Loading...
APPROVED BLD PLN FIR BLD2023-1407+Architectural_or_Building_Floor_Plans+11.3.2023_10.56.26_AM+38797661 1 /3/2023 10: 1 5:54 AM P R A W I G I P E X 0 J FC T I N F O L F TH15 GRAPHIC DOES NOT MEASURE 2" THE DRAWI NG HAS BEEN SCALED. L � � N � � � � I' I' 0 1 2 PROJECT SITE G 100 TITLE PAGE PROJECT IS A CHANGE OF USE ANALYSIS FOR A RELOCATED PRE-SCHOOL r—I EPMONPS PRESBYTERIAN CHURCH G 101 BUILDING CODE ANALYSIS INTO AN EXISTING CHURCH. THIS PROJECT IS PROPOSED AS A CHAPTER 5 22060 g6TH AVENUE WEST Alderwood Manor A 100 SITE PLAN PRESCRIPTIVE APPROACH FROM THE IEBC. SEE SHEET G 101 FOR 12404 REGISTERED E Q 0 DS A200 EXISTING FLOOR PLAN FURTHER CODE ANALYSIS, ARCHITECT EPMONPS, W% g5020 A201 LIGHTING PLAN 63 4.; 1— A R C F L I I� � 0 f' R 0 J F G T T F A M BRYAN H. SCHUTT STATE OF WASHINGTON BRIER ADDRESS: EDMONDS PRESBYTERIAN CHURCH PROJECT NAME: E.C.P. PARTIAL CHANGE OF USE Esperanre MOUNTLAKE 22GOO 9GTH AVENUE W TERRACE EDMONDS, WA 98020 APPLICANT: EDMONDS CO-OPERATIVE PRE-SCHOOL WOODWAY 20000 G8TH AVENUE W, LYNNWOOD, WA 9803G TENANT: EDMONDS CO-OPERATIVE PRE-SCHOOL CONTACT: CHRISTINA COLE, CHIARPERSON, 20G-G39-8513 20000 G8TH AVENUE W, LYNNWOOD, WA 9803G EDMONDSCOOPPRESCHOOLCHAIR@GMAIL.COM Richmond d 5NOHOM15H COUNTY TRACT ID: 00575300000500 OWNER: EDMONDS PRESBYTERIAN CHURCH 22GOO 9GTH AVENUE W LEGAL DESCRIPTION: LOT 5, WESTVIEW ESTATES EDMONDS, WA 98020 Y 1 C I N I T 1 M A F SECTION -TOWNSHIP -RANGE: SE 1/4 5EC25 T27N R3E ARCHITECT: BRYAN SCHUTT, ARCHITECT 71 1 STATE STREET S KIRKLAND, WA 98033 �I *� Z O N I N G �I I N F 0 CONTACT: BRYAN SCHUTT, 40G-250-99G3 won.�. a.. — BHS BRYANSCHUTTARCHITECT.COM -lei=fir• PROJECT ADDRESS = 220GO 9GTH AVENUE W EDMONDS, WASHINGTON 98020 _. 1p LOT ZONING = R5-8 MIN LOT AREA — 8,000 SF ` �. -.,..,t MN LOT WIDTH = 75 FEET PKOJ ECT SITE MAX LOT COVERAGE 35% liw. -� �• .: .= - - — : r �•' - �# 14f �- i t - EXISTING LOT SIZE = EXISTING LOT COVERAGE _ 1.8 ACRES (-78,408 SF) 8,3% (FOOTPRINT /LOT SIZE) . , ,..� � � , r� � j 'I�i E h �k � + � _ � � � r,; r SETBACKS FRONT = 25 FEET SIDE 7.5 FEET — REAR 15 FEET NF 'wr 7j( ^�i- J } � ALL RIGHT5 RESERVED BY BRYAN 5GHUTT, ARCHITECT , . '.t: �, 2 w,. ; � ,1 _ ,. ■ - ,�! . ; r .� '�' � , � �* . ��' � ;�. t I * „ � ' �'. � { �� t►~ ©DO NOT REPRODUCE WITHOUT SPECIFIC PERMISSION 1 -, >t,LV P ..� •tl • :E .l a '; .i Aw e t. 'r i.\� i�. ..�'"i�• ..� ,�� - _ i ' �r1 j An t`''� -• *.• i{ �ai�l .� �.r 71 t `_ _� - —7 7l — N E I S H 5 0 R H 0 0 P AERIAL SITE AERIAL VIEW BRYAN SCHUTT ARCHITECT ARCH ITECTURAL ABBREVIATIONS ARCH ITECTURAL SYMBOLS MATFRIAL GRAPH ICS Phone:406.250.9g63 www.BRYANSC HUTTARCH ITEGT.ccm AB ANCHOR BOLT DS DOWNSPOUT GA GAUGE N NORTH S SOUTH TAGS SYMBOLS LINE 5YMBOLS BUILDING MATERIALS 51TE iORK MATERIALS AFF AGGR ABOVE FINISHED FLOOR AGGREGATE DWG DRAWING GALV G.B. GALVANIZED GRAB BAR N.I.C. NO NOT IN CONTRACT NUMBER S.C. SOLID CORE SCHED SCHEDULE ROOF TAG OA WINDOW TAG GHNG OF USE ALUM ALUMINUM E EAST G.C. GENERAL CONTRACTOR NOM NOMINAL SECT SECTIONS RI 1 — — — — — — — — — — — ALT ALTERNATE EXISTING GL GLASS N.R. NON S.F. SQUARE FOOT A101 REBAR IN SIDE OR PLAN VIEW APPX APPROXIMATE (E) EA EACH GR GRADE NTS -RATED NOT TO SCALE SHT SHEET C I CEILING TAG R1 REVISION TAG BUILDING SECTION _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ppLlr,T10� CONCRETE BRICK SECTION EARTH - BACKFILL EARTH - NATIVE �+ ARCH ARCHITECTURAL E.J. E.I.F.S. EXPANSION JOINT EXTERIOR INSULATION GYP GWB GYPSUM GYPSUM WALLBOARD O.C. ON CENTER SIM SIMILAR SPEC SPECIFICATION x'-xx' �� CEILING HEIGHT 1 SELF -ADHERED FLASHING � rc, - rcr_ � FOR BD BOARD AND FINISH SYSTEM O.C.E.W. ON CENTER EACH WAY SQ SQUARE w x - WALL TAG �' — SPECIALTIES TAG A101 WEATHER BARRIER E;MON;B CO -OF PRESCHOOL BLDG BUILDING ELEC ELECTRICAL H.B. HOSE BIBB O.D. OUTSIDE DIAMETER S.S. STAINLESS STEEL WALL SECTION -RESISTANT CMU MORTAR GRAVEL 3/4 MINUS GRAVEL DRAIN ROCK LARGE BLK BLKG BLOCK BLOCKING ELEV EMER ELEVATION EMERGENCY H.C. HIC HOLLOW CORE HANDICAPPED OH OPG OVERHANG OPENING STAGG STAGGERED STD STANDARD FLOOR TAG X- I - PLUMBING FIXTURE TAG SIM VAPOR BARRIER _ AT BM BEAM ENCL ENCLOSURE HDWD HARDWOOD OPP OPPOSITE STIFF STIFFENER A101 DETAIL SECTION EDMOND5 FRIBBYTERIAN CHURCH 13.0. BOT BOTTOM OF BOTTOM EQ EQUIV EQUAL EQUIVALENT H.M. HK HOLLOW METAL HOUR OTS OPEN TO STRUCTURE STL STEEL STRUC STRUCTURAL DOOR TAG 0 A �� O - PLAN NOTE PROPERTY LINE GROUT GLASS GRAVEL 3/4 MINUS 2 GRAVEL CLEAN CRUSHED 22600 g6TH AVENNE WEST BTWM B.W. BETWEEN BOTH WAYS EXPM E.W. EQUIPMENT EACH WAY HT HVAC HEIGHT PCT HEATING, VENTILATION PL PRE -CAST PLATE SUSP SUSPENDED 1'- 0` X 1' - 0"— DOOR SIZE ,4101 INTERIOR ELEVATION - -Ilin CENTERLINE EDMOND5, WAS Q5020 BYND BEYOND E.W.C. EXP ELECTRICAL WATER COOLER EXPANSION AND AIR-CONDITIONING P.L. P. LAM. PROPERTY LINE PLASTIC LAMINATE TR TREAD T*B TOP AND BOTTOM OILSPOT ELEVATION ✓✓ - WORK POINT A A A A A A A A I\N ALUMINUM BRASS GRAVEL 1-112 MINUS GRAVEL SANDY CRUSHED C-C C.H. CENTER TO CENTER COAT HOOK EXTR EXTERIOR I.D. INSUL INSIDE DIAMETER INSULATION PLAS PLYWD PLASTER PLYWOOD TER TERRAllO T*G TONGUE * GROOVE C-TOP DATUM POINT A101 EXTERIOR ELEVATION BATT INSULATION TITLE PAGE CJ CONTROL JOINT F.A. FIRE ALARM INTR INTERIOR PR PAIR THK THICK 32' AFF -' - CL CLG CENTERLINE CEILING F.L. F.D.C. FLOOR DRAIN FIRE DEPARTMENT CONNECTION JAN JANITOR PT P.T.D. PRESSURE TREATED PAPER TOWEL DISPENSER THRU THROUGH T.O. TOP OF WOOD- I TILE-2 MATERIAL, PLANE, OR 0 - GRID NAME AND GRIDLINE CONTINUOUS FRAMING STEEL BAR GRATING RIP RAP SMALL SITE - ASPHALT PLAN VIEW CLKG CAULKING CENTERLINE FDN F.E. FOUNDATION FIRE EXTINGUISHER JNT JST JOINT JOIST Q.T. QUARRY TILE T.O.W. TOP OF WALL T.P.D. TOILET PAPER DISPENSER PHASE TRANSITION CUR C.M.U. CLEAR CONCRETE MASONRY UNIT F.E.C. F.F. FIRE EXTINGUISHER CABINET FINISHED FLOOR KIT KITCHEN R RISER T.T.D. TOTAL TRAVEL DISTANCE TYP. TYPICAL 2997 NORTH ARROW BLOCKING MDF FIBERBOARD INSULATION - RIGID RIP RAP MEDIUM SITE - ASPHALT SECTION COLM CONC COLUMN CONCRETE F.H.C. FIN FIRE HOUSE CABINET FINISH LAB LABORATORY R.D. REF ROOF DRAIN REFER TO U.N.O. UNLESS NOTED OTHERWISE CONTOUR LINE ALIGN WOOD SHEATHING CONN CONST CONNECTION CONSTRUCTION F.L. FLR FLOW LINE FLOOR LAM LAV LAMINATE LAVATORY REFR KEINF REFRIGERATOR REINFORCED VCT VINYL COMPOSITION TILE ALIGN SURFACES INDICATED CONT CONTINUOUS FLR'G FLOORING LT LIGHT REQ'D REQUIRED VER VERIFY REVISION TAG AND CLOUD WOOD TRIM SECTION GYPSUM PLASTER INSULATION, SEMI -RIGID RIP RAP LARGE GRASS C.P.O.T. COMMON PATH OF TRAVEL C. TILE CERAMIC TILE FLUOR FND FLUORESCENT FOUNDATION MAX MAXIMUM RM R.O. ROOM ROUGH OPENING VERT VERTICAL R1 -2 I/211 CHANGE IN FLOOR LEVEL 0 ® R6Y1510I15: SUBMIT FOR BLDG. PERMIT F.O. FACE OF MECH MECHANICAL KWL RAIN WATER LEADER W WEST AREA NAME AREA TAG � CHANGE IN FLOOR SLOPE - UP MANUFACTURED TRIM SECTION DEG DEGREE F.O.BM FACE OF BEAM MEMB MEMBRANE W/ WITH 150 FOAM CLOSER INSULATION - SPRAY FOAM GATT INSULATION SHRUBS DTL D.F. DETAIL DRINKING FOUNTAIN F.O.0 F.S. FACE OF CONCRETE FULL SIZE MFR M.H. MANUFACTUKER(S) MAN HOLE W.C. WATER CLOSET WD WOOD ROOM name ROOM TAG CHANGE IN FLOOR SLOPE - DOWN GPYSUM SHEATHING DIAG DIAGONAL FT FOOT OR FEET MR MIRROR W/0 WITHOUT Date: NOV 5, 202E DIAor 0 DIAMETER FTG FOOTING 1 0 1 12 DN DOWN FR'G FURRING G 2 ROOF SLOPE INDICATION GPYSUM WALLBOARD WOOD END GRAIN WOOD FACE GRAIN SHINGLES FENCING E DOOR #G 3G" WIDTH 180 CAPACITY DOOR #5 3G" WIDTH 180 CAPACITY 0 E u DOOR # 1® 72" WIDTH 3GO CAPACITY 4IFW'N OF GE KITCHEN 1 O 5F ENTRY O 236 5F OGGP 2 OCGPS 223 SF RESTROOMS i FELLOWSHIP HALL q60 5F 65 OCCPS DOOR #4 3G" WIDTH 180 CAPACITY - i SANCTUARY OPE 108 OGGf LONGE5T EXIT PATH = — 1 12 FEET TOTAL EXIT PATH = —88 FEET SANCTUARY SEATING 1020 5F 114 OGCPS HALLWAY 450 5F OPEN COURT • • • ••••• • • r-- • • 7• TOTAL EXIT PATH C.P.O.T = • _ —80 FEET —33 FEET AGE 4 MEG SANCTUARY STAGE 212 5F 504 5F 35 OCCPS OGGUPANT GALGS AND EXITING PATHS 1/8" = 1'-0" • O O • STORAGE • 242 SF • � 10GGP • C.P.O.T i OFFICES "1 7 551 SF 4 OGCPS rr - / 41 5F CLASSROOM 1 445 SF 22 OCCPS TOTAL EXIT PATH _ -39 FEET DOOR #2 3G" WIDTH \ 180 CAPACITY ,r I 1 DOOR #3 3G" WIDTH TOTAL EXIT PATH 180 CAPACITY = —35 FEET CLASSROOM 2 416 SF 20 OCGPS EXITING ANALYSIS OCCUPANT LOAF (PER IBC SECTION 302 AND TABLE 1004.5) SEE OCCUPANT LOAD CALCULATION ON TH15 SHEET. MEANS OF EGRESS, SIZING (PER IBC SECTION 1005) SEE LIFE SAFETY AND EXITING PLANS ON TH15 SHEET. STAIRWAYS: .3" PER OCCUPANT DOORWAYS: .2" PER OCCUPANT 291 TOTAL OCCUPANTS = 55.2 INCHE5 OF DOOR WIDTH TOTAL 15 REQUIRED. EX15TING CONFIGURATION PROVIDE5 180 INCHES OF TOTAL WIDTH, THEREFORE 15 COMPLIANT. ARRANGEMENT OF EXITS PER IBC SECTION I OOG 5EE LIFE SAFETY t EXITING PLAN5 TH15 5HEET. PER IBC 908.5.1, FACILITIE5 HOU5ING MORE THAN 5 BUT LE55 THAN 100 CHILDREN UNDER AGE 2.5 YEAR5 THAT ARE LOCATED ON THE LEVEL OF EXIT D15CHARGE AND HAVE AN EXTERIOR DOOR ARE CLA551FIED A5 E OCCUPANIE5. TH15 PROJECT CONFORM5 WITH TH05E REQUIREMENTS. TRAVEL 171STANCES (PER IBC SECTION I OOG AND TABLE 1017.2) SEE LIFE SAFETY t EXITING PLANS TH15 SHEET. MAXIMUM COMMON PATH OF TRAVEL WITHOUT SPRINKLER SYSTEM OCC LOAD < 30 OCC LOAD > 30 A USE = 100 75 E USE = 75 75 MAXIMUM TRAVEL D15TANCE WITHOUT SPRINKLER 5Y5TEM At E USES = 200 FEET EX15TING CONFIGURATION COMPLIES WITH TH05E REQUIREMENTS, THEREFORE PROJECT 15 COMPLIANT. OCCUPANT LOAD CALCS LOADING ROOM SIZE AREA USE FACTOR OCCUP LOAD FELLOW5HIP HALL 9GO 5F A-3 15 G4 KITCHEN 23G 5F A-3 200 2 SANCTUARY OPEN SPACE 370 5F A-3 15 25 SANCTUARY SEATING 1020 5F A-3 FIXED SEATING 1 14 SANCTUARY STAGE 504 5F A-3 15 34 3090 5F 239 CL05ET 41 5E ACCE550KY 300 1 OFFICE 1 10 5F ACCE550KY 150 1 OFFICES 557 5F ACCE550KY 150 4 5TORAGE 242 5F ACCE550KY 300 1 5TORAGE * MECH 212 5F ACCE550KY 300 1 1 IGI 5F 8 CLA55ROOM 1 445 5F E 20 23 CLA55ROOM 2 41 G 5F E 20 21 5GO 5F 44 ENTRY 223 5F NON -OCCUPIED 0 HALLWAY 430 5F NON -OCCUPIED 0 RE5TROOM5 22G 5F NON -OCCUPIED 0 879 5F 0 5990 5F TOTAL OCCUPANTS = 291 PROJECT SUILDINS CODE ANALYSIS PROJECT NARRATIVE PROP05ED PROJECT 15 A CHANGE OF OCCUPANCY PERMIT TO RE -LOCATE A PRE-5CHOOL (E-U5E EDUCATIONAL) INTO AN EX15TING CHURCH (A-3 ASSEMBLY USE). THE PROP05ED PRE-5CHOOL WILL ACCEPT CHILDREN DOWN TO AGE TWO YEAR5, WITH A MAX OF 8 CHILDREN UNDER 2.5 YEARS AT ANY ONE TIME. THE EX15TING BUILDING HAS NO FIRE 5PRINKLER5 AND 15 OF A55UMED TYPE 513 CON5TRUCTION. THE BUILDING 15 HEATED BY A GA5 FORCED AIR FURNACE 5Y5TEM. APPLICATION OF I.E.S.G. REOUIRMENTS PER IEBC CHAPTER 3, TH15 PROJECT 15 FOR A CHANGE OF OCCUPANCY. PER IEBC 301.3.1, CHANGES OF OCCUPANCY MEETING IEBC CHAPTER 5 AND IFC ARE COMPLIANT. PER IEBC 302.3, OCCUPANCY CHANGES MUST MEET IBC, WITH IEBC TAKING PRECEDENT. WORK 15 PROP05ED UNDER IEBC CHAPTER 5 - PRESCRIPTIVE COMPLIANCE METHOD. THE EX15TING BUILDING ARRANGEMENT WITH THE PROP05ED CHANGE OF OCCUPANCY MEETS CURRENT IBC LIFE SAFETY REQUIREMENTS. 5EE CODE AND EXITING PLAN5 ON TH15 SHEET. PER IEBC 305.1, NO UPGRADE5 TO ACCE55113ILTY ARE PROP05ED OR REQUIRED. NO UPGRADES TO ELECTRICAL, MECHANICAL, OR ALARM 5Y5TEM5 ARE PROP05ED OR REQUIRED. APPLICATION OF I.S.G. REOUIRMENTS CLASSIFICATION OF PROPOSED OCCUPANCIES (PER IBC SECTION 302 AND TABLE 1004.5) PROJECT NAME: EDMOND5 CO-OP PRE5CHOOL INTO EDMOND5 PRE55YTERIAN CHURCH. PROJECT U5E5: A-3 A55EM13LY WITH NON -SEPARATED E USE. BUILDING AREA = 5990 5F BUILDING HEIGHT= ONE 5TORY, LE55 THAN 40' ALLOWABLE AREA PER IBC 5ECTION 504 t TABLE 504.3 USE CON5T TYPE 5PRINKLERED AREA ALLOWED A-3 513 NO G,000 E 513 NO 9,500 TH15 PROJECT COMPLIES WITH BOTH AREA LIMITS. ALLOWABLE AREA INCREASES NO AREA INCREASES ARE PROPOSED. ALLOWABLE HEIGHT $ STORIES PER IBC 5ECTION5 503; TABLE 504.3 * TABLE 504.4 USE CON5T TYPE HEIGHT IN FEET STORIES A-3 5B 40 ONE E 5B 40 ONE TH15 PROJECT COMPLIES WITH BOTH AREA LIMITS. ALLOWABLE HEIGHT INCREASES NO HEIGHT INCREASES PROP05ED MIXE7 OCCUPANCIES ANALYSIS PER IBC SECTION 508.3 NEW BUILDING CONFIGURATION CONTAINS MORE THAN ONE OCCUPANCY TYPE. AREA OF MIXED OCCUPANCIES: A-3 = 5049 5F E = 551 5F BOTH AREAS ARE LE55 THAN LIMITS OF TABLE 503, THEREFORE U5E NON-5EPARATED OCCUPANCIES. OCCUPANCY SEPARATIONS REQUIRED PER IBC TABLE 508.4 A-3 TO E = NO 5EPARATION REQUIRED 1 1 /3/2023 10: 1 5:55 AM IF THI5 GRAPHIC DOE5 NOT MEA5URE 2" 7 I1E DRAWING HA5 BEEN SCALED. 0 I 2 I 12404 REGISTERED ARCHITECT BRYAN H. SCHUTT STATE OF WASHINGTON ALL RIGHTS RESERVED BY BRYAN 5CHU77, ARCHITECT © DO NOT REPRODUCE WITHOUT 5FECIFIC PERMISSION BRYAN SCHUTT ARCHITECT Phone: 406.250A'165 www.BRYANSCHUTTARCH ITE:CT.com CHANGE OF USE APPLICATION FOR E;MON75 X -OP PRESCHOOL AT E7MON75 FRESBYTERIAN CHURCH 22600 g671­1 AYEUNE WEST E7MON75, WA Q5020 BUILDING GONE ANALYSIS Revisions: SUBMIT FOR BLDG. PERMIT Date: NOV 5, 2025 ro W W EXISTING SCREENED TRASH AREA PARCEL #005075500000501 1.55 ACRES 1 1 SITE PLAN A100% 1" = 20'0° 560 5F TOTAL PARCEL #00515500000500 1.5 ACRES W W S A100 SHEET NOTES I NEW FIRE LANE STRIPING PER EDMOND5 STANDARDS. APPX 550 L.F. SEE DETAIL TI115 PAGE. 2 NEW FIRE LANE STENCILS PER EDMOND5 STANDARDS. APPX I I TOTAL SEE DETAIL THIS PAGE. LETTERING STANI7ARPS PAVEMENT FIRE LANE LETTERING SHALL MEET THE FOLLOWING STANDARDS: I - PAVEMENT STENCIL SHALL BE A MINIMUM OF 12 INCHES TALL, YELLOW, "FIRE LANE - NO PARKING" WITH THICK FONT LETTERING FOR CLEAR AND EASY READING. 2 - PAVEMENT STENCIL SHALL BE P051TIONED A5 TO BE LEGIBLE FROM THE FIRE LANE 51DE OF THE FIRE LANE STRIPPING AND PLACED PARALLEL TO THE FIRE LANE STRIPPING. 3 - PAVEMENT STENCIL SHALL BE SPACED EVERY 30' FEET AND ALTERNATE WITH THE OPP051TE 51DE OF FIRE LANE LETTERING. z Y Q a Q z I W z W m Ir J Q D c� E w E' o Q Ln Ln 12" MIN w A 2" STROKE m z PAINTED m STRIPING Z a a z c� 20' MIN 0(D NOTES: 4" PERIMETER STRIPING (TO BE 5" OFFSET FROM CURB OR EDGE OF PAVEMENT PARKING ANY TIME FI RE LANE Z W 0 Q w 0 W 0 m Q a cb I co lqt THE USE OF SIGNS REQUIRES FIRE MARSHAL APPROVAL 1O FIRE LANE MUST MEET ALL MINIMUM CITY OF EDMONDS DRIVEWAY/ACCESS STANDARDS AND SOUTH SNOHOMISH COUNTY REGIONAL FIRE AUTHORITY'S (SSCRFA) FIRE LANE STANDARD. �2 FIRE LANE SHALL MAINTAIN AN UNOBSTRUCTED MINIMUM WIDTH OF 20' UNLESS APPROVED BY THE FIRE MARSHAL. FIRE LANE TO BE ASPHALT OR APPROVED EQUIVALENT. FIRE LANE SHALL MAINTAIN AN UNOBSTRUCTED MINIMUM VERTICAL CLEARANCE OF 13.5'. FIRE LANE SHALL NOT HAVE A GRADE EXCEEDING 12% UNLESS APPROVED BY SSCRFA. PAINTED STRIPING SHALL BE YELLOW IN COLOR. REFER ALSO TO CITY OF EDMONDS AND SSCRFA FIRE LANE STANDARD FOR CIRCULATION AND TURN-AROUNDS. REVISION DATE CITY OF EDMONDS FIRE LANE SPECIFICATIONS JANUARY 2018 (MULTI -FAMILY AND PUBLIC WORKS COMMERCIAL) STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH I T R- 5 6 7 EGP STRIPING DETAIL 7R-561 1 1 /3/2023 1 0: 1 5:55 AM L IF TH15 GRAPHIC DOE5 NOT MEA5URE 2" THE DRAMNG HAS BEEN SCALED. O 1 2 1 a I 12404 REGISTERED ARCHITECT 63 BRYAN H. SCHUTT I STATE OF WASHINGTON ALL RIGHTS RE5ER\/W BY BRYAN 5CHUTT, ARCHITECT © DO NOT REFROWCE WITHOUT SPEGFIC PERMISSION BRYAN SGHUTT ARCHITECT Phone: 406.280.Fg63 www.BRYANSCHUTTARCH ITECT.co m CHANGE OF USE APPLICATION FOR VYCN;S GO -OF FRESCHOOL AT EDMOND5 FREBBYTERIAN CHURCH 22600 %TH AVEUNE WEBT EDMOND5, WiA g5020 51Tl FLAN A100 Reviai0na: SUBMIT FOR BLDG. PERMIT Date: NOS/ 5, 2025 1 1 /3/2023 10: 1 5:55 AM I FLOOR PLAN N O♦F5 L F T 15 GRAFIN DOES NOT MEASURE 2 TI1E DRAWING 11A5 BEEN SCALED. 1 2 3 4 O I 2 PROJECT IS A CHANGE Of USE ANALYSIS FOR A RELOCATED PRE-SCHOOL INTO TO PARKING LOT AN EXISTING CHURCH. 12404 REGISTERED 20'-811 30'-31' 411-G11 1. ALL DOORS WITHIN THIS SPACE ARE 3G" WIDE OR A PAIR Of 3G" WIDE DOORS.ZSTATE ARCHITECT 201-711 9'- 1011 201-711 101-311 101-311 2. ALL DIMENSIONS ARE ACCURATE TO G" RYAN H. SCHUTT ® ® — - 3. NO CHANGES TO BUILDING ENVELOPE, ELECTRICAL, OR MECHANICAL SYSTEMS ARE PROPOSED. OF WASHINGTON I I I = I PORCH OPEN CID GR�7E1 s O C) O O O O ODD� a -�NoKITCHEN PASTOR 0 OFFICE N ' SANCTU RY 151-511 5'-1 11 / Q1-311 4 5EAT5 4 SEATS -_ Ln Ln 6 SEAT5 TYF. . tv C'n CV — — O Y _ 5 N TU 1 I TH 1 �' SEATI - N OPE COURT / GLASS 1 ALL RIGHTS RESEED RVBRYAN SCHUTT, ARCHITECT HOUT SPEOIPIG PERMISSION ©DO NOT REPRODUCE WITHOUT FELLONSHIP HAL U-i FEM 0 o BRYAN SCHUTT ARCHITECT Phone: 406.250A'165 N www.BRYANSGHUTTARCH ITEGT.ccm - GHNGE OF USE _ APPLICATION FOR E;YCN;B GO -OF PRESCHOOL ' — ,, - - o c\j AT EDMOND5 FRESBYTERIAN CHURCH STORE -STORE CLASS 2, 22600 g671­1 aYEUNE WEST EDMOND5, WAS Q5020 STORE EXI5TINC FLOOR PLAN Ln 1 01- 1 11 1 0'-211 301-511 51-011 51-811 9'- I OII 201-911 A200 921-011 OVERALL Reviaiom SUBMIT FOR BLDG. PERMIT K'5 EXIBTINS FLOOR PLAN Date: NO\/ 5, 2025 1 1 /3/2023 10: 1 5:55 AM IP THIS GRAPHIC DOE5 NOT MEA5URE 2" 0 THE DRAWINI G HAS BEEN SCALED. 2 S EN ERAL L I S H T I N S NOTES 1. TH15 PROJECT IS A CHANGE Of U5E ONLY AND PROP05E5 NO CHANGE5 TO EXISTING LIGHTING. 12404 2. LIGHTING IN MAIN ROOMS 15 5HOWN HERE. LIGHT FIXTURE5 IN STORAGE AND MECHANICAL ROOMS ARE NOT 5HOWN. 3. SEE W5EC LIGHTING COMPLIANCE PAGE ON TH15 SHEET. UOFWASHINGTO LIGHTING LEGEND I x4 FLUORESCENT PORCH OPEN - SAR17EN TWIN SPOTLIGHTS O CEILING MOUNTED GLOBE O 00 o 1 0000 ► O Fr-) O WALL SCONCE O O� 0 P TOR oKITCHEN EN RY OFFICE WALL-MTND LIGHT BARM RR__ W RR WALL LIGHT SANC VARY \ - EXIT SIGN WALL MOUNTED ,' , OPEN PACE O O MotorRequirements .. 0=&o 0=" 2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by @2023 NEEA, All rights reserved The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the Washington State Energy Code, Commercial Provisions. OFFICE For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com _ Project: 0 ECP Change of Use - 2018 WSEC EDMONDS PRESBYTERIAN CHURCH 22600 96TH AVEUNE WEST Edmonds, WA 98020 Date: 2023-11-02 Applies Code Section Component Compliance Information Required In Permit Location in Building Department All R*HTS RESERVW BY BRYAN 5CHU77, ARCHITECT © REFROMCI SFE IFIC PERMISSION — — — — — — Documentation Documents Notes GO NOT kNITHOUT LIGHTING SCOPE ' NA C 103.1 Construction For a shell & core or tenant space (first build - documents - General out) project, indicate if there is no fighting SANCTUARY YNITH included in scope the project. g FOM F IXE17 SEATING OPEN COURT LASS 1 YES C103.1 Construction For an alteration project, indicate if there is G100 FELLOWSHIPHA documents - General no lighting scope included in the project. O LIGHTING CONTROLS NA C405.2 Lighting controls, For all lighting fixtures, indicate lighting general control method on plans for spaces and 5 R'AN S C H U TT - lighting zones) served, or exception taken C405.2, Luminaire level Indicate on plans all fixtures provided with ARCHITECT _ Option 2 lighting controls LLLC in lieu of C405.2 lighting controls; (LLLC) provide description of control capabilities and performance parameters Phone: 406.250.9g63 C405.2.5, Lighting in dwelling Indicate method of automatic control of all www.5RYftN5GHUTTARCH ITEGT.eom Item 3 units (dormitory, installed luminaires in dwelling units in CHAN CG E OF USE LJ C405.2.1.1 hotel and all other buildings other than multifamily (occupancy C405.2.3.1 than multifamily) or light reduction controls) C405.2.5, Lighting in sleeping Indicate method of automatic off control of Item 2 units all installed luminaires in sleeping units �PPLIG�TION (vacancy or key card control); also refer to Receptacles FOR - C405.2.3 Manual controls Indicate on plans the method of manual EnMON;S GO -OP PRESCHOOL - - _ C405.2.3.1 lighting control, location of manual control C405.2.5 device and the area or specific application it V 0 0 serves AT C405.2.3.1 Manual interior light Indicate on plans which method of manual EDMONDS PRESBYTERIAN CHURCH C405.2.1.1 reduction controls 50% lighting load reduction is provided, or 22600 %TH A \/EUNE WEST C405.2.4 indicate applicable exception EDMOND5, WAA Q5020 C405.2.1 Method of automatic Indicate on plans the method of automatic C405.2.2.1 shut-off control shut-off control during unoccupied periods TOE STORE GLASS 2 C405.2.1, (occupancy sensor, time switch or digital Exception 3 for lighting timer switch) all zones LIGHTING FLAN C405.2.1 Occupant sensor Indicate on plans all luminaires that are S GE controls controlled by occupant sensor controls; STORE o o 1 configured s are � gored to turn es M EGH luminaires 100 luminaires 100% off when the space is unoccupied C405.21 Occupant sensor Indicate if occupant sensor controls are C405.2.1.1 controls configured to be manual on or automatic on to not more than 50% power; indicate spaces eligible for exception that allows automatic on A20 1 to 100% power Page 1/10 Revisions: SUBMIT FOR 150G. PERMIT FN� ELECTRICAL LIGHTING BACKSROUNP ECP WSEC LIGHTING PASE 201 5/16" = V-0" Date: NOV 5, 2025