REVIEWED RESUB1 FIR2023-0042+Fire_Sprinkler_Equipment_Specification_Sheets+6.13.2023_2.33.39_PM+3606919NOR TNWES T FIRE S YS TENS 2264.E g3,d Ave. ... Bldg D * !Cent, WA 98032 Rh: 206.772.7502 * Fax: 206.772.7504 WW ,nwfire.systerns.corn LIC ##NORTHF59 8CR EQUIPMENT SUBMITTAL 332 SUNSET RESIDENCE EDMONDS, WA NWSF JOB NO. 01117R TABLE OF CONTENTS Section 1 - Pipe and Fittings Spears_CPVC Piping System Star Ductile Iron Threaded Fittings (Import) Section 2 - Hangers and Sway Bracing Argco CPVC Straps Submittal Section 3 - Valves and Accessories Ames _2000B_Backflow Double Check Assembly FPPI Ball Valve Section 5 - Fire Sprinklers Viking_Microfast_QR_SSP_K=5.6 Reliable F3QR Dry Sprinkler Viking Freedom Residential Concealed 4.9K Pendent VK494 (square cover plate) 00-002 Table Of Contents.xls Page 1 of 1 6/13/2023 SECTION 1 PIPE AND FITTINGS SPEARS FlameGuard TM CPVC FIRE SPRINKLER PIPING PRODUCTS TECHNICAL INFORMATION WEIGHTS 8 DIMENSIONS January 1, 2009 SUPERSEDES ALL PREVIOUS EDITI �101y CER�IFrr 9~ � O W z UKAS �QT a�aO I MANAGEENT 007 Qaality Systems Certificate No. 293 Corporate Facilities, Sylmar, CA Assessed To ISO 9001 : 2000 A Visit our web site �NuFACTUR�N Orr- I- 1/ �l �l,1969 ►1r 3io FG-4-0109 El FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS The information contained in this publication is based on current information and Product design at the time of publication and is subject to change without notification. Our ongoing commitment to product improvement may result in some variation. No representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular applications or results to be obtained therefrom. For verification of technical data or additional information not contained herein, please contact Spears° Technical Services Department [West Coast: (818) 364-1611—East Coast: (717) 938-9006]. General Information RECOMMENDATIONS FOR INSTALLERS AND USERS: Plastic piping systems should be ENGINEERED, INSTALLED and OPERATED in accordance with ESTABLISHED DESIGN AND ENGINEERING STANDARDS AND PROCEDURES for plastic piping systems. Suitability for the intended service application should be determined by the installer and/or user prior to installation of a plastic piping system. All Installation and maintenance personnel should be trained in the proper handling and installation requirements and precautions of plastic piping systems. PRIOR TO ASSEMBLY, all piping system components should be inspected for damage or irregularities. Mating components should be checked to assure that tolerances and engagements are compatible. Do not use any components that appear irregular or do not fit properly. Contact the appropriate manufacturer of the component product in question to determine usability. Consult all applicable codes and regulations for compliance prior to installation. Installation must be made in accordance with Spears° Manufacturing Company FlameGuardTM CPVC Fire Sprinkler Piping Products Installation Instructions - FG-3 NOTE — Individual or group instruction in correct solvent welding procedures is available by contacting your local distributor or your servicing Spears° Regional Distribution Center. SOLVENT CEMENT CONNECTIONS — Spears° Manufacturing Company recommends the use of Spears° Two Step FS-1 primer with FS-3 solvent cement OR Spears° FS-5 One Step solvent cement for joining Spears° products. Use of solvent cementing products not approved for CPVC fire sprinkler systems, or failure to follow installation instructions will automatically void the warranty. THREADED CONNECTION — Spears® Manufacturing Company recommends the use of Spears° BLUE 75Tm Thread Sealant. This product has been tested by Spears° and the sealant manufacturer for compatibility with the Spears° CPVC fire sprinkler products. Consult the sprinkler head manufacturer before using this product. WARNING: OTHER PIPE JOINT COMPOUNDS OR PASTES MAY CONTAIN SUBSTANCES THAT COULD CAUSE STRESS CRACKING IN THE CPVC OR OTHER FITTING COMPONENTS. Care must be taken to avoid over torquing - generally 1 to 2 turns beyond finger tight is all that is required to make up a threaded connection. Factory testing has indicated 10-25 ft. lbs. of torque is adequate to obtain a leak free seal. GASKET SEALED THREAD CONNECTIONS — This type of connection can only be made with Spears° TorqueSafeTM style Gasket Sealed Female Sprinkler Adapters. DO NOT USE ANY TYPE OF THREAD SEALANT WHEN INSTALLING THIS TYPE OF ADAPTER. Tape or paste may impair proper sealing and function. Testing has shown that hand tight until snug is all that is needed to seal this special connection. NOT FOR USE WITH COMPRESSED AIR OR GASES WARNING: DO NOT USE COMPRESSED AIR OR GAS TO TEST ANY PVC OR CPVC THERMOPLASTIC PIPING PRODUCT OR SYSTEM, AND DO NOT USE DEVICES PROPELLED BY COMPRESSED AIR OR GAS TO CLEAR SYSTEMS. THESE PRACTICES MAY RESULT IN EXPLOSIVE FRAGMENTATION OF SYSTEM PIPING AND COMPONENTS CAUSING SERIOUS OR FATAL BODILY INJURY. Dimension Reference G = (LAYING LENGTH) Intersection of center lines to bottom of socket/thread; 90' elbows, M = Outside diameter of socket/thread hub; ± 1/16 inch. tees, crosses; ± 1/32 inch. N = Socket bottom to socket bottom; couplings; ± 1/16 inch. H = Intersection of center lines to face of fitting; 90' elbows tees, crosses; ± 1/32 inch. Q = Width of flats; ±1/16 inch. J = Intersection of center lines to bottom of socket/thread; 45' elbows; ± 1/32 inch W = Height of cap; ± 1/16 inch. L = Overall length of fittings; ± 1/16 inch. CPVC FIRE SPRINKLER PIPE SDR 13.5 (ASTM F 442) Part Number Nominal Size Average O.D. Average I.D. Approx. Weight Lbs.IFt. Inches (mm) Inches (mm) Inches (mm) CP-007 3/4 (19.1) 1.050 (26.7) .874 (22.5) .181 CP-010 1 (25.4) 1.315 (33.4) 1.101 (28.2) .280 CP-012 1-1/4 (31.8) 1.660 (42.2) 1.394 (35.6) .418 CP-015 1-1/2 (38.1) 1.900 (48.3) 1.598 (40.7) .550 CP-020 2 (50.8) 2.375 (60.3) 2.003 (50.9) .872 CP-025 2-1/2 (63.5) 2.875 (73.0) 2.423 (61.5) 1.260 CP-030 3 (76.2) 3.500 (88.9) 2.950 (75.0) 1.900 SPEARS® MANUFACTURING COMPANY FlameGuardT"" CPVC FIRE SPRINKLER PIPING PRODUCTS El TEE Socket x Socket x Socket I I M — — I— G H L � Part Number Size G H L M Approx. Wt. (Lbs.) 4201-007 3/4 9/16 1-1/2 2-31/32 1-5/16 .11 4201-010 1 29/32 1-13/16 3-5/8 1-5/8 .19 4201-012 1-1/4 15/32 2-3/32 4-7/32 2 .29 4201-015 1-1/2 1-5/32 2-9/16 5-3/32 2-11/32 .54 4201-020 2 1-13/32 2-15/16 5-7/8 2-7/8 .79 4201-025 2-1/2 1-23/32 3-1/2 7 3-15/32 1.62 4201-030 13 2-1/16 1 3-15/16 1 7-7/8 1 4-3/16 1 3.02 REDUCING TEE Socket x Socket x Socket r--►rM1 t M � M H1 G1 G2 H r H2 L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4201-102 3/4x3/4xl 3/4 25/32 3/4 1-11/16 1-13/16 1-11/16 3-3/8 1-5/16 1-21/32 1-5/16 .13 4201-125 1x3143/4 21/32 13/16 5/8 1-25/32 1-13/16 1-5/8 3-7/16 1-17/32 1-5/16 1-5/16 .16 4201-126 lx3/4xl 3/4 1-7/8 1-3/32 1-27/32 2-31/32 1-31/32 3-13/16 1-23/32 1-23/32 1-13/32 .26 4201-131 lxlx3/4 21/32 13/16 21/32 1-25/32 1-13/16 1-25/32 3-9/16 1-5/8 1-5/16 1-5/8 .16 4201-157 1-1/4xlx3/4 11/16 1-1/32 11/16 1-15/16 2-1/32 1-13/16 3-25/32 2-3/32 1-13/32 1-23/32 .32 4201-158 1-114xlxl 27/32 29/32 25/32 2-1/16 2-1/32 1-29/32 3-15/16 1-31/32 1-5/8 1-5/8 .24 4201-159 1-1/4xlxl-1/4 31/32 31/32 31/32 1 2-7/32 2-7/32 2-3/32 4-11/32 1 2-3/32 2-3/32 1 1-23/32 .35 4201-167 1-1/41-1/43/4 21/32 1 21/32 1-29/32 2 1-29/32 3-13/16 2 1-5/16 2 .22 4201-168 1-1/41-1/41 13/16 1 13/16 2-1/16 2-1/8 2-1/16 4-1/8 1-31/32 1-5/8 1-31/32 .24 4201-169 1-1/4x1-1/4x1-112 1-1/8 15/16 1-1/8 2-3/8 2-11/32 2-3/8 4-3/4 2-3/32 2-11/32 2-3/32 .51 4201-201 1-1/2xl-114x3/4 11/16 1 1/4 2-1/16 2 1-15/16 4 2-5/16 1 1-3/8 2-1/16 .41 4201-202 1-1/2xl-114xl 27/32 1-1/32 1 1 2-7/32 2-5/32 2-1/4 4-15/32 2-5/16 1-11/16 2-1/16 .42 4201-210 1-1/2xl-1/2x3/4 23/32 1-1/16 23/32 2-3/32 2-1/32 1 2-3/32 4-3/16 2-5/16 1-3/8 2-5/16 .37 4201-211 1-1/2xl-1/2x1 1 13/16 1 1-3/16 13/16 2-3/16 2-1/4 2-3/16 4-3/8 2-11/32 1-23/32 2-11/32 .41 4201-212 1-1/2xl-1/2xl-114 1 1-1/8 1 2-3/8 2-11/32 2-3/8 4-13/16 1 2-11/32 2-3/32 2-11/32 .48 4201-213 1-1/2xl-1/2x2 1-5/16 1-1/8 1-5/16 2-11/16 2-21/32 2-11/16 1 5-3/8 1 2-11/32 1 2-27/32 2-11/32 .72 MADE IN THE U.S.A. El FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCING TEE (continued) Socket x Socket x Socket Imo-- -►r M 1 tT M I M M2 G1 G2 H -H2- L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4201-248 2x2x3/4 11/16 1-13/32 11/16 2-7/32 2-7/16 2-7/32 4-7/16 2-27/32 1-3/8 2-27/32 .52 4201-249 2x2xl 27/32 1-7/16 27/32 2-11/32 2-9/16 2-11/32 4-23/32 2-7/8 1-3/4 2-7/8 .57 4201-250 2x2xl-1/4 1 1-11/32 1 2-17/32 2-19/32 2-17/32 5-3/32 2-27/32 2-3/32 2-27/32 .63 4201-251 2x2xl-1/2 1-7/32 1-13/32 1-7/32 2-11/16 2-25/32 2-11/16 5-3/8 2-27/32 2-11/32 2-27/32 .85 4201-289 2-1/2x2-1/2xl 29/32 25/32 29/32 2-21/32 1-29/32 2-21/32 5-5/16 3-1/2 1-23/32 3-1/2 1.03 4201-290 2-1/2x2-1/2xl-1/4 1-3/32 1-23/32 1-3/32 2-27/32 1-27/32 2-27/32 5-11/16 3-1/2 2-3/32 3-1/2 1.19 4201-291 2-1/2x2-1/2xl-1/2 1-3/16 1/2 1-3/16 2-15/16 1-7/8 2-15/16 5-7/8 3-15/32 2-11/32 3-15/32 1.26 4201-292* 2-1/2x2-1/2x2 1-19/32 1 2-1/8 1-19/32 1 3-11/32 3-5/8 1 3-11/32 6-11/16 3-17/32 3-17/32 3-17/32 2.46 4201-335* 3x3xl 1-7/16 2-7116 1-7/16 3-5/16 3-23/32 3-5/16 6-5/8 4-5/32 2-7/8 4-5/32 2.00 4201-336* 30A-1/4 1-3/8 1-3/4 1-3/8 3-5/16 3-1/2 3-5/16 6-5/8 4-1/8 2-7/8 4-1/8 1.94 4201-337* 30A-1/2 1-3/8 2 1-3/8 3-5/16 3-5/8 3-5/16 6-5/8 4-1/8 2 4-1/8 1.85 4201-338 3x3x2 1 1-7/16 1-13/16 1-7/16 3-5/16 3-5/16 3-5/16 6-5/8 4-5/32 2-7/8 4-5/32 1.68 4201-339 3x3x2-1/2 1-3/4 1-31/32 1 1-3/4 3-5/8 3-23/32 1 3-5/8 1 7-1/4 4-5/32 3-7/16 4-5/32 2.08 * Branch Outlet Sized with Bushing SPRINKLER HEAD TEE Brass Thread Insert Style Socket x Socket x Fipt {�M1 1 G1 H1 M — �- M2 G G2 H -0-- H2 Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101 3/43/41/2 7/16 1-5/32 7/16 1-7/16 1-17/32 1-7/16 2-29/32 1-3/8 1-7/32 1-3/8 .27 4202-124 10/41/2 7/16 1-5/16 9/16 1-9/16 1-11116 1-9/16 3-1/8 1-11/16 1-17/32 1-3/8 .31 4202-130 1x1x1/2 7/16 1-5/16 7/16 1-9/16 1-11/16 1-9/16 3-1/8 1-23/32 1-17/32 1-23/32 .32 4202-010 1x1x1 11/16 1-3/32 1 11/16 1-13/16 1-29/32 1-13/16 3-19/32 1-23/32 1-23/32 1-23/32 .37 4202-156 1-1/41x1/2 7/16 1-15/32 9/16 1-11/16 2-1/32 1-11/16 3-3/8 2-3/32 1-7/32 1-3/4 .30 4202-166 1-1/41-1/41/2 7/16 1-9/16 7/16 1-11/16 1-15/16 1-11/16 3-3/8 2-1/16 1-17/32 2-1/16 .37 4202-199 1-1/2xl-1/41/2 1/2 1-5/8 9/16 1-7/8 2-3/16 1 1-13/16 3-11/16 2-5/16 1-7/32 2-1/16 .37 4202-209 1-1/2x1-1/2x1/2 1/2 1-23/32 1/2 1-7/8 2-3/32 1-7/8 3-3/4 2-5/16 1-17/32 2-5/16 .45 4202-237 2xl-1/2xl/2 1/2 1-7/8 17/32 2 2-7/16 1-29/32 3-15/16 2-27/32 1-7/32 2-5/16 .48 4202-247 2x2x1/2 1/2 1-31/32 1/2 2 2-3/8 2 4-1/32 2-27/32 1-17/32 2-27/32 .58 SPEARS® MANUFACTURING COMPANY FlameGuardTM CPVC FIRE SPRINKLER PIPING PRODUCTS El SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt G1 T H1 M - -t- - M - 1G G2 H H2 L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101SR 3/43/41/2 5/8 25/32 5/8 1-5/8 1-15/32 1-5/8 3-7/32 1-13/32 1-3/16 1-13/32 .16 4202-124SR 1x3/41/2 7/16 29/32 9/16 1-19/32 1-5/8 1-9/16 3-5/32 1-23/32 1-3/16 1-17/32 .19 4202-130SR 1x1x1/2 7/16 7/8 7/16 1-9/16 1-5/8 1-9/16 3-1/8 1-23/32 1-7/16 1-23/32 .25 4202-010SR 1x1x1 21/32 3/4 21/32 1-25/32 1-21/32 1-25/32 3-19/32 1-23/32 1-7/8 1-23/32 .35 4202-156SR 1-1/41x1/2 15/32 1-5/32 19/32 1-23/32 1-7/8 1-23/32 3-13132 2-3/32 1-3/16 1-23/32 .26 4202-166SR 1-1/41-1/41/2 7/16 1-1/8 7/16 1-11/16 1-27/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .26 4202-168SR 1-1/41-1/41 27/32 1-1/32 27/32 2-3/32 1-29/32 2-3/32 4-7/32 2-3/32 1-11/16 2-3/32 .34 4202-199SR 1-1/2xl-1/41/2 9/16 1-9/32 1 17/32 1-15/16 1 2 1-25/32 3-23/32 2-11/32 1-3/16 2-3/32 .33 4202-209SR 1-1/2x1-1/2x1/2 1/2 1-1/4 1/2 1-7/8 1-31/32 1-7/8 3-3/4 2-11/32 1-3/16 2-11/32 .35 4202-211SR 1-1/2xl-1/2xl 13/16 1-7/32 13/16 2-7/32 2-1/8 2-7/32 4-15132 2-11/32 1-23/32 2-11/32 .43 4202-237SR 2x1-1/2x1/2 23/32 1-9/16 3/8 2-7/32 2-9/32 1-3/4 3-31/32 2-7/8 1-3/16 2-11/32 .45 4202-247SR 2x2xl/2 1/2 31/32 1/2 2 1-11/16 1 19/32 4 1 2-7/8 1-3/16 2-7/8 48 4202-287SR 2-1/2x2-1/2xl/2 17/32 1 1-3/4 1 17/32 1 2-9/32 1 2-1/2 1 2-9/32 4-19/32 1 3-1/2 1-7/32 3-1/2 .78 SPRINKLER HEAD TEE Brass Thread Insert Style Socket x Fipt x Socket m 1 �I G1-, 1 H1 M - L G G2 �H H2 L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4203-122 lxl/2xl 9/16 25/32 1-13/32 1-9/16 1 1-27/32 1-25/32 1 3-11/32 1-5/8 1-5/8 1-17/32 .29 MADE IN THE U.S.A. 4 El FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS EMN SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x SR Fipt x Socket Part Number Size G G1 G2 H 1-11 H2 L M M1 M2 Approx. Wt. (Lbs.) 4203-122SR 1xl/2x1 27/32 3/4 1-3/32 1-23/32 1-5/8 1-13/16 3-7/16 1-23/32 1-23/32 1-7/32 1 .21 STREET TEE Spigot x Socket x Socket fM1y oD#H2- G H L1 Part Number Size G G1 G2 H H1 H2 L M1 M2 Approx. Wt. (Lbs.) 4244-007 3/4 13/16 27/32 27/32 1-13/16 1-7/8 1-7/8 3-5/8 1-13/32 1-13/32 .16 4244-010 1 1-5/32 1-1/32 1-1/32 2-1/8 1-29/32 1-29/32 4-3/16 1-3/4 1-3/4 .27 4244-012 1-1/4 1-1/4 1 1 2-7/16 2-9/32 2-9/32 4-27/32 2-3/32 2-3/32 .42 4244-015 1-1/2 1-13/16 1-1/8 1-1/8 2-7/8 2-9/16 2-9/16 5-11/32 2.11/32 2-11/32 .56 4244-020 2 1-11/16 1-7/16 1-7/16 3-1/4 2-29/32 2-29/32 6-1/8 2-27/32 2-27/32 .84 5 SPEARS® MANUFACTURING COMPANY =FlameGuardTM CPVC FIRE SPRINKLER PIPING PRODUCTS Isl 900 ELBOW Socket x Socket qr Part Number Size G H M Approx. Wt. (Lbs.) 4206-007 3/4 9/16 1-1/2 1-5/16 .07 4206-010 1 23/32 1-19/32 1-5/8 .11 4206-012 1-1/4 7/8 2-5/32 2 .21 4206-015 1-1/2 1-5/32 2-17/32 2-3/8 .41 4206-020 2 1-13/32 2-29/32 2-7/8 .45 4206-025 2-1/2 1-5/8 3-7/16 3-7/16 1.17 4206-030 1 3 1 1-29/32 1 3-23/32 4-3/16 1 1.80 SIDE OUTLET ELBOW Socket x Socket x Socket M G H Part Number Size G H M Approx. Wt. (Lbs.) 4213-007 3/4 27/32 1-19/32 1-5/16 .09 4213-010 1 3/4 1-7/8 1-5/8 .17 REDUCING 900 ELBOW Socket x Socket H1�G1 G - M1 H M Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4206-131 lx3/4 21/32 13/16 1-3/4 1-25/32 1-19/32 1-9/32 .11 MADE IN THE U.S.A. 6 El FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS SPRINKLER HEAD 900 ELBOW Brass Thread Insert Style Socket x Fipt H1,� G1- G t - - � M1 t H �I I I�M� Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101 3/41/2 7/16 1-5/32 1-23/32 1-17/32 1-13/32 1-17/32 .25 4207-130 1 x1 /2 15/32 1-5/8 1-9/16 1-11 /16 1-23/32 1-17/32 .28 4207-131 1 x3/4 1 /2 1-1/4 1-5/8 1-27132 1-23/32 1-13/32 .23 4207-166 1-1/41/2 15/32 1-17/32 1-11/16 1-15/16 2-3/32 1-17/32 .33 SPRINKLER HEAD 900 ELBOW Special Reinforced Plastic Thread Style Socket x SR Fipt H1 jGt o +1 M Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101SR 3/41/2 11/32 13/16 1-15/32 1-1/2 1-13/32 1-3/16 .14 4207-130SR 1x1/2 7/16 7/8 1-9/16 1-5/8 1-23/32 1-3/8 .20 4207-131SR 1x3/4 1/2 7/8 1-5/8 1-9/16 1-23/32 1-3/8 .16 4207-166SR 1-1/41/2 13/32 1-1/32 1-21/32 1-23/32 2-3/32 1-7/32 .19 SPEARS® MANUFACTURING COMPANY FlameGuardTM CPVC FIRE SPRINKLER PIPING PRODUCTS El 900 STREET ELBOW Spigot x Socket H1�G1 G M1 H I.--►� PIPE O.D. Part Number Size G G1 H H1 M1 Approx. Wt. (Lbs.) 4209-007 3/4 15/16 17/32 1-15/16 1-17/32 1-3/8 .12 4209-010 1 1-9/32 23/32 2-13/32 1-27/32 1-3/4 .21 4209-012 1-1/4 1-9/16 27/32 2-13/16 2-3/32 2-3/32 .32 4209-015 1-112 1-15/32 1-3/16 2-27/32 2-9/16 2-11/32 .42 4209-020 2 1-23/32 1-3/8 3-7/32 2-15/16 2-27/32 .65 22-1/20 ELBOW Socket x Socket J 1 i Part Number Size H J M Approx. Wt. (Lbs.) 4216-007 3/4 1-3/16 7/32 1-13/32 .09 4216-010 1 1-3/8 9/32 1-25/32 .14 4216-012 1-1/4 1-1/2 5/16 2-3/32 .20 4216-015 1-1/2 1-7/16 13/32 1-3/8 .19 4216-020 2 1-7/8 3/8 2-27/32 .43 4216-030 3 2-3/8 1 /2 4-5/32 1.00 MADE IN THE U.S.A. El FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS 22-1/20 STREET ELBOW Spigot x Socket 1� H1 A M1 �. H j I�►�PIPE O.D. Part Number Size H H1 J J1 M1 Approx. Wt. (Lbs.) 4242-007 3/4 1-1/4 1-1/2 1/4 1/2 1-3/8 .08 4242-010 1 1-7/16 1-11/32 5/16 7/32 1-23/32 .14 4242-012 1-1/4 1-9/16 1-25/32 17/32 11/16 2-1/16 .21 4242-015 1-1/2 1-13/32 1-23/32 1/2 11/32 2-11132 .28 4242-020 2 1-29/32 2-1/8 7/32 5/8 2-7/8 .42 4242-025 2-1/2 2-1/8 2-1/4 13/32 1/2 3-1/2 .68 4242-030 3 2-13/32 2-13/32 9/16 17/32 4-5/32 .99 450 ELBOW Socket x Socket I H Part Number Size H J M Approx. Wt. (Lbs.) 4217-007 314 1-5/16 5/16 1-5/16 .10 4217-010 1 1-15/32 11 /32 1-5/8 .11 4217-012 1-1/4 1-5/8 3/8 2-5/32 .21 4217-015 1-1/2 1-27/32 15/32 2-11/32 .32 4217-020 2 2-1/8 21 /32 2-7/8 .48 4217-025 2-1/2 2-1/2 3/4 3-1/2 .96 4217-030 3 2-3/4 7/8 4-5/32 1.22 SPEARS® MANUFACTURING COMPANY FlameGuardTM CPVC FIRE SPRINKLER PIPING PRODUCTS El 450 STREET ELBOW Spigot x Socket H1�� J1 M1 1 H IPIPE O.D. Part Number Size H H1 J J1 M1 Approx. Wt. (Lbs.) 4227-010 1 1-1/2 1-5/16 1/2 1/4 1-5/8 .10 4227-012 1-1/4 1-25/32 1-9/16 9/16 11/32 1-31/32 .15 4227-015 1-1/2 2-1/32 2-1/8 19/32 25/32 2-11/32 .29 4227-020 2 2-5/16 1-15/16 25/32 13/32 2-7/8 .44 CROSS Socket x Socket x Socket x Socket _ G11 I f ! T - L1 H LIGI-I► H L� Part Number Size G G1 H H1 L L1 M Approx. Wt. (Lbs.) 4220-007 3/4 5/8 5/8 1-21/32 1-21/32 3-5/16 3-5/16 1-13/32 .22 4220-010 1 3/4 3/4 1-5/8 1-5/8 3-1/4 3-1/4 1-23/32 .20 4220-012 1-1/4 1-1/8 1-1/8 2-3/8 2-3/8 4-3/4 4-3/4 2-3/32 .63 4220-015 1-1/2 1-7/32 1-7/32 2-5/8 2-5/8 1 5-1/4 5-1/4 2-11/32 1 .80 4220-020 2 1-1/2 1-1/2 3 3 6 6 3 1.43 4220-025 2-1/2 1-23/32 1-23/32 3-13/32 3-13/32 6-13/16 6-13/16 3-1/2 2.11 4220-030 3 2-3/32 2-3132 1 3-31/32 3-31/32 7-15/16 7-15/16 4-7/16 3.37 MADE IN THE U.S.A. 10 El FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCING CROSS Socket x Socket x Socket x Socket M- H1 - - - -- - L1 G1 LG!J� � H L Part Number Size G G1 H H1 L L1 M M1 Approx. Wt. (Lbs.) 4220-131 1x3/4 7/8 5/8 2 1-5/8 4 3-1/4 1-27/32 1-1/2 .35 4220-167 1-1/43/4 1-1/16 23/32 2-1/16 1-31/32 4-3/32 3-31/32 2-1/16 1-13/32 .35 4220-289 2-1/2xl 29/32 1-3/4 2-11/16 2-7/8 5-11/32 5-3/4 3-1/2 1-3/4 .98 COUPLING Socket x Socket N1 L I M � Part Number Size L M N Approx. Wt. (Lbs.) 4229-007 3/4 2-1/8 1-5/16 3/16 .05 4229-010 1 2-3/16 1-5/8 3/32 .08 4229-012 1-1/4 2-19/32 2 3/32 .13 4229-015 1-1/2 2-7/8 2-11 /32 3/32 .22 4229-020 2 3-1/8 2-7/8 1 /8 .33 4229-025 2-1/2 3-11/16 3-15/32 3/16 .48 4229-030 3 4 4-3/16 1 /4 .89 SPEARS® MANUFACTURING COMPANY FlameGuardTM CPVC FIRE SPRINKLER PIPING PRODUCTS El REDUCER COUPLING Socket x Socket M ---- -- M1 L N L Part Number Size L M M1 N Approx. Wt. (Lbs.) 4229-131 1x3/4 2-3/8 1-23/32 1-13/32 7/32 .10 4229-167 1-1/43/4 2-19/32 2-3/32 1-5/8 11/32 .17 4229-168 1-1/4xl 2-11/16 2-3/32 1-23/32 5/16 .18 4229-210 1-1/20/4 2-13/16 2-11/32 1-13/32 15/32 .19 4229-211 1-1/2xl 2-7/8 2-11/32 1-15/16 3/8 .24 4229-212 1-1/2xl-1/4 2-25132 2-3/8 2-3/32 5/32 .22 4229-248 2x3/4 3-3/16 2-7/8 1-7/16 23/32 .32 4229-249 2xl 3-1/8 2-7/8 1-23/32 1/2 .31 4229-250 2xl-1/4 3-3/16 2-7/8 2-1/8 17/32 .33 4229-251 2xl-1/2 3-3/16 2-27/32 2-11/32 9/32 .31 4229-291 2-1/2xl-1/2 3-23/32 3-15/32 2-11/32 21/32 .51 4229-292 2-1/2x2 3-21/32 3-1/2 2-7/8 13/32 .52 GROOVED COUPLING ADAPTER Groove x Socket PIPE - _ - _ - _ M1 O.D. L 1 Part Number Size L M1 N Approx. Wt. (Lbs.) 4233-012 1-1/4 3-5/8 2-3/32 2-11/32 .72 4233-015 1-1/2 3-3/4 2-11/32 2-11/32 .83 4233-020 2 3-27/32 1 2-27/32 1 2-11/32 1.27 4233-025 2-1/2 3-3/8 3-1/2 1-21 /32 .52 4233-030 3 3-9/16 4-5/32 1-23/32 .72 MADE IN THE U.S.A. 12 El FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE ADAPTER Brass Thread Insert Style Socket x Fipt M L M1 N Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-007 3/4 2 1-13/32 1-3/8 5/16 .23 4235-010 1 2-9/32 1-3/4 1-29/32 13/32 .38 4235-012 1-1/4 2-3/8 2-3/32 2-1/16 13/32 .35 4235-015 1-1/2 2-9/16 2-3/8 2-7/16 7/16 .47 4235-020 2 2-11/16 2-7/8 3-1/32 15/32 1.14 FEMALE ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt I M M1 L 1 N - L Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-007SR 3/4 1-7/8 1-13/32 1-3/8 1/8 .09 4235-010SR 1 2-5/32 1-23/32 1-7/8 3/32 .22 4235-012SR 11-1/4 1 2-5/16 1 2-1/8 1 2-1/16 13/16 .20 13 SPEARS® MANUFACTURING COMPANY FlameGuardT"" CPVC FIRE SPRINKLER PIPING PRODUCTS El FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt M I M1 N L Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101SR 3/41/2 1-13/16 1-13/32 1-3/8 3/32 .12 4235-130SR 1x1/2 1-31/32 1-23/32 1-3/8 3/32 .16 4235-131SR 1x3/4 2-3/32 1-3/4 1-3/8 1/4 .13 FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Socket Wrench Flats Socket x SR Fipt M ———— —— M1 M = Flat -to -Flat Dimension N L� Part Number Size L M M1 N Approx. Wt. W4235-101SR I 3/4x1/2 2-9/32 1-13/32 1-3/16 17/32 I .09 W4235-130SR I 1x1/2 2-9/32 1-3/4 1-3/16 13/32 .12 MADE IN THE U.S.A. 14 El FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread w/Metal Thread Start Socket x SR Fipt I M - -- --- I M1 N- F L Part Number Size L M M1 N Approx. Wt. (Lbs.) Z4235-101SIR 3/41/2 1-7/8 1-3/8 1-7/16 3/16 .08 Z4235-130SR 1x1/2 2-1/32 1-23/32 1-7/16 5/32 .17 SPIGOT FEMALE ADAPTER Brass Thread Insert Style Spigot x Fipt PIPE O.D. M1 i �f-► L� ItN Part Number Size L M1 N Approx. Wt. (Lbs.) 4278-007 3/4 2-1/32 1-3/8 15/32 .14 4278-010 1 2-15/32 1-23/32 9/16 .27 SPIGOT FEMALE ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt 1 1 PIPE M1 o.D. � 11 N- • L� Part Number Size L M1 N Approx. Wt. (Lbs.) 4278-007SR 3/4 1-15/16 1-3/8 11/32 .08 4278-010SR 1 2-1/4 1-23/32 13/32 .13 15 SPEARS" MANUFACTURING COMPANY FlameGuard"' CPVC FIRE SPRINKLER PIPING PRODUCTS El GASKET SEALED FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Socket x Gasket Fipt I M - — -— - M1 N — L� Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-130GS 1 x1 /2 2 1-11 /16 1-17/32 1 /2 .21 FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Socket x Fipt I M M1 FN LH Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101 3/4xl /2 1-7/8 1-13/32 1-17/32 15/32 .19 4235-130 1 x1 /2 2-5/32 1-11 /16 1-3/16 19/32 .16 4235-131 1 x3/4 2 1-11 /16 1-9/16 19/32 .18 FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style with Long Body Socket x Fipt I M L Part Number Size L M M1 N Approx. Wt. L4235-130 1 x1 /2 2-3/16 1-23/32 1-7/32 1 /2 .19 MADE IN THE U.S.A. 16 El FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style with Positioning Ring Socket x Fipt M M1 j, L� Part Number Size L M M1 N Approx. Wt. (Lbs.) R4235-101 3/41/2 2-1/32 1-7116 1-3/16 15/32 .15 FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Positioning Ring Socket x SR Fipt I M M1 N L� Part Number Size L M M1 N Approx. Wt. (Lbs.) R4235-101SIR 3/41/2 1-15/16 1-7/16 1-7/32 7/32 .09 SPIGOT FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Spigot x Fipt PIPE O.D. M1 N �« L ' Part Number Size L M1 N Approx. Wt. (Lbs.) 4238-101 3/4x1 /2 1-15/16 1-17/32 17/32 .18 4238-130 1 x1 /2 2-1/4 1-3/16 11 /32 .19 17 SPEARS" MANUFACTURING COMPANY FlameGuardTM CPVC FIRE SPRINKLER PIPING PRODUCTS BUSHING with BRASS THREAD INSERT Spigot x Fipt I _ PIPE O.D. 1 El Part Number Size L Approx. Wt. Lbs. 4238-130BR 1 x1 /2 1 .13 SPIGOT FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt 11 PIPE O.D. N� �L� Part Number Size L M1 N Approx. Wt. Lbs. 4238-101SR 3/41/2 1-29/32 1-7/32 1/8 .07 4238-130SR 1x1/2 2-1/32 1-7132 7/32 .09 MALE ADAPTER With CPVC Lined Thread Brass Insert Mipt x Socket - — - — — - — M1 1 �► N L� Part Number Size L M1 N Approx. Wt. (Lbs.) 4236-007 3/4 2-17/32 1-13/32 13/16 .15 4236-010 1 2-15/16 1-23/32 29/32 .30 4236-012 1-1/4 3-1/8 2-3/32 31/32 .50 4236-015 1-1/2 3-9/32 2-11/32 31/32 .80 4236-020 12 13-7/16 12-7/8 1 31/32 11.00 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Q Socket x SR Fipt I N Body �L Width Part Number Size L N Q Body Width Approx. Wt. (Lbs.) Min Max Min Max 42001SR 3/41/2 6-9/32 8 4-7/16 6-1/4 1-7/16 2-3/16 .66 42011SR 1x1/2 6-13/32 8 4-1/2 6-1/8 1-7/16 2-1/8 .68 MADE IN THE U.S.A. 18 El FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt PIPE 0 L.D. Body L Width L N Part Number Size Q Body Width Approx. Wt. (Lbs.) Min Max Min Max 42004SR 3/41/2 5-1/32 6-5/16 3-3/16 4-15/32 1-5/16 2-1/8 .36 42014SR 1x1/2 6-7/16 8-1/8 4-7/16 6-1/4 1-7/16 2-3/16 .67 REDUCER BUSHING Flush Style Spigot x Socket PIPE O.D. L N L Part Number Size L N Approx. Wt. (Lbs.) 4237-131 1 x3/4 1-1/4 1 /4 .04 4237-167 1-1/43/4 1-19/32 17132 .12 4237-168 1-1 /4x1 1-13/32 9/32 .06 4237-210 1-1/2x3/4 1-11/16 11/16 .19 4237-211 1-1/2xl 1-17/32 13/32 .15 4237-212 1-1/2xl-1/4 1-9/16 5/16 .07 4237-248 2x3/4 1-29/32 29/32 .27 4237-249 2x1 1-29/32 3/4 .25 4237-250 2x1-1/4 1-11/16 7/16 .21 4237-251 2x1-1 /2 1-11 /16 5/16 .15 4237-290 2-1/2xl-1/4 2-13/32 1-5/32 .45 4237-291 2-1/2xl-1/2 2-13/32 1-1/32 .43 4237-292 2-1 /2x2 2-9/32 25/32 .29 4237-338 3x2 2-1/4 3/4 .63 4237-339 3x2-1 /2 2-5/16 1 /4 .40 19 SPEARS® MANUFACTURING COMPANY FlameGuardTM CPVC FIRE SPRINKLER PIPING PRODUCTS El CAP Socket M W Part Number Size M W Approx. Wt. (Lbs.) 4247-007 3/4 1-3/8 1-13/32 .05 4247-010 1 1-5/8 1-19/32 .06 4247-012 1-1/4 2-3/32 1-27/32 .13 4247-015 1-1/2 2-11/32 2 .17 4247-020 2 2-27/32 2-9/32 .39 4247-025 2-1/2 3-17/32 2-11 /16 .48 4247-030 3 4-3/8 3 .92 TEST PLUG - 0-ring Sealed Mipt - For Pressure Testing Only, Not For use with Z4235 Series Adapters L� M1 F — - — -— M I L�-lr 11 1/2 14 NPT Part Number Size L M M1 Approx. Wt. (Lbs.) FTP-005 1 /2 1-27/32 1-15/16 1-7/32 .03 TEST PLUG for TorqueSafeTrI Gasket Sealed Head Adapters Mipt - For Pressure Testing Only. Use ONLY with Gasket Sealed Head Adapters L= M1 M I Lg�` -T 11 1/2 14 NPT Part Number Size L M M1 Approx. Wt. (Lbs.) FTP-005GS 1 /2 1-25/32 2-1 /32 1-1/4 .05 MADE IN THE U.S.A. 20 El FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS TEST PLUG (PVC White) Not UL Listed; For Pressure Testing Only, Mipt Part Number Size L Approx. Wt. Lbs. 4250-005 1/2 27/32 .02 FLANGE - ONE PIECE 4 Bolt Holes, 175 psi Socket If- M L F-R 2 N If BOLT CIRCLE DIA. �I �- MAX O.D. No. of Bolt Min. Bolt Max. Approx. Wt. Part Number Size L M N R Bolt Circle Bolt Size O.D. (Lbs.) Holes Dia. Len th 4251-007 3/4 1-5/32 1-1/2 1/8 17/32 4 2-3/4 1/2 2 3-29/32 .31 4251-010 1 1-5/16 1-13/16 1/8 11/16 4 3-1/8 1/2 2-1/4 4-9/32 .35 4251-012 1-1/4 1-13/32 2-7/32 5/32 11/16 4 3-1/2 1/2 2-1/4 4-5/8 .44 4251-015 1-1/2 1-9/16 2-1/2 3/16 23/32 4 3-7/8 1/2 2-1/2 5 .52 4251-020 2 1-27/32 3 11/32 7/8 4 4-3/4 5/8 3 5-31/32 .95 4251-025 2-1/2 2-1/4 3-1/2 1/2 1-1/32 4 5-1/2 5/8 3-1/4 6-15/16 1.57 BLIND FLANGE 4 Bolt Holes, 175 psi LR 2 I� BOLT CIRCLEDIA. O.D. Bolt No. of Bolt Min. Bolt Part Number Size R Bolt Size Max. O.D. Approx. Wt. (Lbs.) Circle Dia. Holes Length 4253-007 3/4 17/32 2-3/4 4 1/2 2 3-27132 .30 4253-010 1 23/32 3-1/8 4 1/2 2-1/4 4-1/4 .35 4253-012 1-1/4 21/32 3-1/2 4 1/2 2-1/4 4-5/8 .40 4253-015 1-1/2 3/4 3-7/8 4 1/2 2-1/2 5-1/32 .74 4253-020 2 25/32 4-3/4 4 5/8 3 5-15/16 .89 4253-025 2-1/2 1-1132 5-1/2 4 5/8 3-1/4 6-15/16 1.70 4253-030 1 3 1 1-5/16 1 6 1 4 1 5/8 1 3-1/4 1 7-5/8 1 1.72 21 SPEARS® MANUFACTURING COMPANY FlameGuardTM CPVC FIRE SPRINKLER PIPING PRODUCTS FLANGE - TWO PIECE Van Stone Style, 4 Bolt Holes, 175 psi Socket M NJ BOLT CIRCLE DIA.—I -- MAX O.D. -� Bolt Circle No. of Bolt Min. Bolt Part Number Size L M N R Dia. Holes Bolt Size Length Max. O.D. Approx. Wt. (Lbs.) 4254-030 3 1 2-1/8 1 4-1/4 1 9/32 1 1-1/32 1 6 4 1 5/8 1 3-1/4 1 7-15/32 1 1.75 FLANGE - TWO PIECE Van Stone Style, 4 Bolt Holes, 175 psi Spigot PIPE O.D. N L 1DIA7—Di R a�BOLT CIRCLE MAX O.D. Bolt No. of Bolt Min. Bolt Max. Part Number Size L N R Circle Bolt Approx. Wt. (Lbs.) Size Length O.D. Dia. Holes 4256-007 3/4 1-15/16 13/16 17/32 2-3/4 4 1/2 2 3-27/32 .30 4256-010 1 1 2-7/32 1-1/32 11/16 1 3-1/8 4 1/2 1 2-1/4 4-1/4 .41 4256-012 1-1/4 2-3/8 1 11/16 3-1/2 4 1/2 2-1/4 4-5/8 .50 4256-015 1-112 2-7/16 1-3/32 23/32 3-7/8 4 1/2 2-1/2 4-31/32 .65 4256-020 2 2-3/4 1-5/32 25/32 4-3/4 4 5/8 3 5-15/16 1.00 4256-025 2-1/2 3-1/16 1-9/32 1-1/32 5-1/2 4 5/8 3-1/4 6-15/16 1.62 4256-030 3 1 3-3/8 1 1-13/32 1 1-1/32 1 6 4 5/8 1 3-1/4 1 7-9/16 1.76 UNION Socket x Socket NUT M O.D. N L �I Part Number Size L M N Nut O.D. Approx. Wt. (Lbs.) 4257-007 3/4 2-3/8 1-17/32 3/8 2-1/2 .38 4257-010 1 2-9/16 1-27/32 3/8 2-7/8 .41 4257-012 1-1/4 2-27/32 2-7/32 11/32 3-5/16 .52 4257-015 1-1/2 3-1/8 2-1/2 3/8 3-17/32 .63 4257-020 2 3-5/8 3-1/32 9/16 4-3/16 1.09 MADE IN THE U.S.A. 22 El FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS TRANSITION UNION Brass Thread Insert Style Socket x Fipt I NUT O.D. N L Part Number Size L M N Nut O.D. Approx. Wt. (Lbs.) 4259-010BR 1 2-7/8 1-27132 1 2-7/8 .56 4259-012BR 1-1/4 3 2-3/16 1-1/8 3-9/32 .98 4259-015BR 1-1/2 3-3/4 2-1/2 1-9/16 3-17/32 .93 4259-020BR 2 4-3/16 3-1/32 1-27/32 4-3/16 1.57 SOCKET DIMENSIONS SCH 40 - ASTM F438 SCH 80 - ASTM F439 I-.*- C B IA i Socket Socket SCH 40 Minimum SCH 80 Minimum Size Tolerance Entrance A Bottom B Socket Length C Socket Length C 3/4 1.058 1.046 ± 0.004 0.719 1.000 1 1.325 1.130 ± 0.005 0.875 1.125 1-1/4 1.670 1.655 ± 0.005 0.938 1.250 1-1/2 1.912 1.894 ± 0.006 1.094 1.375 2 2.387 2.369 ± 0.005 1.156 1.500 2-1/2 12.889 12.868 1 ± 0.007 11.750 11.750 3 13.516 13.492 1± 0.008 11.875 11.875 23 SPEARS® MANUFACTURING COMPANY NOTES NOTES NOTES NOTES NOTES NOTES NOTES SPEARS° MANUFACTURING COMPANY Corporate Office SPEARS 15853 Olden Street • Sylmar, CA 91342 PO Box 9203 • Sylmar, CA 91392 (818) 364-1611 • http://www.spearsmfg.com X,t� THE M W © Copyright 2009 Spears® Manufacturing Company. All Rights Reserved. Printed in the United States of America 01/09. FG-4-0109 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3201 90' Elbow FIGURE 3201 900 ELBOW Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 11/4 500 1.75 0.90 32 3450 44.45 0.41 1 /2 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 50 1 3450 57.15 1 0.84 — Working Pressure Ratings are for reference only and based on Sch. AO pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 -us <S> STED APPROVED Approval Details and Limitations, vebsite at www.anvlllntlxom or n Anvi10 Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3207 R Reducing Cross BB I 1 I A I 2 2 I I A 1 t 1 x 1 x 2 x 2 FIGURE • REDUCING CROSS Nominal Size Max. Working Pressured Dimensions Approx. Wt. Each 1 x 1 x 2 x 2 A 8 In. hin) PSI (kPo) In. (mm) In. (mm) Lbs. (kg) 1Ax1Ax1 xl 32 x 32 x 25 x 25 500 3450 1.58 40.13 1.67 42.41 1.27 0.58 1 l/2 x 1 th x 1 x 1 40 x 40 x 25 x 25 500 1 3450 1.65 1 41.91 1.80 1 45.12 1.48 1 0.67 2 x 2 x I x 1 50 x 50 x 25 x 25 500 3450 1.73 43.94 2.02 51.30 2.10 0.95 — Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 LISTED APPROVED tings/Approval Details and Limitations, our website at www.anvilintlxom or act an Anvils Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3283 Bushings F_t �B IA M- Inside Head C � F- I� B I �A M- Outside Head FIGURE 3283 - BUSHINGS Nominal Size Max. Working Pressured Dimensions Style Approx. Wt. Each Male (M) x Female (F) A g ( In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) L6s. (kg) 1 x I/2 500 0.75 0.25 1.42 Outside 0.22 25 x 15 3450 19.05 6.35 36.06 0.10 Oluftide Headoo 0.75 0.25 1.42 Outside 0.17 25 x 20 3450 19.05 6.35 36.06 0.08 11/a x 1 500 0.80 0.28 1.76 Outside 0.28 32 x 25 3450 20.32 7.11 44.70 0.13 11/z x 1 500 0.83 0.31 2.00 Outside 0.45 40 x 25 3450 21.08 7.874 50.80 0.20 11/2 x 11/a 500 0.83 0.31 2.00 Outside 0.30 40 x 32 3450 21.08 7.874 50.80 0.14 2 x 1 500 0.88 0.41 1.95 Inside 0.67 50 x 25 3450 22.35 10.414 49.53 0.30 2 x 11/a 500 0.88 0.34 2.48 Outside 0.73 50 x 3 1 3450 1 22.35 1 8.636 1 62.99 1 1 0.33 2 x 11/2 500 0.88 0.34 2.48 Outside 0.61 50 x 40 3450 22.35 8.636 62.99 0.28 - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.14 LISTED APPROVED Listings/Approval Details and Limitations, iisit our website at www.anvilintl.com or lontact an Anvil" Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3224 Cap A FIGURE 3224 - CAP Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure. In. (Tim) PSI (kPa) In. (Tim) Lbs. (kg) 1 500 1.16 0.32 25 3450 29.46 0.15 1l/4 500 1.28 0.43 32 3450 32.51 0.20 ll/2 500 1.33 0.60 40 3450 33.78 0.27 2 500 1.45 0.91 50 1 3450 1 36.83 1 0.41 — Working Pressure Ratings are for reference only and based on Sch. AO pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 C UL us FM LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvlllntlxom or contact an Anvi10 Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3207 Cross FIGURE Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure In. (Tim) PSI (kPa) In. (Tim) Lbs. (kg) 1 500 1.50 0.98 25 3450 38.10 0.44 11/4 500 1.75 1.50 32 3450 44.45 0.68 11/2 500 1.94 1.90 40 3450 49.27 0.86 2 500 2.25 2.95 50 1 3450 1 57.15 1 1.34 — Working Pressure Ratings are for reference only and based on Sch. AO pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 LISTED APPROVED tings/Approval Details and Limitations, our website at www.anvilintlxom or act an Anvi10 Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3201R Reducing 90' Elbow 2 1 1x2 FIGURE 3201R - REDUCING I 0 ELBOW Nominal Size Max. Working Pressured Dimensions Approx. Wt. Each 1 x 2 A g In. (mm) PSI (kPa) In. (mm) In. (mm) Lbs. (kg) 1 x /2 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.20 1 x 3/4 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 1 t/4 x I/2 500 1.34 1.53 0.64 32 x 15 34550 34.03 38.86 0.29 11/4 x 3/4 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 11/4 x 1 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 11/2 x 1 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 1 I/2 x 11/4 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.49 2 x 1/2 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 1/4 500 1.60 1.97 1.24 50 x 20 3450 40.64 50.03 0.56 2 x 1 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11/4 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11/2 500 2.02 2.16 1.65 50 x 40 1 3450 1 51.30 1 54.86 1 0.75 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit onvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 /UR us <S> ISTED APPROVED /Approval Details and Limitations, website at www.anvilintl.com or in Anvil", Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/131I-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3221R Reducing Coupling Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressure In. (Tim) PSI (kPa) In. (Tim) Lbs. (kg) 1 x /2 500 1.69 0.39 25 x 15 3450 42.92 0.18 1 x 3/4 500 1.69 0.53 25 x 20 3450 42.92 0.24 — Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 C UL us FM LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.anvilintlxom or contact an Anvi10 Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3205R Reducing Tee 2 3 1 1 x 2 x 3 FIGURE IREDUCING Nominal Size Max. Working Dimensions Approx. Wt. Each l x 2 x 3 Pressured A B In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x l/z x 1 500 1.50 1.36 1.50 0.64 25 x 15 x 25 3450 38.10 34.54 38.10 0.29 1 x 3/4 x 1 500 1.50 1.45 1.50 0.73 25 x 20 x 25 3450 38.10 36.83 38.10 0.33 1 x 1 x l/2 500 1.26 1.26 1.36 0.71 25 x 25 x 15 3450 32.00 32.00 34.54 0.32 1 x 1 x 3/4 500 1.37 1.37 1.45 0.76 250500 3450 34.80 34.80 36.83 0.34 1 x 1 x 1 t/4* 500 1.67 1.67 1.58 0.98 25 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 1 x 1 t/z* 500 1.80 1.80 1.65 1.16 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 1 l'A x 1 x t/z* 500 1.34 1.26 1.53 0.82 32 x 25 x 15 3450 34.04 32.00 38.86 0.37 1 t/4 X 1 X 3/4 500 1.45 1.37 1.62 0.90 32 x 25 x 20 3450 36.83 34.80 41.15 0.41 1l/4 x 1 x 1 500 1.58 1.50 1.67 1.00 32 x 25 x 25 3450 40.13 38.10 42.42 0.45 1l/4 x 1 x 1 l/4 500 1.75 1.67 1.75 1.08 32 x 25 x 32 3450 44.45 42.42 44.45 0.49 1l/4 x 1 x 1l/2 500 1.88 1.80 1.82 1.42 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 1 l/4 x 1 l'A x l/2 500 1.34 1.34 1.53 0.86 32 x 32 x 15 3450 1 34.04 34.04 38.86 1 0.39 Dimensions: ASME B16.3 LISTED APPROVED Itings/Approval Details and Limitations, our website at www.anvilintlxom or tact an Anvils Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. FIGURE 3205R - REDUCING TEE Nominal Size Max. Working PressureA Dimensions Approx. Wt. Each l x 2 x 3 A 7 B PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 t/4 X 1l/4 X 3/4 32 x 32 x 20 500 3450 1.45 1 36.83 1.45 36.83 1.62 41.15 0.92 0.42 1l/4 x 1l/4 x 1 32 x 32 x 25 500 3450 1.58 40.13 1.58 40.13 1.67 42.42 0.95 0.43 1 l/4 x 1 l'A x 1 t/z* 32 x 32 x 40 500 3450 1.88 47.75 1.88 1 47.75 1.82 46.22 1.45 0.66 Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit onvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3205R Reducing Tee T ' 2 B' ' 3 T ' A 1 1 x 2 x 3 FIGURE 3205R - REDUCING TEE Nominal Size Max. Working Dimensions Approx. Wt. Each 1 x 2 x 3 Pressured A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11/4 x 11/4 x 2* 500 2.10 2.10 1.90 1.75 32 x 32 x 50 3450 53.34 53.34 48.26 0.79 11/2 x 1 x /2 500 1.41 1.34 1.66 0.95 40 x 25 x 15 3450 35.81 34.04 42.16 0.43 1 V2 x 1 x 3/4 500 1.52 1.37 1.75 1.14 40 x 25 x 20 3450 38.61 34.80 44.45 0.52 11/2 x 1 x 1 500 1.65 1.50 1.80 1.17 40 x 25 x 25 3450 41.91 38.10 45.72 0.53 1 /2 x 1 x 11/4 500 1.82 1.67 1.88 1.34 40 x 25 x 32 3450 46.23 42.42 47.75 0.61 11/2 x 1 x 11/2 500 1.94 1.80 1.94 1.45 40 x 25 x 40 3450 49.28 45.72 49.28 0.66 1 '/2 xl b x /2 500 1.41 1.34 1.66 1.05 40 x 32 x 15 3450 35.81 34.04 42.16 0.48 11/2 xl'A x 3/4 500 1.52 1.45 1.75 1.15 40 x 32 x 20 3450 38.61 36.83 44.45 0.5 1 /2 x 1 /4 x 1 500 1.65 1.58 1.80 1.25 40 x 32 x 25 3450 41.91 40.13 45.72 0.57 1/2x1/4x2* 500 2.16 2.10 2.02 1.90 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 P/2x1/2XV2 500 1.41 1.41 1.16 1.15 40 x 40 x 15 3450 35.81 35.81 29.46 0.52 1 '/2 X 1 �/2 X 3/4 500 1.52 1.52 1.75 1.24 40 x 40 x 20 3450 38.61 38.61 44.45 0.56 1'/2 x 11/2 x 1 500 1.65 1.65 1.80 1.30 40 x 40 x 25 3450 41.91 41.91 45.12 0.59 11/2 x 11/2 x 1 �/4 500 1.82 1.82 1.88 1.48 40 x 40 x 32 3450 46.23 46.23 47.75 0.67 FIGURE 3205R - REDUCING TEE Nominal Size Max. Working Dimensions Approx. Wt. Each 1 x 2 x 3 Pressured A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11/2 x 11/2 x 2* 500 2.16 2.16 2.02 1.98 40 x 40 x 50 3450 54.86 54.86 51.30 0.90 2 x 1 x 2 500 2.25 2.02 2.25 2.15 50 x 25 x 50 3450 57.15 51.31 57.15 0.98 2 x 1'/4 x 2 500 2.25 2.10 2.25 2.30 50 x 32 x 50 3450 57.15 53.34 57.15 1.04 2 x 11/2 x 1/2 500 1.49 1.41 1.88 1.50 50 x 40 x 15 3450 37.85 35.81 47.75 0.68 2 x 11/2 X 1/4 500 1.60 1.52 1.97 1.62 50 x 40 x 20 3450 40.64 38.61 50.04 0.73 2 x 11/2 x 1 500 1.73 1.65 2.02 1.64 50 x 40 x 25 3450 43.94 41.91 51.31 0.74 2 x 11/2 x 11/4 500 1.90 1.82 2.10 1.80 50 x 40 x 32 3450 48.76 46.23 53.34 0.82 2 x 11/2 x 11/2 500 2.02 1.94 2.16 2.00 50 x 40 x 40 3450 51.31 49.28 54.86 0.91 2 x 11/2 x 2 500 2.25 2.16 2.25 2.35 50 x 40 x 50 3450 57.15 54.86 57.15 1.07 2 x 2 x 1/2 500 1.49 1.49 1.88 1.60 50 x 50 x 15 3450 37.85 37.85 47.75 0.73 2 x 2 x 1/4 500 1.60 1.60 1.97 1.68 50 x 50 x 20 3450 40.64 40.64 50.04 0.76 2 x 2 x 1 500 1.73 1.73 2.02 1.85 50 x 50 x 25 3450 43.94 43.94 51.31 0.84 2 x 2 x 11/4 500 1.90 1.90 2.10 2.04 50 x 50 x 32 3450 44.45 42.42 44.45 0.93 2x2x1/2 500 2.02 2.02 2.16 2.18 50 x 50 x 40 3450 44.45 42.42 44.45 0.99 ♦ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". SPF/DI-1.15 SPF/RNVIL° DUCTILE IRON THREADED FITTINGS Z /ANVIL FIG. 3205 Straight Tee A I I I I I STRAIGHT Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressurek In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.50 0.85 25 3450 38.10 0.39 1 A 500 1.75 1.22 32 3450 44.45 0.55 1 /z 500 1.94 1.55 40 3450 49.27 0.70 2 500 2.25 2.45 50 1 3450 1 57.15 1 1.11 — Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 LISTED APPROVED tings/Approval Details and Limitations, our website at www.anvilintlxom or act an Anvil• Sales Representative. Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT Project: ❑ Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SECTION 2 HANGERS AND SWAY BRACING SINCE © 1981 SUBMITTAL PACKAGE CPVC PIPE STRAPS gyp' f CPVC No Block Standoff.................................pg 1-2 CPVC Two Hole Strap.........................................pg 3 CPVC Two Hole Wrap Around Strap..............pg 4 CPVC Double offset .................pg 5 Stud Guards (Nail Plates)...................................pg 6 ARGCO.com 1 800-854-1015 VARGCO Updated 11/5/2020 ©ARGCO ARGCG.com eaG-esa-�G�s STAND—OFF TWO HOLE STRAP NO BLOCK FOR CPVC &us LISTED S. A©O SINCE I98IR • For mounting CPVC pipe to wood • Flared edges help protect CPVC • Galvanized steel construction • Supplied with #10 x 1" hex head cap screws • Complies with the static load requirements of NFPA® 13 • Suitable for fire protection installations • Eliminates spacers or backup blocks • Easy installation Designed to mount CPVC pipe horizontally or vertically to wood or composite wood joists with a minimum 3/8" thickness. Can only be used as a guide on top of beam or on vertical piping. May be installed to wood using supplied fastener or into (minimum 18 gauge) steel using two 1/4" x 1" TEK type screws. Provides vertical/lateral restraint and prevents upward movement of the pipe. For use as a restrainer in all sizes when attached to the bottom of structural wood members. For use as a restrainer in the 3/4 inch size when attached to the top of structural wood members. Installation: Per NFPA 13, 13R and 13D. (see next page) Fasteners: Wood - 3/4" to 3" CPVC Pipe - wood screw - no pre -drill Steel - 3/4" to 3" CPVC Pipe - 1/4" TEK screw CPVC DIMENSIONS ITEM # PIPE SIZE A B MAX. HANGER SPACING per NFPA13 2530180-3/4 3/4" 2.69" 3.25" 5.5 ft / 1.68 m 2530180-1 ill 2.94" 3.25" 6 ft / 1.83 m 2530180-1-1 /4 1-1 /4" 3.31 " 3.25" 6.5 ft / 1.98 m 2530180-1-1 /2 1-1 /2" 3.56" 4.5" 7 ft / 2.13 m 2530180-2 2" 4.06" 5" 8 ft / 2.44 m 25" O 011 1" System No. Location Spec Section Parag Submitted By Date Approved Date f raph ARGCO.com 1 800-854-1015 Updated 11/5/2020 © ARGCO VARGCO STAND-OFF TWO HOLE STRAP NO BLOCK FOR CPVC INSTALLATION INSTRUCTIONS J A©CO SINCE 1..I Designed to mount CPVC pipe to wood or composite wood joists with a minimum 3/8" thickness. All safety regulations required by the jobsite must be observed. *Observe all federal and local safety regulations *Wear safety glasses and hard hat at all times *Be aware of personnel working above and below *Wear gloves to avoid splinters and cuts. *When working above ground , be sure the structure will support your weight. 1. Snap strap over CPVC pipe. 2. Squeeze strap back around pipe Allow pipe to slide back and forth 3. Fasten the strap to the wood surface using the two hex head screws provided. For use as a restrainer in all sizes when attached to the bottom of structur- al wood members. For use as a restrainer in the 3/4 inch size when attached to the top of structural wood members. System No. Location Submitted By Date Spec Section Paragraph Approved Date ARGCO.conn 1 800-854-1015 XARGC0 Updated 11/5/2020 0 ARGCO AGC0.­ e00_a54-10- CPVC TWO HOLE STRAP ARCO SINCE O I981 C &US LISTED HEX HEAD SCREWS Designed for support or restraint for piping in either a vertical or horizontal position. It can be used on top or bottom of a beam. The edges are flared to prevent any damage to the CPVC pipe. It is easily attached using 2 hex head self -threading screws (supplied). Galvanized steel construction 1/4" 1. SNAP CPVC PIPE INTO HANGER 2. MOUNT HANGER TO UNDERSIDE OF BEAM WITH SCREWS PROVIDED NOTE: MAY ALSO BE USED ON TOP SIDE OF BEAM. ITEM # CPVC PIPE SIZE 2530283 3/4" 2530284 1" 2530285 1-1 /4" 2530286 1-1/2" 2530287 2" Galvanized carbon steel construction, supplied with hex slotted screws System No. Location Submitted By Date Spec Section Paragraph Approved Date ARGCO.com 1 800-854-1015 JrARGCO Updated 11/5/2020 ©ARGCO ARGCO.com e00-8�1, 15 CPVC STRAP TWO HOLE 900 WRAP AROUND C UL US LISTED *Top or bottom beam installation *Galvanized steel, supplied with 1" hex screws 1. Snap CPVC pipe hanger into pipe, dimples hold pipe in place 2. Mount hanger onto wood beam with screws provided NOTE: May also be used on the underside of beam. 3. Anchor tightly to surface, NOTE: Ensure that pipe can slide freely through hanger. ITEM # CPVC PIPE SIZE 2530175-3/4 3/4" 2530175-1 1" 2530175-1-1 /4 1-1 /4" 2530175-1-1 /2 1-1 /2" 2530175-2 2" Galvanized carbon steel construction; supplied with hex slotted screws [ bAR CO SINCE © I_ System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com 1 800-854-1015 VARGCO Updated 11/5/2020 0 ARGCO AR-0.- eoo-B -1015 CPVC PIPE HANGER SUPPORT DOUBLE OFFSET DESIGN Y A!W!-__M C Hanger & surge restraint for horizontal CPVC piping when installed on supporting structure -For mounting CPVC pipe to wood -Flared edges help protect CPVC -Galvanized steel construction *Supplied with #10 hex head cap screws -Complies with the static load requirements of NFPA® 13 -Suitable for fire protection installations *Size Range: 3/4" through 1" Designed to mount CPVC pipe horizontally or vertically to wood or composite wood joists with a minumum 3/8" thickness. Offset edge eliminates abrasion. Installation: Per NFPA 13, 13R and 13D. Install into wood or steel. Slides onto CPVC pipe. 314 " pipe size I Item #2530181-314 1"pipe size I Item #2530181-1 .�1 an System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com JrARGCO Updated 11/6/2020 © ARGCO ARGCO.com 600-8 -,0,6 STUD GUARDS/SAFETY NAIL PLATES S. AR CO SINCE © 1981 *Affix to the face of wood members to protect utility pipes and to protect nails from penetrating into hidden live wires (NMC Cable )which may be running through notches or through the drilled holes in the stud. *Nail Sharp Points *Easy to Install ITEM # SIZE STEEL THICK. 2530290 1-1/2" x 6" 18 GA 2530291 1-1/2" x 6" 18 GA 2530293 3" x 5" 16 GA 2530295 5" x 6" 16 GA System No. Location Submitted By Date Spec Section Paragraph Approved Date ARGCO.com 1 800-854-1015 ARGCO Updated 11/5/2020 © ARGCO ARGCO.- GOO-1015 SECTION 3 VALVES AND ACCESSORIES ES-A-2000B Series 2000B Double Check Valve Assemblies Sizes: 1/2" — 2" (15 — 60mm) Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • 1/2" — 2" 05 — 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • 1/2" — 1 " (15 — 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves LH - locking handle ball valves (open position) SH - stainless steel ball valve handles HC - 21/2" inlet/outlet fire hydrant fitting (2" valve) Prefix: U - union connections Pressure — Temperature Temperature Range: 33°F — 140°F (5°C — 60°C) Maximum Working Pressure: 175psi (12.06 bar) Standards AWWA Std. C510, IAPMO PS31 Job Name _ Job Location Engineer_ Approval_ Jk A M E S FIRE & WATERWORKS Or - - 2" 2000B HC (50mm) rp fc %" 2000B (20mm) Series 2000B Double Check Valve Assemblies shall be installed at referenced cross -con- nections to prevent the backflow of polluted water into the potable water supply. Only those cross -connections identified by local inspection authorities as non -health hazard shall be allowed the use of an approved double check valve assembly. Check with local authority having jurisdiction regarding vertical orientation, frequency of testing or other installation requirements. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, re- silient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B. Approvals ��pSSIFjFo H55E c °®C LuS cus 1015 B64.5 3/4" - 2" (LBV Models Only) Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. LBV models not listed. Horizontal and vertical "flow up" approval on all sizes. P.O. No. Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www. amesfirewater. com Dimensions - Weights A Suffix HC - Fire Hydrant Fittings dimension "A" = 231/2" (594mm) SIZE (ON) DIMENSIONS WEIGHT in. mm A in. mm in. B mm C in. mm F in. mm G in. mm H in. mm in. mm lbs. kgs. '/2 15 10 254 4% 117 2'/6 62 5 127 3% 85 26/6 59 2'/16 52 4.5 2 3/4 20 111/ 282 4 102 31/8 79 63/6 157 37/6 87 2'/a 54 1Vii6 33 5 2.3 1 25 13'/4 337 51/8 130 4 102 7'/2 191 3% 85 1P/6 43 111/16 43 12 5.4 11/4 32 16% 416 5 127 36/6 84 91/ 241 5 127 3 76 2 50 15 6.8 11/2 40 163/4 425 4'/3 124 31/2 89 93/4 248 513/6 148 31A 79 211/6 68 15.86 7.2 2 50 19'/2 495 61/4 159 4 102 13% 340 61/8 156 37/6 87 2"/6 68 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. 'Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 112" (15mm) N 83 12 0 69 10 N 55 8 3 41 6 N 28 4 N 14 2 I1 0 0 0 2 4 6 8 10 12 gpm AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Flow Rate I IIIIIIIIIIIII■IIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIIIIIIII��IIIIIIIIIIIII■IIIIIIIIIIIII■ I IIIIIIIIIIIII■IIIIIIIIIIIIII■■ IIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■��IIIIIIIIIIIII■IIIIIIIIIIIII■IIIIIIIIIIIII■ IIIIIIIIII�IIIIIIIIIIIII■■ II�IIIIIIIIII�IIIIIIIIIIIII■��IIIIIIIIIIIII■IIIIIIIIIII�IIIIIIIIII� kPa psi 96 14 N 83 12 o 69 10 y 55 8 j 41 6 28 4 a. 14 2 0 0 111AII f49mm1 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 1 *12" (40mm) 83 12 N 69 10 0 55 8 d 41 6 3 28 4 d14 2 12 0 0 pp0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate N kPa psi II N y 110 16 1 (25mm) 0 * J 83 12 i d 69 10 W 3 55 8 aNi H 41 6 Ii 28 4 IL 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm AP 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps kPa psi 2" (50mm) 83 12 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm OP 0 95 190 285 380 475 570 665 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate AwIMPORTANT Inquire with governing authorities for A M E S local installation requirements. • 9UU1 FIRE&WATERWORKS A Division of Watts Regulator Company www.amesfirewater.com I CERTIFIED 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-2000B 0521 ©Ames Co. 2005 FPPI" A- 06-844-00 c u, us FM LISTED APPROVED Ball Valves, Forged Brass, UL/ULc Listed, FM Approved FPPI's complete line of TrimFit Forged Brass*, Full Port Ball Valves feature forged components machined to exacting specifications. UL/ULc listed and FM approved. Listed for fire sprinkler systems for trim, test or drain applications, our Full Port Ball Valves are rated 600 PSI for sizes 1/2" - 11/2" IPS and 300 PSI for the 2" size. Each valve is complete with plastic coated valve handle marked as required by UL. Blow out proof stem. Materials • Nut: Steel • Handle: Steel • Stem Gland: Brass* • Stem Packing: PTFE • Stem: Brass* • Body: Forged Brass* • Ball Disc Pack: PTFE • Ball Disc: Chrome Plated Brass or Forged Brass* • End Plug: Forged Brass* *Contains lead. Not for use in water systems intended for human consumption. *Full port valves have slightly larger "take out" dimensions than standard port valves. You may need to adjust trim components accordingly. 211(QJill Q l 11ll711 Part No. Description in Pack Qty. 06-838-00 Ball Valve 1/4 10 06-840-00 Ball Valve 1/2 10 06-842-00 Ball Valve 3/4 10 06-844-00 Ball Valve 1 8 06-845-00 Ball Valve 11/4 4 06-846-00 Ball Valve 11/2 4 06-848-00 Ball Valve 2 2 ON (NPT) B H L in mm mm mm 1/4 42.5 58.8 107 1/2 52.8 77 121.5 3/4 60.5 81 140 1 74 93 147 11/4 87.5 110.7 194 11/2 98.8 122.2 199.5 2 113 146 223.5 SA11('IlH-COOPER 32 N z E R N A r 1 o N A L CUSTOMER SERVICE I TOLL FREE +1 (800) 344-1822 1 FAX +1 (800) 344-3775 1 www.fppi.com SECTION 5 FIRE SPRINKLERS March 14, 2008 Sprinkler 41a MICROFAST@ AND MicrofastHP® QUICK N11UN7C7*;JJJJ RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast° and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive, glass -bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and Teflon° coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificate G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. No. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC -certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CPD-40170 MED Certified: Standard EN 12259-1, EC -certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 41d and Design Criteria on page 41e for cULus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass -bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 06666B, Added Dry System note in approval chart for Small Orifice.) Sprinkler 41 b March 14, 2008 MICROFAST@ MicrofastHP® QUICK N11UN7C7*1j RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com For Teflon° Coated Sprinklers: Belleville Spring -Exposed, Screw -Nickel Plated, Pip Cap -Teflon° Coated For Polyester Coated Sprinklers: Belleville Spring -Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast° and MicrofastHP° Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon° = N Temperature Suffix (°F/°C): 135°/68° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141 ° = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for coated and/or recessed sprinklers: Part No. 12144W/B*' (available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/B. **A'/z' ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast° and MicrofastHP° Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Slats Protective Sprinkler Cap V896 Figure 1: Standard Sprinkler Wrench 10896W/13 March 14. 2008 Sprinkler 41 c MICROFAST° AND MicrofastHPO QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135 -F (57 -C) 100 -F (38 -C) Orange Ordinary 155 -F (68 -C) 100 -F (38 -C) Red Intermediate 175 -F (79 -C) 150 -F (65 -C) Yellow Intermediate 200 -F (93 -C) 150 -F (65 -C) Green High 286 -F (141 -C) 225 -F (107 -C) Blue Sprinkler Finishes: Brass, Chrome-Enloy°, White Polyester, Black Polyester, and Black Teflon° Corrosion -Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon° Footnotes ' The sprinkler temperature rating is stamped on the deflector. ' Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion -resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 41d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. v — Sprinkler Wrench 12144W/B)K)K for installing coated and/or recessed pendent sprinklers with protective caps L.------.J AKA 112' ratchet is required (not available from Viking), Carefully slide the wrench sideways around the protective cap, ensuring engage- ment with the sprinkler wrench flats, Sprinkler 41 d March 14, 2008 MICROFAST@ MicrofastHP® QUICK N I IU N7C7*0i Jill RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Approval Chart Temperature KEY Microfast° and MicrofastHP®Quick Response Pendent Sprinklers Finish p p A1X � Escutcheon (if applicable) Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT BSP U.S. metricz Inches mm cULus4 FM' NYC' VdS LPCB E 0 Standard Orifice 066626 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 A1X, B1Y I A3X, 133Y A1X, B1Y A3 A3X, 63Y C3X, E3Y13 C3X, E3Y15 Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 A1X, B1Y A2X, 132Y A1X, B1Y -- A3X C313 -- 12104 VK352 3/4" 20 mm 8.0 115.2 2-1/4" 58 -- -- G3 -- -- -- 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 AIX, B1Y -- A1X, B1Y A3 -- -- -- Small Orifices 06718610 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 A1X, B1Y A2X A1X, B1Y -- -- -- -- 06720B10 VK331 1/2" 15 mm 4.2 60.5 2-1/4" 58 A1X, B1Y A1X, B1Y -- -- -- -- 06932B VK331 -- 10 mm 4.2 60.5 2-3/8" 60 -- -- A3 -- G214 -- Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metricz Inches mm cULus4 FM NYC" VdS LPCB C E 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 A1X, B1Y -- A1X - -- -- -- Maximum 250 PSI (17 bar) WWP Small Orifices 1229010 VK342 1/2" 15 mm 2.8 40.3 2-3/16- 56 A1X, B1Y -- A1X -- -- -- -- Approved Temperature Ratings Approved Escutcheons A- 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), Approved Finishes X - Standard surface -mounted escutcheon or and 286 OF (141 °C) OF °C), OF °C), OF 'C), °F 'C) 1 - Brass, Chrome-Enloy®, White Poly- the Viking Microfast° Model F-1 Adjustable B - 135 (57 155 (68 175 (79and 200 (93 C - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), and 286 OF ester'', Black Pol ester' 8, and Black y Escutcheon12 (141 °C) Teflon®' Y - Standard surface -mounted escutcheon or D - 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), and 286 OF 2 - Brass and Chrome-Enloy" the Viking Microfast° Model F-1 Adjustable (141 °C) 3- Brass, Chrome-Enloy°,White Polyesters, Escutcheon12 or recessed with the Viking E - 155 OF (68 °C), 175 OF (79 °C), and 200 OF (93 °C) OF °C), OF °C), OF °C) and Black Polyester' Micromati& Model E-1 or E-2 Recessed F - 155 (68 175 (79 and 286 (141 OF °C) Escutcheon G - 155 (68 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. z Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 FM Approved for use only in wet -pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. ' Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. ' cULus Listed as corrosion resistant. ' Other colors are available on request with the same Listings and Approvals as the standard colors. s Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 10The sprinkler orifice is bushed. "Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. 12The Viking Microfast® Model F-1 Adjustable Escutcheon is considered a surface -mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 13 C E Certified, Standard EN 12259-1, EC -certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 14 C E Certified, Standard EN 12259-1, EC -certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 15 0 MED Certified, Standard EN 12259-1, EC -certificate of conformity 0832-MED-1003 and 0832-MED-1008. March 14. 2008 Sprinkler 41 e MICROFAST° AND MicrofastHPO QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com AL DESIGN CRITERIA (Also refer to the Approval Chart on page 41 d) cULus Listing Reauirements: Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Aaoroval Reauirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. 1/2" (15 mM) NPT C�➢91a01o0 2-1/4" 1-5/8" (58 mm) (4 Pendent Sprinkler 06662B (VK302) Ceiling opening Size: 2-5/16" (58.7 mm) minimum 2-1/2" (63,5 mm) maximum iSW WE\ 1-3/4" (44.5 mm) Installed with a standard 1/8" surface - mounted escutcheon, (54 mm) 2" 1-1/2" (38.1 mm) (50.8 mm) Minimum Maximum Installed with a Microfast Model F-1 Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Sprinkler 41f March 14, 2008 MI R FA T° AND MicrofastHP° QUICK N I IU N7C7*;jjjj RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com 2-1/8" Celling ❑penlrg Size: 2-1/8, (54 mm) 2-5/16' (58,7 mm) minimum (54 mm) 2-1/2' (63.5 mm) maximum 1-3/4° 1-1/8' (28,6 mm) (44,5 mm) Minimum Maximum Installed with a Mlcromatic Model E-1 Recessed Escutcheon 21 1-1/8' (28,6 mm) (50,8 mm) Minimum Maximum ��2 t Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_081296 Replaces page 41 a-f, dated October 12, 2007. (Added I-Ii Approval and updated CE Approval for Sprinkler 06666113, Added Dry System note in approval chart for Small Orifice.) Bulletin 157 Rev. J Ill Features 1. The Model F30R sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. 2. Styles available • Pendent • Recessed FP Pendent • Recessed F1 Pendent • Concealed • Horizontal Sidewall • Recessed FP Horizontal Sidewall • Recessed F1 Horizontal Sidewall 3. 11/2" (38mm) escutcheon adjustment on pendent sprinkler. 4. 1/2" (13mm) escutcheon adjustment on recessed sprin- kler with push -on/ thread -off FP Model Escutcheon ring. 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push -on/ thread -off CCP Cover Plate. 6. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. 7. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. 8. Lengths available to accommodate installation di- mensions from 2" - to - 48" (51 mm - to - 1219mm), in '/4" (6mm) increments. See specific styles for correct "A" dimension range. 9. Available in a variety of plated and painted finishes. 10. Polyester Coated or Electroless Nickel PTFE (Teflon°)* Plated Corrosion Resistant Sprinklers. *Concealed Sprinkler is not corrosion resistance. US Patent Numbers 5,775,431 and 5,967,240. Other US Patents pending. Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Style Response Sprinkler System TvDe Hazard Pendent Recessed Pendent Wet Pipe Light Recessed F1 Pendent Quick Dry Pipe Ordinary CCP Concealed All Preaction R5714 Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Quick Dry Pipe Light R5734 All Preaction 2. Certified by FM Approvals Style ty Response p Sprinkler System Type Hazard Pendent Wet Pipe Light Ordinary, Recessed F1 Pendent Quick Dry Pipe Groups (R5714) All Preaction 1&2 Horizontal Sidewall Wet Pipe Recessed F1 Horizontal Sidewall Quick Dry Pipe Light R5734 All Preaction 3. NYC MEA 258-93-E "DuPont Registered Trademark Model F3QR Quick Response Dry Sprinklers A�14 1-0 Pendent (See Fig. 1) Recessed FP Pendent (See Fig. 3) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Concealed (See Fig. 4) Horizontal Sidewall (See Fig. 6) I^ Horizontal Sidewall / HB (See Fig. 7) Recessed F1 Horizontal Sidewall (See Fig. 9) The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Dry Pendent Sprinkler Model F30R Dry Pendent w/HB Escutcheon "A" Dim. 2" to 48" (51 mm to 1219mm) in %" (6mm) increments "A" Dim. 31/2" to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes"' Sprinkler Escutcheon Electroless Nickel PTFE(Teflon®)*j4> Electroless Nickel PTFE (Teflon®) Bronze Brass (3) Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. 4) cULus listed Corrosion Resistant - TJ-�F___�i �- system Tee 1" NPT 2 1/8" Din. Omm] "A" Dimension Hole inCeiling Adjustment Range —1/4" [-6.4mm] 1 43/64" Dia. +1 1/4" [+31.8mm] [42.5mm] 1 1/2" [38.1mm] Total Adjustment Sprinkler Can Ceiling 1 1/4" [31.8mm] 1/4" [6.4mm] Escutcheon Escutcheo n Ceiling Adjustment n1 5/8" Nominal Positian� [41.3mm] of Escutcheon 1/4" [6.4mm] Protrusion 3" Did. [76.2mm] NFW15]FC01 Fig. 1 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides -1/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F3QR Dry Recessed FP Pendent Sprinkler "A" Dim. 31/2" to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes"' Sprinkler Escutcheon Electroless Nickel PTFE(Teflon6)*(3) Electroless Nickel PTFE (Teflon" )*(4) Bronze Brass Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. Only the escutcheon will contain desired finish. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. (4) Cup and Escutcheon Electroless Nickel PTFE (Teflon°)" Plated. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Ratina Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200oF (93°C) 150°F (66°C) Green H' h(1) 286°F 141°C 225°F 107°C Blue Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green Hi h 286°F 141°C 225°F 107°C Blue Listed and Certified only by cULus. Electroless Nickel PTFE (Teflon®)" Plated sprinklers, escutcheons and cups are recommended for exterior applications. System Tee "A" Dimension 2 1/2" [63.5mm] 1" NPT Adjustment Range pia. Hole in Ceiling —1/2" [-12.7mm] 3 1/2" [88.9mm] +1/2" [+12.7mm] Escutheon Di,. Escutheon Adj. Ceiling 1" [25.4] Escutcheon Total Adj. 1/2" [12.7mm] Escutheon Adj. Position Sprinkler Can oNominal f Escutcheon 1-1/4" [31.75mm] 1 Nominal Protrusion 35/8" [41.mm] 2 13/64" [55.88mm] Dia. NEW15]FG02 Fig. 2 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. "I - � System Tee 2 1/2" Dia. [63.50mm] "A" Dimension Hole in Ceiling Adjustment Range 31/4" 2 19/64" Dig. [36.35mm] [58.34mm] Nominal Position of Escutcheon Ceiling 1/4" [6.35mm] Escutcheon Adjustment 1/4" [6.35mm] 3 7/32' Dig. Escutcheon AdjustmentL [81.76mm] 1/2" [12.7mm] Total Adjustment 1" APT Sprinkler Cup Assembly Escutcheon Ceiling NEW157FG03 i Fig. 3 Sprinkler cup and FP Escutcheon fabricated of steel and recommended Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprin- for interior applications. kler in ceilings which have positive pressure in space above. M Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 "DuPont Registered Trademark 2. Model F30R Dry Pendent Concealed Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments ('P (`nvor Plata "' Fini¢hoe 121 Standard Finishes Spec! I Application Finishes Chrome Plated Bright Brass Plated White Black Plated Black Paint Off White Satin Chrome Utilizes the 1/2" cover plate with 3/8" total adjustment. 21 Other finishes and colors are available on special order. Consult factory for details. Standard Temperature Ratings Sprinkler Cover Plate Max. Classification Temperature Temp. Rating Ambient Rating Temp. Ordinary 135oF (57oC) 135-F (57oC) 100-F (38oC) Ordinary 155-F (68-C) 135-F (57oC) 100-F (38oC) Intermediate (1) 175oF (79oC) 165oF (74oC) 150'F (66aC) Intermediate 200-F (93oC) 165-F (74oC) 150-F (66oC) High(') 286aF (141 aC) 165-F (74-C) I 150-F (66aC) Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of brass and recommended for interior applications. (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F3QR Dry Recessed F1 Pendent Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (1) Sprinkler Escutcheon Collar Electroless Nickel Electroless Nickel Electroless Nickel PTFE(Teflon®)*(3) PTFE (Teflon")* PTFE (Teflon")* Chrome Chrome Chrome White Polyester (2) White White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57oC) 100-F (380C) Orange Ordinary 155-F (68-C) 100-F (38oC) Red Intermediate 1 175'F (79'C) 150OF (66aC) Yellow Intermediate 200-F (93oC) 150OF (66aC) Green High (1) 286aF (1410C) I 2250F (107oC) I Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 "DuPont Registered Trademark II;i�e i �- System Tee 1" NPT 2 1/2" Dig. [6.35mm] "A" Dimension Hole in Ceiling Adjustment Range f 3/16" 2 19/64" Dig. [t4.76mm] [58.34mm] Nominal Position of Coverplate Sprinkler Cup Assembly Coverplate Ceiling Assembly Ceiling 3/16" [4.76mm] Coverplate Adjustment 3/16" [4.76mm] 3 5/16" Di, Coverplate Adjustment [84.13mm] 3/8" [9.53mm] Total Adjustment NEW157FG04 Fig. 4 Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler in ceilings which have positive pressure in the space above. �---- v- -------2--MF— II 1 I I ly�iiii I �- System Tee 2 1/2" Dig. " NPT [63.50mm] Hole in Ceiling 1 15/16" "A" Dimension [49.2mm] Adjustment Range t 1/4" [t6.35mm] 15/16" Nominal Position [23.8mm] of Escutcheon Sprinkler Cup Assembly Ceiling 1 /8" Ceiling 1 /4" [6.35] 4" Escutcheon Adjustment 4p(� Escutcheon Adjustment Escutcheon 1/2" [12.7mm] Adjustment 2 27/32 NEW157FG05 [72.2mm] Fig. 5 3. Model F3QR Dry Horizontal Sidewall Sprinkle Model F3QR Dry HSW w/HB Escutcheon "A" Dim. 2" to 48" 51 mm to 1219mm in 1/4" 6mm increments "A" Dim. 31/z' to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes"' Sprinkler Escutcheon Electroless Nickel PTFE(Teflon°)"(4) Electroless Nickel PTFE (Teflon(DY Bronze Brass() Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. (4) cULus listed Corrosion Resistant 1 1/2" [38.10mm] Total Adjustment Ceiling r = T 4" [101.60mm] Mir 1 1/4" [31.75mm]a 12" [304.80mm] M Escutcheon Adjustmen System Tee tcheon Adjustment 1" NPT 3/32" .18mm] 3" [76.20m m] 2 1/8" Dia. - [53.98mm] Hole in Wall 1/4" [6.35mm] Sprinkler Can Protrusion "A" Dimension Adjustment Nominal Position Range - 1/4" [-6.35mm] of Escutcheon N£WI57FC06 + 1 1/4 [+31.75mm] Fig. 6 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135OF (57OC) 100°F (38°C) Orange Ordinary 155OF (68OC) 100°F (38°C) Red Intermediate (1) 1750F (790C) 150°F (66°C) Yellow Intermediate 200OF (930C) 150OF (66°C) Green High 2860E 1410C 225°F 107°C Blue (1) Listed and Certified only by cULus. 1" [25.4mm] Total Adjustment Ceiling 1/2" [12.7mml Escutcheon Adjustment 4" [101.60mm] Min. mm 12" [304.80mm] Max. Escutcheon Adjustment 2 3/32" System Tee 3 [53.18mm] 1" NPT 2-13/64" 3-1/2" [55.88mm] [88 9mm] Did. Escutcheon Dia. 2 1/2" Di.. [63.5mm] Hole in Wall 1-1/4" [31.75mm] Nominal Protrusion "A" Dimension Sprinkler Can Escutcheon Adjustment Ncwrnrco� Rongs + 1/2' [+12.7mm] — 1/2" [-12.7mm] Nominal Position of Escutcheon Fig. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Model F30R Dry Recessed FP Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (1) Sprinkler Escutcheon Electroless Nickel PTFE(Teflon11)'(3) Electroless Nickel PTFE (Teflon" )*(4) Bronze Brass Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. "See page 2" (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. (4) Sprinkler's can and FP Escutcheon Electroless Nickel PTFE (Teflon®)` Plated recommended for exterior applications. Standard Temperature Ratings Classification Sprinkler Tem- erature Rating Max. Ambient Temp. Bulb Color Ordinary 135°F (57°C) 100°F (380C) Orange Ordinary 155°F (68°C) 100°F (380C) Red Intermediate (1) 175°F (79°C) 150°F (660C) Yellow Intermediate 200OF (93°C) 150OF (660C) Green High 2860E 141°C 2250E 107°C Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 F Ceiling 13/32" Escutcheon [35.7mm] 4" [101.6mm]Min. System Tee Cup 3 12" [304.fimm]Max.'� �1" NIT 3 7/32" Dia. 81.8m_ �m] 2 1/2" Di [63.5mm] = Nominal Position 1 Hole Wall 3 of Escutcheon 2 19/64" Di.. [58.3mm] 1/4" [6.35] Escutcheon Adjustment "A" Dimension Adjustment Range 1 t0 n Adj t NEWtS�FGOB i1/4" Escutcheon Adjustment [36.35mm] Escut1/4" [6.351 cheon Adjustment =k • FOR FACTORY MUTUAL (FM) • 4" — 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 8 Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler in walls which have positive pressure in their side space. • Listed by cULus for Quick Response. Approved by FM for Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. "DuPont Registered Trademark 4. Model F3QR Dry Recessed F1 Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (1) Sprinkler Escutcheon Collar Electroless Nickel Electroless Nickel Electroless Nickel PTFE(Teflon6)"(3) PTFE (Teflon®)` PTFE (Teflon®)" Chrome Chrome Chrome White Polyester (2) White White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (8) cULus Listed Corrosion Resistant Sprinkler. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57oC) 100oF (38oC) Orange Ordinary 155-F (68oC) 100oF (38oC) Red Intermediate (1) 175oF (79oC) 150oF (66oC) Yellow Intermediate 200-F (93oC) 150oF (66oC) Green High (1) 286aF (141aC) 225aF (107aC) Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Technical Data: Orifice Size:'/z" (15mm) Thread Size: 1" NPT per ANSI B2.1 Working Pressure: 175 psi (12 bar) Nominal K Factor - US / (Metric): 5.6 / (80) Product Description Reliable Model F3QR Dry Sprinklers are quick response sprinklers utilizing a durable 3mm frangible glass bulb. This quick response enables these sprinklers to apply water to a fire much sooner than standard response sprinklers of the similar temperature rating. Model F3QR Dry Sprinklers are intended for use in dry and preac- tion systems and in areas subjected to freezing temperatures, such as freezers and unheated portions inside and outside buildings. Environments wherein dry sprinklers are employed can be cor- rosive. For this reason, Model F3 Sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminents from entering the internal portion of the drop nipple. The wax must not be removed. Operation The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. When the temperature increases sufficiently, due to a fire, the bulb shatters allowing operating parts to clear the waterway. This enables the inlet seal to release air or water and subsequently, cause water flow over the deflector in a uniform spray pattern, controlling or extinguishing the fire. F Ceiling 1 Escutcheon �^1 [3.2mm] �= 4" [101.6mm]Min. System Tee SpAssembly rinkler Cup 1" NPT 3 12" [304.8mm]Max. ref 1 2 27/32" [72.2mm] \\� << 2 1/2" Di �—� [63.5mm] Hole in Wall 31 Nominal Position 1 15/16" [^- of Escutcheon [49.2mm] 1/4" [6.35] Escutcheon Adjustment "A" Dimension 1/2" [12.7mm] NEW157FG09 Adjustment Range Adjustment 31/4" [F6.35mm] 1 [6.35] Escu/4" tcheon Adjustment # • FOR FACTORY MUTUAL (FM) • 4" — 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 9 Listed by cULus for Quick Response. Approved by FM for Standard Response. Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. Ordering Information Specify: 1. Sprinkler Type select one): (a) Model F3QR Dry Pendent (b) Model F3QR Dry Pendent/HB (c) Model F3QR Dry Recessed FP Pendent (d) Model F3QR Dry Recessed F1 Pendent (e) Model F3QR Dry Concealed Pendent (f) Model F3QR Dry Horizontal Sidewall (g) Model F3QR Dry Horizontal Sidewall/HB (h) Model F30R Dry Recessed FP Horizontal Sidewall (i) Model F30R Dry Recessed F1 Horizontal Sidewall 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Escutcheon type (F1 or FP). 5. Cover Plate/Escutcheon Finish. 6. Length: "A" Dimension (face of tee to face of ceiling or wall) in (6mm) increments. 7. Model F3QR Dry Pendent (a) is available without sprinkler can and escutcheon. Note: 1. The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI B2.1 [71/2 threads approximately]. 2. All platings and paintings are decorative and intend- ed for interior use. "DuPont Registered Trademark 5. General Installation Instructions Model F3QR dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC*, the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in ac- cordance with the diagrams. The "A" dimension of the dry sprinkler, which extends into the freezers or a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 10. Caution: Do not install Model F3QR Dry sprinklers into CPVC adapter fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 11. During installation, the following steps must be followed 1. Cut the specified size hole (see illustrations) for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model F3 or XLO2 Sprinkler Wrench as specified. 3. Install the Model FP push -on / thread -off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F30R Concealed and Recessed In- stallation Instructions • The Model XLO2 wrench (Fig. 12) is designed to lo- cate on the wrenching pads of the recessed sprin- kler while centering in the cup. A standard'/2" drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. • Model F3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Model F30R Quick Response Dry Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non - operation. Caution: Use specified by RASCO wrenches only, which are designed to engage sprinkler's wrenching pad. (Fig. 15, page 9) RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) AMBIENT TEMPERATURE OF PROTECTED AREA" AT THE DISCHARGE END OF THE SPRINKLER EXPOSED BARREL AMBIENT TEMPERATURE 40'F/4'C I 50'F/101C I 60'F/16'C EXPOSED MINIMUM BARREL LENGTH** (FACE OF TEE TO TOP OF CEILING) IN. MM IN. MM IN. (MM) 40-F (,VC) 0 0 0 30-F (-1'C) 0 0 0 20-F (-TC) 4 (101) 0 0 10-F (-ITC) 8 (203) 1 (25.1) 0 O'F (-IVC) 12 (305) 3 (75) 0 -10'F (-23'C) 14 (356) 4 (101) 1 (25.1) -29F (-29'C) 14 (356) 6 (152) 3 (75) -30'F (-34'C) 16 (406) 8 (203) 4 (101) -40'F (-40'C) 18 (457) 8 (203) 4 (101) -50-F (-46'C) 20 (508) 10 (254) 6 (152) -60-F (-51'C) 20 (508) 10 (254) 6 (152) WET _JIWL1__L__ I 1 MINIMUM OSED (HEATED AREA) EXP BARREL LENGTH i 'A' CLEARANCE DIMENSION HOLE x I • THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. I THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE END OF THE SPRINKLER. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES USTED, USE THE NEXT COOLER TEMPERATURE. -THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH CEILING WIND VELOCITIES IN THE PROTECTED AREA (PROTECTED AREA) INSTALL 1 INCH NPI THREADED END OF DRY PENDENT SPRINKLER INTO THE 1 INCH NPI SIDE OUTLET OF A MALLEABLE IRON TEE FITTING PER ANSI B 16.3 CLASS 150) OR CAST IRON THREADED TEE FITTING PER ANSI 16.4 (CLASS 125) ONLY. IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. SEAL THE CLEARANCE SPACE AROUND THE SPRINKLER TO AVOID LEAKAGE OF AIR INTO THE PROTECTED AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH COULD INHIBIT OPERATION OR CAUSE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS. ESCUTCHEON 1-3" DIA�I *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE 1 VIA-7-1 1i L j L J (HEATED AREA) (HEATED AREA) MINIMUM MINIMUM EXPOSED EXPOSED BARREL 1 BARREL LENGTH DECKTITE FLASHING _j INSIDE FACE SEAL LENGTH (SEE ABOVE) RASCO #4003910 I (SEE ABOVE) (RECOMMENDED) 1 CLEARANCE HOLE 1 INSULATED FREEZER 1 I OR COOLER STRUCTU4RE .......... . .::'. .'.:'. .'. I '.': .':.':.'::.':.'::.':.': .' OR EXTERIOR FRAMIN ...................... , ................... (PROTECTED AREA) III I� A DRY SPRINKLER V f�1:1 /IV IN COLD AREA Fig. 10 7. (PROTECTED AREA) DRY SPRINKLER IN COLD AREA NEW157FG10 *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION FEMALE FEMALE PIPE PIPE . THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE 1 SHORTER LONGER INLET INLET MALE MALE PIPE PIPE THREAD THREAD MODEL F3-PL, MODEL F3QR-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3, DRY SPRINKLER MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fgO8A Fig. 11 m Fig. 12 - XL02 Wrench Fig. 13 - XL02 Wrench 15- Fig. 14 - XL02 Wrench 0 Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured b The Reliable Automatic Sprinkler Co., Inc. ® Recycled iablL® (800) 431-1588 Sales Offices Paper s (914) 848-2051 Sales Fax (800) 8-0Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 01/14 P/N 9999970175 Page 1 of 7 N4 I Kj® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) 2 3. The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Freedom@ Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. Features: • K4.9 (70.6 metric) • Fast response glass bulb operating element. • Integral threaded adapter cup accepts push -on or thread -on cover plates. • Low -profile, small diameter, removeable cover plates offer almost flush appearance upon installation and allow ease of maintenance. • Protective cap prevents damage during installation and ceiling finishing and keeps errant overspray from coating internal parts. • Various finishes available to meet design requirements. • Optional Electroless Nickel PTFE (ENT) coating provides corrosion resistance (see Approval Chart). LISTINGS AND APPROVALS c 4L us cULusEU Listed: Category VKKW EO Refer to the Approval Charts and Design Criteria for C-UL-US-EU Listing requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 WARNING: Cancer and Reproductive Harm - psi (34.5 bar). www.P65Warnings.ca.gov Thread size: 1/2" (15 mm) NPT Nominal K-factor: 4.9 U.S. (70.6 metric*) Glass -bulb fluid temperature rating: to -65 °F (-55 °C) " Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Beryllium Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel JIS G3141 and Carbon Steel UNS-G10100 (per JIS G3141) Shipping Cap: High Density Polyethylene Vibration damper ring: Buna-N Rubber SAE AS-568-017 Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches the cover plate's nominal temperature rating, the cover plate detaches and releases the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand. When the temperature reaches the sprinkler's nominal temperature rating, the glass bulb shatters releasing the yoke, pip cap assembly and sealing spring. Water begins flowing through the sprinkler orifice and strikes the deflector form- ing a uniform spray pattern over a specific area of coverage, which is determined by the water supply pressure at the sprinkler, in order to extinguish or control the fire. Form No. F_012116 Rev 03 April 2023 Replaces Form No. F_012116 Rev 02 (Replaced wrench 24339 with 23143.) Page 2 of 7 N4 I Kj® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Ordering Instructions: (1) Select a sprinkler base part number (2) Add the suffix for the desired finish (3) Add the suffix for the desired sprinkler temperature rating (4) Order a cover plate (Must be ordered separately; refer to Table 2) Example: 23707AE = 200 °F (93 °C) Temperature rated sprinkler with a standard brass finish. Sprinkler Size 1: Finishes 2: Temperature RatingS5 Base Part NPT Max. Ambient Ceiling Number' Inch Description Suffix Nominal Rating Bulb Color Temperature Suffix 23707 1/2 Brass A 155 °F (68 °C) Red 100 °F (38 °C) B ENT3,4 JN 200 °F (93 °C) Green 150 °F (65 °C) E Accessories Part Description Number 23143 Installation wrench 14412 Small concealed cover plate installer tool; requires a piece of 1" PVC pipe or similar to attach (available since 2007). 14867 Large concealed cover plate installer tool; requires a piece of 1" PVC pipe or similar to attach (available since 2007). 01731A Sprinkler cabinet; holds up to 6 sprinklers (available since 1971). Footnotes 1 Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. s. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. cULusEU listed as corrsion resistant. 4. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 5. The sprinkler temperature rating is stamped on the deflector. e. The installation wrench is intended to be used for a maximum of 500 sprinkler installations at a maximum torque of 14 ft-lbs (19 Nm). Figure 1: Installation Wrench Form No. F_012116 Rev 03 April 2023 Page 3 of 7 N4 I Kj® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com COVERTABLE 2: ORDERING •R• Instructions: (1) Select a cover plate base part number (2) Add the suffix for the desired finish (3) Add the suffix for the required cover plate nominal rating. Example: 23190MCIW = 165 °F (74 °C) Temperature rated, 2-3/4" (70 mm) diameter, thread -on style, round cover plate with a painted white finish. 1: Select a Cover Plate Base Part Number' 2: Select a Finish Thread-OnPush-On Base Part Size Base Part Size Type Type Description Suffix° Number' Inch (mm) Number Inch (mm) 23190 2-3/4 (70) Round 23447 2-3/4 (70) Round Polished Chrome F 23174 3-5/16 (84) Round 23463 3-5/16 (84) Round Brushed Chrome F-/B 23179 3-5/16 (84) Square 23482 3-5/16 (84) Square Bright Brass B 23193 5 2-3/4 70 ( ) Stainless 23455 5 2-3/4 70 ( ) Stainless Antique Brass B-/A Brushed Brass B-/B Steel Round Steel Round 231835 3-5/16 (84) Stainless 234735 3-5/16 (84) Stainless Brushed Copper E-/B Painted White M-/W Steel Round Steel Round Painted Ivory M-/I Painted Black M-/B 3: Temperature Rating Matrix' z Cover Plate Nominal Temperature Sprinkler Nominal Rating Sprinkler Maximum Ambient Suffix Rating (Required) Classification Ceiling Temperature 139 °F (59 °C) Ordinary 155 °F (68 °C) 100 °F (38 °C) A 165 °F (74 °C) Intermediate 200 °F (93 °C) 150 °F (65 °C) C Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. z. The sprinkler temperature rating is stamped on the deflector. s. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 4. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 5. Stainless Steel versions are not available with any finishes or paint. Form No. F_012116 Rev 03 April 2023 Page 4 of 7 ® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 4.9 K-factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the Design Criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base SIN Thread Size Nominal K-factor Maximum Water NPT BSPT U.S. metric 2 Part Number Working Pressure 23707 VK494 1/2" 15 mm 4.9 70.6 175 psi (12 bar) Max. Coverage Area 6 Flow Pressure Listings and W X L GPM (LPM) PSI (bar) Deflector Installation Approvals3,5 Minimum SF aci g 155 °F (68 °C), 200 °F (93 °C) cULusEUa Ft. X Ft. to Ceiling Type (m) (m X m) Temperature Rated Sprinklers 12 X 12 13 7.0 3.7 X 3.7 49.2 0.48 14 X 14 13 7.0 4.3 X 4.3 49.2 0.48 Refer to Concealed with Cover Plate As- See Footnotes 8, & 9 8 16 X 16 13 7.0 4.9 X 4.9 49.2 0.48 Figure 5 sembly. (2.4) 18 X 18 17 12.0 See Footnote 7. (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 6.1 X 6.1 75.7) 1.15 Footnotes Part number shown is the base part number. For complete part number, refer to the current Viking price schedule. Y. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. <. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. Meets New York City requirements, effective July 1, 2008. 6. For areas of coverage smaller than shown, use the "Flow' and "Pressure' for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure' used. 7 Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 2. 6. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 7. e. cULusEU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) DESIGN CRITERIA o refer to the Approval Chart. UL Listing Reauirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 9.5.2.1 or 10.2.4.1.2 of the current edition of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance witTii the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities awing Jurisdiction. Form No. F_012116 Rev 03 April 2023 Page 5 of 7 ® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 2: Identification of Custom Paint Figure 3: Square Cover Assembly ''/2'NPT (15 mm BSPT) All (57 mm) 3'/4" (83 mm) NOTE: Image is representative only. Actual product may vary. Figure 4: Sprinkler Dimensions Form No. F_012116 Rev 03 April 2023 Page 6 of 7 N4 I Kj® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Minimum required opening in the ceiling l pipe engagement %6" (11 mm) Nominal pipe engagement'/,6" (11 mm) NOTE: Image is representative only. Actual product may vary. Figure 5: Sprinkler Installation Dimensions Form No. F_012116 Rev 03 April 2023 Page 7 of 7 N4 I Kj® FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com NOTICE: USE ONLY the designated sprinkler wrenches shown in this document. Permanent damage to Athe sprinkler assembly can occur if the proper wrench is not used. Other sprinkler wrenches available from Viking may fit into the sprinkler adapter cup; however, only the wrenches shown here are designed to properly install this sprinkler. Step 1: Remove the protective cap. Step 2: Insert the wrench into the sprinkler adapter. 1 Step 3 Rotate the wrench slightly in either direction until the tines on the wrench (A) line up with the vent openings (B) on the adapter cup and lock into place. NOTE: A leak tight seal must be achieved. Turn the sprinkler clockwise 1 to 1-'/2 turns past finger -tight. B NOTE: Image is representative only. Actual product may vary. Figure 6: Using the Sprinkler Wrench Install the cover plate by inserting the adpater (D) into the adapter cup (C) and pushing or threading into place (depending on style). Snug the cover plate in place _iff by rotating clockwise. Ensure C the cover plate is flush with the ceiling as shown to allow airflow — through the sprinkler assembly. _ D A Minimum Maximum NOTE: Image is representative only. Actual product may vary. Figure 7: Installing the Cover Plate Form No. F_012116 Rev 03 April 2023 Replaces Form No. F_012116 Rev 02 (Replaced wrench 24339 with 23143.) N I KJ NG* (0 Viking Residential Sprinkler Installation Guide October 25, 2018 WARNING: Cancer and Reproductive Harm- www.P65Warnings.ca.gov Trusted Above AIITM www.vikinggroupinc.com Sprinkler RES1 NJ 4 RESIDENTIAL I I a N7G41 111OLFREEDOW SPRINKLERSTALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking residential automatic sprinklers are equipped with a "fast response" heat -sensitive operating element designed to respond individually and quickly to a specific high temperature. Viking residential sprinklers are designed to combine speed of operation with water distribution characteristics to help in the control of residential fires and to improve life safety by prolonging the time available for occupants to escape or be evacuated. 2. LISTINGS AND APPROVALS Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or approval agency listings. A. Viking residential sprinklers are intended for use in the following occupancies: one- and two-family dwellings and mobile homes with the fire protection sprinkler system installed in accordance with NFPA 13D; residential occupancies up to four stories in height with the fire protection system installed in accordance with NFPA 13R; or residential portions of any occupancy with the fire protec- tion system installed in accordance with NFPA 13. Information contained in this guide is based on NFPA 13, "Standard for the Installation of Sprinkler Systems". B. The design criteria for residential sprinklers contained in the NFPA installation standards must be followed except as modified by the individual UL 1626 listing information provided in the technical data pages and this Residential Sprinkler Installation Guide. For listed areas of coverage, technical data, and specific design and installation instructions, refer to the appropriate Viking techni- cal data page for the sprinkler model used. C. Viking residential sprinklers listed by Underwriters Laboratories, Inc. (UL) have passed fire tests designed to represent fire conditions for the sprinkler's listed area of coverage. The standards for residential sprinkler performance and spray patterns are printed in Underwriters Laboratories Publication UL 1626, "Standard for Residential Sprinklers for Fire Protection Service". All listed Viking residential sprinklers meet or exceed UL 1626 performance requirements and spray pattern criteria for their listed areas of coverage. D. NFPA standards allow use of residential sprinklers with rates, design areas, areas of coverage, and minimum design pressures other than those specified in the standards when they have been listed for such specific residential installation conditions. 3. TECHNICAL DATA Specifications: Viking Technical Data may be found on Refer to the appropriate sprinkler technical data sheet. The Viking Corporation's Web site at Material Standards: http://www.vikinggroupinc.com. Refer to the appropriate sprinkler technical data sheet. The Web site may include a more recent edition of this Technical Data Page. 4. INSTALLATION NOTE:Take care not to over -tighten the sprinkler and/or damage its operating parts! Maximum Torque: 1/2" NPT: 14 ft-Ibs. (19.0 N-m) 3/4" NPT: 20 ft-Ibs. (27.1 N-m) A. Care and Handling (also refer to Bulletin - Care and Handling of Sprinklers, Form No. F_091699.) Sprinklers must be handled with care and protected from mechanical damage during storage, transport, handling, and after installation. Store sprinklers in a cool, dry place in their original container. Use care when locating sprinklers near fixtures that can generate heat. Never install sprinklers that have been dropped, damaged in any way, or exposed to temperatures exceeding the maximum ambi- ent temperature allowed (refer to Table 1.) Never install any glass -bulb sprinkler if the bulb is cracked or if there is a loss of liquid from the bulb. A small air bubble should be present in the glass bulb. Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed immediately. (Note: Installing glass bulb sprinklers in direct sunlight (ultraviolet light) may affect the color of the dye used to color code the bulb. This color change does not affect the integrity of the bulb.) Viking residential sprinklers are intended for use on wet pipe residential systems only. Adequate heat must be provided for wet - pipe systems. DO NOT use Viking residential sprinklers on dry systems unless specifically allowed by recognized installation standards or the Authority Having Jurisdiction. Residential concealed sprinklers must be installed in neutral or negative pressure plenums only! Corrosion -resistant sprinklers must be installed when subject to corrosive atmospheres. NOTE: Viking residential sprinklers are not intended for use in corrosive environments. Replaces pages 1-17, dated December 1, 2016. Form No. F 080190 18.10.25 Rev 16.1.P65 (Added P65 Warning.) Sprinkler RES2 N4 I Kj 77 Jill 7FREEDOW RESIDENTIAL SPRINKLER STALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: RESIDENTIAL SPRINKLER TEMPERATURE RATINGS Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature3 Residential Glass Bulb Style Sprinklers Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Sprinkler Temperature Sprinkler Nominal Temperature Maximum Ambient Classification Rating (Fusing Point)' Ceiling Temperature' Residential Fusible Element Style Sprinklers Ordinary 165 °F (74 °C) 100 °F (38 °C) Sprinkler Temperature Sprinkler Nominal Temperature Maximum Ambient Temperature Classification Rating (Fusing Point) Ceiling Temperature Identification Stamp Residential Flush Style Sprinklers Ordinary 165 °F (74 °C) 100 °F (38 °C) On Cover or Sprinkler Inlet (VK476) Intermediate 220 °F (104 °C) 150 °F (65 °C) On Cover Sprinkler Temperature Sprinkler Nominal Temperature Maximum Ambient Cover Plate Temperature Classification Rating (Fusing Point) Ceiling Temperature Rating Residential Concealed Style Sprinklers Ordinary 135 °F (57 °C)', 140 °F (60 °C)2, 100 °F (38 °C) 135 °F (57 °C) 155 °F (68 °C)', or 165 °F Footnotes The sprinkler temperature rating is stamped on the deflector or flow shaper. 2 The temperature rating is stamped on the sprinkler. s Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. B. Installation Instructions Viking sprinklers are manufactured and tested to meet the rigid requirements of approving agencies. They are designed to be installed in accordance with recognized installation standards NFPA 13, NFPA 13R, and NFPA 13D, and any associated TIAs. Deviation from the standards or any alteration to the sprinklers or cover plate assemblies after they leave the factory including, but not limited to: painting, plating, coating, or modification, may render the sprinklers inoperative and will automatically nullify the approval and any guarantee made by Viking. The use of residential sprinklers may be limited due to occupancy and hazard. Residential fire protection systems must be designed and installed only by those who are completely familiar with the appropriate standards and codes, and thoroughly experienced in fire protection design, hydraulic calculations, and sprinkler system installation. Before installation, be sure to have the appropriate sprinkler model and style, with the correct K-Factor, temperature rating, and response characteristics. Viking residential sprinklers must be installed after the piping is in place to prevent mechanical damage. Keep sprinklers with protective caps or bulb shields contained within the caps or shields during installation and testing, and any time the sprinkler is shipped or handled. 1 a. For frame -style sprinklers, install escutcheon (if used), which is designed to thread onto the external threads of the sprinkler*. *Refer to the appropriate sprinkler technical data page to determine approved escutcheons for use with specific sprinkler models. 1b. For flush and concealed style sprinklers: Cut the sprinkler nipple so that the'/2" or 3/4" (15 mm or 20 mm) NPT** outlet of the reducing coupling is at the desired location and centered in the opening** in the ceiling or wall. **Size depends on the sprinkler model used. Refer to appropriate sprinkler data page. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES3 NJ 4 RESIDENTIAL I I a N7G41 IMMUFREEDOW SPRINKLERSTALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA For Systems Designed to NFPA 13D or NFPA 13R: Apply the listed areas of coverage and minimum water supply requirements shown in the approval charts on the residential sprinkler data pages. The sprinkler flow rate is the minimum required discharge from each of the total number of design sprinklers as specified in NFPA 13D or NFPA 13R. For Systems Designed to the latest edition of NFPA 13: The number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the approval charts on the data pages for NFPA 13D and NFPA13R for each area of coverage listed, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. The greatest dimension of the coverage area cannot be any greater than the maximum areas of coverage shown on the data pages. Flow Rates All residential sprinklers manufactured on or after July 12, 2002 are listed with a single minimum flow rate. Where rooms have more than one sprinkler, multiple -sprinkler calculations are still required, but the first sprinkler and any additional sprinkler or sprinklers must be calculated flowing at identical mini- mum flow rates, based on the area of sprinkler coverage, using the minimum flow and pressure listed for the sprinkler model used. Consult the appropriate standards and the Authorities Having Jurisdiction to determine the number of sprinklers to hydraulically calculate to verify ad- equate water supply for multiple -sprinkler operation. Operating Pressure: The minimum operating pressure of any sprinkler shall be the minimum operating pressure specified by the listing, or 7 psi (0.5 bar), whichever is greater. The maximum allowable operating pressure is 175 psi (12 bar). Areas of Coveraae If the actual area of coverage is less than the listed area of coverage, use the minimum water supply for the next larger area of coverage listed. DO NOT interpolate. Residential sprinkler systems must be hydraulically calculated according to NFPA standards to verify that the water supply is adequate for proper operation of the sprinklers. Hydraulic calculations are required to verify adequate water supply at the hydraulically most remote single sprinkler when it is operating at the minimum gpm and psi listed for single -sprinkler operation for the sprinkler model used. Viking residential sprinklers may be listed for more than one area of coverage. Suggested practice in selecting area of coverage is to select the one that can be adequately supplied by the available water supply and still allow for the installation of as few sprinklers in a compartment as possible while observing all guidelines pertaining to obstructions and spacing. This maximizes the use of the available water supply, which is often limited on residential fire protection systems. After selecting an appropriate area of coverage, sprinklers must be spaced according to guidelines set forth in the installation standards. Definition of "COMPARTMENT": A space completely enclosed by walls and a ceiling. Openings to an adjoining space are allowed, provided the open- ings have a minimum lintel depth of 8 in. (203.2 mm) from the ceiling. Saacina Guidelines For guidelines concerning spacing of Viking residential sprinklers near beams, obstructions, heat sources, and sloped ceilings [slopes more than a 2/12 (9.5°) pitch], refer to the Viking residential sprinkler data pages and installation guide, the appropriate NFPA standard, and the Authority Having Jurisdiction. NOTE: Sloped, beamed, and pitched ceilings could require special design features such as larger flow, or a design for more sprinklers to operate in the compartment, or both. Distance from Walls: Install not more than one-half the listed sprinkler spacing nor less than 4" (102 mm) from walls, partitions, or obstructions as defined in the standards. Minimum Sprinkler Spacing: The minimum distance between residential sprinklers to prevent cold soldering (i.e., the spray from one operating sprink- ler onto an adjacent sprinkler that could prevent its proper activation) is 8 ft. (2.4 m). Maximum Sprinkler Spacing: Locate adjacent sprinklers no farther apart than the listed spacing. Deflector Position: Install frame style residential pendent sprinklers with the deflector between 1" and 4" (25.4 mm to 102 mm) below smooth ceilings, unless the sprinkler data page indicates otherwise. Install pendent sprinklers in the pendent position only, with the deflector oriented parallel with the ceiling or roof. Refer to the individual listings in the residential sprinkler data pages for horizontal sidewall sprinkler deflector or sprinkler centerline distance below the ceiling. Install horizontal sidewall sprinklers in the horizontal position only below smooth ceilings, with the leading edge of the deflector or element assembly oriented parallel with the ceiling. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to the ap- propriate sprinkler data page. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES4 Jill 7FREEDOM@ RESIDENTIAL A SPRINKLER STALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 2. Apply a small amount of pipe -joint compound or tape to the external threads of the sprinkler only, taking care not to allow a build-up of compound in the sprinkler inlet. NOTE: Sprinklers with protective caps or bulb shields must be contained within the caps or shields before applying pipe -joint compound or tape. Exception: For concealed sprinklers (i.e., VK457, VK458, VK468, VK474, and VK4570) the protective cap is removed for installation. 3. Care must be taken when installing sprinklers on CPVC and copper piping systems. Never install the sprinkler into the re- ducing fitting before attaching the reducing fitting to the piping. Sprinklers must be installed on CPVC systems after the reducing fitting has been installed and the primer and/or cement manufacturer's recommended curing time has elapsed. When installing sprinklers on copper piping systems, take care to brush the inside of the sprinkler supply piping and reducing fitting to ensure that no flux accumulates in the sprinkler orifice. Excess flux can cause corrosion and may impair the ability of the sprinkler to operate properly. 4. Refer to the appropriate sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. DO NOT use the sprinkler deflector or fusible element to start or thread the sprinkler into a fitting. a. Install the sprinkler onto the piping using the special sprinkler wrench only, while taking care not to over -tighten or damage the sprinkler operating parts. b. Thread the flush or concealed sprinkler into the %" or 3/4" (15 mm or 20 mm) NPT** outlet of the coupling by turning it clock- wise with the special sprinkler wrench. NOTE: For flush and concealed sprinklers with protective shells, the internal diameter of the special flush and concealed sprinkler installation wrench is designed for use with the sprinkler contained within the shell. Exception: For concealed sprinklers VK457, VK458, VK468, VK474, and VK4570 the protective cap is removed for installation, and then placed back on the sprinkler temporarily. 5. After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the installation standards. a. Make sure the sprinkler has been properly tightened. If a thread leak occurs, normally the unit must be removed, new pipe -joint compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal leaks, the sealing compound is washed out of the joint. b. Remove plastic protective sprinkler caps or bulb shields AFTER the wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating ele- ments. To remove the bulb shields, simply pull the ends of the shields apart where they are snapped together. To remove caps from frame style sprinklers, turn the caps slightly and pull them off the sprinklers. SPRINKLER CAPS OR BULB SHIELDS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Retain a protective cap or shield in the spare sprinkler cabinet. 6. For residential flush sprinklers, the ceiling ring can now be installed onto the sprinkler body. Align the ceiling ring with the sprin- kler body and thread on or push it on until the flange touches the ceiling. Note the maximum vertical adjustment is ''/z" (12,7 mm) for sprinkler VK420 and 5/8" for VK476. DO NOT MODIFY THE UNIT. If necessary, re -cut the sprinkler drop nipples as required. 7. For residential concealed sprinklers, the cover plate assembly can now be attached. a. Remove the cover plate assembly from the protective box, taking care not to damage the assembly. b. From below the ceiling, gently place the base of the cover plate assembly over the sprinkler protruding through the opening in the ceiling or wall. c. Carefully push the cover plate assembly onto the sprinkler, using even pressure with the palm of the hand, until the unfinished brass flange of the cover plate base touches the ceiling or wall. d. The maximum adjustment available for residential concealed sprinklers is M." (12.7 mm) [1/4" (6.4 mm) for sprinkler VK480]. DO NOT MODIFY THE UNIT. If necessary, re -cut the sprinkler nipples. NOTE: If it is necessary to remove the entire sprinkler unit, the system must be taken out of service. See Maintenance instructions below and follow all warnings and instructions. 5. OPERATION During fire conditions, the operating element fuses or shatters (depending on the type of sprinkler), releasing the pip cap and seal- ing assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector or flow shaper, forming a uniform, high -wall wetting spray pattern to extinguish or control the fire. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES5 NJ 4 RESIDENTIAL I I a N7G41 111OLFREEDOW SPRINKLERSTALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. NOTICE: The owner is responsible for having the fire - protection system and devices inspected, tested, and maintained in proper operating condition in accordance with this guide, and applicable NFPA standards. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. A. Sprinklers must be inspected on a regular basis for signs of corrosion, mechanical damage, obstructions, paint, etc. Frequency of the inspections may vary due to corrosive atmospheres, water supplies, and activity around the device. B. Sprinklers or cover plate assemblies that have been field painted, caulked, or mechanically damaged must be replaced im- mediately. Sprinklers showing signs of corrosion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested and, if necessary, replaced immediately after a specified term of service. Refer to NFPA 25 and the Authorities Having Jurisdiction for the specified period of time after which testing and/or replacement of residential sprinklers is required. Never attempt to repair or reassemble a sprinkler. Sprinklers and cover assemblies that have operated cannot be reassembled or re -used, but must be replaced. When replacement is necessary, use only new sprinklers and cover assemblies with identical performance characteristics. C. The sprinkler discharge pattern is critical for proper fire protection. Nothing should be hung from, attached to, or otherwise ob- struct the discharge pattern of the sprinkler. All obstructions must be immediately removed or, if necessary, additional sprinklers installed. D. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the effected area. 1. Remove the system from service, drain all water, and relieve all pressure on the piping. 2a. For frame -style sprinklers, use the special sprinkler wrench and remove the old sprinkler by turning it counterclockwise to unthread it from the piping. 2b. Forresidentialflushpendentandconcea/edstyle sprinklers: Remove the ceilingring orcoverplate assemblybefore unthreading the sprinkler body from the piping. To remove a ceiling ring, grasp it from below the ceiling and gently turn it counterclockwise. Cover plates can be removedeitherbygentlyunthreading them orpulling them offthe sprinklerbody(dependson the sprinklermodel used). After the ceiling ring or cover plate assembly has been removed from the sprinkler, use the sprinkler wrench to unthread the sprinkler from the piping. NOTE: For flush and concealed sprinklers with protective shells, the internal diameter of the special flush and concealed sprinkler installation wrench is designed for use with the sprinkler contained within the shell. Place a plastic protective shell (from the spare sprinkler cabinet) over the sprinkler to be removed and then fit the sprinkler wrench over the shell. Exception: Concealed sprinklers VK457, VK458, VK468, VK474, and VK4570 are removed without the plastic cap. 3. Follow instructions in section 4B. Installation Instructions to install the new unit. Be sure the replacement sprinkler is the correct model and style, with the appropriate K-Factor, temperature rating, and response characteristics. A fully stocked sprinkler cabinet should be provided for this purpose. (For flush or concealed style sprinklers, stock of spare ceiling rings or cover plates should also be available in the spare sprinkler cabinet.) 4. Place the system back in service and secure all valves. Check for and repair all leaks. E. Sprinkler systems that have been subjected to a fire must be returned to service as soon as possible. The entire system must be inspected for damage, and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion or high ambient temperatures, but have not operated, should be replaced. Refer to the Authority Having Jurisdiction for minimum replacement requirements. 7. AVAILABILITY Viking Residential Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES6 N4 I Kj 77 Jill 7FREEDOM@ RESIDENTIAL SPRINKLER STALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com S� I? `A ❑PP❑SITE �y SIDE ADJACENT SIDE TANGENT = ❑PP❑SITE SIDE (RISE) ADJACENT SIDE (RUN) RISE = TANGENT RUN ANGLE = TAN-1 RIS RUN SLOPE DISTANCE=./(RISE5+ (RUN)' RISE RUN ANGLE SLOPE RISE RUN TANGENT ANGLE DISTANC 2 12 .1666 9,45° 12.1 3 12 .2500 14° 12.3 4 12 .3333 18.4° 12.6 5 12 .4166 22,6° 13 6 12 .5000 26,5° 13.4 7 12 .5833 30,2° 13.8 8 12 .6666 33,6° 14.4 9 12 .7500 36,8° 15 10 12 .8333 39,8° 15.6 11 12 .9166 42,5° 16.2 12 12 1 45° 16.97 Table 2 Rise Over Run Conversion to Degrees of Slope Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES7 NJ 4 RESIDENTIAL I I a N7G41 IMMOLFREEDOM@ SPRINKLERSTALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com SPACING OF RESIDENTIAL SPRINKLERS LISTED FOR USE BELOW SLOPED CEILINGS UP TO AN 8/12 (33.70) PITCH (Refer to the appropriate residential sprinkler technical data page for listings.) Pendent Sprinklers Horizontal Sidewall Sprinklers (Spray Across the Slope) Figure 1 (A) One-half listed spacing of sprinkler maximum, 0'-4" (0-102 mm) minimum. (B) Listed spacing of sprinkler, maximum, 8'-0" (2.4 m) minimum. (C) Where angle "C" is greater than an 8/12 (33.7°) pitch, see Figure 2 below. SPACING OF RESIDENTIAL SPRINKLERS BELOW SLOPED CEILINGS WITH GREATER THAN 8/12 (33.7°) PITCH (NOTE: Refer to NFPA 13D or NFPA 13R, and the Authority Having Jurisdiction.) )le Slope Figure 2 (A) One-half listed spacing of sprinkler, maximum. (B) T-0" (.91 m) maximum. (C) 0'-4" (0-102 mm) minimum. (D) Slopes greater than an 8/12 (33.7°) pitch. (E) For distance less than 8'-0" (2.4 m), baffle required. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES8 N4 I Kj 77 Jill 7FREEDOM@ RESIDENTIAL SPRINKLER STALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com SPACING OF RESIDENTIAL SPRINKLERS LISTED FOR USE BELOW SLOPED CEILINGS UP TO AN 8/12 (33.7°) PITCH (Refer to the appropriate residential sprinkler technical data page for listings.) venaent sprinKiers Figure 3 morizontai siaewan sprinKiers (Spray Across the Slope) (A) One-half listed spacing of sprinkler, maximum (B) 8'-0" (2.4 m) minimum. (C) 0'-4" (0-102 mm) minimum. (D) 3'-0" (.91 m) maximum. (E) Acceptable for slopes of 0/12 to 8/12 (0' to 33.7°) pitch. SPACING OF RESIDENTIAL PENDENT SPRINKLERS AT PEAK OF SLOPED CEILINGS WITH PITCH LESS THAN8/12 (�33.7°) (Refer to the appropriate residential sprinkler technical da a page for listings.) ,pe Figure 4 (A) Listed spacing of sprinkler, maximum. (B) One-half listed spacing of sprinkler, maximum. (C) 0'-4" minimum. (D) Refer to page 10 for minimum distance between sprinkler and intersecting sloped ceiling. (E) Refer to the appropriate residential sprinkler technical data page for deflector distance below ceiling. (F) 8'-0" minimum. (G)Reference: 4/12 (18.0°) pitch maximum for 12' (3.7 m) spacing. 2.5/12 (12.0°) pitch maximum for 14' (4.3 m) spacing. 2/12 (10.0°) pitch maximum for 16' (4.9 m) spacing. 2/12 (10.0°) pitch maximum for 18' (5.5 m) spacing. 1.9/12 (9.0°) pitch maximum for 20' (6.1 m) spacing. Angles based on sprinklers installed 0'-4" (0-102 mm) from peak. NOTE: Whenever possible, utilize design as shown in Figure 3 above. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES9 NJ 4 RESIDENTIAL I I a N7G41 111OLFREEDOM@ SPRINKLERSTALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com SPACING OF RESIDENTIAL SPRINKLERS BELOW SLOPED CEILINGS WITH GREATER THAN 8/12 (33.7°PITCH WITH NO BAFFLE AND A MAXIMUM OF 2 SPRINKLERS IN THE ROOM (NOTE: Refer to NFPA 13D or NFPA 13R, and the Authority Having Jurisdiction.) Aultiple Slope ,_. -- - (A) One-half listed spacing of sprinkler, maximum. (B) 8'-0" (2.4 m) minimum. (C) 0'-4" (0-102 mm) minimum. (D) T-0" (.91 m) maximum. (E) Acceptable for slopes greater than an 8/12 (33.7°) pitch. (F) When this design is used, refer to the appendices of NFPA 13D or NFPA 13R, and the Authority Having Jurisdiction regarding the number of design sprinklers to hydraulically calculate. SPACING OF RESIDENTIAL SPRINKLERS BELOW CEILINGS WITH SLOPES EXCEEDING 8/12 (33.7°) PITCH WITH NO BAFFLE AND A MAXIMUM OF 3 SPRINKLERS IN THE ROOM (NOTE: Refer to NFPA 13D or NFPA 13R, and the Authority Having Jurisdiction.) tiple Slope Flume v (A) 0'-4" (0-102 mm) minimum, to one-half listed spacing, maximum. (B) One-half listed spacing, maximum, 8'-0" (2.4 m) minimum. (C) 0'-4" (0-102 mm) minimum. (D) Listed spacing maximum, 8'-0" (2.4 m) minimum. (E) T-0" (.91 m) maximum. (F) Slopes greater than 8/12 up to a 21/12 (33.7° up to 60°) pitch. NOTES: In addition to the above limits, rooms requiring this type of installation must be hydraulically cal- culated to supply a minimum of three operating sprinklers. Layout similar for horizontal sidewall sprinklers with throw across slope. Refer to the appropriate residential sprinkler technical data sheets. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES10 N4 I Kj 77 Jill 7FREEDOM@ RESIDENTIAL SPRINKLER STALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com SPACING OF RESIDENTIAL SPRINKLERS BELOW CEILINGS WITH SLOPES EXCEEDING 8/12 (33.70) PITCH WITH NO BAFFLE AND A MAXIMUM OF 2 SPRINKLERS IN THE ROOM (NOTE: Refer to NFPA 13D or NFPA 13R, and the Authority Having Jurisdiction.) iltiple Slope Figure 7 (A) 0'-4" (0-102 mm) minimum, to one-half listed spacing, maximum. (B) One-half listed spacing, maximum, 8'-0" (2.4 m) minimum. (C) 0'-4" (0-102 mm) minimum. (D)Slopes greater than 8/12 pitch up to a 21/12 (33.7° up to a 60°) pitch. (E) 3'-0" (.91 m) maximum. (F) When dimension "F" exceeds 16' (4.9 m), utilize design configuration shown in Figure 6. NOTES: Layout similar for horizontal sidewall sprinklers with throw across slope. Refer to the appropriate residential sprinkler technical data sheets. Multiple Slope Multiple Slope Figure 8 Single Slope (A) One-half listed spacing, maximum. (B) Refer to the appropriate residential sprinkler technical data pages for listings of sprinklers for use below slopes up to and including a 8/12 (33.7°) pitch. (C) 3'-0" (.91 m) maximum. (D) 0'-4" (0-102 mm) minimum. (E) 8'-0" (2.4 m) minimum without baffle. NOTES: Layout similar for horizontal sidewall sprinklers with throw across slope. Refer to the appropriate residential sprinkler technical data sheets. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES11 FREEDOM° RESIDENTIAL TECHNICAL DATA N11UNG4 SPRINKLER INSTALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com MINIMUM DISTANCE BETWEEN SPRINKLER AND INTERSECTING SLOPED CEILINGS 4' (1.2 m) d 3'-6" (1.06 m a 0 co 3' (.91 m) A B = w 2'-6" (.76 m d u C 16 0 2' (.61 m) E 3 E NOTES: For any ceiling slope under 7/12 (30°), 1'-6" (.46 m distribution is considered Not Unduly Obstructed. 1' (305 mm) 20' (6.1 m) 18' (5.5 m) d d 16'(4.9m) v d 14' (4.3 m) D, 12' (3.7 m) a JV JJ TV �J (B) Slope of Ceiling (degrees) 12/12 (inches) MAXIMUM DISTANCE DOWN SLOPE TO AVOID OBSTRUCTION TO SPRINKLER DISCHARGE 7 A B 12(3.7 m) 10' (3.05 m) m d rn 8' (2.4 m) _ 3 0 6' (1.8 m) C l6 Vl 0 4'(1.2m) 2' (.61 m) raw NOT UNDULY OBSTRUCTED OBSTRUCTED 20' (6.1 m) d w 18'(5.5m) _ 16'(4.9m) Z cc 14' (4.3 m) Y _ 12'(3.7m)'Q U) E 3 E R 2 0 5 10 15 20 25 30 35 40 45 (B) Slope of Ceiling (degrees) Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES12 N4 I Kj 77 Jill 7FREEDOM@ RESIDENTIAL SPRINKLER STALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com AVOIDING OBSTRUCTIONS TO SPRINKLER DISCHARGE (Obstruction rules for residential sprinklers are found in section 8.10 of the 2010 edition of NFPA 13.) Positioning Residential Pendent Sprinklers - Obstructions at the Ceiling LJ I a I -•- A Maximum Distance from Distance from Sprinkler Deflector to Bottom of Ceiling to Side of Ceiling Obstruction (Dimension B) Inches mm Obstruction (Dimension A) Less than 1 ft. 6 in. 0 0 (Less than 457 mm) 1 ft. 6 in. to less than 3 ft. 1 25.4 (457 mm to less than .94 m) 3 ft. to less than 4 ft. 3 76 (.91 m to less than 1.2 m) 4 ft. to less than 4 ft. 6 in. 5 127 (1.2 m to less than 1.37 m) 4 ft. 6 in. to less than 6 ft. 7 178 (1.37 m to less than 1.8 m) 6 ft. to less than 6 ft. 6 in. 9 229 (1.8 m to less than 2 m) 6 ft. 6 in. to less than 7 ft. 11 279 (2 m to less than 2.1 m) 7 ft. or greater 14 356 (2.1 m or greater) Residential pendent sprinklers may be located on opposite sides of continuous obstructions up to 4 ft. (1.2 m) wide at the 4' Max. ceiling, as long as the distance from the centerline of the obstruction to the sprinklers (A) does not exceed one-half the maximum A A spacing allowed between sprinklers. Positioning Residential Pendent Sprinklers - Obstructions Along Walls (A) Distance from centerline of sprinkler to side of obstruction. (B) Distance from deflector to bottom of obstruction. B (C) Width of the obstruction. Obstructions up to 30 in. (.8 m) wide (C) located against the wall are permitted C to be protected when (A) is greater than A or equal to (C) minus 8 in. (.2 m) plus (B). C < 30 in. for metric C < .8 m A>(C-8in.)+B A>(C-.2m)+B Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES13 NJ 4 RESIDENTIAL I I a N7G41 111OLFREEDOW SPRINKLERSTALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com AVOIDING OBSTRUCTIONS TO SPRINKLER DISCHARGE (Obstruction rules for residential sprinklers are found in section 8.10 of the 2010 edition of NFPA 13.) Positioning Residential Horizontal Sidewall Sprinklers - Obstructions at the Ceiling Ceiling or Roof. B Obstruction A Wall (A) Distance from sprinkler to side of obstruction. (B) Distance from deflector to bottom of obstruction. Distance from Sprinkler to Maximum Distance from Deflector to Bottom of Ceiling Obstruction Side of Ceiling Obstruction (Dimension B) (Dimension A) Inches mm Less than 8 ft. No Obstructions Allowed (Less than 2.4 m) 8 ft. to less than 10 ft. 1 25.4 (2.4 m to less than 3.05 m) 10 ft. to less than 11 ft. 2 50.8 (3.05 m to less than 3.35 m) 11 ft. to less than 12 ft. 3 76 (3.35 m to less than 3.7 m) 12 ft. to less than 13 ft. 4 102 (3.7 m to less than 4 m) 13 ft. to less than 14 ft. 6 152 (4 m to less than 4.3 m) 14 ft. to less than 15 ft. 7 178 (4.3 m to less than 4.6 m) 15 ft. to less than 16 ft. g 229 (4.6 m to less than 4.9 m) 16 ft. to less than 17 ft. 11 279 (4.9 m to less than 5.2 m) 17 ft. or greater 14 356 (5.2 m or greater) Positioning Residential Horizontal Sidewall Sprinklers - Obstructions Along Walls A j e Distance from Sprinkler to Maximum Distance from Deflector to Bottom of Side of Obstruction Along Obstruction (Dimension B) Wall (Dimension A) Inches mm Less than 1 ft. 6 in. 0 0 (Less than 457 mm) 1 ft. 6 in. to less than 3 ft. 1 25.4 (457 mm to less than .94 m) 3 ft. to less than 4 ft. 3 76 (.91 m to less than 1.2 m) 4 ft. to less than 4 ft. 6 in. 5 127 (1.2 m to less than 1.37 m) 4 ft. 6 in. to less than 6 ft. 7 178 (1.37 m to less than 1.8 m) 6 ft. to less than 6 ft. 6 in. 9 229 (1.8 m to less than 2 m) 6 ft. 6 in. to less than 7 ft. 11 279 (2 m to less than 2.1 m) 7 ft. or greater 14 356 (2.1 m or greater) (A) Distance from sprinkler to side of obstruction. Form No. F 080190 18.10.25 Rev 16.1.P65 (B) Distance from deflector to bottom of obstruction. Sprinkler RES14 Jill 7FREEDOM@ RESIDENTIAL A SPRINKLER STALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com LOCATING RESIDENTIAL SPRINKLERS NEAR HEAT SOURCES Ordinary temperature rated residential sprinklers (135 °F to 170 °F rated) are only to be installed where the maximum ambient ceiling temperature will not exceed 100 'F. Where the maximum ambient ceiling temperature will be from 101 °F to 150 °F, use intermediate temperature rated residential sprinklers (175 °F to 225 °F rated). Residential sprinklers must be positioned a sufficient distance away from heat sources that include fireplaces, stoves, kitchen ranges, wall ovens, hot water pipes, water heaters, furnaces and associated flues and ducts, and light fixtures. The following minimum distances must be maintained for both ordinary and intermediate temperature rated residential sprinklers as indicated. Heat Source Minimum Distance from Edge of Source to Ordinary Temperature Rated Sprinkler Minimum Distance from Edge of Source to Intermediate Temperature Rated Sprinkler Inches metric Inches metric Side of open or recessed fireplace 36 .91 m 12 305 mm Front of recessed fire place 60 1.5 m 36 .91 m Coal- or wood -burning stove 42 1.1 m 12 305 mm Kitchen range 18 457 mm 9 229 mm Wall oven 18 457 mm 9 229 mm Hot air flues 18 457 mm 9 229 mm Uninsulated heat ducts 18 457 mm 9 229 mm Uninsulated hot water pipes 12 305 mm 6 152 mm Side of ceiling- or wall -mounted hot air diffusers 24 .61 m 12 305 mm Front of wall -mounted hot air diffusers 36 .91 m 18 457 mm Hot water heater or furnace 6 152 mm 3 76 mm Light fixture less than 250W 6 152 mm 3 76 mm Light fixture 250W to 499W 12 305 mm 6 152 mm Where residential sprinklers will be exposed to the rays of the sun passing through glass or plastic skylights, use inter- mediate temperature rated sprinklers. When locating residential sprinklers in an unventilated concealed compartment, under an unventilated attic or unin- sulated roof, where the maximum ambient temperature does not exceed 150 °F, use intermediate temperature rated sprinklers. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES15 NJ 4 7FREEDOM@ RESIDENTIAL I IU A A A SPRINKLERSTALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com NOTE: The dimensions shown are intended to apply to residential sprinklers installed in ceilings above fireplaces used to burn products that cause elevated temperatures at or near the ceiling in areas surrounding the fireplace. The recommendations should not be construed to apply to decorative non -opening fireplaces such as gas fire units that will not cause elevated temperatures at the ceiling. Top View Sprinklers near an open hearth fireplace must be located outside of the shaded area or be intermediate degree rated. Top View Side of fireplace Front of fireplace Front Vi( ...................... ..................... .................... ................... ................. . 5'-0" (1.5 m) LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL iw LLLLLLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLLLLLL LLL LL LLL LL LLLL LL LLL LL LLL LL LLL LL LLL LL LLL LL L L L L X-0" (.91 m) Sprinklers near a recessed hearth fireplace must be located outside of the shaded area [at least T-0" (.91 m)] from the side of a recessed fireplace and at least 5-0" (1.5 m) from the front) or be intermediate degree rated. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES16 N4 7FREEDOM° RESIDENTIAL 4 I KiA SPRINKLERSTALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1'-6" (457 mm) TYP Top View ....... ...................� 2'-6" (.8 m) TYP 0 ................... ................... ................... 0 ................... o� 1'-6" (457 mm) TYP 0 ......................................., Front View F I o F-1 Sprinklers near a furnace or water heater must be located outside of the shaded area or be intermediate degree rated. Top View Edge of coal- or wood -burning stove Edge of coal- or wood -burning stove Front Vi( 3'-6" (1.1 m) 3'-6" (1.1 m) 3'-6" (1.1 m) Sprinklers near a coal- or wood -burning stove must be located outside of shaded area or be intermediate degree rated. Form No. F_080190 18.10.25 Rev 16.1.P65 Sprinkler RES17 NJ 4 RESIDENTIAL I I a N7G41 111OLFREEDOW SPRINKLERSTALLATION GUIDE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Top View (457 mm) ILL.LLL.LLILILILILILILILILLLLLLLLLL LLLLLLLLL LLLLLLLLL LLLLLLLLL Front View LLLLLLLLL L 0 tLLL , - L L L LLL L LL Sprinklers near a range or wall oven must be located outside of shaded areas or be intermediate degree rated. Replaces pages 1-17, dated December 1, 2016. Form No. F 080190 18.10.25 Rev 16.1.P65 (Added P65 Warning.) Page 1 of 4 CARE AND HANDLING 7W74j] 1111 OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com SPRINKLERS ARE FRAGILE - HANDLE WITH CARE! General Handling and Storage: • Store sprinklers in a cool, dry place. • Protect sprinklers during storage, transport, handling, and after installation. • Use the original shipping containers. DO NOT place sprinklers loose in boxes, bins, or buckets. • Keep sprinklers separated at all times. DO NOT allow metal parts to contact sprinkler operating elements. For Pre -Assembled Drops: • Protect sprinklers during handling and after installation. • For recessed assemblies, use the protective sprinkler cap (Viking Part Number 10364). Sprinklers with Protective Shields or Caps: • DO NOT remove shields or caps until after sprinkler installation and there no longer is potential for mechanical damage to the sprinkler operating elements. • Sprinkler shields or caps MUST be removed BEFORE placing the system in service! • Remove the sprinkler shield by carefully pulling it apart where it is snapped together. • Remove the cap by turning it slightly and pulling it off the sprinkler. Sprinkler Installation: • DO NOT use the sprinkler deflector or operating element to start or thread the sprinkler into a fitting. • Use only the designated sprinkler head wrench! Refer to the current sprinkler tech- nical data page to determine the correct wrench for the model of sprinkler used. • DO NOT install sprinklers onto piping at the floor level. • Install sprinklers after the piping is in place to prevent mechanical damage. • DO NOT allow impacts such as hammer blows directly to sprinklers or to fittings, pipe, or couplings in close proximity to sprinklers. Sprinklers can be damaged from direct or indirect impacts. • DO NOT attempt to remove drywall, paint, etc., from sprinklers. • Take care not to over -tighten the sprinkler and/or damage its operating parts! Maximum Torque: 1/2" NPT: 14 ft-Ibs. (19.0 N-m) 3/4" NPT: 20 ft-Ibs. (27.1 N-m) 1" NPT. 30 ft-Ibs. (40.7 N-m) CORRECT INCORRECT (Original container used) (Placed loose in box) CORRECT INCORRECT (Protected with caps) (Protective caps not used) CORRECT INCORRECT (Piping is in place at the (Sprinkler at floor level) ceiling) (Special installation (Designated wrench not wrenches) used) WARNING: Cancer and Reproductive Harm- www. P65Warn ings. ca.gov Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature allowed. Sprinklers that have been painted in the field must be replaced per NFPA 13. Protect sprinklers from paint and paint overspray in accordance with the installation standards. Do not clean sprinklers with soap and water, ammonia, or any other cleaning fluid. Do not use adhesives or solvents on sprinklers or their operating elements. Refer to the appropriate technical data page and NFPA standards for complete care, handling, installation, and maintenance instructions. For additional product and system information Viking data pages and installation instructions are available on the Viking Web site at www.vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) Page 2 of 4 CARE AND HANDLING 7W74J] 1111 OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com PROTECTIVE SPRINKLER SHIELDS AND CAPS General Handling and Storage: Many Viking sprinklers are available with a plastic protective cap or shield temporarily covering the operating elements. The snap - on shields and caps are factory installed and are intended to help protect the operating elements from mechanical damage during shipping, storage, and installation. NOTE: It is still necessary to follow the care and handling instructions on the appropriate sprin- kler technical data sheets* when installing sprinklers with bulb shields or caps. WHEN TO REMOVE THE SHIELDS AND CAPS: NOTE: SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Remove the shield or cap from the sprinkler only after checking all of the following: The sprinkler has been installed'. The wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operating elements. SHIELDS AND CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! ply, ' •.�. Figure 1: Sprinkler shield being removed from a pendent sprinkler Figure 2: Sprinkler cap being removed from a pendent sprinkler. Figure 3: Sprinkler cap being re- moved from and upright sprinkler. HOW TO REMOVE SHIELDS AND CAPS: No tools are necessary to remove the shields or caps from sprinklers. DO NOT use any sharp objects to remove them! Take care not to cause mechanical damage to sprinklers when removing the shields or caps. When removing caps from fusible ele- ment sprinklers, use care to prevent dislodging ejector springs or damaging fusible elements. NOTE: Squeezing the sprinkler cap excessively could damage sprinkler fusible elements. • To remove the shield, simply pull the ends of the shield apart where it is snapped together. Refer to Figure 1. • To remove the cap, turn it slightly and pull it off the sprinkler. Refer to Figures 2 and 3. REMRefer to the current sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. ©WARNING Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambient temperature allowed. * Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Figure 1: Sprinkler shield being removed from a pendent sprinkler Figure 2: Sprinkler cap being removed from a pendent sprinkler. Figure 3: Sprinkler cap being re- moved from and upright sprinkler. HOW TO REMOVE SHIELDS AND CAPS: No tools are necessary to remove the shields or caps from sprinklers. DO NOT use any sharp objects to remove them! Take care not to cause mechanical damage to sprinklers when removing the shields or caps. When removing caps from fusible ele- ment sprinklers, use care to prevent dislodging ejector springs or damaging fusible elements. NOTE: Squeezing the sprinkler cap excessively could damage sprinkler fusible elements. • To remove the shield, simply pull the ends of the shield apart where it is snapped together. Refer to Figure 1. • To remove the cap, turn it slightly and pull it off the sprinkler. Refer to Figures 2 and 3. REMRefer to the current sprinkler technical data page to determine the correct sprinkler wrench for the model of sprinkler used. ©WARNING Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambient temperature allowed. * Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Page 3 of 4 U ARE AND HANDLING I KJ N7G*J 0 M OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com ACAUTION CONCEALED COVER ASSEMBLIES ARE FRAGILE! TO ASSURE SATISFACTORY PERFORMANCE OF THE PRODUCT, HANDLE WITH CARE. Concealed Sprinkler and Adapter Assembly (Protective Cap Removed) Concealed Sprinkler and Adapter Assembly with Protective Cap Cover Plate Assembly (Pendent Cover 12381 shown) GENERAL HANDLING AND STORAGE INSTRUCTIONS: • Do not store in temperatures exceeding 100 °F (38 °C). Avoid direct sunlight and confined areas subject to heat. • Protect sprinklers and cover assemblies during storage, transport, handling, and after installation. Use original shipping containers. Do not place sprinklers or cover assemblies loose in boxes, bins, or buckets. • Keep the sprinkler bodies covered with the protective sprinkler cap any time the sprinklers are shipped or handled, during testing of the system, and while ceiling finish work is being completed. • Use only the designated Viking recessed sprinkler wrench (refer to the appropriate sprinkler data page) to install these sprinklers. NOTE: The protective cap is temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed. • Do not over -tighten the sprinklers into fittings during installation. • Do not use the sprinkler deflector to start or thread the sprinklers into fittings during installation. • Do not attempt to remove drywall, paint, etc., from the sprinklers. • Remove the plastic protective cap from the sprinkler before attaching the cover plate assembly. PROTECTIVE CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Page 4 of 4 CARE AND HANDLING 7W74j] 1111 OF SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com USE THE FOLLOWING PRECAUTIONS WHEN HANDLING WAX -COATED SPRINKLERS Many of Viking's sprinklers are available with factory -applied wax coating for corrosion resistance. These sprinklers MUST receive appropriate care and handling to avoid damaging the wax coating and to assure satisfactory performance of the product. General Handling and Storage of Wax -Coated Sprinklers: • Store the sprinklers in a cool, dry place (in temperatures below the maximum ambient temperature allowed for the sprinkler temperature rating. Refer to Table 1 below.) • Store containers of wax -coated sprinklers separate from other sprinklers. • Protect the sprinklers during storage, transport, handling, and after installation. • Use original shipping containers. • Do not place sprinklers in loose boxes, bins, or buckets. Installation of Wax -Coated Sprinklers: Use only the special sprinkler head wrench designed for installing wax -coated Viking sprinklers (any other wrench may damage the unit). • Take care not to crack the wax coating on the units. • For touching up the wax coating after installation, wax is available from Viking in bar form. Refer to Table 1 below. The coating MUST be repaired after sprinkler installation to protect the corrosion -resistant properties of the sprinkler. • Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they would be exposed to temperatures exceed- ing the maximum recommended ambient temperature for the temperature rating used. • Inspect the coated sprinklers frequently soon after installation to verify the integrity of the corrosion resistant coating. Thereafter, inspect representative samples of the coated sprinklers in accordance with NFPA 25. Close up visual inspections are necessary to determine whether the sprinklers are being affected by corrosive conditions. Sprinkler Temperature Rating (Fusing Point) Wax Part Number Wax Melting Point Maximum Ambient Ceiling Temperature Wax Color 155 °F (68 °C) / 165 °F (74 °C) 02568A 148 °F (64 °C) 100 °F (38 °C) Light Brown 175 °F (79 °C) 04146A 161 °F (71 °C) 150 °F (65 °C) Brown 200 °F (93 °C) 04146A 161 °F (71 °C) 150 °F (65 °C) Brown 220 °F (104 °C) 02569A 170 °F (76 °C) 150 °F (65 °C) Dark Brown 286 °F (141 °C) 02569A 170 °F (76 °C) 150 °F (65 °C) Dark Brown Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. ©WARNING Never install sprinklers that have been dropped, damaged, or exposed to temperatures in excess of the maximum ambi- ent temperature allowed. Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com. Form No. F_091699 18.10.11 Rev 16.1.P65 Replaces Form No. F_091699 Rev 16.1 (Added P65 Warning) Page 1 of 3 N4 I KJ 7W74J] 111 i 9 SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking fire sprinklers consist of a threaded frame with a specific waterway or orifice size and a deflector for distributing water in a specified pattern. A closed or sealed sprinkler refers to a complete assembly, including the thermosensitive operating element. An open sprinkler does not use an operating element and is open at all times. The distribution of water is intended to extinguish a fire or to control its spread. Viking sprinklers are available in several models and styles. Refer to specific sprinkler technical data pages for available styles, finishes, temperature ratings, thread sizes, and nominal K-Factors for the particular model selected. 2. LISTINGS AND APPROVALS Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or WARNING: Cancer and Reproductive Harm - approval agency listings. www.P65Warnings.ca.gov 3. TECHNICAL DATA Pressure Ratings: Maximum allowable water working pressure is 175 psig (12 Bar) unless rated and specified for high water working pressure [250 psig (17.2 bar)]. Sprinkler Identification: Viking sprinklers are identified and marked with the word "Viking", the sprinkler identification number (SIN) consisting of "VK" plus a three digit number', the model letter, and the year of manufacture. Available Finishes: Viking sprinklers are available in several decorative finishes. Some models are available with corrosion -resistant coatings or are fabricated from non -corrosive material. Refer to the sprinkler technical data page for additional information. Available Temperature Ratings: Viking sprinklers are available in several temperature ratings that relate to a specific temperature classification. Applicable installa- tion rules mandate the use and limitations of each temperature classification. In selecting the appropriate temperature classifica- tion, the maximum expected ceiling temperature must be known. When there is doubt as to the maximum temperature at the sprinkler location, a maximum -reading thermometer should be used to determine the temperature under conditions that would show the highest readings to be expected. In addition, recognized installation rules may require a higher temperature classifica- tion, depending upon sprinkler location, occupancy classification, commodity classification, storage height, and other hazards. In all cases, the maximum expected ceiling temperature dictates the lowest allowable temperature classification. Sprinklers located immediately adjacent to a heat source may require a higher temperature rating. K-Factors: Viking sprinklers are available in several orifice sizes with related K-Factors. The orifice is a tapered waterway and, therefore, the K-Factor given is nominal. Nominal U.S. K-Factors are provided in accordance with the 1999 edition of NFPA 13, Section 3-2.3. Refer to the specific data page for appropriate K-Factor information. Available Styles: Viking sprinklers are available for installation in several positions as indicated by a stamping on the deflector. The deflector style dictates the appropriate installation position of the sprinkler; it breaks the solid stream of water issuing from the sprinkler orifice to form a specific spray pattern. The following list indicates the various styles and identification of Viking sprinklers. UPRIGHT SPRINKLER: A sprinkler intended to be installed with the deflector above the frame so water flows upward through the orifice, striking the deflector and forming an umbrella -shaped spray pat- tern downward. Marked "SSU" (Standard Sprinkler Upright) or "UPRIGHT" Viking Technical Data may be found on on the deflector. PENDENT SPRINKLER: A sprinkler intended to be oriented with the deflec- The Viking Corporation's Web site at for below the frame so water flows downward through the orifice, striking http://www.vikinggroupinc.com. the deflector and forming an umbrella -shaped spray pattern downward. The Web site may include a more recent Marked "SSP" (Standard Sprinkler Pendent) or "PENDENT" on the de- edition of this Technical Data Page. flector. CONVENTIONAL SPRINKLER: An "old style" sprinkler intended to be installed with the deflector in either the upright or pendent position. The deflector provides a spherical type pattern with 40 to 60 percent of the water initially directed downward and a proportion directed upward. Must be installed in accordance with installation rules for conventional or old style sprinklers. DO NOT USE AS A REPLACEMENT FOR STANDARD SPRAY SPRINKLERS. Marked "C U/P" (Conventional Upright/Pendent) on the deflector. Form No. F_080814 18.12.06 Rev 14.1.P65 Replaces Form No. F_080814 Rev 14.1 (Added P65 Warning.) Page 2 of 3 N4 I KJ 7W74J] 111 i 9 SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com VERTICAL SIDEWALL (VSW) SPRINKLER: A sprinkler intended for installation near the wall and ceiling. The deflector provides a water spray pattern outward in a quarter -spherical pattern and can be installed in the upright or pendent position with the flow arrow in the direction of discharge. Marked "SIDEWALL" on the deflector with an arrow and the word "FLOW". (Note: Some vertical sidewall sprinklers can only be installed in the upright or pendent position —in this case, the sprinkler will also be marked "UPRIGHT" or "PENDENT".) HORIZONTAL SIDEWALL (HSW) SPRINKLER: A sprinkler intended for installation near the wall and ceiling. The special deflector provides a water spray pattern outward in a quarter -spherical pattern. Most of the water is directed away from the nearby wall with a small portion directed at the wall behind the sprinkler. The top of the deflector is oriented parallel with the ceiling or roof. The flow arrows point in the direction of discharge. Marked "SIDEWALL" and "TOP" with an arrow and the word "FLOW". EXTENDED COVERAGE (EC) SPRINKLER: A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listings. Maximum area of coverage, minimum flow rate, orifice size, and nominal K-Factor are specified in the individual listings. EC sprinklers are intended for Light -Hazard occupancies with smooth, flat, horizontal ceil- ings unless otherwise specified. In addition to the above markings, the sprinkler is marked "EC". QUICK RESPONSE (QR) SPRINKLER: A spray sprinkler with a fast- actuating operating element. The use of quick response sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction (AHJ) prior to installing. QUICK RESPONSE EXTENDED COVERAGE (QREC) SPRINKLER: A spray sprinkler designed to discharge water over an area having the maximum dimensions indicated in the individual listing. This is a sprinkler with an operating element that meets the criteria for quick response. QREC sprinklers are only intended for Light Hazard occupancies. The sprinkler is marked "QREC'. FLUSH SPRINKLER: A decorative spray sprinkler intended for installation with a concealed piping system. The unit is mounted flush with the ceiling or wall, with the fusible link exposed. Upon actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked "SSP", "PEND", or "SIDEWALL" and "TOP". CONCEALED SPRINKLER: A decorative spray sprinkler intended for installation with a concealed piping system. The sprinkler is hidden from view by a cover plate installed flush with the ceiling or wall. During fire conditions, the cover plate detaches, and upon sprinkler actuation, the deflector extends beyond the ceiling or wall to distribute water discharge. The sprinkler is marked "SSP", "PEND", or "SIDEWALL" and "TOP". RECESSED SPRINKLER: A spray sprinkler assembly intended for installation with a concealed piping system. The assembly con- sists of a sprinkler installed in a decorative adjustable recessed escutcheon that minimizes the protrusion of the sprinkler beyond the ceiling or wall without adversely affecting the sprinkler distribution or sensitivity. Refer to the appropriate technical data page for allowable sprinkler models, temperature ratings, and occupancy classifications. DO NOT RECESS ANY SPRINKLER NOT LISTED FOR USE WITH THE ESCUTCHEON. CORROSION -RESISTANT SPRINKLER: A special service sprinkler with non -corrosive protective coatings, or that is fabricated from non -corrosive material, for use in atmospheres that would normally corrode sprinklers. DRY SPRINKLER: A special -service sprinkler intended for installation on dry pipe systems or wet pipe systems where the sprinkler is subject to freezing temperatures. The unit consists of a sprinkler permanently secured to an extension nipple with a sealed inlet end to prevent water from entering the nipple until the sprinkler operates. The unit MUST be installed in a tee fitting. Dry upright sprinklers are marked with the "B" dimension [distance from the face of the fitting (tee) to the top of the deflector]. Dry pendent and sidewall sprinklers are marked with the "A" dimension [the distance from the face of fitting (tee) to the finished surface of the ceiling or wall]. LARGE DROP SPRINKLER: A type of special application sprinkler used to provide fire control of specific high -challenge fire haz- ards. Large drop sprinklers are designed to produce an umbrella -shaped spray pattern downward with a higher percentage of "large" water droplets than standard spray sprinklers. The sprinkler has an extra -large orifice with a nominal K-Factor of 11.2. Marked "HIGH CHALLENGE" and "UPRIGHT'. EARLY SUPPRESSION FAST -RESPONSE (ESFR) SPRINKLER: A sprinkler intended to provide fire suppression of specific high - challenge fire hazards through the use of a fast response fusible link, 14.0, 16.8, or 25.2 nominal K-Factor, and special deflector. ESFR sprinklers are designed to produce high -momentum water droplets in a hemispherical pattern below the deflector. This permits penetration of the fire plume and direct wetting of the burning fuel surface while cooling the atmosphere early in the development of a high -challenge fire. Marked "ESFR" and "UPRIGHT' or "PEND". INTERMEDIATE LEVEL/RACK STORAGE SPRINKLER: A standard spray sprinkler assembly designed to protect its operating element from the spray of sprinklers installed at higher elevations. The assembly consists of a standard or large orifice upright or pendent sprinkler with an integral upright or pendent water shield and guard assembly. Use only those sprinklers that have been tested and listed for use with the assembly. Refer to the technical data page for allowable sprinkler models. RESIDENTIAL SPRINKLER: A sprinkler intended for use in the following occupancies: one- and two-family dwellings with the fire protection sprinkler system installed in accordance with NFPA 13D; residential occupancies up to four stories in height with the fire protection system installed in accordance with NFPA 13R; and where allowed by the Authority Having Jurisdiction in resi- dential portions of any occupancy with the fire protection system installed in accordance with NFPA 13. Form No. F_080814 18.12.06 Rev 14.1.P65 Page 3 of 3 N4 I Ki 7W74j] 111 i 9 SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Residential sprinklers have a unique distribution pattern and utilize a "fast response" heat sensitive operating element. They en- hance survivability in the room of fire origin and are designed to provide a life safety environment for a minimum of ten minutes. For this reason, residential sprinklers must not be used to replace standard sprinklers unless tested for and approved by the Authority Having Jurisdiction. In addition to standard markings, the unit is identified as "RESIDENTIAL SPRINKLER" or "RES". 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION Refer to the appropriate sprinkler technical data page(s). 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. IMPORTANT. Always referto Bulletin Form No. F_091699 - Care and Handling of Sprinklers and the appropriate sprin- klergeneral care, installation, and maintenance guide. Viking sprinklers areto be installed in accordancewiththe latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and alsowith the provisions of governmental codes, ordinances, and standards, wheneverapplicable. The sprinkler technical data page may contain installation requirements specific for the sprinkler model selected. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. Form No. F_080814 18.12.06 Rev 14.1.P65 Replaces Form No. F_080814 Rev 14.1 (Added P65 Warning.) Page 1 of 1 BEST PRACTICES FOR RESIDENTIAL SPRINKLER N4 I KJ 7W7*J]JJJJ HANDLING & INSTALLATION The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. SPRINKLERS ARE FRAGILE - HANDLE WITH CARE! • Always keep sprinklers in a cool dry place. • Protect sprinklers during storage, transport and handling as well as before, during and after installation. Refer to Viking's Care and Handling of Sprinklers Bulletin Form No. F_0916991. • Proper transit, storage and installation of sprinklers in a high -heat environment is a must. Care should be taken to prevent sprinklers from being exposed to ambient heat conditions in excess of those referenced in installation standards. • Do not stage or store sprinklers on the job site in advance in a non -conditioned space prior to installation. • Keep sprinklers in the original packaging and check temperature indicators on box label prior to installation. If the indicator has turned black, DO NOT install any product contained in the box. Refer to Viking product return policies. • Temperatures exceeding the maximum ambient temperature of the sprinkler temperature -rating during storage, transport, handling and installation must be avoided. • Per NFPA standards 13, 13R, and 13D, sprinklers installed where maximum ambient temperatures are at or over 101 °F (38 °C ) through 150 °F (66 °C) shall be intermediate temperature -rated sprinklers. Additionally, if sprinklers are installed in an unventilated concealed space under an uninsulated roof or in an unventilated attic, they shall be of intermediate temperature classification. • Sprinklers installed where ambient temperatures are at or below 100 °F (38 °C) may be either ordinary or intermediate temperature -rated sprinklers. Refer to NFPA standards 13R 6.2.3.1 and 13D 7.5.6.1. • Rough -in of sprinkler piping during hot weather conditions should not include the installation of sprinklers unless reasonable ambient temperatures can be maintained. Ambient temperatures that are considered when choosing the temperature rating for a sprinkler should take into account the range of ambient temperatures that are expected from installation through establishment and maintenance of temperature in a conditioned space. Appropriate insulation may be considered. Example: An ordinary temperature sprinkler should not be exposed to maximum ambient temperature higher than 100 °F (38 °C) or more. Refer to NFPA 13, Table 6.2.5.1, NFPA 13R, 6.2.3.1 and NFPA 13D, 7.5.6.1. • CPVC fire sprinkler products exposed to high ambient temperatures (e.g. installed in unventilated, concealed spaces such as attics) should be insulated to maintain a cooler environment. Refer to Viking Plastics Installation and Design Manual, Form No. F_0807122, for care and handling procedures. • Protect all sprinklers and connecting CPVC piping in attic spaces and unvented concealed spaces from excessive heat exposure above 100 °F (38 °C). To separate excessive attic heat, properly tent and fully insulate all pipe in unconditioned spaces. • Pressure relief valves should be installed on wet sprinkler systems where there is a risk of over -pressurization of a checked water supply, due to thermal expansion. Refer to NFPA 13, 7.1.2.1 and NFPA 13D, A.5.2.2.2. • Fire sprinkler systems should be installed per current referenced editions of building codes and installation standards adopted in the jurisdiction where work is being performed. WARNING: Cancer and Reproductive Harm- Zt 'Hot weather condition is defined as temperatures that can reach the maximum ambient temperature -rating of the sprinkler. 'Clicking on blue hyperlink will open referenced document. TORE INDICATOR DO NOT ACCEP IPMENT ABOVE INDIC DOT IS BLACK O O INCORRECT (Heat exposure) INCORRECT (Unconditioned at rough -in) INCORRECT (Exposed piping) INCORRECT (No pressure relief valve) Any sprinkler with a loss of liquid from the glass bulb or damage to the fusible element should be destroyed. Never install sprinklers that have been dropped, damaged, or exposed to temperatures exceeding the maximum ambient temperature allowed. Sprinklers that have been painted in the field must be replaced per NFPA 13. Protect sprinklers from paint and paint overspray in accordance with the installation standards. Do not clean sprinklers with soap and water, ammonia, or any other cleaning fluid. Do not use adhesives or solvents on sprinklers or their operating elements. Refer to the appropriate technical data page and NFPA standards for complete care, handling, installation, and maintenance instructions. For additional product and system information Viking data pages and installation instructions are available on the Viking Web site at WWw. vikinggroupinc.com. Form No. F_080415 18.10.11 Rev 16.3.P65 Page 1 of 1 N4 I KJ REGULATORYAND HEALTH WARNINGS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Regulatory and Health Warnings applying to materials used in the manufacture and construction of fire protection products are provided herin as they relate to legally mandated jurisdictional regions. A WARNING STATE OF CALIFORNIA, USA Installing or servicing fire protection products such as sprinklers, valves, piping etc. can expose you to chemicals including, but not li- mited to, lead, nickel, butadiene, titaninum dioxide, chromium, carbon black, and acrylonitrile which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov 2. WARRANTY TERMS AND CONDITIONS For details of warranty, refer to Viking's current list price schedule at www.vikinggroupinc.com or contact Viking directly. Form No. F 111218 18.11.15 Rev 18.1 New Bulletin