APPROVED ENG2024-0135 SEWER PERMITSEWER PERMIT
PERMIT NU '
EI
City of • • .
:01 1
IL
www.edmondswa.gov i
Description: SEWER - SPOT REPAIR AT THE 4 TO 6 TRANSITION ISSUED: 03/29/2024
Address: 7207 173RD ST SW EDMONDS WA 98026-5130
EXPIRES: 06/27/2024
Permit Subtype: PARTIAL LINE
Permit Type: SEWER Parcel Number: 00513100013919
REPLACEMENT
CONTACTS
NAME TYPE NAME ADDRESS PHONE
APPLICANT
NICOLE MARINEZ 21010 70TH AVE W, EDMONDS WA 98026-7202 (425)775-0201
CONTACT
MIKE'S PLUMBING & DRAIN 21010 70TH AVE W, EDMONDS WA 98026-7202 (425)775-0201
CLEANING
CONTRACTOR
MIKES PLUMBING/DRAIN CLEANING PO BOX 1535, EDMONDS WA 98020-1535 (425)775-0201
OWNER RONALD N & BARBARA C HARRELL 7207 173RD ST SW, EDMONDS WA 98026-5130
FEE INFORMATION A� I
DESCRIPTION AMOUNT PAID
CITY TECHNOLOGY FEE - PER PERMIT $45.00 $45.00
ENG - INSPECTIONS $126.00 $126.00
SIDE SEWER PERMIT - PARTIAL REPLACEMENT $126.00 $126.00
REQUIREMENTS
REQUIREMENT TYPE NOTES
TRAFFIC CONTROL
Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION
Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its
departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney
fees by reason of granting this permit.
RELEASED BY: WHJ DATE: 03/29/2024
Printed: Friday, March 29, 2024 9:11:51 AM 1 of 2
SEWER PERMIT
PERMIT NU�IBEJ
City of Edmonds
www.edmondswa.gov • •
CONDITIONS
CONDITION TYPE
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD
ESC REQUIREMENTS
REQUIREMENTS.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to
indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and
agents from any and all claims for damages of whatever nature, arising directly or indirectly from the
HOLD HARMLESS
issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any
requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
INSP PRIOR TO BACKFILL
Call for all required inspections. All work shall be inspected prior to backfill.
SEWER AND WATER
MAINTAIN 10 FEET OF SEPARATION BETWEEN THE SANITARY SIDE SEWER AND THE WATER SERVICE
SEPARATION
LINE.
Owner/Contractor to provide Side Sewer asbuilt at final inspection. See City Handout E71 for
SEWER ASBUILT
requirements.
PLEASE REFER TO STANDARD DETAILS SS-200, SS-201 AND, SS-202. STANDARD DETAILS CAN BE
FOUND ON THE CITY OF EDMONDS WEBSITE. SDR35 WITH GASKETED FITTINGS IS REQUIRED FOR ALL
SEWER REPAIRS. FOR ANY REPAIRS WHERE THERE IS MORE THAN ONE STICK OF PIPE, A PRESSURE
SEWER REQUIREMENTS
TEST IS REQUIRED. WHERE LINING OR PIPE BURSTING WATER AND TV TEST IS REQUIRED. IF THE 4-6
TRANSITION IS ENCOUNTERED, A 6" CLEANOUT IS REQUIRED AT THE PROPERTY LINE. THE 6"
CLEANOUT SHALL HAVE A 12" CAST IRON LAMPHOLE COVER WITH 1/2 HEX BOLTS, GRIPPER TWIST
PLUG, AND A 24" CONCRETE COLLAR. AN AS BUILT IS REQUIRED PRIOR TO FINAL OF THE PERMIT.
Sound or noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on
SOUND AND NOISE
weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites and activities must comply with the noise
limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
PECTION TYPE
7S111DE
DATE
RESULT
NOTES
COMPLETE
R
X-2 ENGINEERING FINAL"
E-7 SEWER LATERAL
Printed: Friday, March 29, 2024 9:11:51 AM 2 of 2
.{ Qf EU,tfO
SIDE SEWER
PERMIT APPLICATION
jNc. l sa0
CONTRACTOR INFORMATION:
Company Name: Mi K:e'S Pl um hI n
Company Address:
o--t
Zip.
City: Q80 a-C9
State License # M I E S P D 95 Itil O
Expiration Date: 4
Site Contact: (2q (Xn t-h g q 1 n g
Phone#: aOC9v445to
Email #:InFo( mLKes✓JIUm to I n t�l1•Cor
City Business License #
WPM
PROPERTY INFORMATION:
Address: t7-3rd €dmondS, WA al8�a-en
Owner's Name: garba,rc- H CLrrt 41
Phone #: ,q �. �S q ol-q 3
FULL LINE REPLACEMENT SPOT REPAIR ❑PIPE BURST ❑RELINE (PERMALINE ONLY)
DESCRIPTION OF PROPOSED WORK (Be Specific):
ISSUANCE OF THIS PERMIT DOES NOT CONSTITUTE PERMISSION TO WORK ON ANY PROPERTY OTHER
THAN THAT OWNED BY THE SUBJECT PROPERTY OWNER.
CERTIFICATIONS NECESSARY FOR INSTALLATION METHODS ARE THE RESPONSIBILITY OF THE
CONTRACTOR PERFORMING SAID WORK.
1 REPRI SENT AND WARRANTTO THE CITY OF EDMONDS, IF REPAIR OF EXISTING SEWER EXTENDS TO AN
ADJACENT PROPERTY, I HAVE OW S PERMISSION TO PERFORM WORK ON THAT ADJACENT
PROPERTY.
SIGNATURE DATE 3
Cont gent
NO WORK SIIALL BEGIN PRIOR TO PERMIT ISSUANCE
CITY OF EDMONDS M BuildingPermit.com
Utilities Application #1465198 - SEWER REPAIR
Applicant
First Name Last Name Company Name
Nicole Marinez Mike's Plumbing & Drain Cleaning
Number Street Apartment or Suite Number E-mail Address
21010 70th Ave W nicole@mikesplumbinganddrain.com
City State Zip Phone Number Extension
Edmonds WA 98026-7202 (425) 775-0201
Contractor
Company Name
MIKES PLUMBING/DRAIN CLEANING
Number Street Apartment or Suite Number
21010 70th Ave W
City State Zip Phone Number Extension
Edmonds WA 98026-7202 (425) 775-0201
State License Number License Expiration Date UBI # E-mail Address
MIKESPD795MO 12/1/2025 BD9114ins nicole@mikesplumbinganddrain.com
Project Location
Number Street Floor Number Suite or Room Number
7207 173RD ST SW
City Zip Code County Parcel Number
EDMONDS 98026 00513100013919
Associated Building Permit Number Tenant Name
Additional Information (i.e. equipment location or special instructions)_
Work Location
Property Owner
First Name Last Name or Company Name
Ronald N & Barbara C Harrell
Number Street Apartment or Suite Number
7207 173RD ST SW
City State Zip
EDMONDS WA 98026-5130
Certification Statement - The applicant states:
I certify that I am the owner of this property or the owner's authorized agent. If acting as an authorized agent, I further certify that I have full power and
authority to file this application and to perform, on behalf of the owner, all acts required to enable the jurisdiction to process and review such application. I
have furnished true and correct information. I will comply with all provisions of law and ordinance governing this type of application. If the scope of work
requires a licensed contractor to perform the work, the information will be provided prior to permit issuance.
Date Submitted: 3/28/2024 Submitted By: Nicole Marinez
Page 1 of 2
CITY OF EDMONDS M BuildingPermit.com
Utilities Application #1465198 - SEWER REPAIR
Project Contact
Company Name: Mike's Plumbing & Drain
Cleaning
Name: Nicole Marinez Email: info@mikesplumbinganddrain.com
Address: 21010 70th Ave W Phone #: (425) 775-0201
Edmonds WA 98026-7202
Project Type Activity Type Scope of Work
Single Family Residential Utility Modification Partial Line Replacement
Project Name: SEWER REPAIR
Description of Work: Install up to 5ft of schedule 35 PVC with a 6in clean out to replace wye
connection.
Project Details
Structure Type
Single Family Dwelling
Project Information
Repair
Page 2 of 2