Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED RESUB1 FIR2023-0042+Calculations+6.13.2023_2.33.39_PM+3606917
Hydraulic Calculations for Project Name: Sunset Residence Location: 332 Sunset Ave N, Edmonds, WA 98020, 27032300100900 Drawinq Name: SUNSET FPX.XX (Homes) 2023.cad Design Remote Area Number: Remote Area Location: Occupancy Classification Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: No. of nozzles calculated: In -rack Demand: Hose Streams: Sunset Residence R-1 Sunset Residence R-1 Residential 0.050 gpm/ft2 900.00 ft2 (Actual 405.10 ft2) 256.00 ft2 Pendent 2 0 N/A gpm at Node: N/A 0.0 gpm at Node: 1 Type: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 26.44 @ 43.471 Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent N/A Name of Contractor: NORTHWEST FIRE SYSTEMS Address: 22645 83rd Ave S. Bldg D, Kent, WA 98032 Phone Number: 253-374-8508 Name of designer: Jessica Box Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Riqht: N/A WASHINGTON STATE � CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Denise Gomez Gonzalez Cl) ; 2293-0722-B c� Northwest Fire Systems, LLC • NORTHFS928CR o a• 3&/,q Expl:7 Slgnatura -� DEC 37,23 L............................ Calculation Date: 6/13/2023 Allowance at Source (Safety Margin = 56.432) L© M.E.P.CAD, Inc. �JJJAutoSPRINK 2022 07.1.17.0 Sunset Residenc 6/13/2023 1:44:38PM Page 1 Job Name: Sunset Residence Remote Area Number: Sunset Residence R-1 150 135 120 105 90 N a 75 U) a� IL` 60 45 30 15 • Hydraulic Graph N 1.85 Date: 6/13/2023 Water Supply Summary Sheet Node: 1 Available Static 26.44 Pressure @ Supply 100.000 99.904 _T7 \�k 26.44 @ 43.471 System demand curve 1000.00 @ 20.000 800 1000 1200 1400 Flow - gpm 1600 1800 2000 &@ M.E.P.CAD, Inc. �jjj AutoSPRINK 2022 v17.1.17.0 6/13/2023 1:44:40PM Paqe 2 4ilsummary Of Outflowing Devices Job Number: 01117R - Sunset Residence R-1 wo -- Keport uescripaon: Kesiaennai (sunset rtesiaence K-i) Device Actual Flow pm Minimum Flow pm K-Factor K Pressure psi C> Sprinkler 201 13.00 13.00 4.9 7.039 Sprinkler 202 13.44 13.00 4.9 7.529 r* Most Demanding Sprinkler Data L, © M.E.P.CAD, Inc. 111 AutoSPRINK 2022 v17.1.17.0 6/13/2023 1:44:41 PM Page 3 Job Name: Sunset Residence Remote Area Number: Sunset Residence R-1 Date: 6/13/2023 Supply Analysis Node Name Static (psi) Residual Flow (psi) co (gpm) Available Total Demand (psi) @ (gpm) Required Pressure (psi) 1 Water Supply 100.000 20.000 1000.00 99.904 26.44 43.471 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -3-0 Supply 43.471 26.44 201 23-0 Sprinkler 7.039 13.00 202 23-0 Sprinkler 7.529 13.44 2 -3-0 39.998 LM © M.E.P.CAD, Inc. AN AutoSPRINK 2022 07.1.17. 6/13/2023 1:44:43PM Paqe 4 Job Name: Sunset Residence Remote Area Number: Sunset Residence R-1 Date: 6/13/2023 Pipe Information Elev 1 Flow added Fittings & Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) pf Friction Elev(Pe) (q) . Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length g) ( (psi) directly to (Pf) and shown as (Foot) 201 23-0 4.9 13.00 1 (See 34-2 150 7.039 ..... Route 1 Sprinkler, 7-0 Notes) 3 23-0 13.00 1.1010 0.030666 T(5-0), 2Tr(1-0) 41-2 1.262 3 23-0 13.44 1 (See 100-11'/2 150 8.301 Flow (q) from Route 2 43-0 11.272 Notes) 2 -3-0 26.44 1.1010 0.114077 8Tr(1-0), 4cplg(1-0), 2T(5-0), 3 143-11'/2 20.425 E(7-0), BFP(-4.000) 2 3 0 2 (See 74-1'/2 150 39.998 2-0 0.003 Notes) 1 3 0 26.44 2.0030 0.006188 EE(2-0), WMV(-3.000), S 76-1'/2 3.471 0.00 43.471 Hose Allowance At Source Total(Pt) Route 1 1 26.44 202 23-0 4.9 13.44 1 (See 18-8 150 7.529 ••••• Route 2••••• Sprinkler, 5-0 Notes) 3 23-0 13.44 1.1010 0.032636 C(5-0) 23 8 0 772 8.301 Total(Pt) Route 2 & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2022 07.1.17.0 Sunset Residence R-1 6/13/2023 1:44:45PM Page 5 Job Name: Sunset Residence Remote Area Number: Sunset Residence R-1 Equivalent Pipe Lenoths of Valves and Fittinos (C=120 only) IC Value Multiplier Date: 6/13/2023 Actual Inside Diameter 4.87 I Value Of C 100 130 140 150 = Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Back -flow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90' Elbow EE 45' Elbow Eel 11'/4' Elbow Ee2 22'/2' Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 900 FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2022 07.1.17.0 Sunset Residence R-1 6/13/2023 1:44:44PM Page 6 Hydraulic Calculations for Project Name: Sunset Residence Location: 332 Sunset Ave N, Edmonds, WA 98020, 27032300100900 Drawinq Name: SUNSET FPX.XX (Homes) 2023.cad Design Remote Area Number: Remote Area Location: Occupancy Classification Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: No. of nozzles calculated: In -rack Demand: Hose Streams: Sunset Residence R-2 Sunset Residence R-2 Residential 0.050 gpm/ft2 900.00 ft2 (Actual 210.22 ft2) 256.00 ft2 Pendent 2 0 N/A gpm at Node: N/A 0.0 gpm at Node: 1 Type: Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 26.41 @ 41.021 Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent N/A Name of Contractor: NORTHWEST FIRE SYSTEMS Address: 22645 83rd Ave S. Bldg D, Kent, WA 98032 Phone Number: 253-374-8508 Name of designer: Jessica Box Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Riqht: N/A WASHINGTON STATE 1 CERTIFICATE OF COMPETENCY 1 FIRE PROTECTION SPRINKLER SYSTEMS Denise Gomez Gonzalez ; 2293-0722-B 0 1 Northwest Fire Systems, LLC �2 el NORTHFS928CR e� 1 0 0I 1 �""`- Zrrfe� Explrwa 1 1 T EEC 31, 23 1 SlgnatuEo 1 i.....................�������i Calculation Date: 6/13/2023 Allowance at Source (Safety Margin = 58.883) L© M.E.P.CAD, Inc. �JJJAutoSPRINK 2022 07.1.17.0 Sunset Residenc 6/13/2023 1:45:09PM Page 1 Job Name: Sunset Residence Remote Area Number: Sunset Residence R-2 150 135 120 105 90 N a 75 U) a� IL` 60 45 30 15 Hydraulic Graph N 1.85 Date: 6/13/2023 Water Supply Summary Sheet Node: 1 Available Static 26.41 Pressure @ Supply 100.000 99.904 26.41 @ 41.021 System demand curve 1000.00 @ 20.000 LL 800 1000 1200 1400 Flow - gpm 1600 1800 2000 & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2022 v17.1.17.0 6/13/2023 1:45:11 PM Page 2 4ilsummary Of Outflowing Devices Job Number: 01117R - Sunset Residence R-2 wo -- Keport uescripaon: Kesiaennai (sunset rtesiaence K-z) Device Actual Flow pm Minimum Flow pm K-Factor K Pressure psi Sprinkler 101 13.41 13.00 4.9 7.488 r* Sprinkler 102 13.00 13.00 4.9 7.039 r* Most Demanding Sprinkler Data L, © M.E.P.CAD, Inc. 111 AutoSPRINK 2022 v17.1.17.0 6/13/2023 1:45:12PM Page 3 Job Name: Sunset Residence Remote Area Number: Sunset Residence R-2 Date: 6/13/2023 Supply Analysis Node Name Static (psi) Residual Flow (psi) co (gpm) Available Total Demand (psi) @ (gpm) Required Pressure (psi) 1 Water Supply 100.000 20.000 1000.00 99.904 26.41 41.021 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 -3-0 Supply 41.021 26.41 101 12-6 Sprinkler 7.488 13.41 102 12-6 Sprinkler 7.039 13.00 2 -3-0 37.549 LM © M.E.P.CAD, Inc. AN AutoSPRINK 2022 07.1.17. 6/13/2023 1:45:13PM Paqe 4 Job Name: Sunset Residence Remote Area Number: Sunset Residence R-2 Date: 6/13/2023 Pipe Information Elev 1 Flow added Fittings & Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) pf Friction Elev(Pe) (q) . Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length g) ( (psi) directly to (Pf) and shown as (Foot) 102 12-6 4.9 13.00 1 (See 15-0'/2 150 7.039 ..... Route 1 Sprinkler, 15-0 -0.217 Notes) 4 13-0 13.00 1.1010 0.030666 2E(7-0), Tr(1-0) 30-0'/z 0.921 4 13-0 13.41 1 (See 111-10 150 7.743 Flow (q) from Route 2 54-0 6.936 Notes) 2 -3-0 26.41 1.1010 0.113785 4E(7-0), 3T(5-0), 7Tr(1-0), 4cp 165-10 22.869 Ig(1-0), BFP(-4.000) 2 3 0 2 (See 74-1'/z 150 37.549 2-0 0.003 Notes) 1 -3-0 26.41 2.0030 0.006172 EE(2-0), WMV(-3.000), S 76-1'/z 3.470 0.00 41.021 Hose Allowance At Source Total(Pt) Route 1 1 26.41 101 12-6 4.9 13.41 1 (See 2-6'/2 150 7.488 ••••• Route 2••••• Sprinkler, 12-0 -0.217 Notes) 4 13-0 13.41 1.1010 0.032472 E(7-0), C(5-0) 14 6% 0.472 7.743 Total(Pt) Route 2 & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2022 07.1.17.0 Sunset Residence R-2 6/13/2023 1:45:15PM Page 5 Job Name: Sunset Residence Remote Area Number: Sunset Residence R-2 Equivalent Pipe Lenoths of Valves and Fittinos (C=120 only) IC Value Multiplier Date: 6/13/2023 Actual Inside Diameter 4.87 I Value Of C 100 130 140 150 = Factor Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Back -flow Preventer BV Butterfly Valve C Cross Flow Turn 90' cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90' Elbow EE 45' Elbow Eel 11'/4' Elbow Ee2 22'/2' Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 900 FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90' Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap & © M.E.P.CAD, Inc. �jjj AutoSPRINK 2022 07.1.17.0 Sunset Residence R-2 6/13/2023 1:45:15PM Page 6