BLD2024-0192_Site_Plan_3.22.2024_10.33.29_AM_4151229Equipment Summary
Modules:
(45) REC 410w Alpha BoB
Inverter(s):
(45) Enphase IQ8M (240V)
Racking:
Ironridge XR100 Tilt Kit/
U-Anchor 2400
Table of Contents:
Cover Page
Al Site Overview
A2 Roof Layout
A4 Racking
E1 Single Line
E2 Electrical Calculations
G1 Roof As Built
G1.1 Enphase Branching
G2 Electrician As -Built
G3 Micro/optimizer map
G4 Placards
G5 Equipment BOM
General Notes:
Additional Work:
-Tesla wall connector 60A <6 ft. of MSP
RECEIVED
Mar 26 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2024-0192
df
AP
. AI
�.
116
Site
77
F�
N _
oo"
1
Im"
® �
A&RSOLAR
3211 Martin Luther King Jr Way S.
handes h o'
reviev
not in
of woi
Statio
x
rT� — ] _I_J—Net Meter
_ I ,
ed and
C R ANY RIGHT I OR L CENSE OEUSE T
OR THE INFORMATION DISCLOSED HEREIN
H E/WE NY PAENO CE HIS AR
SOLART
a
M
�
�
o
00
E
N
o
�Ma-'�
r�
Ln
U
Eo
ru
wQ
,�
._
VD
vi
-a
^�
Porn
o
O
E
L.Ln
a;:j:
_0
w
CID
REVISIONS
Rev. #: Date:
1 3/22/24
Designed by: Tyler M.
Project Manager:
Will MacArthur
(206)307-1741
Current Date:Mar 22, 2024
Cover Page
PV Module(s)
-200A MSP
-Unprotected Loads
Panel
-Combiner Box(Battery)
-Tesla Powerwall(x2)
-Testa wall connector
-Net meter
-Testa Gateway
-Combiner Box(Pv)
-AC Disconnect(Pv)
-AC Disconnect
(Battery)
Attachment Detail
SIDE VIEW (PORTRAIT
TILT KIT
RA(llTNr. A ATTArHMF
ROOF DECK
MEMBRANE ROOF
DENSDECK OR COVERBOARD
(OPTIONAL)
INSULATION ASSEMBLY
(OPTIONAL)
ROOF DECK
4NCHOR
00
HOT AIR
WELD
�14
JCTURAL
FENERS
Rafters or Manufactured trusses, 24"
O.C.
(sample) Attachment point layout for array.
48" OC Max.
b
N
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
U
a
ELn
N
Mimi
" U
O�
O
L. Ln
a11:1:
co
,--I
O
N
M O
00
- M 4-+ ON
ro Ln U)
Eow<
ru C
U)
oiO�-�
Y o 0, o
�• E
LU
REVISIONS
Rev. #: Date:
1 3/88/24
Designed by: Tyler M.
Project Manager:
Will MacArthur
(206)307-1741
Current Date:Mar 22, 2024
Al Site
Overview
Required Setbacks from Ridge:
N/A
Max. Mount Spacing: Portrait/Landscape
48"/48"
Roof Type:
TPO
Roof Slope:
00
Array Tilt :
150
Array Azimuth(s):
1800
Roof Area:
1913 ft2
Array Area
896 ft2
Array to Roof Coverage
46%
***Roof Attachments/ Fastners: see pg. G5 Equip, BOM * * *
Module and Rail Selection Guide
(45) REC410AA Pure
40 x 71.7
Mount: U-Anchor 2400
Clamp Zone "A"
7.9-11.8"
Clamp Zone "B"
14.8-19.9"
Mods per Row
Rail typel+ rail type2
(1)Row, (9)Portrait
(4)17'
a
(1)Row, (7)Portrait
(4)14'
b
(5)Rows, (5)Portrait
(2)14' (2) split 14'
C
(1)Row, (4)Portrait
(2)17'
d
e- 1-*
b
282 1/4" ►
IFC 605.11.1 Exception for pathway requirements,
If less than 2:12 pitch
Net Meter
S, l Y�A,
JQ��4
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
U
a
�
�
o
00
E
fV
�Ma—'�
(O
In
U
Eo
ru
�Q
VD
o-a
vi
^�
1
0
o
O
E
L.
a;:1-
In
w
co
REVISIONS
Rev. #: IDate:
Designed by: Tyler M.
Project Manager:
Will MacArthur
(206)307-1741
Current Date:Jan 29. 2024
A2 Roof Layout
SIDE VIEW (PORTRAIT
TILT KIT
PV MODULE
RACKIN(
u1:1u1 W-110: z•1•12
DENSDECK OR COVERBOARD
(OPTIONAL)
INSULATION ASSEMBLY
(OPTIONAL)
48"
Net Meter
m�1
ROOF DECK
M
15° N
36" I ROOF DECK
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
ANCHOR
THIS DRAWING CONSTITUTES THE
00
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
HOT AIR
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
WELD
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
�f14
U CTU RAL
rENERS
U
a
M
�
�
o
00
E
N
�Ma-'�
ro
Ln
U
Eo
ru
wQ
,�
._
Vp
ova'
vi
-a
^�
1
0
o
O
E
L.
a":1:
Ln
w
co
,--I
REVISIONS
Rev. #: I Date:
Designed by: Tyler M.
Project Manager:
Will MacArthur
(206)307-1741
Current Date:Feb 12, 2024
A4 Racking
PV Single Line
String 1
11 modules
String 2
10 modules
String 3
9 modules
String 4
8 modules
String 5
7 modules
0 EEquipment Schedule
IN
u
A
u
A
u
Generation Panel
Bus: 125A
Location: Exterior
Ref.
Category
Equipment
QTY
1
Modules
REC410AA Pure
45
2
Inverters
Enphase IQ8M-72-M-US
45
3
Jbox
JBox
2
4
Loadcenters
MLO, 125A, 240V, 1ph, Nema 3R, Surface, 12 space (min.)
1
5
Disconnect
100A 600V 2 Pole I Heavy Duty, No Fuse, Lockable
1
Breakers
2p20A
5
Monitoring
Enphase IQ Monitoring
1
Misc.
Enclosure for IQ Gateway NEMA 3
1
0 Conductor Schedule
nverter Specs
Watts
u
Output
AC
Voltage
#of
Inverters
OCPD
Branch
ll
Enphase IQ8M-72-M-US
325
1.35
240
45
20
****N/A****
0
0
0
0
0
****N/A****
0
0
0
0
0
Module Specs
Watts w
Imp
vmp
voc
Isc
REC410AA Pure
410
9.61
42.7
49
10.35
Temp. Adjusted
0
0
38.9
52.8
0
Summary
Distance
(ft)
Current
@125%
Operating
Voltage
Voltage
Drop
V. Drop
(total)
A
(2)#12 CU, (1)#6 EGC, Q Cable, AIR
46.2
18.56A
240V
0.62%
1.85%
B
(2)#12 CU, (1)#10 EGC, QCable, AIR
6
18.56A
240V
0.15%
C
(6)#10 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min)
25
18.56A
240V
0.38%
D
(4)#10 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min)
35
13.5A
240V
0.39%
E
(2)#4 CU, (1)#8 N, (1)#8 EGC, THWN-2, 1"EMT(min)
10
75.94A
240V
0.16%
F
(2)#4 CU, (1)#8 N, (1)#8 EGC, THWN-2, 1"EMT(min)
10
75.94A
240V
0.16%
Storage Single Line
F
0 Equipment Schedule
A
Bus Rating: 100A v^
Loads: 50A EV Charoer
Ref.
Category
Equipment
QTY
1
Gateway
Tesla Backup Gateway2: Service Rated
1
Breakers
200A Main Breaker (Eaton CSR2200N)
1
Misc.
Tesla 200A Internal Panelboad Kit
1
Breakers
2p80A, 2p60A
2
Battery
Tesla Powerwall 2, 13.5 kWh
2
Misc.
Powerwall Stack Kit
1
3
Loadcenters
MLO, 125A, 240V, 1ph, Nema 3R, Surface, 4 space (min.)
1
Breakers
2p30A, 2p30A
4
Disconnect
60A 600V 2 Pole I Heavy Duty, No Fuse, Lockable
1
5
LoadCenters
MLO, 100A, 240V, 1ph, Nema 1, Flush, 8 space (min.)
1
Breakers
2p100A
1
0 Conductor Schedule
Service entrance conductors
4/0 XHHW-2
(L1 & L2)
2/0 XHHW-2
TESLA Gateway2 (N)
200A Internal Panelboard
Solar OCPD:80A
Battery OCPD:30A
Battery OCPD:30A
Circuit to Non backed up
loads 100A max
Net Meter
i4-
4/0 XHHW-2
(L1 & L2)
OOA/2p 2/0 XHHW-2
(N)
#6 THWN-2
(EGC)
Protected Loads Panel
(Existing)
Main Service Panel
(1ph 240V Service)
Main Breaker: 200A
Bus Rating:200A
i
= A & R Scope
= Existing or A&RSOLAR
Others Scope
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
Inverter Specs
Watts
Output
AC
Voltage
# of
Inverters
OCPD
LAI
J�d
Tesla Powerwall 2
5000
1 24
240
2
30
Summary
Distance
(ft)
Current
@125%
Operating
Voltage
Voltage
Drop
V. Drop
(total)
A
(4)#10 CU, (2)#10 N, (1)#10 EGC, THWN-2, & com wire, 1"EMT(min)
10
30A
240V
0.25%
0.45%
B
(2)#6 CU, (1)#6 N, (1)#10 EGC, THWN-2, & com wire, 1"EMT(min)
10
60A
240V
0.20%
General Notes:
Utility: SnoPUD
1. EGC Where exposed to physical damage will be
#6AWG Bare CU
2. If installing conduit on the roof, maintain greater than
7/8" above the surface
3. NEC 690.12: Rapid Shutdown initiated by AC
Disconnect
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
:ONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
r�
Q
O
co
c�M��
M
O
E�
c�N�
p
�L�'
a
� U
ro
(6
O
rl
Vow
0
v7
�e
"D
O
O
■^
O
O
E
L
Ln N
70
LU
a�
00
REVISIONS
Rev. #: Date:
1 3/15/24
Designed by: Tyler M.
Project Manager:
Will MacArthur
(206)307-1741
Current Date:Mar 15, 2024
E1 Single Line
Inverter Specs
Enphase IQ8M-72-M-US
****NSA****
****NSA****
Module Specs
REC410AA Pure
Temp. Adjusted
MLPE or RSD?
Equipment
Mppt Input
Module
# Modules per String
# Strings
# of Mods per group
# of Mods/inverter
# of Inverters
Total # of Modules
PV Electrical Calculations
Watts Output # of OCPD Total AC Comb. EGC
AC Voltage Array Specs (Adjusted for Temaerature
IWI
ll
Inverters
Branch
out.(A)
OCPD
AC
325
1.35
240
45
20
60.8
80
#8
1 nverter
0
0.00
0
0
0
Mppt Input
0
0.00
0
0
0
Amperage (Imp)
W(a-t)ts
IMPVVm
Voc
Isc
Temp. Coef V(oc)
(DC)
Voltage (Vmp)
410
9.61
42.7
49
10.35
Max Voltage(DC)
-0.24 #10
38.9 52.8 Max Amps (DC)
***Select***
Enphase IQ8M-72-M-US
Enphase IQ8M-72-M-US
Enphase IQ8M-72-M-U
1
2
3
4
1
2
3
4
1
2
3
REC410AA Pure
REC410AA Pure
REC410AA Pure
1
0
0
0
1
0
0
0
1
0
0
1
0
0
0
1
0
0
0
1
0
0
1
0
0
0
1
0
0
0
1
0
0
1
1
1
11
8
26
45
Enphase IQ8M-72-M-US
Enphase IQ8M-72-M-US
Enphase IQ8M-72-M-US
1
2
3
1
2
3
1
2
3
9.61
0.00
0.00
9.61
0.00
0.00
9.61
0.00
0.00
38.9
0.0
0.0
38.9
0.0
0.0
38.9
0.0
0.0
52.8
0.0
0.0
52.8
0.0
0.0
52.8
0.0
0.0
10.35
0.00
0.00
10.35
0.00
0.00
10.35
0.00
0.00
s
4
Max Array Power(STQ 18.45kW DC
Max Continuous AC Power: 14.625kW AC
Interconnection Calcs
Main Breaker
200
Bus Bar
200
Max PV OCD Allowed
40
PVOCPD Device Used
80
Tap or Breaker?
Breaker
Site Conditions
ASHRAE Site:
Seattle
Low Temp (°F)
19
High 2%Temp (°F)
84
High 0.4%Temp (°F)
91
Ref.
Conductor Description
Distance
AL CU
Wire
Gauge
QTY Phase
Neutral
Neutral
EGC
(AWE)
Wire Type
Conduit
Min.
Conduit
90°C
Rating
Temp
Correct.
Fill
Derate
Derated
75°C
Rating
Current
Operating
Voltage Drop
ft
Conductors
AWe
QTY
Type
Ampacity
125%
I Voltage
A
Microinverter Branch
46.2
CU
#12
2
N/A
N/A
#6
QCable
AIR
N/A
30
1
100%
30.00
25
18.6
240
0.62%
B
Branch to Jbox
6
CU
#12
2
N/A
N/A
#10
QCable
AIR
N/A
30
1
100%
30.00
25
18.6
240
0.15%
C
Jbox1 to Combiner
25
CU
#10
6
#8
1
#10
THWN-2
EMT
0.75"
40
1
80%
32.00
35
18.6
240
0.38%
D
Jbox2 to Combiner
35
CU
#10
4
#8
1
#10
THWN-2
EMT
0.75"
40
1
80%
32.00
35
13.5
240
0.39%
E
Combiner to Disco.
10
CU
#4
2
#8
1
#8
THWN-2
EMT
1"
95
1
100%
95.00
85
75.9
240
0.16%
F
Disco. To Interconnect
10
CU
#4
2
#8
1
#8
THWN-2
EMT
1"
95
1
100%
95.00
85
75.9
240
0.16%
G
H
I
J
DC Voltage Drop 0.00% AC Voltage Drop 1.85% Total Voltage Drop 1.85%
&ffl.
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
U
Ma
O
�
M
O
Ln
00
E
N
-0
M
��
rru
Ln
U
Eo>Q
Ln
G�
>C)
0
O
o
.O
�
E
L.
Ln
a�
w
co
REVISIONS
Rev. #: Date:
1 1 3/15/24
Designed by: Tyler M.
Project Manager:
Will MacArthur
(206)307-1741
Current Date:Mar 15, 2024
E2 Electrical
Calculations
Typical Placards
Custom Placards
A) NEC 2020 690.13 & 691.15
B) NEC 2020 705.12 (13)(3)(2)
C) Utility Requirement
D) Utility Requirement (Utility -Owned)
D) A&R Solar Requirement (Customer -
Owned)
E) A&R Solar Requirement * if combiner used
F) NEC 2020 690.13 (B)
I) NEC 2020 690.31 (D)(2)
K) NEC 2020 690.13 (B)
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SOLAR ELECTRIC
PV PANELS
SHUTDOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD IN THE
ARRAY
L) NEC 2020 690.56 (C)
Located on or no more than 3' from the
service disconnecting means to which the PV
system is connected
O) A&R Solar Requirement * if
multiple inverters
IAWARNING DUAL POWER SOURCEI
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
P) NEC 2020 705.12(C) & 690.59
IF
` • D• NOT INSTALL
ADDITIONAL LOADS IN THIS PANEL
R) AHJ Requirement * if combiner used
S) NEC 2020 230.85(1)
T) NEC 2020 230.85(3)
PLACARD SPECS
G) NEC 690.54
MAX AC OUTPUT CURRENT: 14.85 A AC
OPERATING AC VOLTAGE: 240 V AC
Letter Height: 1/8"
Maintain 1/4" border
Red / White
G) NEC 690.54
MAX AC OUTPUT CURRENT: 13.50 A AC
OPERATING AC VOLTAGE: 240 V AC
MAX AC OUTPUT CURRENT: 12.15 A AC
OPERATING AC VOLTAGE: 240 V AC ... -
G) NEC 690.54
MAX AC OUTPUT CURRENT: 10.80 A AC
OPERATING AC VOLTAGE: 240 V AC -
MAX AC OUTPUT CURRENT: 9.45 A AC
OPERATING AC VOLTAGE: 240 V AC
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
� OR THE INFORMATION DISCLOSED HEREIN
Q I I/ NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
3
Branch of 11
(1) for each PV load
center,
Disconnect,
MSP/uostrea m
1 Branch of 10
1 Branch of 9
1 Branch of 8
1
5
M Ln
E N
O
L. Ln
la
Co
N
M O
00
- M 4-+ ON
ro Ln U)
E p w Q
fu ,--I .0
U)
oiOC
Y ON M O
.� E
W
Branch of 7 REVISIONS
Rev. #: Date:
1 3/15/24
Designed by: Tyler M.
Project Manager:
Will MacArthur
(206)307-1741
Current Date:Mar 15, 2024
G4 Placards
J) NEC 2020 690.56 (C)(2)
Standard Storage Placards
Label Location:
(BLC)
Label Location:
(GP)
Label Location:
(BLC)
Label Location:
(BLC,MSP,NM)
NEC 705.12(C)
For storage only
projects
Label Location:
(TG if outside,
service disconnect
breaker if TG
is inside)
NEC 230.85
BLC - Backup Load Center
GP - Generation Panel
MSP - Main Service Panel
NM - Net Meter
TG - Tesla Gateway
Label Location:
(BLC,MSP,NM)
NEC 705.12(C)
For PV+storage
projects
Label Location:
(BLC)
NEC 705.12(B)(3)(3)
Label Location:
(TG)
Label Location:
(GP)
Label Location:
(Battery breaker or
battery disconnect)
NEC 706.15(C)
Custom Storage Placards &*41.IPA�
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
CAUTION:
POWER TO THIS SERVICE IS ALSO SUPPLIED FROM SOLAR PV AND ENERGY
STORAGE SYSTEM SOURCES WITH DISCONNECTS LOCATED AS SHOWN:
PV I
N
PINE ST.
Directory Placard Qty. 1
THIS DRAWING CONSTITUTES THE
CONFFIDENTIAL INFORMATION OFA&R SOLAR
AND ITS RECEPTOR POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATTION DISCLOSED HERE IN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HERE IN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
M
N
O
('M
O
G)
O
-0
M
�
M
(%
ra
Ln
U
Ec
�
ro
'0-1
O
Y
O
p�
.r,
O
N
.�
0
0
L
N
w
a
AY(S) REVISIONS
Rev. #: I Date:
SOLAR AND
BATTERY AC
DISCONNECTS
NET METER
Designed by: Tyler M.
PM: Will MacArthur
(206)307-1741
Current Date:Jan 29, 2024
PV-G3 Placards
&*41.
A&RSOLAR
3211 Martin Luther King Jr Way S.
Seattle, WA 98144 (206)707-9937
THIS DRAWING CONSTITUTES THE
CONFIDENTIAL INFORMATION OF A&R SOLAR
AND ITS RECEPTOR. POSSESSION DOES NOT
CONFER ANY RIGHT IN OR LICENSE TO USE IT
OR THE INFORMATION DISCLOSED HEREIN
NOR ANY RIGHT TO REPRODUCE THIS
DRAWING OR ANY PART HEREIN WITHOUT
THE WRITTEN CONSENT OF A&R SOLAR.
a
e
M Ln
E N
>�
+U
Vp
^�
O
L.Ln
a�
00
0
00
-0 M 4- ON
r0 Ln (n
Eo �Q
ru
��a vi
ova' -a
1om o
E
_0
w
REVISIONS
Rev. #:
Date:
Designed by: Tyler M.
Will MacArthur
(206)307-1741
Current Date:Mar 22, 2024
G5 Equipment
BOM
Category
Equipment
QTY
Notes
Modules
REC410AA Pure
45
Inverters
Enphase IQ8M-72-M-US
45
Jbox
JBox
2
Loadcenters
MLO, 125A, 240V, 1ph, Nema 3R, Surface, 12 space (min.)
1
Disconnect
100A BOON 2 Pole � Heavy Duty, No Fuse, Lockable
1
Breakers
2p20A
5
Monitoring
Enphase IQ Monitoring
1
Misc.
Enclosure for IQ Gateway NEMA 3
1
ElectricalWork
Tesla Wall Charger Install (wired to 60A breaker)
1
Breakers
2p60A
1
EV charger
Breakers
2p20A
1
Breaker for IQ Gateway
Enphase accessories
Misc.
Portrait Q cable
47
Enphase Q Cable Q-12-10-240
Misc.
Terminator Caps
7
Q-TERM-10
Misc.
Male Q Connector
11
Q-CONN-10M
Misc.
Female Q Connector
9
Q-CONN-10F
IronRidge Racking BOM
XR100 Black,l7'
6
XR100 Black,l4'
19
Kit, XR100 Bonded Splice BOSS
14
Universal Module Clamp, Black
106
Stopper Sleeve 30mm
32
Grounding Lug, Low Profile
8
Square -Bolt Bonding Attachment Hardware
97
1/4 x 3/4 Microinverter Bonding Hardware, T-Bolt
45
End Caps, 10 sets(package) XR100
2
U-Anchor 2400, Mill (Spacing: 48")
97
Fastener: #14 x 2-8" DF-#14 PH3 (8 /mount)
776
3/8-16 flange nut
97
15" Tilt Leg Kits
49