REVIEWED BLD BLD2021-1482+WSEC+10.28.2021_9.47.55_AM+2488217BLD2021-1482 RECEIVED Nov 15 2021 Window, Skylight and Door Schedule Project Information Contact Information Chris and Lisa Burdett Blake Fisher, AIA 332 Sunset Ave. N blake blakefisherarchitecture.com Edmonds, WA 98020 206-852-5054 Ref. U-factor Exempt Swinging Door (24 sq. ft. max.) Exempt Glazed Fenestration (15 sq. ft. max.) Vertical Fenestration (Windows and doors) Component Description Ref. U-factor Western Windows Series 600 WindowWall A 0.30 Western Windows Series 600 WindowWall B 0.30 Western Windows Series 600 WindowWall C 0.30 Western Windows Series 600 WindowWall D 0.30 NOT USED E Mil and Ultra Series C650 PICT. series 3310 F 0.27 Mil and Ultra Series C650 PICT. series 3310 G 10.27 l and Ultra Series C650 SLIDER series 3110 H 0.27 l and Ultra Series C650 SLIDER series 3110 J 0.27 l and Ultra Series C650 SLIDER series 3110 K 0.27 Mil and Ultra Series C650 CASEMENT L 0.27 Mil and Ultra Series C650 CASEMENT M 0.27 Mil and Ultra Series C650 PICT. series 3310 N 0.27 Mil and Ultra Series C650 PICT. series 3310 P 10.27 l and Ultra Series C650 SLIDER series 3110 Q 0.27 l and Ultra Series C650 SLIDER series 3110 R 0.27 Mil and Ultra Series C650 PICT. series 3310 S 0.27 Mil and Ultra Series C650 PICT. series 3310 T 0.27 Mil and Ultra Series C650 PICT. series 3310 U 0.27 l and Ultra Series C650 SLIDER series 3110 V 0.27 Mil and Ultra Series C650 PICT. series 3310 W 10.27 l and Ultra Series C650 SLIDER series 3110 X 0.27 Mil and Ultra Series C650 PICT. series 3310 Y 0.27 Mil and Ultra Series C650 PICT. series 3310 Z 0.27 Mil and Ultra Series C650 PICT. series 3310 AA 0.27 Mil and Ultra Series C650 PICT. series 3310 BB 0.27 l and Ultra Series C650 SLIDER series 3110 CC 0.27 Western Windows Series 600 MultiSlide Dr. 1 0.33 NOT USED 2 0.33 Western Windows Series 600 MultiSlide Dr. 3 0.33 Custom Solid Core Pivot Entry Door 4 0.33 Western Windows Series 600 MultiSlide Dr. 5 0.33 e Door - Northwest Door Modern Class Line or 6 0.28 e Door - Northwest Door Modern Class Line or 7 0.28 Renlita Nufold Bi-fold door 8 0.28 Solid Core Entry Door 9 0.33 Glazed Patio Door 10 0.28 int. doors marked on door schedule Width Height Qt. Feet In" Feet I"°h Area UA 0.0 0.00 0.0 0.00 Width Height Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area 12079.61 602.75 0.29 Overhead Glazing (Skylights) Component Width Height Description Ref. U-factor Qt. Feet In" Feet 1-1, Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 1 0.01 0.00 Overhead Glazing Area Weighted U = UA/Area 0.00 Total Sum of Fenestration Area and UA (for heating system sizing calculations) 2079.E 602.75 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT :UNI UNTA0•J BY CITY OF EDMONDS simple I-leating system size: wasningion state This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information Chris and Lisa Burdett Blake Fisher, AIA 332 Sunset Ave. N blake@blakefisherarchitecture.com Edmonds, WA 98020 206.852.5054 AM Heating System Type: O All Other systems Ce Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds A AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 6,223 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 10.01 62,230 Glazing and Doors U-Factor X Area = UA Instructions u-o.zB . 0.280 2,079 582.12 Skylights U-Factor X Area = UA Instructions 0.50 F—E-1 --- Insulation Attic U-Factor X Area = UA Instructions Select R-Value No Selection F_ 0 1 --- Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions R-38 Vented W 0.027 3,485 94.10 Above Grade Walls (see Figure i) U-Factor X Area UA Instructions R-21 Intermediate 0.056 5,409 302.90 Floors U-Factor X Area UA Instructions �1 0.029 574 16.65 Below Grade Walls (see Figure i) U-Factor X Area UA Instructions R-21 Interior ri 0.042 Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions in No Slab Below Grade � 0.303 � --- this project. Slab on Grade (see Figure 1) F-Factor X Length UA Instructions R-10 Fully Insulated 0.360 3,695 1330.20 Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space 1.00 Sum of UA 2325.97 Figure 1. Above Grade 46 Envelope Heat Load 106,994 Btu / Hour Sum of UA x AT Air Leakage Heat Load 30,916 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 137,910 Btu/Hour Air leakage + envelope heat loss Building and Duct Heat Load 137,910 Btu/Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 172,388 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat DumD (07101113)