Loading...
SI report for concrete slab pourOTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing CONCRETE REPORT Job Number: 22-0366 Report Number: RC416072 Permit Number: BLD2021-1482 Project: Sunset Ave N Residence Client: American West Coast Construction Address: 332 Sunset Ave N, Edmonds Date: 02/17/2023 Inspector(s): Jonathan Andrews Description/Location: Slab on metal deck, 2nd floor West building, interior, per S3.2; and supplemental reinforcing steel plan with all additional (optional) reinforcing steel installed. Inspected to approved plans, approved mix design, and project documents. Rebar Verified: Yes 2/17/2023 Jonathan Andrews (Grade 60) Mfg: Cascade, Nucor Placement Data Design ❑d Actual ❑ Batch Weights/Cubic Yard Supplier: Miles Cement (Ibs/type): 517# Type: I-L Mix Number: 07450GF Fine Agg. (Ibs): 1570# Slump Spec: 7" max Coarse Agg. (Ibs/size): 1610# 3/8" Slag (Ibs): W/C Ratio Spec: 0.44 Coarse Agg. (Ibs/size): Air Spec: NA Coarse Agg. (Ibs/size): Total Yards: 34 Fly Ash (Ibs): Placed Via: Pump Water (Ibs or gal): 270# Consolidated: Yes Admixtures (specify): 1.0 oz per cwt. MSETAC534, 1.35 oz per cwt. GLENIUM 7500, 128 Required Strength: 4000 psi @ 28 days oz. MASTER LIFE Sampling and Testing Data Time Cubic Water Slump Air % Conc.Temp Ambient Truck Ticket ASTM C 172, C 31 Made Yards Added C 143 C 231 C 1064 Temp No. No. Cast Samples: 1-4 8:30 am 10.50 15 gal. 6.25" NA% 59°F 40°F 1160 1010051 Weather: Light Rain Slump Range: 6.25" Air % Range: NA Date Samples Picked Up: 2/20/2023 Initial Curing Method: ASTM C31, Exclude C31-12.1.5 Initial Curing Tmp: ASTM C31, Exclude C31-10.1.2 Comments Admixture: 1 bag - Fiberforce 150/1-oad. Placed per ACI criteria. REINFORCING/PLACEMENT: Conforms: ❑� Does Not Conform: ❑ COMPRESSIVE TEST RESULTS Fracture Type Specimen Test Field Age Size Daily Average Weight Max Load Strength (other Number Date Cure (Days) (in.) Area (Sq.ln.) Diam. (In.) (Lbs.) (Lbs.) (psi) than cone) 1 02/24/2023 7 4 x 8 12.62 4.01 8.5 45,520 3610 5 = Discarded Tested in general accordance to: ASTMC39 W ASTMC617 ❑ ASTMC1231 ❑ Copies to: �/ v�, Date: 2023.02.28 ❑./ Client ❑d Engineer El Others f��G El Owner ❑d Contractor Technical Responsibility: 08:13:50 -08�00� ❑ Architect 0 Building Dept Isaac Ruoff, Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report except in full, without written permission from our firm is strictly prohibited. 6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 725-4600 — Fax (206) 723-2221 Form No.: ADMIN-62-04 (Rev 09/06) Page 1 of 1