BLD2024-0192_Site_Plan_3.22.2024_10.33.29_AM_4151229Equipment Summary Modules: (45) REC 410w Alpha BoB Inverter(s): (45) Enphase IQ8M (240V) Racking: Ironridge XR100 Tilt Kit/ U-Anchor 2400 Table of Contents: Cover Page Al Site Overview A2 Roof Layout A4 Racking E1 Single Line E2 Electrical Calculations G1 Roof As Built G1.1 Enphase Branching G2 Electrician As -Built G3 Micro/optimizer map G4 Placards G5 Equipment BOM General Notes: Additional Work: -Tesla wall connector 60A <6 ft. of MSP RECEIVED Mar 26 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2024-0192 df AP . AI �. 116 Site 77 F� N _ oo" 1 Im" ® � A&RSOLAR 3211 Martin Luther King Jr Way S. handes h o' reviev not in of woi Statio x rT� — ] _I_J—Net Meter _ I , ed and C R ANY RIGHT I OR L CENSE OEUSE T OR THE INFORMATION DISCLOSED HEREIN H E/WE NY PAENO CE HIS AR SOLART a M � � o 00 E N o �Ma-'� r� Ln U Eo ru wQ ,� ._ VD vi -a ^� Porn o O E L.Ln a;:j: _0 w CID REVISIONS Rev. #: Date: 1 3/22/24 Designed by: Tyler M. Project Manager: Will MacArthur (206)307-1741 Current Date:Mar 22, 2024 Cover Page PV Module(s) -200A MSP -Unprotected Loads Panel -Combiner Box(Battery) -Tesla Powerwall(x2) -Testa wall connector -Net meter -Testa Gateway -Combiner Box(Pv) -AC Disconnect(Pv) -AC Disconnect (Battery) Attachment Detail SIDE VIEW (PORTRAIT TILT KIT RA(llTNr. A ATTArHMF ROOF DECK MEMBRANE ROOF DENSDECK OR COVERBOARD (OPTIONAL) INSULATION ASSEMBLY (OPTIONAL) ROOF DECK 4NCHOR 00 HOT AIR WELD �14 JCTURAL FENERS Rafters or Manufactured trusses, 24" O.C. (sample) Attachment point layout for array. 48" OC Max. b N A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U a ELn N Mimi " U O� O L. Ln a11:1: co ,--I O N M O 00 - M 4-+ ON ro Ln U) Eow< ru C U) oiO�-� Y o 0, o �• E LU REVISIONS Rev. #: Date: 1 3/88/24 Designed by: Tyler M. Project Manager: Will MacArthur (206)307-1741 Current Date:Mar 22, 2024 Al Site Overview Required Setbacks from Ridge: N/A Max. Mount Spacing: Portrait/Landscape 48"/48" Roof Type: TPO Roof Slope: 00 Array Tilt : 150 Array Azimuth(s): 1800 Roof Area: 1913 ft2 Array Area 896 ft2 Array to Roof Coverage 46% ***Roof Attachments/ Fastners: see pg. G5 Equip, BOM * * * Module and Rail Selection Guide (45) REC410AA Pure 40 x 71.7 Mount: U-Anchor 2400 Clamp Zone "A" 7.9-11.8" Clamp Zone "B" 14.8-19.9" Mods per Row Rail typel+ rail type2 (1)Row, (9)Portrait (4)17' a (1)Row, (7)Portrait (4)14' b (5)Rows, (5)Portrait (2)14' (2) split 14' C (1)Row, (4)Portrait (2)17' d e- 1-* b 282 1/4" ► IFC 605.11.1 Exception for pathway requirements, If less than 2:12 pitch Net Meter S, l Y�A, JQ��4 A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U a � � o 00 E fV �Ma—'� (O In U Eo ru �Q VD o-a vi ^� 1 0 o O E L. a;:1- In w co REVISIONS Rev. #: IDate: Designed by: Tyler M. Project Manager: Will MacArthur (206)307-1741 Current Date:Jan 29. 2024 A2 Roof Layout SIDE VIEW (PORTRAIT TILT KIT PV MODULE RACKIN( u1:1u1 W-110: z•1•12 DENSDECK OR COVERBOARD (OPTIONAL) INSULATION ASSEMBLY (OPTIONAL) 48" Net Meter m�1 ROOF DECK M 15° N 36" I ROOF DECK A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 ANCHOR THIS DRAWING CONSTITUTES THE 00 CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT HOT AIR CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN WELD NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. �f14 U CTU RAL rENERS U a M � � o 00 E N �Ma-'� ro Ln U Eo ru wQ ,� ._ Vp ova' vi -a ^� 1 0 o O E L. a":1: Ln w co ,--I REVISIONS Rev. #: I Date: Designed by: Tyler M. Project Manager: Will MacArthur (206)307-1741 Current Date:Feb 12, 2024 A4 Racking PV Single Line String 1 11 modules String 2 10 modules String 3 9 modules String 4 8 modules String 5 7 modules 0 EEquipment Schedule IN u A u A u Generation Panel Bus: 125A Location: Exterior Ref. Category Equipment QTY 1 Modules REC410AA Pure 45 2 Inverters Enphase IQ8M-72-M-US 45 3 Jbox JBox 2 4 Loadcenters MLO, 125A, 240V, 1ph, Nema 3R, Surface, 12 space (min.) 1 5 Disconnect 100A 600V 2 Pole I Heavy Duty, No Fuse, Lockable 1 Breakers 2p20A 5 Monitoring Enphase IQ Monitoring 1 Misc. Enclosure for IQ Gateway NEMA 3 1 0 Conductor Schedule nverter Specs Watts u Output AC Voltage #of Inverters OCPD Branch ll Enphase IQ8M-72-M-US 325 1.35 240 45 20 ****N/A**** 0 0 0 0 0 ****N/A**** 0 0 0 0 0 Module Specs Watts w Imp vmp voc Isc REC410AA Pure 410 9.61 42.7 49 10.35 Temp. Adjusted 0 0 38.9 52.8 0 Summary Distance (ft) Current @125% Operating Voltage Voltage Drop V. Drop (total) A (2)#12 CU, (1)#6 EGC, Q Cable, AIR 46.2 18.56A 240V 0.62% 1.85% B (2)#12 CU, (1)#10 EGC, QCable, AIR 6 18.56A 240V 0.15% C (6)#10 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) 25 18.56A 240V 0.38% D (4)#10 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) 35 13.5A 240V 0.39% E (2)#4 CU, (1)#8 N, (1)#8 EGC, THWN-2, 1"EMT(min) 10 75.94A 240V 0.16% F (2)#4 CU, (1)#8 N, (1)#8 EGC, THWN-2, 1"EMT(min) 10 75.94A 240V 0.16% Storage Single Line F 0 Equipment Schedule A Bus Rating: 100A v^ Loads: 50A EV Charoer Ref. Category Equipment QTY 1 Gateway Tesla Backup Gateway2: Service Rated 1 Breakers 200A Main Breaker (Eaton CSR2200N) 1 Misc. Tesla 200A Internal Panelboad Kit 1 Breakers 2p80A, 2p60A 2 Battery Tesla Powerwall 2, 13.5 kWh 2 Misc. Powerwall Stack Kit 1 3 Loadcenters MLO, 125A, 240V, 1ph, Nema 3R, Surface, 4 space (min.) 1 Breakers 2p30A, 2p30A 4 Disconnect 60A 600V 2 Pole I Heavy Duty, No Fuse, Lockable 1 5 LoadCenters MLO, 100A, 240V, 1ph, Nema 1, Flush, 8 space (min.) 1 Breakers 2p100A 1 0 Conductor Schedule Service entrance conductors 4/0 XHHW-2 (L1 & L2) 2/0 XHHW-2 TESLA Gateway2 (N) 200A Internal Panelboard Solar OCPD:80A Battery OCPD:30A Battery OCPD:30A Circuit to Non backed up loads 100A max Net Meter i4- 4/0 XHHW-2 (L1 & L2) OOA/2p 2/0 XHHW-2 (N) #6 THWN-2 (EGC) Protected Loads Panel (Existing) Main Service Panel (1ph 240V Service) Main Breaker: 200A Bus Rating:200A i = A & R Scope = Existing or A&RSOLAR Others Scope 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 Inverter Specs Watts Output AC Voltage # of Inverters OCPD LAI J�d Tesla Powerwall 2 5000 1 24 240 2 30 Summary Distance (ft) Current @125% Operating Voltage Voltage Drop V. Drop (total) A (4)#10 CU, (2)#10 N, (1)#10 EGC, THWN-2, & com wire, 1"EMT(min) 10 30A 240V 0.25% 0.45% B (2)#6 CU, (1)#6 N, (1)#10 EGC, THWN-2, & com wire, 1"EMT(min) 10 60A 240V 0.20% General Notes: Utility: SnoPUD 1. EGC Where exposed to physical damage will be #6AWG Bare CU 2. If installing conduit on the roof, maintain greater than 7/8" above the surface 3. NEC 690.12: Rapid Shutdown initiated by AC Disconnect THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT :ONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. r� Q O co c�M�� M O E� c�N� p �L�' a � U ro (6 O rl Vow 0 v7 �e "D O O ■^ O O E L Ln N 70 LU a� 00 REVISIONS Rev. #: Date: 1 3/15/24 Designed by: Tyler M. Project Manager: Will MacArthur (206)307-1741 Current Date:Mar 15, 2024 E1 Single Line Inverter Specs Enphase IQ8M-72-M-US ****NSA**** ****NSA**** Module Specs REC410AA Pure Temp. Adjusted MLPE or RSD? Equipment Mppt Input Module # Modules per String # Strings # of Mods per group # of Mods/inverter # of Inverters Total # of Modules PV Electrical Calculations Watts Output # of OCPD Total AC Comb. EGC AC Voltage Array Specs (Adjusted for Temaerature IWI ll Inverters Branch out.(A) OCPD AC 325 1.35 240 45 20 60.8 80 #8 1 nverter 0 0.00 0 0 0 Mppt Input 0 0.00 0 0 0 Amperage (Imp) W(a-t)ts IMPVVm Voc Isc Temp. Coef V(oc) (DC) Voltage (Vmp) 410 9.61 42.7 49 10.35 Max Voltage(DC) -0.24 #10 38.9 52.8 Max Amps (DC) ***Select*** Enphase IQ8M-72-M-US Enphase IQ8M-72-M-US Enphase IQ8M-72-M-U 1 2 3 4 1 2 3 4 1 2 3 REC410AA Pure REC410AA Pure REC410AA Pure 1 0 0 0 1 0 0 0 1 0 0 1 0 0 0 1 0 0 0 1 0 0 1 0 0 0 1 0 0 0 1 0 0 1 1 1 11 8 26 45 Enphase IQ8M-72-M-US Enphase IQ8M-72-M-US Enphase IQ8M-72-M-US 1 2 3 1 2 3 1 2 3 9.61 0.00 0.00 9.61 0.00 0.00 9.61 0.00 0.00 38.9 0.0 0.0 38.9 0.0 0.0 38.9 0.0 0.0 52.8 0.0 0.0 52.8 0.0 0.0 52.8 0.0 0.0 10.35 0.00 0.00 10.35 0.00 0.00 10.35 0.00 0.00 s 4 Max Array Power(STQ 18.45kW DC Max Continuous AC Power: 14.625kW AC Interconnection Calcs Main Breaker 200 Bus Bar 200 Max PV OCD Allowed 40 PVOCPD Device Used 80 Tap or Breaker? Breaker Site Conditions ASHRAE Site: Seattle Low Temp (°F) 19 High 2%Temp (°F) 84 High 0.4%Temp (°F) 91 Ref. Conductor Description Distance AL CU Wire Gauge QTY Phase Neutral Neutral EGC (AWE) Wire Type Conduit Min. Conduit 90°C Rating Temp Correct. Fill Derate Derated 75°C Rating Current Operating Voltage Drop ft Conductors AWe QTY Type Ampacity 125% I Voltage A Microinverter Branch 46.2 CU #12 2 N/A N/A #6 QCable AIR N/A 30 1 100% 30.00 25 18.6 240 0.62% B Branch to Jbox 6 CU #12 2 N/A N/A #10 QCable AIR N/A 30 1 100% 30.00 25 18.6 240 0.15% C Jbox1 to Combiner 25 CU #10 6 #8 1 #10 THWN-2 EMT 0.75" 40 1 80% 32.00 35 18.6 240 0.38% D Jbox2 to Combiner 35 CU #10 4 #8 1 #10 THWN-2 EMT 0.75" 40 1 80% 32.00 35 13.5 240 0.39% E Combiner to Disco. 10 CU #4 2 #8 1 #8 THWN-2 EMT 1" 95 1 100% 95.00 85 75.9 240 0.16% F Disco. To Interconnect 10 CU #4 2 #8 1 #8 THWN-2 EMT 1" 95 1 100% 95.00 85 75.9 240 0.16% G H I J DC Voltage Drop 0.00% AC Voltage Drop 1.85% Total Voltage Drop 1.85% &ffl. A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U Ma O � M O Ln 00 E N -0 M �� rru Ln U Eo>Q Ln G� >C) 0 O o .O � E L. Ln a� w co REVISIONS Rev. #: Date: 1 1 3/15/24 Designed by: Tyler M. Project Manager: Will MacArthur (206)307-1741 Current Date:Mar 15, 2024 E2 Electrical Calculations Typical Placards Custom Placards A) NEC 2020 690.13 & 691.15 B) NEC 2020 705.12 (13)(3)(2) C) Utility Requirement D) Utility Requirement (Utility -Owned) D) A&R Solar Requirement (Customer - Owned) E) A&R Solar Requirement * if combiner used F) NEC 2020 690.13 (B) I) NEC 2020 690.31 (D)(2) K) NEC 2020 690.13 (B) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SOLAR ELECTRIC PV PANELS SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY L) NEC 2020 690.56 (C) Located on or no more than 3' from the service disconnecting means to which the PV system is connected O) A&R Solar Requirement * if multiple inverters IAWARNING DUAL POWER SOURCEI SECOND SOURCE IS PHOTOVOLTAIC SYSTEM P) NEC 2020 705.12(C) & 690.59 IF ` • D• NOT INSTALL ADDITIONAL LOADS IN THIS PANEL R) AHJ Requirement * if combiner used S) NEC 2020 230.85(1) T) NEC 2020 230.85(3) PLACARD SPECS G) NEC 690.54 MAX AC OUTPUT CURRENT: 14.85 A AC OPERATING AC VOLTAGE: 240 V AC Letter Height: 1/8" Maintain 1/4" border Red / White G) NEC 690.54 MAX AC OUTPUT CURRENT: 13.50 A AC OPERATING AC VOLTAGE: 240 V AC MAX AC OUTPUT CURRENT: 12.15 A AC OPERATING AC VOLTAGE: 240 V AC ... - G) NEC 690.54 MAX AC OUTPUT CURRENT: 10.80 A AC OPERATING AC VOLTAGE: 240 V AC - MAX AC OUTPUT CURRENT: 9.45 A AC OPERATING AC VOLTAGE: 240 V AC A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT � OR THE INFORMATION DISCLOSED HEREIN Q I I/ NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. 3 Branch of 11 (1) for each PV load center, Disconnect, MSP/uostrea m 1 Branch of 10 1 Branch of 9 1 Branch of 8 1 5 M Ln E N O L. Ln la Co N M O 00 - M 4-+ ON ro Ln U) E p w Q fu ,--I .0 U) oiOC Y ON M O .� E W Branch of 7 REVISIONS Rev. #: Date: 1 3/15/24 Designed by: Tyler M. Project Manager: Will MacArthur (206)307-1741 Current Date:Mar 15, 2024 G4 Placards J) NEC 2020 690.56 (C)(2) Standard Storage Placards Label Location: (BLC) Label Location: (GP) Label Location: (BLC) Label Location: (BLC,MSP,NM) NEC 705.12(C) For storage only projects Label Location: (TG if outside, service disconnect breaker if TG is inside) NEC 230.85 BLC - Backup Load Center GP - Generation Panel MSP - Main Service Panel NM - Net Meter TG - Tesla Gateway Label Location: (BLC,MSP,NM) NEC 705.12(C) For PV+storage projects Label Location: (BLC) NEC 705.12(B)(3)(3) Label Location: (TG) Label Location: (GP) Label Location: (Battery breaker or battery disconnect) NEC 706.15(C) Custom Storage Placards &*41.IPA� A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 CAUTION: POWER TO THIS SERVICE IS ALSO SUPPLIED FROM SOLAR PV AND ENERGY STORAGE SYSTEM SOURCES WITH DISCONNECTS LOCATED AS SHOWN: PV I N PINE ST. Directory Placard Qty. 1 THIS DRAWING CONSTITUTES THE CONFFIDENTIAL INFORMATION OFA&R SOLAR AND ITS RECEPTOR POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATTION DISCLOSED HERE IN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HERE IN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. M N O ('M O G) O -0 M � M (% ra Ln U Ec � ro '0-1 O Y O p� .r, O N .� 0 0 L N w a AY(S) REVISIONS Rev. #: I Date: SOLAR AND BATTERY AC DISCONNECTS NET METER Designed by: Tyler M. PM: Will MacArthur (206)307-1741 Current Date:Jan 29, 2024 PV-G3 Placards &*41. A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. a e M Ln E N >� +U Vp ^� O L.Ln a� 00 0 00 -0 M 4- ON r0 Ln (n Eo �Q ru ��a vi ova' -a 1om o E _0 w REVISIONS Rev. #: Date: Designed by: Tyler M. Will MacArthur (206)307-1741 Current Date:Mar 22, 2024 G5 Equipment BOM Category Equipment QTY Notes Modules REC410AA Pure 45 Inverters Enphase IQ8M-72-M-US 45 Jbox JBox 2 Loadcenters MLO, 125A, 240V, 1ph, Nema 3R, Surface, 12 space (min.) 1 Disconnect 100A BOON 2 Pole � Heavy Duty, No Fuse, Lockable 1 Breakers 2p20A 5 Monitoring Enphase IQ Monitoring 1 Misc. Enclosure for IQ Gateway NEMA 3 1 ElectricalWork Tesla Wall Charger Install (wired to 60A breaker) 1 Breakers 2p60A 1 EV charger Breakers 2p20A 1 Breaker for IQ Gateway Enphase accessories Misc. Portrait Q cable 47 Enphase Q Cable Q-12-10-240 Misc. Terminator Caps 7 Q-TERM-10 Misc. Male Q Connector 11 Q-CONN-10M Misc. Female Q Connector 9 Q-CONN-10F IronRidge Racking BOM XR100 Black,l7' 6 XR100 Black,l4' 19 Kit, XR100 Bonded Splice BOSS 14 Universal Module Clamp, Black 106 Stopper Sleeve 30mm 32 Grounding Lug, Low Profile 8 Square -Bolt Bonding Attachment Hardware 97 1/4 x 3/4 Microinverter Bonding Hardware, T-Bolt 45 End Caps, 10 sets(package) XR100 2 U-Anchor 2400, Mill (Spacing: 48") 97 Fastener: #14 x 2-8" DF-#14 PH3 (8 /mount) 776 3/8-16 flange nut 97 15" Tilt Leg Kits 49