APPROVED RESUB1 FIR2023-0042+Fire_Sprinkler_Plan+6.13.2023_2.33.38_PM+3606920N NTS
SITE PLAN
NWFS START POINTIN MECH ROOM@ STUB 3'-0 F.F.
NEW HOUSE LOCATIONAPPROXIMATE
1" WATER METERBY OTHERS
4" U
G
2"
P
O
L
Y
U
G
BY
O
T
H
E
R
S
1
JOB NUMBER
--
F
I
L
E
:
S
U
N
S
E
T
_
F
P
X
.
X
X
_
(
H
o
m
e
s
)
2
0
2
3
.
c
a
d
D
A
T
E
:
0
6
/
1
3
/
2
3
T
I
M
E
:
1
4
:
0
7
:
4
5
-
-
DESIGNER
PARCEL #
Job Number:
Drawing No.
Sunset Residence
Drawing Title
June 13, 2023
01117R
Date:
NICET Stamp
332 Sunset Ave N
Edmonds, WA 98020
Jessica BoxDesigner:
1 - 06.13.23 City of Edmonds Review
Revisions
SITE PLAN/ SECTION/
RISER
Contract Name:
1. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED.
2. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE
OWNERS RESPONSIBILITY TO PROVIDE HEAT THROUGH OUT THE WET
PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE,
DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER
SUPPLIES TO SPRINKLER SYSTEMS.
3. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR
THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE
SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF.
4. ALL PIPE TO BE CPVC U.N.O
5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 SQ. FT
OR LESS
6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN
CLOSETS, AND PANTRIES THAT ARE LESS THEN 24 SQ. FT., THE LEAST
DIMENSIONS DOES NOT EXCEED 3-0 AND THE ROOM IS SURFACED
WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS.
7. SPRINKLER SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED
PORCHES, CARPORTS, AND SIMILAR STRUCTURES
8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, CONCEALED
SPACES, FLOOR/CEILING SPACES, CRAWL SPACES AND OTHER
CONCEALED SPACES THAT ARE NOT USED OR INTEDED FOR LIVING
PURPOSES AND DO NOT CANTAIN FUEL-FIRED EQUIPMENT.
9. WIREING OF ANY NEW DEVICES IF REQUIRED IS BY OTHERS
10 PAINTING OR LABELING OF PIPING IF REQUIRED IS BY OTHERS. FIRE
SPRINKLES SHALL NOT BE PAINTED OVER
11. IT SHALL BE THE OWNERS RESPONSIBILITY TO MAINTAIN THE
TEMPERATURE ABOVE 40° AT ALL TIMES.
12. A MAIN DRAIN IS TO BE PROVIDED AND INSTALLED IN ACCORDANCE
WITH NFPA-13D. HUB-DRAINS TO BE PROVIDED BY OTHERS AS
NEEDED.
13 NO GYP. BD. CEILINGS SHALL BE INSTALLED UNTIL ROUGH IN VISUAL
INSPECTION IS COMPLETE
14. MAXIMUM RESIDENTIAL PENDENT SPRINKLER SPACING 16' X 16'.
MAXIMUM DRY SIDEWALL SPRINKLER SPACING 14' X 14'. MAXIMUM
RESIDENTIAL SIDEWALL SPRINKLER SPACING 16' X 20'
15. MINIMUM RESIDENTIAL PENDENT SPRINKLER SPACING 8-0 O.C..
MINIMUM DRY SIDEWAL SPRINKLER SPACING 6-0 O.C. MINIMUM
RESIDENTIAL SIDEWALL SPRINKLER SPACING IS 8-0 O.C.
16. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA 13D
17 PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON
THE TOP OF THE BOTTOM TRUSS CHORD ALLOWING FOR TENTING AND
SHALL HAVE PRIORITY OVER OTHER TRADES.
WATER FLOW INFORMATION IS PER EDMONDS UTILITIES/
ENGINEERING
COMPUTER MODEL ANALYSIS OF FIREFLOW
STATIC: 100 PSI, RESIDUAL: 20 PSI, FLOW 1000 GPM
Sp
r
i
n
k
l
e
r
L
e
g
e
n
d
-
E
n
t
i
r
e
P
r
o
j
e
c
t
Sy
m
Ma
n
u
SI
N
Mo
d
e
l
K-
F
a
Ty
p
e
Si
z
e
Re
s
p
Fi
n
Te
m
p
No
t
e
Qt
y
Vi
k
i
n
g
VK
4
9
4
FR
E
E
D
O
M
4.
9
Pe
n
d
e
n
t
½
Qu
i
c
k
Wh
i
t
e
16
5
°
F
SQ
U
A
R
E
C
O
N
C
E
A
L
E
D
C
O
V
E
R
49
Vi
k
i
n
g
VK
3
0
2
Mi
c
r
o
f
a
s
t
5.
6
Pe
n
d
e
n
t
½
Qu
i
c
k
Wh
i
t
e
P
o
l
y
e
s
t
e
r
28
6
°
F
SE
M
I
R
E
C
E
S
S
E
D
2
Re
l
i
a
b
l
e
RA
5
2
3
1
F3
R
E
S
4
4
D
R
Y
H
S
W
4.
4
Si
d
e
w
a
l
l
¾
Qu
i
c
k
Wh
i
t
e
P
o
l
y
e
s
t
e
r
15
5
°
F
1
To
t
a
l
=
5
2
www.nwfiresystems.com LIC # NORTHFS928CR
Ph: 206.772.7502 * Fax: 206.772.7504
NORTHWEST FIRE SYSTEMS
22645 83rd ave. S., Bldg D *Kent, WA 98032
FLOW ALL HEADS IN A COMPARTMENT TO A MAXIMUM OF TWO
PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT
ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO
WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES
CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES
ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO: BACKFILL,
SELECT FILL, BREAKING PATCHING, SAW CUTTING, LAWN REPAIR,
LANDSCAPING, TREE REMOVAL, STERILIZATION, DEVELOPMENT FEES
AND CITY CONNECTION.
HOUSE - 13D
EXCLUSIONS
IN THE MOST DEMANDING LOCATION
PER NFPA 13D(2016)
SCOPE OF WORK
DESIGN CRITERIA
GENERAL NOTES
DRAWING INDEX
WATER SUPPLY INFORMATION
NORTHWEST FIRE PROTECTION (NWFS) WILL PROVIDE (1) WET PIPE
AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. NWFS
START POINT WILL BE IN THE MECH ROOM AT THE STUP UP LOCATION
AFTER BACKFLOW TO SUPPLY THE SPRINKLER SYSTEM.
ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY
OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING.
FP 0.10
FP 1.10 FIRE SPRINKLER PLAN MAIN FLOOR
SITE, CROSS SECTION, NOTES AND SYMBOLSFP 0.10
FP 1.20 FIRE SPRINKLER PLAN 2ND FLOOR
Denise Gomez Gonzalez
2293-0722-B
Northwest Fire Systems, LLC
NORTHFS928CR 06
/
1
3
/
2
0
2
3
--
F
I
L
E
:
S
U
N
S
E
T
_
F
P
X
.
X
X
_
(
H
o
m
e
s
)
2
0
2
3
.
c
a
d
D
A
T
E
:
0
6
/
1
3
/
2
3
T
I
M
E
:
1
4
:
0
3
:
2
5
-
-
JOB NUMBERDESIGNER
Drawing No.
Designer:
Date:
Job Number:
Jessica Box
01117R
PARCEL #
June 13, 2023
Sunset Residence
Drawing Title
NICET Stamp
332 Sunset Ave N
Edmonds, WA 98020
Revisions
MAIN FLOOR
FIRE SPRINKLER PLAN
Contract Name:
www.nwfiresystems.com LIC # NORTHFS928CR
Ph: 206.772.7502 * Fax: 206.772.7504
NORTHWEST FIRE SYSTEMS
22645 83rd ave. S., Bldg D *Kent, WA 98032
FP 1.10
Denise Gomez Gonzalez
2293-0722-B
Northwest Fire Systems, LLC
NORTHFS928CR 06
/
1
3
/
2
0
2
3
--
F
I
L
E
:
S
U
N
S
E
T
_
F
P
X
.
X
X
_
(
H
o
m
e
s
)
2
0
2
3
.
c
a
d
D
A
T
E
:
0
6
/
1
3
/
2
3
T
I
M
E
:
1
4
:
0
4
:
2
5
-
-
JOB NUMBERDESIGNER
Drawing No.
Designer:
Date:
Job Number:
Jessica Box
01117R
PARCEL #
June 13, 2023
Sunset Residence
Drawing Title
NICET Stamp
332 Sunset Ave N
Edmonds, WA 98020
Revisions
2nd FLOOR FIRE
SPRINKLER PLAN
Contract Name:
www.nwfiresystems.com LIC # NORTHFS928CR
Ph: 206.772.7502 * Fax: 206.772.7504
NORTHWEST FIRE SYSTEMS
22645 83rd ave. S., Bldg D *Kent, WA 98032
FP 1.20
Denise Gomez Gonzalez
2293-0722-B
Northwest Fire Systems, LLC
NORTHFS928CR 06
/
1
3
/
2
0
2
3