Loading...
APPROVED RESUB1 BLD2023-1107+Structural_PLANS+10.2.2023_8.22.34_PM+3817204FLOOR PLAN GENERAL NOTES I I I I I I I I I I I I I I I I I I 1 I I I I I I I I L N CL -1 73'-,7112," NO NEW OPENINGS IN THE EXTERIOR WALLS. REMOVED FROM SCOPE FOLLOWING SELECTIVE DEMO TO FIND THAT THERE IS NO PLYWOOD SHEATHING AT THE EXTERIOR OF THE RESIDENCE --EXISTING LATERAL SYSTEM IS UNKNOWN. U 0 -fib O�MwBEARING WALL I/ / � � � � � � � RL (ORANGE) r SES TION FIRST FLOOR NEW IF_-1I L7�j Es NEW 4x4 POST OR (3) 2x STUDS. INSTALL BLKG & (N) FOOTING BELOW PER 4/S2.0. HUCQ410-SDS HANGER I� II II ; NEW 5.25x9.5" LVL BEAM —I I — — — L- _-I-- ='1_-- NEW (3) 2x STUDS IN (E) WALL. VERIFY (E) FOOTING BELOW GARAGE WALL 2x4 TRUSSES THIS SECTION FIRST FLOOR DEMO 1'-0" \4,J 1 /4" = 1'-0" L- i 2x4 TRUSSES THIS SECTION, CLEAR SPAN CONFIRM THAT TRUSSES CLEAR SPAN THIS AREA. NO RETROFITS REQUIRED FOR INTERIOR WALL REMOVAL AS HIGHLIGHTED IN YELLOW 13'-9 TYPICAL REMODEL CONSTRUCTION NOTES: • CONTRACTOR MUST REVIEW STRUCTURAL DRAWINGS PRIOR TO CONSTRUCTION & NOTIFY DESIGN TEAM/OWNER OF ANY DISCREPANCY IN COMPARISON WITH ARCHITECTURAL DOCUMENTS OR FIELD CONDITIONS. • CONTRACTOR MUST FIELD VERIFY & NOTIFY DESIGN TEAM/OWNER OF EXISTING MECHANICAL, PLUMBING, AND ELECTRICAL LINES THAT MAY INTERFERE WITH STRUCTURAL WORK PRIOR TO CONSTRUCTION. STRUCTURAL DRAWINGS MAY NOT REFLECT ALL EXISTING FRAMING CONDITIONS DUE TO LIMITED AVAILABILITY OF INFORMATION. • CONTRACTOR IS SOLELY RESPONSIBLE IN PROVIDING PROPER TEMPORARY SHORING PRIOR TO REMOVING ANY STRUCTURAL ELEMENTS. • ENGINEER IS NOT RESPONSIBLE FOR WATERPROOFING SYSTEM OR DETAILS. CONTRACTOR/OWNER SHALL CONSULT WITH QUALIFIED PROFESSIONALS AS REQUIRED. 1. ALL NEW FRAMING TO BE MINIMUM GRADE HF #2. 2. LVL BEAMS TO BE VERSALAM 2800, SIMILAR, OR BETTER. 3. NEW CONCRETE TO BE 2,500 PSI WITH 60 KSI REBAR. 4. ALL CONNECTORS IN CONTACT WITH CONCRETE OR TREATED WOOD TO BE GALVANIZED OR STAINLESS. EXISTING (2) 2x8 CEILING JOISTS FRAMED OVER LIVING IF SPACE. DO NOT APPEAR STRUCTURAL BASED ON EXISTING PLANS AND PHOTOS PROVIDED. CONTRACTOR TO FIELD VERIFY ----------------------------- , See sheet 6 of 10 in the structural calculations. The z NEW 3.5 x 9.5 ceiling joist are to be (2) 2x LVL BEAM ! material. The calculations show a 2x6 please verify member size and ensure that the ceiling joist are doubled as per structural ; calculation packet. --------------------------------- NEW 4x4 POST OR (3) 2x STUDS IN WALL. SEE NEW CONSTRUCTION DETAILS 11 & 12/S2.2 FOR CONNECTION TO (E) RIM EXISTING TO REMAIN AND NEW FOOTING BELOW DEMO CEILING T OCATE BEAMS, POSSIBLE REFRAME CEILING T EMOVE DROPPED CEILING PONY WALL BELOW RIDGE SITTING ON BEAM G SUPPORT RAFTERS.ICEIL CEILING JOISTS OVER TOHE KEYNOTES KITCHEN SPACE ARE FRAMED INTO THE TOP OF THE EXISTING WALL AND ARE NOT CONNECTED TO THE EXISTING ROOF RAFTERS APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE The following documentation shall be available on = ■ site for the building inspector: ; - ■ ■ xJ COE APPROVED ARCHITECTURAL PLAN SET - ■ x❑ COE APPROVED STRUCTURAL PLAN SET ■ x] COE REVIEWED CALCULATION PACKET ❑ ENERGY CREDIT WORKSHEET ■ ❑ SITE PLAN ❑ CIVIL PLAN ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■ DKJFT�-7""' INTEKIOK ARCHITECTURE 103 91st Ave SE, Lake 4254780327 Stevens. WA 98258 www.drift-ia.com 08/31 /2023 HAREZLAK ENGINEERING HAREZLAK ENGINEERING 11745 87th Ave. S. Seattle, WA 98178 PH: 360.224.0627 E: phiI@harezIakenqineerin2= W F U) a 0 Z ° a W W W 0 0 0 Co 00 00 Co BLD2023-1107 REVISION LOG REV # DATE STATUS DPS PERMIT NUMBER: BNA Project number: DRAWN BY: SHEET NAME SHEET NO. RESUB Oct 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT U) ry w U) U)� W W w 0 a2E Z U F- Z Z Lu Z U a Q DESCRIPTION FLOOR PLAN S1.0 Author 0 Scale 1 /4" = 1'-01, ORIGINAL DRAWING SIZE IS 36" X 24" DO NOT SCALE DRAWINGS FOR MEASUREMENTS Architect Project HAREZLAK ENGINEERING 717 DALEY RESIDENCE STRUCTURAL DETAILS (N) POST PER PLAN IN EXISTING STUD WALL. TOE NAIL TO (E) BOTTOM PLATE ;E) FRAMING BELOW POST TO BE FIELD VERIFIED (N) AC4Z POST CAP (N) 4x4 POST DIRECTLY BELOW (N) POST ABOVE (N) 24" SQ x 10" DP CONC. FTG w/ (3) #4 EW BOTTOM BEARING SOIL CONDITIONS PREPARED BY OTHERS 08/31 /2023 Sheet of Job No. Date 08/31 /2023 Engineer PAH (N) 4x BLKG TO MATCH WIDTH OF POST ABOVE; NAIL THRU ADJACENT JOIST w/ (3) 16d TYP. (N) ABA44Z POST BASE w/ 1/2" DIAMETER x 6" TITEN HD ANCHOR (E) 2x4 PONY WALL ABOVE, CONTRACTOR TO RE -USE EXISTING FRAMING OR PROVIDE (N) 2x4 PLATE AND NAIL PLATE TO (N) BEAM w/ 10d @ 6" OC. VERIFY AND/OR INSTALL (N) TOE NAIL CONNECTIONS BETWEEN EXISITNG RAFTERS AND (E) TOP PLATE (E) (2) 2x8 AND CEILING JOIEE FRAME INTO NEW BEAM. PROVIDE LUS28-2 HANGER, DOUBLE JOIST AND LUS28 HANGER AT TYPICAL CEILING JOIST (N) CEILING JOIST TO BE MIN. 2x6 @ 24" OC w/ LUS HANGER TO (N) BEAM. FRAME CEILING JOIST TO (E) RAFTER w/ (3) 10d EA. AT BEARING WALL V) 3.5x9.5 LVL BEAM PER 'LAN. BEARING LOCATIONS BEYOND, PER PLAN NOTE: 1. CONTRACTOR TO PROVIDE SHORING FOR UNSUPPORTED ROOF SECTIONS DURING NEW BEAM INSTALLATION. S2.0 11745 87th AVE S. SEATTLE, WA 98178 360.224.0627 HAREZLAK ENGINEERING Architect Project _ 717 DALEY RESIDENCE STRUCTURAL DETAILS (N) POST IN WALL ABOVE PER P (E) FLOOR FRAMING CANTILEVERS FOUNDATION BELOW (N) BLKG TO FILL WIDTH OF WALL A x DEPTH OF EXIST FLOOR JOIST w/ (3 NAILS TO EXISTINI JOIST PT 4X4 POST BELC SEE 12/S2.1 FOI FOUNDATION CONNECTION NOTE: 1. ADDITIONAL WATERPROOFING, WRAPPING, DRAINAGE FOR POST AND STRUCTURE BY OTHERS Sheet of Job No. Date 08/31 /2023 Engineer PAH (N) PC4Z POST CAP FROM (N) POST BELOW TO (N) RIM AND BLKG ABOVE. #3 TIES @ 6" O.C.; (2) AT TOP (4) #4 VERT. NOTES: FASTEN ALL SIMPSON HARDWARE PER MFR. SPEC. 44 POST PROVIDE%" O x 6" EXPANSION BOLT 08/31 /2023 POST PER PLAN SIMPSON ABA POST BASE w/ EXPANSION BOLT PER MFR. %" CHAMFER PLINTH EDGES T/ PLINTH z T/ GRADE VARIES B/ FTG.� 24" SQ. x 10" DEEP w/ (3) #4 BOTTOM S2ml 11745 87th AVE S. SEATTLE, WA 98178 360.224.0627