Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED-BLD2023-0510+Manufacturer_Specifications_and_Installation_Instructions+4.25.2023_7.33.30_AM+3502793
L i ' I I o� Heating & Cooling Systems PREFERRED'" SERIES ALUMINUM EVAPORATOR COILS WITH PURON° REFRIGERANT ENHANCED COMFORT AND ENERGY SAVINGS, PLUS EXCEPTIONAL SERVICE FROM YOUR BRYANT DEALER Top Reasons It Takes Bryant PASSIONATE SERVICE Bryant dealers do more than just deliver quality products like our Preferred'" Series aluminum evaporator coils. They also deliver knowledge, experience and Whatever It Takes° to get each job done right, the first time. You and your system will receive the attention to detail and professional service delivered only by Bryant dealers. Customized Comfort EXCEEDING EXPECTATIONS With more than 100 years of experience, Bryant offers a full lineup of products designed with whole -home comfort in mind. Through innovative design and rigorous testing, our products are built to exceed expectations, backed by Bryant warranty protection. CUSTOMIZED COMFORT SOLUTIONS Heating and cooling solutions are not one size fits all. Our dealers provide solutions based on your specific needs. From financing and rebates to reliable products professionally installed, Bryant provides options that help keep you and your wallet comfortable. NEW CONVENIENCES With a diverse line of products to address almost any need, including programmable thermostats with Wi-Fi° capabilities, convenient comfort can be yours when you choose Bryant. EFFICIENCY & SAVINGS High -efficiency comfort systems can reduce your energy consumption and carbon footprint. By reducing monthly utility bills over the life of your system, you'll see how efficient equipment pays off. Bryant offers a variety of aluminum evaporator coils to match your Bryant comfort system. Your Bryant dealer can help you decide which is right for you. All designed for use with Puron° refrigerant. A -Coils: Best airflow and highest AHRI ratings Model CAPMP Multi -Poise Cased A -Coil Model CAPVP Vertical Cased A -Coil N-Coils: Compact size for tight applications Model CNPHP Horizontal Cased N-Coil Model CAPVU Vertical Uncased A -Coil Model CNPVP/T Model CNPVU Vertical Cased N-Coil Vertical Uncased N-Coil Transition Width Slab Coils: Horizontal -specific applications Model CSPHP Horizontal Cased Slab Coil Warranty To the original owner, Bryant Preferred'" Series aluminum evaporator coils are covered by a 10-year parts limited warranty upon timely registration of your new equipment! Ask your Bryant dealer about optional extended warranties, which may include labor. Home Comfort Components Many people don't realize that an evaporator coil is a key component to an air conditioner or heat pump system. Typically mounted to a furnace or fan coil inside your home, it's the main point of contact where heat transfer takes place so cool air can be distributed to your living areas. —sp= �o Model CAPVU Vertical Uncased A -Coil i � 0— ;±k{�}� Model CNPVP Vertical Cased N-Coil &DURATECH'" 0. ENVIRONMENTALLY SOUND, ENERGY -EFFICIENT Bryant PreferredT" Series aluminum evaporator coils are designed for use with Puron® refrigerant to provide years of environmentally sound, trouble -free performance. 0 ENHANCED COMFORT Our Thermostatic Expansion Valve (TXV) ensures proper refrigerant flow during fluctuating pressures and conditions for top reliability and energy -efficient operation. 9 DURABILITYAND DRAINAGE Our base pan is made of a corrosion -resistant composite material. Integrated sloped drainage helps reduce build-up of mold, bacteria and other airborne pollutants. LASTING LOOKS AND PERFORMANCE The sturdy cabinet on our cased models is painted to match your Bryant furnace to provide years of scratch - resistant good looks. (Models CAPVP, CAPMP, CNPVP, CNPHP, CSPHP) LONGER LIFE Bryant advancements in aluminum manufacturing technology result in higher product reliability and as a result, potentially longer system life. f , �f :k f Y 1 rris�� Wi-Fill is a registered trademark of Wi-Fi Alliance Corporation. For more than a century, homeowners have associated Bryant heating and cooling products with the highest standards of indoor comfort and Bryant dealers as service leaders. Through commitment and dedication of our product development and manufacturing teams, we have consistently met every new challenge head-on and delivered the products to meet or exceed expectations. Our national network of passionate Bryant dealers is at the forefront of our success. Knowledgeable in the field, and equipped to address your home comfort needs, our dealers deliver customized comfort solutions to you and your family by doing... WHATEVER IT TAKES: Since 1904 [1 i DURACOA dealer Imprint Manufacturer reserves the right to discontinue or change at anytime, specifications or designs without notice or without incurring obligations. Third party logos and trademarks are property of their respective owners. 915SB LegacyTM 95 Single -Stage, 4-Way Multipoise, Condensing Gas Furnace Product Data A11264 The 915SB Multipoise Condensing Gas Furnace features the single -stage Legacy TM System. The fixed -speeds, constant torque (FCT) ECM blower motor is at the heart of the electrical efficiency provided by this furnace. With an Annual Fuel Utilization Efficiency (AFUE) of 96.2% AFUE, this furnace provides added savings over standard gas furnaces. This Legacy Gas Furnace features 4-way multipoise installation flexibility, and is available in model eleven sizes. All sizes except the 26,000 BTUH model can be vented for direct vent/two-pipe, ventilated combustion air, or single -pipe applications. The 26,000 BTUH model can use the same 2-pipe venting system using outside air for combustion, but is not considered direct -vent. A Bryant Legacy Control and Legacy Air Conditioner or Heat Pump, can be used to form a complete Legacy Line System. All sizes are design certified in Canada. Specific sizes are design certified for use in Manufactured Housing (Mobile Home) applications when used with factory -approved MH accessory kit. LEA M PERFORMANCE 1[hrya0 7 nt • Fixed -speeds, constant torque (FCT) ECM blower motor for electrically efficient operation all year long in heating, cooling and continuous fan operation. • Single -speed inducer motor, and single -stage gas valve. • Silicon Nitride PerfectLightTM Hot Surface Igniter. • Perfect Humidity® technology removes more moisture than a standard furnace during cooling operation (when installed with a matched air conditioner or heat pump) • Adjustable blower speed for heating and cooling. • Aluminized -steel primary heat exchanger. • Stainless -steel condensing secondary heat exchanger. INSTALLATION FLEXIBILITY • 4-way multipoise design for upflow, downflow or horizontal installation, with unique vent elbow for optional venting through -the -cabinet downflow venting capability. • Factory -configured ready for upflow applications. • Ideal height 35" (889 mm) cabinet: short enough for taller coils, but still allows enough room for service. • Two -pipe venting, single -pipe venting or ventilated combustion air. APPLICATIONS Approved for Twinning applications with accessory kit (42060E17, 048080E17, 060080E21, 60100E21, 66120E24, 6614OE24 models, only). Approved for Manufactured Housing/Mobile Home applications with MH accessory kit. Convertible to propane with gas conversion accessory kit. CERTIFICATIONS • All sizes meet ENERGY STAR® Verizon 4.1 criteria for gas furnaces: 95%+ AFUE. • Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193. • All sizes can be installed in air quality management districts with a 40 ng/J NOx emissions requirments. 1 0 Use of the AHRI Certified Z Mark indicates a manufacturer's participation in the program. For FA verification of certification for individual products, Sp gpat go to www.ahridirectory.org. scatty A200350 915SB: Product Data FURNACE CASING DIMENSIONS (IN.) RATED HEATING OUTPUT* BTUH AFUE ENERGY STAR® HEATING AIRFLOW COOLING CFM @ 0.5 ESP (in. W.C.) MOTOR HP H D W UPFLOW/ HORIZONTAL DOWNFLOW HEATING CFMt HEATING ESP (in. W.C.) 915SB30026E14 35 29.50 14.20 25,000 96.0% 95.0% YES 605 0.10 895 1/3 915SB3004OE14 35 29.50 14.20 39,000 96.0% 95.0% YES 695 0.10 950 1 /2 915SB3604OE17 35 29.50 17.50 39,000 96.2% 95.0% YES 650 0.10 1010 1 /2 915SB36060E14 35 29.50 14.20 58,000 95.0% 95.0% YES 930 0.12 1120 1/2 915SB42060E17 35 29.50 17.50 58,000 96.2% 95.0% YES 1010 0.12 1330 3/4 915SB4808OE17 35 29.50 17.50 78,000 96.2% 95.0% YES 1325 0.12 1665 3/4 915SB6008OE21 35 29.50 21.00 78,000 96.2% 95.0% YES 1330 0.12 1855 1 915SB60100E21 35 29.50 21.00 97,000 96.2% 95.0% YES 1730 0.15 2125 1 915SB66100E21 35 29.50 21.00 97,000 96.2% 1 95.0% YES 1785 0.15 2065 1 915SB6612OE24 35 29.50 24.00 116,000 96.1% 95.0% YES 2020 0.20 2105 1 915SB6614OE24 35 29.50 24.00 135,000 95.0% 95.0% YES 2130 0.20 2310 1 *. Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate. 1. Heating CFM at factory default blower motor heating tap settings ESP - External Static Pressure FEATURES AND BENEFITS HYBRID HEAT® Dual Fuel System - This system can provide more control over your monthly energy bills by automatically selecting the most economical method of heating. With HYBRID HEAT components, our system automatically switches between the gas furnace and the electric heat pump as outside temperatures change to maintain greater efficiency and comfort than with any traditional single -source heating system. The heat pump also delivers high -efficiency cooling in the summer. Perfect LightTm Igniter - Bryant's unique SiN igniter is not only physically robust but it is also electrically robust. It is capable of running at line voltage and does not require complex voltage regulators as do other brands. This unique feature further enhances the gas furnace reliability and continues Bryant's tradition of technology leadership and innovation in providing a reliable and durable product. LegacyTm ECM Blower Motor - This basic ECM, or electronically commutated motor, can provide an efficiency enhancement for select Bryant air conditioner or heat pump systems. It uses less electrical power than its PSC counterpart and has 5 speeds. Reliable Heat Exchanger Design - The aluminized steel, clam shell primary heat exchanger has a crimped, no -weld seam create an efficient, robust design for this essential component. The condensing heat exchanger, a stainless steel fin and tube design, is positioned in the furnace to extract additional heat. Stainless steel coupling box componentry between heat exchangers has exceptional corrosion resistance in both natural gas and propane applications. Media Filter Cabinet - Enhanced indoor air quality in the home is made easier with our media filter cabinet -accessory (purchased separately). When installed as a part of the system, this cabinet allows for easy and convenient addition of a Bryant high efficiency air filter. 4-Way Multipoise Design - One model for all applications - there is no need to stock special downflow or horizontal models when one unit will do it all. Direct or Single -pipe Venting, or Optional Ventilated Combustion Air - All sizes except the 26,000 BTUH model can be vented for direct vent/two-pipe, ventilated combustion air, or single -pipe applications. The 26,000 BTUH model can use the same 2-pipe venting system using outside air for combustion, but is not considered direct -vent. Sealed Combustion System - This furnace brings in combustion air from outside the furnace, which results in especially quiet operation. By sealing the entire combustion vestibule, the entire furnace can be made quieter, not just the burners. Insulated Casing - Foil -faced insulation in the heat exchanger section of the casing minimizes heat loss. Monoport Burners - The burners are specially designed and finely tuned for smooth, quiet combustion and economical operation. Bottom Closure - Factory -installed for side return; easily removable for bottom return. The multi -use bottom closure can also serve for roll -out protection in horizontal applications, and act as the bottom closure for the optional return air base accessory. Blower Access Panel Switch - Automatically shuts off 115-v power to furnace whenever blower access panel is opened. Quality Registration - Our furnaces are engineered and manufactured under a quality management system registered to ISO 9001. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 915SB: Product Data MODEL NUMBER NOMENCLATURE 1 2 3 Heat Exchanger Tier/NOx AFUE/NOx 9 8 7 I I I a=so% 0=80% 0 = Base 1 = 80 % Low Nox 1 = Legacy Line ---- 2 = Preferred 2 = 92 3 = Ultra Low Nox 5 = 95% 8 = Evolution 6 = 96% 7=97% 8=98% FURNACE COMPONENTS 4 5 6,7 Major Cooling Heating Stages Series Capacity (CFM) M B 42 1 1 1 M = Modulating S = Single Stage T = Two -Stage FLAME SENSOR MANUAL RESET ROLLOUT SWITCH GAS VALVE - OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE). ELECTRICAL JUNCTION BOX (IF REQUIRED, — LOCATION MAY VARY) BLOWER DOOR —_ SAFETY SWITCH FURNACE CONTROL BOARD RATING PLATE NOT SHOWN (LOCATED ON BLOWER DOOR) A B C D = 800 CFM = 1000 CFM = 1200 CFM = 1400 CFM = 1600 CFM = 2000 CFM 8 - 10 11 12 - 13 14 15 16 Voltage Minor Heating Input Motor Type Width (1-phase) Un-used Series 060 C 17 A A I I C = Comm. Variable - I I I I Speed Constant Airflow F_23ov/5oHzzEE (VCA) ECM 14 = 142 E= Fixed -Speeds Constant Torque 17 = 17.5 21 = 21.0 026 = 26,000 BTUh (FCT) ECM V = Variable -Speed 24 = 24.5 040 = 40,000 BTUh Constant Torque 060 = 60,000 BTUh (VCT) ECM 155 = 155,000 BTUh HOT SURFACE IGNITER MANUAL RESET ROLLOUT SWITCH MAIN LIMIT SWITCH (BEHIND GAS VALVE) INDUCER MOTOR ASSEMBLY BLOWER AND MOTOR A200522 A190145 For California Residents: If installed with a manufactured (mobile) home conversion kit in SCAQMD: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFumaceRebate.com Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 915SB: Product Data SPECIFICATIONS The furnace should be sized to provide 100 percent of the design heating load requirement plus any margin that occurs because of furnace model size capacity increments. None of the furnace model sizes can be used if the heating load is 12,000 BTUH or lower. Use Air Conditioning Contractors of America (Manual J and S); American Society of Heating, Refrigerating, and Air -Conditioning Engineers; or other approved engineering method to calculate heating load estimates and select the furnace. Excessive oversizing of the furnace may cause the furnace and/or vent to fail prematurely, customer discomfort and/or vent freezing. Failure to follow these guidelines is considered faulty installation and/or misapplication of the furnace; and resulting failure, damage, or repairs may impact warranty coverage. Furnace Model 30026E14 3004OE14 3604OE17 3606OE14 4206OE17 Heating Capacity and Efficiency Input (BTUh) 26,000 40,000 40,000 60,000 60,000 Output (BTUh) 25,000 39,000 39,000 58,000 58,000 Certified Temperature Rise Range OF (°C) 25 - 55 (14 - 31) 40 - 70 (22 - 39) 40 - 70 (22 - 39) 45 - 75 (25 - 42) 40 - 70 (22 - 39) Airflow Capacity and Blower Data Rated External Static Heating Pressure (in. w.c.) Cooling 0.10 0.10 0.10 0.12 0.12 0.50 0.50 0.50 0.50 0.50 Airflow Delivery @ Rated Heating ESP (CFM) Cooling 605 695 650 930 1010 895 950 1010 1120 1330 Cooling Capacity (tons) @ 400 CFM/ton CFM/ton 350 CFM/ton 2 2 2.5 2.5 3.5 2.50 2.50 3 3 4 Direct -Drive Motor Type Electronically Commutated Motor (ECM) Direct -Drive Motor HP 1/3 1/2 1/2 1/2 3/4 Motor Full Load Amps 4.4 6.3 6.8 6.3 8.8 RPM Range 400 - 1200 600 - 2000 400 - 1200 600 - 2000 400 - 1200 Speed Selections 5 5 5 5 5 Blower Wheel Dia x Width in. 11 x 7 11 x 7 11 x 8 11 x 7 11 x 8 Air Filtration System Field Supplied Filter Filter Used for Certified Watt Data 325531-40` Electrical Data Input Voltage Volts -Hertz- Phase 115-60-1 Operating Voltage Range Min -Max 104-127 Maximum Input Amps Amps 5.1 7.0 7.5 7.1 9.6 Unit Ampacity Amps 7.3 9.7 10.3 9.8 12.9 Minimum Wire Size AWG 14 14 14 14 14 Maximum Wire Length@ Feet Minimum Wire Size (M) 50 38 36 38 28 (15.5) (11.7) (10.9) (11.5) (8.7) Maximum Fuse/Ckt Bkr (Time -Delay Type Recommended) Amps 15 15 15 15 15 Transfomer Capacity (24vac output) 40 VA External Control Power Heating Available Cooling 27.9 VA 34.6 VA Controls Gas Connection Size 1/2" - NPT Burners (Monoport) 2 2 2 3 3 Gas Valve (Redundant) Manufacturer White Rodgers Minimum Inlet Gas pressure (in. we) 4.50 Maximum Inlet Gas pressure (in. we) 13.60 Manufactured (Mobile) Home Kit See Accessory Listing Ignition Device Silicon Nitride Heating Blower Control (Heating Off -Delay) Adjustable: 90, 120, 150, 180 seconds Cooling Blower Control (Time Delay Relay) 90 seconds Communication System none Thermostat Connections Com 24V, R, W, G, Y Accessory Connections EAC (115vac); HUM (24vac); 1-stg AC (via Y) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 915SB: Product Data Furnace Model 48080E17 60080E21 60100E21 66100E21 66120E24 66140E24 Heating Capacity and Efficiency Input (BTUh) 80,000 80,000 100,000 100,000 120,000 140,000 Output (BTUh) 78,000 78,000 97,000 97,000 117,000 135,000 Certified Temperature Rise Range OF (°C) 40 - 70 (22 - 39) 40 - 70 (22 - 39) 40 - 70 (22 - 39) 40 - 70 (22 - 39) 40 - 70 (22 - 39) 45 - 75 (25 - 42) Airflow Capacity and Blower Data Rated External Heating 0.12 0.12 0.15 0.15 0.20 0.20 Static Pressure (in. Cooling w.c.) 0.50 0.50 0.50 0.50 0.50 0.50 Airflow Delivery @ Heating 1325 1330 1730 1785 2020 2130 Rated ESP (CFM) Cooling 1665 1855 2125 2065 2105 2310 Cooling Capacity 400 CFM/ton 4 5 5 5 5 5 (tons) @ CFM/ton 350 CFM/ton 4.50 5.50 6 5.5 6 6 Direct -Drive Motor Type Electronically Commutated Motor (ECM) Direct -Drive Motor HP 3/4 1 1 1 1 1 Motor Full Load Amps 9.2 11.5 11.7 11.0 11.0 11.7 RPM Range 400-1200 400-1200 400-1200 400-1300 400-1300 400-1200 Speed Selections 5 5 5 5 5 5 Blower Wheel Dia x Width in. 11 x 8 11 x 10 11 x 10 11 x 10 11 x 11 11 x 11 Air Filtration System Field Supplied Filter Filter Used for Certified Watt Data 325531-40* Electrical Data Input Voltage Volts -Hertz- Phase 115-60-1 Operating Voltage Range Min -Max 104-127 Maximum Input Amps Amps 10 12.3 12.6 12.6 12.4 12.6 Unit Ampacity Amps 13.4 16.3 16.7 16.7 16.7 16.7 Minimum Wire Size AWG 14 12 12 12 12 12 Maximum Wire Feet 27 35 34 34 35 34 Length@ Minimum Wire Size (M) (8.4) (10.7) (10.5) (10.5) (10.7) (10.5) Maximum Fuse/Ckt Bkr (Time -Delay Type Recommended) Amps 15 20 20 20 20 20 Transfomer Capacity (24vac output) 40 VA External Control Heating 27.9 VA Power Available Cooling 34.6 VA Controls Gas Connection Size 1/2" - NPT Burners (Monoport) 4 4 5 1 5 6 7 Gas Valve (Redundant) Manufacturer White Rodgers Minimum Inlet Gas pressure (in. wc) 4.50 Maximum Inlet Gas pressure (in. wc) 13.60 Manufactured (Mobile) Home Kit See Accessory Listing Ignition Device Silicon Nitride Heating Blower Control (Heating Off -Delay) Adjustable: 90, 120, 150, 180 seconds Cooling Blower Control (Time Delay Relay) 90 seconds Communication System none Thermostat Connections Com 24V, R, W, G, Y Accessory Connections EAC (115vac); HUM (24vac); 1-stg AC (via Y) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 915SB: Product Data ACCESSORIES DESCRIPTION PART NUMBER 30026E14 3004OE14 3604OE17 3606OE14 4206OE17 Vent Kit - Through the Cabinet KGADC0101 BVC X X X X X Vent Terminal -Concentric - 2" (51 mm) KGAVT0701 CVT See Venting Tables Vent Terminal - Concentric - 3" (76 mm) KGAVTO801 CVT Vent Terminal Bracket - 2" (51 mm) KGAVTO101 BRA Vent Terminal Bracket - 3" (76 mm) KGAVT0201 BRA Vent Kit - Rubber Coupling KGAAC0101 RVC Freeze Protect Kit - Condensate Drain Line Tape KGAHT0101CFP X X X X X Freeze Protect Kit - Condensate Trap with Heat Pad KGAHT0201 CFP X X X X X CPVC to PVC Drain Adapters - 1/2" CPVC to 3/4" PVC KGAAD0110PVC X X X X X Horizontal Trap Grommet - Direct Vent KGACK0101 HCK All 2-Pipe Horizontal Condensate Neutralizer Kit P908-0001' X X X X X External Trap Kit KGAET0201 ETK X X X X X Downflow Furnace Base Kit for Combustible Floors KGASB0201 ALL X X X X X Coil Adapter Kits - No Offset KGADA0101ALL X X X X X Coil Adapter Kits - Single Offset KGADA0201ALL X X X X X Coil Adapter Kits - Double Offset KGADA0301ALL X X X X X Return Air Base (Upflow Applications) 14.0-in. wide KGARP0301 B14 X X X Return Air Base (Upflow Applications) 17.5-in. wide KGARP0301 B17 X X IAQ Device Duct Adapters 20.0-in. IAQ to 16 in. Side Return KGAAD0101 MEC 20"x25 IAQ Devices IAQ Device Duct Adapters 24.0-in. IAQ to 16 in. Side Return KGAAD0201 MEC 24"x25' IAQ Devices Mobile Home Kit KGCMH0601KIT X X X X Gas Conversion Kit - Nat to LP AGAGC9NPL01A X - Gas Conversion Kit - LP to Nat AGAGC9PNL01A X - Gas Conversion Kit - Nat to LP AGAGC9NPS01 B X X X X Gas Conversion Kit - LP to Nat AGAGC9PNS01 B X X X X Gas Valve Tower Port Adapter Kit 92-1003* X X X X X Twinning Kit AGATWNDTE01A X Blower Speed Tap Jumper Kit (10 piece) AGABLRJMP10A X X X X X External Bottom ReturnFilter Rack - 14.5 x 25 inches (366 x 635 mm) FHG1425-2 X X - X External Bottom ReturnFilter Rack - 16 x 25 inches (406 x 635 mm) FHG1625 2 X X Filter Washable - 16x25x3/4 (406x635x19 mm) 1 325531-402* X X X I X X *. Purchased from RCD Components X = Used with the model furnace Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 915SB: Product Data ACCESSORIES (continued) DESCRIPTION PART NUMBER 4808OE17 6008OE21 60100E21 66100E21 6612OE24 6614OE24 Vent Kit - Through the Cabinet KGADC0101 BVC X X X X X X Vent Terminal - Concentric - 2" (51 mm) KGAVT0701CVT See Venting Tables Vent Terminal - Concentric - 3" (76 mm) KGAVT0801CVT Vent Terminal Bracket - 2" (51 mm) KGAVTO101 BRA Vent Terminal Bracket - 3" (76 mm) KGAVT0201 BRA Vent Kit - Rubber Coupling KGAAC0101 RVC Freeze Protect Kit - Condensate Drain Line KGAHT0101 CFP X X X X X X Tape Freeze Protect Kit - Condensate Trap with Heat KGAHT0201 CFP X X X X X X Pad CPVC to PVC Drain Adapters - 1/2" CPVC to KGAAD0110PVC X X X X X X 3/4" PVC Horizontal Trap Grommet - Direct Vent KGACK0101 HCK All 2-Pipe Horizontal Condensate Neutralizer Kit P908-0001. X X X X X X External Trap Kit KGAET0201 ETK X X X X X X Downflow Furnace Base Kit for Combustible KGASB0201ALL X X X X X X Floors Coil Adapter Kits - No Offset KGADA0101ALL X X X X X X Coil Adapter Kits - Single Offset KGADA0201ALL X X X X X X Coil Adapter Kits - Double Offset KGADA0301ALL X X X X X X Return Air Base (Upflow Applications) 17.5-in. KGARP0301 B17 X - wide Return Air Base (Upflow Applications) 21.0-in. KGARP0301 B21 X X X wide Return Air Base (Upflow Applications) 24.5-in. KGARP0301 B24 X X wide IAQ Device Duct Adapters 20.0-in. IAQ to 16 in. KGAAD0101 MEC 20"x25" IAQ Devices Side Return IAQ Device Duct Adapters 24.0-in. IAQ to 16 in. KGAAD0201 MEC 24"x25" IAQ Devices Side Return Mobile Home Kit KGCMH0601 KIT X X X X X - Gas Conversion Kit - Nat to LP AGAGC9NPS01 B X X X X X X Gas Conversion Kit - LP to Nat AGAGC9PNS01 B X X X X X X Gas Valve Tower Port Adapter Kit 92-1003' X X X X X X Twinning Kit AGATWANDTE01 X X X X X Blower Speed Tap Jumper Kit (10 piece) AGABLRJMP10A X X X X X X External Bottom Return Filter Rack - 16 x 25 X inches (406 x 635 mm) FHG1625 2' External Bottom Return Filter Rack - 20x 25 X X X inches (508 x 635 mm) FHG2025-2 External Bottom Return Filter Rack - 24.5 x 24 X X inches (607 x 607 mm) FHG2424-2 Filter Washable - 16x25x3/4 (406x635x19 mm) 325531-402* X Filter Washable - 20x25x3/4 (508x635x19 mm) 325531-403* X X X Filter Washable - 24x25x3/4 (610x635x19 mm) 325531-404* X X *. Order from RCD Components X = Used with the model furnace Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 915SB: Product Data ACCESSORIES (continued) DESCRIPTION Gas Orifice Kit - #42 (Nat Gas) LH32DB207 See Installation Instructions for model, altitude, and heat value usages. Gas Orifice Kit - #43 (Nat Gas) LH32DB202 Gas Orifice Kit - #44 (Nat Gas) LH32DB200 Gas Orifice Kit - #45 (Nat Gas) LH32DB205 Gas Orifice Kit - #46 (Nat Gas) LH32DB208 Gas Orifice Kit - #47 (Nat Gas) LH32DBO78 Gas Orifice Kit - #48 (Nat Gas) LH32DBO76 Gas Orifice Kit - #54 (LP) LH321DB203 Gas Orifice Kit - #55 (LP) LH32DB201 Gas Orifice Kit - #56 (LP) LH32DB206 Gas Orifice Kit 1.25mm (LP) LH32DB209 Gas Orifice Kit - 1.30mm (LP) LH32DB210 DESCRIPTION ACCESSORY HUMIDIFIER Model HUM HEAT RECOVERY VENTILATOR Model HRV ENERGY RECOVERY VENTILATOR Model ERV UV LIGHTS Model UVL Bryant has a wide variety of thermostats for your system, please visit www.Bryant.com to see all thermostat and IAQ products. DESCRIPTION ACCESSORY 14" 17" 21" 24" Bryant Carbon Monoxide Alarm (10 pack) COALMBBNRB02-A10 X X X X Bryant Evolution Air Purifier - 16x25 (407x635 mm) DGAPAXX1625 X X Bryant Evolution Air Purifier - 20x25 (508x635 mm) DGAPAXX2025 X X Bryant Evolution Air Purifier Repl. Filter- 16x25 (407x635 mm) PGAPXCAR1625A02 X X Bryant Evolution Air Purifier Repl. Filter- 20x25 (508x635 mm) PGAPXCAR2025A02 X X Cartridge Media Filter - 16" (407 mm) (MERV 11) FILXXCAR0116 X X - Cartridge Media Filter - 16" (407 mm) (MERV 8) FILXXCAR0016 X X - Cartridge Media Filter - 20" (508 mm) (MERV 8) FILXXCAR0020 X Cartridge Media Filter - 20" (508 mm) (MERV11) FILXXCAR0120 X Cartridge Media Filter - 24" (610 mm) (MERV 8) FILXXCAR0024 - X Cartridge Media Filter - 24" (610 mm) (MERV11) FILXXCAR0124 - X EZ Flex Cabinet Side or Bottom - 16" EZXCAB--0016 X X EZ Flex Cabinet Side or Bottom - 20" EZXCAB--0020 X X EZ Flex Replacement Filters 16" MERV 10 EXPXXFIL0016 X X EZ Flex Replacement Filters 16" MERV 13 EXPXXFIL0316 X X EZ Flex Replacement Filters 20" MERV 10 EXPXXFIL0020 X EZ Flex Replacement Filters 20" MERV 13 EXPXXFIL0320 X EZ Flex Replacement Filters 24" MERV 10 EXPXXFIL0024 X EZ Flex Replacement Filters 24" MERV 13 EXPXXFIL0324 X EZ-Flex Filter with End Caps - 16" (407 mm) (MERV 10) EXPXXUNVO016 X X EZ-Flex Filter with End Caps - 16" (407 mm) (MERV 13) EXPXXUNV0316 X X EZ-Flex Filter with End Caps - 20" (508 mm) (MERV 10) EXPXXUNVO020 X EZ-Flex Filter with End Caps - 20" (508 mm) (MERV 13) EXPXXUNV0320 X EZ-Flex Filter with End Caps - 24" (610 mm) (MERV 10) EXPXXUNVO024 X EZ-Flex Filter with End Caps - 24" (610 mm) (MERV 13) EXPXXUNV0324 X Media Filter Cabinet - 20" FILCABXL0020 X Media Filter Cabinet - 24" FILCABXL0024 X Media Filter Cabinet -16" FILCABXL0016 X X - Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 915SB: Product Data Air Delivery - CFM (Bottom Return With Filter) UNIT SIZE WIRE LEAD COLOR SPEED TAPS 2 3 (Function) EXTERNAL STATIC PRESSURE (IN.W.C.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Black Cooling. Do not use for heating 1045 1010 975 935 895 855 810 760 715 670 Yellow Alt Cooling or alt Heating 820 770 730 680 630 585 530 480 435 385 30026E14 Orange Alt Cooling or alt Heating 655 600 550 495 435 385 335 265 - - Blue 7 Heating or alt Cooling 605 545 490 435 375 335 255 - Red 7 Alt Cooling. Do not use for heating 480 415 360 305 235 - - - Gray Cooling. Do not use for heating 1050 1025 1000 975 950 920 895 870 845 820 Yellow Alt Cooling. Do not use for heating 920 890 860 830 805 775 745 715 690 660 3004OE14 Orange Alt Cooling or alt Heating 735 700 665 630 595 555 525 490 450 415 Blue Heating or alt Cooling 695 660 625 590 555 515 480 445 405 370 Red 7 Alt Cooling. Do not use for heating 540 495 455 410 365 320 280 235 - - Gray Cooling. Do not use for heating 1180 1140 1100 1055 1010 960 915 860 805 735 Yellow Alt Cooling. Do not use for heating 880 845 810 780 745 710 675 640 600 570 3604OE17 Blue Heating or alt Cooling 650 610 560 515 470 435 395 360 325 265 Orange 7 Alt Cooling. Do not use for heating 525 460 405 350 320 275 210 - - - Red 7 Alt Cooling. Do not use for heating 515 420 350 310 270 205 - - - - Gray Cooling. Do not use for heating 1225 1200 1175 1145 1120 1095 1065 1040 1015 990 Yellow Alt Cooling. Do not use for heating 1105 1080 1050 1020 990 965 935 905 880 850 3606OE14 Blue Heating or alt Cooling 940 910 875 845 810 775 745 710 680 645 Orange Alt Cooling or alt Heating 725 690 650 610 570 530 490 445 405 365 Red 7 Alt Cooling. Do not use for heating 545 495 445 395 345 295 245 - - - Gray Cooling. Do not use for heating 1475 1445 1405 1370 1330 1290 1255 1215 1175 1140 Yellow Alt Cooling or alt Heating 1230 1190 1155 1120 1085 1050 1005 970 925 885 4206OE17 Orange Alt Cooling or alt Heating 1070 1030 990 950 920 875 840 800 755 715 Blue Heating or alt Cooling 1020 975 940 900 860 820 775 740 690 650 Red Alt Cooling. Do not use for heating 700 590 535 485 460 390 340 300 275 210 Gray 5,6 Cooling. Do not use for heating 1820 1790 1755 1710 1665 1620 1570 1525 1480 1435 Yellow Alt Cooling or all Heating 1455 1420 1380 1345 1310 1275 1240 1205 1170 1135 4808OE17 Blue Heating or alt Cooling 1335 1295 1260 1220 1185 1150 1110 1075 1040 1005 Orange Alt Cooling or alt Heating 1110 1065 1020 980 935 895 850 810 770 725 Red 7 Alt Cooling. Do not use for heating 425 335 240 - - - - - - - Gray 5, 6 Cooling. Do not use for heating 2045 1995 1950 1900 1855 1805 1760 1710 1660 1615 Yellow Alt Cooling. Do not use for heating 1665 1625 1575 1530 1480 1435 1385 1340 1285 1240 6008OE21 Orange Alt Cooling or alt Heating 1475 1420 1370 1320 1270 1220 1170 1125 1070 1025 Blue Heating or all Cooling 1345 1290 1235 1180 1130 1080 1025 975 935 885 Red Alt Cooling. Do not use for heating 1155 1080 1015 960 895 845 790 735 675 620 Gray 5,6 Cooling. Do not use for heating 2280 2240 2200 2165 2125 2085 2020 1910 1795 1665 Yellow 5,6 Alt Cooling. Do not use for heating 1860 1815 1775 1730 1690 1645 1605 1560 1515 1465 60100E21 Blue Heating or alt Cooling 1755 1710 1665 1620 1580 1535 1485 1440 1390 1340 Orange Alt Cooling or alt Heating 1530 1480 1425 1380 1325 1275 1215 1160 1110 1060 Red Cooling. Do not use for heating 1340 1285 1230 1170 1110 1050 990 930 875 820 Gray 5,6 Cooling. Do not use for heating 2215 2180 2145 2105 2065 2025 1985 1940 1900 1860 Yellow 5, 6 Alt Cooling. Do not use for heating 2115 2080 2035 2000 1960 1920 1880 1835 1790 1740 66100E21 Orange 5,6 Alt Cooling. Do not use for heating 1975 1935 1890 1850 1805 1760 1720 1670 1620 1570 Blue 5,6 Heating or alt Cooling 1810 1765 1715 1670 1620 1570 1515 1460 1405 1355 Red Alt Cooling. Do not use for heating 1530 1 1475 1425 1360 1300 1240 1175 1115 1055 1000 Gray 5, 6 Cooling. Do not use for heating 2310 2255 2205 2155 2105 2055 2005 1955 1910 1885 Blue 5,6 Heating or alt Cooling 2065 2020 1970 1915 1860 1805 1740 1690 1635 1580 6612OE24 Yellow 5,6 Alt Cooling or alt Heating 1850 1800 1745 1690 1640 1585 1530 1475 1420 1360 Orange Alt Cooling. Do not use for heating 1500 1440 1380 1320 1260 1205 1145 1085 1035 955 Red Alt Cooling. Do not use for heating 1070 960 875 805 710 630 560 490 420 355 Gray 5, 6 Cooling. Do not use for heating 2505 2465 2425 2370 2310 2250 2180 2090 1955 1810 Blue 5,6 Heating or alt Cooling 2180 2130 2085 2035 1990 1945 1900 1850 1800 1755 6614OE24 Yellow 5,6 Alt Cooling or alt Heating 1910 1855 1810 1760 1705 1655 1605 1555 1505 1460 Orange Alt Cooling. Do not use for heating 1 1560 1 1505 1 1445 1380 1 1325 1265 1 1210 1155 1100 1040 Red 7 Alt Cooling. Do not use for heating 1 855 1 760 1 665 565 1 470 385 1 305 NOTE 1. A filter is required for each retum-air inlet. Airflow performance includes a 3/4-in. (19 mm) washable filter media (see accessory list). To determine airflow performance without this filter, assume an additional 0.1 in. w.c. available external static pressure. 2. ADJUST THE BLOWER SPEED TAPS AS NECESSARY FOR THE PROPER AIR TEMPERATURE RISE FOR EACH INSTALLATION. 3. The "Function" column identifies which speed taps can be used for heating. 4. If the same motor speed tap is needed for heating and cooling a Jumper Wire accessory kit is available, see Product Data accessories for the current Jumper Wire accessory part number. Reference the "Start-up, Adjustments, and Safety Check" section of installation instructions for further Jumper Wire instructions. 5. Airflows over 1800 CFM require bottom return, two -side return, or bottom and side return. A minimum filter size of 20" x 25" (508 x 635 mm) is required. 6. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return. 7. The "-" entry indicates an unstable operating condition. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 915SB: Product Data DIMENSIONAL DRAWING 61s16 - NOTES: 118''I �A 1. Doors may vary by model. 2. Minimum return -air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters. ICI a. For 800 CFM-16-in. (406 mm) round or 14 1/2 x 12-in. (368 x 305 mm) rectangle. VENT b. For 1200 CFM-20-in. (508 mm) round or 14 1/2 x 19 1/2-in. (368 x 495 mm) rectangle. c. For 1600 CFM-22-in. (559 mm) round or 14 1/2 x 22 1/16-in. (368 x 560mm) rectangle. D d. Return air above 1800 CFM at 0.5 in. w.c. ESP on 24.5" casing, requires one of the following 03 configurations: 2 sides, 1 side and a bottom or bottom only. See Air Delivery table in this H�TAIR document for specific use to allow for sufficient airflow to the furnace. Top VIEW 811/18 3. Vent and Combustion air pipes through blower compartment must I� 29 n79.+1 use accessory "Vent Kit - Through the Cabinet". See accessory list for 1749.31 current part number. 28314- 235/t6 15M91 20 518 - ]522.7] 791/8 1485.8]]0 AIR FLOW HORIZONTAL CONDENSATE DMN TRAP LOCATION e_ a.21 SIDE INLET 072 -I THERMOSTAT ENTRY I - t Will SIDES) 126A] 22 1656a] (BOTH SIDES) 21 15s4.01 A 03 I762I JUR INTAKE OUTLET WIDTH Q sI8 013144+It6'6]1 AIRFLOW OAS CONN r I78l VENT $h72 122.21POWER CONN 268n8 rns.91 a2 [so 2014 za me 189H8 Ista.9] Isa6.e] 25a/16 1420s1 [ea9.t1 227N78 2852 r26.41 141a118 171116 1a75.a1 14�2] 1667.91 \-SEE NOTE Ba III 6 • III 15ta.e] i F'"a 1480-9l -I_ C - -11n8 B7n8 BOTTOM RETURN 117.51 ]156A] WIDTH NOTE: ALL DIMENSIONS IN INCH 1MMI 16 28 3118 ]Me 2115n6 [667.41 211n8 law .81 20 s/8 1622.71 Q AIR FLAW DRAM TRAP LOCATION 2 .2] POWER CONN SIDE INLET IITTYY 1����I4J61I THEVAT ENM A180203 FURNACE SIZE A B C D SHIP WT. CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE LB (KG) 30026E14 14-3/16 (361) 12-1/2 (319) 12-9/16 (322) 7-1/8 (181) 118.0 (53.5) 3004OE14 14-3/16 (361) 12-1/2 (319) 12-9/16 (322) 7-1/8 (181) 120 (54.4) 3604OE17 17-1/2 (445) 15-7/8 (403) 16 (406) 8-3/4 (222) 126.5 (57.4) 36060E14 14-3/16 (361) 12-1/2 (319) 12-9/16 (322) 7-1/8 (181) 129 (58.5) 4206OE17 17-1/2 (445) 15-7/8 (403) 16 (406) 8-3/4 (222) 138.5 (62.8) 4808OE17 17-1/2 (445) 15-7/8 (403) 16 (406) 8-3/4 (222) 146.5 (66.5) 6008OE21 21 (533) 19-3/8 (492) 19-1/2 (495) 10-1/2 (267) 154.5 (70.1) 60100E21 21 (533) 19-3/8 (492) 19-1/2 (495) 10-1/2 (267) 164.5 (74.6) 66100E21 21 (533) 19-3/8 (492) 19-1/2 (495) 10-1/2 (267) 164.5 (74.6) 6612OE24 24-1/2 (622) 22-7/8 (581) 23 (584) 12-1/4 (311) 179.5 (81.4) 6614OE24 24-1/2 (622) 22-7/8 (581) 23 (584) 12-1/4 (311) 189 (85.7) Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10 915SB: Product Data IMFXAIMV]MF-l"XIIII]I►I%1 31111 :8W:/1019411V/4ki111i"4ki[CAN:I Maximum Allowable Exposed Vent Lengths in Unconditioned Space Insulation Table - Ft. Unit 26,000- BTUH Size Uninsulation 3/8-in. Insulation 1/2-in. Insulation Winter Design Pipe Dia. in. 1 1/2 2 1 1/2 2 1 1/2 2 Temp 20 20 20 50 45 60 50 OF 0 5 5 25 20 30 25 -20 15 10 20 15 -40 10 5 15 10 Winter Design Unit Size 40,000" BTUH 1111111 60,000 BTUH Uninsulated 3/8-in. Insulation 1/2-in. Insulation Uninsulated 3/8-in. Insulation 1/2-in. Insulation Pipe Dia. in. 1 1/2 2 2 1/2 1 '/2 2 2 1/2 1 1/2 2 2 1/2 1 1/2 2 2 1/2 3 1 1/2 2 2 1/2 3 1 '/2 2 2 1/2 3 Temp°F 20 20 20 20 20 50 45 20 60 50 20 30 30 25 20 75 65 60 20 85 75 65 0 10 5 5 20 25 20 20 30 25 15 15 10 10 20 40 30 25 20 45 40 30 -20 5 20 15 10 20 20 15 10 5 20 25 20 15 20 30 25 20 -40 15 10 5 15 15 10 5 1 20 15 15 10 20 20 15 10 80,000 BTUH Unit Size Uninsulated 3/8-in. Insulation 1/2-in. Insulation Winter Pipe Dia. in. 1 1/2 2 2'/2 3 4 1 '/2 2 2% 3 4 1 '/2 2 2'/2 3 4 Design 20 15 40 40 35 30 15 50 90 75 65 15 50 70 70 70 Temp °F 0 15 20 15 10 5 15 50 45 35 30 15 50 50 40 35 -20 15 10 5 15 35 30 20 15 15 40 30 25 15 -40 10 5 15 25 20 15 5 15 30 25 20 10 Winter Design Unit Size 100,000 BTUH 120,000 BTUH Uninsulated 3/8-in. Insulation 1/2-in. Insulation Uninsulated 3/8-in. Insulation 1/2-in. Insulation Pipe Dia. in. 2 2 1/2 3 4 2 21/2 3 4 2 21/2 3 4 21/2 F3T4 21/2 3 4 2 1/2 3 4 Temp OF 20 20 50 40 35 20 80 95 80 20 80 105 90 10 50 40 10 75 95 10 75 105 0 20 20 15 10 20 55 45 35 20 65 55 45 10 20 15 10 55 45 10 65 50 -20 15 10 5 20 35 30 20 20 45 35 25 10 10 10 35 25 10 45 30 -40 10 5 20 25 20 10 20 30 25 15 10 5 10 25 15 10 30 20 Unit Size 140,000 BTUH Uninsulated 3/8-in. Insulation 1/2-in.Insulation Winter Design Pipe Dia. in. 2'/2 3 4 2 1/2 3 4 2'/2 3 4 Temp OF 20 5 55 50 5 65 105 5 65 125 0 5 25 15 5 65 50 5 65 60 -20 5 10 5 5 45 30 5 50 40 -40 5 5 5 30 20 5 35 25 *. Not all model families have this size. Maximum Allowable Exposed Vent Length in Unconditioned Space - Meters Unit Size 26,000- BTUH Uninsulation 3/8-in. Insulation 1/2-in. Insulation Winter Design Pipe Dia. mm 38 51 38 51 38 51 Temp -7 6.1 6.1 15.2 13.7 18.3 15.2 °C -18 1.5 1.5 7.6 6.1 9.1 7.6 -29 4.6 3.0 6.1 4.6 -40 3.0 1.5 4.6 3.0 Unit Size 40,000 BTUH 60,000 BTUH Uninsulated 3/8-in. Insulation 1/2-in. Insulation Uninsulated 3/8-in.Insulation 1/2-in.Insulation Winter Design Pipe Dia. mm 38 51 64 38 51 64 38 51 64 38 51 64 76 38 51 64 76 38 51 64 76 Temp °C -7 6.1 6.1 6.1 6.1 15.2 13.7 6.1 18.3 15.2 6.1 9.1 9.1 7.6 6.1 22.9 19.8 18.3 6.1 25.9 22.9 19.8 -18 3.0 1.5 1.5 6.1 7.6 6.1 6.1 9.1 7.6 4.6 4.6 3.0 3.0 6.1 12.2 9.1 7.6 6.1 13.7 12.2 9.1 -29 1.5 6.1 4.6 3.0 6.1 6.1 4.6 3.0 1.5 6.1 7.6 6.1 4.6 6.1 9.1 7.6 6.1 -40 4.6 3.0 1.5 4.6 4.6 3.0 1.5 6.1 4.6 4.6 3.0 6.1 6.1 4.6 3.0 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 11 915SB: Product Data Unit 80,000 BTUH Size Uninsulated 3/8-in. Insulation 1/2-in. Insulation Winter Design Pipe Dia. mm 38 51 64 76 102 38 51 64 76 102 38 51 64 76 102 Temp *C -7 4.6 12.2 12.2 10.7 9.1 4.6 15.2 27.4 22.9 19.8 4.6 15.2 21.3 21.3 21.3 -18 4.6 6.1 4.6 3.0 1.5 4.6 15.2 13.7 10.7 9.1 4.6 15.2 15.2 12.2 10.7 -29 1 4.6 3.0 1.5 4.6 10.7 9.1 6.1 4.6 4.6 12.2 9.1 7.6 4.6 -40 1 3.0 1.5 4.6 7.6 6.1 4.6 1.5 4.6 9.1 7.6 6.1 3.0 Unit Size 100,000 BTUH 120,000 BTUH Uninsulated 3/8-in. Insulation 1/2-in. Insulation Uninsulated 3/8-in. Insulation 1/2-in. Insulation Winter Pipe Design Dia. 51 64 76 102 51 64 76 102 51 64 76 102 64 76 102 64 76 102 64 76 102 Temp mm °C -7 6.1 15.2 12.2 10.7 6.1 24.4 28.9 24.4 6.1 24.4 32.0 27.4 3.0 15.2 12.2 3.0 22.9 28.9 3.0 22.9 32.0 -18 6.1 6.1 4.6 3.0 6.1 16.8 13.7 10.7 6.1 19.8 16.7 13.7 3.0 6.1 4.6 3.0 16.8 13.7 3.0 19.8 15.2 -29 4.6 3.0 1.5 6.1 10.7 9.1 6.1 6.1 13.7 10.7 7.6 3.0 3.0 3.0 10.7 7.6 3.0 13.7 9.1 -40 3.0 1.5 6.1 7.6 6.1 3.0 6.1 9.1 7.6 4.6 3.0 1.5 3.0 7.6 4.6 3.0 9.1 6.1 Unit Size 140,000* BTUH* Uninsulated 3/8-in. Insulation 1/2-in. Insulation Winter Design Temp Pipe Dia. mm 64 76 102 64 76 102 64 76 102 °C -7 1.5 16.7 15.2 1.5 19.8 32.0 1.5 19.8 38.1 -18 1.5 7.6 4.6 1.5 19.8 15.2 1.5 19.8 18.3 -29 1.5 3.0 1.5 1 1.5 13.7 9.1 1.5 15.2 12.2 -40 1.5 1 1.5 1 1 1.5 9.1 6.1 1 1.5 1 35 1 7.6 *. Not all model families have this size. MAXIMUM EQUIVALENT VENT LENGTH - Ft. (M) NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application. Unit Size 26,000 2 40,0001 60,0002 80,000 100,0003 120,000 140,000 3 Pipe 1'h 2 1%: 2 21/: ;/ 2 2% 3 1% 2 2% 3 4 2 2% 3 4 2% 3 4 21h 3 4 (In)Dia. 0-2000 70 200 40 155 185 20 100 175 200 15 55 130 175 200 20 80 175 200 10 75 185 5 65 155 2001-3000 65 190 35 150 175 95 165 185 49 125 165 185 15 75 165 185 70 175 1 60 140 3001-4000 60 175 30 135 160 16 90 155 175 115 155 175 155 175 5 65 165 120 4001-4500 55 160 25 130 155 85 150 170 44 110 150 165 70 170 160 50 110 Altitude 10 4501-5000 125 145 80 145 165 145 160 65 150 165 45 100 (feet) 15 10 60 5001-6000 50 145 20 120 330 75 140 155 41 100 135 150 140 155 155 35 80 N/A 6001-7000 45 135 15 110 120 13 70 130 145 38 90 125 140 60 135 145 50 140 30 65 N/A 7001-8000 40 120 10 100 110 10 65 120 135 36 120 125 55 125 135 46 130 25 45 8001-9000 35 110 90 95 5 60 115 125 33 80 110 115 50 115 125 43 120 15 30 N/A N/ A 9001-10000 30 95 5 80 85 A 55 105 115 30 75 100 105 45 100 115 39 115 10 15 Maximum Equivalent Vent Length - Meters Unit Size 26,000 2 40,000 1 60,000 2 80,000 1100,000 3 120,000 140,0003 Pipe Dia. 38 51 38 51 64 38 51 64 76 38 51 64 76 102 51 64 76 102 64 76 102 64 76 102 (mm) 0-610 21.3 60.9 12.1 47.2 56.3 6'0 30.4 53.3 60.9 4.5 16.7 39.6 53.3 60.9 6.0 24.3 53.3 60.9 3'0 22.8 56.3 1.5 19.8 47.2 611-914 19.8 57.9 10.6 45.7 53.3 28.9 50.2 56.3 14.9 38.1 50.2 56.3 4.5 22.8 50.2 56.3 21.3 53.3 18.2 42.6 915-1219 18.2 53.3 9.1 41.1 48.7 4.8 27.4 47.2 53.3 35.0 47.2 53.3 47.2 53.3 1.5 19.8 50.2 36.5 1220-1370 16.7 48.7 7.6 39.6 47.2 25.9 45.7 51.8 13.4 33.5 45.7 50.2 21.3 51.8 48.7 15.2 33.5 Altitude 3.0 1371-1524 38.1 44.1 24.3 44.1 50.2 44.1 48.7 45.7 50.2 13.7 30.4 (meters) 4.5 18.2 3.0 19.8 NA 1525-1829 15.2 44.1 6.0 36.5 39.6 22.8 42.6 47.2 12.4 30.4 41.1 45.7 42.6 47.2 47.2 10.6 24.3 NA 1830-2134 13.7 41.1 4.5 33.5 36.5 3.9 21.3 39.6 44.1 11.5 27 4 38.1 42.6 18.2 41.1 44.1 15.2 42.6 9.1 19.8 2135-2438 12.1 36.5 3.0 30.4 33.5 3.0 19.8 36.5 41.1 10.9 36.5 38.1 16.7 38.1 41.1 14.0 39.6 7.6 13.7 NA 2439-2743 10.6 33.5 27.4 28.9 1.5 18.2 35.0 38.1 10.0 24.3 33.5 35.0 15.2 35.0 38.1 13.1 36.5 4.5 9.1 NA 2744-3048 9.1 28.9 1.5 24.3 25.9 NA 16.7 32.0 35.0 9.1 22.8 30.4 32.0 13.7 30.4 35.0 11.8 35.0 3.0 4.5 1. 40K Inducer Outlet Restrictor disk (P/N 337683-401; 1.25-in. (32 mm) Dia.) shipped in the loose parts bag or available through Replacement Components required under 10-ft. (3 M) TEVL in all orientations. Required for installations from 0 - 2000 ft. (0 to 610 M) above sea level. Failure to use an outlet restrictor may result in flame disturbances or flame sense lock -out. 2. 26K (shipped in loose parts bag) & 60K Inducer Outlet Restrictor disk (P/N 337683-401; 1.25-in. (32 mm) Dia. available through Replacement Components) required for less than 5-ft. (1.5 M) TEVL in downflow and horizontal orientations only. Required for installations from 0 - 2000 ft. (0 to 610 M) above sea level. 3. 120K & 140K Inducer Outlet Restrictor disk (P/N 337683-402; 1.50-in. (38 mm) Dia. available through Replacement Components) required for less than 5-ft. (1.5 M) TEVL in downflow and horizontal orientations only. Required for installations from 0 - 2000 ft. (0 to 610 M) above sea level. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 12 915SB: Product Data ELBOW CONFIGURATIONS Long Medium Mitered VENTTERMINAL CONFIGURATIONS Concentric Standard 2-in., 3-in., or optional 4-in. termination. Deductions from Maximum Equivalent Vent Length - Ft. (M) A13110 Pipe Diameter (in): 1-1/2 2 2-1/2 3 4 Mitered 901 Elbow 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) Medium Radius 900 Elbow 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) Long Radius 901 Elbow 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) Mitered 450 Elbow 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) Medium Radius 450 Elbow 2.5 (0.8) 2.5 (0.8) 2.5 (0.8) 2.5 (0.8) 2.5 (0.8) Long Radius 450 Elbow 1.5 (0.5) 1.5 (0.5) 1.5 (0.5) 1.5 (0.5) 1.5 (0.5) Tee 1 16 (4.9) 16 (4.9) 16 (4.9) 16 0 (0.0) 0 (4.9) 16 (4.9) Concentric Vent Termination 0 0 (0.0) (0.0) 0 (0.0) (0.0) 0 (0.0) Standard Vent Termination 0 (0.0) NOTE: 1.Use only the smallest diameter pipe possible for venting. Over -sizing may cause flame disturbance or excessive vent terminal icing or freeze-up. 2. NA - Not allowed. Pressure switch will not close, or flame disturbance may result. 3. Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by local authorities having jurisdiction. 4. Size both the combustion air and vent pipe independently, then use the larger size for both pipes. 5. Assume the two 45 ° elbows equal one 90' elbow. Wide radius elbows are desirable and may be required in some cases. 6. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count. 7. The minimum pipe length is 5 ft. (2 M) linear feet (meters) for all applications. 8. Use 3-in. (76 mm) diameter vent termination kit for installations requiring 4-in. (102 mm) diameter pipe Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 13 915SB: Product Data Venting System Length Calculations The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Deductions from Maximum Equivalent Vent Length - Ft. (M) Table. Standard vent terminations or factory accessory concentric vent terminations count for zero deduction. See vent system manufacturer's data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that one foot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe. Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Maximum Equivalent Vent Length Table. Example 1 A direct -vent 60,000 BTUH furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE: 70 feet (22 M) of vent pipe, 65 feet (20 M) of combustion air inlet pipe, (3) 90' long -radius elbows, (2) 45' long -radius elbows, and a factory accessory concentric vent kit. Can this application use 2" (50 mm ND) PVC/ABS DWV vent piping? Measure the required linear length of air inlet and vent 1 70 ft. Use length of the longer of the vent pipe; insert the longest of the two here (22 M) or air inlet piping system Add equiv length of (3) 900 long -radius elbows 3 ft. 9 ft. From Deductions from Maximum Equivalent (use the highest number of elbows for either the vent or 3 x (0.9 M) _ (2.7 M) Vent Length - Ft. (M) Table. inlet pipe) Add equiv length of (2) 450 long -radius elbows 1.5 ft. 3 ft. From Deductions from Maximum Equivalent (use the highest number of elbows for either the vent or 2 x (0.5 M) _ (0.9 M) Vent Length - Ft. (M) Table. inlet pipe) Add equiv length of factory concentric vent term 0 ft. From Deductions from Maximum Equivalent Vent Length - Ft. (M) Table. Add correction for flexible vent pipe, if any 0 ft. From Vent Manufacturer's instructions; zero for PVC/ABS DWV Total Equivalent Vent Length (TEVL) (82 M) Add all of the above lines Maximum Equivalent Vent Length (MEVL) 95 ft. For 2" pipe from Maximum Equivalent Vent (29 M) Length Table. Is TEVL less than MEVL? YES Therefore, 2" pipe MAY be used Example 2 A direct -vent 60,000 BTUH furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE: 100 feet (30 M) of vent pipe, 95 feet (29 M) of combustion air inlet pipe, (3) 90' long -radius elbows, and a polypropylene concentric vent kit. Also includes 20 feet (6.1 M) of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe. VERIFY FROM POLYPROPYLENE VENT MANUFACTURER'S INSTRUCTIONS for the multiplier correction for flexible vent pipe. Can this application use 60mm o.d. (2") polypropylene vent piping? If not, what size piping can be used? Measure the required linear length of RIGID air inlet and vent pipe; insert the longest of _ 80 ft. Use length of the longer of the vent the two here: 100 ft. Of rigid pipe - 20 ft. Of flexible pipe (24 M) or air inlet piping system Add equiv length of (3) 901 long -radius elbows (use the 3 x 5 ft. _ 15 ft. highest number of elbows for either the vent or inlet pipe) (1.5 M) (4.6 M) Add equiv length of 451 long -radius elbows (use the highest number of elbows for either the vent or 0 x = (� M) Example from polypropylene vent inlet pipe) manufacturer's instructions, Verify from vent manufacturer's instructions. Add equiv length of factory concentric vent term g x 3.3 ft _ 30 ft. (0.9 M) (9 M) Add correction for flexible vent pipe, if any 2" x 20 ft. (6.1 M) = 40 ft. (12.2 M) * VERIFY FROM VENT MANUFACTURER'S INSTRUCTIONS; For example only, assume 1 meter of flexible 60mm (2") or 80mm (W) polypropylene pipe equals 2.0 meters (6.5 ft.) of PVC/ABS pipe. Total Equivalent Vent Length (TEVL) 165 ft. (50 M) Add all of the above lines Maximum Equivalent Vent Length (MEVL) 95 ft. For 2" pipe from Maximum Equivalent Vent (29 M) Length Table. Is TEVL less than MEVL? NO Therefore, 60mm (2") pipe may NOT be used; try 80mm (Y) Maximum Equivalent Vent Length (MEVL) 185 ft. For 3" pipe from Maximum Equivalent Vent (57 M) Length Table. Is TEVL less than MEVL? YES Therefore, 80mm (3") pipe MAY be used Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 14 915SB: Product Data RETURN AIR TEMPERATURE 11161T ki I2X61T1Tj i11 3 7_1RI 4 This furnace is designed for continuous return -air minimum temperature of 60oF (15°C) db or intermittent operation down to 55°F (13°C) db such as when used with a night setback thermometer. Return -air temperature must not exceed 80°F (27°C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls. SUPPLY 32o F/ 0° C MINIMUM INSTAL AMBIENT OR FREEZE PROTECTION REQUIRED T MAX807 / 27'C -I MIN60OF / 16`C A 10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 (0 mm) Front (Combustion air openings in furnace and in structure) 1 in. (25 mm) Required for service 24 in. (610 mm)t All Sides of Supply Plenum* 1 in. (25 mm) Sides 0 (0 mm) Vent 0 (0 mm) Top of Furnace 1 in. (25 mm) *. Consult your local building codes �. Recommended COMBUSTION -AIR PIPE FOR NON -DIRECT (1-PIPE) VENT APPLICATION 2-IN. (51 mm) DIA. FIELD -SUPPLIED MITERED RADIUS 2-IN. (51 mm) DIA. PVC 90, ELBOW PVC PIPE f 12" (300 mm) MINIMUM A 12376 NOTE: See Installation Instructions for specific venting configurations. 1 1/4-IN. TYP PLENUM OPENING LOCATING TAB A97427 \ 1m 3m 40 \ D , LOCATING \ TAB bo 3m 2m �� A88207 Downfoow Subbase A88202 One base fits all furnace sizes. The base is designed to be installed between the furnace and a combustible floor when no coil box is used or when a coil box other than a Bryant cased coil is used. It is CSA design certified for use with Bryant branded furnaces when installed in downflow applications. DIMENSIONS (IN. / MM) FURNACE PLENUM OPENING FLOOR OPENING HOLE NO. FOR CASING FURNACE IN DOWN FLOW APPLICATION WIDTH WIDTH A B C D ADJUSTMENT 14-3/16 (360) Furnace with or without Cased Coil Assembly or 11-3/16 (322) 19 (483) 13-7/16 (341) 20-5/8 (600) 4 Coil Box 17-1/2 (445) Furnace with or without Cased Coil Assembly or 15-1/8 (384) 19 (483) 16-3/4 (426) 20-5/8 (600) 3 Coil Box 21 (533) Furnace with or without Cased Coil Assembly or 18-5/8 (396) 19 (483) 20-1/4 (514) 20-5/8 (600) 2 Coil Box 24-1/2 (622) Furnace with or without Cased Coil Assembly or 22-1/8 (562) 19 (483) 23-3/4 (603) 20-5/8 (600) 1 Coil Box *. The plenum should be constructed 1/4-in. (6 mm) smaller in width and depth than the plenum dimensions shown above. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 15 915SB: Product Data Concentric Vent Kit A93086 A concentric vent kit allows vent and combustion -air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn in through the outer pipe. MEDIA FILTER CABINET (OPTIONAL ACCESSORY) 23-518" 600mm) 23-3/8' 594mm) Centerline Screw Slots 25-5/8" (651mm) 24-114" Opening 61with6mmFla)nges Bent 23-1/8" (588mm) — O Opening A Ld Duct Side —I F5a/an (146mm) Media Filter Cabinet I A e 16" 406mm 17" 43 mm 16" 406mm 20" 508mm 21" 533mm 20.. 508mm 24" 610mm 25" 635mm 24" J610mmj NOTE: Media cabinet is matched to the bottom opening on furnace. May also be used for side return. A12428 TYPICAL WIRING SCHEMATIC ---- FIELD 24-V WIRING ---- FIELD 115-, 208/230-, 460-V WIRING FACTORY 24-V WIRING FACTORY 115-V WIRING NOTE 2 THERMOSTAT FIVE WIRE w e R G v TERMINALS FIELD -SUPPLIED THREE -WIRE I I I DISCONNECT HEATING -ONLY I I I BLOWER DOOR SWITCH --- 60-V 0- OR I I N •4 60-V I --- THREE BLK Bt_ V 0 i i i PHASE WH _____H C I I I I O I I ----�___-- N i i -- •---1 208/230-V =GND GND R G ___L_______j t— l SINGLE I ______I PHASE 115-V FIELD- AUXILIARY O _ I _ ___ I SUPPLIED J-BOX L coM ---- NOTE 1 _I j =GND DISCONNECT ---- -- CONDENSING Y-------------- UNIT 24-V TWO TERMINAL WIRE BLOCK FURNACE NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation. 2. Some thermostats require a "C" terminal connection as shown. 3. If any of the original wire, as supplied, must be replaced, use same tvoe or eauivalent wire. A 190079 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 16 915SB: Product Data GUIDE SPECIFICATIONS General System Description Furnish a 4-way multipoise gas -fired condensing furnace for use with natural gas or propane (factory - authorized conversion kit required for propane). Quality Assurance Unit will be designed, tested and constructed to the current ANSI Z 21.47/CSA 2.3 design standard for gas -fired central furnaces. Unit will be third party certified by CSA to the current ANSI Z 21.47/CSA 2.3 design standard for gas -fired central furnaces. Unit will carry the CSA Blue Star® and Blue Flame® labels. Unit efficiency testing will be performed per the current DOE test procedure as listed in the Federal Register. Unit will be certified for capacity and efficiency and listed in the latest AHRI Consumer's Directory of Certified Efficiency Ratings. Unit will carry the current Federal Trade Commission Energy Guide efficiency label. Delivery. Storage. and Handling Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Warranty (for inclusion by specifying engineer) U.S. and Canada only. Warranty certificate available upon request. Equipment Blower Wheel and ECM Blower Motor Galvanized blower wheel shall be centrifugal type, statically and dynamically balanced. Blower motor of ECM type shall be permanently lubricated with sealed ball bearings, of hp, and have multiple speeds from 600-1200 RPM operating only when 24-VAC motor inputs are provided. Blower motor shall be direct drive and soft mounted to the blower housing to reduce vibration transmission. Filters Furnace shall have reusable -type filters. Filter shall be in. (mm) X in. (mm). An accessory highly efficient Media Filter is available as an option. Media Filter. Casing Casing shall be of .030 in. thickness minimum, pre -painted steel. Draft Inducer Motor Draft inducer motor shall be single -speed PSC design. Primary Heat Exchangers Primary heat exchangers shall be 3-Pass corrosion -resistant aluminized steel of fold -and -crimp sectional design and applied operating under negative pressure. Secondary Heat Exchangers Secondary heat exchangers shall be of a stainless steel flow -through of fin -and -tube design and applied operating under negative pressure. Controls Controls shall include a micro -processor -based integrated electronic control board with at least 16 service troubleshooting codes displayed via diagnostic flashing LED light on the control, a self -test feature that checks all major functions of the furnace, and a replaceable automotive -type circuit protection fuse. Multiple operational settings available, including blower speeds for heating and cooling. Operating Characteristics Heating capacity shall be Btuh output capacity. Fuel Gas Efficiency shall be AFUE. Btuh input; Air delivery shall be cfin minimum at 0.50 in. W.C. external static pressure. Dimensions shall be: depth in. (mm); width (mm); height in. (mm) (casing only). be in. (mm) with A/C coil and overall with plenum. Electrical Requirements in. Height shall in. (mm) Electrical supply shall be 115 volts, 60 Hz, single-phase (nominal). Minimum wire size shall be AWG; maximum fuse size of HACR-type designated circuit breaker shall be amps. Special Features Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements. Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 17 915SB: Product Data © 2021 Carrier. All rights reserved. Edition Date: 04/21 Catalog No:PDS915SB-05 A Carrier Company Replaces:PDS915B-04 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 18 Submittal Data Job Data: I Location: Buyer: 1 7Buyer P.O. #:F Carrier #: Unit Number: I I Model Number: Performance Data Certified By: I IDate: 1-, NOTE: Images for illustration nurooses only. Actual models may be sliahtiv different. System Size 24 Outdoor Model 38MAQB24R--3 Electrical Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 MCA A. 20 MOCP - Fuse Rating A. 30 Operating Range Cooling Outdoor DB Min - Max °F °C -13-122 -25-50 Heating Outdoor DB Min - Max °F(°C) -22-86 (-30-30) Piping Total Piping Length ft m 164 50 Piping Lift ft (m) 65 (20) Pipe Connection Size - Liquid in mm 3/8 9.52 Pipe Connection Size - Suction in (mm) 5/8 (16) Refrigerant Refrigerant Type R410A Metering Device lCharge EEV I Ibs k 5.73 2.60 * Condensing unit above or below indoor unit For Compatibility See Product Data Accessories STANDARD FEATURES • Variable Speed (Inverter) • Factory installed Base Pan Heater • Factory installed Crankcase Heater • Low Voltage Controls • Auto -Restart function • Condenser High Temp Protection • Refrigerant Leakage Detection • Modes: Cool, Heat, Dry, Fan, Auto • Quiet operation • Anti -corrosive fin coating LIMITED WARRANTY* • 10 year limited to original purchaser on compressor and parts upon timely registration, otherwise 5 years *For residential applications. See warranty for full details. Outdoor Coil Face Area Sq. Ft. 8.0 No. Rows 2 Fins per inch 20 Circuits 4 Compressor Type Rotary Inverter Model ATF2351D22UMT Oil Type VG74 Oil Charge FI. Oz. 23.6 Rated Current RLA 14.0 Outdoor Unit Width in mm 37.24 946 Unit Height in (mm) 31.89 (810) Unit Depth in (mm) 16.14 410 Net Weight Ibs (kg) 145.5 (66) Airflow CFM 2,130 Sound Pressure dB(A) 60.5 RCD# 331831-701 Piping Adaptor Kit, to facilitate piping installation when matched with FMA/FMC/FMU RCD# 40MD000003 Piping Adaptor Kit, to facilitate piping installation when matched with FV4 Copyright 2020 CAC/BDP • Atlanta, GA. 30339 Edition Date: 07/2020 Catalog No: 38MAR-24-3-08SB SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces: 38MAR-24-3-07SB Performance t rn = Indoor Model 40MAQB24B--3 Indoor Model 619PEQ024BBMA Indoor Model DHMSHAQ24XA3 Energy Star YES Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 5,500-24,500 SEER 20.5 EER 13 Heating Rated Capacity (47°F) Btu/h 24,000 Heating Rated Capacity (17°F) Btu/h 15,400 Heating Maximum Capacity (17T) Btu/h 24,000 Heating Maximum Capacity (5°F) Btu/h 24,000 Heating Cap. Range Min - Max Btu/h 6,000-32,000 HSPF 11.5 COP (47°F) W/W 3.10 COP (17°F) W/W 2.64 COP (5°F) W/W 1.88 H �j Indoor Model 40MBCQ24 --- 3 Energy Star NO Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 8500-26500 SEER 20.0 EER 11 Heating Rated Capacity (47°F) Btu/h 24,000 Heating Rated Capacity (17T) Btu/h 16,200 Heating Maximum Capacity (17°F) Btu/h 24,000 Heating Maximum Capacity (5°F) Btu/h 24,000 Heating Cap. Range Min - Max Btu/h 13200-32000 HSPF 11.5 COP (47°F) W/W 3.46 COP (17T) W/W 2.73 COP (5°F) W/W 1.88 d 3 Indoor Model 40MBDQ24 --- 3 Energy Star YES Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 5,500-24,500 SEER 20.5 EER 12.5 Heating Rated Capacity (47°F) Btu/h 24,000 Heating Rated Capacity (17°F) Btu/h 17,200 Heating Maximum Capacity (17T) Btu/h 25,400 Heating Maximum Capacity (5°F) Btu/h 24,000 Heating Cap. Range Min - Max Btu/h 6,000-26,000 HSPF 12.5 COP (47°F) W/W 3.82 COP (17°F) W/W 2.56 COP (5°F) W/W 1.83 d 0 c v Indoor Model 40MBFQ24 --- 3 Energy Star NO Cooling Rated Capacity Btu/h 24,000 Cooling Cap. Range Min - Max Btu/h 8000-28150 SEER 20.0 EER 11.5 Heating Rated Capacity (47°F) Btu/h 24,000 Heating Rated Capacity (17T) Btu/h 17,200 Heating Maximum Capacity (17°F) Btu/h 26,600 Heating Maximum Capacity (5°F) Btu/h 26,560 Heating Cap. Range Min - Max Btu/h 20500-36750 HSPF 11.5 COP (47°F) W/W 3.52 COP (17T) I W/W 1 2.82 COP (5°F) I W/W 11.81 Backward compatible with 40MBQB*D Ducted Copyright 2020 CAC/BDP • Atlanta, GA. 30339 Edition Date: 07/2020 Catalog No: 38MAR-24-3-08SB SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces: 38MAR-24-3-07SB Performance Q Indoor Model 40MBAAQ24XA3 Energy Star YES Cooling Rated Capacity Btu/h 20,800 Cooling Cap. Range Min - Max Btu/h 6,000-23,000 SEER 20.0 EER 12.5 Heating Rated Capacity (47°F) Btu/h 29,000 Heating Rated Capacity (17°F) Btu/h 17,500 Heating Maximum Capacity (17T) Btu/h 29,700 Heating Maximum Capacity (5°F) Btu/h 26,970 Heating Cap. Range Min - Max Btu/h 6,000-30,000 HSPF 10.0 COP (47°F) W/W 3.48 COP (17°F) W/W 2.30 COP (5°F) Indoor Model W/W 2.10 — 0 c� c LL LL Energy Star NO Cooling Rated Capacity Btu/h 23,000 Cooling Cap. Range Min - Max Btu/h 7,900-36,500 SEER 14.5 EER 11.0 Heating Rated Capacity (47°F) Btu/h 24,000 Heating Rated Capacity (17T) Btu/h 15,800 Heating Maximum Capacity (17°F) Btu/h 28,900 Heating Maximum Capacity (5°F) Btu/h 28,700 Heating Cap. Range Min - Max Btu/h 11,600-36,500 HSPF 9.5 COP (47°F) W/W 3.80 COP (17°F) W/W 2.75 COP (5°F) W/W 2.30 o c� LL LL v LL Indoor Model FMC4Z2400AL Indoor Model FMU4Z2400AL Energy Star NO Cooling Rated Capacity Btu/h 23,000 Cooling Cap. Range Min - Max Btu/h 9,300-37,000 SEER 20.0 EER 12.2 Heating Rated Capacity (47°F) Btu/h 23,200 Heating Rated Capacity (17T) Btu/h 15,000 Heating Maximum Capacity (17°F) Btu/h 28,400 Heating Maximum Capacity (5°F) Btu/h 28,400 Heating Cap. Range Min - Max Btu/h 9,300-35,000 HSPF 11.2 COP (47°F) W/W 3.74 COP (17°F) W/W 2..74 COP (5°F) W/W 2.19 _ 0 LL LL Indoor Model F 14CNF002L00 Energy Star NO Cooling Rated Capacity Btu/h 23,000 Cooling Cap. Range Min - Max Btu/h 8,400-33,670 SEER 17.0 EER 11.5 Heating Rated Capacity (47°F) Btu/h 23,600 Heating Rated Capacity (17°F) Btu/h 14,000 Heating Maximum Capacity (17T) Btu/h 23,910 Heating Maximum Capacity (5°F) Btu/h 23,890 Heating Cap. Range Min - Max Btu/h 11,900-32,580 HSPF 10.5 COP (47°F) W/W 3.85 COP (17°F) W/W 2.70 COP (5°F) W/W 2.59 Applications with the FMA4, FMC, FMU and FV4 fan coils require the 24V interface 2nd Generation KSAIC0301230 and a Piping Adaptor Kit to facilitate piping installation when removing the TXV kit from the indoor unit Copyright 2020 CAC/BDP • Atlanta, GA. 30339 Edition Date: 07/2020 Catalog No: 38MAR-24-3-08SB SUBJECT TO CHANGE WITHOUT NOTICE Page 3 Replaces: 38MAR-24-3-07SB Construction View 31.91 in :810 rnr-�) 69F m 17.90 in(455 mm) 1 Outdoor Model: 38MAQB24R--3 in(959 mm) 7,3$ in(188 glgm 47 in(12 mm) r"l 38 mm) 09 mm) 6.49 in(673 mm)-�� .$7 in(73 mm) ------- 3,9--an(24 mm) 8.36 in(212 mm) 38 In(86 mm) 1.5,85 in(403 mm) Copyright 2020 CAC/BDP • Atlanta, GA. 30339 Edition Date: 07/2020 Catalog No: 38MAR-24-3-08SB SUBJECT TO CHANGE WITHOUT NOTICE Page 4 Replaces: 38MAR-24-3-07SB Ruud Residential Electric Professional Ultra Hybrid Water Heaters Professional Ultrd" Hybrid Electric with LeakGuardT"" is the most efficient water heater available Efficiency • Up to 4.0 UEF reduces operating cost • ENERGY STAR® rated Performance • Delivers hot water faster than most standard electric water heaters • Ambient operating range: 37-145' F is widest in class, offering more days of HP operation annually; designed to meet Northern Climate Spec (Tier 4) Easy Installation • Easy access side connections • Quick access to electrical junction box • Easily replaces a standard electric water heater Integration • LED Screen with built-in water sensor alert with audible alarm' • Integrated EcoNet® WiFi-connected2 technology and free mobile app gives users control over water heater, allowing for customizable temperature, vacation settings, energy savings and system monitoring at home or away. Visit Ruud.com/hybridsolutions • Integrated leak detection and prevention system with factory installed auto water shut-off valve limits leaks to no more than 20 ounces of water', 3 • LeakSense'M Built-in Leak Detection System detects any leak large or small, internal or external' 4 Operation Modes • Energy Saver • Heat Pump • High Demand • Electric • Vacation/Away: 2-28 days (or placed on hold indefinitely) Plus... • Premium grade anode rod with resistor extends the life of the tank • 3/4" NPT water inlet and outlet; 3/4" condensate drain connections • Incoloy stainless steel resistor elements • Dry -fire protection • Easy access, top mounted washable air filter • 2" Non-CFC foam insulation • Enhanced flow brass drain valve • Temperature and pressure relief valve installed • Design certified to NSF/ANSI 372 (Lead Content) Warranty • 10-Year limited tank and parts warranty See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. 'Available with select models. 2WiFi broadband internet connection required. 3Source: Ruud Leak -Sensing Data; testing under a vacuum lock using 50-gallon tank, no expansion tank, average tank pressure of 40 psi, assuming no additional faucets are opened. "Water leaks from the heater only, as tested across scenarios including a minimum of 5.5mUhr volume leak rate, using most common installation scenarios. Professional Ultra Hybrid 40, 50, 65 and 80-Gallon Capacities 208-240 Volt / 1 PH Electric C UL US 0) 1101111111111111 LEED Points = 3 See specifications chart on next page. Ruud Water Heating • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076 • www.ruud.com Professional UltraT" Hybrid Specifications Mpt. GALLON GALLON CAPACITY CAPACITY 40 36 DESCRIPTIO��WENERGY MODEL MODEL ", �q NUMBER VARIANT E PROU H40 T2 RU375-SO 700656 30 INFO Fo OR RM ER.1 YEARLY SOUND TOR ENERGY COMPRESSOR LEVEL U OST BTU/H __(dBA) 30 Amp with LeakGuard 3.75 $104 4,200 49 FIRST HR, R NG G.P.H. 60 FEATURES RECOVERY IN G,P.H 90' F RISE 26 1=��UH ELEMENT WATTAGE 4,500 TOTAL11lllllllllllllllll�RNIT UNIT MAX WATTAGE AMPS 5,000 21 WEIGHTS WT. (LBS) 157 PIPING APPROX. SHIP WT. (LBS.) 174 50 45 PROUH50 T2 RU375-SO 700647 30 3.75 $104 4,200 49 67 27 4,500 5,000 21 178 218 65 59 PROUH65 T2 RU375-SO 700648 30 3.85 $155 4,200 49 75 27 4,500 5,000 21 225 262 80 72 PROUH80 T2 RU375-SO 700655 30 4.00 1 $149 Amp without 4,200 LeakGuard 49 87 27 4,500 5,000 21 244 281 40 36 PROUH40 T2 RU375-30 700493 30 3.75 $104 4,200 49 60 27 4,500 5,000 21 157 174 50 45 PROUH50 T2 RU375-30 700471 30 3.75 $104 4,200 49 67 27 4,500 5,000 21 178 218 65 59 PROUH65 T2 RU375-30 700472 30 3.85 $155 4,200 49 75 27 4,500 5,000 21 225 262 80 72 PROUH80 T2 RU375-30 700492 30 4.00 $149 4,200 49 87 27 4,500 5,000 21 244 281 40 36 PROUH40 T2 RU375-15 700487 15 15 3.45 Amp without $78 LeakGuard 4,200 49 46 16 2,250 2,750 12 157 174 50 45 PROUH50 T2 RU375-15 700479 15 3.75 $104 4,200 49 52 16 2,250 2,750 12 178 218 65 59 PROUH65 T2 RU375-15 700485 15 3.55 $110 4,200 49 54 16 2,250 2,750 12 225 262 80 72 PROUH80 T2 RU375-15 700486 15 3.70 $105 4,200 49 67 16 2,250 2,750 12 244 281 Estimated energy cost based on a national average electricity cost of $0.12 /kWh. Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. All units have integrated WiFi control board. 2" Clearance Needed for T&P Release F � o • G B C I I E 40 PROUH40 62-5/16 20-1/4 4773-r5/839-5/8 23-3/8 20-1/2 78-7/8 22-3/8 23-1/4 50 PROUH50 61-3/4 22-1/4 47 3-5/8 39-5/8 25-3/8 22-1/2 78-5/8 24-3/8 25-9/16 65 PROUH65 64-3/16 24-1/4 49 3-7/8 42-3/8 27-1/2 24-5/8 81-1/8 26-1/2 27-3/8 80 PROUH80 74-3/16 24-1/4 59 3-7/8 42-3/8 27-1/2 24-5/8 91 26-1/2 27-3/8 Hybrid Water Heater Installation Guidelines to Provide Optimal Efficiency Heater: Not Ducted Room size: Larger than 700 ft3 (e.g. Tx 10' x 10'). Requirements: No additional ventilation needed. 24" Heater: Not Ducted Room size: Smaller than 700 ft3 (e.g. Tx 10' x 10'). Requirements: Full louvered door OR two louvers top and bottom. See below. Heater: Not ducted Room: Small Closet Requirements: * Air gap under door equal to 18 in (0.75" clearance). * Louver must be located the same height on door as the air exhaust on heater. Heater air exhaust must be positioned towards louver within one foot of door. Heater: Ducted with inlet OR outlet duct Room size: Any size room Requirements: Air gap under door equal to 18 in (0.75" clearance) Air exhaust f 12"Max Door Heater: Ducted with inlet AND outlet duct Room size: Any size room Requirements: No additional ventilation needed. 75" 3 Ruud Residential Electric Professional Ultra Hybrid Water Heaters RU Hybrid Accessories List Leak Sensor Automatic detection of internal and external leaks Shutoff Valve Automatic shut off of water supply to unit Inlet Duct Adapter Allows for ducting to be connected on the top inlet Outlet Duct Adapter Allows for ducting to be connected to the unit Earthquake Isolation Kit Installations in seismic regions Vibration Isolation Kit Installation on non -concrete floors 8" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 8" diameter 7" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 7" diameter 6" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 6" diameter 5" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 5" diameter 8" Ruud Approved Damper Kit Exhaust only to the outside ducting configuration (no inlet duct) 25' Flexible 8" Diameter Duct Kit For up to 25' of ducting Rigid Elbow Duct Kit UPGRADE Installation in tight places where space needs to be minimized Leak Sensor & Shutoff Valve Kit Upgrade 15 and 30 Amp models to protect your customers home from water damage with leak detection and auto shutoff valve Leak Sensor Earthquake Isolation Kit 6" Diameter UL Certified Termination Kit 0* Rigid Elbow Duct Kit Shutoff Valve Vibration Isolation Kit 4� 5" Diameter UL Certified Termination Kit 71eak for models ard only) - or and shuttoff from water Inlet Duct Adapter 8" Diameter UL Certified Termination Kit 8" Ruud Approved Damper Kit In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. Outlet Duct Adapter 7" Diameter UL Certified Termination Kit vroki 25' Flexible 8" Diameter Duct Kit Ruud Water Heating • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076 • www.ruud.com