APPROVED RESUB1 BLD2023-1107+Architectural_Plan+10.2.2023_8.22.34_PM+3817206ABBREVIATIONS & AND AB ANCHOR BOLT ABV ABOVE A/C AIR CONDITIONING AD AREA DRAIN ADD'L ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISED FLOOR AHU AIR HANDLING UNIT ALUM ALUMINUM AP ACCESS PANEL ARCH ARCHITECTURAL BD BOARD BLDG BUILDING BLKG BLOCKING BLW BELOW B.O. BOTTOM OF CAB CABINET CJ CONTROL JOINT CL CENTER LINE CLG CEILING CLO CLOSET CUR CLEAR CMU CONCRETE MASONRY UNIT CU CONDENSING UNIT CO CARBON MONOXIDE DETECTOR COL COLUMN CONC CONCRETE CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CTR CENTER D DEEP DBL DOUBLE DIA DIAMETER DIM DIMENSION DN DOWN DR DOOR IDS DOWN SPOUT DTL DETAIL DW DISHWASHER DWG DRAWING DWR DRAWER EA EACH EF EXHAUSTFAN EL ELEVATION ELEC ELECTRIC/ELECTRICAL ELEV ELEVATOR EP ELECTRIC PANEL EQ EQUAL EW EACH WAY EXP EXPANSION EXST/EX EXISTING EXT EXTERIOR F.F. FINISHED FLOOR FIN FINISH FLR FLOOR FND FOUNDATION F.O. FACE OF FT FEET FTG FOOTING FURR FURRING G GAS GA GAUGE GALV GALVANIZED GND GROUND GPM GALLONS PER MINUTE GR GRADE GWB GYPSUM WALL BOARD H HIGH HB HOSE BIBB HD HEAD HDW HARDWARE HDWD HARDWOOD HT HEIGHT HVAC HEATING, VENTILATION, AIR CONDITIONING HWH HOT WATER HEATER IRC INTERNATIONAL RESIDENTIAL CODE IN INCHES ID INSIDE DIAMETER INCL INCLUDED/INCLUDING INSUL INSULATION INT INTERIOR J JACK JT JOINT L LENGTH LBS POUNDS MAS MASONRY MATL MATERIAL MAX MAXIMUM MDF MEDIUM DENSITY FIBERBOARD MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM M.O. MASONRY OPENING MTL METAL N NEW N/A NOT APPLICABLE NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE O.C. ON CENTER OD OUTSIDE DIAMETER OVHD OVERHEAD PNT/PTD PAINT / PAINTED PL PLATE PLUM PLUMBING PLYWD PLYWOOD PR PAIR PSD POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH P.T. PRESSURE TREATED R RISER RAID RADIUS REF REFRIGERATOR REINF REINFORCED REQ'D REQUIRED REV REVISION RM ROOM R.O. ROUGH OPENING S SOUTH SCHED SCHEDULE SD SMOKE DETECTOR SECT SECTION SF SQUARE FEET SHT SHEET SIM SIMILAR SLVG SALVAGE SPEC SPECIFICATION SQ SQUARE STD STANDARD STL STEEL STRUC STRUCTURE T TREAD TBD TO BE DETERMINED TEL TELEPHONE THK THICK THRESH THRESHOLD T.O. TOP OF TYP TYPICAL UNF UNFINISHED LINO UNLESS NOTED OTHERWISE UL UNDERWRITERS LABORATORIES VAN VANITY V.B. VAPOR BARRIER VTR VENT THROUGH ROOF W WIDE W. WITH WC WATER CLOSET WD WOOD W/D WASHER/DRYER WDW WINDOW W/O WITHOUT WP WATERPROOF DRAWING STANDARDS DIMENSION METHOD OVERALL DIMENSION - OUTSIDE FACE OF STUDS EXTERIOR WALL LOCATION OUTSIDE FACE OF STUDS WINDOW/DOOR CENTERLINES INTERIOR PARTITION LOCATIONS AND WALL THICKNESSES TO EACH FACE OF STUD 5 1/2" 5 1/2" 3 1/2" 5 1/2" ±7'-1V, 1 11 8'-8"TT APPROXIMATE DIMENSION T FIXED DIMENSION DRAWING SYMBOLS DOOR TAG WINDOW TAG ROOM TAG 101 DOOR NUMBER 1t f WINDOW TYPE PER SCHEDULE PER SCHEDULE Room name 36" 101 ROOM NUMBER PER SCHEDULE DOOR W IDTH 150 SF ROOM AREA KEYNOTE ALIGN FINISHED SURFACES SECTION MARK f KEYNOTE NUMBER, REFER FE- TO SCHEDULE ALIGN 1 DRAWING NUMBER �� A101 SHEET NUMBER STORY ELEVATION Name Elevation 3D VIEW OF THE PROJECT COMMON MATERIALS u arc. c CONCRETE EARTH GRAVEL RIGID INSULATION LOOSE FILL LOOSE FILL BATT INSULATION BOARD INSULATION INSULATION PLYWOOD WOOD METAL ROOF ASPHALT WOOD FLOORING LOOSE FILL SHINGLES INSULATION SCOPE OF WORK INTERIOR REMODEL OF EXISTING HOME IN EDMONDS. NO EXTERIOR WORK, ALL WORK WILL BE INSIDE EXISTING WALLS. NEW ROOF IS RECENT. STRUCTURAL WORK INSIDE CONSISTS OF REMOVING EXITING WALLS, AND RETROFITTING EXISTING STRUCTURE TO SUPPORT AN OPEN FLOOR PLAN. STRUCTURAL DRAWINGS PROVIDED. CODES I CODES 2018 INTERNATIONAL BUILDING CODE CONSTRUCTION TYPE: 5B (EXISTING) 2018 INTERNATIONAL MECHANICAL CODE 2018 UNIFORM PLUMBING CODE 5B (PROPOSED) 2018 INTERNATIONAL MECHANICAL CODE SPRINKLERS: NONE EXISTING. NONE TO BE ADDED 2018 INTERNATIONAL FIRE CODE WITH NEW CONSTRUCTION. 2018 WASHINGTON STATE ENERGY CODE CODE ANALYSIS GENERAL NOTES: 1. ALL NOTES UNDER THIS CONTRACT SHALL COMPLY WITH THE CURRENT EDITIONS OF THE IRC 2018, WASHINGTON STATE ENERGY CODE 2018, IMC 2018, WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE, UNIFORM PLUMBING CODE, NATIONAL ELECTRIC CODE, AND WASHINGTON STATE DEPARTMENT OF LABOR AND INDUSTRIES REGULATIONS 2. GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL EXISTING AND NEW UTILITIES AND SITE CONDITIONS BEFORE AND DURING CONSTRUCTION, INFORM ARCHITECT OF VARIATIONS BETWEEN CONTRACT DOCUMENTS AND EXISTING CONDITIONS. 3. DO NOT SCALE DRAWINGS, VERIFY ALL DIMENSIONS ON THE JOB 4. DIMENSIONS ARE TO FACE OF FOUNDATION WALLS AND FACE OF ROUGH FRAMING UNLESS OTHERWISE NOTED. FOR DIMENSIONS TO EXISTING STRUCTURE ASSUME FACE OF (E) FINISHED SURFACE 1-------------------------------1 5. FLOOR -TO -FLOOR DIMENSIONS FROM TOP OF SUBFLOOR TO TOP PLATES, UNLESS NOTED OTHERWISE ; A separate plumbing permit is ; ALL WORK SUBJECT 6. PROVIDE SOLID BLOCKING BEHIND ALL WALL HUNG FIXTURES AND ACCESSORIES. required for this permit. TO FIELD CODE NOTES: 1. OPENINGS SHALL BE CAULKED, OR WEATHER STRIPPED 1 1 INSPECTION FOR 2. SEAL TEARS AND JOINTS IN INSULATION WITH TAPE. 3. MOISTURE CONTROL To BE PROVIDED PER WA STATE ENERGY CODE Please obtain a plumbing permit CODE COMPLIANCE 4. HOT WATER HEATERS SHALL COMPLY WITH THE NATIONAL APPLIANCES CONSERVATION ACT 1 1 from the Edmonds. 5. SERVICES WATER PIPES IN UNHEATED SPACES SHALL BE INSULATED PER WA STAR ENERGY CODE city of 6. ALL NAILING PER IRC 1__---------------------------__1 7. PROVIDE SMOKE DETECTORS PER IRC- IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA, CONTRACTOR TO VERIFY SD'S ARE PROPERLY INSTALLED IN EXITING HOME 8. SMOKE DETECTORS SHALL BE POWERED BY THE BUILDING WIRING WITH A BATTERY BACKUP. 9. CARBON MONOXIDE ALARMS TO BE INSTALLED PER IRC- OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS. CONTRACTOR TO VERIFY 10. PROVIDE FIRE BLOCKING, DRAFTSTOPS, AND FIRESTOPS PER THE IRC 11. PROVIDE APPROVED SECURITY AND LOCKING DEVICES AT NEW DOORS AND WINDOWS PER IRC. CODE SUMMARY: R314: Smoke alarms are to be installed in each sleeping room, outside each separate sleeping area in the immediate vicinity of the bedrooms, on each additional story of the dwelling, including basements and habitable attics. Alarms shall receive their primary power from the building wiring with battery back-up. Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection. Smoke alarms shall be interconnected and comply with household fire warning equipment provisions of NFPA 72.Low volt NFPA 29 in chapter 29 may be substituted pending approval by fire Mashal. R315: Carbon monoxide alarms are required on each floor and outside of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units within which fuel -fired appliances are installed and in dwelling units that have attached garages. R602.5 Interior Nonbearing Walls Interior nonbearing walls shall be permitted to be constructed with 2-inch by 3-inch (51 mm by 76 mm) studs spaced 24 inches (610 mm) on center or, where not part of a braced wall line, 2-inch by 4-inch (51 mm by 102 mm) flat studs spaced at 16 inches (406 mm) on center. Interior nonbearing walls shall be capped with not less than a single top plate. Interior nonbearing walls shall be fireblocked in accordance with Section R602.8. IRC M1503.6 Makeup Air Required Where one or more gas, liquid or solid fuel -burning appliance that is neither direct -vent nor uses a mechanical draft venting system is located within a dwelling unit's air barrier, each exhaust system capable of exhausting in excess of 400 cubic feet per minute (0.19 m3/s) shall be mechanically or passively provided with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with not fewer than one damper complying with Section M1503.6.2. M1503.6.1 Location Kitchen exhaust makeup air shall be discharged into the same room in which the exhaust system is located or into rooms or duct systems that communicate through one or more permanent openings with the room in which such exhaust system is located. Such permanent openings shall have a net cross -sectional area not less than the required area of the makeup air supply openings. M1503.6.2 Makeup P Air Dampers Where makeupair is required b Section M1503.6 makeup air dampers shall comply with this section. Each damper shall be a gravity damper or an electrically operated damper that automatically opens when the exhausts stem operates. Dampers q Y � p P pY P 9 Y p Y p P Y p Y P P shall be located to allow access for inspection, service, repair and replacement without removing permanent construction or any other ducts not connected to the damper being inspected, serviced, repaired or replaced. Gravity or barometric dampers shall not be used in passive makeup air systems except where the dampers are rated to provide the design makeup airflow at a pressure differential of 0.01 in. w.c. (3 Pa) or less. M1505.4.1.2 Exhaust Fans Exhaust fans required shall be ducted directly to the outside. Exhaust air outlets shall be designed to limit the pressure difference to the outside and equipped with backdraft dampers or motorized dampers in accordance with the Washington State Energy Code. Exhaust fans shall be tested and rated in accordance with the airflow and sound rating procedures of the Home Ventilating Institute (HVI 915, HVI Loudness Testing and Rating Procedure, HVI 916, HVI Airflow Test Procedure, and HVI 920, HVI Product Performance Certification Procedure, as applicable). Exhaust fans required in this section may be used to provide local ventilation. Bathroom exhaust fans that are designed for intermittent exhaust airflow rates higher than the continuous exhaust airflow rates in Table M1505.4.3(3) shall be provided with occupancy sensors or humidity sensors to automatically override the fan to the high speed airflow rate. The exhaust fans shall be tested and the testing results shall be submitted and posted in accordance with Section M1505.4.1.6. M1505.4.4 Local Exhaust Rates Local exhaust systems shall be designed to have the capacity to exhaust the minimum airflow rate determined in accordance with Table M1505.4.4(1). If the local exhaust fan is included in the whole -house ventilation system, in accordance with Section 1505.4.1, then the exhaust fan shall be controlled to operate as specified in Section M1505.4.2. M1403.1 Heat Pumps Electric heat pumps shall be listed and labeled in accordance with UL 1995 or UL/CSA/ANCE 60335-2-40. M1405.1 General Electric baseboard convectors shall be installed in accordance with the manufacturer's instructions and Chapters 34 through 43. Electric baseboard heaters shall be listed and labeled in accordance with UL 1042. M1505.4 Whole -House Mechanical Ventilation System Each dwelling unit shall be equipped with a ventilation system. The whole -house mechanical ventilation systems shall be designed in accordance with Sections M1505.4.1 through M1505.4.4. M1505.4.1 System Design The whole -house ventilation system shall consist of one or more supply fans, one or more exhaust fans, or an ERV/HRV with integral fans, associated ducts and controls. Whole -house mechanical ventilation system with supply and exhaust fans per Sections M1505.4.1.2, M1505.4.1.3, M1505.4.1.4, and M1505.4.1.5. Local exhaust fans are permitted to serve as part of the whole -house ventilation system when provided with the proper controls per Section M1505.4.2. The systems shall be designed and installed to exhaust and/or supply the minimum outdoor airflow rates per Section M1505.4.3 as modified by the whole -house ventilation system coefficients in Section M1504.5.3.1 where applicable. The whole -house ventilation system shall operate continuously at the minimum ventilation rate determined per Section M1505.4.2 unless configured with intermittent off controls per Section M1505.4.3.2. ENERGY NOTES: WSEC 2018 INSULATION & FENESTRATION RQMTS BY COMPONENT- CLIMAX ZONE 4C- TABLE R402.1.1 FENESTRATION U FACTOR CEILING R-VALUE WOOD FRAMED WALL R VALUE FLOOR R-VALUE .28 R-49 FLAT CEILING R-21+ R-4 R-38 1. ALL EXISTING WALL, FLOOR, AND CEILING AND ROOF AREAS OPENED UP DURING CONSTRUCTION ACTIVITIES WILL BE INSULATED PER THE CAPACITY OF THE WALL/ROOF CAVITY OR PER CODE- WHICHEVER IS LESS- INTENT IS TO IMPROVE INSULATION VALUES AS MUCH AS POSSIBLE WITHIN THE EXISTING FRAMEWORK BRINING THE HOUSE UP TO CURRENT CODE REQUIREMENTS (2X6=R-21 BATT INSULATION, 2X4 = R-15 BATT INSULATION PER R101.4.3 EXCEPTION. 2. ALL NEW HEADERS IN EXTERIOR WALLS SHALL BE INSULATED TO R-10 (RIGID INSULATION BETWEEN 202X8'S- 4X8 EQIVALENT) 3. ALTERATIONS (REMODELS) DO NOT NEED TO OBTAIN ENERGY CREDITS FROM TABLE R406.3 1. EXPOSED WALL CAVITIES MUST BE INSULATED, 2X4 REQUIRES R-15 INSULATION, 2X6 REQUIRES R-21 2. EXPOSED TOOF AND CEILING ASSEMBLIES MUST BE INSULATED 3. EXPOSED FLOOR CAVITIES MUST BE INSULATED TO R-30 4. NEW EQUIPMENT MUST MEET CURRENT REQUIREMETNS AND DUCTS NEED TO BE TESTED 5. 90 % OF ALL LAMPS MUST BE HIGH EFFICACY 4. R503.1.1 BUILDING ENVELOPE. BUILDING ENVELOPE ASSEMBLIES THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R402.1.1 OR R402.1.4, SECTIONS R402.2.1 THROUGH R402.2.11 5. R503.1.1.1 REPLACEMENT FENESTRATION. WHERE SOME OR ALL OF AN EXISTING FENESTRATION UNIT IS REPLACED WITH A NEW FENESTRATION PRODUCT, INCLUDING SASH AND GLAZING, THE REPLACEMENT FENESTRATION UNIT SHALL MEET THE APPLICABLE REQUIREMENTS FOR U-FACTOR AND SHGC IN TABLE R402.1.1. WHERE MORE THAN ONE REPLACEMENT FENESTRATION UNIT IS BEING INSTALLED, AN AREA -WEIGHTED AVERAGE OF THE U-FACTOR AND SHGC OF ALL REPLACEMENT FENESTRATION SHALL BE PERMITTED TO BE USED TO DEMONSTRATE COMPLIANCE. 6. R503.1.2 HEATING AND COOLING SYSTEMS. NEW HEATING, COOLING AND DUCT SYSTEMS THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R403. EXCEPTIONS: 1. WHERE DUCTS FROM AN EXISTING HEATING AND COOLING SYSTEM ARE EXTENDED, DUCT SYSTEMS WITH LESS THAN 40 LINEAR FEET IN UNCONDITIONED SPACES SHALL NOT BE REQUIRED TO BE TESTED IN ACCORDANCE WITH SECTION R403.2.2. 2. EXISTING DUCT SYSTEMS CONSTRUCTED, INSULATED OR SEALED WITH ASBESTOS. 7. R503.1.4 LIGHTING. NEW LIGHTING SYSTEMS THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R404.1. 8. R503.2 CHANGE IN SPACE CONDITIONING. ANY NONCONDITIONED OR LOW -ENERGY SPACE THAT IS ALTERED TO BECOME CONDITIONED SPACE SHALL BE REQUIRED TO BE BROUGHT INTO FULL COMPLIANCE WITH THIS CODE. PROJECT LOCATION ADDRESS: 717 DALEY STREET EDMONDS, WAp^- - L fr-• PARCEL: 00434208303400 Q LEGAL: SW1/4 SEC24 T27N R3E y: N SITE DRAWING INDEX Sheet No. Sheet Name Revision Date A001 SITE PLAN A100 FLOOR PLAN A101 RENDERINGS A102 CEILING PLAN The following documentation shall be available on site for the building inspector: ! ■ ■ ■ ■ x❑ COE APPROVED ARCHITECTURAL PLAN SET ! X] COE APPROVED STRUCTURAL PLAN SET ■ ■ ❑x COE REVIEWED CALCULATION PACKET ; ❑ ENERGY CREDIT WORKSHEET ❑ SITE PLAN ■ ; CIVIL PLAN ■ ■ El ; 2 ❑ ■ ■ ; ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■-------------------------------------- City Of Edmonds Building Department Work INTERIOR REMODEL ------------------------------------ Address 717 DALEY Owner MEYERS Approved Dater 10/16/2023 Building Official � -------------- ---------------------- Permit Number; BLD2023-1107 DATE REVISIONS PAGES - CHANGES REV1 REV2 REV3 REV4 REV5 PROJECT TEAM OWNER NAMES ADDRESS OWNER DRIFT INTERIOR ARCHITECTURE 14526 107TH ST NE ARCHITECT LAKE STEVENS, WA (E): JEN@DRIFT-IA.COM (P): 425-478-0327 CONTACT: JEN TAMBLIN BUILDER BUILDER ADDRESS BUILDER NAME STRUCTURAL ENGINEER ENGINEER ADDRESS ENGINEER ADDRESS OTHER CONSULTANT OTHER ADDRESS OTHER CONSULTANT 103 91st Ave SE, Lake 4254780327 Stevens. WA 98258 www.drift-ia.com Registered Architect in WA State W J Q REVISION LOG REV # DATE STATUS DPS PERMIT NUMBER: BNA Project number: DRAWN BY: SHEET NAME SHEET NO. w z ° a 0 0 � J J J m m m RESUB Oct 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT w m m w w w Z U w z w U z a Q DESCRIPTION COVER SHEET G001 PERMIT Scale As indicated i 0 N M O in N O c c Q J Q Z W 0 V1 W O U .o 0_ E O U n3 c: a) 0 N c O c E n3 U cl�66 J ~ LL d ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS W Q 1 HOLY ROSARY SCHOOL �CL I II I 0 I \ / o I I o I/ DALEY01MCC 1 103 91st Ave SE, Lake 4254780327 Stevens. WA 98258 www.drift-ia.com I ° I / I ° I Registered Architect in WA State W J Q r U) U U) w HLu z O of of w w w 0 0 0 D D m m Co w U) Lu w w w a� Z U / W Z U w \ \ z a / O I / / \ REVISION LOG I I / REV # DATE DESCRIPTION STATUS DPS PERMIT NUMBER: BNA Project number: DRAWN BY: SHEET NAME SITE PLAN SHEET NO A001 1:18111 Author Scale 191 = 201-011 ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS W FIRST FLOOR NEW 1 /4" = 1'-0" WIC k MASTEF t BATH F7 LJ rl�� Es RY TH 2 FIRST FLOOR DEMO 1 /4" = 1'-0" kL FLOOR PLAN GENERAL NOTES 1. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED. 2. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF 1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE 2x6 STUDS AT PLUMBING WALLS. 3. 50 CFM EXHAUST FAN AT ALL NEW BATHROOMS 4. CONTRACTOR WILL APPLY FOR PLUMBING, MECHANICAL, ELECTRICAL PERMITS SEPARATLY. 6. DOOR JAMBS SHALL BE 3 1/2" TYPICAL UNLESS OTHERWISE NOTES 7. CONTRACTOR TO VERIFY TO INSPECTOR PRIOR TO FINAL DEMO INSPECTION, LOCATION, AND CONFIRMATION OF NON-STRUCTURAL DEMOED WALLS. 8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WITH BATTERY BACK-UP. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE INTERCONNECTED AND COMPLY WITH HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72. CONTRACTOR TO PULL FIRE ALARM PERMIT FOR APPROPRIATE FIRE ALARM SYSTEM INSTALLER. 9. KITCHEN EXHAUST FAN TO BE A MINIMUM OF 100 CFM 10. BATHROOM EXHAUST FAN TO BE A MINIMUM OF 50 CFM 11. ALL OUTLETS SHOWN ARE CONVENIENCE OUTLETS, CODE COMPLIANT OUTLETS TO BE INSTALLED PER ELECTRIAL CODE - NEW CONSTRUCTION EXISTING TO REMAIN FLOOR PLAN KEYNOTES 103 91st Ave SE, Lake 1 4254780327 Stevens. WA 98258 www.drift-ia.com Registered Architect in WA State W r U) U U) Q W Lu z O D D w w w 0 0 0 m m Co U) w U) Lu w w w o a� a Z U W -7 W Z of U a Q REVISION LOG REV # DATE DESCRIPTION 1 1 Date 1 1 Revision 1 STATUS: PERMIT DPS PERMIT NUMBER: BNA Project number: XXXI)= DRAWN BY: Author SHEET NAME SHEET NO. FLOOR PLAN Scale 1 /4" = 1'-0" ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1 I 1 a Ii RENDERINGS NOT FINAL —.-Aft + •�y d .iy.r�h •�f.• S ,T �I 2 2 z ° m A v D m m D B `° m m v < G m z z Z ° A (n m W O D fD uu m c Z Z 3 T 717 n wm G) CD DALEY > N > W m� r- � 1 z 00 00� m h nO CLIENT NAME BUILDER NAME Z o ANN MEYERS o G) C) Cn lI BUILDER CONTACT V O PROJECT ADDRESS W l J O Z w D m XXX c 3 � BUILDER ADDRESS O .OT DATE: 10/2/2023 8:18:13 PM FILE C:\Users\jennifertamblin\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Ann Meyers\03 Revit\01 Work\D-IA-Ann Meyers-SD-RO-V23 OPTION PATH: 2. rvt FIRST FLOOR 1/4" = 1'-0" FLOOR PLAN GENERAL NOTES 1. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED. 2. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF 1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE 2x6 STUDS AT PLUMBING WALLS. 3. 50 CFM EXHAUST FAN AT ALL NEW BATHROOMS 4. CONTRACTOR WILL APPLY FOR PLUMBING, MECHANICAL, ELECTRICAL PERMITS SEPARATLY. 6. DOOR JAMBS SHALL BE 3 1/2" TYPICAL UNLESS OTHERWISE NOTES 7. CONTRACTOR TO VERIFY TO INSPECTOR PRIOR TO FINAL DEMO INSPECTION, LOCATION, AND CONFIRMATION OF NON-STRUCTURAL DEMOED WALLS. 8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WITH BATTERY BACK-UP. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE INTERCONNECTED AND COMPLY WITH HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72. CONTRACTOR TO PULL FIRE ALARM PERMIT FOR APPROPRIATE FIRE ALARM SYSTEM INSTALLER. 9. KITCHEN EXHAUST FAN TO BE A MINIMUM OF 100 CFM 10. BATHROOM EXHAUST FAN TO BE A MINIMUM OF 50 CFM 11. ALL OUTLETS SHOWN ARE CONVENIENCE OUTLETS, CODE COMPLIANT OUTLETS TO BE INSTALLED PER ELECTRIAL CODE - NEW CONSTRUCTION EXISTING TO REMAIN FLOOR PLAN KEYNOTES 103 91st Ave SE, Lake 1 4254780327 Stevens. WA 98258 www.drift-ia.com Registered Architect in WA State W r U) U U) Q W z O D D w w w 0 0 0 m m m U) w U) Lu w w w o a� a Z U W -7 W Z of U a Q REVISION LOG REV # DATE DESCRIPTION STATUS: PERMIT DPS PERMIT NUMBER: BNA Project number: XXXOM DRAWN BY: Author SHEET NAME SHEET NO. CEILING PLAN Scale Al 02 1 /4" = 1'-0" 1 ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS ELEVATION GENERAL NOTES ISLAND 2 1/2" = 1'-019 KITCHEN 1 KITCHEN 2 1 /2" = 1'-0" 1� (L 1� EQ EQ EQ EQ 0 OPEN SHELF 0 112' 1'-4114" 2'-8" 2'-8" �•-6" �•-6" ISLAND 1 /2" = 1'-0" CE li- PULL OUTS TRASH DKIFT INTERIOR ARCHITECTURE 103 91st Ave SE, Lake 4254780327 Stevens. WA 98258 www.drift-ia.com Registered Architect in WA State GM W r U) U U) Q W Lu z O Of Of w 0 0 0 J_ J_ J_ D D m m Co U) W U) Lu W ` r W W C) a� a Z U W -7 W Z a U Q REVISION LOG REV # DATE DESCRIPTION STATUS: PERMIT DPS PERMIT NUMBER: BNA Project number: XXXI) = DRAWN BY: Author SHEET NAME BUILDING ELEVATION SHEET NO. 1 /2" = 1'-0" ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS