Loading...
APPROVED RESUB1 FIR2023-0042+Fire_Sprinkler_Plan+6.13.2023_2.33.38_PM+3606920N NTS SITE PLAN NWFS START POINTIN MECH ROOM@ STUB 3'-0 F.F. NEW HOUSE LOCATIONAPPROXIMATE 1" WATER METERBY OTHERS 4" U G 2" P O L Y U G BY O T H E R S 1 JOB NUMBER -- F I L E : S U N S E T _ F P X . X X _ ( H o m e s ) 2 0 2 3 . c a d D A T E : 0 6 / 1 3 / 2 3 T I M E : 1 4 : 0 7 : 4 5 - - DESIGNER PARCEL # Job Number: Drawing No. Sunset Residence Drawing Title June 13, 2023 01117R Date: NICET Stamp 332 Sunset Ave N Edmonds, WA 98020 Jessica BoxDesigner: 1 - 06.13.23 City of Edmonds Review Revisions SITE PLAN/ SECTION/ RISER Contract Name: 1. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED. 2. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 3. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. 4. ALL PIPE TO BE CPVC U.N.O 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 SQ. FT OR LESS 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT ARE LESS THEN 24 SQ. FT., THE LEAST DIMENSIONS DOES NOT EXCEED 3-0 AND THE ROOM IS SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS. 7. SPRINKLER SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, CONCEALED SPACES, FLOOR/CEILING SPACES, CRAWL SPACES AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTEDED FOR LIVING PURPOSES AND DO NOT CANTAIN FUEL-FIRED EQUIPMENT. 9. WIREING OF ANY NEW DEVICES IF REQUIRED IS BY OTHERS 10 PAINTING OR LABELING OF PIPING IF REQUIRED IS BY OTHERS. FIRE SPRINKLES SHALL NOT BE PAINTED OVER 11. IT SHALL BE THE OWNERS RESPONSIBILITY TO MAINTAIN THE TEMPERATURE ABOVE 40° AT ALL TIMES. 12. A MAIN DRAIN IS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA-13D. HUB-DRAINS TO BE PROVIDED BY OTHERS AS NEEDED. 13 NO GYP. BD. CEILINGS SHALL BE INSTALLED UNTIL ROUGH IN VISUAL INSPECTION IS COMPLETE 14. MAXIMUM RESIDENTIAL PENDENT SPRINKLER SPACING 16' X 16'. MAXIMUM DRY SIDEWALL SPRINKLER SPACING 14' X 14'. MAXIMUM RESIDENTIAL SIDEWALL SPRINKLER SPACING 16' X 20' 15. MINIMUM RESIDENTIAL PENDENT SPRINKLER SPACING 8-0 O.C.. MINIMUM DRY SIDEWAL SPRINKLER SPACING 6-0 O.C. MINIMUM RESIDENTIAL SIDEWALL SPRINKLER SPACING IS 8-0 O.C. 16. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA 13D 17 PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CHORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. WATER FLOW INFORMATION IS PER EDMONDS UTILITIES/ ENGINEERING COMPUTER MODEL ANALYSIS OF FIREFLOW STATIC: 100 PSI, RESIDUAL: 20 PSI, FLOW 1000 GPM Sp r i n k l e r L e g e n d - E n t i r e P r o j e c t Sy m Ma n u SI N Mo d e l K- F a Ty p e Si z e Re s p Fi n Te m p No t e Qt y Vi k i n g VK 4 9 4 FR E E D O M 4. 9 Pe n d e n t ½ Qu i c k Wh i t e 16 5 ° F SQ U A R E C O N C E A L E D C O V E R 49 Vi k i n g VK 3 0 2 Mi c r o f a s t 5. 6 Pe n d e n t ½ Qu i c k Wh i t e P o l y e s t e r 28 6 ° F SE M I R E C E S S E D 2 Re l i a b l e RA 5 2 3 1 F3 R E S 4 4 D R Y H S W 4. 4 Si d e w a l l ¾ Qu i c k Wh i t e P o l y e s t e r 15 5 ° F 1 To t a l = 5 2 www.nwfiresystems.com LIC # NORTHFS928CR Ph: 206.772.7502 * Fax: 206.772.7504 NORTHWEST FIRE SYSTEMS 22645 83rd ave. S., Bldg D *Kent, WA 98032 FLOW ALL HEADS IN A COMPARTMENT TO A MAXIMUM OF TWO PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO: BACKFILL, SELECT FILL, BREAKING PATCHING, SAW CUTTING, LAWN REPAIR, LANDSCAPING, TREE REMOVAL, STERILIZATION, DEVELOPMENT FEES AND CITY CONNECTION. HOUSE - 13D EXCLUSIONS IN THE MOST DEMANDING LOCATION PER NFPA 13D(2016) SCOPE OF WORK DESIGN CRITERIA GENERAL NOTES DRAWING INDEX WATER SUPPLY INFORMATION NORTHWEST FIRE PROTECTION (NWFS) WILL PROVIDE (1) WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. NWFS START POINT WILL BE IN THE MECH ROOM AT THE STUP UP LOCATION AFTER BACKFLOW TO SUPPLY THE SPRINKLER SYSTEM. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING. FP 0.10 FP 1.10 FIRE SPRINKLER PLAN MAIN FLOOR SITE, CROSS SECTION, NOTES AND SYMBOLSFP 0.10 FP 1.20 FIRE SPRINKLER PLAN 2ND FLOOR Denise Gomez Gonzalez 2293-0722-B Northwest Fire Systems, LLC NORTHFS928CR 06 / 1 3 / 2 0 2 3 -- F I L E : S U N S E T _ F P X . X X _ ( H o m e s ) 2 0 2 3 . c a d D A T E : 0 6 / 1 3 / 2 3 T I M E : 1 4 : 0 3 : 2 5 - - JOB NUMBERDESIGNER Drawing No. Designer: Date: Job Number: Jessica Box 01117R PARCEL # June 13, 2023 Sunset Residence Drawing Title NICET Stamp 332 Sunset Ave N Edmonds, WA 98020 Revisions MAIN FLOOR FIRE SPRINKLER PLAN Contract Name: www.nwfiresystems.com LIC # NORTHFS928CR Ph: 206.772.7502 * Fax: 206.772.7504 NORTHWEST FIRE SYSTEMS 22645 83rd ave. S., Bldg D *Kent, WA 98032 FP 1.10 Denise Gomez Gonzalez 2293-0722-B Northwest Fire Systems, LLC NORTHFS928CR 06 / 1 3 / 2 0 2 3 -- F I L E : S U N S E T _ F P X . X X _ ( H o m e s ) 2 0 2 3 . c a d D A T E : 0 6 / 1 3 / 2 3 T I M E : 1 4 : 0 4 : 2 5 - - JOB NUMBERDESIGNER Drawing No. Designer: Date: Job Number: Jessica Box 01117R PARCEL # June 13, 2023 Sunset Residence Drawing Title NICET Stamp 332 Sunset Ave N Edmonds, WA 98020 Revisions 2nd FLOOR FIRE SPRINKLER PLAN Contract Name: www.nwfiresystems.com LIC # NORTHFS928CR Ph: 206.772.7502 * Fax: 206.772.7504 NORTHWEST FIRE SYSTEMS 22645 83rd ave. S., Bldg D *Kent, WA 98032 FP 1.20 Denise Gomez Gonzalez 2293-0722-B Northwest Fire Systems, LLC NORTHFS928CR 06 / 1 3 / 2 0 2 3