Loading...
APPROVED BLD2023-1220+MECHANCAL PLANS +9.29.2023_3.32.27_PM+3813556ALL DETAILS ARE NUMBERED VICINITY MAP SYMBOLS & MATERIALS rim r, n rr�i.r �r CUT (TYP.) DETAIL NUMBER (TYP.) SHEET DETAIL IS SHOWN ON (TYP.) HSS COLUMN FOOTING -0" FLOOR PLAN 3/32"=1'-0" GENERAL NOTES OPEN SINGLE ARROW INDICATES DIRECTION OF 1 A9 3 1 A9 A9 2 A9 MULTIPLE ELEVATIONS, ADD PORTIONS OFSINGLE INTERIOR ELEVATION. FOOPEN ARROWS 4 2 AS NEEDED TO DEPICT THE REQUIRED ELEVATIONS & ADD THE DETAIL NUMBER FOR ELEVATIONS SHOWN ALL INTERIOR ELEVATIONS ARE NUMBERED ON INTERIOR ELEVATION TITLE, PLACE ONLY A SINGLE, OPEN ARROW AS SHOWN LEFT ELEVATION 3/32"=1'-O" E*1 DETAIL CUT DETAIL TITLE W/ SCALE SHEET TITLES W/ SCALE SCHEDULE TITLE INTERIOR WALL ELEVATION CALL -OUTS ON PLANS INTERIOR ELEVATION TITLE W/ SCALE PRODUCE CASES FOR STORE NO., 136 EDMONDS, WASHINGTON CONTACTS THE FOLLOWING FIRMS DEVELOPED THE BUILDING CONSTRUCTION DOCUMENTS ARCHITECT: b.hills architecture, P.C. 3156 S. BOWN WAY BOISE, IDAHO 83706 PHONE: 208-258-6155 CONTACT: RYAN BARNETT EMAIL: rbarnett@bhillsarch.com Ci CH CG CF CD OWNER: WINCO FOODS, LLC 650 N. ARMSTRONG PLACE BOISE, IDAHO 83704 PHONE: 208-377-0110 CONTACT: MIKE TRAN, FACILITIES PM EMAIL: Michael.Tran@wincofoods.com PLUMBING ENGINEER: DC ENGINEERING 440 E. CORPORATE DR. #103 MERIDIAN, ID 83642 PHONE: 208-288-2181 CONTACT: ROGER DEAN EMAIL: rdean@dcengineering.net ELECTRICAL ENGINEER: DC ENGINEERING 440 E. CORPORATE DR. #103 MERIDIAN, ID 83642 PHONE: 208-288-2181 CONTACT: BILL CRABB EMAIL: bcrabb@dcengineering.net n n n n n n (10 n1I n12 --- ----------,---- --- +_--�, ____ -----=T=--------- ----- =T T--------__-___ ___ ____ ___ ________ ___ �LLLLLL'LLLLLL'LLLLL LL LL LLLLLL _ _ j H` H n n T T T _ =: - I }�� .}..}..}..}..}..}..}. Y�i�li 1 1 rYq �4a }•_i__i__ __i__i__i__1__ ( I I I I I I 1 1 1 1 Irt L"t Fill I Imi h I II 9 ] c Ii H I� JJ II JJ ��-__---__ n u— nm by u F27 ❑ rtY r� k uv 1 2 3 4 5 6 7 8 9 (�O) 11 12 ORT NORTH ARROW OVERALL FLOOR PLAN KEYED NOTE 1 " = 50'-0" O MATERIAL CALL -OUT OFINISH AND/OR COLOR CALL -OUT OL 1001-01, DATUM ELEVATION TARGET ABOVE LINE, TOP OF xxx BEAM, FINISH FLOOR, ETC. BELOW LINE GRID BUBBLE AND LINE Gri PLAN DEMOLISH OR NEW EXISTING RELOCATE i 7 CMU WALL COOLER / FREEZER BOX ____________________ _ _ _ _ PARTITION WALL SUSPENDED PARTITION WALL -------------------- y CONCRETE ------------ CODE INFORMATION CODES 2018 WASHINGTON STATE BUILDING CODE 2018 WASHINGTON STATE FIRE CODE 2018 WASHINGTON STATE ENERGY CODE NATIONAL ELECTRICAL CODE 2020 OF WASHINGTON 2018 WASHINGTON STATE PLUMBING CODE 2018 WASHINGTON STATE MECHANICAL CODE OCCUPANCY GROUP MERCANTILE GROUP M (NO CHANGE) CONSTRUCTION TYPE TYPE VB - FULLY SPRINKLERED (NO CHANGE) OCCUPANT LOAD CALCULATION (TABLE 1004.1.1) TOTAL BUILDING AREA = 98,452 SF (NO CHANGE) EXISTING OCCUPANT LOAD = 2,394 (NO CHANGE) REFRIGERATION ENGINEER: DC ENGINEERING 440 E. CORPORATE DR. #103 MERIDIAN, ID 83642 PHONE: 208-288-2181 CONTACT: GREG HANSEN EMAIL: ghansen@dcengineering.net 3J DH DF DD SHADED AREA DENOTES APPROXIMATE AREA OF PARTIAL PLANS ABBREVIATIONS A.F.F. ABOVE FINISHED FLOOR A.H.J. AUTHORITY HAVING JURISDICTION A.O.R. ARCHITECT OF RECORD & AND B.O. BOTTOM OF CL OR C.L. CENTER LINE CMU CONCRETE MASONRY UNIT CONC. CONCRETE CONTR. CONTRACTOR (D) DEMOLISH DIM. DIMENSION (E) EXISTING E.O.R. ENGINEER OF RECORD F.F. FINISHED FLOOR F. FR. FACE OF FRAMING GYP. BD. GYPSUM BOARD (N) NEW NTS NOT TO SCALE RE: REFER TO (R) RELOCATE SPECS. SPECIFICATIONS S.S. STAINLESS STEEL (T) TEMPORARY T.O. TOP OF TYP. TYPICAL VER. VERIFY V.I.F. VERIFY IN FIELD SCOPE OF WORK — THE SCOPE OF WORK INCLUDES THE ITEMS LISTED BELOW: 1. INSTALL NEW MULTI -DECK PRODUCE CASE 2. INSTALL NEW SELF-CONTAINED CASE UNDER EXISTING PALLET RACKING. THIS REMODEL SCOPE OF WORK DOES NOT INCREASE OR DECREASE THE OVERALL SQUARE FOOTAGE OF THE MAIN SALES AREA. DRAWING INDEX C1 COVER SHEET & OVERALL FLOOR PLAN FP 1 PARTIAL FIXTURE EQUIPMENT/ COODINATION PLAN AO PARTIAL DEMOLITION PLAN Al PARTIAL SLAB PLAN & DETAILS A13 PARTIAL MISC. FIXTURING PLAN & DETAILS A13.7 FIXTURE EQUIPMENT SCHEDULE & DETAILS PO P1 P2 P4 P5 EO E2 E7 RO RI R2 R3 R4 R5 PARTIAL PLUMBING DEMOLITION PLANS PARTIAL PLUMBING WASTE AND VENT PLAN PARTIAL DOMESTIC WATER PLAN PLUMBING SCHEDULE AND LEGEND PLUMBING DETAILS PARTIAL ELECTRICAL DEMO PLAN PARTIAL ELECTRICAL REFRIGERATION PLAN ELECTRICAL PANEL SHEDULES rEEEE PARTIAL REFRIGERATION DEMO PLAN PARTIALREFRIGERATION PLAN PARTIAL REFRIGERATION PIPING PLAN REFRIGERATION DETAILS REFRIGERATION SCHEDULE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE CONTROL IO POINTS APPROVED PLANS MUST BE ON JOB SITE New equipment shall comply with WSEC C410.2.2. Separate plumbing permit required. Please apply via MyBuildingPermit.Com City Of Edmonds Building Department Work MECHANICAL- PRODUCE CASES Address 21900HIGHWAY 99 Owner WINCO FOODS -------------------------------------------------------- ------------------- Approved Date 10/10/2023 ---------------------------- Building Official Erg C&rfer- ------------------------------------- Permit Number BLD2023-1220 ------------------------------------------------- REVISIONS DATE PAGES - CHANGES REV1 REV2 REV3 REV4 REV5 REVISIONS ARCH. PROJECT NO. 23043 DRAWN CB CHECKED RB SUBWrTAL DATES 09/29/2023 OTB DATE �o 0 zw� � yyyy E^p� hGa �S Vy �pA02U 6Z O� 2 a�r�a�77o�zo w 3wQ ci �GU� C rnF 0 e b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.258.6150 www.bhillsarch.com 10562 REGISTERED ARCHITECT BYRON T HILLS STATE OF WASHINGTON 09/29/2023 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT • � O C� o0 u� TV1u� O 1^1 L O ~ � H N W SHEET TITLE COVER SHEET & OVERALL FLOOR PLAN SHEET NOTE: ALL WORK SHOWN AND NOTED ON PLANS & DETAILS IS NEW UNLESS NOTED OTHERWISE, RE: ABBREVIATIONS FOR EXISTING, (E) & OTHER ABBREVIATIONS USED THROUGHOUT THE DRAWINGS. 9 9 10 11 12 II I ---------------- I� I , II I , I I ' I , I I ' I I I r T � � �\ < I I I T - I I Ixl I - ; � > I ) ;ors, ° V 0 I---------------------------------------------- ---------------------------------------------------II ---------------0 ------------------------------------------- ---T-------------------------------------------------- -- -------------------------------------------------r i i �i- I I II , I I� I I I I I I 'I I�.------� I' Ir---------------------------+--------------------------------------------------------------------A, III ____T_____________T_____________T------------- T------------- T------------- T_____________T__________ __- _r_ _i (E) 28'-6" M/D PRODUCE (MISTING) � II "I z �---= 'e U I I I I CN III li II I I I I ----L------------- 1-------------L------- L------- L-------------L------------- L---------- W J J N II a 0 'I a Z II ° Lu I I I Y II III I I j Z l ��yZ f�r�yIl O °-------L�`I W -�0D — W E Of 2 II (E) PRODUCE RACKS II .-. II J i i II II U II'oI a _____________-F_____T_____________T_____________T_____________ T_____________T_____________T_____"----- "----- "------ U---- , � PRODUCE n ----- n ----- n ----- n ----- 4-- , r-�Q ==================================== ====== -� IIIiI Ii I I I II I r ---- „ U U __, _._ �-3 IL --:" a DRY ROOMUJ — -- -fig w C----�-----------_ ILL ° ° ° °C - I I -- -- ------d ---------- ^ _ lIII l 1 n-----�n-----�n nII W F� iii I (E) PRODUCE RACKS jl I I, -_ E HAND DRYER _ E)" HAND SINK T------------ T------------- T-------------T-------------T-------------T----------------------(E) I SOAP -==---------- ---- -------- ------- ' ----- ---- ----------- ---- -I --------------I -------------I -----------------I ---------- I --------- -I MAIN DISPENSER- - --------I--------I--- -------- _---_-�-- ---=v-=-----'---- �'II - I r-----"__=-===T =_ I I I I I I SALES ------------- i_____________L_____________L_____________L_____________L_____________L---------- _ j I, I II I I II I (E) PRODUCE RACKS ___- _{ Y I- "' PALLET PALLET ' ' PALLET 1I' ° Y '' I �a IIL 1c : _- c--=-==--= 3uC,iruJlI4 nIIn_II ______ __nnIn_I �JIIr W Wa�a Uaa __�_- --__-_ _------- Ell- � ------------------- ----�-- --- -a --- --- -- ----- - --- in-------------__-__t TI�I�IIIIiI'III T,,�'�,'••, ------------ in t ----- -F----- ji O Z CZWW _-_--n-- ----=-- ----------- r-1n--x-----_n -- -----I----II�I --n----- W V-V -----------V-------------u------------n u-------------7 ____ _ ---- ----- (E) II iI IiIIIIIII;1iIII;IIII� iIIIII� II"II IIIIIIIIII'III iIlII' IilIIllII� 'IIiI�'liiII II PRODUCE RACKS I II I I I, II E) PRODUCE COOLER /�/^ V I I, z II 11 I II I Y ; I I, (DD — — ter- — — ° TII D I II I a I I, I II I N � 111 II I •w I I, L~LI --------------------- i------------- - — ------ ;II a II _____________________ -____ ° LO (E) PRODUCE RACKS Q� II II II IiIi �Y I c W TII lI'• 0 Z r wVaW " co Z a U II II VNW 1lI,i,I I a, O U asN c-� i==� c==a�'4_____n_____�4_____n_____�4_____n_____�4_____n_____ 4_____n_____�' � 2 NON U----------------------- II ---------------------------------------------------------------------lIIf----------------- IIIIII =- --- - - �n IIIIII ° J, w ---------------------- ,I -----i----- --------- O d---_.1w -jr ___ --------------------- -----------------=======r=rr=rC=-- ,f----- =U 1 I „ Z- -_--'nqli�--------- wo ___�- -- _-- LLc I ,IIIII III III III ,I II� a II III I II IIII lir ®,,�'i1 IIII' o - " IIILL III (E) 1 _ „ 9 KING III ._._._ �.If if if if f i'� 2' 6 PALLET RA ;I4--n-----�4-----n-----�4-----n----�4-----n---- 4-----n-----�' - II III ._19°°I I I I I I I o I I I - w II , I I �i II II � I 11 oo 2 92' & 1 4 I w - — I I I I' Q� '_-- I -- _lk_ I I - — _ ____-____ ____-___ ____-____ ____ _ __ _ __ _ __ EV I" -- J -;' I I I (E) PRODUCE RACKS III I, I I II I II I1 II I I, I ---------------- I I I I III II II �� III I I, I I II I I I; I I II I I I, I I, I' II II iri i l IIL�___________________________________________ __________________�J tea; I I I I I ' I ' I ; ---------------------------------------------------------------------------------------------------- <» (E) PRODUCE RACKS ---------------- --------- -- - _ --------------------------------------r----- ------------- ---- �I ------- -------- -- I --- -- -- -- ___ �- II - _-- -- -------- �-------- ----__ - II W� '--------�.-FF--------�>';4'.-FF---------n------- ->;4�'---------n--------- �4�F---------n -------- -i,;'', W U -----UI----- U ----- 2-----n-----4-----n----- U U U = rCI, ------------1 �1" ------------------- W II W -----_�-__ _- ________________________________----- ____________________________________ --------------- __ a ----------------- ------------------------- 1 -------------------- �___------_--------------------------�_------------------ ILL m� II I I� �4---n-- IriI;; w _� _ - --- _ _ a ? _ mw� O µ- � - �O II I zZJ4 - JJJp [-=d====JJq[ ---- J L==== ---- J L==- J L==== -------------------------- ---------------------- -----------------------------'-------------- __� d�1------4'-------3------------------ --------- --------- `--------- E-'L'----�--i5 ----------------------------------------------------------------------------------------------------- - --------------------------------------- - ------ -------- - ---- «» (E) PRODUCE RACKS I, I I, I I I '• I I, I, I I, I I, I I, I I, I I, I, I I, I I, I I, I, I I, I I, I I, I I, I I, I (E) 12--9" (5) DOORS (E) 12'-4" (6) DOORS FROZEN FOOD O�r�P ` MED. TEMP. DELI /D PRODUCE (JUICE MERCHMSALAD DRESSING) ___________ ____ ___ ________ __ _______1_____ __ _____IC_r F+ ------------ I ; II I ';IIII ;II I, I I I I II II it I u L I ,I ' II I I I *k=== _ 9 _ __________ _____ _____ --------------------------------------------------------- ------------------------------- C — - — - — - -- - - - — T--TnT-- - ---_--_-_--_ - __ --__---__--_ -- _-_ _---__--- ------ --- -------__------ —--------- ---- — -� --- --- --- — T_ , - I I� II II I II II II II II II 9 10 11 FOR REFERENCE ONLY PARTIAL FIXTURE EQUIPMENT/ COODINATION PLAN 3/16" = 1'-0" REAR LEFT OgT RIGHT MIM32411111M REVISIONS ARCH. PROJECT NO. 23043 DRAWN RB CHECKED BTH SUBMUTAL DATES 09/29/2023 _+_ OTB DATE �lo 8 zw� 0E, yyyy OO°a'Oaa'U6a'O© Uw��`AO2� 2 0 a�r�a�77o�zo 3wQp ci �w 5 VGoow. 9¢0I;���F 0 • a� e b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.2586150 www.bhillsarch.com 10562 REGISTERED ARCHITECT v:E!H SHINGTON 09/29/2023 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT ^ r� N rC I� O O O u O N W SHEET TITLE PARTIAL FIXTURE EQUIPMENT/ COODINATION PLAN SHEET 9 9_-_ -___— i _Ir�y1J1_AVIj -rI-, -_---_IIIIIIiIIIIIi_'I T}1t1l�_],1tlC I + 1__'IIIII0 ���i��44I;IIT 1 n -1;1'�l�ir',', I7„,e'��•7 ---- - rI -� a—�nLWQ0Ud-L/-_YQ ` WmCGUW_ Gs` �0wg—q !VzLLcGio�—\nU�LLap� !1- �ii1l11,1IIIIIIIIIIIIIILIIIIiIIIIIII�I�I�IIIIIIIIIIIIIIIIIIIIIIIIIII , ---]=-�— ---J -- =- i:II':,II �CII�;iIII,�II'IjIIIIIII,,II,iIIIIIIIIIIIIIIIBIII�IIIIiiIIIIIIIIIIIIIIIIIiIII,II�iII,I�III -1-1I�iIIIIiiI�II',IIIII'IIIIII,,�I,,II'IIIIII,III,IIIIIIIII,III�IIII,III'I'IIIII,I�I�''���''IIII'IIIIII�IIII�III�III�IIIIII �1 3 vT------------- T------------- T------------ ----- _--- _---- ______ -------------- T—T IN I III — — ------------'-------------------------1------------------------------------------------ � ------------------------ }---------------------------+---------------___________===== Lj ___T__________ __l4 (E)28'-6" M/D PRODUCE (MISTING)T_____________T_____________T_____________T_____________T_____________T__________r'z ------------- 1------------- 1------------- J------------- J------------- J------------- J---------- __JW z 0OD (E) PRODUCE RACKS T T T T T T T __l _ L_____'_L___ _L_____' _L_____ _J____ - n n n n —- -- _ === == I = ______ =-----U----- ---- ----- --- _-----_--- �wQ _d ---_-_w _-_--_-� _____________ _______________ ------- ------- _ II o � z O Z OW e-----n---- W -=LLIL0_ LL-----iLL-- iLL-----fU-----I n-----�n-----�n----- 4-----n-----Y4---n (E) PRODUCE RACKS T T -- MAIN = _====�_====�====== SALES ------------- y------------- ------------- i------------- ------------- ------------- ------------- (E) PRODUCE RACKS (E) (E) (E) -__ T PALLET PALLET PALLETif U -----n----- -----n-----DROP DROP DROP ;;c==c==i c, LLI x -----------.Fr.---------. WQ UU __- ------------ ----- - _--- : = -----------n-------------n-------------n-------------m-------------R=====� _�........ -----.... �Z -- `�----IW�"--- �-----------� W f----- --- -n-----n-----n--- - u w -----------u-------- ------------- u '--'4' (E) PRODUCE RACKS --------------------------------------------------------------------------------- ---- - f --------------------- -(E) PRODUCE RACKS -------------- -------------- -a- _- -J --- U Q U-A: O----IL --------=__________ ============----fJ---»i Q_ -- --------- -- ----------------------- ----------------------- ----------- -------------------------- --------- ___ -------- --------- z n_...-... Elf ... ..... W -_- -----n------ --T- LL - __L_____�- --J__ _-� WO Li III n �4 n �4 n 4 n n ---------------------- -.C===== --------------------------------------- (E) PRODUCE RACKS L4 _ _ _ _------------ T __ __ E PRODUCE RAKS W --------- ILL -----n-----4-----n----- n --- 00 � __ LFw ---------------------------------------------------------------------------_ ------------------------ d __ _______________________- ________________________________________________________ : --___ -___- _ =___- __ ________ ---------- a O ---- of---- oW O---------- n----- n ---- n ----1 (E) PRODUCE RACKS � (E) 12--T (5) DOORS (E) 12'-4" (6) DOORS 0FROZEN FOOD MED. TEMP. DELI PRODUCE Q� (JUICE MERCHSAAD DRESSING) __________ ___________-______ ___------------------------------ ---------------------- ---------- --------------------------- _____________________________________________L ______________________________________L __________________________ __________________________ ___________________________________________ _�tIIIIlt"II"IIIIIIIIIIIIIIIIIIIIIIIIIII'IIIIIII'IIIIIIIIIIIIIrIIIIIIIIIIIIIIII',IIIII ------------------------------------------- _1rIIIlIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII�IIIIIIIIIIIIIIIIIIL- _ -___- - -__ I __—___—____—____—___—____—____—____—___—____—____—___—____—__ ____________________________________________________________________________________________________________________________________________________________ __ ________- .-______________________ ________________________________________________________________J 'I I' � 'I I' I II 'I I' II II 'I I' II II 'I I' II II 'I I' 'I I' II II PARTIAL DEMOLITION PLAN �&-A 9 10 11 3/16" = 1'-0" GENERAL NOTES 1. THIS PLAN SHOWS GENERAL DEMOLITION WORK TO BE PERFORMED AND DOES NOT RELIEVE THE CONTRACTOR FROM OTHER DEMOLITION WORK REQUIRED TO PRODUCE THE BUILDING MODIFICATIONS SHOWN ON THE REMAINING CONTRACT DOCUMENTS. THE CONTRACTOR SHALL COORDINATE AND VERIFY THE ENTIRE DEMOLITION SCOPE WITH THE ARCHITECT OF RECORD AND WINCO PROJECT MANAGER. 2. PROTECT ALL EXISTING ELEMENTS SHOWN TO REMAIN FROM DAMAGE DURING CONSTRUCTION, FOR THE EXTENT OF THE DEMOLITION AND MODIFICATION. PROVIDE A TEMPORARY DUST PARTITION TO PREVENT DUST AND DEBRIS FROM SETTLING ON ADJACENT AREAS NOT UNDER CONSTRUCTION AND AS DIRECTED, REVIEWED AND APPROVED BY THE WINCO CONSTRUCTION MANAGER. 3. CONTRACTOR SALVAGE ITEMS SHALL BE DISPOSED OF PROPERLY OFF SITE AND IN A EXPEDITIOUS MANNER. 4. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE CONTRACTOR'S BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, (UNLESS A SEQUENCE IS SPECIFIED BY THE OWNER OR CONTRACT DOCUMENTS) AND PROCEDURES, AND FOR COORDINATING ALL PORTIONS OF THE WORK 5. REFER TO THE PLUMBING, ELECTRICAL AND REFRIGERATION DRAWINGS FOR ADDITIONAL SCOPE. 6. METHODS AND SEQUENCE OF WORK AS RELATED TO STORE OPERATIONS ARE SUBJECT TO APPROVAL BY OWNER. 7. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL VISIT THE SITE TO — E BECOME FAMILIAR WITH ALL CONDITIONS THAT AFFECT ALL PORTIONS OF THE WORK. COORDINATE WITH OWNER TO SCHEDULE TIME AND DATE FOR SITE VISIT. 8. CONTRACTOR SHALL COMPLETE AND SUBMIT TO OWNER A DISPOSED EQUIPMENT LOG TO INCLUDE DESCRIPTION, MODEL, AND SERIAL NUMBERS OF ALL EQUIPMENT AND FIXTURES REMOVED AS A RESULT OF THE WORK, RE: PROJECT MANUAL FOR LOG FORM. 9. CONTRACTOR SHALL PATCH ANY HOLES OR PENETRATIONS MADE DURING CONSTRUCTION TO LIKE NEW CONDITION, COLOR & MATERIAL TO MATCH (E) ADJACENT FINISH, RE: SPEC. SECTIONS 017329 & 024119. KEYED NOTES 1. RELOCATE (E) PALLET RACK BEAMS, SHELVING & PALLET STOPS @ 106-10 3/8" TO 109'-4 3/8". VERIFY 24" MIN. CLEARANCE FROM T.O. CASE TO B.O. SHELVING 2. RELOCATE (E) MOBILE MERCHANDISER. COORDINATE W/ WINCO'S P.M. & STORE MANAGER FOR LOCATION 3. RELOCATE (E) CANTILEVERED SHELVING & BULK FOODS C RACKS TOWARDS RIGHT WALL AS NECESSARY TO ACCOMMODATE NEW PARTITION WALL, RE: FP & Al 4. SAWCUT (E) CONCRETE SLAB FOR FLOOR SINK AS INDICATED BY E<=, RE: Al & PI REVISIONS ARCH. PROJECT NO. 23043 DRAWN CHECKED BTH SUBMUTAL DATES 09/29/2023 OTB DATE �lo 8 zw� 0 E, V yyyy �Oaa U60.Q© V � Vy pQ�Z0 6Z6Z O� 2 a�r�a�77o�zo w 3wQ ci �GU� C rnF 0 z fxr�a�� V b c� e b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.2586150 www.bhittsarch.com 10562 REGISTERED ARCHITECT v:E!H SHINGTON 09/29/2023 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT r� Q O 0C �y1 1 O r� O O 1� N W SHEET TITLE PARTIAL DEMOLITION PLAN SHEET 9 10 11 I I I , _ - _----__- ---- - 1r 1r 1r 1r 1r 1r µ___________________y.________. --- - - - - s --- �- ------------------------- �' � ii IIIII i1i ii ii ii _ tll ,' II II II II II II ' Il--- - - - - -- , I _______1_____________1__________ __J C______2------ .L____________——_____--- J1--________ J1_ 1L1L1L- —_—'� sr �T—__—T�I� ----------------------------------------------- ------------------------------------------------------------------- T -n ��---- I I I ICT-� III . -------- '------------------------------------------------3 - 1 -1I 11I " --- I IIII I II - ---_ -tee ------------- ---------- --- - -1- 2 ' ---- - ---- ---- - ---- 1 I I II ,. I IIII II I I'I I , I Il III I'I III _ - _ t A r A q7 ; T------------- T-------------, i r--- ;f————--—————Sf u-----�"f u-----�'? u----- U ---- �'I L------ -� I = „ II ' I , __ _n_____44_____n_____44___ ------- 4 ——-- —— — t= __ — _ �, — — L L r - - -- - - ===== ====- = =-- ----= ----. ===== =_=== === = ===== -==== ~--- --------------------------- --- ------------- T—--——————--——T————— _ — — �1 —--——————--—— , I =-- L„ i II II Ln I I Im IIII III II II Ln I Lu I Ln I III Iln I Gs Im I I I I n----- 44_____ n_____4, === __ _ 41 [= i- - II __�...� I- -y- _, '-'TIP ____ _______-�_-_ „�. -i-+--------- 11 III 1=1. —3, c---- -----u---- -•---u---- �-----emu---------u-----�f- -u-- „4 u I-n----->;14- n ,i14-----n ,;4----- n----- 4-----n-----�'I ''d -r== u---- - - - - ------ - - - - ------ - - - - -J - - -- -u d d d ,„ I III II _ _ MIS-+-- -- lil ------------ --------------------------- s. ----- ,I I ,I - _ __ ` IIIIIf'�'�——— —fr ——— —— n----- �4_____n_____�4_____n_____�4_____n_____ 4_____n_____�'� I �_ �I — IJ— _ _ _ _ —— _______________ _____ ___�= —_____ ____=_ I r ----p-----�--------��---- -----��-- ---- �'_----A=-- u_____ u_ II III it®®�I '-----------'----------'kn----->;4-- n----- ,;4-----n----- ,;4-- --n --- 4--- -n-- -,;I� _ =d=== J = J = J ____________----------— __—�—___ _ _ _ �, r1 III II II I I N--+--------1 I II I ------ -- --- r_____________ _ ,I---__r--=T�7 u-----5'f----- a - - --- -----III -- ",� ----- --- --- -- ;; I� 4-----n -u----- u----- u----- --- II f---- f i� =--_----- ---- ice --- ---- _ 1 _ r _ --- u u ----—--—--———----—--—----——=__ _== ______=_ == 71 _=�;.. ________________________________________� ----—--—----—----—--—----—-- _ -- - --�-_ ,' , � -I @`�����;1 III I II II n-----,i14-----n----- ,;4-----n----- 4-----n-----,i;� „ d-- ------ --- ------------ «» c_)),I -------------------- ----- IC III �--________ ___I_____________�• ILL===§L=_ .............................................. ----- i------------- u� I Ln I Ln I u� I II Ln I 'II! IIIII IIIII L„ I 1 1 Lu II Ln I I I II Ii1 'I �u F==� - - - ,,I II ------------------ -T-- - II "I LL II III I'I I'I I 1 II ;; II II III III I Ij --;II-II -----------1II U----------------------- ----- =__________________________________________ZA=0 - - _--------------------------------------- ' --------- --— JI I I I I 1 II II — - - - — - - - — - - - - - - - — - - - - — - - - - — - - - - — - - - - — - - - - — - - - - — - - - - — - - - - — - - - - — - - - - — - - - - — - - - - — - - - ------------------------------ —____—__r_ �—T_ � 9 10 11 II II I I' I I' I I' I I' II I I' II I I' II I I' II II CONCRETE KEYED NOTES 1. (E) 5" CONCRETE SLAB/ FLOOR FINISH TO REMAIN 2. SAW CUT (E) SLAB. REMOVE CONCRETE FOR DRAIN. REPLACE W/ 5" GRAY CONCRETE AS INDICATED BY , RE: CONC. STRUCTURAL NOTES, THIS SHEET. IMPORT GRANULAR BASE TO MATCH (E) IF REQUIRED. EMBED 1/2" X 14" SMOOTH DOWELS @ F-0" O.C. INTO (E) SLAB TO TIE (N) SLAB TO (E). CONCRETE SHALL BE A HARD TROWEL FINISH, RE: Al-15 2, P1 & R1 3. FLOOR SINK CENTERED ON CASE TOE KICK, RE: P 1 BACKFILL/COMPACTION GUIDELINES: -MOISTURE CONDITION EXISTING ON SITE SOIL TO OPTIMUM MOISTURE CONTENT -USE A MAX LIFT HEIGHT OF 6" UTILIZING ON -SITE TRENCHED SOIL -COMPACT EACH LIFT TO A FIRM UNYIELDING CONDITION -PROVIDE 6" OF 3/4" MINUS CRUSHED AGGREGATE BASE DIRECTLY BELOW FLOOR SLAB, & COMPACT TO A FIRM UNYIELDING CONDITION FLOOR SLAB, DOWEL TO (E) SLAB, RE: Al-2 (E) FLOOR SLAB TRENCH 1 tt = I t-Ott PARTIAL SLAB PLAN 3/16" = F-0" COMPACTED BACKFILL 6" OF 3/4" MINUS CRUSHED BASE INTERIOR SLAB -ON -GRADE 1/2"XI4" SMOOTH DOWEL @ MID SLAB & @ F-0" O.C. W/ 4" EMBED INTO (E) SLAB. CONC. TRENCH PATCH 2 TRENCH PATCH 1 1 /2 = 1 -0 100 REVISIONS ARCH. PROJECT NO. 23043 DRAWN CHECKED BTH SUBMUTAL DATES 09/29/2023 OTB DATE cxJo x � yyyy OO°a'Oaa'U6a'O© V 0 2 a�r�a�o�zo w �WQ cc), �GUti go�x��oo e b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.2586150 www.bhittsarch.com 10562 REGISTERED ARCHITECT v:E!H SHINGTON 09/29/2023 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT INO • \/ 1 O O 0C Ir TI lI 1� O � � O O O N W SHEET TITLE PARTIAL SLAB PLAN & DETAILS SHEET 10 xTC)TPc - BOLLARDS SHALL BE PAINTED PRIMER GRAY - VERIFY ALL UNDERGROUND UTILITY LOCATION! BEFORE EXCAVATION. - GRIND SMOOTH ALL EXPOSED EDGES T T------- - ,�L=====_�-_-_--_ h I , II' I I I ,I I �,' ----------------------- - ---------------'�_____- T_____________ T__________ __l�- i I I I T_____________ T--------- , , I� I II I I I i > I ' I, I ------ �---- — -- — ---- — - r- — -------------- I, I I I 1 ==5„�--------- — -' _-__-_----_--_-__-_-__-_--=i7= I _ - -- _ _ ______________ ________________________====1 IIII IF--_l ; ••'I yyl yyl 4 �"� ___________I__________-______- - III I IIII I III II Ilp I III I , III �rf H -----------I ==_____-_ ---------- 1 un n;'i NI If n IIIII II' " lul n� �I un ul ------L ----------- '======------------ fir= ----z (()) I 2 A13 N===== I I I I rI jl 11 II II II I II II II '-.-------- ---- LII � I +I I I' II II II II II -------------------------------- �' 11 .I II II II II II II I I_ - - - I II I ------------------------------------------------------------------------------ ---------------------------------------------- ------------------------------------------------------------------- -------------- Ir I II I III � ;II + +------------------------------- _________ _________ " " ______________________ ---_e_-_______________________________-'<° III, CLSR2 I II I I II I " ' I II I I II I I op -T-------- I I III , i I I I I II I I I II I III ____R _______8 _==4_____n_____I4_____n_____�4_____ n_____�4_____ n_____ 4_____n_____�"',J-'�_=� c_=i 1=1 l- R====R====-PO=-=== =R-==_ ---- �E---- --- �€ -- �•.w� „ �� n,l II IIII IIII II ��� �� _ __ -r== °y° -__- ==t II III II I II I Iril' MAINIll IL-t I I SALESlu , II W W I II I In of LI I II I In W I I I" I II I --__ T- L, 1 III;; nl µ u-----'? u ---- 44-----n-----�' =-- ---- ---- _`_`_`�___-___ _ __-________-_ --=J ------------- ]IC----------llr�--------_ �l[r------------ iTu I� +------- __-_ �I w�_JL_-_-' - 'i 1 I I I -.-lip- Il--- I I I -____u_____ _____u_____if_____u_____if_____u_____r;f_____u_____ r;;Pl==i =_ '­, - - - - - n - - - 112 I I II I I ------------------u III I I , II I II I II I I I II I I II I II I II I I II I I II I II I I II I I I II I I II I D I I II I II I II I I I II I I II I III , II I -----u-----'�-----u---- �f u �f u f u-----1I I I I I I III n----- 44_____n----- �4_ n____ n_____ 4----- n----- II `TT r-r 'F== eT =_ r _ ___ rr ==_ _ ===1a= _ L3 F1- _ _ _ �EJ = _ _ _- L�FJ - = _ -_a-- IJJ = _ _ _� _ _ ____ ------------ -- ------ -___-- �'I t== '___ ==°I __==b=====� -=-=x-----ram ____ �VF =___may - ---- '-_�� ---=- rl -=--- -----r ---------- :-2I L--1, C---�ll'�-----u ----- if----u-----if- u----- ',f_____u---- _ f----- I4 n 414 n �4 n �4 n 4 n �'1 II I I I I nl III I II ' I I II I II I II I I II I I I II I I I II I I Ill I I I IIt-+---------I I1I11 I i I I T 1'il II I I I I I I ' I I I I I I I I I I I ' I I I I SFr===,IFr-----4 �$____� III III I I l IIII III ----n-----,'4-----n-----,;4-----n----- 4-----n-----� - ----- „ III III II I I I II II III �� III I I II I III 1 I. „ II _________ " I II I III "•I _______ __]]IICC _ ___ ____ JL_---ynn.!_ _!L_-�-.-ei�:_� -i III III f-----f'�-- f I I'll II I ---- --- f of if- if- f----- rrj'1' 14 n 414 n �4 n �4 n III III ' III III , II III---------� `---------�---------� III n III I II' III , W I W I I I I w I I I In I I LI I I W I I I nl I I I LI I I I W I I I Ill I I I I In , lu I I I ul I I I11 I I I11 I I I I I I I Ill .I; III (IIII I�---------------------------+- i' I----------------------------------------- I II I I II ' I III II `` I ,I,I II ', 11 p,I II II;, II I II I LL_____________________________________________LII � III I I LL 11 r �� � I ====================== --======== C- -------- ---- --- --- --- -- -- - _-- ----'--- --------------------T------------------------------------------------------------------------ l.. ___—____—____—____—____—____—____—____—____r _—-6______ ______ Tyr- f , II II II . , II I II II L--J II II II II II II II II II II PARTIAL MISC . FIXTURING PLAN oR� 9 10 11 3/16" = F-0" "'-0" PLASTIC COVER ►VER BOLLARD, ROVIDED BY ►WNER INSTALLED ;Y CONTRACTOR BC4 ""'^"^^ ^"SES, RE: DETAILS -iEET ANCHOR CASES, RE: DETAILS 3 & 4 THIS SHEET 1"xV SELF LEVELING SEALANT TO MATCH CONCRETE HOLD NON -SHRINK GROUT DOWN V g \ 6" CORE DRILL �I I PIPE BOLLARD 1 3/4" = 1'-0" L3x3xl/4"x3" 7/16" O HOLE FACE OF CASE (3) #12 SELF -TAPPING SCREWS (1) 3/8" HILTI KWIK BOLT TZ EXPANSION BOLT W/ 3 1/16" MIN. EMBED 'ONC. SHALL BE EVEL & FLUSH W/ 'OP OF BOLLARD. 'ONC. SHALL HAVE A MOOTH FINISH DIA. SCHEDULE 40 ,TEEL PIPE FILLED J/ CONC., RE: A13 �) CONC. SLAB CASE ANCHORAGE 3" = 1'-0" CASE END OF FRAMIT BE FLU END OF END PA WOOD SHEATI ON CAS FLUSH FINISH PARTITION WALL 1 " = 1'-0" CLOSURE PANEL, RE: A13.7-10 FRP OVER 1/2" WOOD SHEATHING LINE OF REFRIGERATED CASE 600S 162 FRAMED WALL. T.O. FRAMING SHALL MATCH (E) WALL HEIGHT LINE OF (E) WALL BACK OF CASE (2) ANCHOR LOCATIONS AS SHOWN, RE: A13-3 CASE ANCHORAGE PLAN 1/2" = 1'-0" REVISIONS ARCH. PROJECT NO. 23043 DRAWN CHECKED BTH SUBNUTTAL DATES 09/29/2023 OTB DATE �o 0 zw� V yyyy �Oaa U60.Q© V � 0 2 a�r�a�77o�zo w 3wQ ci V ID5vGo�w d C rnF ¢�GU� 0 fXr�a�� e b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.258.6150 www.bhittsarch.com 10562 REGISTERED ARCHITECT BYRON T HILLS STATE OF WASHINGTON 09/29/2023 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT N 0 oC LL� O T � u O O u O N W SHEET TITLE PARTIAL MISC. FIXTURING PLAN & DETAILS SHEET A13 6"x4"0/8" ANGLE CART STOP, NOTCH 4" LEG AROUND PALLET RACKING BASE PLATE ATTACH M HEAD TEK @ 12" O.C. LINE OF 0 END PANE: FURTHEST PROJECTION POINT OF CASE PAINT BENJAMIN MOORE COLOR'GALVESTON GRAY' 6"x4"0/8" ANGLE CART STOP. SET ANGLE W/ 5/8" O EXPANSION ANCHORS W/ A MIN. 2 1/2" EMBED & MAX. HOLE DEPTH OF 3 1/4", RE: A13.7-2 STANDARD ANGLE CART STOP 1 1/2" — 1'-0" COLUMN OF PALLET RACKING PALLET RACK COLUMN TO COLUMN MINUS 100 /2" 1/2" EQ EQ EQ 1/2' 1/: 1 A13.7 A 1 5/8" O EXPANSION ANCHORS W/ A MIN. 2 1/2" EMBED. MAX. HOLE DEPTH 3 1/4" CASE CORNER BOLLARDS, RE: A13 3" NOTCH ANGLE @ FLOOR SINKS AS ANGLE CART 6"x4"x3/8" ANGLE OCCURS, RE: A13.7-12 CART STOP 1 STOP 2 1/2" 1/2" A13.7 5/8" O EXPANSION ANCHORS W/ A MIN. 2 1/2" EMBED & MAX. HOLE DEPTH OF 3 1/4" CASE STANDARD ANGLE CART STOP 1/2" = 1'-0" m PALLET RACKING COLUMN W/ GUARD & BASE PLATE X14, O PALLET RACKING & CART STOP 3" = 1'-0" LINE OF CASE FURTHEST PROJECTION DASHED LINE IS CASE END PANEL BEYOND LINE OF PALLET RACKING 3 I 13.7 COLUMN GUARD I TYP. I 6" x 4" x 3/8" ANGLE CART STOP. SET ANGLE W/ 5/8" DIA. EXPANSION ANCHORS W/ A MIN. 2 1/2" EMBED & 100'-0" MAX. HOLE DEPTH OF 3 1/4", RE: Al3.7-4 F.F. d ° d PAINT BENJAMIN MOORE d e A • °d . ° .. - _ - d a - COLOR'GALVESTON GRAY' OUTSIDE FACE OF PALLET INSIDE FACE OF ANGLE RACKING COLUMN 1/4" ANGLE CART STOP ELEVATION @ CASE UNDER PALLET RACKING 1/2" — 1'-0" 3'- 10 3/4" V.I.F. 2x2x 1 /8 ANGLE TYP. #10 X 3/4" SELF DRILLING SCREWS, (4) PER CONNECTION ATTACH TO TOP OF PARTITION WALL THROUGH PLYWOOD FURRING W/ #10 SELF DRILLING SCREWS 3/4" PLYWOOD FURRING, V.I.F. PLASTIC BAG HOLDER FRAME 1 1 /2" = 1'-0" PLAN 20 GA. GALV. CLOSURE. EXTEND FROM FINISHED FLOOR TO T.O. WALL. SET BOTH LEGS OF CLOSURE IN A BED OF SEALANT. ATTACH W/ # 10 PAN HEAD TEK SCREWS @ 12" O.C. PARTITION WALL @ CASE CLOSURE CASE TO WALL 1 1/2" F-0" ANGLE CART STOP 1 1/2" = P-0" CASE UNDER PALLET RACKING 2x2xl/8 ANGLE BRACKET. ATTACH TO TOP OF PARTITION WALL THROUGH PLYWOOD FURRING W/ (2) #10 SELF DRILLING SCREWS 3/4" SELF TAPPING SCREWS (4) PER CONNECTION AREA 2x2xl/8 ANGLE, TYP. 3/4" LONG #10 SELF DRILLING SCREWS (4) PER CONNECTION. SCREWS INSTALLED FROM THE INSIDE. GRIND FACE SMOOTH TO ALLOW FRAME TO FLUSH W/ BACK OF CASE FASCIA CONTINUOUS V WIDE SELF ADHESIVE (GRAY) VELCRO STRIP. INSTALL HOOK SIDE OF VELCRO CASE METAL FASCIA FURNISHED BY OWNER INSTALLED BY CONTRACTOR CASE METAL FASCIA AS OCCURS, ALIGN W/ OUTSIDE FACE OF LIGHTING CANOPY LINE OF CASE BAG HOLDER FRAME ISOMETRIC BAG HOLDER SUPPORT FRAME @ PRODUCE CASES OPEN M/D CASE a FRONT SIGN SUPPORT , CASE METAL FASCIA 1 1/2" F-0" LINE OF METAL FASCIA FIXTURING & EQUIPMENT SCHEDULE AS400 FURNISHED BY / DETAIL / MARK # DESCRIPTION QTY. NOTES INSTALLED BY REFERENCE MAIN SALES BC4 5911 41/2" RED BOLLARD 2 INSTALL OVER STEEL OWNER / CONTR. A13-1 COVER BOLLARD PER MFR. =Oak_ jlk_ RECOMMENDATIONS CCS1 ANGLE CART STOP @ CASE 1 CONTR. / CONTR. A13.7-1 CCS2 ANGLE CART STOP @ CASE 1 CONTR. / CONTR. A13.7-4 UNDER PALLET RACKING CLSRI CASE CLOSURE 1 1 CONTR. / CONTR. A13.7-10 CLSR2 CASE CLOSURE 2 1 CONTR. / CONTR. A13.7-9 PBH2 7668 PLASTIC BAG HOLDER (4") 1 OWNER / CONTR. A13 & A13.7-6 SGNSP-1 SIGN SUPPORT NO. 1 1 CONTR. / CONTR. A13 & A13.7-11 0 0 0 0 0 0 0 0 MFR. CASE FASCIA @ PRODUCE CASE. OWNER FURNISHED & CONTRACTOR INSTALLED. INSTALL PER MFR. RECOMMENDATIONS PLASTIC BAG HOLDER FRAME, RE: A13.7-7 & A13.7-8 1'-0" 0 0 0 0 1'-6" (VERIFY) LINE OF CASE PLASTIC BAG HOLDER. ATTACH THUR FASCIA W/ (4) #10 SELF DRILLING SCREWS INTO ANGLE SUPPORT. SET AS LOW AS POSSIBLE LINE OF CASE END PANELS - 0 0 V PLYWOOD (3'-0" L x F-0" W), GLUE & SCREW TO TOP OF CASE, CENTER LENGTH OF PLYWOOD UNDER ANGLE FRAME PLASTIC BAG HOLDER 1 1/2" = P-0" ATTACH W/ # 10 PAN HEAD TEK SCREWS @ 12" O.C. 20 GA. GALV. CLOSURE W/ ATTACH W/ # 10 PAN HEMMED EDGE FROM 1 HEAD TEK SCREWS BOTTOM OF END PANEL TO @ 12" O.C. TOP OF CASE. SET IN A BED OFSEALANT PLAN CLOSURE CASE TO CASE 1 1/2" = 1'-0" 6N4"x3/8" ANGLE CART STOP EASE ALL EXPOSED EDGES NOTCH , FLOOR SINK REVISIONS ARCH. PROJECT NO. 23043 DRAWN RB CHECKED BTH SUBMUTAL DATES 09/29/2023 OTB DATE �o 0 zw� W¢0� �8­ ZOO as U yyyy 60. Q© Fob - Ni VypA02U 2 a�r�a�77o�zo 3wQ ci V d �5w (7(7--����[v++Go�w. � H C P - w F��r ¢� 50 E WUN! M.Hd a� 0 r W c� V� e b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p208.2586150 ww w.bhiIIsarch.c om 10562 REGISTERED ARCHITECT v:E!E SHINGTON 09/29/2023 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT N C� OC O � O 0 ~ � H N W SHEET TITLE FIXTURE EQUIPMENT SCHEDULE & DETAILS SHEET A13*7 10 LL — — — — — —i IILL --A Lrr ---- +—+� L L --- + ------------------�----------------- f-+ - _`� FT--I +--_-_`---------�------------fll F—+ _+ 11 __ ___-- 1 _ — (E 4" GCO - _ T-- - _ ) - _ _- — - III II I TT ------- - '---- - ------------- -I --____ ------- 'I r- ,I------- --- - - - - -- -+ +--------- - - - - -- ---- -- ------------- - ->----------- -- - M M M > - E4"CWV- -E4"CWV 5 — E 3n VTR I rl, E 3LL VBF I CD P O ______ 92 A.F.F. `--- IIµ ------- III _T _ _--t - - - i I - -- - - - - - - - - - TI II"� ==p====p=='q rr � =1k= = k=- � a9i i 1 '�II II _- _- - ir ------ (E)FILTERED w, -- - - - - -- WATER U " -- - , I DISPENSER W I; 1 - (E)CD AT I IIII TRUSS SPACE I DFLOOR (E)CD TO (E) SINK' r------------ --- ------------- 1;, a =� _--====�====�====�===L----� ----------------------------------------J " C --- -- - ---------- --T- -T- -- -- -------------- PARTIAL PLUMBING WASTE AND VENT DEMOLITION PLAN 3/32" = F-0" 7t M M N O N N 0C 9 10 (E)1 1/2" CW "(E)1LL HW 1 (TYP.) (E)1" HWCO --� r,: (E)RO' (IN CASES) 1 W - IF �I I _ — .. (E)RO ° ___-_ _ __ _ ___-_ __ ==_ _====___ ___- ____ - =1====- _- -� ' ----- T_ T ______ �, IT : - �, 1 'I _� _ �_ �____ III --- (E)1/2" CW-- 2 ------}------------- -�---------------- I� - �' I I I 441 _417I I � I ' r _ ram_ �- ___ ______-___==-= -= =- -- =- 17 IF II „+ = �--n`-1�--n--1�--n--1�--n-- I--n ^ I I I ifs 1 (TYP.) D— — — — — — — — — — — - III I II TYP.) ( II I _ (IN CASES) TYP. U ------------------I IIII 1 L4 ^I r - ----=--= ==�==-===---======JJj W Ill JI (E)FILTERED WATER DISPENSER _L_ _L_ _L_ _L_ ------�'i' - 1 Y O (TP.) W 1 (E)HOSE 'III 1 BIBB — _ _ — y O I (E)3/4" CW �E)3/4 HW- — — � � I; I'I (E)HOSE BIBB r- - -- -1i _ mil — - - - - - -_-� y PARTIAL DOMESTIC WATER DEMOLITION PLAN °��� 3/32" = 1'-0" GENERAL NOTES 1 CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED FROM OWNER -FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY ACTUAL OWNER -FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED PLUMBING FIXTURES. 2 CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY, DOMESTIC, AND GAS LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. 3 THE INTENTION OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, AND EQUIPMENT NECESSARY, OR REASONABLY INFERABLE AS BEING, FOR FURNISHING, INSTALLTION AND TESTING, COMPLETE AND READY FOR SAFE OPERATION OF THE SYSTEMS DESCRIBED HEREIN. 4 COORDINATE LOCATION OF VENTS THROUGH ROOF TO MAINTAIN 10'-0" CLEARANCE FROM OUTSIDE AIR INTAKES. EACH VENT EXTENSION THROUGH A ROOF SHALL BE AT LEAST 3" IN DIAMETER & TERMINATE NOT LESS THAN 12" ABOVE THE ROOF OR AS REQUIRED BY THE ADMINISTRATIVE AUTHORITY. RE: A7. 5 CONTRACTORS SHALL IDENTIFY ALL SERVICEABLE ITEMS, (CLEANOUT COILS, ETC.) SO THAT THE CEILING SUBCONTRACTOR MAY KNOW WHERE TO INSTALL ACCESS -TYPE PANELS SHOULD A LIFT -UP TYPE CEILING NOT BE INSTALLED. THIS CONTRACTOR SHALL PROVIDE ACCESS PANELS FOR HIS WORK UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. 6 ALL PENETRATIONS MADE THROUGH RATED ASSEMBLIES TO ACCOMODATE WORK OF THIS SECTION, MUST BE SEALED TO MAINTAIN THE RATING OF SUCH ASSEMBLY BY A U.L. RECOGNIZED SEALING METHOD. 7 SLOPE ALL SEWERS BELOW GRADE AS SHOWN ON THIS SET OF PLANS. ALL OTHER PIPING INSIDE BUILDING OR ABOVE GRADE SHALL BE SLOPED PER THE REQUIREMENTS OF THE PLUMBING CODE AND AMENDMENTS ADOPTED BY THE LOCAL AHJ. COORDINATE PIPING BELOW GRADE OUTSIDE BUILDING WITH MASTER UTILITY PLAN AND SITE DRAWINGS. 8 FLOOR SINKS BELOW REFRIGERATED CASE TO BE HALF -EXPOSED. COORDINATE LOCATION WITH REFRIGERATION CONTRACTOR. RE: RI. 9 PLUMBING CONTRACTOR SHALL HIRE A SURVEYOR TO PLOT POINTS FOR ALL NEW FLOOR SINKS, NEW FLOOR DRAINS AND NEW TRENCH DRAINS TO ACCURATELY LOCATE DRAINS AND SINKS AND TO CONFIRM FINISH HEIGHTS OF THE TOP OF ALL SURFACES. 10 SEAL BETWEEN WALLS & PLUMBING FIXTURES PER REQUIREMENTS OF THE HEALTH DISTRICT AND PLUMBING CODE. I I ROUTE PIPING OVER MAIN SALES AND OTHER AREAS WITHIN TRUSS SPACE WHENEVER POSSIBLE. 12 REMOVE ALL EXPOSED UNUSED WASTE AND VENT PIPING. 13 CONTRACTOR SHALL SAWCUT EXISTING CONCRETE SLAB FLOOR AS REQUIRED FOR INSTALLATION OF NEW WASTE AND VENT PIPING. 14 THE POINT OF DISCONNECTION REMAINING IN A PIPING SYSTEM AFTER PIPING HAS BEEN REMOVED SHALL BE PERMANENTLY CAPPED AIR AND WATER TIGHT. 15 COORDINATE PIPING WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS. 16 CONTRACTOR SHALL RETAIN AND PROTECT ALL EXISTING FIXTURES EQUIPMENT, FLOOR SINKS, FLOOR DRAINS, TRENCH DRAINS, AND ALL ASSOCIATED PIPING NOT SPECIFICALLY SHOWN TO BE REMOVED OR RELOCATED ON THIS SET OF PLANS. KEYED NOTES 1 RETAIN AND PROTECT. RE: GENERAL NOTE 16, THIS SHEET. 2 CASE TO BE REPLACED. NO PLUMBING DEMOLITION WORK REQUIRED. REVISIONS ARCH. PROJECT NO. 23043 DRAWN JMC CHECKED RWD SUBMITTAL DATES OTB DATE 5o a o°H 0 0 Q0 m C7 _ O CO 7 N a� Woo aoz �a�o ° ° _ W = _ I 9 a no ZAIW _5Heo nEaU"l W!ismm 4 3 NZ W 00 C P'L W N N 0 U d a� O ch��Pc �P b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.2586150 www.bhiIIsarch.com �O OF WA S -O Q 41741 �<C/ /oNA� 09/ 18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT � O O 0C h--I—II O � � � 00 O1� N W SHEET TITLE PARTIAL PLUMBING DEMOLITION PLANS SHEET (E)FILTERED WATER DISPENSER (D (E)CD AT TRUSSSPAC O (E)CD TO (E) FLOOR SINK 10 r T I + F--------- T---------T-------- T----------I r, ' -Y —--------------- ----- 11 I I I I i 6� M M S ---- -(E)4"CWV—� -� L F —+ F—+ F L_T--- F—+ - === F—+ I 0�0�0 /—(E)4" GCO ______=====1__________________ CD rr====_ ; = = � M M — — — — —E4"CWV_ E R 3 VT ;II (E)3"VBF- -J — —�— =-n==3 A__ ___=___== (E)3 WCO 7 7__= =a:g A „ 92" A.F.F. `---I' -___ o o IH�=- ; I. I w,ll ;III _ II; II I; I - I ` 2D --�— — — — — — — — — I I ' ;IIII; IIII == = = == a = == = = == III nyn n KwL� IIII I�I ____�__ _ == I111�I�I IIII III it I ---------_- ° C �I i I ------------ ------------- ------------------- I II ------------- ------------------ ------------- ---------------- PARTIAL PLUMBING WASTE AND VENT PLAN 3/32" = 1'-0" 7t M M N O N N DO GENERAL NOTES 1 CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED FROM OWNER -FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY ACTUAL OWNER -FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED PLUMBING FIXTURES. 2 CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY, DOMESTIC, AND GAS LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. 3 THE INTENTION OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, AND EQUIPMENT NECESSARY, OR REASONABLY INFERABLE AS BEING, FOR FURNISHING, INSTALLTION AND TESTING, COMPLETE AND READY FOR SAFE OPERATION OF THE SYSTEMS DESCRIBED HEREIN. 4 COORDINATE LOCATION OF VENTS THROUGH ROOF TO MAINTAIN 10'-0" CLEARANCE FROM OUTSIDE AIR INTAKES. EACH VENT EXTENSION THROUGH A ROOF SHALL BE AT LEAST 3" IN DIAMETER & TERMINATE NOT LESS THAN 12" ABOVE THE ROOF OR AS REQUIRED BY THE ADMINISTRATIVE AUTHORITY. RE: A7. 5 CONTRACTORS SHALL IDENTIFY ALL SERVICEABLE ITEMS, (CLEANOUT COILS, ETC.) SO THAT THE CEILING SUBCONTRACTOR MAY KNOW WHERE TO INSTALL ACCESS -TYPE PANELS SHOULD A LIFT -UP TYPE CEILING NOT BE INSTALLED. THIS CONTRACTOR SHALL PROVIDE ACCESS PANELS FOR HIS WORK UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. 6 ALL PENETRATIONS MADE THROUGH RATED ASSEMBLIES TO ACCOMODATE WORK OF THIS SECTION, MUST BE SEALED TO MAINTAIN THE RATING OF SUCH ASSEMBLY BY A U.L. RECOGNIZED SEALING METHOD. 7 SLOPE ALL SEWERS BELOW GRADE AS SHOWN ON THIS SET OF PLANS. ALL OTHER PIPING INSIDE BUILDING OR ABOVE GRADE SHALL BE SLOPED PER THE REQUIREMENTS OF THE PLUMBING CODE AND AMENDMENTS ADOPTED BY THE LOCAL AHJ. COORDINATE PIPING BELOW GRADE OUTSIDE BUILDING WITH MASTER UTILITY PLAN AND SITE DRAWINGS. 8 FLOOR SINKS BELOW REFRIGERATED CASE TO BE HALF -EXPOSED. COORDINATE LOCATION WITH REFRIGERATION CONTRACTOR. RE: Rl. 9 PLUMBING CONTRACTOR SHALL HIRE A SURVEYOR TO PLOT POINTS FOR ALL NEW FLOOR SINKS, NEW FLOOR DRAINS AND NEW TRENCH DRAINS TO ACCURATELY LOCATE DRAINS AND SINKS AND TO CONFIRM FINISH HEIGHTS OF THE TOP OF ALL SURFACES. 10 SEAL BETWEEN WALLS & PLUMBING FIXTURES PER REQUIREMENTS OF THE HEALTH DISTRICT AND PLUMBING CODE. 11 ROUTE PIPING OVER MAIN SALES AND OTHER AREAS WITHIN TRUSS SPACE WHENEVER POSSIBLE. 12 REMOVE ALL EXPOSED UNUSED WASTE AND VENT PIPING. 13 CONTRACTOR SHALL SAWCUT EXISTING CONCRETE SLAB FLOOR AS REQUIRED FOR INSTALLATION OF NEW WASTE AND VENT PIPING. 14 THE POINT OF DISCONNECTION REMAINING IN A PIPING SYSTEM AFTER PIPING HAS BEEN REMOVED SHALL BE PERMANENTLY CAPPED AIR AND WATER TIGHT. 15 COORDINATE PIPING WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS. 16 CONTRACTOR SHALL RETAIN AND PROTECT ALL EXISTING FIXTURES, EQUIPMENT, FLOOR SINKS, FLOOR DRAINS, TRENCH DRAINS, AND ALL ASSOCIATED PIPING NOT SPECIFICALLY SHOWN TO BE REMOVED OR RELOCATED ON THIS SET OF PLANS. KEYED NOTES I RETAIN AND PROTECT. RE: GENERAL NOTE 16, THIS SHEET. 2 NEW CASE. NO PLUMBING WORK REQUIRED. 3 CONNECT TO EXISTING WASTE BELOW FLOOR AND EXTEND NEW WASTE TO NEW FLOOR SINK. PATCH FLOOR. RE: ARCH. REVISIONS ARCH. PROJECT NO. 23043 DRAWN JMC CHECKED RWD SUBMITTAL DATES OTB DATE �o a o°H 0 0 z�a0.o ¢o �Qz� EN o m rr r cG���7 W Fpr.GG. u1� aZpZa /Zyy li 'n ._ N W .9] O W ��� a pyqyHeoo Z Al E d �Z�+a I EIJ o6 aC�+ 3 N Ca��O�Op W y 3 O � RIM" N H 0 U d a� Pc �P b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.2586150 www.bhiIIsarch.com C O OF WA SJ 41741 �<C/ oNA� 09/18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT N �0C o CN h--I—II Q � 00 � o � N W 1 SHEET TITLE PARTIAL PLUMBING WASTE AND VENT PLAN SHEET 9 t (E)1 1/2" CW----------- ,(E)111 HW 1 (TYP.) (E)111 HWC� (IN CASES)() 1 W-(E)RO' -fi ! (E)RO ° ------ ------- ----------_-----------------=1==1=====____SIT-====_� di (E)1/2 CW---------------- ---1-7'---�----� 1 �a OI I I LlE - - - - - - - - T - - - ------ - - — I I I ° H 12 T - - = a -- W 1 (TYP.) I , D— — — — — — — — — — — _ 2 JiL�� 1 7� (INCASES) U II�� (TYP.)I , ____________ _________________J' W,�� W _ J (E)FILTERED I _ ------- _=-______ WATER - --- --- - a'iI DISPENSER �, ------u l ,r—` n--�-- - --74-- --iF= - - - - - - 1 ii , imi Ln - - i - - i - - i - - - - uy loll , ii i i�i � ii� imi Y� II` II II II 'II' �J loll iii - - wU 12 (TYP.) W " I CD 1 _ (E)HOSE O BIBB — — — — —(E)3/4 HW- — gg�,, (E)HOSE (E)3/4" CW- — — — BIBB _ __-_________________ IG - = C_- _--_--- ---- -- _ _c_ - - - ----------------------------------- _ PARTIAL DOMESTIC WATER PLAN 3/32" = F-0" GENERAL NOTES 1 CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED FROM OWNER -FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY ACTUAL OWNER -FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED PLUMBING FIXTURES. 2 CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY, DOMESTIC, AND GAS LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. 3 THE INTENTION OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, AND EQUIPMENT NECESSARY, OR REASONABLY INFERABLE AS BEING, FOR FURNISHING, INSTALLTION AND TESTING, COMPLETE AND READY FOR SAFE OPERATION OF THE SYSTEMS DESCRIBED HEREIN. 4 COORDINATE LOCATION OF VENTS THROUGH ROOF TO MAINTAIN 10'-0" CLEARANCE FROM OUTSIDE AIR INTAKES. EACH VENT EXTENSION THROUGH A ROOF SHALL BE AT LEAST 3" IN DIAMETER & TERMINATE NOT LESS THAN 12" ABOVE THE ROOF OR AS REQUIRED BY THE ADMINISTRATIVE AUTHORITY. RE: A7. 5 CONTRACTORS SHALL IDENTIFY ALL SERVICEABLE ITEMS, (CLEANOUT COILS, ETC.) SO THAT THE CEILING SUBCONTRACTOR MAY KNOW WHERE TO INSTALL ACCESS -TYPE PANELS SHOULD A LIFT -UP TYPE CEILING NOT BE INSTALLED. THIS CONTRACTOR SHALL PROVIDE ACCESS PANELS FOR HIS WORK UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. 6 ALL PENETRATIONS MADE THROUGH RATED ASSEMBLIES TO ACCOMODATE WORK OF THIS SECTION, MUST BE SEALED TO MAINTAIN THE RATING OF SUCH ASSEMBLY BY A U.L. RECOGNIZED SEALING METHOD. 7 SLOPE ALL SEWERS BELOW GRADE AS SHOWN ON THIS SET OF PLANS. ALL OTHER PIPING INSIDE BUILDING OR ABOVE GRADE SHALL BE SLOPED PER THE REQUIREMENTS OF THE PLUMBING CODE AND AMENDMENTS ADOPTED BY THE LOCAL AHJ. COORDINATE PIPING BELOW GRADE OUTSIDE BUILDING WITH MASTER UTILITY PLAN AND SITE DRAWINGS. 8 FLOOR SINKS BELOW REFRIGERATED CASE TO BE HALF -EXPOSED. COORDINATE LOCATION WITH REFRIGERATION CONTRACTOR. RE: RL 9 PLUMBING CONTRACTOR SHALL HIRE A SURVEYOR TO PLOT POINTS FOR ALL NEW FLOOR SINKS, NEW FLOOR DRAINS AND NEW TRENCH DRAINS TO ACCURATELY LOCATE DRAINS AND SINKS AND TO CONFIRM FINISH HEIGHTS OF THE TOP OF ALL SURFACES. 10 SEAL BETWEEN WALLS & PLUMBING FIXTURES PER REQUIREMENTS OF THE HEALTH DISTRICT AND PLUMBING CODE. 11 ROUTE PIPING OVER MAIN SALES AND OTHER AREAS WITHIN TRUSS SPACE WHENEVER POSSIBLE. 12 REMOVE ALL EXPOSED UNUSED WASTE AND VENT PIPING. 13 CONTRACTOR SHALL SAWCUT EXISTING CONCRETE SLAB FLOOR AS REQUIRED FOR INSTALLATION OF NEW WASTE AND VENT PIPING. 14 THE POINT OF DISCONNECTION REMAINING IN A PIPING SYSTEM AFTER PIPING HAS BEEN REMOVED SHALL BE PERMANENTLY CAPPED AIR AND WATER TIGHT. 15 COORDINATE PIPING WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS. 16 CONTRACTOR SHALL RETAIN AND PROTECT ALL EXISTING FIXTURES, EQUIPMENT, FLOOR SINKS, FLOOR DRAINS, TRENCH DRAINS, AND ALL ASSOCIATED PIPING NOT SPECIFICALLY SHOWN TO BE REMOVED OR RELOCATED ON THIS SET OF PLANS. KEYED NOTES 1 RETAIN AND PROTECT. RE: GENERAL NOTE 16, THIS SHEET. 2 NEW CASE. NO PLUMBING WORK REQUIRED. REVISIONS ARCH. PROJECT NO. 23043 DRAWN Author CHECKED Checker SUBMITTAL DATES OTB DATE 5o a o°H ��Ft✓�� 0 0 o�ao 60m� o m Z In aoz o W = Emd W-ID���a pyqy `��wjao Z o E d �Z.+a 5 �p6 fj[.vRlKE H 0 Z '. 3 N I Q� 6 5, � 0 ya [-. a = W W 3 N V ��u�dZa N O 0 U d a� e b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.2586150 www.bhiIIsarch.com C O OF WA -o Q 41741 �<C/ hEGISTER� ass/ONA � E 09/ 18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT O V 0C r O � � 00 N W SHEET TITLE PARTIAL DOMESTIC WATER PLAN SHEET PLUMBING LEGEND ABBREV. DESCRIPTION ABBREV. DESCRIPTION SPOINT OF NEW CONNECTION __+�, HOSE BMB S :0 PIPE DOWN --- 1 � 1 SHUT-OFF VALVE PIPE UP t- - - - - - - -t PLUMBING DEMOLITION NEW VENT ABOVE GRADE NEW COLD WATER - - - - - - - NEW WASTE BELOW GRADE NEW HOT WATER EXISTING VENT ABOVE GRADE - - - - - - -� NEW CIRCULATING HOT WATER EXISTING WASTE BELOW GRADE t EXISTING COLD WATER O KEYNOTE CALLOUT EXISTING HOT WATER e DETAIL CALLOUT _ EXISTING CIRCULATING HOT WATER UNIT NAME e ( GAS SHUT-OFF VALVE UNIT NUMBER - - NEW FLOOR SINK 3 CAP - - - - - - NEW FLOOR DRAIN - - � - - - - EXISTING FLOOR SINK - - - - - NEW FLOOR CLEANOUT EXISTING FLOOR DRAIN - - /0 //0- - - NEW WALL CLEANOUT EXISTING FLOOR CLEANOUT O EXISTING VTR - - Z/�_) x0_ - - EXISTING WALL CLEANOUT ABBREV. DESCRIPTION BFF BELOW FINISHED FLOOR OD OVERFLOW DRAIN LINE BP BACKFLOW PROTECTED COLD WATER (R) RELOCATED CW DOMESTIC COLD WATER RD ROOF DRAIN LINE CWV COMBINATION WASTE AND VENT SPEC SPECIFICATION OR SPECIFIED (E) EXISTING FCO FLOOR CLEAN OUT SS SANITARY SEWER FD FLOOR DRAIN TYP TYPICAL FS FLOOR SINK UNO UNLESS NOTED OTHERWISE FW FILTERED WATER V VENT VBF VENT BELOW FLOOR GW GREASE WASTE VTR VENT THROUGH ROOF HW HOT WATER WCO WALL CLEAN OUT HWC HOT WATER RECIRCULATON (N) NEW PLUMBING FIXTURE SCHEDULE PIPING CONNECTIONS FIXTURE MANUFACTURER SSE OWNER CONT. OWNER CONT. NOTES TRAP WASTE VENT CW HW NO. DESCRIPTION & CAT. NO. FURN. FURN INSTALL INSTALL FS-1 FLOOR SINK CASES) SIOUX CHIEF NO EXCEPTIONS P 2„ - _ _ __ X -- X RE: P5-1 AND P5-2. 00 (REFRIGERATED MODEL 860-2P26 A. ALL PLUMBING FIXTURES OR EQUIPMENT UTILIZING AN INDIRECT WASTE CONNECTION TO DRAIN INTO SANITARY SEWER SYSTEM SHALL HAVE AN AIR GAP AS REQUIRED BY THE PLUMBING CODE. PLUMBING FIXTURE NOTES OSCHEDULE 40 GREY PVC FLOOR DRAIN WITH 9" ROUND TOP, NO HUB OUTLET, SCHEDULE 40 GREY PVC HALF GRATE, GREY PVC FLAT SECONDARY STRAINER AND 3" TRAP. FLOOR SINK TO BE INSTALLED FLUSH WITH FINISHED SURFACE. CONTRACTOR TO CUT FLOOR SINK GRATE PER DETAIL P5-2 AND RE -INSTALL BOTH ARC AND GRATE IN FLOOR SINK. J kn M M N O N N 0C REVISIONS ARCH. PROJECT NO. 23043 DRAWN JMC CHECKED RWD SUBMITTAL DATES OTB DATE 10 a o°H 0 0 ENJ aoz W = _ a pyqy `��wjao E d �Z�+a a O W Z aC�+ 3 N I y WOO A •� V O ai�= u�¢ Za ' 3 0 W w N V o N 0 U d a� �h O Pc P b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.2586150 www.bhiIIsarch.com C O OF WAS e Q 41741 �<C/ /oNA� 09/ 18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT N O 0C CN O O O O H� CN h� N W 1 SHEET TITLE PLUMBING SCHEDULE AND LEGEND SHEET REFRIGERATION DISPLAY CASE MIN. 1" HIGH STAINLESS STEEL - AROUND BACK HALF OF FLOOR SINK UNDER CASE. SECURE TO RIM OF FLOOR SINK W/ SILICONE CAULKING 3" BRANCH LINE' 3" P- REFRIGERATION DISPLAY CASE CASE CONDENSATE DRAIN LINE BY REFRIGERATION CONTRACTOR CK PLATE FLOOR SINK HALF EXPOSED IN FRONT OF KICK PLATE FLOOR " TAILPIECE NOT TO EXCEED 24" IN LENGTH 3"x2" NO -HUB REDUCER AT TOP OF P-TRAP REQUIRED FOR FIXTURES ON COMBINATION WASTE AND VENT SYSTEM ONLY. NOTE: IT IS THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO COORDINATE DRAIN LOCATIONS WITH THE REFRIGERATION CONTRACTOR AND REFRIGERATION PLANS TO ENSURE THE FLOOR SINKS ARE HALF EXPOSED WHEN THE CASES ARE INSTALLED. IF CONFLICTS EXIST, CONTACT THE ARCHITECT FOR A RESOLUTION BEFORE PROCEEDING. CASE FLOOR SINK DETAIL NTS J kn M M N O N N 0C 4 3/4" o REMOVE 0 o MIDDLE r1 SEGMENT 0 0 0 0/ SCUT LINE v 'CUT LINE NOTES: 1. DIMENSION SHOWN IS FROM OUTSIDE OF GRATE. 2. GRATES TO BE CUT SHALL BE AT REFRIGERATED CASE FLOOR SINKS ONLY. CASE FLOOR SINK 2 GRATE DETAIL NTS REVISIONS ARCH. PROJECT NO. 23043 DRAWN JMC CHECKED RWD SUBMITTAL DATES OTB DATE 10 a o°H �UU�a o �a 0 Z p�a ON Q 0 m � vi _ O CO 7 fUUV aoz m o .� N Wff E a .WaHeoo Z p� yEREH Og oo06 3ed � ZE N OWOI a ' u�¢ z= W 2 w C" V o N 0 U d a� �h O b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.2586150 www.bhiIIsarch.com C O OF WAS /` e -o Q 41741 �<C/ /oNA� 09/ 18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT N � O 0 oC CN 0 � 00 O ~ C Q N W 1 SHEET TITLE PLUMBING DETAILS SHEET GENERAL NOTES 1. THE INTENT OF THIS PLAN IS TO SHOW AN OVER-ALL SCOPE OF THE DEMOLITION WORK REQUIRED FOR THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE REMOVAL OF UNUSED ELECTRICAL EQUIPMENT WHERE PRACTICAL. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL 9 10 TEMPORARY /CONSTRUCTION LIGHTING AND POWER DURING THE REMODEL AS NECESSARY FOR CONTINUED OPERATION OF ALL STORE FUNCTIONS. 3. 3. ALL DEVICES SHOWN AND ALL ASSOCIATED CONDUIT AND CONDUCTORS ARE TO BE DISCONNECTED AND REMOVED UNLESS OTHERWISE NOTED. 4. 4. WHERE THE REMOVAL OF ANY FIXTURE, DEVICE OR EQUIPMENT 5. RESULTS IN DEMOLITION OF AREAS TO REMAIN, CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING OR REPLACING ANY -+- *_ I''' I f FLOORS, CEILINGS OR WALLS AS NECESSARY TO MATCH == -_ _ _ _ _ ' EXISTING ------ 'F_T }-__Y------ _+- ___________ ____� 1____ ,_ _ _ - 6. SURROUNDINGS OR TO ACCOMMODATE NEW FINISHES DF—}- KEYED NOTES _ _ J---_'T_ I. DROP CORD TO BE DISCONNECTED AND REMOVED. ___________ _ _ _ _ _ _ _ _ _ _ _ '-- CONTRACTOR TO PROTECT AND RETAIN CONDUIT, ___________ +- _7=====111ll—}- CONDUCTORS, AND JUNCTION BOX. ____________+____L_1____+_ ______________________i�'I'' I I LF-20,22 s 7 (E)3/4"C-(E)3#10,1#110G y =_ ___________ _________________________-____---------- _____________====____-__=_ y lk ------------ - ----------- -r----------- ----------------------- _—___ DE— — - — - — - — - — - — - — ------ -,--T -- -_77 II { __ {1__ 11 _____ I�L W✓_i III =_=- - r� � �r r - r -El — — r k-F-----�I r ri� II {_ I __ .=_e_-- ==_s_-=_ _ __ e= _ I _ez e_e �4 y4 ------- 44I I III .rt __7C__Trt__7C__Trt__7t__Trt__- f__ — .,1� _ - F+ III F III III �4 y4 y4 dy 4 - - - {, I I I II I II I I � F-1_ ----------= - - = PANEL LF �_ _I.. ________________________ , E----------------- ----- --- — --- — ------------- __ — — t=_= __: — — — — — __(�) 9 10 PARTIAL ELECTRICAL DEMO PLAN ORT REVISIONS ARCH. PROJECT NO. 23043 DRAWN BH CHECKED WBC SUBMITTAL DATES OTB DATE 'o 0 aE,F9� a p Udgu SZ© d 5 W F y apz 7 N O W oa��yWo� UN[7K a� v Z ❑ ''�^^ � � N ED 00 WDA Da' V d00 • v I c O p�p ❑vd�C7m�5 � W N 3 N = N 02 0 U d 0 a�• /"'[Pc"v �P b,hills architecture, PC 3156 south bown way boise Idaho 1 83706 p. 2 0 8. 2 5 8. 6 1 5 0 www,bhillsarch.com RFGis FSS�ONAL ENG\ 09/18/23 ,EECEIVED M Oct 02 2023 CITY OF EDMON�C EVELOPMENT SE E DEPARTMENT MO O W W O O O O N W SHEET TITLE PARTIAL ELECTRICAL DEMO PLAN SHEET 9 10 , -----------IT---- L—J----'+'------------'T------------ J� F--+--1=_________ �____- �I 11------------------------I � f-----------i^*j = =LJ== _ - ------ ,r------Y--- 1 -+-1 III +--------- -_ ===1 ___________ ---------- - _ _ � _ _ _ _�__ _ _ —+- -_--_i ! +---------- �� ------ -iti-- -L-1- -JL- _Iti__ ---- _Ii�n TJ I _=====(N)�/4"C WITH (N)2# 12-LF-34 FANS (N)2#12-LF-36 LIGHTS (N)1 # 12 GND - 2 Y - (N-)/4"C WITH (N)M4 CONTROLS -T------ LL=======u====-------==-===u=====-=Y=======y=======u -y--________ -- �I --------------------------- --------------------------------------------------------------- ' JJ F_=--__ __________________ __________________________ 1 -- - _ O� � �-� III —— — — — — E r -rm rr { _= { ----- „rl4 �4 44 - ���.=mot=�� i IFT=====i Ali -------i--- -- ---- I _ ="SIT---^---TAT---u---Y�I P II NIP p I ,, II p II (N)LF-38,40 P II r II (N)3/4"C - (N)3#8,1#10G(DD P "4— 1' II �' II '' II 1� _=� __=__ - ==� __ 6 I 5 __ ___Trt__ T ___ __T __ __ T. LA: I �I I I I {'{------- {'f--- -0U--- {`{'' ------ ---------- I h I Tb I II II I I --'--------_ ---------------- _____ ___________ ------- - - - - - - - - - - i I'll 4---4 �4 � 14 Tt, I0i �14-- ••__ I i C.4 I I ! I Ili iIli I I I II i iIli ______________=--^`'__-_=_==___- __________=�, PANEL LF --------------- cry II n idi uii n idi n idi IIII �lilu phi i' I I _______ r_� l� — LL---------------------- C=-----------=LL---=-----_------_--------r---_-----_----- _----------- _----_- ----=J C IFT -------------------------------------------- `� �mi, r----- "-------------------------------- 9 10 PARTIAL ELECTRICAL REFRIGERATION POWER PLAN 1/8" 11-011 GENERAL NOTES 1. PROVIDE COPPER EQUIPMENT GROUNDING CONDUCTOR, SIZED PER N.E.C. 250, IN ALL CONDUITS WITH CIRCUIT CONDUCTORS. 2. ALL VISIBLE CONDUITS ARE TO BE PAINTED TO MATCH SURROUNDING FINSIHES BY OTHERS. 3. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY ALL CIRCUITRY OF EXISTING EQUIPMENT THAT IS SHOWN INCLUDED IN THE SCOPE IN THESE DOCUMENTS PRIOR TO START OF ONSTRUCTION, AND UPDATE EXISTING PANEL SCHEDULES AS NEEDED. ANY EXISTING CIRCUIT NUMBERS SHOWN ARE BASED OFF ASBUILT INFORMATION, AND MUST BE CONFIRMED. ASBUILT INFORMATION CAN BE SUPPLIED TO CONTRACTOR IF REQUESTED THROUGH RFI. 4. CONTRACTOR TO PROVIDE NEW BREAKERS IN EXISTING PANELS. KEYED NOTES 1. NEW REFRIGERATED CASE HAS 120V EEV DRIVER. FEED DRIVER FROM CASE FAN CIRCUIT WITH 2# 12. 2. REFER TO R4 FOR CONTROL WIRE TERMINATION. FOLLOW POWER CONDUIT ROUTING FROM CASE TO ROOF STRUCTURE. 3. PROVIDE 3/4"C WITH CALIBRATED PULL TAPE TO VOID ABOVE CEILING OR TO BOTTOM OF ROOF STRUCTURE FOR CONTROL WIRING. FOLLOW POWER CONDUIT ROUTING FROM CASE TO ROOF STRUCTURE. 4. PROVIDE AND INSTALL J-BOX MOUNTED AT BOTTOM OF JOIST TO FEED RECEPTACLES BELOW. CONTRACTOR SHALL ROUTE CONDUIT IN CHANNEL BETWEEN PALLET RACKING. ROUTE CONDUIT IN SUCH A MANNER THAT IT WILL NOT BE DAMAGED BY MOVEMENT OF PALLETS/EQUIPMENT. 5. CONTRACTOR TO SURFACE MOUNT JUNCTION BOX ON BACK OF PALLET UPRIGHT JUST BELOW THE LOWEST SHELF OF THE HIGH PALLET STORAGE ABOVE. CONTRACTOR TO VERIFY PLUG TYPE PRIOR TO ELECTRICAL ROUGH IN AND PROVIDE APPROPRIATE RECEPTACLE. ELECTRICAL POWER LEGEND JUNCTION BOX SPECIAL CONNECTION PANEL BOARD REVISIONS ARCH. PROJECT NO. 23043 DRAWN KI) CHECKED JF SUBMITTAL DATES OTB DATE �o 0 d U 5 W F y aoz CN O I W < ri oa yyWo� Z ❑ 2 m N WW ADa' W F h a a d00 ''—^^ I 1..1 a0 v Z w 3 N ¢ c OpV m mg W N 3 N 0 �F a�• �P b,hills architecture, PC 3156 south bown way boise Idaho 1 83706 p. 2 0 8. 2 5 8. 6 1 5 0 www,bhillsarch.com � PN A. WAS c P 7 Z A RF 34 7 E ING 09/18/23 ,EECEIVED M Oct 02 2023 CITY OF EDMON�C ,v----PEVELOPMENT SE E DEPARTMENT O 0C W ` u� I� O O O O r� N W SHEET TITLE PARTIAL ELECTRICAL REFRIGERATION PLAN SHEET PANELBOARD SCHEDULE (EXISTING)PANEL:LF VOLTAGE: 208/120V PHASE: 3 WIRE: 4 AMPERE RATING: 100A SC RATING: 10KAIC MAIN: 100A MAIN BREAKER ENTRY: MOUNTING: SURFACE LOADS: Amps VA PHASE A: 17 2076.88 PHASE B: 18 2184.88 PHASE C: 0 24 TOTAL: 4285.76 LOAD TYPES: 1 = LIGHTING 2 = RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS: LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO AMPS/ POLES LOAD TYPE NOTE LOAD SERVED LOAD (VA) SYS A34 FANS E 15 1 1 A 2 40 2 E REMOTE PANEL 4 SYS A34 AS E 20 1 3 B 4 -- - E --- SYS A34 LIGHTS E 20 1 5 C 6 15 1 E SYS B7, B8, B9 FANS SYS Cl FANS E 20 1 7 A 8 20 1 E SYS B7, B8, B9 LIGHTS SYS C2 FANS E 15 1 9 B 10 20 1 E REC-PRODUCE RECEIVING SYS C2 LIGHTS E 20 1 11 C 12 20 1 E REC-PORTABLE PRESSURE WASHER SYS C3 FANS E 15 1 13 A 14 20 1 E HAND DRYER SYS C3 LIGHTS E 20 1 15 B 16 20 1 E BATTERY CHARGER SYS C4 FANS E 15 1 17 C 18 20 1 E EXISTING SYS C4 LIGHTS E 20 1 19 A 20 25 2 E SPARE SYS C5 FANS E 15 1 21 B 22 -- - E --- SYS C5 LIGHTS E 20 1 23 C 24 20 1 E REC-DROP CORD MAIN SALES SYS C6 FANS E 15 1 25 A 26 20 1 E REC-PRODUCE SYS C6 LIGHTS E 20 1 27 B 28 20 1 E REC-JOIST PRODUCE SYS C7 FANS E 15 1 29 C 30 20 1 E SPARE SYS C7 LIGHTS E 20 1 31 A 32 20 1 E COFFEE VENDING MACHINE SYS C11 FANS E 20 1 33 B 34 20 1 4 R SYS C20 FANS 108 INSECT TRAP/DETEX E 20 1 35 C 36 20 1 1 R SYS C20 LIGHTS 24 BATTERY CHARGER E 20 1 37 A 38 45 2 3 N SELF CONTAINED MERCHANDISER 2077 ROOF OUTLET E 20 1 39 B 40 -- - 3 N -- 2077 UP OUTLET E 20 1 41 C 42 20 1 1 E ISPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 24 VA 210-19 125% 30 VA E - DENOTES EXISTING BREAKER TO REMAIN. RECEPTACLES 0 VA 220-44 10kVA @ 100%, ELSE @ 50% 0 VA N - DENOTES NEW BREAKER REQUIRED. MISC. 4154 VA 220-60 100% 4154 VA R - DENOTES TO REUSE EXISTING BREAKER. MOTOR LARGEST MOT.: 108 108 VA 220-50 100% + LARGEST x 25% 135 VA KITCHEN # OF KIT. UNITS: OVA 220-56 0 VA TOTAL 12 A 12 A REVISIONS ARCH. PROJECT NO. 23043 DRAWN KD CHECKED JF SUBMITTAL DATES OTB DATE uo a xry�°F �o�W�oo O m _ g i�mawzz" �a�"FoPozc ° Z N o � _ a�i W o W¢��� wa��aoWg o W m .� a � wooaw� aoawoo^ � m Z N °' oo c ? oo gza�admoa3^ WO U m o Fx¢^a�x [-W CYC U U L d Z� a�• �P b.hills architecture, PC 3156 south bown way boise Idaho 1 83706 p. 2 0 8. 2 5 8. 6 1 5 0 www.bhiIIsarch.com N A. G P �P AS2 A 7 TERE� �FSS ONA L ENG\ 09/18/23 ,EECEIVED M Oct 02 2023 CITY OF EDMON�C r--.4)EVELOPMENT SE E DEPARTMENT � � O O 0C W O O V r� N W SHEET TITLE ELECTRICAL PANEL SCHEDULES SHEET (DF7 ff) C--� ►E Cm 00 N 00 M N O N N N 00 10 11 I I I I C PARTIAL REFRIGERATION DEMO PLAN 1 /4" = 11-011 rml o o � I 0 0 r7in 0 GENERAL NOTES 1. THE REFRIGERATION CONTRACTOR SHALL INVESTIGATE AND ENSURE COMPLIANCE WITH ALL FEDERAL, STATE, AND LOCAL CODES PRIOR TO INSTALLATION. THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES. 2. UPON COMPLETION OF INSTALLATION, REFRIGERATION CONTRACTOR TO ENSURE ALTERED RACK UNITS ARE PROPERLY CHARGED WITH REFRIGERANT. 3. COMPLY WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS REGARDING REFRIGERANT RECLAIMING, SYSTEM EVACUATION, EQUIPMENT, OIL AND REFRIGERANT DISPOSAL. 4. COMPLETE THE APPROPRIATE WINCO FOODS REFRIGERANT TRACKING FORMS AND PROVIDE DOCUMENTATION THAT ALL OTHER REGULATIONS HAVE BEEN COMPLIED WITH. KEYED NOTES 1. RELOCATE EXISTING MOBILE MERCHANDISER. COORDINATE WITH WINCO PM & STORE MANAGER FOR LOCATION. REVISIONS ARCH. PROJECT NO. 23043 DRAWN DT CHECKED GH SUBMITTAL DATES OTB DATE �o 0 ,Udgu 4°© ED ? ; 4N 0. p [x1 F ZO '°' W O ¢°Z aQKma° Z (U 3 N 3 W �F�°Ama cV j v no 0 �F a� chi 14 ec14 e b.hills architecture, PC 3156 south bown way boise I idaho I 83306 p.208.2586150 www.bhillsarch.com ,QQ` pF WASy�N R1741 FIGISTER�G����'� S/ONAL EN 9/ 18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT N O� O O� 00 W Q r� � 00 O N W SHEET TITLE PARTIAL REFRIGERATION DEMO PLAN SHEET RO 9 10 0 __-T------------------ T------------------ I! .................... c20.01 --------------------------------- - —----------- ---- -1---------------------------- - - - - --------- - - - - -------------- - - - - -------------- - - - - -- ------------------ ------------- —------------- ----------- ------------------------- -------------------------------------------------------------------- -------------------------------------------------------- [0 O a a ----- e a ------------------a----------------- ------------------ ^------------------ '------------------ OP____________�________________ _______________ V------------------tt____________________________________!V_---y a_====______________ # ____________________ _________________ p____ _____ p _ ____ 1'n'____ _____ _____l� _1p r_ ---------_____ __ O H V � I 2 4 -$------------------$------------------�L�---- ---� x --- - a ____________ � —— t �' CT I I c ►E Cm 00 N 00 M N O N N N 00 PARTIAL REFRIGERATION PLAN 1 /4" 1'-011 Ee REFRIGERATION LEGEND SYMBOL DESCRIPTION ® ® TEMPERATURE PROBE NEW FLOOR SINK GENERAL NOTES 1. REFRIGERATION CONTRACTOR TO WIRE AND TERMINATE ALL TEMPERATURE PROBES USING BELDEN 8762, OR EQUIVALENT. WIRING SHOULD BE CAREFULLY ROUTED AWAY FROM POWER LINES OR OTHER HIGH ELECTRICAL NOISE ENVIRONMENTS. 2. TEMPERATURE PROBES FOR NEW CASES SUPPLIED AND INSTALLED BY CASE MANUFACTURER. 3. RE: ARCH PLANS FOR FLOOR SINK DIMENSIONS. 4. ANTISWEAT HEATERS NOT TO BE ENERGIZED UNTIL THE CASES HAVE BEEN REFRIGERATED. KEYED NOTES 1. NEW FLOOR SINK. RUN NEW CASE DRAIN LINE TO THIS LOCATION. RE: P 1. 2. NEW CASE TEMPERATURE PROBE. REFRIGERATION CONTRACTOR TO INSTALL NEW WIRING TO REMOTE PANEL 4 (LOCATED ABOVE CASE C6.02 ON SALES FLOOR). REFRIGERATION CONTRACTOR TO PROGRAM AND PROVE PERFORMANCE OF CASE, CONTROLS, AND ALARMING. RE: R5. REVISIONS ARCH. PROJECT NO. 23043 DRAWN DT CHECKED GH SUBMTTTAL DATES OTB DATE 'o 0 F�� ED Q z ; N a Fo° W s cod W LW Z ❑ . m N _00 66r3c"Om V F��n° Z W 3 N W " �� °Ama v ° �F a� ec e b.hills architecture, PC 3156 south bown way boise I idaho I 83706 p.208.2586150 www.bhillsarch.com H. M ,QQ` pF WASy�N �O.c R1741 FGISTE- FSS/ONAL ENG\ 9/ 18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT • � O O � W V 1 T O V O O N W SHEET TITLE PARTIAL REFRIGERATION PLAN SHEET 9 I D ' _ I =rJ o % itj --------------- --3 r ' r w: ------------------ 1------------------ k-� k. " k•• w.. TuTI `TT' TiT' -t----vn li r-------- 4------------------------ IW----------r----1--------- W----------�----1--------- � F. -+ — 4mL •----•--T------------------T------..-•----^� ___--____,..,5�-,____--____,..,� ____—____—____—____ II ____--___—____—_______—____ II ____—____—____--___ �. _. ________________ ------------------------------- -- -?-- --�w I! ------------------- ------------------- ------------------ ------------------- A- - - - - - - - , H L------------------1----------- - �;vl vlvl Vl I I I I T__________________T__________________�C-.-.--.--.--.-__-.-7 I' -- - - - - - - - -- l no I C20.01 I ---------------------- ___ _ ___--------------------------------- T' TtlT' nil; i i �� it it ii ----------------- ------ C20 3 -------------------y --------1------------------ 1------------------ _-====_=_=='� U ii - - ---- - ---- - ---- - ----- - ---- - ----- LL -----------------iiI--LL ---'i ��iou - ----------'d -------------------------------------- ------------------------------------------------------------ �,. 1 C2.01 C2.02 S C2 C2 ----------------------------------------------------------------DR------------ ----------------------------------------------- OR _____________________________________----------------------- ----- _______ _ _______________________________________________________ ------------------------------------------------------------------------------ ==-====-==-=-==-=====---------===-==-===-==-====-====-==-====-====-==-=- -=---------------------------------------------------==- Oo--------------------------- --------------------------------------------_,_ _-- -------- T------------------ T----- _____________ .1^-___ ^r^ J ^� C2, C20 S =1 1/81, SR = 7/8" L = 1/211 --------1------------------ 1---- --------------' -'--'-------- I"�"�--------w1 .. ,� I I ===r_c===_ rr _____________ _____________ _____________ _____________ _____________ --------T------------------T--------------...•��,"'—-___''-S"� _ J___''-� r' nbl�r$_____________ , r$_____________ , r$_____________ $_____________ ,I{I,$_____________ �7 ti \T i i kj 11 �I �] -- -_ -- --- - --- --- --------------------------- -- ` - -' +, , tF_= 17 LF_ -_====_3 fit______-______otF__--3 L-______�______3j� 1 'r5 --- - - ---------------- - - - ----------------------------------------------------- - - - - -- - - i --------L------------------1------------ --�f'v) _ (v�v) _ (vl r �br------------_-----------------------------ii _- _------ ---------- -]5M; -_ - - - -= ti "" --===_L-_=---f-�E = __ _ - ______�__=aerr== _�_----- _ _ _ _a_ _cam: __ ---- _ - _ i _ _____ --____ PARTIAL PIPING REFRIGERATION PLAN NORTH 1 /411 1'-011 ►E Cm N 66 M N O N N N 00 REFRIGERATION LEGEND SYMBOL DESCRIPTION OR REFRIGERATION CASE CONNECTION ® EPR WITH SUCTION STOP SOLENOID ® SUCTION STOP SOLENOID GENERAL NOTES 1. PIPING SHALL BE LOCATED SO THAT ACCESS TO THE SYSTEM COMPONENTS IS NOT HINDERED AND THAT ALL COMPONENTS THAT COULD REQUIRE FUTURE MAINTENANCE ARE EASILY ACCESSIBLE. 2. THE REFRIGERATION CONTRACTOR SHALL REVIEW AND STRATEGICALLY LOCATE ALL CONTROL VALVES PRIOR TO THE INSTALLATION OF ANY PIPING. 3. THE REFRIGERATION CASE MANUFACTURER SHALL FURNISH AND INSTALL ONE ISOLATION LIQUID LINE HAND VALVE IN EACH REMOTELY REFRIGERATED CASE FOR CLEANING AND MAINTENANCE PURPOSES. 4. DRAWING IS SHOWN PARTIALLY DIAGRAMMATICALLY FOR CLARITY PURPOSES ONLY. EACH REFRIGERATION LINE DISPLAYED ACTUALLY REPRESENTS A LIQUID AND SUCTION LINE PAIR PER CIRCUIT. 5. THE REFRIGERATION CONTRACTOR SHALL COORDINATE ALL PIPING PATHS TO AVOID CONNECTIONS WITH ELECTRICAL PANELS, HALLWAYS. ABSOLUTELY NO PIPING SHALL PASS ABOVE ELECTRICAL PANELS AND TRANSFORMERS OR THROUGH HALLWAYS. 6. THE REFRIGERATION CONTRACTOR SHALL COORDINATE ALL PIPING PATHS TO AVOID CONFLICTS WITH ALL OTHER TRADES. (I.E. HVAC EQUIPMENT, HVAC DIFFUSERS, DUCT WORK, FLUES, LIGHT FIXTURES, PLUMBING LINES, DECOR, PALLET RACKING, ETC.) 7. THE REFRIGERATION CONTRACTOR SHALL INVESTIGATE AND ENSURE COMPLIANCE WITH ALL FEDERAL, STATE, AND LOCAL CODES PRIOR TO INSTALLATION. THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES. 8. MOUNT OVERHEAD REFRIGERATION LINES EITHER INSIDE OR WITHIN 3" OF BOTTOM OF BAR JOIST. ALWAYS MAINTAIN PROPER SLOPE BACK TO THE COMPRESSOR RACK, IF NECESSARY INSTALL INTERMEDIATE RISERS TO MAINTAIN ABOVE ELEVATION. 9. SUCTION P-TRAPS TO BE SAME SIZE AS HORIZONTAL RUNS, REDUCE WITH BUSHINGS AT THE TOP SIDE OF P-TRAP. INTERMEDIATE P-TRAP SIZE SHOULD BE THE SAME SIZE AS REDUCED RISER. 10. TO FACILITATE MOVEMENT OF THE PIPING AS A RESULT OF CONTRACTION AND EXPANSION DURING REFRIGERATION OPERATION THE REFRIGERATION CONTRACTOR SHALL INSTALL EXPANSION LOOPS THROUGHOUT THE STORE'S REFRIGERATION PIPING IN FULL COMPLIANCE WITH THE ASHRAE STANDARDS AND LOCAL CODES AND REGULATIONS. PIPE HANGERS SUPPLIED AND INSTALLED BY THE REFRIGERATION CONTRACTOR MUST PERMIT FREE MOVEMENT OF THE REFRIGERANT LINES. 11. INDIVIDUAL REFRIGERATION BRANCH SIZES ARE SHOWN ON THE REFRIGERATION SCHEDULE. 12. REFRIGERATION CONTRACTOR TO WIRE AND TERMINATE ALL LOW VOLTAGE DEVICES. BELDEN 8762 OR EQUIVALENT. THIS WIRING SHOULD BE CAREFULLY ROUTED AWAY FROM POWER LINES OR OTHER HIGH ELECTRICAL NOISE ENVIRONMENTS. 13. AFTER LINES ARE INSTALLED REFRIGERATION CONTRACTOR TO FILL OPENINGS IN CASES WITH EXPANDING FOAM INSULATION. 14. UPON COMPLETION OF INSTALLATION, REFRIGERATION CONTRACTOR TO ENSURE ALTERED RACK UNITS ARE PROPERLY CHARGED WITH REFRIGERANT. 15. COMPLY WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS REGARDING REFRIGERANT RECLAIMING, SYSTEM EVACUATION, EQUIPMENT, OIL AND REFRIGERANT DISPOSAL. 16. COMPLETE THE APPROPRIATE W1NCO FOODS REFRIGERANT TRACKING FORMS AND PROVIDE DOCUMENTATION THAT ALL OTHER REGULATIONS HAVE BEEN COMPLIED WITH. 17. MECHANICAL PERMIT IS REQUIRED. CONTRACTOR TO SUBMIT FOR PERMIT SEPARATELY. THE MECHANICAL PERMIT SHALL INCLUDE THE FOLLOWING INFORMATION. ADDITIONAL INFORMATION MIGHT BE REQUIRED AFTER THE DRAWINGS HAVE BEEN REVIEWED. EXISTING EQUIPMENT, POINT OF CONNECTION AND SYSTEM INFO IF ANY. KEYED NOTES 1. REFRIGERATION CONTRACTOR SHALL INSTALL NEW CONTROL VALVE IN ACCESSIBLE LOCATION. CONTRACTOR TO COORDINATE PROGRAMMING WITH DC ENGINEERING. RE: R4 & R5. 2. REFRIGERATION CONTRACTOR SHALL INSTALL NEW SUCTION AND LIQUID PIPING OF C20 TO C2 PIPING ABOVE EXISTING C2 CONTROL VALVES. RE: R4. 3. REFRIGERATION CONTRACTOR TO VERIFY EXISTING SUCTION AND LIQUID LINES FOR C2 SYSTEM. CONTRACTOR TO REPLACE EXISTING C2 HORIZONTAL SUCTION LINES WITH NEW 1 1/8" PIPING. CONTRACTOR TO REUSE EXISTING C2 SUCTION RISER AND LIQUID LINES. NEW C2, C20 PIPE LOOP TO REUSE EXISTING C2 CONNECTIONS TO MAIN LOOP. RE: R4. REVISIONS ARCH. PROJECT NO. 23043 DRAWN DT CHECKED GH SUBMITTAL DATES OTB DATE �o 0 ,Udgu 4°© ED ? ; N a g Fo° W s m a �a��a°moo � v W d __ �'c? ¢"'`�ii;�' 00 Z y 3 W 3 �F�°Ama v 0 9;4°F a� " a� ch e b.hills architecture, PC 3156 south bown way boise I idaho 83706 p.208.2586150 www.bhillsarch.com Q' WAS ��.cFSRF�1741 /STERNG����� AL EN 9/ 18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT r--I N O� 00 F-L-I 11 1� O N W SHEET TITLE PARTIAL REFRIGERATION PIPING PLAN SHEET Multi -Deck Merchandiser with S}rnerg-Elm 05DM-NRG 4 ; 6 ; 8' & 121 (Beverage/ Dakyf Delil Prodirce)l y NSF ►E r----39 11116 in [100.7 and ROW LR[ FIT [OPTIONAL] 24 m 13" MIRROR (OPTIONAL; — - LOAD LIMIT 63 Soo In 24 in _ LIME [212.4 cm] := 66 W4 in ;� [141,J C3ri] :O :24 81 9J15 in : {207.2 cm] :a SS Jr. ;a [149-9 cm] 24 in STANDARD DDAIRY FRONT ;p 32 In �Bi-3 cm L_ i8 11116 in COIL LENU [47.5 cm] 14UZin [38.9 cm] O 0 5 1r8In 6 W19 In [17.2 tm� [i3.1 cm] 31 11A6 in [80.2 cm] 39 114 in 09.7 cm] 43 1 4 in 1100.14 em] 39 114 I n [99,7 cm] 43 ird in [149-9 cm] ELECTRICAL JUNCTION BOX (WRING PER LOCAL CODES) S" EXTENDED FRONT Wf NOSE LIGHT 231i [60,2111fi am]n 1S 1t2 in {49.6 cm] 7 1f2" EXTENDED FRONT Wt NOSE LIGi4T 21 3116 in [53.9 tm] 17 in [43.2 cm) PIPINi.'. TO THE TOP WIRFNG TO THE TOP 10PT1UNAL1 12 in ['[34,5 c L_35 in 4 in [10,20 [98, 9 cm] .. R€FRIGERATiON 29 Sid in 14' Case only) [72.7 cm] 7 V2" EXTENDED FRONT W+ NOSE LIGHT 713 all � in [56.6 cm] 22 in [55.9 cm] 6" EXTENDED FRONT 23 11t16 in ml 19IQ in [49.6 c m] REAR REFRIGERATION {14 112" Dfl of iloori m] 3 in [7.6 cm] m] 22 W15 in [57-3 cm] 285min [72.7 cm] 31 11AG in (60.4 cm] -------/---------_._._....�1-1_ 1 ir2' PVC DRAIN CONNECTION [4' case only) 1 112" PVC DRAIN CONNECTION FRONT OF CASE 4E In (121.9 cm) (4' case) 72 In [182-9 cm] (T case) 96 In (243.13 cm] 15' case} idd In [365.9 cm] (I2' case) NOTES: STUB -UP AREA RECOMMENDED STUB -UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS 1 REFRIGERATION W. 8', 12' casesl L1 1r2 in [3.8 cm] (END) 11118 In 122.1 cm] —12 In [30.5 cm] • FRONT SILL HEIGHT AND OV-ERALLCASE HEIGHT VARY WITH RASEFRAME HEIGHT • ENDS ADD APPROXIMATELY 1 INCH TO CASE HEIGHT • WIRING -TO -THE -TOP ADDS APPROXIMATELY 1 INCH TO CASE HEIGHT • A 2" MINIMUM AIR GA? 15 REQUIRED BETWEEN THE HEAR OF THE CASE AND A WALL • SUCTION LIFE 14' S 61-W", SUCTION 11.114C 8' & i2'I - 716", LIQUID LINE TALL LENGTHS) - 3V AVAILABLI= SHELF SIZES: 14", 12", 14", 16', 16". 20", 22" & 24" • DASHEO LINES SIGNIFY AREA INSIDE BASE RAIL BEHIND KICK -PLATE HILL PHOENIX 05DM-NRG NTS REDUCED RISER NOTE: P-TRAPS TO BE EITHER PRE -FABRICATED OR CONSTRUCTED WITH LONG RADIUS STREET 900 ELBOWS, CLOSE COUPLED. P-TRAP PIPING 3 NTS FULL SIZE RISER REVISION' 151009 1448 ROOF JOISTS - SEE STRUCTURAL DWGS LOCATE THEADED ROD AS CLOSE AS POSSIBLE TO PANEL POINT OF ROOF JOIST L1 L2 RACK CONTROL CIRCUIT POWER REFRIG °zb ° z SS I SS TPIT Y VY REFRIGERATION RACK/DFST PNL I I SOLENOID SALES FLOOR SOh SEE R4 FOR v \ LOCATION v W H 0 INPUT 3 POINTS 0(+) Q Q I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I r j T j r P ITPITPI l i p l i p I I I I I I I I I I I I I lal I � I IWI IHI 1 PER CASE TIME OFF DEFROST - DISPLAY FIXTURE AND COOLER EVAPORATOR CONFIGURATION NTS iEFRIGERATION PIPING TO BE RUN TIGHT TO BOTTOM OF STRUCTURE AND SLOPED TO COMPRESSOR RACK LOCATION. DOUBLE NUTS AND WASHER TYPICAL ALL LOCATIONS UNISTRUT HANGERS (ALL PIPING) REFRIGERATION LINES PERPENDICULAR TO JOISTS TYPICAL REFRIGERATION SUCTION/LIQUID LINE ARMAFLEX OR APPROVED PIPE INSULATION TRAPEZE CAN BE NO LOWER THAN 12" BELOW THE BOTTOM CHORD OF THE SUPPORTING STRUCTURE. TOP CHORD OF ROOF JOISTS BOTTOM CHORD OF ROOF JOISTS DOUBLE NUTS AND WASHER TYPICAL ALL LOCATIONS THREADED ROD PIPE CRADLE UNISTRUT HANGERS UNISTRUT HANGERS PIPE CRADLE REFRIGERATION LINES PARALLEL TO JOISTS TYPICAL HORIZONTAL INSTALLATION DETAIL REFRIGERANT PIPING DD n'r U r'rnD REFRIGERATION LINE SUPPORT NTS ELECTRICAL LEGEND SYMBOL DESCRIPTION L1 L2 SINGLE PHASE POWER L1 L2 L3 THREE PHASE POWER 0 0 o CIRCUIT BREAKER ° 3 POLE CONTACTOR 2 POLE CONTACTOR b 3 POLE q SINGLE POLE DOUBLE THROW b¢ RELAY (SPDT) q DOUBLE POLE bb DOUBLE THROW RELAY (DPDT) OUTPUT POINTS CONTROL BOARD OUTPUT RELAY zz°z INPUT POINTS CONTROL BOARD INPUT POINTS SINGLE POLE °� SINGLE THROW SWITCH (SPST) SINGLE POLE ❑ DOUBLE THROW SWITCH (SPDT) TEMP TEMPERATURE PROBE ° THERMOSTAT/ KLIXON o TERMINAL BLOCK DT DEFROST ° TERMINATION o TERMINAL BLOCK TS DUAL TEMP ° SOLENOID ° TERMINAL BLOCK o DUAL TEMP SWITCH o TERMINAL BLOCK SS REFRIGERATION ° SOLENOID(S) o TERMINAL BLOCK TP TEMPERATURE ° PROBE r( (R) INDICATOR LIGHT - RED r( INDICATOR j� LIGHT - GREEN ono SINGLE PHASE HEATER LOAD THREE PHASE HEATER LOAD SO 0+0 SOLENOID COIL REVISIONS ARCH. PROJECT NO. 23043 DRAWN CHECKED GH SUBMITTAL DATES OTB DATE �o 0 aw Ua 00 °aodo� oUd0.0 `4�© L7 W 2 o m Z _ N a P Fo° W s m a U 'xQSQ QQ6 �Qoa a W d Z % �6 - N C L7'c< m Z y 3 h K Q a L3 L O a d 0 �F a� ch C� V� P b.hills architecture, PC 3156 south bown way boise I idaho I 83306 p.208.258.6150 ww w.bhiIIsarch.c om �D H. M/! `<AP ,QQ` pF WASy�N S1741 ' FGISTE S/ONAL EN 9/ 18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT N O� O O� 00 O T� vim-- O � 00 O N W SHEET TITLE REFRIGERATION DETAILS SHEET REFRIGERATION SCHEDULE BELDEN #8762 rn o CASE AND COOLER SIZE x p x REFRIGERATION LINE DATA (See Note #2) FIELD VALVES (See Note #1) REFRIGERATION CONTROLS CASE/COIL ELECTRICAL REQUIREMENTS COMPRESSOR DATA REMARKS w REFERENCE EQUIP. SPEC. FANS (120 V) ANTI -SWEAT (120 V) CASE &CANOPY LIGHTS CASE DEFROST EEV DRIVER WALK-IN BOX COIL FAN AND DEFROST DEFROST AND FAN CONTROL F !� (See Note #5) (See Note #5) (120 V) (208 V - 1Q' OR 34•) (120 V) W p w Z c9 O U m N w z L W H AREA m BELOW FOR MANUFACTURER AND MODEL N0. w > m > m > m W > m > m m x Z o w w x a m O m W (SQ.FT.) o gLL of Z 0 W N w x W m (See Note #1) m O w Y o Z U W m w 0 m x a Z Q W Z MANUFACTURER AND ¢ W O LL w z H y U ¢ w Z w m W F w N W F w m W F W fn ro ¢ w F K w F H ¢ W W LL. Z 0 m m W ~ m w w FIXTURE DESCRIPTION MODEL NO. REFERENCE x Z a vi w Z ? > ¢ N W ~ F ¢ w ¢ m > ¢ N > ¢ m > W x ¢ U U N r W > m > J o= m O 0 Z _ Jo o w w 0 ~ 0 z z of (See Note #3 W ~ z w w rn z J J ¢ o 0 m U Z O W w N m o w w m N O w w N m N m O w LL Of ¢ m a z m 3 W W W Z Z Z W m Z 0_ W W K W N o o LL F p- w F w 7 0 N N W W ¢ m ¢ N W fn W W J W W w W y ¢ K W fn ¢ 2' W N ¢ K K K K 2' K U u) LL W K 7 rn LL W K F Z O F LL. W LL Z 0 U' Z LL x K W W LL ¢ F� ow LL o_ Kw z O W w K w w ~ N N 0 w ¢ m >W� W w _ J LL u) ¢ LL m ¢ w x ¢ U U w LL x ¢ V U w LL x ¢ V U w LL w LL W LL W LL w a W a Wa a m0 0 o ~ UK K K¢ 7Z O�" U O K F W �K QQ W o_ K W zw pj K K W K K c Kin m H z W LL W W U x y W W rn 0LL ¢7 W 7 H x x z z W m Z W Z LL Z '-' ti ¢ln �. > LL m� > ,-. LL W O ao m a O co N a O co m a cn cn cn N o- W m a ¢ N a U ¢ O o t- ¢ p o ro N Z Kw LL W F O 2 (n LL O m O (n O O r aa fY K W w fn ¢ ¢ U w0 K J w~ U' ~ K� U 7 d m J Z Z J F J Z Z J 7 0 W >w 0 zW0 W W x W x W x x W W x x x a a a O U y LL ¢ LL H� Z rU ¢ �F W FK O U z 00 o� aK r K 0~ 7� c0U W coo W rn ?? W F u) W F m W F O w lq O K W K x F U W O Z W ¢ W m N O O to O Z1e GULL_ ;Z W 0 LL Z J 7 LL mom' O ¢F a ¢t= a a d ¢F ¢ ¢ ¢ ¢F W d ¢F LL LL� W W w ¢ w W O Y N¢ OZ O > U m W 01 LL �F 0m N O Nw az a a� aU aU aU LL (7 LL W m m F (7 N x D_ h Y U x W In Q F F U U 0 0 Y U F U 0 0 FqU O fYYU o YU 0 zZ ¢ W F N m LL y0 LL O ui0 LL O > < H N LL N LL m LL > Q m LL N LL N LL > ¢ H > ¢ H N ¢ LL > ¢ H O ¢ w ¢F H N ¢ y 0 J y ¢ ¢ F y ¢ 0 J U¢ W fY LL J pw p Ka LL W O �¢ Z U W fY LL w F (n YD_ U cC ¢ LL' ¢ rC d ¢ rC d ¢ D_ N N [Y LL w w r x O O 0 00 0 ww w QQ m ¢ O > > d ¢ 0 O U W OFa LL U W Lugo- U W 0Q a LL N x °' r �0 g0 O- O- o- amp m amp m amp m O- x o- o Z ¢ N or x O o x O x o Z ¢� w 2 K w� O op 0 w > qaw 00 00 0¢ 0¢ 0¢ ¢ w F tq LL z z z FZ z OF �F K 2U F V1 ro G' N N N pU �Km wry N ¢ ¢v ¢u� FU ¢ ¢ ¢ FU ¢ ¢ ¢ FU FU a ¢ FU z LL FN a > U a F a > LLm �et5 LL moo_ Om z UJ �i2 cn F UZ Ux UU UU UU of 0 2 C1 PRODUCE COOLER 34 20 14 696 2 WK-270 B 30 38 44.8 7/8 1 3/8 5/8 1 1/8 1/2 1/2 3 1/8, 1 1/8 1 3/8 1/2 ME35S1110 (F) ME6S140 (F) (2) SBFJE-B-JC C1 3.6 7.2 2 2 RACK C 4 TO C1 0 2 C2 MID PRODUCE CASES 2 16 DX6LN KW 28 33 18.8 7/8 7/8 1/2 LOOP SEE C1 7/8 1/2 ME19S290 (F) BY CASE OEM C2 0.2 0.4 0.4 1.0 1.4 1.9 2 R.P. #4 4 TO C2 0 3 C3 MID PRODUCE CASES 2 1 28 DX6LN KW 28 33 32.9 1 1/8 7/8 1/2 LOOP SEE C1 1 1/8 1/2 ME25S290 (F) BY CASE OEM C3 0.2 0.4 0.8 1.0 1.4 3.4 2 R.P. #4 4 TO C3 0 4 C4 MID PRODUCE CASES 4 48 DX6LN KW 28 33 56.4 1 5/8 1 3/8 1/2 LOOP SEE C1 1 5/8 1/2 ME35S1110 (F) BY CASE OEM C4 0.2 0.4 1.6 1.0 1.4 5.8 2 R.P. #4 4 TO C4 25 4FES-3Y-4SU 3 27.4 25.3 35.3 441 134a 0 1 C5 MID BAG SALAD CASES 1 12 DX6LN KW 28 33 14.1 7/8 3/4 1/2 LOOP SEE C1 7/8 1/2 ME14S270 (F) BY CASE OEM C5 0.2 0.4 1 0.4 1.0 1.4 1.4 2 R.P. #4 4 TO C5 25 4VES-7Y-2NU 7 54.5 50.4 70.3 877 134a 0 3 C6 MID DRESSING/JUICE CASES 2 1 28 DX6LN KW 28 33 32.9 1 1/8 1 1/8 1/2 LOOP SEE C1 1 1/8 1/2 ME25S290 (F) BY CASE OEM C6 0.2 0.4 0.8 1.0 1.4 3.4 2 R.P. #4 4 TO C6 25 4HE-15Y-2NU 15 121.6 1 112.5 156.8 1 1956 134a 0 1 C7 REACH -IN DELI PROMO CASE 1 12 DX7LD KW 28 34 3.4 1/2 1/2 1/2 LOOP SEE C1 1/2 1/2 ME6S140 (F) BY CASE OEM C7 2.4 2.4 0.4 0.4 2 R.P. #4 4 TO C7 0 1 C8 DELI WRAP 19 14 8.75 259 1 WK-155 B 28 41 17.9 7/8 718 1/2 7/8, 1/2 7/8 1/2 ME14S270 E5S140 SBFJE-B-JC C8 1.8 1.8 1 RACK C 4 TO C8 25 203.5 188.2 262.4 3274 C9 SPARE 1 5/8, 5/8 C9 C9 -20% -26% 4% 0 1 N ( ) C20 MID PRODUCE CASE 1 8 05DM-NRG HP 28 33 9.3 314 N I) 518 N ( ) 318 N ( ) LOOP SEE C1 314 318 SPORT-115-7 N F ( ) O EEV & DRIVER BY OEM C20 0.5 0.5 0.2 0.2 0.4 0.4 2 R.P. #4 2 TO C20 RACK C, GROUP 1 25 230.4 253.5 RACK C, GROUP 1 RACK C, GROUP 1 110% 0 1 C10 BULK FOODS 32 16 10 492 1 SM-052 B 40 65 11.0 314 5/8 112 314,1/2 SORIT-12-718 E3S140 SBFJE-A-JC C10 0.9 0.9 1 RACK C 4 TO C10 0 1 C11 PRODUCE DRY ROOM 29 21 14 621 2 WK-155 B 40 55 40.8 7/8 1 318 5/8 1 1/8 1/2 1/2 1 3/8, 1/2 SORIT-12-1 118 ME6S140 (2) SBFJE-B-JC C11 1.8 3.6 2 RACK C 4 TO C11 0 1 C12 SUBCOOLING RACK A Enth. Change 21.9 4574 3659.2 40 100.3 10.03 1 518 1 3/8 5/8 1 518, 518 ORIT-20-1-5/8 ME6S140 SBFJE-C-JC C12 NA C12 (2) MElOS250 OJE-6-JC 0 1 C13 SUBCOOLING RACK B Enth. Change 22.4 10731 8584.8 40 240.2 50.05 2 5/8 2 1/8 1 3/8 1 1/8 2 5/8, 1 1/8 PORT-21-21 MElOS250 SBFJE-C-JC C13 NA C13 37 4VES-7.F3-0OS 7 96.9 89.6 133.2 1626 134a (2) ME19S290 OJE-6-JC 0 1 C14 SUBCOOLING RACK C Enth. Change 22.4 11456 9164.8 40 256.4 85.46 2 5/8 2 1/8 1 1/8 2 518, 1 1/8 PORT-21-21 MElOS250 ME19S290 SBFJE-C-JC OJE-6-JC C14 NA C14 37 4DES-5Y-40S 5 57.1 52.9 73.1 892 134a C15 AHU-2 STAGE #1 (See Note #8, #14) 45 34.2 1 1/8 2 1/8 7/8 1 5/8 1/2 718 2 118, 718 ORIT-20-1-518 ME6S140 (F) SBFJE-C-JC (F) C15 C15 37 4NES-14Y-40P 14 121.8 112.7 155.8 1903 134a C16 AHU-2 STAGE #2 (See Note #8, #14) 45 34.2 1 1/8 7/8 1/2 LOOP SEE C16 ME6S140 (F) SBFJE-C-JC (F) C16 C16 37 6HE-28Y-2NU 28 241.0 223.0 308.0 3761 134a C17 AHU-2 STAGE #3 (See Note #8, #14) 45 34.2 1 1/8 T8 1/2 LOOP SEE C16 ME6S140 (F) SBFJE-C-JC (F) C17 C17 C18 AHU-2 STAGE #4 (See Note #8, #14) 45 34.2 1 1/8 718 1/2 LOOP SEE C16 ME6S140 (F) SBFJE-C-JC (F) C18 C18 54 516.8 478.2 670.1 8182 C19 SPARE 1 5/8, 5/8 C19 C19 -22% -28% 1% RACK C, GROUP 2 37 785.2 665.8 RACK C, GROUP 2 RACK C, GROUP 2 79 720.3 666.4 932.5 11456 85 RACK C TOTAL 1,015.6 919.3 RACK C TOTAL 0.0 0.0 0.0 15.0 15.0 20A 1 0 RACK C TOTAL Notes: 1) Supplied and installed by Contractor. Mounted at rack unless specified (F) Field. See R2 drawing forfield location. 2) Individual branch line sizes. For common (loop) sizes see R2 drawing. 3) Manufacturers: (B) Bohn, (KW) Kysor Warren, (HP) Hill Phoenix. 4) Canal EEV's supplied by OEM's. Cases to include EVD Evolution (Or Evolution Twin) valve driver with Ultracap module factory wired and installed on case unless noted otherwise. Each Evolution driver to include 40vA transformer w/2A Type T Fuse before and after the transformer. Power to EEV shall be supplied from an uncontrolled circuit. 5) Display fixture electrical loads showing no amps in the anti -sweat location on schedule have the "no pulse" anti -sweat loads included in the fan amp load ►E Cm 0 M OD M N O N N N 00 REVISIONS ARCH. PROJECT NO. 23043 DRAWN DT CHECKED GH SUBMITTAL DATES OTB DATE 5o 0 oU°a0.OxU°© x Z ._ � F a Fo° °mom � WED s __ Z I 3 N 310 W p m � � r �UGGma OW N j L3 0 t 0 V� a� ch � C P b.hills architecture, PC 3156 south bown way boise I idaho I 83306 p.208.258.6150 ww w.bhiIIsarch.c om �pH.M/! G1741 ISTER�G����'� S/ONAL EN 9/ 18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES M DEPARTMENT N uu O O O L� N W SHEET TITLE REFRIGERATION SCHEDULE SHEET REMOTE 4 OPTO-22 BOARD ASSIGNMENTS MODULE 0 8 CHANNEL ANALOG INPUT MODULE # SNAP-AIR-40OK-8 0 A34.01 REACH -IN FRZN FD TEMP 1 CO2.01 MID PRODUCE TEMP 2 CO2.02 MID PRODUCE TEMP 3 CO3.01 MID PRODUCE TEMP 4 CO3.02 MID PRODUCE TEMP 5 CO3.03 MID PRODUCE TEMP 6 ICO4.01 MID PRODUCE TEMP 7 1 C04.02 MID PRODUCE TEMP MODULE 2 4 CHANNEL DIGITAL INPUT MODULE # SNAP-IDC5-SW 0 A34 REACH -IN FRZN FD DEFROST TERM STAT , 2 3 MODULE 4 4 CHANNEL DIGITAL OUTPUT MODULE # SNAP-OAC54 0 C05 MID BAG SALAD REFRIGERATION CMD 1 C06 MID DRESSINGIJUICE REFRIGERATION CMD 2 C07 REACH -IN DELI PROMO REFRIGERATION CMD B CI MID PRODUCE REFRIGERATION CMD N MODULE 6 4 CHANNEL DIGITAL OUTPUT MODULE # SNAP-OAC54 0 B07 PRODUCE END CAP REFRIGERATION CMD 1 BOB PRODUCE END CAP REFRIGERATION CMD 2 B09 PRODUCE END CAP REFRIGERATION CMD 3 MODULE 1 8 CHANNEL ANALOG INPUT MODULE # SNAP-AIR-40OK-8 0 C04.03 MID PRODUCE TEMP 1 C04.04 MID PRODUCE TEMP 2 CO5.01 MID BAG SALAD TEMP 3 C06.01 MID DRESSING/JUICE TEMP 4 C06.02 MID DRESSING/JUICE TEMP 5 C06.03 MID DRESSING/JUICE TEMP 6 C07.01 REACH -IN DELI PROMO TEMP 7 C20.01 MID PRODUCE TEMP N MODULE 3 4 CHANNEL DIGITAL OUTPUT MODULE # SNAP-OAC5.1 0 A34 REACH -IN FRZN FD DEFROST (ELI CMD 1 CO2 MID PRODUCE REFRIGERATION CMD 2 CO3 MID PRODUCE REFRIGERATION CMD 3 C04 MID PRODUCE REFRIGERATION CMD MODULE 5 8 CHANNEL ANALOG INPUT MODULE # SNAP-AIR-40OK-8 0 B07.01 PRODUCE END CAP TEMP 1 B07.01 PRODUCE END CAP TEMP 2 B07.01 PRODUCE END CAP TEMP 3 4 5 6 7 MODULE 7 0 1 3 MODULE 8 MODULE 9 # # 0 0 2 2 3 MODULE 10 MODULE 11 # # 0 0 2 2 3 MODULE 12 MODULE 13 0 0 2 2 3 MODULE 14 MODULE 15 # # 0 0 , 2 2 3 3 Power supply by Phoenix Contact Model #TRIO-PSIIACI5DCI10 (mounted on DIN rail) NOTE: CONTROLLER/MODULES AND POINTS ARE EXISTING UNLESS MARKED (N) NEW. ►E O M 00 M N O N N N 00 NOTE MINIMUM 2 WEEKS PRIOR TO THE START OF CONSTRUCTION, THE REFRIGERATION CONTRACTOR MUST EMAIL THE FOLLOWING INFORMATION TO THE ADDRESSES BELOW: MICHAEL. TRANAWINCOFOODS. COM, WINCOINTEGRATIONgDCENGINEERING.NET, AND THE GC FOREMAN. EMAIL SHALL HAVE A SUBJECT LINE INCLUDING WFIP STORE NUMBER, DEPARTMENT UNDER CONSTRUCTION, AND REFRIGERATION SYSTEM NUMBER. EMAIL BODY SHALL INCLUDE THE FOLLOWING INFORMATION: • STORE NUMBER, CITY AND STATE • DEPARTMENT UNDER CONSTRUCTION • REFRIGERATION SYSTEM NUMBERS UNDER CONSTRUCTION • SPECIFIC CONSTRUCTION SCHEDULE DATES • SPECIFIC DATE AND TIME OF SYSTEM STARTUP. MUST SCHEDULE A SPECIFIC TWO HOUR BLOCK. • NAME AND PHONE NUMBER OF SINGLE POINT OF CONTACT FOR REFRIGERATION CONTRACTOR RESPONSIBLE FOR STARTUP. ALL COMMUNICATION WITH DC ENGINEERING MUST BE THROUGH THE WINCOINTEGRATIONgDCENGINEERING.NET.NET EMAIL ADDRESS, AND THEY WILL CALL YOU BACK. REVISIONS ARCH. PROJECT NO. 23043 DRAWN DT CHECKED GH SUBMITTAL DATES OTB DATE E'o 0 oU°a0.OxU °© x Z .2 � F 0. gc1F p.°. cm, � W O .� °' a W Z ❑ . __ �aQKmaO� � 6a c? 00 Z �1 3 N 3 W O'F�4Z�V�� O J j �O lb a� ch P b.hills architecture, PC 3156 south bown way boise I idaho I 83306 p.208.2586150 www.bhillsarch.com �pH.M/! ,QQ` pF WASy�N G1741 ISTER�G����'� S/ONAL EN 9/ 18/23 RECEIVED Oct 02 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JM N • O� O O� 00 V 1 T � O O O O N W SHEET TITLE CONTROL I/O POINTS SHEET