APPROVED BLD PLN FIR-BLD2023-0686+Architectural_Plan+6.2.2023_9.51.46_AM+3583768ABBREVIATIONS:
ADJ. ADJUSTABLE
A/C AIR CONDITIONING
ACT. ALTERNATE
A.B. ANCHOR BOLT
ABV. ABOVE
A.F.F. ABOVE FINISHED FLOOR
ARCH. ARCHITECTURAL
AUTO. AUTOMATIC
ASPH. ASPHALT
BM. BEAM
BRG. BEARING
BET. BETWEEN
B.L. BUILDING LINE
BLK. BLOCK
BLKG. BLOCKING
BD. BOARD
BOY. BOTTOM
BLDG. BUILDING
CAB. CABINET
CPT. CARPET
CLG. CEILING
CLG. HT. CEILING NEIGNT
CEM. CEMENT
CTR. CENTER
C.T. CERAMIC TILE
CLR. CLEAR (ANCE)
CLO. CLOSET
COL. COLUMN
CONC. CONCRETE (CAST -IN -PLACE)
COMB. COMBUSTION
CMU CONCRETE MASONRY UNIT
CONST. CONSTRUCTION
CONY. CONTINUOUS OR CONTINUE
CJT. CONTROL JOINT
CORR. CORRIDOR
C.W. COLD WATER
CIR. CIRCLE
CLKG CAULKING
C.J. CEILING JOIST
CSMT CASEMENT WINDOW
DET. DETAIL
DIAG. DIAGONAL
DIA. DIAMETER
DIF. DIFFUSER
DIM. DIMENSION
DISP. DISPENSER
DR. DOOR
DW. DISNWASNER
DWR DRAWER
DWG. DRAWING
DIV. DIVISION
DN. DOWN
DS. DOWNSPOUT
ELEC. ELECTRICAL
EA. EACH
EQ. EQUAL
EQUIP. EQUIPMENT
EXH. EXHAUST
EXIST. EXISTING
EXT. EXTERIOR
FIN. FINISH
FLR FLOOR
F.D. FLOOR DRAIN
F.B. FLOOR BREAK
FLUOR. FLUORESCENT
FT. FOOT
FTC. FOOTING
FND. FOUNDATION
FURR. FURRED (ING)
FUT. FUTURE
FR. FRENCH
F.A.U. FORCED AIR UNIT
F.O.S. FACE OF STUD
F.G. FINISH GRADE
F.S. FREE STANDING
F.J. FLOOR JOIST
G.A. GAUGE
GALV. GALVANIZED
G.C. GENERAL CONTRACTOR
GL. GLASS, GLAZING
GL. BLK. GLASS BLOCK
GYP. BD. GYPSUM BOARD
GYP. GYPSUM
G.I. GALVANIZED IRON
GWB. GYPSUM BOARD
HOW. HARDWARE
NOR. HEADER
H.V.A.C. HEATING/VENTING/
AIR CONDITIONING
HT. (HGT.) NEIGNT
N.C. HOLLOW CORE
N.M. HOLLOW METAL
HORIZ. HORIZONTAL
N.B. NOSE BIBS
HR. HOUR
HYD. HYDRANT
IN. INCH
INCL. INCLUDE (ED) (ING)
INSUL. INSULATE
INT. INTERIOR
KIT. KITCHEN
LAM. LAMINATE
LAV. LAVATORY
LAUN. LAUNDRY
LVR. LOUVER
LTG. LIGHTING
LT. LIGHT
M.B. MACHINE BOLT
MFR. MANUFACTURE (R)
MAS. MASONRY
M.O. MASONRY OPENING
MATL. MATERIAL
MAX. MAXIMUM
MECH. MECHANIC (AL)
MED. MEDIUM
MEMB. MEMBRANE
MTL. METAL
MIR. MIRROR
MISC. MISCELLANEOUS
MIN. MINIMUM
MLD. MOLDING
N.T.S. NOT TO SCALE
OFF. OFFICE
O.C. ON CENTER
O.N. OVER HEAD
O.N.C. OVER HEAD CABINET
O.N.D. OVER HEAD DOOR
OPG. OPENING
OPT. OPTION, OPTIONAL
OBS. OBSCURE
PIC PICTURE WINDOW
PNL. PANEL
P.BD. PARTICLE BOARD
PL. PLATE
PLWD. PLYWOOD
PVC. POLYVINYL CHLORIDE
P.S.F. POUNDS PER SQUARE FOOT
P.S.I. POUNDS PER SQUARE INCH
P.L. PROPERTY LINE
PR. PAIR
RAD. RADIUS
REF. REFERENCE
REINF. REINFORCE (D) (ING)
RM. ROOM
R.O. ROUGH OPENING
SCH. SCHEDULE
SHY. SHEET
SIM. SIMILAR
S.C. SOLID CORE
S.G. (or SG) SAFETY (TEMPERED) GLASS
SGD SLIDING GLASS DOOR
SGL. SINGLE
SPEC. SPECIFICATION
SQ. SQUARE
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRUCT. STRUCTURAL
SIM. SIMILAR
SYS. SYSTEf1
SHTG. SHEATING
TEL. TELEPHONE
T.V. TELEVISION
TEMP. TEMPERED
THRES. THRESHOLD
TAG TONGUE AND GROOVE
T.o.s. TOP of sLAB
T.O.P. TOP OF PLATE
TYP. TYPICAL
T.BM. TOP OF BEAM
TPL. TOP PLATE
U.N.O. UNLESS NOTED OTHERWISE
VEST. VESTIBULE
VYL VINYL COMPOSITION TILE
V.I.F. VERIFY IN FIELD
W.C. WATER CLOSET
WP. WATER PROOFING
w/ WITH
WIN. WINDOW
w/o WITHOUT
WD. WOOD
WAD WASHER AND DRYER
W.I. WROUGHT IRON
W.N. WATER HEATER
W.R.G.B. WATER RESISTANT
GYPSUM BOARD
W/S WIRE SHELF
APPROVED BY PLANNING
�� � ;/
u i 4 rF G� •ri.�
i L
c�
Jul 24 2023
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
•
0
Pacific Ridge Series "'
F'��,�I N�,ME
r- — - — - — - — - — - — - — - — - — -
I SEPARATE PLUMBING PERMIT ,
REQUIRED FOR THIS PROJECT.
L-------------------
APPROVED
PLANS MUST BE
ON JOB SITE
PR�I INTERNAL PLAN
NAIL I NG LEGEND
PLAN NAME LETTERS:
FOUNDATION TYPE:
F =FLAT (2-STORY, 3-STORY,
TALL CRAWL)
D = "DAYLIGHT" BASEMENT
T = "TUCK -UNDER" GARAGE
LAST NUMBER OF CODE CYCLE
YEAR:
(2018, 2021, ETC. )
CODE REFERENCES
INTERNATIONAL RESIDENTIAL CODE: 2018
INTERNATIONAL MECHANICAL CODE: 2018
INTERNATIONAL FIRE CODE: 2018
UNIFORMED PLUMBING CODE: 2018
WASHINGTON STATE ENERGY CODE: 2018
ANSI/AF � PA SDPWS 2018
SQUARE FOOTAGE COUNTS
HEATED SPACE SF:
FINISHED BASEMENT SF: N/A
FINISHED FLOOR I (MAIN FLOOR) SF: 145q
FINISHED FLOOR 2 (UPPER FLOOR) SF: 1813
TOTAL HEATED SF: 3272
HEATED � UNHEATED SPACE SF:
FINISHED BASEMENT SF:
N/A
FINISHED FLOOR I (MAIN FLOOR) SF:
145q
FINISHED FLOOR 2 (UPPER FLOOR) SF:
1813
GARAGE OPT. 1 (WITHIN BLDG FOOTPRINT):
53q
GARAGE OPT. 2
(w/ 5' x "20' GARAGE EXTENSION (BUMP -OUT):
N/A
GARAGE OPT. 3 (w/ 10' x "20'
(I) ONE CAR GARAGE BAY):
N/A
COVERED BACK PATIO OR DECK SF:
N/A
COVERED FRONT PORCH SF:
45
UPPER FLOOR FRONT DECK SF:
N/A
TOTAL HEATED � UNHEATED SF:
3856 (GARAGE OPT. I�
N/A (GARAGE OPT. 2�
City Of Edmonds
Building Department
ork NEW SFR
ddress 23907 91 ST PL W LOT 3
caner BRACKETT S RESERVE '
pproved Date 7-27-2023
uilding Official /�eU�j�f /��p��e�
ermit Number BLD2023-0686
�� f 'J�.�I.��I
PLAN DETAILS, PLUf�BING, f�ECN. INFO
BLDG TYPE: SINGLE FAMILY
MAX. BLDG DIMENSIONS
(INC. 3RD CAR GARAGE): 36' WIDE x 5q' DEEP
MAX. NUMBER OF BEDROOMS: 5
EXHAUST FANS: 6
GAS PIPING CONNECTIONS: I
NEAT SOURCE: ELECTRIC
NEAT TYPE: NEAT PUMP
NUMBER OF NEAT UNITS: I
FIREPLACE TYPE: ELECTRIC
BATHROOM SINKS: 5
BATHTUB OR COMBO's: 2
CLOTHES WASHERS: I
DISNWASNER: I
FLOOR DRAINS: 0
KITCHEN SINKS: I
LAUNDRY SINKS: 0
SHOWER STALLS (SHOWER PANS): 2
TOILETS: 3 Approved
DFM ctir�s�eurt
WATER HEATER: ELECTRIC South County Fire
Date: 07/13/2023
WATER SERVICE LINES: I
07-13-2023
PLAN REVIEW
NOTES: APPROVED WITH CONDITIONS:
1. A SEPARATE PERMIT SUBMITTAL IS FOR A RESIDENTIAL
SPRINKLER SYSTEM IS REQUIRED. A RECOMMENDED
FLOW -THROUGH DESIGN WILL MEET SPECIFICATIONS AND REDUCE
EQUIPMENT AND CONTINUAING MAINTENANCE REQUIRMENTS.
PROVIDE A MINIMUM COMBINATION WATER SERVICE OF ONE INCH
(1") METER AND ONE AND ONE HALF (1 1/2") SERVICE LINE OR SHOW
THAT THE DOMESTIC AND FIRE PROTECTIONS NEEDS CAN BE MET
WITH A SMALLER SERVICE.
2. 4 INCH ADDRESS CHARACTERS WITH 1/2 INCH STROKE TO BE
INSTALLED ON THE HOUSE VISIBLE FROM THE STREET IN
CONTRASTING COLOR TO THE BACKGROUND. ADDITIONAL ADDRESS
SIGNS MY BE REQUIRED IF NOT VISIBLE FROM THE STREET.
DFM BURY
ARC�IITECTURAL DRAWING INDEX
Al COVER Sl-IFFY
PCN
PLAN Cl-IANGE NOTICE WRITE-UP
A2C
FRONT/SIDE ELEVATIONS
A3C
REAR/SIDE ELEVATIONS
A4
MAIN FLOOR PLAN
A5
UPPER FLOOR PLAN
A6C
FRAMING PLANS: ARCHITECTURAL INFO,
A7
ELECTRICAL PLANS
Aq
ARCHITECTURAL DETAILS
A10
WATER INTRUSION DETAILS
All
WSEC OPTIONS � CALCS
SO1
STRUCTURAL NOTES
S02C
FOUNDATION PLAN
S03C
MAIN FLOOR FRAMING
S03C
MAIN FLOOR FRAMING
SO4C
UPPER FLOOR FRAMING
S05C
ROOF FRAMING
S06
STRUCTURAL DETAILS
S07
STRUCTURAL DETAILS
SOS
STRUCTURAL DETAILS
SOq
STRUCTURAL DETAILS
CITY OF ED�10NDS NOTES
COMMUNITY NAME: BRACKETT's RESERVE
LOT #: 3
ADDRESS: 23g07 gIST PLACE W EDMONDS WA g8026
FIRE SPRINKLES REQ'D? YES
FIRE NOTES:
1) AN APPROVED AUTOMATIC SPRINKLER SYSTEM SHALL BE INSTALLED IN DWELLINGS EXCEEDING
3000 SF OF FIRE AREA. FIRE AREA INCLUDES COVERED PORCHES, DECKS OVER 4' AND DOES NOT
INCLUDE FIRE SEPARATED GARAGES.
NOTE: REFER TO STAMPED 'S' SHEETS PREPARED BY BTL ENGINEERING
FOR ALL STRUCTURAL INFORMATION � ITEMS
DESIGNER � BUILDER
PACIFIC RIDGE >y0�1ES
JASON ATKIN
ARCHITECTURAL PLANS � PERMIT COORDINATOR
jwatkin@pacif icridgehomes.com
17g21 BOTHELL-EVERETT HIGHWAY SUITE 100
BOTHELL WA g8012
PHONE: (425) 438-8444
STRUCTURAL ENGINEER
BTL ENGINEERING
1g011 WOODINVILLE SNOHOMISH ROAD NE SUITE 100
WOODINVILLE WA g8072
PHONE: (425) 814-8448
REVISION REV # DATE
2018 IRC � WSEC UPDATES 0.00 02/15/2023
RECEIVED
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
��
Q
�
�/
Q
O
�
!I li �
�_
U
T' '!
COPYRIGI-17 NOTICE: THIS
PLAN IS OWNED BY PACIFIC
RIDGE HOMES. USE OF THIS
PLAN IS PROHIBITED BY LAW
WITHOUT PAYMENT OF
LICENSE FEE TO PACIFIC
RIDGE HOMES.
PLAN SUMMARY
LOWER LEVEL OR BASEMENT SQ. FT.:
N/A
MAIN LEVEL SO. FT.:
145q
UPPER LEVEL SO. FT.:
1813
TOTAL AREA SQ. PT.:
3272
GARAGE AREA SO. FT.:
53q
HEAT SOURCE:
ELECTRIC
ARCkIITEGTURAL PLANS COORDINATOR:
JWA
ENGINEER:
BTL ENGINEERING
REVISION:
SEE REVISION LOG
GENERAL SCALE U.N.O.
SCALE: Y" = 1'-0"
SPIFFY CONTENTS
COVER
S�IEET
ELEVATION NOTES:
I. CONTRACTOR SHALL VERIFY ALL NOTES, MATERIALS � CONDITIONS PRIOR TO
CONSTRUCTION.
2. CAULK ALL EXTERIOR JOINTS � PENETRATIONS.
3. PROVIDE GALVANIZED OR ANODIZED SHEET METAL FLASHING � COUNTER
FLASHING @ALL ROOF PENETRATIONS, CHIMNEYS � SKYLIGHTS.
4. PROVIDE CONTINUOUS GUTTERS #DOWNSPOUTS @ALL EAVES, TYP.
5. PROVIDE HEADER FLASHING @ALL DOORS, WINDOWS � SHUTTERS PER DETAIL
6. ALL PAPER AND TAPE TO LAP FROM TOP DOWN
7. HOLD ALL SIDING MATERIAL �" OFF ROOF
8. HOLD ALL SIDING MATERIAL 6" OFF FINISHED GRADE
q. SOFFIT ALL FLAT AREAS w/ l�" OVERHANG @ HORIZ. EDGES
10. METAL FLASHING C� ALL HORIZ. TRIM � SIDING BREAKS
11. RUN 2ND LAYER OF TAR PAPER VERT. @ INTERIOR � EXTERIOR CORNERS
UNLESS TAR PAPER IS CONTINUOUS
12. FOUNDATION VENTS TO BE SPACED PER PLAN
13. ALL FOUNDATION VENTS ON STREET SIDE OF HOUSE I.E. FRONT �/OR SIDE �
GABLE END � GARAGE FRESH AIR VENTS TD BE LOUVERED
14. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE INSTALLED AT
7'-6" A.F.F.
15. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH
TOP OF THE GARAGE DOOR TRIM
16. ALL LIGHT BLOCKS ON STONE FACADE TO BE FURRED OUT AN ADDITIONAL l�"
21. GUTTERS TO LAP UNDER DRIP EDGE @EAVES. HOLD �" DRIP EDGE OUT y"
AWAY FROM FASCIA TO ACCEPT GUTTERS TO LAP UNDERNEATH
22. ALL TRIM WORK TO BE APPLIED PRIOR TO SIDING MATERIALS (SIDING TO
BUTT UP TO TRIM WORK)
23. CEILING OF EXTERIOR BACK DECK TO BE FLAT.
NOTE: REFER TO STAMPED 'S' SHEETS PREPARED BY BTL ENGINEERING
FOR ALL STRUCTURAL INFORMATION +� ITEMS
20"
� � � � OF GARAGE 2x6 MATERIAL WITH
� ~ `� � �� BLOCK ��� BEVEL CUT.
� o � FURR OUT 1 y" FOR
STONE VENEER
�12 � ADD-RESS NUMBERS BLOCK
SCALE
NOTE: ALL EXPOSED FASTENERS TO I
� CAULK EXPOSED NAILS WITH ROOFII
SIDING PER PLAN
ROOF TO WALL
FLASHING
ROOFING
ROOFING FELTS
3E SEAI
dG TAR
.ED
E24 LOWER ROOF C� WALL
SCALE: I" = I'-0"
2x SOFFIT —
FRAMING TO
BTM OF BEAM
FIBRE CEMENT
PANEL SOFFIT —
BEAM PER PLAN
,,PER PLAN �,
PT PC
PLAN
Ix OVf
PT FU
2x PT
FRAM I
,, PER PLAN ,,
(2) 2x PT
BTM PLATE
CONC PATH
PER PLAN
SOFFIT
PER SPEC
lx TOP OUT
5/4x TRIM
lx COLLAR
2x
MITERED
BOXED
COLUMN
Ix TRIM
BEVELED
2x SILL w/
DRIP EDGE
Z
a
w
FRONT PORC�I COLUMN
E3� u�/ STONE BASE
SCALE: 3/4" = I'-0"
SIDING
PER ELEV
GALV MTL
FLASHING
2x W.W., PER PLAN
ROUGH SAWN =
PLY SOFFIT
SIDING PER ELEV
SECTION AT OVER�IANG
1 SCALE: 3/4" = I'-0"
SIDING
I'I SIDE OF
HOUSE
FRONT OF � x 2 INSET
CORNER TRIM
HOUSE
E� � TYP CORNER TRIM
SCALE: 1" = 1'-0"
HOUSE CORNER
PROVIDE BLDG PAPER
BEYOND
- SEPARATION BTWN
HOUSE AND ROOF
METAL FLASHING
FRAMING, 6 MIN
ROOFING -CAULK
EYOND
EXPOSED NAILS w/
ROOFING TAR
ROOFING
6n
ROOFING FELT
��
E15 RAKE FLAS�I I NG DETAI L
SCALE: 1" = 1'-0"
SIDING
In SIDE OF HOUSE
2x4 INSET CORNER TRIM
FRONT /BACK
OF HOUSE
E� TYP CORNER TRIM
SCALE: I" = 11-011
# FIR OUT I Y" 10"
{ FIR OUT I Y" � $n FOR STONE VENEER 5 2�� �
FOR S70NE VENEER ��Y HOLE
�n 3%" � HOLE _
%" BEVEL �=N � 5" �
CUT � � /a BEVEL CUT j�' BEVEL
CU7
TYP. BLOCK: NOSEBIB TYP. BLOCK: EXT. TYP. BLOCK: TANKLESS
LIGN7 FIXTURE NW HEATER VENT
TYP. NOSE BIB BLOCK, EXT. LIGHT FIXTURE
BLOCK, � TANKLESS NW NEATER VENT BLOCK
SCALE: I/2"=1'-0"
ROOFING PER SPEC
5/4x KEYSTONE
RAKE FLASH'G
AS REQUIRED
Ix4 TRIM
q0°
I/2" ROOF
5/4x8 BARGE BOARD
SNEATNING
2x6 SPF SUB -BARGE
FLAT OUTRIGGER
@ 24"oc
GABLE END
NARDIE SMOOTH LAP
"'
TRUSS
SIDING w/ 4" REVEAL
GALV MTL FLASHING
2x3 SLOPED SILL
WITH DRIP EDGE
2x6 BAND
SIDING PER PLAN
BARGE,
KEYSTONE, PEDIMENT
DETAIL
SCALE: 3/4" = 1'-0"
� NOTES
•ADHERED CONC. MASONRY
- MIN. 4" ABOVE EARTH
VENEER o/
SIDING PER ELEVATION
-MIN. 2" ABOVE PAVEMENT
•MORTAR SETTING BED o/
FLASHING
-MIN �" ABOVE FOUNDATION.
•SCRATCH COAT o/
2x W.W. PER PLAN
-FLASHING AT BASE OF VENEER
•LATH FASTENERS o/
SHALL EXTEND 1" BELOW THE
•LATH o/
2x SLOPED SILL
SILL PLATE, WHERE APPLICABLE.
• 1 AIR GAP
WITH DRIP EDGE
-LATH FASTENERS: TYPE �
• (2) LAYERS OF WRB o/
'Z' FLASHING
SPACING PER ASTM CI063
•EXTERIOR GRADE SNEATNING
• ADHERED CONC. MASONRY
VENEER o/
• MORTAR SETTING BED o/
WEEP SCREED OR DRIP
• SCRATCH COAT o/
SCREED
•LATH FASTENERS o/
(2) 2x4 PT
FLASHING
• LATH o/
BTM PLATE
1/2" MIN. BEAD SEAL
• 1" AIR GAP
UNDER FLASH'G
• (2) LAYERS OF WRB o/
CONC. PORCH FLATWORK
• EXTERIOR GRADE SHEATHING
POURED AT OR NEAR
,.
HOUSE COMPLETION
WRB LAPPED OVER
WEEP SCREEDS
�
POST FTC. PER PLAN
WOOD SILL � TRIM
COLUMN BASE
DETAIL
SECTION: STONE
VENEER OVER WOOD
FRAMING
_�
SCALE: 3/4" = I'-0"
0
Ix FRIEZE _
PER ELEVATION
m
MAX HT. ALLOW. = 487.90'
RIDGE (EL. 482.88)
Ixl2 FRIEZE BOARD, -
TYP. WHERE SHOWN
5/4x6 BARGE
BOARD w/ Ix4 E21
TRIM, EXTEND 6" A2/
PAST EAVES
UPPER PLATE
� WDW HORS �
TYP. El
WHERE A2'
OCCURS
16" NARDIE —
SMOOTH
MULTI -GROOVE
PANEL
UPPER FLOOR
MAIN PLATE
A.E.G. - 462.90'
EXT WALL Ell
LIGHT WITH A24
SIDING BLOCK
2x10 GARAGE WRAP,
INSTALL PROUD OF -
INSIDE TO CAPTURE
GARAGE DRYWALL
MAIN FLOOR
F.F. = 455.20'
NOSE BIBB w/ E12
SIDING BLOCK A2
SE ELEV. 452.70' — — —
4:12
12
7
ADDRESS E12.
BLOCK A2
8.25" / 7" REVEAL NARDIE
CEDARMILL LAP SIDING,
TYP WHERE SHOWN
TYP. E21
0
W6
A10 TYP 5.5" / 4" REVEAL
34. NARDIE SMOOTH
_ A2A LAP SIDING, TYP
WHERE SHOWN
TYP.
4 El.l WHERE
A W7 2A OCCURS
A10
TYP
WS
7:12 TYP A10
r�� ^� I� �I tm� / � �I �� I I A
�I�E ELE'id-ON �.
BUTT JOINT, TYP.
RECEIVED
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
'�
�
z
o
o
�
��
��
�
�
�
�
o
�
�-
CAPYRIGNT NOTICE: THIS
PLAN IS OWNED BY PACIFIC
RIDGE HOMES. USE OF THIS
PLAN IS PROFIIBITED BY LAW
WITHOUT PAYMENT OF
LICENSE FEE TO PACIFIC
RIDGE HOMES.
PLAN SUMMARY
LOWER LEVEL oR BASEMENT 50. FT:
N/A
MAIN LEVEL 50. FT.:
145q
UPPER LEVEL SQ. FT:
1813
TOTAL AREA 50. FT.:
3272
GARAGE AREA 50. FT.:
539
HEAT SOURCE:
ELECTRIC
ARCHITECTURAL PLANS COORDINATOR:
JWA
ENGINEER:
BTL ENGINEERING
REVISION:
SEE REVISION LOG
GENERAL SCALE U.N.O.
SCALE: Y" = 1'-0"
SHEET CONTENTS:
FRONT $SIDE
ELEVATIONS
'C' ELEVATION
�2�
SCALE: 1/4" = 1'-pll
UPPER PLATE
WDW HDRS
s
UPPER FLOOR
`" MAIN PLATE
WDW HDRS
ATE
)RS
s
)OR
�Q
aTE �
)RS .
�Z
S�
CC
O
I NEAT i � MAIN FLOOR J J ��.
MAIN FLOOR o
m�a � �
NEAT PUMP
f� \ / � � ELECTRICAL q�_6�� \ / %� %�
��� Y � � NOOK UP 21—OII � � 1� Y �i� � mil 3'-0"
SCALE: 1/4" = 1'-0" SCALE: I/4" = I'-0"
��
i� �i �
ELEVATION NOTES:
1. CONTRACTOR SHALL VERIFY ALL NOTES, MATERIALS � CONDITIONS PRIOR TO
CONSTRUCTION.
2. CAULK ALL EXTERIOR JOINTS � PENETRATIONS.
3. PROVIDE GALVANIZED OR ANODIZED SHEET METAL FLASHING � COUNTER
FLASHING @ALL ROOF PENETRATIONS, CHIMNEYS � SKYLIGHTS.
4. PROVIDE CONTINUOUS GUTTERS � DOWNSPOUTS @ALL EAVES, TYP.
5. PROVIDE HEADER FLASHING @ALL DOORS, WINDOWS � SHUTTERS PER DETAIL
6. ALL PAPER AND TAPE TO LAP FROM TOP DOWN
7. HOLD ALL SIDING MATERIAL l�" OFF ROOF
8. HOLD ALL SIDING MATERIAL 6" OFF FINISHED GRADE
q. SOFFIT ALL FLAT AREAS w/ t�" OVERHANG @ NORIZ. EDGES
10. METAL FLASHING @ALL NORIZ. TRIM � SIDING BREAKS
11. RUN 2ND LAYER OF TAR PAPER VERT. @ INTERIOR � EXTERIOR CORNERS
UNLESS TAR PAPER IS CONTINUOUS
12. FOUNDATION VENTS TO BE SPACED PER PLAN
13. ALL FOUNDATION VENTS ON STREET SIDE OF HOUSE I.E. FRONT �/OR SIDE �
GABLE END � GARAGE FRESH AIR VENTS TO BE LOUVERED
14. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE INSTALLED AT
7'-6" A.F.F.
15. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH
TOP OF THE GARAGE DOOR TRIM
16. ALL LIGHT BLOCKS ON STONE FACADE TO BE FURRED OUT AN ADDITIONAL t�"
21. GUTTERS TO LAP UNDER DRIP EDGE @EAVES. HOLD l�" DRIP EDGE OUT Y4'
AWAY FROM FASCIA TO ACCEPT GUTTERS TO LAP UNDERNEATH
22. ALL TRIM WORK TO BE APPLIED PRIOR TO SIDING MATERIALS (SIDING TO
BUTT UP TO TRIM WORK)
23. CEILING OF EXTERIOR BACK DECK TO BE FLAT.
C� �N � � � RECEIVED
SCALE: I/4" = 1'-0"
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
COPYRIGHT NOTICE: THIS
PLAN IS OWNED BY PACIFIC
RIDGE HOMES. USE OF THIS
PLAN IS PROI-IIBITED BY LAW
WITHOUT PAYMENT OF
LICENSE FEE TO PACIFIC
RIDGE HOMES.
PLAN SUMMARY
LOWER LEVEL OR BASEMENT S0. FT.:
N/A
MAIN LEVEL SO. FT.:
145q
UPPER LEVEL SO. FT.:
1813
TOTAL AREA SQ. FT.:
3272
GARAGE AREA S0. FT.:
53q
HEAT SOURCE:
ELECTRIC
ARCkIITECTURAL PLANS COORDINATOR:
JWA
ENGINEER:
BTL ENGINEERING
REVISION:
SEE REVISION LOG
GENERAL SCALE U.N.O.
SCALE: Y" = 1'-0"
SFIEET CONTENTS
REAR � SIDE
ELEVATIONS
'C' ELEVATION
,a,
NOTE: REFER TO STAMPED 'S' SHEETS PREPARED BY BTL ENGINEERING
FOR ALL STRUCTURAL INFORMATION � ITEMS
FLOOR PLAN NOTES
I. CONTRACTOR SHALL VERIFY ALL NOTES, MATERIALS � CONDITIONS PRIOR TO
CONSTRUCTION.
WINDOWS � DOORS:
2. ALL EXTERIOR WINDOW � DOOR HEADERS TO BE INSULATED w/ R-10 INSULATION.
3. WINDOWS � DOORS ARE SHOWN � NOTED AS NOMINAL SIZES.
4. WINDOW HEAD HEIGHT R.O. SHOWN PER ELEVATIONS. EGRESS WINDOW SILL HEIGHT R.O. @
MAX. 42" A.F.F.
5. ALL WOOD IN CONTACT WITH CONC. TO BE PRESSURE TREATED.
6. EXTERIOR WALLS TO BE 2x6 STUDS @ 16" O.C., U.NO.
7. GARAGE DOOR HEADERS @ 84" A.F.F.
8. EXTERIOR SWING DOOR HEADERS @ 83 1/2" A.F.F.
q. INTERIOR SWING DOOR HEADERS @ 83" A.F.F.
10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS OR BE 3" MIN. ON HINGE SIDE.
11. GARAGE -TO -HOUSE DOOR TO BE A SOLID WOOD I%" THICK 20-MINUTE FIRE -RATED DOOR
w/ A SELF CLOSING HARDWARE DEVICE.
12. PER R311.3.1: THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL EXTERIOR DOORS
EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4" BELOW THE TOP OF THE
THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR
13. ALL BI-FOLD � BI-PASS DOORS TO BE CENTERED, U.N.O.
FRAMING:
14. VERIFY FIREPLACE STYLE � LOCATION w/ SUPERVISOR PRIOR TO CONST.
15. FRAMERS TO INSTALL ALL WINDOWS � INTERIOR COLUMNS
I6. TOWEL RING BLK'G @ 57" A.F.F.
17. TOWEL BAR BLK'G @ 48" A.F.F. � BLOCK BOTH BAYS.
I8. TOILET PAPER HOLDER BLK'G @ 22" A.F.F. AND 42" FROM BACK WALL WHERE POSSIBLE
Iq. THERMOSTAT BLK'G @ 60" A.F.F
20. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE INSTALLED AT 7'-6" A.F.F.
21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE
GARAGE DOOR TRIM
22. ADD CONT. BLOCKING FOR STAIR HANDRAIL BRACKETS
23. STAIRS w/ WINDER STEPS WILL ALWAYS NAVE A CONTINUOUS HANDRAIL INSTALLED ON
THE INSIDE OF THE STAIR's RUN
24. LADDER -BLOCK AT EXTERIOR WALLS AS NECESSARY FOR INSULATION INSTALL
VENTILATION:
25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CENTRAL EXHAUST FAN IN
ACCORDANCE WITH M1505.4.1.1.
26. WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY.
27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M1505.4.3(1). EXAMPLE: 70 CFM FOR 2600
SF HOME w/ 4 BEDROOMS, AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE
M1505.4.3(2) TO ACCOUNT FOR NOT -BALANCED, NOT -DISTRIBUTED VENTILATION SYSTEM.
28. WHOLE HOUSE FAN SHALL BE I.0 SONES OR LESS, AND SHALL HAVE AN EFFICACY OF 2.8
CFM /WATT PER WSEC R403.6.1.
2q. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE WINDOWS PER STATE
CODE INTERPRETATION 17-15.
30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE
WHOLE HOUSE FAN.
31. PER IRC M1502.4.5.: WHERE THE DRYER VENT EXHAUST DUCT IS CONCEALED WITHIN THE
BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE
IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED
WITHIN 6FT OF THE EXHAUST DUCT CONNECTION.
LIFE SAFETY:
26. A HEAT ALARM OR NEAT DETECTOR RATED FOR AMBIENT OUTDOOR TEMPERATURES AND
HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE.
27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE
ALARM THAT IS INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY, ROOM OR
OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION
10. SMOKE DETECTORS TD BE IIOV, INTERCONNECTED, w/ BATTERY BACKUP � CENTRALLY
LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE
INSTALLED WHERE THERE IS A CEILING NEIGNT CHANGE GREATER THAN 24
I1. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROM THE
DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER. [R314]
12. IONIZATION SMOKE ALARMS:
� SHALL NOT BE INSTALLED LESS THAN 20 FT HORIZONTALLY FROM A PERMANENTLY
INSTALLED COOKING APPLIANCE.
� IONIZATION SMOKE ALARMS WITH AN ALARM -SILENCING SWITCH SHALL NOT BE INSTALLED
LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE.
24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FT
HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE [R314]
25. GARAGE NOTE: WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2" G W B � 5/8"
TYPE 'X' ON THE CEILING. POLY SEAL RIM, ENTIRE GARAGE TO MEET JURISDICTION
DRAFT STOP REQUIREMENTS
26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH Y" GWB AT THE
WALLS, UNDER -STAIR SURFACES AND SOFFITS.
27. PROVIDE FIREBLOCKING PER PLAN AND @ALL PLUMBING PENETRATIONS.
NOTE: REFER TO STAMPED 'S' SHEETS PREPARED BY BTL ENGINEERING
FOR ALL STRUCTURAL INFORMATION � ITEMS
ELEVATION ,�
2x8 PLATE @
RAISED WALL,
RIPPED TO "6"
%4' SUB -FLOOR
I -JOIST
PER PLAN
BLDG PAPER
BTWN JOIST
EQ. `� EQ.
�i�
I
FRONT DOORIPER PLAN
FRONT PO1�CH SLAB
4'-0"
D9 DOOR THRESHOLD
-�
2x W.W.
TOE KICK
iv @DOOR
(2)2x4's TO BE
REMOVED PRIOR
DOOR � JAMB ��
TO FRONT
STEP/WALK BEING
CAULK BACK OF
POURED
THRESHOLD TO
cO
NERVESTRAL
� ALL SEAMS
END � CONC. ---- i i i i i III"
PLATE 6 STEM FRONT � T.O. RAISED
WALL BEYOND FRONT PORCH PORCH
RAISED SLAB. SLOPE STEM STEM WALL TO
STEM ya PER LIN. WALL � T.O. FRONT PORCH
SECTION WALL � FT. MAX. STEM WALL = 7"
•� FRONT PORC�I EXT. DETAIL
SCALE: 1/2" = 1'-011
CENTER TRIM d LANDING ON
FRONT DOOR /OPERABLE
SIDE OF SLIDER
EQ. EQ.
SGD PER PLAN
OPERABLEI
FIXED
PANEL I
PANEL
LINE OF
NERVESTRAL
__________ __________
I I
2x6 HEARTWOOD CEDAR TRIM,
BEHIND
I I I
EO. ALL SIDES, CAULK/SEAL
� �
EQ. � � � I EQ.
BOTTOM OF
I I
3'x3' LANDING TYP.
SIDING
i �\�., \\�, I I
POUR AGAINST
NERVASTRAL
FRONT PORCH 0 PATIO
3'-6" LANDING TYP.
BACK PATIo�e suouLD ALwAYs
Q.
@BACK PATIO's (?.
BE POURED IN THE DIRECTION
OF THE FIXED SIDE OF THE
S.G.D. WHENEVER POSSIBLE
�
2x6 HEARTWOOD CEDAR
TRIM
DOOR
LANDING PER PLAN. POUR
THRESHOLD
AGAINST NERVESTRAL
2x6 HEARTWOOD CEDAR
--� -
L__�_______ -
TRIM w/ FLASHING @
NERVESTRAL
'�I
� '
HOUSE INTERSECTION,
-LANDING PEP PLAN _ WHERE OCCURS
-# OF STEPS i6D BY ---
�� I LINE OF NERVESTRAL
MUD SILL
SITE CONCI i IONS
i I
CONC. WALL
SLAB ON GRADE
SEE D38 FOR FRONT DOOR
AND FRONT PORCH DETAIL
EXT. LANDING DETAIL C�
SLIDING GLASS DOOR, TYP
SCALE: N.T.S.
WRAP NERVASTRAL
UP JAMB 6"
(2) %a" BEADS OF
CAULK UNDER
NERVESTRAL, (I)
WRAP EDGE � @SIDES OF JAMB
THRESHOLD w/
ADD'L NERVASTRAL NERVASTRAL OR EQ
Dq T�IRES�IOLD DETAIL
SCALE: 1-I/2" = I'-0"
0
I'-3" 16'-0" .1'-3"
n, I
m I I
� 0
�y-------' � S EP UP
�I
fY
al S,EP UP 311
NI
�� AI_OII TYP.
D41 Lul
A2C �; q 3
�� ADD
�I
�I
{- I
18'-0" 6'-3" 2'-3"
DRIVEWAY WIDTH
Did V�WAY/PO�RC� Pl_AN
SCALE: 3/8" = 1'-0"
cn
_1
('n
0
v
F
0
i
24"x36" NEAT
PUMP BASE
5'-2%n
24"x36" NEAT
PUMP BASE
WHEN REQ'D
804 XOX
36'-0"
61_il/II
y
�1AIN FLOOR PLAN: 'A' ELE`✓.
STONE VENEER,
TYP WHERE SHOWN
RECEIVED
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
A �
LL
W
J
w
n
CL�
Q
'�
�
z
�
�
�
�
�
�
�
o
�
�-
COPYRIGHT NOTICE: THIS
PLAN IS OWNED BY PACIFIC
RIDGE HOMES. USE OF THIS
PLAN IS PROHIBITED BY LAW
WITHOUT PAYMENT OF
LICENSE FEE TO PACIFIC
RIDGE HOMES.
PLAN SUMMARY
LowER LEVEL OR &15EMENT SQ. Fr:
N/A
MAIN LEVEL 50. FT.:
1459
UPPER LEVEL S0. Fr.:
1813
TOTAL AREA 50. FT.:
3272
GARAGE AREA SG. FT:
53q
NEAT SOURCE:
ELECTRIC
ARCHITECTURAL PLANS COORDINATOR:
JWA
ENGINEER:
6TL ENGINEERING
REwsION:
SEE REVISION LOG
GENERAL SCALE U.N.O.
SCALE: Y" = 1'-0"
SHEET CONTENTS
MAIN FLOOR PLAN
SCALE: 1/4" = 1'-0"
36'-0"
FLOOR PLAN NOTES
1. CONTRACTOR SHALL VERIFY ALL NOTES, MATERIALS � CONDITIONS PRIOR TO
CONSTRUCTION.
WINDOWS � ODORS:
2. ALL EXTERIOR WINDOW � DOOR HEADERS TO BE INSULATED w/ R-10 INSULATION.
3. WINDOWS � DOORS ARE SHOWN � NOTED AS NOMINAL SIZES.
4. WINDOW HEAD HEIGHT R.O. SHOWN PER ELEVATIONS. EGRESS WINDOW SILL HEIGHT R.O. @
MAX. 42" A.F.F.
5. ALL WOOD IN CONTACT WITH CDNC. TD BE PRESSURE TREATED.
6. EXTERIOR WALLS TO BE 2x6 STUDS @ 16" O.C., U.NO.
7. GARAGE DOOR HEADERS @ 84" A.F.F.
8. EXTERIOR SWING DOOR HEADERS @ 83 1/2" A.F.F.
9. INTERIOR SWING DOOR HEADERS � 83" A.F.F.
10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS OR BE 3" MIN. ON HINGE SIDE.
11. GARAGE -TO -HOUSE DOOR TO BE A SOLID WOOD I%" THICK 20-MINUTE FIRE -RATED DOOR
w/ A SELF CLOSING HARDWARE DEVICE.
12. PER R311.3.1: THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL EXTERIOR DOORS
EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4" BELOW THE TOP OF THE
THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR
13. ALL BI-FOLD � BI-PASS DOORS TO BE CENTERED, U.N.D.
FRAMING:
14. VERIFY FIREPLACE STYLE � LOCATION w/ SUPERVISOR PRIOR TO CONST.
15. FRAMERS TO INSTALL ALL WINDOWS � INTERIOR COLUMNS
16. TOWEL RING BLK'G @ 57" A.F.F.
17. TOWEL BAR BLK'G @ 48" A.F.F. � BLOCK BOTH BAYS.
18. TOILET PAPER HOLDER BLK'G @ 22" A.F.F. AND 42" FROM BACK WALL WHERE POSSIBLE
19. THERMOSTAT BLK'G @ 60" A.F.F
20. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE INSTALLED AT 7'-6" A.F.F.
21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE
GARAGE DOOR TRIM
22. ADD CONT. BLOCKING FOR STAIR HANDRAIL BRACKETS
23. STAIRS w/ WINDER STEPS WILL ALWAYS NAVE A CONTINUOUS HANDRAIL INSTALLED ON
THE INSIDE OF THE STAIR's RUN
24. LADDER -BLOCK AT EXTERIOR WALLS AS NECESSARY FOR INSULATION INSTALL
VENTILATION:
25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CENTRAL EXHAUST FAN IN
ACCORDANCE WITH M1505.4.1.1.
26. WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY.
27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M1505.4.3(1). EXAMPLE: 70 CFM FOR 2600
SF HOME w/ 4 BEDROOMS, AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE
M1505.4.3(2) TO ACCOUNT FOR NOT -BALANCED, NOT -DISTRIBUTED VENTILATION SYSTEM.
28. WHOLE HOUSE FAN SHALL BE I.0 SONES OR LESS, AND SHALL NAVE AN EFFICACY OF 2.8
CFM /WATT PER WSEC R403.6.1.
29. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE WINDOWS PER STATE
CODE INTERPRETATION 17-15.
30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE
WHOLE HOUSE FAN.
31. PER IRC M1502.4.5.: WHERE THE DRYER VENT EXHAUST DUCT IS CONCEALED WITHIN THE
BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE
IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED
WITHIN 6FT OF THE EXHAUST DUCT CONNECTION.
LIFE SAFETY:
26. A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR TEMPERATURES AND
HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE.
27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE
ALARM THAT IS INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY, ROOM OR
OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION
10. SMOKE DETECTORS TO BE IIOV, INTERCONNECTED, w/ BATTERY BACKUP � CENTRALLY
LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE
INSTALLED WHERE THERE IS A CEILING HEIGHT CHANGE GREATER THAN 24
11. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROM THE
DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER. [R314]
12. IONIZATION SMOKE ALARMS:
� SHALL NOT BE INSTALLED LESS THAN 20 FT HORIZONTALLY FROM A PERMANENTLY
INSTALLED COOKING APPLIANCE.
$ IONIZATION SMOKE ALARMS WITH AN ALARM -SILENCING SWITCH SHALL NOT BE INSTALLED
LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE.
24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FT
HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE [R314]
25. GARAGE NOTE: WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2" GWB � 5/8"
TYPE 'X' ON THE CEILING. POLY SEAL RIM, ENTIRE GARAGE TO MEET JURISDICTION
DRAFT STOP REQUIREMENTS
26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH y" GWB AT THE
WALLS, UNDER -STAIR SURFACES AND SOFFITS.
27. PROVIDE FIREBLOCKING PER PLAN AND @ALL PLUMBING PENETRATIONS.
NOTE: REFER TO STAMPED 'S' SHEETS PREPARED BY BTL ENGINEERING
FOR ALL STRUCTURAL INFORMATION � ITEMS
A
16"
OF SOAP
NICHE,
SHOWER
,q
PEX TUBING,
CONTROL
�
SHOWER
PAN
I �
i it
TYP.
SHOWER CONTROLS
16"x24"x6" DEEP
SOAP NICHE
1 ___}� �� I�
- -
I IIII
BUTT NICHE TILE
INTO FIELD TILE,
li II
-I - -11-! I'�I
TOP � SIDES
-
-
SECTION A -A BUTT FIELD
24"
�
�
-
�"
(ZOOMED IN @ NICHES TILE INTO
BOTTOM of
NICHE TILE
(3) LAYERS I"
�
' ',
-
�, t i� ',
POLY -ISO RIGID APPROX. STUD
I � I
INSULATION, EXT. LAYOUT
I I
� � I
�
I I
WALLS ONLY
SHOWER DOOR -
,
i
i
_
�
i ii
ii i i
II
ii i
FIELD TILE
II
I
i
I
�,���� n
'd4
II II
� I i I
SHOWER PAN
II I,
�,
2x6 or 2x4
SECTION A -A
2x8 WALL,
(@ EXTERIOR WALLS
WALL
PER PLAN
BACK
WALL
OF
���� S fii O W � � SOAP
'�Cl
N
C fi`1 �
SHOWER,
TYP.
SCALE: NTS
DOUBLE RIM OR
PROVIDE SPLICE
ADD FLAT
2X4 THROUGH
�4ux6ll
JOIST @ 5' O.C.
srT HRs416z.
ATTACH TO
2x AND TO
STAIR RIM
PER PLAN
�i
SECTION A -A
(@ INTERIOR WALL
�ux�u
0
_� s
j MAKE UP AIR IS REQUIRED '
SECTION THRU
WALL CAP � FOR THE LAUNDRY ROOM AND �
� CLOSET ENCLOSING THE AIR ,
' HANDLER IN ACCORDANCE �
� WITH 2O18 IMC 504.E �
D15 HALF „WALL FRAf�ING � CAP DETAIL
SCALE: I/2 1 0
- PROVIDE MIN. 30"
HEADROOM CLEARANCE.
- TRUSSES MUST BE
INSTALLED @ 24" O.C.
ATTIC ACCESS
SHEATHING ON
OUTSIDE OF
TRUSS MEMBERS
0
5/4 TRIM � � GWB ATTIC
OR SIM. ACCESS LID
03q ATTIC ACCESS DETAIL
SCALE: 1/2 = 1 -0
GROUT �
SEAL, TYP.
� SHOWER GLASS �
FRAME
SLOPED TILE -� ��I
CAP
�/ - 2" DRYWALL
L CERAMIC TILE 12"W S.A.M., --. --.
SURROUND BITUTHENE � a
OR EQUIV. � 3
2x4 STACKED w a
BLOCKING AT o �
SHOWER PAN SHOWER CURB. can �
.� a
(SOAKER TUB AT HALF `-'
SIM.) WALL, FRAME
LIKE HALF -
WALL. � �
SUB FLOOR
TILED SI-TOWER CURS I-4ALF WALL SI �I. ,
SCALE: 3" = I'-0"
s
1
0
�Q
v
�_��
oNON
-�.
_ o N
m � ��
v `* �
o w
v �
v
I1'-2" 7'-�" 17'-Oy"
4'-8" ,, 4'-0" ,, 2'-6" 71-�" 4'-�" ,, 8'-0" 4'-qll
TR
® �
z
a
I `�
O
2468
4040 PIC,
8046 XOX
OBS., S.G.
(EGRESS)
�� �
�
i
W.I.C.
i
2x4 SOFFIT it
3 .d-
�
6'2x7'3
�N
-�
��
72"x36" FREE-
N
'� I
�I
13
�
i
STANDING TUB PER
I
LP
SPEC. PROVIDE TEMP.
I
�
I
�
i
LIMITING VALVE PER
I
�
I
I
2018 UPC 40q.4
I
`"
I
I
I
"S
' ' �
BDRM 1
BATH 1
CPT
; ; � �°
;
16'7x23'8
10'gx17'3 2868
; ; N �
;
II
I
I
1=
I
v
I
i
I
�„
�
I
I
�
2
I
I
�
I
I
I
I
�
�
4'-1n
�I
^ I
I^
I N
I
I
SD
�
�
`'i
W.I.C.
i 3
�'
41-6" �
'�
B5
3 �x �°
;
6'2x7'3
;
I
5
SH ER
I
I
J
2x8 WALL w/ w
SOAP NICE �
A
L_____--_____J
W/S(I)
�,
TB Q
xb WALL
rrr�
��
I�w s�1) _D _
I U (VENT
I
I
RooF)
I '� SD
3 UTIL. �
� � 61 SF
V i I
BDRM 2
10'6x13'S I A Ss I_ II
4 6
0
o U
(Y �
0
O U
(V �
(LANDING) -
__ 6 � DN
LINE OF GARAGE -� � INSTALL WHOLE 17R,16T
WALL BELOW F. . . � "OUSE FAN ii IT 2T 3T o
TRANSFER GRIL 42 HALF WALL �,
0
_I N ABOVE D00 qT �
15'
oN
w
°° � o � BDRM 3
o � �r w
- '" 10'Sx13'8
cn
SD
-'
2668
SD
��
0
LOFT
12'2x18'6
2040 CSMNT 2040 PIC 2040 PIC
w/ GRID w/ GRID w/ GRID
PER ELEV. PER ELEV. PER ELEV.
0
_�
����� LINE OF
WALL
BELOW
cn
o
0
SD
I
I
I
I
I
I
I
I
I
I
I�
i c -�
13 N
I 3
I
I
Ig40 PIC
Ig40 PIC
(S.G) w/
(S.G) w/
GRID
GRID
PER ELEV.
PER ELEV
OPEN TO 5T -
4'-6" BELOW � 6T
38"H HALF WALL. _ �
� GWB or OPEN
a RAIL PER SPEC � 8r �
� o
4'-6n � (LANDING)
� _
I6T 15T 14T 13T 12T IIT IOT 9T
2x6 WA L
SD/CO
TR (2) 2x6 WALLS
® TP
'� II ��
0 0 60" VANITY 1,-6 3T x6/
"S HALL BATH sH R
CPT
2668 5'6x11'10 TB
W/S(1)
---------------
2668
4'-6° Hs
cPT O SD 4/0
BI-FOLD
Q
OPEN TO � � BDRM 4
aELow � � 10'1x11'11
3036 PIC
w/ GRID o
PER ELEV. m
2646 PIC 2646 CSMNT
w/ GRID w/ GRID
PER ELEV. PER ELEV.
i n,:=i
2'-0" 2'-0" 2'-0° 2'-0" 2'-0" 2'-0" i'-q" I'-q" 2'-0" I'-6° 3'-0° I'-6° 2'-q" 2'-6" 2'-6" 2'-q°
61I'-0" 6' 8'- II 6'-0" 11'- II
36'-0"
UPPER FLJJR PLAN: 'A' ELE`/.
0
_�
N
0
v
0
v
LL
W
'�
�
z
o
o
�
��
�
�
�
�
o
�
�-
CAPYRIG"T NOTICE: THIS
PLAN IS OWNED BY PACIFIC
RIDGE "OMES. USE OF T"IS
PLAN IS PROFIIBITED BY LAW
� WIT"OUT PAYMENT OF
o LICENSE FEE TO PACIFIC
�`+ RIDGE HOMES.
- PLAN SUMMARY
�_
LOWER LEVEL oR BASEMENT 50. FT:
_� N/A
� MAIN LEVEL 50. FT.:
145q
UPPER LEVEL SQ. FT:
1813
TOTAL AREA SO. FT.:
3272
GARAGE AREA 50. FT.:
539
HEAT SOURCE:
ELECTRIC
ARCHITECTURAL PLANS COORDINATOR:
JWA
ENGINEER:
BTL ENGINEERING
REwsIaN:
SEE REVISION LOG
GENERAL SCALE U.N.O.
SCALE: �" = 1'-0"
SHEET CONTENTS:
UPPER FLOOR PLAN
RECEIVED �,��,„�:
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SCALE: 1/4" = 1'-pll
FOUNDATION NOTES:
I, CONTRACTOR TO VERIFY ALL NOTES, MATERIALS, CONDITIONS
PRIOR TO CONSTRUCTION.
2. STEP FOUNDATION PER SITE CONDITIONS.
3. ALL WOOD IN CONTACT w/ CONCRETE TO BE PRESSURE
TREATED.
4. PROVIDE CONSTRUCTION /CONTROL JOINT IN SLABS PER
ARCHITECTURAL DRAWINGS. JOINTS SHALL BE APPROX. SQUARE
� 400 SQUARE FEET OR LESS.
5. CONTRACTOR TO VERIFY LOCATION OF KNOCK -OUTS FOR
STORM, SEWER, WATER � DRAINAGE.
6. IS" MIN. CRAWL SPACE CLEARANCE TO BOY. OF FLOOR JOISTS.
12" MINIMUM CRAWL SPACE CLEARANCE TO BOY. OF BEAMS.
7. COVER BOTTOM OF CRAWL SPACE w/ 6 MIL BLACK VAPOR
BARRIER. LAP JOINTS 12".
8. EXCAVATOR TO INSTALL (2) 2x4's FOR BLOCKING BETWEEN
DOWNSPOUT LOCATION � FNDN STEM WALL BEFORE INSTALLING
DOWNSPOUT TD TIGHTLINE CONNECTOR PIPE TO ENSURE PROPER
CLEARANCE FOR FLATWORK, SIDING MATERIAL, STONE VENEER.
ATTIC NOTES:
I, VENTED BIRD BLOCKING AND GABLE END VENTING IS NOT
ALLOWED WHEN THE EXTERIOR WALL IS 5FT OR LESS
FROM THE PROPERTY LINE OR WHEN THE SAVE OR
OVERHANG IS LESS THAN 5FT FROM THE PROPERTY LINE.
SYMBOLS � LEGEND
O
SMOKE DETECTOR
BIRD BLOCK OR
�
SMOKE/CO2 DETECTOR
' ' ' ' ' '
SOFFIT VENT LOCATION
AF50 ROOF "JACK" AIR VENT.
�H
NEAT DETECTOR/ALARM
�" lo"
(Lu/ CUT-OUT SIZE � SHAPE)
— � —
5' 5"
BATH FAN � BATH FAN VENT
FLOOR ABOVE
OF
(w/ CUT-OUT SIZE � SHAPE)
FLDOR BELOW
�"wNF �"
O
WHOLE HOUSE FAN VENT
SAFETY
�'P,��'
(Lu/ CUT-OUT SIZE � SHAPE)
FURNACE VENT
�
ROOF SAFETY ANCHOR
(w/ CUT-OUT SIZE � SHAPE
ANCHOR
BUCK -OUT WHEN
WALL LENGTH IS
LONGER THAN 6'
�1 P.T. 2x2
NAILER FOR
GARAGE WRAP (CORNER
� SIDING CONDITION)
ATTACHMENT
1 PLAN VIEW AREA OF
RA I S � D ST � � RAISED STEM
WALL
WALL: S DING NAILER
0�2 SCALE: 3/4" = I'-0"
�I P.T. 2x2 NAILER
FOR GARAGE WRAP
� SIDING ATTACHMENT
ELEVATION PLAN VIEW
C�ARAC�E WRAP � S I D I NG NA I L�R's
,� � TALL GARAC�� P ERS
SCALE: 3/4" = I'-0"
ROOF VENTILATION A ELEV MAIN ROOF
STANDARD TRUSS /SCISSOR TRUSS ROOF FRAMING ASSEMBLY
ATTIC AREA: 1,971.0
VENTILATION REQUIRED: 946 SQ IN (1sf PER 300sf OF ATTIC AREA)
PROVIDE 50-60% OF REQ'D VENTILATION WITHIN 3' OF EAVES & 40-50%WITHIN 3' OF RIDGE
LOWER VENTING REQUIRED: 50-60% OF VENTILATION REQUIRED
BIRD BLOCKING: 3.70 SQ IN NET FREE AREA PER LF
((3)-2" DIA SCREENED HOLES, EA TRUSS BAY)
LF OF BIRD BLK'G PROVIDED: 47 ACROSS FRONT AND REAR EAVES ONLY
(PROVIDE SOLID 2x BLOCKING ALONG EAVES WHERE WALLS OR OVERHANGS ARE PARALLEL
TO AND WITHIN 5FT OR LESS OF PROPERTY LINES)
BIRD BLOCK VENT'G PROVIDED: 173.8 SQ IN
AF-50 ATTIC ROOF JACK 50 SQ IN NET FREE AREA EA.
VENTILATION REQ'D /AREA PER VENT: 5.99
# ROOF JACKS PROVIDED: 7
ROOF JACK VENT'G PROVIDED: 350 SQ IN
TOTAL LOWER VENTILATION PROVIDED: 523.8 SQ IN (51.2%)
UPPER VENTING REQUIRED: 40-50% OF VENTILATION REQUIRED
AF-50 ATTIC ROOF JACK 50 SQ IN NET FREE AREA EA.
VENTILATION REQ'D /AREA PER VENT: 7.57
# ROOF JACKS PROVIDED: 10
TOTAL UPPER VENTILATION PROVIDED: 500.0 SQ IN (48.8%)
TOTAL VENTILATION AREA PROVIDED: 1023.8 SQ IN
---� ----
OR00� FRAMING DIAGRAM �
RELEVANT INFO.: 'A' ELEV.
SCALE: 3/16" = 1'-0"
ROOF VENTILATION A ELEV LOWER ROOF
STANDARD TRUSS /SCISSOR TRUSS ROOF FRAMING ASSEMBLY
ATTIC AREA: 80.0
VENTILATION REQUIRED: 38 SQ IN (1sf PER 300sf OF ATTIC AREA)
PROVIDE 50-60% OF REQ'D VENTILATION WITHIN 3' OF EAVES & 40-50%WITHIN 3' OF RIDGE
LOWER VENTING REQUIRED: 50-60% OF VENTILATION REQUIRED
BIRD BLOCKING: 3.70 SQ IN NET FREE AREA PER LF
((3)-2" DIA SCREENED HOLES, EA TRUSS BAY)
LF OF BIRD BLK'G PROVIDED: 24 ACROSS FRONT AND REAR EAVES ONLY
(PROVIDE SOLID 2x BLOCKING ALONG EAVES WHERE WALLS OR OVERHANGS ARE PARALLEL
TO AND WITHIN 5FT OR LESS OF PROPERTY LINES)
BIRD BLOCK VENT'G PROVIDED: 88.7 SQ IN
TOTAL LOWER VENTILATION PROVIDED: 88.7 SQ IN (64.0%)
UPPER VENTING REQUIRED: 40-50% OF VENTILATION REQUIRED
AF-50 ATTIC ROOF JACK 50 SQ IN NET FREE AREA EA.
VENTILATION REQ'D /AREA PER VENT: 0.31
# ROOF JACKS PROVIDED: 1
TOTAL UPPER VENTILATION PROVIDED: 50.0 SQ IN (36.0%)
TOTAL VENTILATION AREA PROVIDED: 138.7 SQ IN
I -- � _�
I T I �ii I
II � � �� I I
� i �— -- —�� I'
�'
I'�� �_
N � I
�� ` {�
�/ f I I
I r �
� ]� I I ���; ��; �� FORCED AIR UNIT IN MECI� LINE OF DRAFT
II �' �� �' '' CLOSET ON UPPER FLDOR. STOPPING AT
'-II�" ��' THE FLR TRUSS LAYOUT FLOOR TRUSSES:
q'-10' ','� ,' ���� �� �� FLOOR TRUSS
SHOULD LEAVE 21 D.C.
�_ - _
�- - � MIN. CLR ALL SIDES MFR TO DESIGN
BELOW FORCED AIR UNIT TRUSSES FOR
BLOCKING
I
,� I
12'-I1 8n '� II T — - - - - - -
j H
- � II '
r �-�--
t air I � I I
�� J�I� � II ---- —.—
i II
I I �
II
II
II
II
II
i i 5'"q"
I
� -_ o
-------------
24" FLOOR �,�
� TRUSSES OVER
I� � �ARAGE ONLY WIT�I
X � R-38 BELOW m- - _- -- v
Q� -
UC WO
D T RK
I
II -
T
I
II
I � � �
I
III
I '
I
' �� — — � .�
-_---- I — - — --- ® �
� - �.; I � -
i •�< 7'i<
PITCH PITCH i =
APPLY FSK PAPER AT
EXT. RIM OF GARAGE
U���� �L. ��A�1 N� D A��A�1
\\// I I
�� �VA � ��.� � � �Y .
SCALE: 3/16" = 1'-0"
CRAWL SPACE VENTILATION
CRAWL SPACE AREA:
1,459.0
SQ FT
VENTILATION REQUIRED:
700.3
SQ IN (1sf PER 300sf OF CRAWL AREA)
FOUNDATION VENTS USED:
7" x 14"
NET FREE AREA PER VENT:
73.5
SQ IN (25% REDUCT w/ 1/4" MESH)
VENT AREA REQ'D /AREA PER VENT:
9.53
# OF VENTS REQUIRED:
10
7" x 14"
VENTS PROVIDED:
11
7" x 14" FOUNDATION VENTS
VENT AREA PROVIDED:
808.5
SQ IN
CRAWL SPACE
18" MINIMUM CRAWL SPACE.
12" MINIMUM UNDER BEAMS.
6 MIL BLACK POLYETHYLENE GROUND
COVER. LAP JOINTS 12"
R-30 INSULATION BTWN. JOISTS.
a � CRAWL SPACE
a. VENT, TYP
D/S
w
�7
<.1
L]�
J.
L7
'�
�
z
�
��
��
�
�
�
�
O
�
�-
COPYRIGHT NOTICE THIS
PLAN IS OWNED BY PACIFIC
RIDGE HOMES. USE OF THIS
PLAN IS PROHIBITED BY LAW
WITHOUT PAYMENT OF
LICENSE FEE TO PACIFIC
RIDGE HOMES.
5'-2�'
PLAN SUMMARY
®
LOWER LEVEL DR BASEMENT SQ. PT.:
'' 9
N/A
MAIN LEVEL SO. FT.:
145q
UPPER LEVEL SO. FT.:
1813
4" THICK CONCRETE SLAB �
TOTAL AREA sa. �.:
SLOPE TO DOOR q" PER FT.
J
3272
GARAGE AREA 50. FT.:
53q
�
NEAT SOURCE:
6 �
ELECTRIC
ARCHITECTURAL PLANS COORDINATOR:
D42 AREA OF RAISED
A6 STEM WALL. SEE
TWA
°'�'"�'
SHEET S02 FOR DIM's
� sTRucTURAL.
BTL ENGINEERING
REVISION:
AREA OF RAISED
SEE REVISION LOG
GENERAL SCALE U.N.O.
RAISED PIER, BOTH
Dis
�
D37 SIDES. SEE SHEET D/s
SCALE: �" = 1'-0"
A6 S02 FOR DIM's � D/S
SPIFFY CONTENTS:
STRUCTURAL.
DOWNSPOUTS,
VENTING, PLUMBING
DRAIN(S):
'C' ELEVATION
I I \ N � L= . � � I \ I I N C� D I \ C� � I \ I I � RECEIVED BEET MIMBER:
I I I jj� Jun 08 2023
T � � � � � ' ° � T � � DE E'LOPMENDT SOERDV CES
SCALE: 3/16" = 1'-0" DEPARTMENT
ELECTRICAL PLAN NOTES:
I. SMOKE DETECTORS 70 BE lIOV, INTERCONNECTED, W/ BATTERY
BACKUP � CENTRALLY LOCATED IN EACH HABITABLE ROOM.
ADDITIONAL SMOKE DETECTORS SHALL BE INSTALLED WHERE
THERE IS A CEILING HEIGHT CHANGE GREATER THAN 24" (IRC R314)
2. A COMBINATION SMOKE /CARBON MONOXIDE DETECTOR SHALL BE
PLACED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE
IMMEDIATE VICINITY OF THE BEDROOMS. (IRC R315)
3. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT
HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT
CONTAINS TUB OR SHOWER. (IRC R314)
4. IONIZATION SMOKE ALARMS:
� SHALL NOT BE INSTALLED LESS THAN 20 FT HORIZONTALLY FROM
A PERMANENTLY INSTALLED COOKING APPLIANCE.
� IONIZA710N SMOKE ALARMS W17H AN ALARM -SILENCING SWITCH
SHALL NOT BE INSTALLED LESS THAN 10 FT HORIZONTALLY FROM
A PERMANENTLY INSTALLED COOKING APPLIANCE.
� PHOTO ELECTRIC SMOKE ALARMS: SHALL N07 BE INSTALLED LESS
THAN 6 FT HORIZONTALLY FROM A PERMANENTLY
INSTALLED COOKING APPLIANCE (IRC R314)
5. PER IRC M1507.3.2.: A LABEL SHALL BE AFFIXED TO 7NE
WHOLE HOUSE FAN CONTROL THAT READS "WHOLE HOUSE FAN
VENTILATION (SEE OPERATING INSTRUCTIONS)"
6. CEILING CAN LIGHTS OF A HABITABLE ROOM ARE TO BE INSTALLED
4' OR LESS FROM AN ADJACENT WALL SO A CEILING FAN RATED
JUNCTION BOX IS NOT NECESSARY
ELECTRICAL SYMBOL LEGEND
SYMBOL
DESCRIPTION
�j SINGLE POLE SWITCH
�j� MULTI -WAY SWITCH
IIOV DUPLEX CONVENIENCE OUTLET
,{-� IIOV DUPLEX CONV. OUTLET W/ GFI
Y-V (GROUND FAULT INTERRUPTER)
220v or 240v OUTLET (PER EQUIP. SPEC)
WP IIOV DUPLEX OUTLET (WEATHER PROOF)
�j+ (I) IIOV OUTLET E (2) USB OUTLETS
BLANK PLATE
NWT IIOV DUPLEX OUTLET FOR NOT WATER TANK
HALF NOT IIOV DUPLEX CONVENIENCE OUTLET
Q� GARAGE DOOR OPENER IIOV DUPLEX OUTLET
pW IIOV DISHWASHER OUTLET
220V CLOTHES DRYER OUTLET
CLOTHES WASHER OUTLET
��
220v OUTLET FOR ELECTRIC CAR CHARGER
RECESSED CEILING MOUNTED LIGHT FIXTURE
CEILING MOUNTED LIGHT FIXTURE
P
PENDANT LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE (INT. � EXT.)
��
FLUORESCENT FIXTURE
�
PORCELAIN KEYLESS LIGHT FIXTURE
IIOV SMOKE DETECTOR, W/ BATTERY BACKUP
COMBO CO2 E SMOKE DETECTOR
NEAT DETECTOR /ALARM
RECESSED CEILING MOUNTED FAN, V.T.O.
WHOLE HOUSE FAN
WHOLE HOUSE FAN TIMER CONTROL
WALL MOUNTED HEATING E COOLING UNIT (MINI -SPLIT)
�0
MINI-SPIJT
�'�'
N�^T�
ELECTRICAL CEILING HEATER
STACKED DATA (TOP)
JACK t SMURF TUBE
ACCESS BLANK PLATE
THERMOSTAT
TDP
CAMEO RGb w/ (2) CAT5E
6
9
�'_
D/P
COMBO JACK WITH (2) CAT5E
1
TELEPHONE JACK
t
SMURF TUBE OR EQUIVALENT
HOME AUTOMATION CONTROLS
A/C WP
PRE -A/C OR NEAT PUMP
DOOR BELL
FLAT PANEL PRE -WIRE
sP SURROUND SOUND SPEAKER
6
• CENTER ALL LIGHT FIXTURES ON
VANITY SINK(S).
• LIGHT FIXTURES OVER VANITIES
TO BE 82"-86" F.F.
• REFER TO CABINET LAYOUTS FOR
9
KITCHEN APPLIANCE AND VANITY
CENTERLINE LOCATIONS.
UPPE2 F_GCR ELECTRIC=1
(ALL ELE`✓'s SIM. )
SCALE: I/4" = I'-0"
HWT TO BE
INSTALLED
IN THE 3rd
CAR
GARAGE OR
GARAGE
BUMP -OUT
WHEN THAT
OPT. IS
SELECTED.
w�
IlA
FOR
UTILITY
LAYOUT,
SEE W5/IIA
MAIN FLOCK ELECTRIC^L PLAN
(ALL ELE`/'s SIr.Z
SCALE: y" = I'-0"
POWER "WHIP" +86"
HOOD +78"
RANGE +18"
RECEIVED
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
LL
W
J
'�
�
z
o
o
�
��
��
�
�
�
�
o
�
�-
CAPYRIGHT NOTICE: THIS
PLAN IS OWNED BY PACIFIC
RIDGE HOMES. USE OF THIS
PLAN IS PROHIBITED BY LAW
WITHOUT PAYMENT OF
LICENSE FEE TO PACIFIC
RIDGE HOMES.
PLAN SUMMARY
LOWER LEVEL oR BASEMENT 50. FT:
N/A
MAIN LEVEL 50. FT.:
145q
UPPER LEVEL SQ. FT:
1813
TOTAL AREA SO. FT.:
3272
GARAGE AREA 50. FT.:
53q
HEAT SOURCE:
ELECTRIC
ARCHITECTURAL PLANS COORDINATOR:
JWA
ENGINEER:
BTL ENGINEERING
REVISION:
SEE REVISION LOG
GENERAL SCALE U.N.O.
SCALE: �" = 1'-0"
SHEET CONTENTS:
ELECTRICAL PLANS
- COMPOSITION ROOFING -TRUSSES ARE STAMPED BY
15# FELT o/ 7/16" OSB fANUFACTURERS ENGINEER
SHEATHING o/ ROOF LICENSED IN WASNINGTON
TRUSSES PER PLAN STATE INSTALLED AND
BRACED PER MANUFACTURERS
SPECIFICATIONS LOADS: 25#
L.L.+ 15# D.L. = 40# TOTAL
R49 INSULATION
IN ATTIC - R38
@ VAULTS
y" Gwa
CLASS II VAPOR RETARDER
PRIMER PAINT w/ A
f101STURE PERf1 RATING OF
1.0 OR LESS (EX. RODDA
PAINT VAPOR SHIELD).
(2)2x6 TOP PLATES STD/BTR SPF
1/2" GWB
2x6 STUDS @ 16" O.C. TYP.
R21 BATT INSULATION.
(2) LAYERS #7 ATCO FELT
BARRIER OR HOUSE WRAP
7/16 O.S.B.
2x6 BOTTOM PLATE
NAIL PER SW SCH
3/4" TAG FLOORING NAIL AND GLUE —
2x10 @RIM AND BLOCKING w/ R-21
FOIL FACED INSULATION, CLASS I OR II
FLOOR JOISTS PER PLAN
�" GWB �
CLASS II VAPOR
RETARDER PRIMER
PAINT w/ A MOISTURE
PERM RATING OF 1.0 OR
LESS (EX. RODDA PAINT
VAPOR SHIELD).
(2)2x6 TOP PLATES —
STD/BTR SPF
1/2" GWB
2x6 STUDS @ 16" O.C. TYP
R21 BATT INSULATION.
(2) LAYERS #7 ATCO FELT BARRIER
OR HOUSE WRAP
7/16 O.S.B.
2x6 BOTTOM PLATE NAIL PER SW SCN
RIM PER PLAN
ANCHOR BOLTS �
SPACING PER SW
SCHEDULE
R38 INSULATION '
2x6 PRESSURE TREATED MUD SILL
6 f11L BLACK POLYETHYLENE GROUND
COVER. LAP JOINTS 12"
INSULATION
BAFFEL EXTEND
12" ABOVE
INSULATION WITH
I I/2" AIR SPACE
%x6
FASCIA -
(TYP)
5" CONT.
GUTTER
6" MIN.
TO SOI L
11111111l�i
��i I II
TYP. �XTERIDR WALL SECTION
SCALE: N.T.S.
POWER C
PLASMA
OUTLET
SMURF rt
(1)LAYEI<
(1) 3/4"
PLYWOOL
BLACK t^
BLANK F
w/ COAX
SMURF �f
110V DUP
OUTLET
POWER C
I��
I I I I
�I� II
II � II
�\�
I
I I
II
II
I
�
I I I I
II II
II II
OPEN it0 ABOVE i i
"
ii ii
II II
i i
ii
II
PLASMA
OUTLET
SMURF 7
�
(1) 3/4"
�
�
PLYWOOL
�
��
BLACK t^
,� 2x10
\ �
BACKING
�
(TYP)
�
�
— — — � %4" PLYWOOD
a
\ �
�
4
��
�
U
�
�
BLANK F
° � I
° �
Q
Q
�
�
Lu/ COAX
° � � '
Z
� �
SMURF �1
° \ �
�
HAND RAIL @ \ �
° �
°°
34"-3a" � \
110V DUP
� �
�
ABOVE NOSE �
OUTLET
�
OF TREAD
CONNECT °
�
STRINGERS
TO RIM w/
LS50 TYP
AT STAIRS
ADJACENT EXTERIOR
WALLS, CONNECT
STRINGER TO 2x6
STUDS w/ 6" SDS
SCREWS AT EACH
STUD WHERE
POSSIBLE, TYP
ACCESSIBLE SPACE
UNDER STAIRS TO
BE 2" f11N Gwa
II II
II II
� V
° �
it ° �
� 10" MIN. LINE OF CURB WHEN
� TREAD RAILING OPT. CHOSEN.
II ° � EPTH
° a � CURB TD BE 5" FROM
I I � � � � NOSING
° _w
° � N
II � �
II �
II
OTE: ALL STAIR CO STRUCTIO , ° �
CLEARANCES AND HANDRAIL
LOCATIONS PER IRC SECTION 312. °
I I
I I I I I I I I 1x4 STRI ING BACK I I
TYP STAIR S ACT I ON
SCALE: N.T.S.
OTE: C ECK Lu/ CO TRACTOR
OR UP BADE OPTIONS
70u
MIN.
F R�PLAC� �L�V. � J I ON� UNIT IN UPPER RIGI-IT CORNER
SCALE: N.T.S.
70u
�, MIN. �,
� R�PLAC� ELEV. _ � L� UNIT IN UPPER RIG�IT CORNER
v L�
SCALE: N.T.S.
7%" MAX RISER HEIGHT.
lo" MIN TREAD DEPTH PROVIDE DRAFT STOPPING (GWB
LU/ I Ya" NosE (r" f11N., oR DENS GLASS AT BACK FACE
MAX RADIUS �6') )
�� OF FIREPLACE CAVITY
� STAIRS:
(3) 2x12" STAIR
0 1 JACKS EA.
° 2x4 THRUST
BLOCK
-�
������J
2x4 FRAMING
ABOVE FIREPLACE
11%II
. MIN.
F REPLACE PLAN V EW
SCALE: N.T.S.
45%" R.O.
51_qu
ELECTRIC FIREPLACE INSERT
"SIMPLIFIRE SF-ALL48-BK"
2x4 FIREPLACE
WALL FRAMING
a
� 2x6 R.O.,
o ALL SIDES
w
LXu o
� 2x4 FIREPLACE
`y WALL FRAMING
A -A FRAf� N� SECT ON
SCALE: N.T.S.
-�/ � 2x4 FIREPLACE
—WALL FRAMING
� 0
3
2x6 R.O.,
� �� ALL SIDES
0
Lll
w O
� 2x4 FIREPLACE
`y �—WALL FRAMING
A -A FRAM NG SECT ON
SCALE: N.T.S.
RECEIVED
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
LL
W
J
w
y
Q
'�
�
z
o
o
�
��
��
�
�
�
�
o
�
�-
CAPYRIGNT NOTICE: THIS
PLAN IS OWNED BY PACIFIC
RIDGE HOMES. USE OF THIS
PLAN IS PROFIIBITED BY LAW
WITHOUT PAYMENT OF
LICENSE FEE TO PACIFIC
RIDGE HOMES.
PLAN SUMMARY
LOWER LEVEL oR BASEMENT Sa. FT:
N/A
MAIN LEVEL 50. FT.:
145q
UPPER LEVEL SQ. FT:
1813
TOTAL AREA 50. FT.:
3272
GARAGE AREA 50. FT.:
53q
HEAT SOURCE:
ELECTRIC
ARCHITECTURAL PLANS COORDINATOR:
JWA
ENGINEER:
BTL ENGINEERING
REwsION:
SEE REVISION LOG
GENERAL SCALE U.N.O.
SCALE: Y" = 1'-0"
SHEET CONTENTS
ARCNI7ECTURAL
DETAILS
��I
SLIDING GLASS DOOR
SELF ADHESIVE
PER PLAN
MEMBRANE PAN
SLIDING GLASS DOOR
FLASHING
NAIL FLANGE
NAIL ON FLEXIBLE
GALV 'Z' FLASHING
FLASHING
2" MIN FROM TOP OF
FLOOR JOIST
LEDGER TO LAG SCREW
PER PLAN
5/4x4 CEDAR DECKING
PER PLAN
�
2x PT JOIST PER PLAN
a � � rI rI i i � HANGER PER PLAN
RIM JOIST � In �1;�� \ PT LEDGER PER PLAN
BUILDING PAPER � SHEATHING PER PLAN
INSTALLED BEHIND
LEDGER AND PAN SIDING PER PLAN
FLASHING. LAP � LEDGER INSTALLED BEFORE SIDING
OVER HOUSE WRAP
° w/ BUILDING PAPER BEHIND IT Lu/ 8"
EXPOSED ON ALL 4 SIDES
I� DECK LEDGER DETAIL
FRONT
CORNER
OF HOUSE
AT GARAGE
N.T.S.
5'-6" TO NOSE BIB
3'-6" TO
C.L. OF
PRONTO
BEND '' ELECTRICAL
METER MAIN
PRONTO BEND
INSTALLED ON
EXT. OF HOUSE
HOSE
�� BIBB
INSTALL
GROUNDING
PROD 12" FROM
PRONTO BEND
FORTIFLASH o/ FLASHING
q" MOISTOP
AND MOISTOP. TURN
FORTIFLASH 1" ONTO PANEL,
ALL SIDES � CORNERS.
FLASHING
2x2 TRIM @PERIMETER
TYP.
OPENING FOR ELEC.
60 MIN. BLDG
METER BOX, FIREPLACE
PAPER BEHIND
DIRECT VENT, RANGE VENT,
METER MAIN
DRYER VENT, ETC.
� SEE DETAIL W10 FOR MOISTOP INSTALL
INSTRUCTIONS
ELECTRIC �1ETER �
NOSE BIB
LOCATION
(ND
GAS
�1ETER)
SCALE: N.T.S.
FRONT
CORNER
OF HOUSE
AT GARAGE
� 10'-6" TO NOSE BIB
S'-6" TO C.L.
OF PRONTO BEND
3'-6" 3'-0°
EDGE TO EDGE TO
EDGE I. I. EDG>�r ELECTRICAL
METER MAIN
PRONTO BEND
INSTALLED ON
EXT. OF HOUSE
NOSE
GAS �� BIBB
METER INSTALL
GROUNDING
ROD 12" FROM —_
PRONTO BEND
FORTIFLASH o/ FLASHING
q" MOISTOP
AND MOISTOP. TURN
FORTIFLASH 1" ONTO PANEL,
ALL SIDES � CORNERS.
FLASHING
2x2 TRIM C� PERIMETER
TYP.
OPENING FOR ELEC.
60 MIN. BLDG
METER BOX, FIREPLACE
PAPER BEHIND
DIRECT VENT, RANGE VENT,
METER MAIN
DRYER VENT, ETC.
� SEE DETAIL W10 FOR MOISTOP INSTALL INSTRUCTIONS
ELECTRIC � GAS
DETER, NOSE
BIB CLEARANCES
�
LOCATIONS
3�
WATEI
BARR
JOINT
I NSTA
IN MO
CONTF
SIDING
PLAN
SIDING BUTT JOINT FLASH I NG
SCALE: N.T.S.
30# FELT PAPER
STARTER STRIP
FLASHING _�
GUTTER PER
PLAN ROOF TRUSS
FASCIA PER PLAN
,,� FLASH I NG DETAIL C� EAVE
SCALE: N.T.S.
OVERLAP MIN. IS"
I � BLDG. PAPER TYP.
SIDING PER PLAN
2x2 PRIMED TRIM
W� SIDING /INSIDE CORNER
SCALE: N.T.S.
%a" x 3" LAG SCE
POSITIVELY ATTACE
TO WALL STUDS. l
SCREW TO PENETRt
STUDS I" MIN., TYF
I/3 AND 2/3 HT
HWT. ATTACH Lu/ I
x 16 GA. STRAP
2/3 HT OF HW"
I/3 HT OF NWT
P
LINE OF
NERVESTRAL
BEHIND
BOTTOM OF
SIDING
rvrrnln rvilnl ill im Innnn
EXTERIOR DOOR FLASH I NG
SCALE: N.T.S.
CENTER TRIM E LANDING ON
FRONT DOOR /OPERABLE
SIDE OF SLIDER
EQ. EQ.
SGD PER PLAN
OPERABLE
PANEL I
---------- ----------
I I
EQ. � � � j EQ.
I
I
I
I
FRONT PORCH 0 PATIO
Q.
3'-6" LANDING TYP.
@BACK PATIO's
Q.
FIXED
PANEL
2x6 HEARTWOOD CEDAR TRIM,
EQ. ALL SIDES, CAULK/SEAL
3'x3' LANDING TYP.
POUR AGAINST
NERVASTRAL I
BACK PATIO's SHOULD ALWAYS
BE POURED IN THE DIRECTION
OF THE FIXED SIDE OF THE
S.G.D. WHENEVER POSSIBLE
�j� 2x6 HEARTWOOD CEDAR TRIM
DOOR
LANDING PER PLAN. POUR
THRESHOLD
AGAINST NERVESTRAL
2x6 HEARTWOOD CEDAR
- �-"--
L__�_______ �I
TRIM w/ FLASHING @
NERVESTRAL
� I
HOUSE INTERSECTION,
-LANDING PER PLAN _
��!
WHERE OCCURS
('MiN. S'x3', TYP.) �/�
---
-�" OF Sl'Er'S i 5D by �—j � I
LINE OF NERVESTRAL
MUD SILL
SfiE CONDITIONS a\ � ;
CONC. WALL
SLAB ON GRADE°
SILL A
PER S
GYP. E
EXT W
PLAN
INSULT
(WHER
� � � � — � —III—III— — — — SEE D38 FOR FRONT DOOR
�� ��� AND FRONT PORCH DETAIL
EXT. LANDING DETAIL �
SLIDING GLASS DOOR, TYP
�`� SCALE: N.T.S.
/`rA� ALIT
WINDOW FRAME
3/8" BEAD CAULK
SEALANT
TRIM PER ELEVATION
(WHERE APPLICABLE)
MOISTOP (SEE DETAIL
WIO FOR INSTALL)
FORTIFLASH ON ALL
SIDES OF WINDOW
SIDING PER PLAN
BLDG. PAPER
PENETRATION
\ HEADER /
\ /
\ /
ROUGH
OPENING
JAMB \
/SILL \
iiiiiiiiiiia 611
SILL .��
FLASHING
BUILDING PAPER TO EXTEND ! I I I I I
MIN. 12" BEYOND ALL EDGES STEP I
OF THE PENETRATION .ATTACH SILL STRIP OF q" WIDE MOISTOP (OR EO.) FLASHING MATERIAL
WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL.
• EXTEND THIS STRIP AT LEAST 12" BEYOND THE EDGE OF THE ROUGH
OPENING
PENETRATION PROTECTION •ATTACH FLASHING MATERIAL WITH CORROSION -RESISTANT STAPLES.
SCALE: N.T.S.
NOTE: SEAL ALL
EXPOSED FASTENERS
SHEATHING PER PLAN
INSULATION BLDG PAPER
PER PLAN APPROVED FLASHING
(O.lq x 10" ROLL)
SIDING PER PLAN 1-I/2'I GAP
BTWN ROOF AND SIDING
ROOF SHINGLES
30# FELT TO EXTEND UP
WALL 12" MIN.
7/16" PLYWD. SHEATHING
WINDOW SILL � WOOD FRAf�E WALL
SCALE: N.T.S.
NOTE: USE 3 STRAPS ON 75 GALLON AND GREATER SIZES
WATER NEATER (NWT) STRAPS
—" ROOF SHEATHING PER PLAN
ROOF TRUSS
ROOF TO WALL FLASH I NG
SCALE: N.T.S.
GYP. BD.
TRIMMER
KING STU
SEALANT
MOI STOP
DETAIL W
FOR INST.
WINDOW F
SEALANT
TRIM PEF
(WHERE AI I ��,.,,���/
,� WINDOW JA>�fB DETAIL
LAP SIDING, U.NO. (HOLD 1-I/2"
OFF ADJOINING ROOF)
METAL FLASHING
(MAY BE STEPPED)
BUILDING PAPER ON
SHEATHING (SIDING CUT
AWAY FOR CLARITY)
METAL RAIN DIVERTER (THE
PURPOSE IS TO SHED THE
WATER OFF THE ROOF AND
KEEP IT AWAY FROM THE
VERTICAL WALL BENEATH).
FASCIA PER PLAN w/
GUTTER
SCALE: N.T.S.
� ,
i r
r
. .
i r �
,� ,' �
i r �
r �
I \ \ >v;>
//�;`_
$NOTE SEAL ALL
EXPOSED FASTENERS
DETAIL C� ROOF/WALL IN7ERSEC710N
CONT. BEAD OF
����—
►���
►;.;.;
►.❖.�
►���
� �
� �
•
►�OOi
►i�i�i
►000
!Q�!�!
��::•:
• -
;.;.;.
BUILDING
BUILDING PAPER
PAPER TYP.
TYP
STEP 2
• ATTACH JAMB STRIPS OF q" WIDE MOISTOP (OR EO.).
FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB
OF THE ROUGH OPENING.
• START JAMB STRIPS 2" BELOW SILL STRIP AND EXTEND 6"
ABOVE LOWER EDGE OF HEADER.
\\ NAIL FILANGEJ LBNDERNSI LASTRIP // \\ //
STEP 3 STEP 4
• APPLY A 3/8" CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME •APPLY THE NEXT COURSE OF BUILDING PAPER (BUTTING TO THE
NAILING FLANGE AT ALL SIDES OF THE WINDOW FRAME OPENING) OVER THE JAMB FLASHING MATERIAL.
• PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE •APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE
INSTALLED JAMB AND SILL � JAMB MOISTOP (OR EQ.) FLASHING MATERIAL. BOARD FASHION UP THE WALL, LAPPING COURSES A MINIMUM OF
• NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS 1/2 PAPER WIDTH.
• STARTING FROM THE BASE OF THE WALL, APPLY BUILDING PAPER UNDER
THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND
ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING.
• ADD FORTIFLASN STICK FLASHING @BOTH SIDES OF WINDOW
• APPLY SLOPED 28 GA,. 2" BACK, PREFINISHED METAL FLASHING TO OPENING.
• APPLY 6" FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW. EXTEND PAST
JAMB FLASHING 2"
,,� STANDARD FLASH I NG >�IATER I AL APPLICATION AT OPENINGS
SCALE: N.T.S.
INSULATION
(WHERE OCCURS)
WD. FRAME WALL
PER PLAN
7/16" PLYWD. SHEATHING
BLDG. PAPER
SIDING PER PLAN
FORTIFLASH ON ALL
SIDES OF WINDOW
ROOF SHINGLES
PER SPEC.
30# ROOF FELT
7/16" OSB ROOF
SHEATHING
INSULATIO
(WHERE 0
WD. FRAM
PER PLAN
R-10 INSU
BEHIND NI
ALL HDR'�
GYP. BD.
HEADER F
(SEE E
W I NDOt^
7/16" PLYWD. SHEATHING
6" FORTIFLASH 0/ FLASHING
SIDING PER PLAN
BUILDING PAPER
MOISTOP (SEE DETAIL WI10
FOR INSTALL)
MIN. 1/4" GAP BTWN SIDING
AND FLASHING
FLASHING TURN DC
1/4" AT EACH END
TRIM PER ELEVATI
(WHERE APPLICABL
SEALANT
WINDOW FRAME
� WINDOW HEAD DETAIL
SCALE: N.T.S.
STUDS @ 16"oc (NO POSTS/
POINT LOADS ABOVE VENTS)
SIDING PER PLAN
� EQ. �, EQ• ,�� BOTTOM SILL PLATE �
3/4" TAG SUBFLOOR
FLASHING
7-1/2"x15-1/2" CEDAR RIM
VENTS Lu/ GALV SCREEN -
PROVIDE LOUVERED VENTS
@ FRONT ELEVATIONS �
RIM PER PLAN '
P.T. MUD SILL '
CONCRETE FOUNDATION
��DO NOT INSTALL VENTS) CLOSER THAN 3' TO GAS METER��
��BUILDING PAPER SHOULD BE INSTALLED OVER FLASHING��
NOTE: PER WSEC R402.2.7: WHEN FOUNDATION VENTS ARE NOT PLACED SO THAT THE TOP
OF THE VENT IS BELOW THE LOWER SURFACE OF THE FLOOR INSULATION, A PERMANENTLY
ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30° FROM HORIZONTAL, TO
DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION.
FOUNDATION VENT
LL
W
J
'�
�
z
o
o
�
��
��
�
�
�
�
o
�
�-
COPYRIGHT NOTICE: THIS
PLAN IS OWNED BY PACIFIC
RIDGE HOMES. USE OF THIS
PLAN IS PROHIBITED BY LAW
WITHOUT PAYMENT OF
LICENSE FEE TO PACIFIC
RIDGE HOMES.
PLAN SUMMARY
LOWER LEVEL oR BASEMENT 50. FT:
N/A
MAIN LEVEL 50. FT.:
145q
UPPER LEVEL SQ. FT:
1813
TOTAL AREA 50. FT.:
3272
GARAGE AREA 50. FT.:
53q
NEAT SOURCE:
ELECTRIC
ARCHITECTURAL PLANS COORDINATOR:
JWA
ENGINEER:
BTL ENGINEERING
REwsION:
SEE REVISION LOG
GENERAL SCALE U.N.O.
SCALE: Y" = 1'-0"
SHEET CONTENTS:
WATER
INTRUSION
DETAILS
�1C
SCALE: N.T.S.
SCALE: N.T.S.
SCALE: N.T.S.
SCALE: N.T.S.
RECEIVED
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Project Information
PLAN NAME: POPLAR A 2018
PLAN SERIES: GLACIER
JURISDICTION: CITY OF EDMONDS
Contact Information
JASON ATKIN
ARCHITECTURAL PLANS COORDINATOR
PACIFIC RIDGE HOMES
ANALYSIS SET UP
Messages /Results "
Review required for custom entries: -Doors
UA Reduction = 19.58, Proposed UA is better than baseline by 5°/n
UA-reduction meets selected Option 1.3
Whole House Mechanical Ventilation Airflow Rate: 160 CFM with Run Time Percent of 50%, Balanced, Distributed
Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ.
What code compliance pathway are you using?
Prescri live Path Com liance with O lion 1 referred
Project Building Type?
New Construction
Occupancy Type?
R3 Sin le famil homes and du lexes
Code Version?
WSEC 2018
Classification:
Medium Dwelling Unit -- 3272 sq. ft.
Baseline Description:
Code Baseline -Baseline and proposed window areas are equal.
About Your Selection:
Up to 15 sf exempt window and 24 sf exempt door allowable
RESULTS -Comparison of Baseline and Proposed Design
Component Performance, R occupancies
Doors U =
Overhead Glazing U =
Vertical Glazing U =
FIatlVaulted Ceilings U =
Wall (above grade) U =
Floors over Crawlspace U =
Slab on Grade F =
Below Grade Wall U =
Below Grade Slab F =
Baseline
U Area UA
0.300
20
6.0
0.500
0
0.0
0.300
355
106.4
0.027
1, 971
53.2
0.056
2, 710
151.8
0.029
1,459
42.3
0.540
0
0.0
0.042
0
0.0
0.570
0
0.0
Proposed Design
U Area UA
0.300
20
6.0
0
0.0
0.277
355
98.1
0.027
1, 971
53.2
0.054
2,710
146.3
0.025
1,459
36.5
0
0.0
0
0.0
0
0.0
Baseline UA Total 359.7 Proposed UA Total 340.1
Required Credits 6.0 Proposed Credits 6.0 from Tables 406.2 and 406.3
UA Percent Reduction 5.4°/n
UA Reduction 19.6
If the Proposed UA <_ the Target UA, and the Proposed Credits from Table 406 are >_ those required in Section R406, then the home meets the WSEC.
Table R406.2 Fuel Normalization Credits
Fuel Normalization Total Credits
stem No. Full Descri lion Select S stem T e Credits 406.2 Ener Credits 406.3 406.2 & 406.3
For an initial heating system using a heat pump that meets federal standards for the
equipment listed in Table C403.3.2(1)C or C403.3.2(2) OR Air to water heat pump units that
are configured to provide both heating and cooling and are rated in accordance with AHRI
2 550/590. Heat pump with electric resistance or fossil -fuel supplemental heat requires Heat Pump, air-to-air or air to water 1.0 5.0 6.0
compliance with WSEC 403.1.2 "Heat Pump Supplementary Heat". Packaged Terminal Heat
Pumps (PTAC-HP) requires an HSPF tested value (See SBC Interpretation dated December
2020 ).
Ta le R406.3 Energy Credits
Energy
�tio No. Cate or Sel ns Credits Brief Descri lion of Selected O tions�
1 Efficient Building Envelope Option 1 . 0.5 U 0.28 Windows / R-38 floors or R-10 Fully insulated slab. Or 5%
reduction in UA
2
Air Leakage Control and Efficient Ventilation
Not Selected
0.0
3
High Effciency HVAC
Option 3-
1.5
Heat Pump: Air Source with min HSPF of 11
4
High Efficiency HVAC Distribution System
Option 4.
1.0
Ducts/distribution system in conditioned space per R403.3.7
5.1
Efficient Water Heating
Not a ected
0.0
5.2-5.
Efficient Water Heating
Option 5.
2.0
NEEA Tier 3 heat pump water heater
6
Renewable Electric Energy
kWh
Not Selected
0.0
7
Appliance Package
Not Selected
0
-
Energy Credits
5.0
T,4C�L �;�IIi,;�
FU Nc�RMA Z,4T1?=/N �=:REC:�IT.S
�_:r�riit
_
�
g y� :em
Qesoriptian of Primary eating Source
1 CI
1 .I_I
■
2
For an initial h sting systeR using a heat pump
that meets f eral standar s for the equipment
listed in Tebl G403.3.2(1 C or C403.3.�? I;� i
ar
Air bo wale heat pump nits that are configured to
provide b� th heating a d cooling and are rated in
acaarda a with AHFi: 550fS9D
�
T���E �as.�
ENERGY CREQGTS
C7 PTION
DE SC R I PTI O FJ
All Other
�:�n�ul� ���-2
'I EFFIt_ IEN BUILDING NL`EL<=rF E �:=!F�TIONS ■
Curly o e option fro Items � .1 through 1.� may be selected in this category.
�: rice with th conductive UA targets is demonstrated using Section Fi402.1.4, Total UA alternative, wrhere
[1-(Rro osed LI arget UA]I� � the required 96UA reduction
1.3
Pr scrip Ive carnpliance is laced on Table R4t72.1.1 with the following
0_S
IVfA
R dlfic flans:
,lertic I f�ene;tration l.J = fJ.28
Floor -�I8
:
Sla on tirade R-1U perimeter and under entire slab
Be gnade slab R-10 perimeter any+ under entire slab
:
ar
ompliance based on Section Fi�O?.1.�: Reduce the Total canductir•e �tJ,4
S%.
THERMAL ENVELOPE DETAILS -Proposed Design
Conditioned Floor Area, Proposed Desi n 3,272 sq. ft
Classification Medium Dwelling Unit
Notes
Exterior Doors
Plan
Com orient
Door
Width
Hei ht
ID
Descri lion
Ref.
U
Qt.
Feet
�"°h
Feet
�"`''
Area
UA
Exem t
Code Baseline, U=0.30
-
0.30
1
2
s
6
s
18
5.3
FRONT
Fiber lass with 10°/ lazin
Custom
0.30
1
3
°
6
e
20
6.0
0
3
°
6
a
0
0.0
0
6
8
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
0
0.0
Sum of Area and UA (excluding exempt door) 20 6.0
Exterior Doors Area Weighted U 0.300
Overhead Glazing
Plan
ID
Component
Descri lion
Ref.
Glazing
U
Qt.
Width
Hei ht
Area
UA
Feet
�"`h
Feet
�"`h
Sum of Area and UA 0.0 0
Overhead Glazing Area Weighted U
Vertical Glazing Schedule Rows to Show
17
Plan
Component
Glazing
Width
Hei ht
Feet
finch
Feet
Inch
ID
Descri lion
Ref.
U
Qt.
Area
UA
Exem t
-
-
-
1
LIVING
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
2
2
°
2
°
8.0
2.24
2
LIVING
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
1
8
°
4
s
36.0
10.08
3
SGD
U=0.25 O lions 1b, 1.4
Table406.2
0.25
1
6
°
6
10
41.0
10.25
4
NOOK
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
1
6
°
4
s
27.0
7.56
5
NOOK
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
1
4
°
2
°
8.0
2.24
6
BDRM 5
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
2
2
°
2
°
8.0
2.24
7
BDRM 5
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
2
2
s
4
s
22.5
6.30
8
BDRM 1
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
2
2
°
4
°
16.0
4.48
9
BDRM 1
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
1
8
°
4
s
36.0
10.08
10
BATH 1
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
1
4
°
4
°
16.0
4.48
11
BATH 1
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
1
2
°
4
°
8.0
2.24
12
BDRM 2
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
1
4
°
4
°
16.0
4.48
13
BDRM 3
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
1
4
°
4
°
16.0
4.48
14
LOFT
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
3
2
s
4
s
33.8
9.45
15
LOFT
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
2
3
°
4
°
24.0
6.72
16
BDRM 4
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
2
2
s
4
s
22.5
6.30
17
STAIR
U=0.28 O lions 1a, 1.3, 1.7
Table 406.2
0.28
2
4
°
2
°
16.0
4.48
Sum of Area and UA 354.8 98.1
Vertical Glazing Area Weighted U 0.277
Vertical Glazing and Doors Area Weighted U 0.278
FIatlVaulted Ceilings
Plan
ID
Component
Descri lion
Ref.
Attic
U
Area
UA
R49 blown Attic STD baffled Code Baseline, O lion 1.1-1.4
10-7
0.027
1 ,971
53.2
Sum of Area and UA 1,971 53.2
4.2
,/AC equipment and associated duct systems} iRstallaliian shall comply
1 i I
P.;.
the rtequirements of Section Ft4B.S_3.7.
;
Locating system components in conditioned cra'rsrl spateti is not pem7itted
i
;
under this option.
Electric resistance heat and ductless heat pumps are not permitted under
this option_
direct combustion heating equipment with AFUE less than �3g9+6 is not
permitted underthisaptian.
Ta qualify to claim this credit, the building permit drawings shall specify the
option being ;,elected and shall speciFy the heating equipment type and
;
shall show the location of the heating and cooling equipment and all the
;
ductwork.
5. EFFICIENT 1NATER HEATII�aG OPTICtr�1S ■
C)nly one option from Items S.� through S.B may be selected in this category. Item 5.1 maybe combined with any
S.S
ter heating system shall include one of the fallov.'ing=
� CI
- _
ectric heat pump water heater meeting the standards for Tier I I I of
EE,4's advanced water heating specification
■
or
:
■
For Fx-� C+ccupancy, electric heat pump water heaters}, meeting the
sta:rxlards for Tier III of NEEA's advanced water heating specification, shill
supply domestic host water to all units_ if one water heater is serving more
:
than one dwelling unit, all hot water stipply and recirculation piping shall be
insulated with R-8 minimum pipe insulation..
:
To qualify to claim this credit, the building permit drawings shall specify the
opkion being selected and shall specify the water heater equipment type
and the minimum equipment. efficiency_
3. HIG�HI FICIENC11r HVAC EQUIPMENT CIPTIONS ■
■
_ n r ne option from Items 3.1 through 3_t3 may be selected in this category.
3_S' ir-source_ centrally ducted Meat pump with rninim�unl HSPF of 11_CI. 1 =� r,,� RECEIVED
To qualify to claim thus credit, the building permit drawings shall speciF�r the � Jun 08 2023
option b€°Trig selected and shall specify the heating equipment type and the � CITY OFEDMONDS
■ DEVELOPMENT SERVICES
minimums equipment efficiency. : DEPARTMENT
Sum of Area and UA 2,710
146
Floor over crawl or exterior
Plan
ID
Component
Descri lion
Ref.
Floor
U
Area
UA
R38 vented Joist 16oc
10-3
0.025
1,459
36
Sum of Area and UA 1,459
36
Slab on Grade (less than 2 feet below rode)
Plan
ID
Component
Descri lion
Ref.
Slab
F
Slab Perim
FP
Sum of Perimeter and FP 0
0
Below Grade Walls and Slabs
Plan
ID
Component
Description
Ref.
Wall
U
Wall
Area
Wall
UA
Slab
F
Slab Perim
Slab
UA
Sum of Area, Length and UA 0 0.0 0
0
Ventilation Requirements
Number of Bedrooms
Run -Time Percent in Each 4-Hour Segment
Is the system Balanced?
Is the system Distributed?
Ventilation Code Section
Whole House Mechanical Ventilation Airflow Rate
5
50%
Balanced Verify system meets definition of'Balanced Whole -House Ventilation'
Distributed Verify system meets definition of'Distributed Whole -House Ventilation'
IRC, Chapter 15
160 CFM
HVAC Thermal Distribution System
Download RS-33 (2018) htt ://www.ener .wsu.edu/Documents/Duct%20Testin %20Standards%2
Is this a hydronic heating system? No
Location of Ducts Conditioned S ace
Location of Air Handler Conditioned S ace
Is Duct Testing Required? No
Option 4.2: A maximum of 10 feet of return ducts and 5 feet of supply ducts are allowed to be located outside of the building thermal envelope, if insulated and sealed per R403.3.7.
Links to Download Forms, Checklists and Other Resources
Link
Compliance Certificate Compliance Certificate Instructions
Insulation Certificate for Residential New Construction Insulation Certificate
Duct Testing Affadavits
Existing Construction Affidavit, Existing
New Construction Affidavit, New
Prescriptive Checklist for 2018 WSEC Prescriptive Checklist
Alterations (Remodel) Worksheet Worksheet
Show Heatin S stem Sizin ?Show
Heatin S stem Sizin -Proposed Desi n Try Out BetterBuiltNW's HVAC Sizing Tool: https://betterbuiltnw.com/resources/hvac-sizing-tool
Nearest Weather Station
Indoor Design Temperature
Outdoor Design Temperature
Design Temperature Difference (vT)
Conditioned Floor Area, Proposed Design
Conditioned Volume
Leave blank to use default of 8.5 ft. ceiling height
HVAC System Type
Location of HVAC Distribution System
Sum of UA, including exempt door and window
Envelope Heat Load
Sum of UA X �T
Air Leakage Heat Load
((Volume X 0-6) X nT) X -018))
Building Design Heat Load
Air Leakage+ Envelope Heat Loss
Building and Duct Heat Load
For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1
For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output
Building and Duct Heat Loss X 1.25 for heat pumps
Building and Duct Heat Loss X 1.40 for all other systems
Edmonds
70 F
24 F
46 F
3,272 ft2
27,812 ft3
Heat Pum
Conditioned Space
345
15,891 Btu /Hour
13,817 Btu /Hour
29,708 Btu /Hour
29,708 Btu /Hour
37,136 Btu /Hour
TABLE M1505.4.3(I )
2018 WSEC WHOLE HOUSE f1ECNANICAL VENTILATION AIRFLOW RATE VENTILATION NOTES AND STANDARDS:
(VENTILATION RATES IN TABLE ARE MINIMUM OUTDOOR AIRFLOW I. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CENTRAL
RATES f1EASURED IN CFM) EXHAUST FAN IN ACCORDANCE WITH MI505.4.1.1.
POPLAR 2. WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY.
MOUSE NAME: 3. WHOLE HOUSE FAN CFM RATE BASED ON TABLE MI505.4.3(I).
EXAMPLE: 70 CFM FOR 4 BDRM 2600 SF HOME, AND THEN INCREASE
BY FACTOR OF 1.5 PER TABLE M1505.4.3(2) TO ACCOUNT FOR
WHOLE MOUSE FAN CFM CALL: SO CFrI x 1.5 = 120 CF�1's NOT -BALANCED, NOT -DISTRIBUTED VENTILATION SYSTEM.
4. WHOLE HOUSE FAN SHALL BE 1.0 SONES OR LESS, AND SHALL NAVE
TABLE fIR1�45.#,31[1l AN EFFICACY OF 2.8 CFM /WATT PER WSEC R403.6.1.
YPHOLE-HOUSE AAECHANICAL ►IEhITIt.ATIOC� AIRFLOYP RATE 5. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE
NVmhcrof 9e�4orns
Dwadliny tlnil
Efaar Aro-s ¢qulirra teat)
b• 1
2
3
4
IS or ��
Alrhuw Ire slur
< saa
3a
3D
35
as
54
501 • 1.000
34
35
db
50
55
1.OU1 • i,sO6
�
+fD
Aa
`aa
GO
1,501 - 2,040
35
45
SU
er3
85
2.04y - 2.3a4
40
54
55
65
70
45
55
5a
70
3,Ii70t - a.t;a�
50
Ga
GS
75
�
- �
56
Bs
70
Sltl
4,OOi -4,SOA
60
70
75
85
9D
+i,501 •5.alan
G5
75
a0
sa
95
WINpOWS PER STATE CODE INTERPRETATION 17-15.
6. LOCAL EXHAUST FAN RATES ARE AS FOLLOWS: KITCHEN - 100 CFM
INTERMITTENT. BATNROOMS/TOILET RMS - 50 CFM INTERMITTENT.
7. HEATING DUCTS ARE NOT ALLOWED TO DISPLACE REQUIRED
INSULATION WITHIN THE EXTERIOR WALLS, FLOORS AND CEILINGS.
8. PER IRC M1502.4.5.: WHERE THE DRYER VENT EXHAUST DUCT IS
CONCEALED WITHIN THE BUILDING CONSTRUCTION, THE EQUIVALENT
LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A
PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE
LOCATED WITHIN 6FT OF THE EXHAUST DUCT CONNECTION.
9. THE BUILDING'S THERMAL ENVELOPE SHALL BE CONSTRUCTED TO
LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE REQ'MNTS OF
SECTIONS R402.4.1-R402.4.4. AIR LEAKAGE RATES TO NOT EXCEED
5.0 A.C.N. (R402.4.1.2)
10. ENERGY CODE COMPLIANCE CHART WITHIN 3' OF ELECTRICAL PANEL.
II. A PROGRAMMABLE THERMOSTAT IS REQUIRED.
11111irp5.b.S.1 Y4nlflatlnn qual#ty adjuskrnent� The rninlnfum wyple hopsa +renlllation rate fwrn Section 12. A MINIMUM OF 75% OF ALL LIGHTING MUST BE NIGH EFFICIENCY
9b[3b_4.3 S1►ali be adlust� by ore sysicm caeiticrenl rn i9C[e rutlSr}S.4_;ilY) basctl an IRo system type
n01 i'rleering the dei"rrriiion of a balenaad+4r�o1e a7ouse ver!5iaatrtln system arroror not m eating the
¢efirHrian of 2 dfglri�[#ed wflole h01y5r' ire+,lrlaffort Syslern,
TABLE M7505.�.3�3}
SYSTEf41 CQEFFICfENT {�,Y„s,,,}
$y5tem Type
❑i5trlbtt#gd
Nat �Istrlbuted
Balancers
7.{}
1.25
Nat balanced
1.75
1.5
VENTILATION SCHEDULE
YYYI
NUTONE OR EQUIV I.0 SONES CFM RATE PER CALL.
2
NUTONE OR EQUIV 1.5 SONES
NOTES:
+USE 100 CFM MIN. FAN AT KITCHEN
+ USE 50 CFM MIN. FANS AT ALL OTHER LOCATIONS EXC. WNF
� ALL FANS VENT TO OUTSIDE (V.T.O.)
'�
�
z
�
o
�
��
�
�
�
�
O
�
COPYRIGHT NOTICE: THIS
PLAN IS OWNED BY PACIFIC
RIDGE HOMES. USE OF THIS
PLAN IS PROHIBITED BY LAW
WITHOUT PAYMENT OF
LICENSE FEE TO PACIFIC
RIDGE HOMES.
PLAN SUMMARY
LOWER LEVEL OR BASEMENT SQ. FT.:
N/A
MAIN LEVEL SO. FT.:
145q
UPPER LEVEL SO. FT.:
1813
TOTAL AREA SQ. FT.:
3272
GARAGE AREA S0. FT.:
53q
HEAT SOURCE:
ELECTRIC
ARCrIITECTURAL PLANS COORDINATOR:
JWA
ENGINEER:
BTL ENGINEERING
REVISION:
SEE REVISION LOG
GENERAL SCALE U.N.O.
SCALE: Y" = 1'-0"
SHEET CONTENTS:
2018 WSEC
CREDIT OPTIONS
� CALC's
GENERAL STRUCTURAL NOTES:
CRITERIA:
1.1 All Materials workmanshi desi n and construction shall conform to the drawin s s ecifications and the International Buildin Code IBC 2018 Edition
p, 9 9 p 9 ( ),
1.2 Design Loading Criteria
The Design Loading of the Structure is as follows:
Live Loads (in accordance with IBC Table 1607.1)
Occupancy or Use
Uniform Live
Load
Concentrated
Live Load
Notes
Floor, Residential
40-psf
-
Balconies &Decks
60-psf
-
1.5 x Occupancy Load
Uninhabitable attic, with storage
20-psf
-
Concurrent with Snow Loads
Unihabitable attic, without storage
10-psf
-
Non -concurrent with Snow Loads
Handrails and Guards
-
200-Ibs
Any point, any direction (ASCE 7-16, Section 4.5.1)
Wind Design Data
ASCE 7-16, Chapter 28: Simplified Envelope Procedure
Basic Design Wind Speed (3-sec gust), V
100 mph
Risk Catagory
II
Wind Exposure
B
Internal Pressure Coefficient
N/A
Exterior Components and Cladding
25-psf
Topographical Factor, KZt
1.00
Snow Loads
(ASCE 7-16, Chapter 7)
Ground Snow Load, Pg
25-psf
Flat Roof Snow Load, Pf = 0.7 Ce Ct IS P9
25-psf
Snow Exposure Factor, Ce
1.0
* Snow Load Importance Factor, IS
1.0
* Thermal Factor, Ct
1.2
Do not adjust for slope or drift unless noted on the Drawings.
See Drawings for Additional Loading Criteria.
Seismic Design Data
ASCE 7-16, Section 12.8: Equivalent Lateral Force Procedure
Risk Catagory
II
Seismic Importance Factor, le
1.0
Mapped Spect. Accel., Short Period, Ss
Mapped Spect. Accel., 1-Sec, S�
1.500
0.500
Site Class
D
Spectral Response Coeff., Short Period, SDs
Spectral Response Coeff., 1-Sec, Spy
1.200
0.600
Seismic Design Catagory
D
Basic Seismic -Force -Resistance System
Ply. Shear Walls
Response Modification Factor, R
6.5
Seismic Response Coefficient, Cs
0.18
Design Base Shear, V
0.18 x Weight
1.3 Structural Drawings shall be used in conjunction with all other project documents for bidding and construction. Contractor shall verify dimensions and
conditions for compatibility and shall notify architect of all discrepancies prior to construction.
1.4 Contractor shall provide Temporary Bracing for the structure and structural components until all final connections have been completed in accordance with
the drawings.
1.5 Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work.
1.6 Contractor -initiated changes shall be submitted in writing to the Architect and Structural Engineer for approval prior to fabrication or construction. Changes
shown on shop drawings only will not satisfy this requirement.
1.7 Drawings indicate general and typical details of construction. Where conditions are not specifically indicated but are of similar character to details shown,
similar details of construction shall be used, subject to review and approval by the Architect and the Structural Engineer.
1.8 All structural systems composed of components to be field erected shall be supervised by the Supplier during manufacturing, delivery, handling, storage and
erection in accordance with instructions prepared by the Supplier.
GEOTECHNICAL:
2.1 Allowable Soil Pressure, Lateral Earth Pressure, and Soil Profile Type are assumed and therefore must be verified. If soils are found to be other than
assumed notif the Structural En ineer for ossible foundation redesi n. Footin s shall bear on firm undisturbed earth at least 18" below adjacent finished
Y 9 p 9 9 1
grade. Unless otherwise noted, footings shall be centered below columns or walls above. Backfill behind all retaining walls with free draining, granular fill and
provide for subsurface drainage.
Geotechnical Properties
Soil Site Class
D
Allowable Soil Bearing Pressure
2000-psf
Active Lateral Earth Pressure (Unrestrained)
35-pcf
Seismic Lateral Earth Pressure
6H-psf
Passive Lateral Earth Pressure
300-pcf
Base Friction Coefficient
0.35
CONCRETE:
3.1 Concrete shall be mixed, proportioned, conveyed and placed in accordance with IBC Chapter 19 and ACI 318-14. Mix shall be proportioned to produce a
slump of 5" or less. All concrete with surfaces exposed to standing water shall be air -entrained with an air -content conforming to ACI 318-14 Table 19.3.3.1
Concrete Strength, based on IBC Section 1904.1, shall be as follows:
Type or Location of Concrete Construction
(Moderate Exposure)
Min. 28-Day Compressive Strength, f'c
Interior Slabs -on -Grade
2500-psi
Footings, Basement Walls, Foundation/Stem Walls
3000-psis
� Specified compressive strength (f�) specifications address serviceability requirements. Design
strength of concrete is 2500-psi, therefore, strength tests are not required. Provided concrete mix
tickets verifying strength specifications.
3.2 Reinforcing Steel shall conform to ASTM A615/A615M-18e1 and the following:
Bar Size
Steel Grade
#5 bar and larger
Grade 60, fy = 60,000-psi
#4 bar and smaller
Grade 40, fy = 40,000-psi
Welded Wire Fabric shall conform to ASTM A1064/A1064M-18a
3.3 Reinforcing Steel shall be detailed (including hooks and bends) in accordance with ACI 318-14. Lap all continuous reinforcement (#5 and smaller) 2'-0"
minimum. Laps of larger bars (#6 and #7) shall be 3'-0", min. Provide corner bars at all wall and footing intersections and lap 2'-0" minimum. Lap adjacent
mats of welded wire fabric a minimum of 8" at sides and ends.
No bars partially embedded in hardened concrete shall be field bent unless otherwise noted on the drawings or approved by the structural engineer.
3.4 Concrete Protection (cover) for Reinforcing Steel shall be as follows:
Condition
Clear Cover
Footings and Unformed Surfaces cast against and permanently exposed to Earth
3"
Formed Surfaces exposed to Earth or Weather (#6 bars or larger)
2"
Formed Surfaces exposed to Earth or Weather (#5 bars or smaller)
1%2"
Slabs and Walls, interior face (#11 bars and smaller)
3/a"
Column Ties or Spirals and Beam Stirrups
1%2"
WOOD:
6.1 Framing Lumber shall be kiln dried or MC-19, and graded and marked in conformance with WCLB Standard Grading Rules for West Coast Lumber No. 17
Unless otherwise noted, furnish to the following minimum standards:
Member Use
Size
Species
Grade
Studs
2x, 3x
Hem -Fir or SPF
STUD
Joists/Rafters
2x, 3x
Hem -Fir
No. 2
Plates/Misc.
2x, 3x
Hem -Fir
No. 2
Beams
4x
Douglas Fir -Larch
No. 2
Posts
4x
Douglas Fir -Larch
No. 2
Timber, Beams
6x &Larger
Douglas Fir -Larch
No. 2
Timber, Posts
6x &Larger
Douglas Fir -Larch
No. 2
6.2 Glued Laminated Members shall be fabricated in conformance with ASTM and AITC Standards. Each member shall bear an AITC Identification Mark and
shall be accompanied by an AITC certificate of conformance. Furnish to the following minimum standards:
Member Use
Combination
Species
FbX+
FbX_
F�lX
FAX
EX
Beams
24F-V4
DF/DF
2400-psi
1850-psi
650-psi
265-psi
1800-ksi
Camber all glulam beams to 3,500' radius, unless otherwise noted. Glued laminated members exposed to
weather or moisture shall be treated with an approved preservative.
6.3 Engineered Wood shown on the drawings are based on product manufactured by Weyerhaeuser in accordance with ICC Report No. ES ESR-1387.
Alternate manufacturers may be used subject to review and approval by the Architect and Structural Engineer. All hangers and other hardware not shown
shall be designed and supplied by the Joist Manufacturer. Each piece shall bear a stamp or stamps noting the name and plant number of the manufacturer,
the grade, the ICC report number, and the quality control agency. Furnish to the following minimum standards:
Member Use
Product
Fb
F�l
F�
E
Beams
1.55E Laminated Strand Lumber (LSL)
2325-psi
800-psi
310-psi
1550-ksi
Beams
2.0E Laminated Veneer Lumber (LVL)
2600-psi
750-psi
285-psi
2000-ksi
Beams
2.0E Parallel Strand Lumber (PSL)
2900-psi
750-psi
290-psi
2000-ksi
Rim Boards
Laminated Strand Lumber (LSL)
1700-psi
680-psi
400-psi
1300-ksi
6.4 Engineered Wood I -Joists shown on the drawings are based on joists manufactured by Weyerhaeuser in accordance with ICC Report No. ES ESR-1153.
Alternate Engineered Wood I -Joists manufacturers may be used subject to review and approval by the Architect and Structural Engineer.
6.5 Prefabricated Connector Plate Wood Trusses shall be designed by the manufacturer in accordance with TPI 1-2014 for the spans and conditions shown on
the drawings. Wood trusses shall utilize approved connector plates (MITEK, ITW or other approved Truss Plate Manufacturer).
Unless otherwise noted, loading shall be as follows:
Roof Truss Design Loading
Member
Uniform Load
Top Chord Snow Load
Top Chord Wind Load (Uplift)
25-psf
15-psf
Top Chord Dead Load
7-psf
Bottom Chord Live Load
10-psf
Bottom Chord Dead Load
5-psf
Floor Truss Design Loading
Member
Uniform Load
Top Chord Live Load
40-psf
Top Chord Dead Load
10-psf
Bottom Chord Dead Load
5-psf
Submit shop drawings and design calculations prior to fabrication. Submitted documents shall bear the stamp and signature of a registered Professional
Engineer, State of Washington. Truss design drawings shall include, at a minimum, the following:
A. Slope or Depth, Span and Spacing
B. Location of all Joints and Support Locations
C. Number of Plies if greater than one
D. Required Bearing Widths
E. Design Loads and Locations: Include Top and Bottom Chord Live and Dead Loads, Girder Loads, and Environmental Loads (Seismic, Wind, Snow, etc.)
F. Other Lateral Loads, including Drag Strut Loads
G. Adjustments to Wood and Metal Connector Plate Design Value for Conditions of Use
H. Maximum Reaction Force and Direction (including Maximum Uplift)
I. Metal -Connector -Plate Type, Size, Thickness, and Location
J. Size Species and Grade for each Member
K. Truss -to -Truss Connections and Truss Field Assembly Requirements
L. Calculated Span -to -Deflection Ratio and maximum Vertical and Horizontal Deflection for Live and Total Loads
M. Maximum Axial Tension and Compression Forces in each Truss Member
N. Required Permanent Individual Truss Member Restraint Location and the Method and Details of Restraint Bracing to be used
O. Placement Layout including Bearing Points, Intersections, Hips, Valleys, etc.
P. Truss -to -Truss and Truss -to -Beam Connection Details and Hardware
6.6 Roof, Floor &Wall Sheathing shall be APA Rated, Exterior or Exposure 1 Plywood or OSB manufactured under the provisions of Voluntary Product
Standards DOC PS-1 or DOC PS-2, or APA PRP-108 Performance Standards and Policies for Structural Use Panels. See Drawings for thickness, span
rating, and nailing requirements. Unless otherwise noted, wall sheathing shall be''/z" (nominal) with Span Rating of 24/0. Glue floor sheathing to all
supporting members with adhesive conforming to APA Specification AFG-01.
6.7 Wood members shall be protected against decay and termites in accordance with IBC Section 2304.12. Where required, members shall be naturally durable
species or shall be treated with waterborne preservatives wood in accordance with American Wood Protection Association specification AWPA U1. Members
shall be clearly labeled. Modifed treated members (ripped or end cut) shall be field treated in accordance with specification AWPA M4.
WOOD (Continued):
6.8 Timber Connectors and Proprietary Fasteners shall be "Strong -Tie" by Simpson Company, as specified in their current catalog. Provide number and size of
fasteners as specified by manufacturer. Connectors shall be installed in accordance with the manufacturer's instructions. Where connector straps connect
two members, center strap on joint and provide number and size of fasteners as specified by manufacturer, with equal number and size of fasteners in each
member.
Alternate hardware manufacturer substitutions, such as USP Connectors, shall be ICC approval for equal or greater load capacities. All joist hangers and
other hardware shall be compatible in size with specified framing members. See Hanger Conversion Table for pre -approved substitutions.
Timber Connectors and their fasteners shall be protected from corrosion in accordance with manufacturer's recommendations or ASTM A 653, Type G185.
6.9 Dowel -Type Fasteners (Bolts, Lag Screws, Wood Screws and Nails) shall conform to Sections 11 and 12 of the ANSI/AWC NDS-2018.
Dowel Type Fastener
Grade
Requirements at Exterior Use or
Installation
when in Contact w/ Treated Lumber
ASTM B 695, Class 55 Galvanized
Bolts
ASTM A307
ANSI/AWC NDS-2018 Section 12.1.3
or Stainless Steel
Hole = Bolt O + (1/32" to 1/16")
Washer @Bolt Head and @Nut
All-Thread/Threaded Rod
ASTM F1554
ASTM B 695, Class 55 Galvanized
ANSI/AWC NDS-2018 Section 12.1.3
or Stainless Steel
Hole =Rod Q1 + (1/32" to 1/16")
Washer @Each Nut
Lag Screws
ASTM A307
ASTM A 153 Galvanized
ANSI/AWC NDS-2018 Section 12.1.4
or Stainless Steel
Lead Hole = 0.5 x Shank !D; Shank Hole =Shank O
Washer @Lag Head
Wood Screws
ASTM A 153 Galvanized
ANSI/AWC NDS-2018 Section 12.1.5
or Stainless Steel
Pilot Hole = 0.75 x Root 0 (Unless Self -Boring)
Nails
ASTM F1667
ASTM A 153 Galvanized
ANSI/AWC NDS-2018 Section 12.1.E
or Stainless Steel
Avoid Overdriving or Underdriving; Avoid Wood Splitting
Toenails 30°, 1/3 Nail Length from Joint
Nails specified on the drawings shall be as follows:
Nail Use
Penny
Weight
Grade
Framing Nails
12d Box
0.131 "!D x 3%4"
Sheathing Nails
8d Common
0.131"Ql x 2%2"
a�
.L
''W^
VJ
N
O� _
• �U
•
A�
All Metal Fasteners exposed to weather or in contact with treated wood shall be protected from corrosion according to table above. Nuts and bolts exposed
to weather or in contact with treated wood shall be galvanized in accordance with ASTM A153/A153M-16a or Stainless Steel. See above for Proprietary
Fastener requirements. Do not substitute standard Dowel -Type Fasteners for Proprietary Fasteners unless specifically allowed.
��
6.10 Wood Framing Notes: The following apply unless otherwise noted on the drawings:
(�
A. All wood framing details shall be constructed to the minimum standards of the IBC. Nailing not specified on the drawings shall conform to IBC Table
�
Z
2304.10.1 or ICC ES ESR-1539. Coordinate the size and location of all openings with Mechanical and Architectural Drawings.
O
B. Wall Framing: Stud wall size and spacing shall be in accordance with the plan notes. Two studs minimum shall be provided at the ends of all walls, at
O
each side of all openings, and at the ends of all beams and headers. All stud bearing walls on wood framing shall have their lower wood plates attached
to framing or concrete below per P1-6 of the shear wall schedule.
C. Individual members of Built -Up stud posts shall be nailed to each other with framing nails @ 12"oc, staggered. Individual members of Built -Up joist
framing
beams shall be nailed to each other with nails @ 12"oc, staggered.
`�
D. Solid blocking for wood columns shall be provided through floors to supports below.
E. Floor and Roof Framing: Provide solid blocking at all bearing points. Toenail joists to supports with two framing nails. Attach timber joists to flush
headers or beams with metal joist hangers in accordance with notes above.
F. Roof and floor sheathing shall be laid up with grain perpendicular to supports and nailed per plan notes. Allow 1/8" spacing at all panel edges and ends
J
of floor and roof sheathing. Provide approved panel edge clips centered between joists/trusses at unblocked roof sheathing edges. All floor sheathing
have tongue Toenail blocking to framing 12"oc. At blocked floor diaphragms,
edges shall approved -and -groove joints. supports with nails @ and roof
provide flat 2x blocking at all unframed panel edges and nail with edge nailing specified.
�
_M
W
QUALITY ASSURANCE:
7.1 Special Inspection shall be in accordance with IBC Section 1704.2. Standard inspections shall be in accordance with IBC Section 110.
O
7.2 Structural Observation in accordance with IBC Section 1704.E is not required.
V
W
o
O
O�
J
�
0
a
J
LL
O
W�
�
Z
W
�
z
�
U
U
_~
�/�
�/ �
�
J
�_
m
H
w
a
M
w
o
�
N
0
RECEIVED
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
2
S08
li
(3)2 6
WALL SHTG
CONT.THRU
CORNER
PER
13/S07
8 1
S06 S08
3%�1� B
0
ADJUST SPACING AS REO'
FOR PLUMBING, TYP. (SEE
A6 FOR PLUMBING DROP
DIMENSIONS)
ADJUST SPACING
REO'D FOR MECH.
18" DEEP GIRDER
STRUT TRUSS (F)
(DRAG LOAD = 2000LB)
HU612
(1600#
LOAD)
S08 HUCQ412-:
3%zx15 GLB (F)
RAISED HEEL
MONO TRUSSES
@ 24"oc
5%zx15 GLB
(EXTEND TO
CORNERS)
��
��
<Q
3%x12 GLB
18" OPEN WEB
FLOOR TRUSSES
� 24"oc, TYP UNC
S08 / S1 08 /
DSC2-SDS3
STRUT TO
PLATE
WALL SHTG
CONT.THRU
CORNER
11
S08
7 3%zx15 GLB (F)
CS 16x48" �'
PER 18/S08 11
S09
PER
13/S07
15" DEEP GIRDER
TRUSS (F)
H
0
z
w
18" DEEP GIRDER
STRUT TRUSS (F)
(DRAG LOAD =
1000LB)
3
S08
�15" DEEP GIRDS
TRUSS (F)
o MONO
Z TRUSSES\
w
@ 24"oc
(2)2x6 1�
HUC410
TO POST
�4x10 (DROPPI
GIRDER GABLE
END TRUSS
12 GLB
X
N
CV
2
sob
CS16x6'-0" -LAP LOWER
TOP PLATE 1'-4" AND
ATTACH TO FLAT 2x4
cn I I
BLKG BTWN STUDS
� I I
li
I
p I I
Z I I
�
�
� �_
w I I
� �
HDR
cx
-
�
LL N
O�
O�
QO
mp
CS16x6'-0" -LAP LOWER
TOP PLATE 1'-4" AND
K6 WALL
ATTACH TO FLAT 2x4
BLKG BTWN STUDS
Q
z
w
� `x° 8
o S06
2x4 LEDGER AT TOP
& BOTT. CHORD W/
(2) 12d EA STUD
� O
/Q1212�6
— BALLOON FRAME 1
TO ROOF W/ (2) S08
6 2x6 @ 16"oc
�2)2x62)2x6
GIRDER
TRUSS
8 8
S06 S06
CS16x60"
PER 17/S08
3%zx7%z GLB
C�
so
d'
FLOOR FRAMING PLAN NOTES:
1. Floor Sheathing shall be 3/0" thick T&G (Panel Span Rating 48/24) with long dimension perpendicular to supports. Glue Sheathing
to all Framing Members and Blocking below with adhesive conforming to A.P.A.Specification AFG-01. Fasten Sheathing to
Framing with 0.131 "O x 2%z" Nails or Simpson WSV #9x2%2" screws as follows:
Framing, Edges
6"oc
Framing, Field
10"oc
Boundaries, Blocking, Struts
6"oc
At areas indicated as Blocked Diaphragm, provide 2x Flat Blocking (per General Structural Notes) at all Unframed Sheathing Panel
Edges. Fasten Sheathing to Framing and Blocking with 0.131 "O x 2%Z' Nails or Simpson WSV #9x2%2" screws as follows:
Framing, Edges
4"oc
Framing, Field
10"oc
Boundaries, Blocking, Struts
4"oc
See Drawings for other Sheathing Nailing requirements.
2. Floor Framing shall be as indicated on plan. Change spacing, as required, to meet the deflection requirements. Loading shall be
as follows, u.o.n.:
Top Chord Live Load
40-psf
Top Chord Dead Load
10-psf
Bottom Chord Live Load
N/A
Bottom Chord Dead Load
5-psf
Maximum Live Load deflection shall be L/480. Refer to General Structural Notes for other requirements.
ROOF FRAMING PLAN NOTES:
3. Roof Sheathing shall be �/6" thick (Panel Span Rating 24/16). Fasten Sheathing to Framing with 0.131 "QJ x 2%Z' Nails as follows:
Framing, Edges
6"oc
Framing, Field
12"oc
Boundaries, Blocking, Struts
6"oc
At Unframed Panel Edges, provide PSCA Framing Clips centered between each Framing Member. See Drawings for other
Sheathing Nailing requirements.
At areas indicated as Blocked Diaphragm, provide 2x Flat Blocking (per General Structural Notes) at all Unframed Sheathing Panel
Edges. Fasten Sheathing to Framing and Blocking with 0.131 "O x 2%Z' Nails as follows:
Framing, Edges
4"oc
Framing, Field
12"oc
Boundaries, Blocking, Struts
4"oc
See Drawings for other Sheathing Nailing requirements.
4. Roof Framing shall be as indicated on plan. Refer to General Structural Notes.
5. Trusses marked Strut shall be designed to accommodate the indicated loads and connections.
6. Overframing Members shall be 2x4 @ 24"oc posted down to main framing below w/ 2x4 @ 48"oc, staggered, or as indicated by the
Truss Manufacturer.
7. Provide solid Flat Blocking at all Valleys. Fasten Sheathing to Blocking in accordance with Note 3.
8. Provide H2.5A Clip each side or TLOK6 Screw each ply at 2-ply or greater Girder Truss ends, typ.
WALL FRAMING PLAN NOTES:
9. Exterior Walls shall be Shear Wall type P1-6 with 2x6 Studs @ 16"oc, u.o.n.
Interior Bearing Walls shall be 2x4 Studs @ 16"oc, u.o.n. Interior Non -Bearing Walls shall be 2x4 studs @ 24"oc.
Where adjacent Shear Walls are in contact, nail studs together per 3/S06. See 1/S06 for special stud requirements at Shear Wall
types P1-3, P1-2, and P2-2.
10. Headers shall be 4x6, u.o.n. See Detail 13/S06.
11. Built-up Stud Groups in Walls supporting Beams, Posts or Girder Trusses above shall be (2) Studs, u.o.n. See General Structural
Notes for fastening requirements.
12. See 10/S06 for Simpson to USP hardware conversion table.
LEGEND
XX
SX.X i
_�
P1-X
0
�---�
(F)
PT. LD.
HDR
DETAIL CALL -OUT
SHEAR WALL BELOW PER SCHEDULE OF 1/S06
BEARING OR SHEAR WALL BELOW
BEARING OR SHEAR WALL ABOVE
FLUSH FRAMED (BOTTOM FLUSH W/ BOTTOM OF FRAMING)
POST BELOW
BLOCK THRU FLOOR FOR POST ABOVE
HEADER PER PLAN NOTE 10
RECEIVED
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
N
�^L^,,
/rW^
VJ
W
��
_�_
• U
•
A�
N
• � N
I/"''�I �
N � N
7 W � �
1`� �
ry 4
W is
W 0��
�5�
� ���
Q�
:� o
��a
�-� .. o
W c
1 T.
of �SH�
M�� �—
W W
J
Ofwn
V
�� Q
z
Q
w
O w
Q
0
Zo
O
�
0
O
^J
I..L
w
J
O
v
�
�/
Z
U
W�
z
��
U_
I..L
�
�_
J
m
H
w
d
M
w o
� N
O
w
SO4A(M)
0 1 2 4 8 16
—ADJUST STUD FRAMIN�
AS REQUIRED
MUDSILL
ii
ii
ii
II
II
�ii
PER PLAN
�i
ii
u u
a ii
u u
u u
u u
�,
u u
u u
�,
a°
° Q a ° a ° a
°
°a � °d a � � LSL / VER;
a � °
� RIM BOAR
° �. LOCATE VENTS BETWEEN PLAN
° ° JOISTS & 1'-0" MIN. FROM
° a a as d HOEDOWNS &POINT LOADS
° a a � a � �� � �� � � � ��,
° a c a `
a°
a °
�, a .. -
a a
a° ° a ° a e a �a _..
POST PER PLAN
SLAB -ON -GRADE
PER PLAN
' e
DIAPHRAGM BOUNDARY
NAILING
SHEATHING PER PLAN —
JOISTS PER PLAN
��
UNBALANCED
FILL
A -LAM
� PER
FOOTINGS AND STEM��
WALLS PER PLAN
20
POST BASE PER PLAN W/
ALL -THREAD (SIZE PER MFR) AND
2%2" SIMPSON SET EPDXY EMBED
(NO SPECIAL INSPECTION REO'D)
� ° `�°
>� �
° °°I III III III III
III —III —III —III —I
a I III III III Ili=
° III=1 I I=1 I I-1 �'
g ' —I l l � i 11 1 1=' '
STEM WALL AND FOOTING
PER 1/S07
15
SHEATHING PER 1/S06
j 2x STUD WALL PER PLAN
12d @ 6"oc TO RIM
SHEAR WALL EDGE NAILING
SPLICE SHEATHING
AS REQUIRED
SHEAR WALL EDGE NAILING
` 15�s" VERSA -LAM 1.4E 1800
\ RIM BOARD (ALT: 1%4' LSL
RIM BOARD)
— 15�s" VERSA -LAM / 1%4" LSL
BLOCKING W/ 12d TOENAILS
@ 6"oc
MUDSILL &ANCHOR
BOLTS PER 1/S07
STEM WALL AND FOOTING
(1)#4 x 36" DIAGONAL
0
_�
MUD:
JOIST
PER 1/S07 SEE 8/S07
3'-0" MIN. D
n
Q
NORMAL FOOTING
REINFORCING
1 O FOR CALL -OUTS
IN COMMON
15is" VERSA -LAM / 1�4" LSL
BLOCKING WHERE BEARING
WALL OCCURS
SIZE
REINFORCING
CAL OUT
REFERENCE
18
18" sq x 12" thick
NO REINF.
(2) #4 EA. WAY
-
-
24
24" sq x 12" thick
BOTTOM
30
30" sq x 12" thick
(3) #4 EA. WAY
-
BOTTOM
36
36" sq x 12" thick
(4) #4 EA. WAY
BOTTOM
42
42" sq x 12" thick
(5) #4 EA. WAY
-
BOTTOM
5
BEAM PER PLAN
1x4 x 12" EA. SIDE
w/ (4) 12d EA.
MEMBER
MAB15, POST TO FOOTING -
U.O.N ON PLAN (ALT: A34
CLIP EA. SIDE W/ 0.131"(D x 2"
MIN. CONC. NAILS TO FTG)
REINF. PER PLAN �
Trio orinir oro
19
I -NORMAL FOOTING
REINFORCING
—ADD'L BARS TO
MATCH NORMAL
REINFORCING
NE OF EXCAVATION
STEP IN FOOTING
14
BEARING WALL
(WHERE OCCURS)
POST PER PLAN
(2) LAYERS BLDG PAPER BTWN
POST AND CONC.
FOOTING
PER PLAN
CONT. TOP PLATE PER 18/S06
O O o ° ° O O o °
—o 0 0 0 _° — — _° o o —° —
— — — io ---- — — — i a
i i
i i i
—
i i--
i
i
i i
i° i i°i
i i°� i � i
PANEL EDGE
� � �
°i i i
i i i
i°i ° i
iii i
NAILING
iii i
°� °
-- — 1 -- — — — 1
i —PANEL EDGE
°
8 0
°
°
° �
NAILING
FULL HEIGHT
°
O O O O O O
(HALF EA. STUD)
—
— --
— —
HEADER PER PLAN
°�
i°� i
°
(EXTEND TO CORNER)
°
PER PLAN
°
°
° °
((2)2x MIN.)
O
(2)2x
ADD'L STUD
z
g
a
HOLD DOWN PER PLAN
�
w
(APPLY OVER SHEATHING)
�
2
ANCHOR
BOLTS PER 1/S06
PER PLAN
P.T.
2x6 MUDSILL UNO
�
°d d°
� ()
4
p
#4 @ 16"oc,
8" STEMWALL UNO
O
�
d
O
d d
®
HORIZ
a d
�
1%Z' TYP.
°
da d
�
d
� �
#4 @ 16"oc, VERT
FOOTING PER 1/S07
�
(HOOK AROUND
d
a d
FTG. REINF.)
a
d
a
a a
a
d
a d d
DIAPHRAGM BOUNDARY NAILING
PT 2x8 MUDSILL RIPPED TO
MATCH STEMWALL WIDTH W/
A.B.'S AND PLATE WASHERS
PER 1/S06
SHEATHING PER PLAN
13
(2)2x STUD -NAIL SHEATHING
TO EACH MEMBER w/ HALF OF
SHEATHING NAILS
STRAP HOLD DOWN PER PLAN
APPLIED OVER SHEATHING
ANCHOR BOLTS PER 1/S06
*NO NAILS STEM WALL PER
BOTTOM 2 FOUNDATION PLAN
HOLES
------- d
a d
i a a i
® � d ° ��
a dQ d
�a
I a a
a d a � d 4 d a d d O 4
1 � �� a
2 a a
Q d d d Q
� p 4 �
d d ---- Q Q O d d
O 4 � Q O
d d Q
d d
Q ---- O d d d � a
17
2x STUD WALL PER PLAN
(2) 2x6 PT MUDSILL
SLAB -ON -GRADE 5's"O ALL -THREAD W/ PLATE
PER PLAN WASHERS PER 1/S06 AND 2�2"
SIMPSON SET EPDXY EMBED
(NO SPECIAL INSPECTION REO'D)
° ° p a ° � a a ° � ° u ° d
< _
I I 1-1 11=1 11=1 � 1=1 11-� � °
II III III -III- � I I III III=�
— IIIIIIIIIII III=III—I
�` a I III III III �,111=
° � IIII IIIIIIIII�, I a
8 ° -�I-- a
—STEM WALL AND FOOTING d
PER 1/S07 a
SHEATHING PER 1/S06
PROVIDE SQUASH BLK'G
2x STUD WALL PER PLAN UNDER POSTS AND BUILT UP
STUDS ABOVE (MATCH SIZE
ABOVE)
FACENAIL PER 1/S06
SHEATHING
NAILS @ 4"oc
PANEL EDGE NAILING
i
i
JOISTS PER PLAN
III
UNBALANCED FILL
JOISTS PER PLAN i
i
ITS2.37/9.5 HANGERS
d
JOIST BLOCKING @ 48"oc d �'
(ALT: ITS2.06/9.5
(NOT REQUIRED IF a
HANGERS AT TJI 210'S)
STEM WALL &FOOTING
UNBALANCED FILL < 1'-0")
(2) LAYERS BUILDING PAPER
PER 1/S07
°
BETWEEN JOISTS &STEM WALL
--I �
-III
SEE 6/S07
FOR CALL -OUTS
9
Q
IN COMMON
SLAB -ON -GRADE
PER ARCH'L DRIVEWAY PER ARCH'L
° e ° a ° ° � a � - .
III_=1 I I-1 I I-1 I I-1 I I-�
11 .,111,,,111,,,111 °
d COMPACT STRUCTURAL
°0 a ° FILL
a� � a
REINF. PER 1/S07
1'-3"
3
2x STUD WALL PER PLAN
MUDSILL PER 1/S07
SLAB -ON -GRADE
PER PLAN
ri X
i
�u
gl�
d°
d
UNBALANCED
FILL
SHEATHING PER 1/S06
PANEL EDGE NAILING
STEM WALL AND FOOTING
PER 1/S07
12
7
DIAPHRAGM BOUNDARY
NAILING
(2)2x STUD -NAIL SHEATHING
TO EACH MEMBER w/ HALF OF
SHEATHING NAILS
I
STRAP HOLD DOWN PER PLAN
APPLIED OVER SHEATHING
ANCHOR BOLTS PER 1/S06
,/
U
STEM WALL PER
FOUNDATION PLAN
I
— — — — — — —
ii a iia
®� �I �
® i a a o f
a
® �a d dd d �
4 a
Ia
a
�d d
Q O d d
1 �2"
a � a a
4
O °
�
— — — —
4 �i
d a
;�(2)2x STUD -NAIL SHEATHING
TO EACH MEMBER w/ HALF OF
SHEATHING NAILS
STRAP HOLD DOWN PER PLAN
APPLIED OVER SHEATHING
SOLID BLOCKING
12"
i
i
4 d
®a i i
i a a i
® � � a�
® a d dQ d 40
a ald
a
1�2�� d� d a
d STEM WALL PER
`FOUNDATION PLAN �
---- a a
a a
a
d a ° ANCHOR BOLTS PER 1/S06
PROVIDE SQUASH BLK'G
UNDER POSTS AND BUILT UP
STUDS ABOVE (MATCH SIZE
ABOVE)
JOISTS PER PLAN
15�s" VERSA -LAM 1.4E 180
RIM BOARD (ALT: 1�4" LSL
RIM BOARD)
2x6 P.T. PLATE W/
MUDSILL ANCHORS
PER 1/S06
2x6 P.T. PLATE
w/ A.B.'s AND PLATE
WASHERS PER 1/S06
#4, TOP (LOCATE IN TOP
12" OF STEMWALL)
#4 @ 36"oc, VERT. HOOKED BAR
#4 @ 24"oc, HORIZ.
(1)#4, BOTTOM
16
SHEATHING PER 1/S06
�2x STUD WALL PER PLAN
— 12d @ 6"oc
SHEAR WALL EDGE NAILING
�` SPLICE SHEATHING
—SHEAR WALL EDGE NAILING
STEM WALL AND FOOTING
PER 1/S07
ALT. MUDSILL ANCHOR
4'-0" MAX
UNBALANCED
FILL
�������Ii���— �
.III
Z_
��I I
=11=1 I I=1 I I I � I-
III III —III='
4i2" 6" 4i2� TYP. RECEIVE D
1'-3"
Jun 08 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
N
�L
N
O \�
` �
• U
�;� ,;; � d
�/
�`. �.
��
O
O
��
�
-
�
°°
0
Q
CO
G
' ^ w
J O
U
W o
_U
�_
J
Q
�_
m
H
W
d
M
W O
� N
0
w
S07