APPROVED RESUB1 BLD2023-1107+Architectural_Plan+10.2.2023_8.22.34_PM+3817206ABBREVIATIONS
& AND
AB ANCHOR BOLT
ABV ABOVE
A/C AIR CONDITIONING
AD AREA DRAIN
ADD'L ADDITIONAL
ADJ ADJUSTABLE
AFF ABOVE FINISED FLOOR
AHU AIR HANDLING UNIT
ALUM ALUMINUM
AP ACCESS PANEL
ARCH ARCHITECTURAL
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLW BELOW
B.O. BOTTOM OF
CAB CABINET
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CUR CLEAR
CMU CONCRETE MASONRY UNIT
CU CONDENSING UNIT
CO CARBON MONOXIDE DETECTOR
COL COLUMN
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CTR CENTER
D DEEP
DBL DOUBLE
DIA DIAMETER
DIM DIMENSION
DN DOWN
DR DOOR
IDS DOWN SPOUT
DTL DETAIL
DW DISHWASHER
DWG DRAWING
DWR DRAWER
EA EACH
EF EXHAUSTFAN
EL ELEVATION
ELEC ELECTRIC/ELECTRICAL
ELEV ELEVATOR
EP ELECTRIC PANEL
EQ EQUAL
EW EACH WAY
EXP EXPANSION
EXST/EX EXISTING
EXT EXTERIOR
F.F. FINISHED FLOOR
FIN FINISH
FLR FLOOR
FND FOUNDATION
F.O. FACE OF
FT FEET
FTG FOOTING
FURR FURRING
G GAS
GA GAUGE
GALV GALVANIZED
GND GROUND
GPM GALLONS PER MINUTE
GR GRADE
GWB GYPSUM WALL BOARD
H HIGH
HB HOSE BIBB
HD HEAD
HDW HARDWARE
HDWD HARDWOOD
HT HEIGHT
HVAC HEATING, VENTILATION, AIR CONDITIONING
HWH HOT WATER HEATER
IRC INTERNATIONAL RESIDENTIAL CODE
IN INCHES
ID INSIDE DIAMETER
INCL INCLUDED/INCLUDING
INSUL INSULATION
INT INTERIOR
J JACK
JT JOINT
L LENGTH
LBS POUNDS
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
M.O. MASONRY OPENING
MTL METAL
N NEW
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O.C. ON CENTER
OD OUTSIDE DIAMETER
OVHD OVERHEAD
PNT/PTD PAINT / PAINTED
PL PLATE
PLUM PLUMBING
PLYWD PLYWOOD
PR PAIR
PSD POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
P.T. PRESSURE TREATED
R RISER
RAID RADIUS
REF REFRIGERATOR
REINF REINFORCED
REQ'D REQUIRED
REV REVISION
RM ROOM
R.O. ROUGH OPENING
S SOUTH
SCHED SCHEDULE
SD SMOKE DETECTOR
SECT SECTION
SF SQUARE FEET
SHT SHEET
SIM SIMILAR
SLVG SALVAGE
SPEC SPECIFICATION
SQ SQUARE
STD STANDARD
STL STEEL
STRUC STRUCTURE
T TREAD
TBD TO BE DETERMINED
TEL TELEPHONE
THK THICK
THRESH THRESHOLD
T.O. TOP OF
TYP TYPICAL
UNF UNFINISHED
LINO UNLESS NOTED OTHERWISE
UL UNDERWRITERS LABORATORIES
VAN VANITY
V.B. VAPOR BARRIER
VTR VENT THROUGH ROOF
W WIDE
W. WITH
WC WATER CLOSET
WD WOOD
W/D WASHER/DRYER
WDW WINDOW
W/O WITHOUT
WP WATERPROOF
DRAWING STANDARDS
DIMENSION METHOD
OVERALL DIMENSION - OUTSIDE FACE OF STUDS
EXTERIOR WALL LOCATION OUTSIDE
FACE OF STUDS
WINDOW/DOOR CENTERLINES
INTERIOR PARTITION LOCATIONS AND WALL THICKNESSES TO EACH FACE OF STUD
5 1/2" 5 1/2"
3 1/2" 5 1/2"
±7'-1V,
1
11 8'-8"TT
APPROXIMATE DIMENSION
T
FIXED DIMENSION
DRAWING SYMBOLS
DOOR TAG WINDOW TAG
ROOM TAG
101 DOOR NUMBER 1t f WINDOW TYPE
PER SCHEDULE PER SCHEDULE
Room name
36"
101 ROOM NUMBER
PER SCHEDULE
DOOR W IDTH
150 SF
ROOM AREA
KEYNOTE ALIGN FINISHED SURFACES
SECTION MARK
f KEYNOTE NUMBER, REFER
FE-
TO SCHEDULE
ALIGN
1 DRAWING NUMBER
��
A101 SHEET NUMBER
STORY ELEVATION
Name
Elevation
3D VIEW OF THE
PROJECT
COMMON MATERIALS
u arc. c
CONCRETE EARTH GRAVEL RIGID INSULATION
LOOSE FILL LOOSE FILL BATT
INSULATION
BOARD
INSULATION INSULATION
PLYWOOD WOOD METAL ROOF ASPHALT
WOOD FLOORING LOOSE FILL
SHINGLES
INSULATION
SCOPE OF WORK
INTERIOR REMODEL OF EXISTING HOME IN EDMONDS. NO EXTERIOR WORK, ALL WORK WILL BE INSIDE EXISTING WALLS. NEW ROOF IS RECENT.
STRUCTURAL WORK INSIDE CONSISTS OF REMOVING EXITING WALLS, AND RETROFITTING EXISTING STRUCTURE TO SUPPORT AN OPEN FLOOR PLAN.
STRUCTURAL DRAWINGS PROVIDED.
CODES I CODES
2018 INTERNATIONAL BUILDING CODE CONSTRUCTION TYPE: 5B (EXISTING)
2018 INTERNATIONAL MECHANICAL CODE
2018 UNIFORM PLUMBING CODE 5B (PROPOSED)
2018 INTERNATIONAL MECHANICAL CODE SPRINKLERS: NONE EXISTING. NONE TO BE ADDED
2018 INTERNATIONAL FIRE CODE WITH NEW CONSTRUCTION.
2018 WASHINGTON STATE ENERGY CODE
CODE ANALYSIS
GENERAL NOTES:
1. ALL NOTES UNDER THIS CONTRACT SHALL COMPLY WITH THE CURRENT EDITIONS OF THE IRC 2018,
WASHINGTON STATE ENERGY CODE 2018, IMC 2018, WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE,
UNIFORM PLUMBING CODE, NATIONAL ELECTRIC CODE, AND WASHINGTON STATE
DEPARTMENT OF LABOR AND INDUSTRIES REGULATIONS
2. GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL EXISTING AND NEW UTILITIES AND SITE CONDITIONS BEFORE
AND DURING CONSTRUCTION, INFORM ARCHITECT OF VARIATIONS BETWEEN CONTRACT DOCUMENTS AND EXISTING CONDITIONS.
3. DO NOT SCALE DRAWINGS, VERIFY ALL DIMENSIONS ON THE JOB
4. DIMENSIONS ARE TO FACE OF FOUNDATION WALLS AND FACE OF ROUGH FRAMING UNLESS OTHERWISE NOTED. FOR DIMENSIONS TO EXISTING STRUCTURE
ASSUME FACE OF (E) FINISHED SURFACE
1-------------------------------1
5. FLOOR -TO -FLOOR DIMENSIONS FROM TOP OF SUBFLOOR TO TOP PLATES, UNLESS NOTED OTHERWISE
; A separate plumbing permit is ;
ALL WORK SUBJECT
6. PROVIDE SOLID BLOCKING BEHIND ALL WALL HUNG FIXTURES AND ACCESSORIES.
required for this permit.
TO FIELD
CODE NOTES:
1. OPENINGS SHALL BE CAULKED, OR WEATHER STRIPPED
1 1
INSPECTION FOR
2. SEAL TEARS AND JOINTS IN INSULATION WITH TAPE.
3. MOISTURE CONTROL To BE PROVIDED PER WA STATE ENERGY CODE
Please obtain a plumbing permit
CODE COMPLIANCE
4. HOT WATER HEATERS SHALL COMPLY WITH THE NATIONAL APPLIANCES CONSERVATION ACT
1 1
from the Edmonds.
5. SERVICES WATER PIPES IN UNHEATED SPACES SHALL BE INSULATED PER WA STAR ENERGY CODE
city of
6. ALL NAILING PER IRC 1__---------------------------__1
7. PROVIDE SMOKE DETECTORS PER IRC- IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA, CONTRACTOR TO VERIFY SD'S ARE PROPERLY
INSTALLED IN EXITING HOME
8. SMOKE DETECTORS SHALL BE POWERED BY THE BUILDING WIRING WITH A BATTERY BACKUP.
9. CARBON MONOXIDE ALARMS TO BE INSTALLED PER IRC- OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS. CONTRACTOR
TO VERIFY
10. PROVIDE FIRE BLOCKING, DRAFTSTOPS, AND FIRESTOPS PER THE IRC
11. PROVIDE APPROVED SECURITY AND LOCKING DEVICES AT NEW DOORS AND WINDOWS PER IRC.
CODE SUMMARY:
R314:
Smoke alarms are to be installed in each sleeping room, outside each separate sleeping area in the immediate vicinity of the bedrooms, on each additional story of the dwelling, including basements and habitable attics. Alarms shall receive their primary power
from the building wiring with battery back-up. Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection. Smoke alarms shall be interconnected and comply with household fire warning equipment provisions of NFPA
72.Low volt NFPA 29 in chapter 29 may be substituted pending approval by fire Mashal.
R315:
Carbon monoxide alarms are required on each floor and outside of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units within which fuel -fired appliances are installed and in dwelling units that have attached garages.
R602.5 Interior Nonbearing Walls
Interior nonbearing walls shall be permitted to be constructed with 2-inch by 3-inch (51 mm by 76 mm) studs spaced 24 inches (610 mm) on center or, where not part of a braced wall line, 2-inch by 4-inch (51 mm by 102 mm) flat studs spaced at 16
inches (406 mm) on center. Interior nonbearing walls shall be capped with not less than a single top plate. Interior nonbearing walls shall be fireblocked in accordance with Section R602.8.
IRC M1503.6 Makeup Air Required
Where one or more gas, liquid or solid fuel -burning appliance that is neither direct -vent nor uses a mechanical draft venting system is located within a dwelling unit's air barrier, each exhaust system capable of exhausting in excess of 400 cubic feet per minute
(0.19 m3/s) shall be mechanically or passively provided with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with not fewer than one damper complying with Section M1503.6.2.
M1503.6.1 Location
Kitchen exhaust makeup air shall be discharged into the same room in which the exhaust system is located or into rooms or duct systems that communicate through one or more permanent openings with the room in which such exhaust system is located.
Such permanent openings shall have a net cross -sectional area not less than the required area of the makeup air supply openings.
M1503.6.2 Makeup P Air Dampers
Where makeupair is required b Section M1503.6 makeup air dampers shall comply with this section. Each damper shall be a gravity damper or an electrically operated damper that automatically opens when the exhausts stem operates. Dampers
q Y � p P pY P 9 Y p Y p P Y p Y P P
shall be located to allow access for inspection, service, repair and replacement without removing permanent construction or any other ducts not connected to the damper being inspected, serviced, repaired or replaced. Gravity or barometric dampers shall not be
used in passive makeup air systems except where the dampers are rated to provide the design makeup airflow at a pressure differential of 0.01 in. w.c. (3 Pa) or less.
M1505.4.1.2 Exhaust Fans
Exhaust fans required shall be ducted directly to the outside. Exhaust air outlets shall be designed to limit the pressure difference to the outside and equipped with backdraft dampers or motorized dampers in accordance with the Washington State Energy
Code. Exhaust fans shall be tested and rated in accordance with the airflow and sound rating procedures of the Home Ventilating Institute (HVI 915, HVI Loudness Testing and Rating Procedure, HVI 916, HVI Airflow Test Procedure, and HVI 920, HVI Product
Performance Certification Procedure, as applicable). Exhaust fans required in this section may be used to provide local ventilation. Bathroom exhaust fans that are designed for intermittent exhaust airflow rates higher than the continuous exhaust airflow rates in Table
M1505.4.3(3) shall be provided with occupancy sensors or humidity sensors to automatically override the fan to the high speed airflow rate. The exhaust fans shall be tested and the testing results shall be submitted and posted in accordance with Section M1505.4.1.6.
M1505.4.4 Local Exhaust Rates
Local exhaust systems shall be designed to have the capacity to exhaust the minimum airflow rate determined in accordance with Table M1505.4.4(1). If the local exhaust fan is included in the whole -house ventilation system, in accordance with Section
1505.4.1, then the exhaust fan shall be controlled to operate as specified in Section M1505.4.2.
M1403.1 Heat Pumps
Electric heat pumps shall be listed and labeled in accordance with UL 1995 or UL/CSA/ANCE 60335-2-40.
M1405.1 General
Electric baseboard convectors shall be installed in accordance with the manufacturer's instructions and Chapters 34 through 43. Electric baseboard heaters shall be listed and labeled in accordance with UL 1042.
M1505.4 Whole -House Mechanical Ventilation System
Each dwelling unit shall be equipped with a ventilation system. The whole -house mechanical ventilation systems shall be designed in accordance with Sections M1505.4.1 through M1505.4.4.
M1505.4.1 System Design
The whole -house ventilation system shall consist of one or more supply fans, one or more exhaust fans, or an ERV/HRV with integral fans, associated ducts and controls. Whole -house mechanical ventilation system with supply and exhaust fans per Sections
M1505.4.1.2, M1505.4.1.3, M1505.4.1.4, and M1505.4.1.5. Local exhaust fans are permitted to serve as part of the whole -house ventilation system when provided with the proper controls per Section M1505.4.2. The systems shall be designed and installed to exhaust
and/or supply the minimum outdoor airflow rates per Section M1505.4.3 as modified by the whole -house ventilation system coefficients in Section M1504.5.3.1 where applicable. The whole -house ventilation system shall operate continuously at the minimum ventilation rate
determined per Section M1505.4.2 unless configured with intermittent off controls per Section M1505.4.3.2.
ENERGY NOTES: WSEC 2018
INSULATION & FENESTRATION RQMTS BY COMPONENT- CLIMAX ZONE 4C- TABLE R402.1.1
FENESTRATION
U FACTOR
CEILING R-VALUE
WOOD FRAMED
WALL R VALUE
FLOOR
R-VALUE
.28
R-49 FLAT CEILING
R-21+ R-4
R-38
1. ALL EXISTING WALL, FLOOR, AND CEILING AND ROOF AREAS OPENED UP DURING CONSTRUCTION
ACTIVITIES WILL BE INSULATED PER THE CAPACITY OF THE WALL/ROOF CAVITY OR PER CODE- WHICHEVER IS LESS- INTENT IS TO IMPROVE INSULATION VALUES AS MUCH AS POSSIBLE WITHIN THE EXISTING FRAMEWORK BRINING THE HOUSE UP
TO CURRENT CODE REQUIREMENTS (2X6=R-21 BATT INSULATION, 2X4 = R-15 BATT INSULATION PER R101.4.3 EXCEPTION.
2. ALL NEW HEADERS IN EXTERIOR WALLS SHALL BE INSULATED TO R-10 (RIGID INSULATION BETWEEN 202X8'S- 4X8 EQIVALENT)
3. ALTERATIONS (REMODELS) DO NOT NEED TO OBTAIN ENERGY CREDITS FROM TABLE R406.3
1. EXPOSED WALL CAVITIES MUST BE INSULATED, 2X4 REQUIRES R-15 INSULATION, 2X6 REQUIRES R-21
2. EXPOSED TOOF AND CEILING ASSEMBLIES MUST BE INSULATED
3. EXPOSED FLOOR CAVITIES MUST BE INSULATED TO R-30
4. NEW EQUIPMENT MUST MEET CURRENT REQUIREMETNS AND DUCTS NEED TO BE TESTED
5. 90 % OF ALL LAMPS MUST BE HIGH EFFICACY
4. R503.1.1 BUILDING ENVELOPE. BUILDING ENVELOPE ASSEMBLIES THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R402.1.1 OR R402.1.4, SECTIONS R402.2.1 THROUGH R402.2.11
5. R503.1.1.1 REPLACEMENT FENESTRATION. WHERE SOME OR ALL OF AN EXISTING FENESTRATION UNIT IS REPLACED WITH A NEW FENESTRATION PRODUCT, INCLUDING SASH AND GLAZING, THE REPLACEMENT FENESTRATION UNIT SHALL MEET
THE APPLICABLE REQUIREMENTS FOR U-FACTOR AND SHGC IN TABLE R402.1.1. WHERE MORE THAN ONE REPLACEMENT FENESTRATION UNIT IS BEING INSTALLED, AN AREA -WEIGHTED AVERAGE OF THE U-FACTOR AND SHGC OF ALL
REPLACEMENT FENESTRATION SHALL BE PERMITTED TO BE USED TO DEMONSTRATE COMPLIANCE.
6. R503.1.2 HEATING AND COOLING SYSTEMS. NEW HEATING, COOLING AND DUCT SYSTEMS THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R403.
EXCEPTIONS:
1. WHERE DUCTS FROM AN EXISTING HEATING AND COOLING SYSTEM ARE EXTENDED, DUCT SYSTEMS WITH LESS THAN 40 LINEAR FEET IN UNCONDITIONED SPACES SHALL NOT BE REQUIRED TO BE TESTED IN ACCORDANCE WITH
SECTION R403.2.2.
2. EXISTING DUCT SYSTEMS CONSTRUCTED, INSULATED OR SEALED WITH ASBESTOS.
7. R503.1.4 LIGHTING. NEW LIGHTING SYSTEMS THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION R404.1.
8. R503.2 CHANGE IN SPACE CONDITIONING. ANY NONCONDITIONED OR LOW -ENERGY SPACE THAT IS ALTERED TO BECOME CONDITIONED SPACE SHALL BE REQUIRED TO BE BROUGHT INTO FULL COMPLIANCE WITH THIS CODE.
PROJECT LOCATION
ADDRESS: 717 DALEY STREET EDMONDS, WAp^-
- L fr-•
PARCEL: 00434208303400
Q
LEGAL: SW1/4 SEC24 T27N R3E
y:
N
SITE
DRAWING
INDEX
Sheet No.
Sheet Name
Revision
Date
A001
SITE PLAN
A100
FLOOR PLAN
A101
RENDERINGS
A102
CEILING PLAN
The following documentation shall be available on
site for the building inspector:
!
■
■
■
■
x❑ COE APPROVED ARCHITECTURAL PLAN SET
! X] COE APPROVED STRUCTURAL PLAN SET
■
■
❑x COE REVIEWED CALCULATION PACKET
; ❑ ENERGY CREDIT WORKSHEET
❑ SITE PLAN
■
;
CIVIL PLAN
■
■
El
;
2
❑
■
■
;
■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■--------------------------------------
City
Of
Edmonds
Building
Department
Work
INTERIOR REMODEL
------------------------------------
Address
717 DALEY
Owner
MEYERS
Approved Dater
10/16/2023
Building Official
�
--------------
----------------------
Permit Number;
BLD2023-1107
DATE
REVISIONS
PAGES - CHANGES
REV1
REV2
REV3
REV4
REV5
PROJECT
TEAM
OWNER NAMES
ADDRESS OWNER
DRIFT INTERIOR ARCHITECTURE
14526 107TH ST NE ARCHITECT
LAKE STEVENS, WA
(E): JEN@DRIFT-IA.COM
(P): 425-478-0327
CONTACT: JEN TAMBLIN
BUILDER
BUILDER ADDRESS BUILDER NAME
STRUCTURAL ENGINEER
ENGINEER ADDRESS ENGINEER ADDRESS
OTHER CONSULTANT
OTHER ADDRESS OTHER CONSULTANT
103 91st Ave SE, Lake 4254780327
Stevens. WA 98258
www.drift-ia.com
Registered Architect in WA State
W
J
Q
REVISION LOG
REV # DATE
STATUS
DPS PERMIT NUMBER:
BNA Project number:
DRAWN BY:
SHEET NAME
SHEET NO.
w
z ° a
0 0 �
J J J
m m m
RESUB
Oct 03 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
w m
m
w
w w
Z U
w z w
U z a
Q
DESCRIPTION
COVER SHEET
G001
PERMIT
Scale As indicated
i
0
N
M
O
in
N
O
c
c
Q
J
Q
Z
W
0
V1
W
O
U
.o
0_
E
O
U
n3
c:
a)
0
N
c
O
c
E
n3
U cl�66
J ~
LL d
ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS
W
Q
1
HOLY ROSARY SCHOOL
�CL
I II I
0 I \ / o I
I
o
I/
DALEY01MCC 1
103 91st Ave SE, Lake 4254780327
Stevens. WA 98258
www.drift-ia.com
I ° I
/
I
°
I
Registered Architect in WA State
W
J
Q
r U)
U U)
w HLu
z O
of of
w w w
0 0 0
D D
m m Co
w U)
Lu
w
w w
a�
Z U
/ W Z
U w
\ \ z a
/ O I / / \ REVISION LOG
I I /
REV # DATE DESCRIPTION
STATUS
DPS PERMIT NUMBER:
BNA Project number:
DRAWN BY:
SHEET NAME
SITE PLAN
SHEET NO
A001
1:18111
Author
Scale
191 = 201-011
ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS
W
FIRST FLOOR NEW
1 /4" = 1'-0"
WIC
k MASTEF
t BATH
F7
LJ rl��
Es
RY
TH 2
FIRST FLOOR DEMO
1 /4" = 1'-0"
kL
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED
SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED.
2. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF
1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE
2x6 STUDS AT PLUMBING WALLS.
3. 50 CFM EXHAUST FAN AT ALL NEW BATHROOMS
4. CONTRACTOR WILL APPLY FOR PLUMBING, MECHANICAL, ELECTRICAL
PERMITS SEPARATLY.
6. DOOR JAMBS SHALL BE 3 1/2" TYPICAL UNLESS OTHERWISE NOTES
7. CONTRACTOR TO VERIFY TO INSPECTOR PRIOR TO FINAL DEMO
INSPECTION, LOCATION, AND CONFIRMATION OF NON-STRUCTURAL
DEMOED WALLS.
8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING
WIRING WITH BATTERY BACK-UP. WIRING SHALL BE PERMANENT AND
WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED
FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE
INTERCONNECTED AND COMPLY WITH HOUSEHOLD FIRE WARNING
EQUIPMENT PROVISIONS OF NFPA 72. CONTRACTOR TO PULL FIRE ALARM
PERMIT FOR APPROPRIATE FIRE ALARM SYSTEM INSTALLER.
9. KITCHEN EXHAUST FAN TO BE A MINIMUM OF 100 CFM
10. BATHROOM EXHAUST FAN TO BE A MINIMUM OF 50 CFM
11. ALL OUTLETS SHOWN ARE CONVENIENCE OUTLETS, CODE COMPLIANT
OUTLETS TO BE INSTALLED PER ELECTRIAL CODE
- NEW CONSTRUCTION
EXISTING TO REMAIN
FLOOR PLAN KEYNOTES
103 91st Ave SE, Lake 1 4254780327
Stevens. WA 98258
www.drift-ia.com
Registered Architect in WA State
W r U)
U U)
Q W
Lu
z O
D D
w w w
0 0 0
m m Co
U)
w U)
Lu
w
w w o
a� a
Z U
W -7 W
Z of
U a
Q
REVISION LOG
REV # DATE DESCRIPTION
1 1 Date 1 1 Revision 1
STATUS:
PERMIT
DPS PERMIT NUMBER:
BNA Project number:
XXXI)=
DRAWN BY:
Author
SHEET NAME
SHEET NO.
FLOOR PLAN
Scale
1 /4" = 1'-0"
ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS
1
I
1
a
Ii
RENDERINGS NOT FINAL
—.-Aft
+ •�y d .iy.r�h •�f.• S
,T
�I
2 2 z ° m A v D m m D B
`° m m v < G m
z z Z ° A (n m W
O D fD uu
m c Z Z 3
T 717
n wm G) CD DALEY >
N
> W
m� r- � 1
z 00
00�
m h nO CLIENT NAME
BUILDER NAME
Z o ANN MEYERS o
G) C)
Cn lI
BUILDER CONTACT
V
O PROJECT ADDRESS W l J
O
Z w
D m XXX
c
3 � BUILDER ADDRESS
O
.OT DATE: 10/2/2023 8:18:13 PM FILE C:\Users\jennifertamblin\OneDrive - drift-ia.com\Projects\01 RESIDENTIAL\Ann Meyers\03 Revit\01 Work\D-IA-Ann Meyers-SD-RO-V23 OPTION
PATH: 2. rvt
FIRST FLOOR
1/4" = 1'-0"
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED
SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED.
2. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF
1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE
2x6 STUDS AT PLUMBING WALLS.
3. 50 CFM EXHAUST FAN AT ALL NEW BATHROOMS
4. CONTRACTOR WILL APPLY FOR PLUMBING, MECHANICAL, ELECTRICAL
PERMITS SEPARATLY.
6. DOOR JAMBS SHALL BE 3 1/2" TYPICAL UNLESS OTHERWISE NOTES
7. CONTRACTOR TO VERIFY TO INSPECTOR PRIOR TO FINAL DEMO
INSPECTION, LOCATION, AND CONFIRMATION OF NON-STRUCTURAL
DEMOED WALLS.
8. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING
WIRING WITH BATTERY BACK-UP. WIRING SHALL BE PERMANENT AND
WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED
FOR OVERCURRENT PROTECTION. SMOKE ALARMS SHALL BE
INTERCONNECTED AND COMPLY WITH HOUSEHOLD FIRE WARNING
EQUIPMENT PROVISIONS OF NFPA 72. CONTRACTOR TO PULL FIRE ALARM
PERMIT FOR APPROPRIATE FIRE ALARM SYSTEM INSTALLER.
9. KITCHEN EXHAUST FAN TO BE A MINIMUM OF 100 CFM
10. BATHROOM EXHAUST FAN TO BE A MINIMUM OF 50 CFM
11. ALL OUTLETS SHOWN ARE CONVENIENCE OUTLETS, CODE COMPLIANT
OUTLETS TO BE INSTALLED PER ELECTRIAL CODE
- NEW CONSTRUCTION
EXISTING TO REMAIN
FLOOR PLAN KEYNOTES
103 91st Ave SE, Lake 1 4254780327
Stevens. WA 98258
www.drift-ia.com
Registered Architect in WA State
W r U)
U U)
Q W
z O
D D
w w w
0 0 0
m m m
U)
w U)
Lu
w
w w o
a� a
Z U
W -7 W
Z of
U a
Q
REVISION LOG
REV # DATE DESCRIPTION
STATUS:
PERMIT
DPS PERMIT NUMBER:
BNA Project number:
XXXOM
DRAWN BY:
Author
SHEET NAME
SHEET NO.
CEILING PLAN
Scale
Al 02
1 /4" = 1'-0" 1
ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS
ELEVATION GENERAL NOTES
ISLAND 2
1/2" = 1'-019
KITCHEN 1
KITCHEN 2
1 /2" = 1'-0"
1� (L 1�
EQ EQ EQ EQ
0
OPEN SHELF
0
112' 1'-4114"
2'-8"
2'-8"
�•-6"
�•-6"
ISLAND
1 /2" = 1'-0"
CE li-
PULL OUTS TRASH
DKIFT
INTERIOR ARCHITECTURE
103 91st Ave SE, Lake 4254780327
Stevens. WA 98258
www.drift-ia.com
Registered Architect in WA State
GM
W r U)
U U)
Q W
Lu
z O
Of Of w
0 0 0
J_ J_ J_
D D
m m Co
U)
W U)
Lu
W
`
r
W W C)
a� a
Z U
W -7 W
Z a
U
Q
REVISION LOG
REV # DATE DESCRIPTION
STATUS: PERMIT
DPS PERMIT NUMBER:
BNA Project number: XXXI) =
DRAWN BY: Author
SHEET NAME
BUILDING ELEVATION
SHEET NO.
1 /2" = 1'-0"
ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS