERS AND CONNECTORS SHOULD BE TYPE 304 OR 316. NOTE: ELECTROPLATED GALVANIZED
1. ALL MATERIALS WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE
1. MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR
FASTENERS AND CONNECTORS ARE NOT TO BE USED WITH PRESSURE TREATED WOOD. SIMPSON PRODUCT FINISHES
2018 INTERNATIONAL BUILDING CODE (IBC) INCLUDING WASHINGTON STATE MODIFICATIONS.
USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193. PRE -APPROVED MECHANICAL ANCHORS INCLUDE:
CORRESPONDING TO THE ABOVE REQUIREMENTS ARE ZMAX (HOT DIPPED GALVANIZED) AND SST300 (STAINLESS STEEL).
a. SIMPSON STRONG -TIE "STRONG -BOLT 2" (ICC-ES ESR-3037)
STAINLESS STEEL HARDWARE AND FASTENERS SHALL NOT BE COMBINED WITH UNTREATED OR GALVANIZED MATERIAL.
2. DESIGN I DARING CRITERIA
b. SIMPSON STRONG -TIE "TITEN-HD" (ICC-ES ESR-2713)
SNOW LOAD ROOF SNOW LOAD, Pf = 25 PSF
c. HILTI "KWIK BOLT TZ" (ICC-ES ESR-1917)
IMPORTANCE FACTOR, Is = 1.0
27. WOOD FASTENERS:
EXPOSURE FACTOR, Ce = 1.0
2. ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR
THERMAL FACTOR, Ct = 1.0
USE IN ACCORDANCE WITH ICC-ES AC308. PRE -APPROVED ADHESIVE ANCHORS INCLUDE:
A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS:
SLOPED ROOF FACTOR, CS = 1.0
a. SIMPSON STRONG -TIE "SET-XP" (ICC-ES ESR-2508)
b. SIMPSON STRONG -TIE "SET-3G" (ICC-ES ESR-4057)
SIZE LENGTH DIAMETER
FLOOR LIVE LOAD (RESIDENTIAL) 40 PSF
c. SIMPSON STRONG -TIE "AT-XP" (IAPMO UES ER-263)
6d 2" 0.113"
d. HILTI "HIT -RE 50043" (ICC-ES ESR-3814)
8d 2-1/2" 0.131"
WIND (MAIN WIND FORCE RESISTING SYSTEM) BASIC WIND SPEED = 97 MPH
e. HILTI "HIT-HY 200" (ICC-ES ESR-3187)
10d 3" 0.148"
ALLOWABLE STRESS DESIGN WIND SPEED = 75 MPH
12d 3-1/4" 0.148"
IMPORTANCE FACTOR, Iw = 1.0
won
16d 3-1/2" 0.162"
RISK CATEGORY = II
TOPOGRAPHIC FACTOR, Kzt = 1.0
18. FRAMING LUMBER SHALL BE KILN DRIED OR MC-19, AND GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD
DESIGN IS BASED ON COMMON STEEL WIRE NAILS MEETING THE REQUIREMENTS OF ASTM F1667. USE OF ALTERNATE
EXPOSURE CATEGORY = B
GRADING RULES FOR WEST COAST LUMBER NO. 17, LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS.
FASTENERS MUST BE SUBMITTED FOR REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER PRIOR TO THE START OF
INTERNAL PRESSURE COEFFICIENT, (GCpi)= 0.18/-0.18
CONSTRUCTION.
WIND BASE SHEAR (N/S) = 4.49 KIPS
JOISTS: HEM -FIR NO. 2
WIND BASE SHEAR (E/W) = 2.80 KIPS
(2X, 3X, AND 4X MEMBERS) MINIMUM BASE VALUE, Fb = 850 PSI
B. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING
WITH NO COUNTERSINKING PERMITTED.
EARTHQUAKE (EQUIVALENT LATERAL FORCE PROCEDURE) Ss = 1.285
RFAM ANn STRINGERS: DOUGLAS FIR LARCH NO. 1
Sds = 1.028
(6 X AND LARGER MEMBERS) MINIMUM BASIC DESIGN STRESS, Fb = 1,350 PSI
S1 = 0.452
28. WOOD FRAMING NOTES - THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS:
Sd1 = 0.557
P()STS ANn TIMBERS: DOUGLAS FIR LARCH NO. 1
IMPORTANCE FACTOR, le= 1.0
(6 X AND LARGER MEMBERS) MINIMUM BASIC DESIGN STRESS, Fb = 1,200 PSI, FC = 1,000 PSI
A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE
SITE CLASS D
INTERNATIONAL BUILDING CODE. MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.10.1 OF
SEISMIC DESIGN CATEGORY= D
STUDS PLATES & MISCELLANEOUS LIGHT FRAMING DOUGLAS FIR LARCH OR HEM -FIR NO. 2,
THE INTERNATIONAL BUILDING CODE. UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE AS SPECIFIED ABOVE.
RISK CATEGORY = II
MINIMUM BASIC DESIGN STRESS Fb = 850 PSI, FC = 1,300 PSI
COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE
R = 6.5 FOR WOOD STRUCTURAL PANEL SHEAR WALLS
WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. INSTALLATION OF BOLTS
OVER STRENGTH FACTOR, Do = 3.0
19. LAMINATED STRAND LUMBER (LSL): EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT NUMBER OF
AND LAG SCREWS SHALL CONFORM TO SECTIONS 12.1.3 AND 12.1.4 OF THE 2018 NATIONAL DESIGN SPECIFICATION FOR
DEFLECTION AMPLIFICATION FACTOR, Cd = 4.0
THE MANUFACTURER, THE GRADE, PRODUCT DESIGNATION OR TYPE, THE PRODUCTION DATE, SPECIES OR SPECIES GROUP
WOOD CONSTRUCTION. NATURALLY DURABLE OR PRESSURE TREATED WOOD SHALL BE PROVIDED WHERE REQUIRED BY
REDUNDANCY FACTOR = 1.0
DESIGNATION, AND THE QUALITY CONTROL AGENCY. MEMBERS SHALL BE GLUED WITH A WATERPROOF ADHESIVE MEETING THE
SECTION 2304.12 OF THE INTERNATIONAL BUILDING CODE.
SEISMIC RESPONSE COEFFICIENT, Cs = 0.158
REQUIREMENTS OF ASTM D2559 WITH ALL GRAIN PARALLEL WITH THE LENGTH OF THE MEMBER. STRUCTURAL CAPACITIES SHALL
SEISMIC BASE SHEAR = 9.5 KIPS
BE ESTABLISHED IN ACCORDANCE WITH ASTM D5456 AND PRODUCT SHALL HAVE AN APPROVED ICC-ES EVALUATION REPORT.
B. WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2X6 AT 16" O.C. TWO STUDS MINIMUM
MEMBERS SHALL BE TRANSPORTED AND STORED PER MANUFACTURERS RECOMMENDATIONS AND SHALL NOT BE EXPOSED TO
SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS. TWO 2 x 8 HEADERS SHALL BE
RAIN INTENSITY 1.0 INCHES/HOUR
PROLONGED MOISTURE. MINIMUM REQUIRED DESIGN PROPERTIES: Fb = 2325 PSI, Fv = 310 PSI, E = 1,550,000 PSI,
PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED AND SHALL BEAR FULLY ON A MINIMUM OF TWO STUDS. SOLID
BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE SOLID
3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION.
LSL RIM JOISTS SHALL CONFORM TO ANSI/APA PRR 410 AND SHALL BE MARKED IN ACCORDANCE WITH THE STANDARD.
BLOCKING BETWEEN STUDS AT MID -HEIGHT OF ALL STUD WALLS OVER 10, IN HEIGHT.
CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE INTENDED FOR
DESIGN SHOWN ON PLANS IS BASED ON LUMBER MANUFACTURED BY WEYERHAEUSER. ALTERNATE MANUFACTURERS MAY BE
STUDS MAY BE NOTCHED, CUT, OR PENETRATED WITH ROUND BORED HOLES AS FOLLOWS:
REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS.
USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER, ALTERNATE JOIST HANGERS AND
OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER
STUD SIZE MAXIMUM NOTCH / CUT MAXIMUM BORED HOLE
4. CONTRACTOR SHAI L PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL
LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH MEMBERS PROVIDED.
2X4 7/8" 1-3/8"
CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS.
2X6 1-3/8" 2-1/8"
20. PREFABRICATED OPEN WER WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER FOR THE SPANS AND CONDITIONS
5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES, OR
SHOWN ON THE PLANS AND SHALL BE FURNISHED AND INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED
BORED HOLES SHALL NOT BE LOCATED WITH 5/8" FROM THE EDGE OF THE STUD OR AT THE SAME LOCATION AS A NOTCH
PROCEDURES REQUIRED TO PERFORM THE WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY
SPECIFICATIONS. ALL NECESSARY BRIDGING, BLOCKING, PRE -NOTCHED PLATES, ETC. SHALL BE DETAILED AND FURNISHED BY
OR CUT.
OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS
THE MANUFACTURER. SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS MEETING THE REQUIREMENTS OF IBC SECTION
RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT,
2303.4 (COMPLETE WITH STRESS DIAGRAMS) TO THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL FOR REVIEW
WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH TWO
SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CONTRACTORS, OR OTHER
PRIOR TO FABRICATION. DESIGN SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF A REGISTERED PROFESSIONAL
16d NAILS, AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16d NAILS. FACE NAIL DOUBLE TOP PLATE
ENTITIES OR PERSONS AT THE PROJECT SITE.
ENGINEER, STATE OF WASHINGTON. PERMANENT AND TEMPORARY BRIDGING SHALL BE INSTALLED IN CONFORMANCE WITH
WITH 16d AT 12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE EIGHT 16d NAILS AT 4" O.C. EACH SIDE OF JOINT.
MANUFACTURER'S SPECIFICATIONS.
6. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR
ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 12"
APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS
21. PREFABRICATED PLYWOOD WEB JOIST DESIGN SHOWN ON PLANS IS BASED ON JOIST MANUFACTURED BY THE WEYERHAEUSER.
O.C. STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS (WITH 7" MINIMUM EMBEDMENT) @ 4'-0"
REQUIREMENT.
ALTERNATE PLYWOOD WEB JOIST MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND
O.C. UNLESS INDICATED OTHERWISE. PROVIDE 3"x3" x1/4" HOT -DIPPED GALVANIZED PLATE WASHERS AT ALL ANCHOR
STRUCTURAL ENGINEER. ALTERNATE JOIST HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN
BOLTS. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH 16d NAILS @ 12" O.C.
7. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY
PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST HANGERS AND OTHER
STAGGERED. REFER TO THE PLANS AND SHEAR WALL SCHEDULE FOR REQUIRED SHEATHING AND NAILING. WHEN NOT
INDICATED, BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED,
HARDWARE SHALL BE COMPATIBLE IN SIZE WITH PLYWOOD WEB JOIST PROVIDED.
OTHERWISE NOTED, PROVIDE GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO ALL STUDS, TOP AND BOTTOM
SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER.
PLATES AND BLOCKING WITH NAILS AT 7" O.C. USE 5d COOLER NAILS FOR 1/2" GWB AND 6d COOLER NAILS FOR 5/8" GWB.
22. PREFABRICATED CONNECTOR PI ATE WOOD ROOF TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE
PROVIDE 15/32" APA RATED SHEATHING (SPAN RATING 24/0) ON EXTERIOR SURFACES NAILED AT ALL PANEL EDGES
8. ALL STRI ICTIJRAI SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY
WITH THE "NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION", ANSI / TP 1-2014 FOR
(BLOCK UNSUPPORTED EDGES), TOP AND BOTTOM PLATES WITH 8d NAILS @ 6" O.C. AND TO ALL INTERMEDIATE STUDS
THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE, AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS
THE SPANS AND CONDITIONS SHOWN ON THE PLANS. LOADING SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE:
AND BLOCKING WITH NAILS @ 12" O.C. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS.
PREPARED BY THE SUPPLIER.
TOP CHORD LIVE LOAD REFER TO DESIGN LOADING CRITERIA
C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE
9. STATEMENT SPEC:IAI INSPECTIONS-
MINIMUM TOP CHORD DEAD LOAD 10 PSF
THAN HALF THE JOIST LENGTH AND AROUND ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE
THE FOLLOWING CONSTRUCTION TYPES ARE TO BE REVIEWED BY A SPECIAL INSPECTOR DESIGNATED BY THE OWNER OR
MINIMUM BOTTOM CHORD DEAD LOAD 5 PSF
SOLID BLOCKING AT ALL BEARING POINTS.
ARCHITECT. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE
SATISFACTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION
WIND UPLIFT (TOP CHORD) VARIES, TO BE CALCULATED BY TRUSS MANUFACTURER
NOTCHES AT THE END OF JOISTS AND RAFTERS SHALL NOT EXCEED 1/4 THE DEPTH OF THE MEMBER. NOTCHES IN THE
REQUIRING SPECIAL INSPECTION. SPECIAL INSPECTION SHALL CONFORM TO SECTION 1704 OF THE 2018 INTERNATIONAL
REFER TO DESIGN LOADING CRITERIA
TOP OR BOTTOM SHALL NOT EXCEED 1/6 THE DEPTH OF THE MEMBER AND SHALL NOT BE LOCATED WITHIN THE MIDDLE
BUILDING CODE. SPECIAL INSPECTION AGENCY SHALL BE RESPONSIBLE FOR KEEPING RECORDS OF SPECIAL INSPECTIONS AND
1/3 OF THE SPAN. THE DIAMETER OF ROUND HOLES BORED IN JOISTS AND RAFTERS SHALL NOT EXCEED 1/3 OF THE
TESTS. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE FURNISHED WITH COPIES OF ALL
WOOD TRUSSES SHALL UTILIZE APPROVED CONNECTOR PLATES (GANG -NAIL OR EQUAL) AND SHALL BE CONFIGURED SUCH THAT
DEPTH OF THE MEMBER AND SHALL NOT BE LOCATED WITHIN 2" FROM THE TOP OR BOTTOM EDGE.
INSPECTION REPORTS AND TEST RESULTS.
THE MAXIMUM OPENING BETWEEN MEMBERS DOES NOT EXCEED 42"X24". SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS
MEETING THE REQUIREMENTS OF INTERNATIONAL BUILDING CODE SECTION 2303.4 TO THE ARCHITECT, STRUCTURAL ENGINEER,
TOENAIL JOISTS TO SUPPORTS WITH TWO 16d NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH
POST INSTALLED ANCHORS: PERIODIC SPECIAL INSPECTION IN ACCORDANCE WITH THE PRODUCTS APPROVED ICC-ES REPORT.
AND BUILDING OFFICIAL FOR REVIEW PRIOR TO FABRICATION. SUBMITTED DOCUMENTS SHALL BEAR THE STAMP AND
SIMPSON METAL JOIST HANGERS IN ACCORDANCE WITH NOTES ABOVE. NAIL ALL MULTI -JOIST BEAMS TOGETHER WITH
SIGNATURE OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHINGTON. PROVIDE FOR SHAPES, BEARING POINTS,
TWO ROWS OF 16d @ 12" O.C. ATTACH RAFTERS AND ROOF TRUSSES AT BEARING LINES WITH H2.5 @ 24" O.C. UNLESS
C;EnTEC'HNI('AI
INTERSECTIONS, HIPS, VALLEYS, ETC. SHOWN ON THE DRAWINGS. EXACT COMPOSITION OF SPECIAL HIP, VALLEY, AND
INTERSECTION AREAS (USE OF GIRDER TRUSSES, JACK TRUSSES, STEP-DOWN TRUSSES, ETC.) SHALL BE DETERMINED BY THE
OTHER METAL CONNECTIONS ARE INDICATED.
10. FOUNDATION NOTES: ALLOWABLE BEARING PRESSURE AND COEFFICIENT OF FRICTION HAVE BEEN ASSUMED PER IBC TABLE
MANUFACTURER UNLESS SPECIFICALLY INDICATED ON THE PLANS. PROVIDE ALL TRUSS -TO -TRUSS AND TRUSS -TO -GIRDER
UNLESS OTHERWISE NOTED ON THE PLANS, APA RATED ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH STRENGTH
1806.2. LATERAL EARTH PRESSURES HAVE BEEN ASSUMED PER IBC TABLE 1610.1. IT HAS BEEN ASSUMED THAT EXISTING SOILS
TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. PROVIDE FOR ALL TEMPORARY AND PERMANENT TRUSS
AXIS PERPENDICULAR TO SUPPORTS AND ATTACHED WITH 10d NAILS @ 6" O.C. TO FRAMED PANEL EDGES AND OVER
ARE A COMBINATION OF SAND, SILTY SAND, AND POORLY GRADED SAND-SILT/SAND GRAVEL MIXES. IF SOILS ARE FOUND TO BE
BRACING AND BRIDGING. THE TRUSS MANUFACTURER SHALL COORDINATE LOCATIONS AND SUPPORT CONFIGURATIONS OF
STUD WALLS AS SHOWN ON PLANS AND @ 12" O.C. TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE
OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN.
PLUMBING, MECHANICAL UNITS, DUCT WORK, AND OTHER MISCELLANEOUS ITEMS WITH THE CONTRACTOR PRIOR TO
CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES
FABRICATION. TRUSSES SHALL BE DESIGNED TO SUPPORT ALL LOADS ASSOCIATED WITH SUCH ITEMS. THE TRUSS SHOP
SHALL HAVE APPROVED TONGUE -AND -GROOVE JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8"
FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED GRADE, UNLESS OTHERWISE
DRAWINGS SHALL INCLUDE ALL DESIGN LOADS AND APPROVED HANGER CONNECTION DETAILS TO TRUSS CHORDS FOR
SPACING AT ALL PANEL EDGES AND ENDS OF ALL ROOF AND FLOOR SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH
NOTED, FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE.
SUPPORT OF HUNG MECHANICAL SYSTEM COMPONENTS. ANY VARIATION FROM THE BEARING POINTS INDICATED ON THE
16d NAILS @ 12" O.C. UNLESS OTHERWISE NOTED. AT BLOCKED FLOOR AND ROOF DIAPHRAGMS PROVIDE FLAT 2X
STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR APPROVAL.
BLOCKING AT ALL UNFRAMED PANEL EDGES AND FASTEN SHEATHING TO FRAMING/BLOCKING AS SPECIFIED.
BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE.
23. OPEN wEB \8100D RI ISRES ARE TO BE TJL SERIES AS MANUFACTURED BY WEYERHAEUSER. TRUSSES SHALL BE DESIGNED BY
ALLOWABLE SOIL PRESSURE 2,000 PSF
THE MANUFACTURER FOR THE SPANS AND CONDITIONS SHOWN ON THE PLANS AND SHALL BE FURNISHED AND INSTALLED IN
LATERAL EARTH PRESSURE (RESTRAINED/UNRESTRAINED) 60 PCF/45 PCF
CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. ALL NECESSARY BRIDGING, BLOCKING, PRE -
LATERAL EARTH PRESSURE (SEISMIC) 8H (ULTIMATE LOAD)
NOTCHED PLATES, ETC. SHALL BE DETAILED AND FURNISHED BY THE MANUFACTURER. SUBMIT SHOP DRAWINGS AND DESIGN
PASSIVE EARTH PRESSURE (INCLUDES FACTOR OF SAFETY = 1.5) 150 PCF
CALCULATIONS MEETING THE REQUIREMENTS OF INTERNATIONAL BUILDING CODE SECTION 2303.4 (COMPLETE WITH STRESS
COEFFICIENT OF FRICTION (INCLUDES FACTOR OF SAFETY = 1.5) 0.25
DIAGRAMS) TO THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL FOR REVIEW PRIOR TO FABRICATION. DESIGN
SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHINGTON.
CONCRETE
PERMANENT AND TEMPORARY BRIDGING SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS.
DESIGN LOADS SHALL MEET OR EXCEED THE FOLLOWING:
11. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH ACI 318-14 AND ACI 301-16. CONCRETE
SHALL ATTAIN A 28-DAY STRENGTH (fc) OF 3500 PSI BASED ON EXPOSURE CLASS F1, SHALL CONTAIN NO LESS THAN 5-1/2 SACKS OF
MINIMUM TOP CHORD LIVE LOAD REFER TO DESIGN LOADING CRITERIA
CEMENT, HAVE A MAXIMUM WATER/CEMENT RATIO OF 0.45, MAXIMUM AGGREGATE OF 3/4-INCH, AND A SLUMP OF 5 INCHES OR LESS.
MINIMUM TOP CHORD DEAD LOAD 10 PSF DEAD LOAD
CONCRETE HAS BEEN DESIGNED BASED ON A CONCRETE STRENGTH (f'c) OF 2500 PSI PER INTERNATIONAL BUILDING CODE SECTION
MINIMUM BOTTOM CHORD DEAD LOAD 5 PSF DEAD LOAD
1705.3 EXCEPTION 2.3 TO AVOID SPECIAL INSPECTIONS AND MATERIAL TESTING.
WIND UPLIFT (TOP CHORD) VARIES, TO BE CALCULATED BY TRUSS MANUFACTURER
ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT
REFER TO DESIGN LOADING CRITERIA
CONFORMING TO ASTM C260, C494M, AND C618. UNLESS OTHERWISE NOTED THE TOTAL AIR CONTENT SHALL BE 5%. AIR
CONTENT SHALL BE SAMPLED IN ACCORDANCE WITH ASTM C172 AND AIR CONTENT MEASURED IN ACCORDANCE WITH ASTM C231
TRUSS SUPPLIERS NOTE: THE TRUSS CONFIGURATIONS, INCLUDING DEPTHS AND MEMBER SIZES SHOWN ON THE DRAWINGS,
OR C173.
INDICATE THE DESIRED TRUSS CONFIGURATION AND ARE TO BE COMPLIED WITH WHEREVER POSSIBLE. IF THE TRUSS
MANUFACTURER IS UNABLE TO MEET THE LOAD REQUIREMENTS SPECIFIED WITH THE TRUSS CONFIGURATION INDICATED THE
12. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENTS S1), GRADE 60, Fy = 60,000 PSI. EXCEPTIONS: ANY
MANUFACTURER IS TO SUBMIT WRITTEN NOTICE TO THAT AFFECT TO THE ARCHITECT PRIOR TO SUBMITTING A COST PROPOSAL
BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, Fy = 40,000 PSI.
OR BID.
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185
IF A DIFFERENT SYSTEM IS PROPOSED THAT REQUIRES REVISIONS TO PRESENT STRUCTURAL FRAMING OR DETAILS, SUCH
SYSTEM SHALL BE CONSIDERED SUBJECT TO THE APPROVAL OF THE OWNER, ARCHITECT, AND STRUCTURAL ENGINEER.
13. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN ACCORDANCE WITH ACI SP-66-04 AND ACI 318-
IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND TRUSS MANUFACTURER TO VERIFY THE WEIGHT AND LOCATIONS
14 CHAPTER 25. LAP ALL REINFORCEMENTS AS FOLLOWS:
OF ALL MECHANICAL EQUIPMENT PRIOR TO SUBMITTING SHOP DRAWINGS. IT SHALL BE NOTED IN THE TRUSS MANUFACTURER'S
BID WHETHER OR NOT AN ALLOWANCE HAS BEEN MADE FOR MECHANICAL UNITS.
BAR SIZE MINIMUM LAP LENGTH MINIMUM HOOK EMBEDMENT
24-INCHES -IN HE
24. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH DOC
4 1-IN HE 8-INCHES
PS 1-09 OR PS 2-18 AND AMERICAN PLYWOOD ASSOCIATION PERFORMANCE STANDARD PRP-108. ORIENTED STRAND BOARD OF
5 -IN HE 11-IN HES
EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. SEE PLANS FOR THICKNESS,
PANEL IDENTIFICATION INDEX AND NAILING REQUIREMENTS. EACH PANEL SHALL BE IDENTIFIED FOR GRADE AND GLUE TYPE BY
PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM
THE TRADEMARKS OF AN APPROVED TESTING AND GRADING AGENCY.
OF 8" AT SIDES AND ENDS.
25. ALL WOOD PI ATFS IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN APPROVED
NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR
PRESERVATIVE, PROVIDE 2 LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER BETWEEN UNTREATED LEDGERS, BLOCKING,
APPROVED BY THE STRUCTURAL ENGINEER. FIELD BENDING OF GRADE 60 REINFORCEMENT SHALL NOT BE ALLOWED.
ETC. AND CONCRETE OR MASONRY.
14. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
PRESSURE TREATED LUMBER SHALL COMPLY WITH THE AMERICAN WOOD PROTECTION ASSOCIATION (AWPA) STANDARD U1,
COMMODITY SPECIFICATION A AS INDICATED BELOW OR HAVE EQUIVALENT ICC-ES APPROVAL.
FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3"
ALL OTHER CASES 1-1/2"
ALL TREATED LUMBER SHALL BEAR THE QUALITY MARK OF AN ACCREDITED INSPECTION AGENCY. THE QUALITY MARK SHALL
INCLUDE:
15. SLABS -ON -GRADE: UNLESS NOTED OTHERWISE SHALL BE 4" CONCRETE, REINFORCED WITH 6X6 W1.4XW1.4 WELDED WIRE FABRIC
CENTERED IN SLAB. UNLESS OTHERWISE DIRECTED BY SOILS REPORT PROVIDE MINIMUM 10 MIL VAPOR BARRIER OVER 4" OF
A. IDENTIFICATION OF TREATING MANUFACTURER
COMPACTED SAND OR GRAVEL.
B. TYPE OF PRESERVATIVE USED
C. MINIMUM PRESERVATIVE RETENTION (PCF)
16. CAST -IN -PI AGE CONCRETE SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF DOOR AND WINDOW
D. END USE FOR WHICH THE PRODUCT IS TREATED
OPENINGS IN ALL CONCRETE WALLS. SEE MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF MISCELLANEOUS MECHANICAL
E. IDENTITY OF THE ACCREDITED INSPECTION AGENCY
OPENINGS THROUGH CONCRETE WALLS. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE
F. STANDARD TO WHICH THE PRODUCT IS TREATED
STRIPS, COLOR, TEXTURE, AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. TOLERANCES FOR ALL
STRUCTURAL CONCRETE AND REINFORCEMENT SHALL BE IN ACCORDANCE WITH ACI 117-10 AND ACI 117.1 R-14.
26. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN
THEIR CATALOG NUMBER C-C-2019. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY
POST INSTAI I ED ANCHORS
HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED
BY MANUFACTURER TO ACHIEVE THE MAXIMUM PUBLISHED ALLOWABLE LOAD. ALL CONNECTORS SHALL BE INSTALLED IN
17. POST-IN_STAI LED ANCHOR SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS,
SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING POST -INSTALLED ANCHORS IN PLACE OF
PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. SHIMS, WHERE REQUIRED, SHALL BE SEASONED AND DRIED AND
MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST -INSTALLED ANCHORS TO AVOID
THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED.
CONFLICTS WITH EXISTING REINFORCEMENT. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE
MANUFACTURER'S WRITTEN INSTRUCTIONS AND ICC-ES REPORT. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE
ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL
SPECIFIED BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER -OF -RECORD ALONG WITH CALCULATIONS THAT
BOLTS AND LAG SCREWS BEARING ON WOOD. ALL LAG SCREWS SHALL BE INSTALLED IN PRE -DRILLED HOLES.
ARE PREPARED & SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF WASHINGTON. THE CALCULATIONS SHALL
DEMONSTRATE THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF
UNLESS NOTED OTHERWISE ALL SAWN LUMBER JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST
HANGERS AND ALL PREFABRICATED PLYWOOD WEB JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "IUS" SERIES JOIST
HANGERS.
Drawings and the
associated cad files
are considered
'instruments of
service' and may not
be used for any
other project or for
any addition to this
project or for
completion of
drawings by others.
All rights reserved.
Z
Q
03LD2023-�7
VJ
M
S
MJa 16
JD
OFE 0 S
DEPMENT IC
PART
M Q
1
(0 W
Z
Z
D
0
ry
W
u7
C)°'
W00
z
0
�
w
Z
Z
Lu
N
ao
p.
z
\0
N
U
w
a
a
O
No
C3
U
m
_
x
w
_J
z
N
rn
">
F--
~
w
DATE PLOTTED
1 /3/2023
SCALE
none
FILE NAME
HILL STRUCTURAL
SHEE
SI
ALLEY -------- 76.13'
----
ALLEY 76.13
--------------
15' rear setback
15' rear
setback
header SW - 1
HDU2
SW - 1
— — existing gardr.
— — —
—
HDU2
—
�
I
— — — — — — — —
_ _
-------- -----
N
I
I
Wood Framing Plan Notes
— — — —
— —
EXISTING ROOF FRAMING
FI
I
— —
I
1. Roof sheathing shall be 15/32" APA Rated sheathing with a
I— —
— — — — I
I
panel index of 24/0. Nail to framing with 8d common nails at
6" oc at panel edges and 12" oc in field unless noted otherwise
— — —
— — — — — —
I
j
on plans. Roof has been designed for 5psf Photovoltaic Panels.
I
I
45
2. Typical floor sheathing shall be 23/32" APA, Sturd-I-Floor
—
— — — — — —
I
15
11
with a panel index of 40/20. Nail to framing with 1Od common
I
EXISTING GARAGE I
nails at 6" oc at panel edges and 12" oc in field unless noted
I_ —
— I — — —
11
SLAB I
otherwise on plans.
—v
I
I
NO CHANGE
3. All headers and beams shall be (2) 2x8 minimum, u.n.o.
Refer to note 4 for support requirements.
'
4. All columns shall be double stud minimum, u.n.o., with the
beam or header bearing fully on the column. Individual studs
—
I
I
shall be nail together per the general structural notes.-
5. All slabs -on -grade shall be 4" reinforced with WWF6x6
— —
—
W l AxW l A u.n.o. Provide minimum 10-milpolypropylene
I———----
�
I
I
vapor barrier under all slabs. Slabs shall rest on a minimum 4
inches of free draining material.
I
— —
—Z HDU2 PER
I
1
DET N on S-3
I
FF]
Eave of addition
I �
SW-x Indicates shearwall per schedule within 5' of existing
`
I_ — - —
— — — — — I — — — — — — —
-
II SSK-G
�
garage roof tobel
hourfire-rated--_
«-� �- ��« ���- r-����I�x�-���«-���«-,rT�
X X ,X„ „x„S/AN-/ X X,\X,\X ,
X X X X X
EXIST
LLJ
L_-------------------------
------
---_
MSTxx Indicates Simpson Holdown
- - X'
— � x— X—\
:X; ;;
HDUxx
X X X XX
/X, /"
X X X X X X
Tv
DC
�
Q
i
JL Indicates Simpson Hanger K\� SW - 1 BLOCKING PER r
u DET N on S-3
O
o X
NE
-----------------------------
�I
oi
kX;�
X� X
FLAT CEILING
N
X�
N r
�]
I
I NEW 4'' SLAB ON GRADE
�N
X'JN
o
`�
washer/dryer
SSK F
X N SW-1
/\X
X�
I r
r
CS 16
\X�
I
N
VAULT CEILING
X�
X
LI 44
� — — — — — 4 x 10 —
_ ...... — — — — — —
N 3-1 2 X 11-7 8 L$ - Attic ventilation
X
�I
HDU2
ti
L r , — — J ,
o 0 4 x 10 u
L �
I -I -
">
vaulted clg=437sf
--- --J
flat clg=771sf
total vented roof area = 1208 sf
cc X
0 % X l
— --
L I —
L — —
O
=
119-008 = 8.05 sf
8.05x144 = 1159.2 s.i. required
oo
X
SS K_A
r 1
4 x 10
1 9-1 2" TJI 1 0
@ 16" O.C.
oo
X
3.5x22 f.p. eave vent @ 41 s.i. each
X
_ _ _
x6
c
N = 615 s.i. supplied @eave `
v
L—. —
in
Q0 I i NEW
o
continuous 20"per ft ridge vent =
tubular 1188s.i.supplied @ridge
_ skylite Total ventilation supplied = 2846 s.i.
\�
a
I
I
r II -
CRAWLSPACE
>
_
J 6x6
SSK-A
00
X
II
area = 728 sf
„
N
\ X
742/150=4.85
in
X
4.85x144=698.4 s.i.
m
\
X
OUTLINE OF
_
of I ventilation req'd
PRE MA UFACTURED ROOF TRUS
EXISTING
O0
01 I 17.5x8.5 vent = 50 s.i.
_STEM _
698.4/50=14 vents
I
Eaveof---------------
9-1/2" TJI 110
@ 16" O.C.
-----�
I 1 9-1/2" TJI 110
@ 16" O.C.
N
addition
�,UEl
X�
within 5' of
A
U J ^' property
HDU2
ISSK-Aline
r II
_
to be 1"hour1
li
°
fire -rated
II
6x6
LI
\X
------
l
1JI
VAULT CEILING
„
SSK-H00
I I
1 1
0
N
FLAT CEILING
X`�
>
jl
I I REVISE AND IMPROVE
O0
of I
-1 1 1
L
X
El
El
EXISTING
1 CRAWLSPACE
'�
X I
I
v
'
o
.�
1
II
I I
=
X'1
X'
13'00
I
11
11
I
L VAULT CEILING
EXISTING DECK
2248 attic
i�
NO CHANGE
°
6x6
access;
o
_
L J
c
V
,
� '�
N \/,
HDU2
II
SSK-E
of I
1
v
>
X
#4 x 2'-0" EPDXY
1 1
1I 1
1
°
X
I PRE -MA UFACTURED ROOF TRUS
DOWEL SPACE TO
❑ ❑ MATCH HORIZ. ❑
1
i�
;�
1O1 1
=
00
\�
-----J
REINF.TO
II
I I
1
(N
X
EXISTING FOUNDATION.
I I
E ISTI G STAIRS T
4" MIN. EMBED
1 1
11 1
FF
-1 _F- _ �
existing hdr
v
_F —1
_F —1 7- —1 7-
X
J
B SE EN
N CHANGE
'
I �
I I
"'
e istin hd e istin hdr X'�
3-12 11-7 LSL
I�------------
-------
---1--- - - - - - - -
------ -
- - - - -
tubular,-,
�kylite J
SSK-C
-�
iubu1 rl
-'�kylit
I\ - 4
AT CEILING
X
=
II
�I_I
ICI
II�
TT TT T
T-7)
JI
�`� J
X�
�
I
I
I
I
I
U0
F \ -I - -I - -I
- I-/
4- �O I� 1 FLAT CEILING
X
NEW
CRAWLSPACE
J
II
z �I
I/z
/
2 x 12 @ 24" O.C.
6X6 W/MIN
area =215sf
1.4x1441 201 6 s.i.
^
,
1 1 1
I \
FLAT CEILII G I 1 I 1 I
X'
�
24" SQUARE FTG
I
I
ventilation req d
17.5x8.5 50
as
or
z �i
or
IzI
-
� ;�
"
00
.—
(/)
-
4--)
---------
vent = s.i.
201.6/50=4 vents
'
N ,.
r
_
Ln
EXISTI BASEMENT
Ln
IwI 1 1 y l
I w I
�I
Q�
N CHANGE
EXISTING
CRAWLSPACE
2 x 6 @ 24 O.C.
X'
y
X
SSK-P
NO CHANGE
N
�'
X'
—
L
9-1/2" TJI 110
@ 16" O.C.
N X
3-1/2 x 9-1/2 LSL FB
HDU4
I I
y � I
1 4 1
X
X,�
r----
I
I
I
I
L
J
SSK-O
,I (2) 2x
SW-3
°
vent
-
„
#4 x 2'-0" EPDXY
II
I I I I I I I X I I I I I
I I I
I I I I I I I
DOWEL SPACE TO
MATCH HORIZ.
I�
REINF. TO
/
\
-------
EXISTING FOUNDATION.
I
I
I
4" MIN. EMBED
\
6X6 W/ MIN
24"SQUARE FTG--------
------
------�
I
L--------------
-------------�
I
o
exi ting h r existing hdr
existin hdr o
EXISTING STOOP
EXISTING
NEW
EXISTING PAVEMENT
NO CHANGE
NO CHANGE
PROPOSED - ROOF FRAMING PLAN 1/4"
= 1'-0"
PROPOSED - FOUNDATION PLAN
1/4" = 1'-0"
Drawings and the
associated cad files
are considered
'instruments of
service' and may not
be used for any
other project or for
any addition to this
project or for
completion of
drawings by others.
All rights reserved.
Z Q
O BLD2023A:�27
VJ
9DB
CO
1 Z23
QJOPEPARM
F MO DS
ME�VICE:
J
CO �
I
(0 W
Z
Z
D
0
0.
W
I..L
Q
U
Z-Itco
W
�
Z
O
w
z
Lu
w
N
p
o�.
Z
'D
W
N
Q
Q
ON
y
O
N
C0
m
=
~
X
Cn
LLJ
J
H
M
Z
3:
t)
~
W
DATE PLOTTED
4/25/2023
SCALE
VARIES
FILE NAME
HILL FINAL DEMO ADD
SHEET
S2